1. Heater Mode Normal E A Heater Mode Override Heater ON for 1 hour The heater will now stay on for 1 hour from the moment SELECT is pressed TIMER MODE The purpose of Timer Mode is to enable the householder to set certain times when the SmartVent heater can be active Normally the heater will come ON and go OFF under the control of the ceiling temperature and the minimum temperature 24 hours a day The Timer Mode allows the householder to limit this to one or two time periods during the day when the ceiling temperature is below the minimum temperature For example The ceiling temperature may fall below the minimum setting of 5 C between the hours of 3am and 7am In Normal Mode the heater if enabled would come ON during this time However if the householder only wants the heater on between 5 30am and 6 30am then the householder can set the Timer Mode to achieve this Maximum temp setting Above Minimum the heater is OFF Minimum temp setting Below Minimum temp setting Heater On only between 5 30am 6 30am in Timer Mode The mode has two timers and either one or both can be active This is designed for a morning and evening period Timer 2 OFF 11pm 9pm Timer 2 ON 7pm M Ceiling temp below Minimum gpm 7am Hj Timer Mode when Heater Active Time settings that the heater will operate only when the ceiling temperature drops below your minimum setting This example assumes that the
2. Press x3 Use the up and down buttons to step to Timer Mode HT Mode Timer Mode Set ON Time 05 30 The hours flash Use the up and down buttons to set the hour you want the heat transfer to come on Press SELECT The minutes flash Use the up and down but tons to set the minutes Press Select Set the hours and minutes as for the ON time and press SELECT The second time duration is then offered as a choice Use the up and down buttons to scroll through YES or NO and press SELECT Set Period 2 Yes Set the hours and minutes as for the first time period using the up and down buttons Press Select Set OFF Time 23 00 Set the hours and minutes as for the ON time and press SELECT to exit the mode To exit this mode return to Setup and Heat Transfr Mode SELECT Heat Transfer returns to Normal Operation Pressing Reset will also return the heater to Normal Operation Note For all heater modes pressing the Reset button defaults to Normal Heater Mode with the heater disabled Set ON Time 05 30 SYSTEM COMFORT TEMPERATURE When the Heat Transfer Mode has been enabled the controller uses the temperature sensed the system comfort temperature by the wall panel controller to control the transfer of hot air from this heated room When the comfort temperature is exceeded the system stops sourcing air from the ceiling cavity or outside the house and instead t
3. For example The room temperature may rise above the comfort setting of 25 C between the hours of 7am and 7pm In Normal Mode the heat transfer if enabled would come ON during this time However if the householder only wants the heat transfer ON only between 5 30pm and 6 30pm then the householder can set the Timer Mode to achieve this Above system comfort temperature the heat transfer is ON System Comfort Temp The mode has two timers and either one or both can be active This is designed for a morning and evening period Timer 1 OFF 11am Timer 2 ON 9am 5 30pm Timer 1 ON 7am J Room temp above system comfort temperature 9am 7pm HTimer Mode when heat transfer Active Time settings that the heat transfer will operate only when the room temperature exceeds the systems comfort temperature This example assumes that the room temperature is above the comfort setting from 9am to 7pm The heat transfer will only come ON if the room temperature is above the system comfort temperature and the time at which this occurs lies within the Timer periods set Timer 1 is set from 7am however since the temperature in the room is below the system comfort temperature settings the heat transfer will not come on until the temperature rises above the system comfort temperature in this case at 9am To enter Timer Mode ensure the heat transfer is enabled and go to the Setup Mode Heat Transfr Mode V
