Home
Quick Start Guide - Lacon Electronic GmbH
Contents
1. Flashing Transmitting or receiving data ACT stands for ACTIVITY Physical Ports This switch provides e Eight 10 100 1000Base TX ports e Seven 10 100 1000Base TX ports one combo port e Six 10 100 1000Base TX ports two combo ports lt Note gt Combo port Either 1000Base SX LX port or 10 100 1000Base TX port CONNECTIVITY e RJ 45 connectors e SC connector on 1000Base SX LX fiber port Industrial Ethernet Switch Installation This chapter gives step by step instructions about how to install the switch Selecting a Site for the Switch As with any electric device you should place the switch where it will not be subjected to extreme temperatures humidity or electromagnetic interference Specifically the site you select should meet the following requirements The ambient temperature should be between 20 to 60 degrees Celsius The relative humidity should be less than 95 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards Make sure that the switch receives adequate ventilation Do not block the ventilation holes on the switch The power outlet should be within 1 8 meters of the switch 12 Industrial Ethernet Switch DIN Rail Mounting Fix the DIN rail attachment plate to the back panel of the switch Installation Place the switch on the DIN rail from above using the slot Push the front of the switch toward the mountin
2. this manual you will find e Features on the switch e illustrative LED functions e Installation instructions e Specifications Industrial Ethernet Switch Table of Contents QUICK START GUIDE PHYSICAL DESCRIPTION The Terminal Block and Power inputs The 1000Base T and 1000Base SX LX Connectors The Port Status LEDs FUNCTIONAL DESCRIPTION ASSEMBLY STARTUP AND DISMANTLING PREFACE TABLE OF CONTENTS PRODUCT OVERVIEW HARDENED GIGABIT ETHERNET SWITCH PACKAGE CONTENTS PRODUCT HIGHLIGHTS Basic Features FRONT PANEL DISPLAY PHYSICAL PORTS INSTALLATION SELECTING A SITE FOR THE SWITCH DIN RAIL MOUNTING WIRING DIAGRAM CONNECTING TO POWER 12VDC DC Jack Redundant DC Terminal Block Power Inputs Alarms for Power Failure CONNECTING TO YOUR NETWORK Cable Type amp Length Cabling SPECIFICATIONS APPENDIX A CONNECTOR PINOUTS CO U DR RRO jm O 12 Industrial Ethernet Switch Product Overview Hardened Gigabit Ethernet Switch Package Contents When you unpack the product package you shall find the items listed below Please inspect the contents and report any apparent damage or missing items immediately to your authorized reseller This Switch User s Manual External power adapter amp Power Cord Optional Ay iG Industrial Ethernet Switch Product Highlights Basic Features Meets IEC61000 6 2 EMC Generic Standard Immunity for industrial environment Suppor
3. Industrial Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the hardened Gigabit Ethernet Switch Capable of operating at temperature extremes of 20 C to 60 C this is the switch of choice for harsh environments constrained by space Physical Description The Terminal Block and Power inputs l oo 0 0 9 O O y L r gaat 4 Power Input Assignment Power3 12VDC 3A DC Jack 1 5A 24VDC 9 32VDC PowerGround _ _ 9 32vDC Terminal Block 1 5A 24VDC 9 32VDC Earth Ground Relay Output Rating OVC 1A Warning signal disable for following 1 The relay contact closes if Power1 and Power2 are both failed but Power3 on 2 The relay contact closes if Power3 is failed but Power1 and Power2 are both on Power2 Power1 Industrial Ethernet Switch DC Terminal Block Power Inputs There are two pairs of power inputs can be used to power up this switch Redundant power supplies function is supported The 1000Base T and 1000Base SX LX Connectors 1 The 1000Base T Connections The following lists the pinouts of 1000Base T port Pin Label w Oo mo A Q gt B 4 oo 4 g 2 The 1000Base SX LX Connections The fiber port pinouts The Tx transmit port of device is connected to the Rx receive port of device Il and the Rx receive port of device to the Tx transmit port of device Il 3 The WDM 1000Base LX Connecti
4. es from 20 C to 60 C e Supports DIN Rail or Panel Mounting installation Assembly Startup and Dismantling e Assembly Place the switch on the DIN rail from above using the slot Push the front of the switch toward the mounting surface until it audibly snaps into place e Startup Connect the supply voltage to start up the switch via the terminal block or DC JACK Industrial Ethernet Switch e Dismantling Pull out the lower edge and then remove the switch from the DIN rail Industrial Ethernet Switch Preface A member of the growing family of rugged switches this switch addresses a need for a smaller switch This switch provides an affordable solution for rugged and outdoor environment transportation road side cabinet industrial floor shop multitenant dwellings or Fiber To The Home FTTH applications Capable of operating at temperature extremes of 20 C to 60 C this is the switch of choice for harsh environments constrained by space Plug and Play Solution The switch is a plug and play Gigabit Ethernet Switch in compact size It doesn t have any complicated software to set up This manual describes how to install and use the hardened Gigabit Ethernet Switch This switch integrates full wire speed switching technology This switch brings the answer to complicated hardened networking environments To get the most out of this manual you should have an understanding of Ethernet networking concepts In