4. If the system RESET is required press the factory default settings for the minimum UP arrow and maximum temperature range the fan S A speed heater operation heat transfer and comfort temperature Reset is used when the householder needs Reset System to clear all previous settings and start over Yes Factory default settings are Then press SELECT Max Temp i Min Temp E SELECT Fan Heater Disabled Heater Mode Normal System Heat Transfer Disabled Reset Comfort Temperature 25 C Unlike the other buttons RESET requires a firm press in the centre of the circle until a beep confirms entry to this function This has been designed deliberately to prevent accidental RESET BE O rs Home Vent control ventilate for a healthy home Home Vent Active Reset System No If a system reset is not required press Ceiling 24 C SEREGI Room 20 C Note RESET does not function when System will return operation to Normal SmartVent is in the OFF mode Mode Home Vent Room 20 C fx 8 Lock Function At times it is useful to lock the keypad so that those little fingers or even bigger ones don t reconfigure your settings To prevent the keys from being accidentally pressed press and hold SELECT until the controller beeps x5 Keypad Locked Ceiling 22 C A Room 24 C The padlock icon amp shows the keypad is locked Pressing any key will have no effect except to
5. ceiling temperature is below the minimum setting from 9pm to 7am The heater will only come ON if the ceiling temperature is less than the minimum temperature and the time at which this occurs lies within the Timer periods set Timer 2 is set from 7pm however since the temperature in the ceiling space is above the minimum temperature setting the heater will not come on until the temperature drops below the minimum level In this instance 9pm To enter Timer Mode ensure the heater is enabled and go to the Setup Mode wi A Heater Mode Use the up and down buttons to step to Timer Mode Set ON Time 05 30 The hours flash Use the up and down but tons to set the hour you want the heater to come on Press SELECT Set ON Time 05 30 The minutes flash Use the up and down buttons to set the minutes Press Select Set OFF Time 06 30 Set the hours and minutes as for the ON time and press SELECT SELECT SELECT The second time duration is then offered as a choice Set Period 2 No Use the up and down buttons to scroll through YES or NO and press SELECT Set Period 2 Yes SELECT Set ON Time 19 00 Set the hours and minutes as for the first time period using the up and down buttons then Select SELECT Set OFF Time 23 00 Set the hours and minutes as for the ON time and press SELECT to exit the mode SELECT Screen 3 in Operating Mode shows Heater On Timer Mode To
6. display Keypad Locked To unlock the keypad press and hold SELECT until the controller beeps x2 Keypad Unlocked Ceiling 22 C Room 24 C Normal Operation is then restored and the padlock icon vanishes 9 Error Functions The SmartVent system monitors the communications and performance of the system If the SmartVent controller can not communicate with the ceiling unit the operational display flashes the error message every 5 seconds Error 1 No Comms If the temperature sensor in the ceiling unit fails the operation display flashes the following error message every 5 seconds Error 2 Ceiling Temp If the temperature sensor in the control panel fails the display flashes the following error message every 5 seconds Error 3 Room Temp Note Errors 1 and 2 are critical and with no communications or a failed ceiling temperature sensor the ceiling unit shuts down all relay control of the heater fan and damper Error 3 is non critical as the control panel temperature is not critical for the operation of the SmartVent However in all cases please contact SmartVent for technical support p 09 259 1662 e enquiry smartvent co nz SmartVent la NZ s Home Ventilation Specialists Distributed by Securimax a trading name of Simx Limited Customer Support p 09 259 1662 f 09 259 1661 PUB0225 iss 09 06 12 e enquiry smartvent co nz_ w www smartvent co nz
7. in the Heat Transfer Mode The Fan speed can still be changed to any of the 3 speed settings HEAT TRANSFER MODE Once the heat transfer is enabled this additional menu option is available Heat Transfer Mode allows the householder to choose between the three heater mode settings Normal Mode where the heat transfer is turned ON and OFF depending on the room temperature in relation to the system comfort temp e Override Mode where the householder can force the heat transfer ON for a certain time period irrespective of the room temperature and system comfort e Timer Mode where one or two time periods can be set by the householder to control the time the heat transfer comes on when the room temperature is above the system comfort Note To operate in the Override and Timer modes the real time clock must be set properly because these are time relative operating modes Refer to the Set Real Time Clock section OVERRIDE HEAT TRANSFER MODE This mode operates independently of the temperature in the room The householder can enter this mode if Heat Transfer is enabled and choose the heat transfer to turn on for either 1 2 4 or 6 hours from the time selected The heat transfer will stay ON for this period then turn OFF and Normal Mode will continue Press x3 Heat Transfr Mode HT Mode Normal HT Mode Override HT ON for 1 hour Use the up and down buttons to display the time duration for the
8. maximum To change or check the value of the minimum temperature enter the Setup Mode as follows pE A Press x3 System Min Temp Use the up and down buttons to increase or decrease the minimum temperature setting Note To activate this change in the minimum temperature setting you must press SELECT and the new temperature will be saved in memory To return to Operating Mode either wait for the 15 second timeout or press MODE Note Reset default for minimum temperature is 5 C FILTER STATUS The SmartVent controller monitors the filter and calculates the used To show the used enter the Setup Mode as follows E en A Press x4 Filter Status Filter 4 Used Filter Status To return to Operating Mode either wait for the 15 second timeout or press MODE When the filter is 100 used then it should be replaced Please phone the customer service number 09 259 1662 to be directed to your nearest outlet to purchase a replacement filter The SmartVent controller flashes the change filter light on the control panel when the filter needs replacing Change Filter Light flashing The first line on the display changes from the ceiling temperature to show a filter full message Filter Full Room 24 C Once a new filter has been installed it is a simple matter of resetting the filter usage to 0 through the Setup Mode When the filter has reached 100 an additional opera
9. no effect other than to illuminate the LCD if pressed e Power is still active on both the controller and ceiling unit To turn your SmartVent system ON press the ON OFF button and the following screens will appear E Home Vent Kf or Home Vent Active Active Gace Note Software version 2 XX o ware The XX denotes the version number Version 2 XX of the software 2 08 or greater E 4 Operating Mode SmartVent operates to the parameters set either by pushing the RESET button or those entered using the Setup Mode The 4 screens available for display in operating mode are shown below Ceiling 23 C Room 27 C A Normal Ceiling Vent Operation mHeat Fan3x 10 02am 25 01 07 Thu The default screen shows the temperature of the ceiling space and of the room that the controller is situated in Ceiling 23 C Room 27 C To show the other pages press either the up or down arrows as shown For the up button S E A The next screen shows where the SmartVent air is being drawn from the status of the Ceiling Vent mHeat Fan3x heater and the fan speed In this example the SmartVent air is drawing from the ceiling cavity the heater is disabled and the fan is operating at maximum speed 10 02am 25 01 07 Thu Real time clock showing time date and day E A Normal Operation Display indicating the SmartVent is operating in Normal Mode which means that the Maximum and the minimum tempera
10. Options applies to Non Summer Vent Models Press x 1 SV02 SV04 amp SVOG The Summer Function models will automatically draw air from outside when temperature is above your Maximum settings Maximum Temperature function Fan Mode Max option only for Use this function if you would like your system to Non Summer Models turn OFF once your ceiling temperature exceeds the maximum temperature so the system stops Bes pushing hot air into your home in summer Fei Minimum Temperature function Use this function if you would like your system Fan Mode to turn OFF once your ceiling temperature drops Disabled below the minimum temperature so the system stops pushing cold air into your home in winter Enable will turn the fan OFF if your minimum or E V maximum temperature goes beyond the ceiling temperature Fan Mode Disable will continue to operate as Normal Enabled To disable or enable the fan below minimum temperature To access the Fan Mode press Press x 1 WE MODE V Fan Mode Fan Mode Max option only for Non Summer Models Fan Mode Enabled The Fan icon will return to a rotating display when the ceiling temperature falls below the maximum temperature setting rises above the minimum temperature setting or the fan operation is restored to normal or the system is RESET Ceiling Vent mHeat Fan x The Fan Mode has been set Return to Operating Mode by pressing MODE If the
11. Override Heat Transfer Mode HT ON for 2 hours E A HT ON for 4 hours HT ON for 6 hours E A When a choice has been made press SELECT Screen three in Operating Mode will display Heat Transfr Heat Transfr Operation Mode To disable Override Mode enter Setup Mode amp scroll to heat transfer Mode option E e HT ON i for 1 hour Operation Pressing Reset will also return Heat transfer will return to Normal the heat transfer to Normal Operation Note Having entered an override time E this can be changed to a greater or The heat transfer will now stay on for 1 hour lesser duration by simply re entering from the moment SELECT is pressed Heat Transfer Mode selecting Override changing the time and selecting the new TIMER MODE period The purpose of Timer Mode is to enable the householder to set certain times when For example the SmartVent heat transfer can be active A four hour Override has been chosen but Normally the heat transfer will come ON the householder decides that this is too and go OFF under the control of the room long Enter Setup mode and step through to temperature and the system comfort Heat transfer Mode Select Override Mode temperature 24 hours a day The Timer and set the heat transfer for 1 hour Mode allows the householder to limit this to one or two time periods during the day when the room temperature is above the E mot V Press x3 system comfort temperature
12. Smartvent P NZ s Home Ventilation Specialists _ Digital Controller User Guide Manual www smartvent co nz ti Introducing SmartVent E Digital Control Panel 12x2 LCD Display with Backlight On Off Button Mode Button Enters the setup menu Select Button Confirms the menu selections made Up Down Arrows Use the arrows to scroll through the menus Orme Change Filter LED LED will illuminate when the filter needs changing O imn Reset Button This will reset the system to the factory settings CONTROL PANEL MAINTENANCE To clean the control panel gently wipe the surface with a moist tissue Do not spray Cleaning solutions or water onto the control panel It is not waterproof E Contents 1 General Information 0 cceseceesssnessssseeneseeeeeeseeseaes 1 How The SmartVent System Works cccccceeeeeeees 1 SmartVent Product Range cccccsececseseseseteeseeceeees 1 2 Quick Set Up GWG vss iccssarecnsssecunasesisasecusveswiavsiecanevannsad 2 3 Getting Starte E 3 ll ug Clg EE 3 d Operating MOUS siicisssssscsncicsincssisasesssnsssssraisasesiassensian 4 D SOU MOOG wiscteciarconvvspenuswesnsvevishcesemnearerdersuninecaswave 6 6 Setup Functions ere KE KEE KREE KREE EE Ke 8 System Fan Speed uu ccccccsesesesscsescsesecsescseecesseseenes 8 System Maximum Temperature 9 System Minimum Temperature cccccccsececeeseseeeees 9 Fiter STATUS 4 co teietegend
13. amp SVO6S lf Heat Transfer is installed and enabled To enter Setup Mode press the MODE button Ee x System Setup Use arrows to change settings amp select to enter kl To select any of the settings press SELECT button WE SELECT To exit the Setup Mode at any stage Either Press the MODE button and return to E Se Operating Mode Or Wait 15 seconds and the controller will time out to Operating Mode fx System Setup Use Be to change settings A se ect to enter E A A Mode Fan Speed E A System Comfort paaa Temp Note When using Mode settings you MUST press the SELECT button to confirm your decision If you do not press SELECT but return to Operating Mode by pressing MODE your changes will not be saved Heat Transfr PZ Mode N d E A Also if you wait for the timeout of 15 seconds then the changes will not Heat Transfr be saved Option E A E A System Max Temp System Min Temp E A Filter Status N b Heater Set Option Clock gt E A Si Service Mode i 6 Setup Functions SYSTEM FAN SPEED The SmartVent controller uses a multi speed motor to control the flow of filtered air into the house the Fan speed is determined by your Minimum and Maximum temperature settings Above Maximum temp Summer Models Vents from outside does not change fan speed Non Summer Models Will turn Fan Off if the Fan Mode Max setting is acti
14. e duration for the Override Heater Mode Timer modes the real time clock must be set properly because these are time relative operating modes Refer to the Set Real Time Clock section OVERRIDE HEATER MODE This mode operates independently of the E A temperature in the ceiling The householder can enter this mode if the heater is enabled and wishes to have the heater turn on for either 1 2 4 or 6 hours from the time selected The heater will stay ON for this period then turn OFF and Normal Mode will continue MODE E A Press x6 When a choice has been made press Heater Mode SELECT Heater Mode SmartVent will turn ON the heater at fan Normal speed 2 when the controller returns to Operating Mode E A Screen three in Operating Mode will display Heater On Override To disable Override Mode enter Setup Mode and scroll to Heater Mode option Heater Mode Heater Mode Normal Heater will return to Normal Operation Pressing Reset will also return the heater to Normal Operation Note Having entered an override time this can be changed to a greater or lesser duration by simply re entering Heater Mode selecting Override changing the time and selecting the new period For example A four hour Override has been chosen but the householder decides that this is too long Enter Setup mode and step through to Heater Mode Select Override Mode and set the heater for 1 hour Ee A Press x6
15. ee heater settings available when a heater is installed System calculates and displays the of the filter used An LED flashes when the filter needs replacing Customer service menu option Child lock facility Heat transfer mode and heater mode upgrades will activate once installed HOW THE SMARTVENT SYSTEM WORKS A SmartVent system lets you ventilate your home 24 hours a day SmartVent utilises any available warm air from your roof space SmartVent passes the air through a high grade F7 filter before gently distributing it around the home via diffusers set in the ceiling This continuous circulation of fresh drier air creates a positive pressure in the home therefore pushing damp stale air out of the home In Operating Mode the SmartVent system will display the ceiling temperature which determines the operation of the system and the room temperature for the consumers benefit SMARTVENT PRODUCT RANGE There are two main SmartVent Positive product variants The SmartVent controller will identify whether you have a summer function model on the display The Summer Function is used to draw cooler air from outside the house in the hotter summer months Display shows as follows for models Display shows as follows for models with Summer Function included without the Summer Function Home Vent ZE Home Vent Active Active fi 2 Quick Set Up Guide STEP ONE E y Set BE Clock Set the clock Press x2 The clock appears in 24 hour fo
16. er feature is installed or the Fan Mode becomes active for non summer models which turns the fan completely off When the roof space temperature exceeds the maximum temperature the controller opens the outside air damper or turns the fan off when Fan Mode is Active This temperature is adjustable up to 35 C and any setting that is at least 5 C greater than the minimum temperature Note The controller will not allow the maximum temperature to be set lower than the minimum To change or check the value of the maximum temperature enter the Setup Mode as follows Press x2 System Max Temp Max Temp lC Use the up and down buttons to increase or decrease the maximum temperature setting Note To activate this change in the maximum temperature setting you must press SELECT and the new temperature will be saved in memory To return to Operating Mode either wait for the 15 second timeout or press MODE WE Ge Note Reset default for maximum temperature is 30 C SYSTEM MINIMUM TEMPERATURE The controller uses the minimum temperature to control the point at which the fan speed drops to speed 1 if no heater is fitted or drops to speed 2 if a heater is fitted and enabled or drops to speed 1 if a heater is fitted but disabled This temperature is adjustable from 0 C to at least 5 C below the maximum temperature Note The controller will not allow the minimum temperature to be set greater than the
17. et ege dered ha ist i 10 Heater Option eet ege eege 11 Heater Mode ccccccccccscsesscseceessssecsessessensecsessenseses 12 Override Heater Mode ononenenessnensnerereieieiernreesrsrnren 13 Timer Mode c cccccsecccscssessessesscscessesessecoeesesseseeseenees 14 Customer Servi 17 Set Real Time ClOCK cecccecccescscsscsessesesseseceeseceesececnees 17 ap MOG Enar bial oneal nena 19 Heat Transfer Option ou cceccescscesesecscscseecetscsescseeeees 21 Override Heat Transfer Mode s ssnsiniensneneenninrnrnnen 22 Timer Mode 23 System Comfort Temperature c cccceeceesesecesseseeees 26 T Reset FUNGI EE 27 Bs LOG FUNG HON snccssancicnsanaxwsnedecsnwaeznscnecnmestenancaenenesseas 28 GD Eran FUNCTIONS sirsenis ERRE 28 SMARTVENT SUPPORT For further support with your SmartVent system please contact Technical Support p 09 259 1662 e enquiry smartvent co nz fi 1 General Information This SmartVent controller provides automatic control with an easy to follow menu you can simply relax while your SmartVent system is hard at work providing a healthy comfortable living environment for you and your family e Key system settings displayed in summary screens e Customisation of the system to individual preferences e SmartVent grows with you this controller will operate any upgrades you choose to add at a later date Maximum and minimum temperature range adjustable between 0 and 35 C Thr
18. exit this mode return to Setup and Heater Mode Heater Mode Heater Mode Normal SELECT SELECT E Heater returns to Normal Operation Pressing Reset will also return the heater to Normal Operation Note For all heater modes pressing the Reset button defaults to Normal Heater Mode with the heater disabled CUSTOMER SERVICE When the SmartVent is first installed it To assist with any questions you may have will be necessary to set the correct time regarding your SmartVent controller a date and day in Setup Mode Press MODE contact number is conveniently stored in button setup mode To access the help line press MODE Ee 7 Press x2 Ee vm A Press x6 Set Clock Press x7 If heater is installed and enabled Press x4 If heattransfer is installed and enabled Adjust time 14 42 33 The clock appears in 24 hour format of hours minutes and seconds The hours will blink Use the up and down buttons to set the correct hours then press SELECT BET nm or mo E Then the minutes will blink SET REAL TIME CLOCK Use the up and down buttons to set the The SmartVent controller has a real time correct minutes then press SELECT clock one to display the time but essentially to allow the householder to set the times the heater is active E Then the seconds will blink Use the up and down buttons to set the correct seconds then press SELECT Adjust date 30 01 07 The date page appears
19. in DD MM YY format Repeat the procedure as per the time page to set the correct date and press SELECT E Adjust day Tue Use the up and down buttons to set the day then press SELECT Set Clock The real time clock has been set Return to Operating Mode by pressing MODE or wait for timeout Note 1 In a power cut situation an on board battery keeps the clock operational 2 The setting of the clock is done in 24hr format but for readability the clock that is displayed on screen 2 of Operational Mode is a 12 hour format am pm 3 If for some reason such as touching the circuitry during installation the clock is upset then the display flashes Clock Error This can be fixed by resetting the clock as described on page 16 4 If a heater is installed enabled and in Timer or Override mode then a clock error disables the heater and these modes which rely on the clock are not functional until the clock is reset FAN MODE To disable or enable the fan above maximum Fan Mode controls the operation of the fan when temperature the ceiling temperature exceeds drops below the 0 access the Fan Mode press system maximum minimum temperature setting This feature is enabled when the user does not Se want the system to operate when the air in the E mm M ceiling space exceeds 35 C for example or conversely when the air in the ceiling drops below 10 C for example Fan PLEASE NOTE Mode Max Temp Setting
20. maximum temperature threshold has been exceeded then the Normal Operating Mode shows the fan icon as stationary amp no fan speed number In the Normal setting the fan continues as normal when the ceiling cavity temperature rises above your maximum temperature setting HEAT TRANSFER OPTION This mode is used to enable or disable the heat transfer of air When enabled and when your set comfort temperature is exceeded the system stops sourcing air from the ceiling cavity or outside the house and instead transfers excess warmed air from the heat source room to the other SmartVent outlets in your home To enable heat transfer enter Setup Mode MODE A Press x8 Heat Transfr Option Press x8 if heater is disabled or x9 if heater is enabled Heat Transfer is now enabled Return to Operating Mode by pressing MODE or 15 second timeout You will now need to set your Comfort Temperature If a heat transfer kit is not installed the following screen will be displayed when you press SELECT I Heat Transfr l no heat transfer option ph 09 259 1660 C This informs the householder that they will need to phone customer service to purchase the Heat Transfer Upgrade Kit When the system is in heat transfer mode the Operating screens will show as follows Transfr Vent mHeat Fan3x Heat Transfr Operation Please note The heater icon will show m as the heater will always be disabled
21. ransfers excess heated air from the controller room to other outlets in your home When the air temperature in the controller room reaches the pre set comfort temperature the system will automatically start functioning in the Heat Transfer Mode When the temperature in the controller room drops 1 C below the preset comfort level the system reverts back to a standard SmartVent configuration Note The default setting and reset setting for the system comfort temperature is 25 C This temperature is independent on the systems maximum and minimum temperatures The comfort temperature range you can choose from is 0 C 35 C To change or check the value of the comfort temperature enter the Setup Mode Press x2 pE Vi System Comfort Temp Note Heat Transfer Mode has precedence over minimum and maximum temperature settings Comfort Temp Te Use the up and downbuttons to set your desired comfort temperature then press SELECT Note To activate this change you must press SELECT and the new temperature will be saved in memory To return to Operating Mode either wait for the 15 second timeout or press MODE Note Your controller must be in the heat source room to read the comfort temperature and act accordingly This system will allow your warmed room to reach your comfort temperature before it starts transferring the excess heat fx 7 Reset Function reset This is used to restore the
22. rmat of hours minutes and seconds Use the up and down arrows to set the hours and minutes See page 17 for more details STEP TWO 2 System Set e maximum E A Max Temp temperature Press x2 What this does If a summer feature is installed it will draw air from outside above this temperature if not you can choose for the system to turn off above this temperature by setting the fan mode See page 9 for more details STEP THREE System Setthe minimum KE A Min Temp temperature Press x3 What this does If a heater is installed it activates below this temperature if not the fan speed will drop to low speed See page 9 for more details Settings Summer Winter Default Page Ref Maximum Temp 22 35 30 8 Minimum Temp 12 12 5 8 9 Heat Transfer disabled 23 25 20 24 WITH A HEATER installed see page 10 WITH HEAT TRANSFER installed see page 20 ft 3 Getting Started ON OFF BUTTON This button turns the SmartVent controller ON and OFF When the SmartVent is OFF the display shows either Home Vent Home Vent OFF ve OFF If the model purchased includes a summer function then the controller will display a flashing sun icon Note e All relays in the ceiling unit are turned OFF but the motor damper assembly and heater should be treated as liveZ at all times e The controller and the ceiling unit continue to communicate but remain passive in operation e The other buttons will have
23. se note The heater icon will show m if the heater is disabled and also if the heater is enabled but not operating If the heater is enabled and the ceiling temp drops below your set minimum temperature Screen 2 in the Operating Mode would show Ceiling Vent mHeat Fonds Note The heater icon flashes on then off whilst the heater is ON The fan speed automatically adjusts to medium 2 speed to ensure sufficient air passes over the heater element The fan speed can not be adjusted in Heater Mode The fan speed can be changed in Setup Mode but this change will not take effect until the ceiling temperature rises above your minimum temperature setting HEATER MODE Once the heater is enabled this additional menu option is available Heater Mode allows the householder to choose between the three heater mode settings e Normal Mode where the heater is turned ON and OFF depending on the ceiling temperature in relation to the minimum temperature e Override Mode where the householder DES Mode can force the heater ON for a certain time eater Mode period irrespective of the ceiling Override temperature and minimum temperature setting e Timer Mode where one or two time periods can be set by the householder to control the time the heater comes on when the ceiling temperature is below the minimum temperature setting Use the up and down buttons to display the Note To operate in the Override and tim
24. tion becomes available in the Setup Mode to reset the filter Press x5 A Reset Filter Timer Reset Filter Timer No Use the up and down buttons to toggle between yes and no Filter Status Filter 0 Used Note Once the filter timer has been reset the Reset Filter Timer page is removed until the filter is full again The timer calculates usage of the filter based on the fan speed A SmartVent system operating on low speed will take approx 1 2 years before reaching 100 filter usage Personal fan speed preferences will affect the filter usage rate HEATER OPTION This option allows the householder to enable or disable the heater if installed Note For the heater to work the heater must first be enabled The reset default setting is for the heater to be turned OFF To enable the heater enter Setup Mode A Press x5 Heater Option Heater m Disabled Heater u Enabled Note The heater icon changes from tom Heater is now enabled in Normal Mode Return to Operating Mode by pressing MODE or 15 second timeout If a heater is not installed the following screen will be displayed when you press SELECT Heater 00 heater ph 09 259 1660 This informs the householder that they will need to phone customer services to purchase the heater option In the Operating Mode the screens will show as follows Ceiling Vent mHeat Fan3x Normal Operation Plea
25. ture setting determine the fan speed and whether the air is vented from the ceiling cavity or the outside If the Heater is in Override Mode the display will show Heater ON Override If the Heater is set to Timer Mode the display will show Heater ON Timer Mode And if the SmartVent Heat Transfer Mode is operating the display will show Heat Transfr Mode Push the up button to return to the default display screen Note The display illuminates on the first press of a button but no action is taken until the second press of any button After 15 seconds if the up or down buttons are not pressed the controller reverts to the default display E 5 Setup Mode The Setup Mode allows you to customise the SmartVent operational parameters to your individual requirements Setup Mode also provides information on filter usage customer service clock settings The following menu options are available System Fan Speed System Maximum Temperature System Minimum Temperature Filter Status Heater Option Heater Mode Customer Service Set Clock Heat Transfer Option Heat Transfer Mode System Comfort Temp if heat transfer is installed and enabled Fan Mode Setup Heater Mode is displayed only if the heater is installed and Enabled in the Heater Option Fan Mode max option only applies to SmartVent models excluding Summer Function SV02 SV04 A SVO6 It does not apply to Summer Vent models SV02S SV04S
26. ve otherwise does not affect fan speed Maximum temp setting Minimum temp setting Below Minimum temp No heater or heater disabled changes to fan speed 1 or turn off if fan mode min is enabled Heater enabled changes to fan speed 2 Ceiling Temperature When the ceiling temperature drops below the minimum temperature the fan speed automatically sets to fan speed 1 if the heater is disabled or no heater is installed or speed 2 if the heater is enabled The controller uses a number 1 2 or 3 to represent low medium and high speeds and a rotating icon on screen one of Operating Mode to represent a fan running at speed E A System Fan Speed The display will indicate the current Fan speed for example Speed 2 Use the up and down buttons to alter the fan speed for example to change from displayed Medium speed 2 to high 3 press the button once Fan Speed High 3 To activate this change in fan speed press SELECT and the new fan speed is saved in memory Once SELECT is pressed the display returns to Setup Mode System Fan Speed Either press MODE or wait for 15 second timeout to return to Operating Mode Ceiling 24 C Room 20 C Or use the up and down buttons to step forward or backward to another setup selection SYSTEM MAXIMUM TEMPERATURE The controller uses the maximum temperature to control the point at which outside air is vented into the house if the summ

Download Pdf Manuals

image

Related Search

Related Contents

AXIS 231D/232D Network Dome Camera Installation Guide  Sunbeam WF6000 User's Manual  Brodit Passive Holder,Tilt Swivel  Weider WEBE2998 User's Manual      Sunbeam 6013 Blender User Manual  Manhattan 475716 notebook accessory  Hembry Creek M-ESSENCE-30SE Installation Guide  Planet Technology VIP-150T Telephone User Manual  