5. g surface until it audibly snaps into place Removal Pull out the lower edge and then remove the switch from the DIN rail 13 Industrial Ethernet Switch Wiring Diagram Power 1 ne Terminal iN Power 3 Block Block DC Jack 9 32VDC 8 32VDC Earth Ground Output Field Wiring Terminal Use Copper Conductors Only 60 75 C 14 24 AWG torque value 4 5 Ib in RJ 45 Connector Fiber Optic Cable Twisted Pair Copper Wire 14 Industrial Ethernet Switch Connecting to Power Redundant DC Terminal Block Power Inputs or 12VDC DC Jack 12VDC DC Jack Step 1 Connect the supplied AC to DC power adapter to the receptacle on the topside of the switch Step 2 Connect the power cord to the AC to DC power adapter and attach the plug into a standard AC outlet with the appropriate AC voltage Redundant DC Terminal Block Power Inputs There are two pairs of power inputs can be used to power up this device You only need to have one power input connected to run the switch Step 1 Connect the DC power cord to the plug able terminal block on the switch and then plug it into a standard DC outlet Step 2 Disconnect the power cord if you want to shut down the switch 15 Industrial Ethernet Switch Alarms for Power Failure Step 1 There are two pins on the terminal block are used for power failure detection It provides the normally closed output when the power source is active Use
6. ons The fiber port pinouts Only one single mode optical fiber is required to transmit and receive data Industrial Ethernet Switch 10 100Base TX i Steady A valid network connection established Link ACT Green Transmitting or receiving data Flashing ACT stands for ACTIVITY 1000Base T SX LX Link ACT Steady A valid network connection established Orange Flashing Transmitting or receiving data ACT stands for ACTIVITY Industrial Ethernet Switch Functional Description e Meets IEC61000 6 2 EMC Generic Standard Immunity for industrial environment e Supports IEEE802 3 802 3u 802 3ab 802 32 802 3x 802 1p Auto negotiation 10 100 1000Mbps Full Half duplex Auto MDI MDIX e 1000Base SX LX Multi mode Single mode or WDM Single mode SC type e EEE802 1p Queue Priority Support 4 priority queues e Supports 8192 MAC addresses Provides 1 125M bits buffer memory e Supports jumbo frame up to 9K Bytes e Alarms for power failure by relay output e Power Supplies Redundant 9 32VDC Terminal Block power inputs and 12VDC DC JACK with 100 240VAC external power supply For Use with Model UP0351E 12P as power jack supply source by Universal Micro Electronics Co Ltd e Field Wiring Terminal Use Copper Conductors Only 60 75C 14 24 AWG torque value 4 5 lb in e Operating voltage and Max Current consumption 0 6A 12VDC 0 3A 24VDC Power consumption 7 2W Max e Operating temperature rang
7. r 62 5um SMF 9 or10um Per unit Power status Power1 Power2 Power3 Per port 10 100Base TX Link ACT Green 1000Base T SX LX Link ACT Orange 58mm W x 110mm D x 135mm H 2 29 W x 4 33 D x 5 31 H 0 8Kg 1 76lbs Terminal Block 9 32VDC DC Jack 12VDC External AC DC required 0 6A 12VDC 0 3A 24VDC 7 2W Max 20C to 60 C 4 F to 140 F 40C to 85C 40 F to 185 F 5 95 non condensing UL508 EN60950 1 IEC60950 1 19 EMI EMS Environmental Test Compliance Industrial Ethernet Switch FCC Part 15 Class A EN61000 6 3 EN55022 EN61000 3 2 EN61000 3 3 EN61000 6 2 EN61000 4 2 ESD Standard EN61000 4 3 Radiated RFI Standards EN61000 4 4 Burst Standards EN61000 4 5 Surge Standards EN61000 4 6 Induced RFI Standards EN61000 4 8 Magnetic Field Standards EN61000 4 11 Voltage Dips Standards IEC60068 2 6 Fc Vibration Resistance IEC60068 2 27 Ea Shock IEC60068 2 32 Ed Free Fall 20 Industrial Ethernet Switch Appendix A Connector Pinouts Pin arrangement of RJ 45 connectors ASEAN IN N ZA Odo ae PSR N i IR SS NX i RJ 45 Connector and Cable Pins The following table lists the pinout of 10 100 1000Base TX ports 21
8. repare cable with corresponding connectors for each type of port in use lt Note gt To connect two regular RJ 45 ports between switches or hubs you need a straight or cross over cable Step 3 Consult the previous section for cabling requirements based on connectors and speed Step 4 Connect one end of the cable to the switch and the other end toa desired device Step 5 Once the connections between two end devices are made successfully turn on the power and the switch is operational 18 Industrial Ethernet Switch Specifications Hardened Gigabit Ethernet Switch Applicable Standards Switching Method Forwarding Rate 10Base T 100Base TX 1000Base T 1000Base SX LX Performance Cable 10Base T 100Base TX 1000Base T 1000Base SX LX LED Indicators Dimensions Net Weight Power Operating Voltage amp Max Current Consumption Power Consumption Operating Temperature Storage Temperature Humidity Safety 10 100 1000Base TX auto negotiating ports with RJ 45 connectors 1000Base SX LX fiber ports IEEE802 3 10Base T IEEE802 3u 100Base TX IEEE802 3ab 1000Base T IEEE802 3z 1000Base SX LX Store and Forward 10 20Mbps Half Full duplex 100 200Mbps Half Full duplex 2000Mbps Full duplex 2000Mbps Full duplex 148 80pps for 10Mbps 148 810pps for 100Mbps 1 488 100pps for 1000Mbps 2 pair UTP STP Cat 3 4 5 2 pair UTP STP Cat 5 4 pair UTP STP Cat 5 5e Up to 100m 328ft MMF 50 o
9. this as a dry contact application to send a signal for power failure detection Power Input Assignment 12VDC 3A DC Jack See 1 5A 24VDC 9 32VDC PowerGround 1 5A 24VDC 9 32VDC P 1 iii Power Ground _ Relay Output Rating 30 VDC 1A Relay Alarm Assignment Warning signal disable for following 1 The relay contact closes if Power1 and Power2 are gt FAULT both failed but Power3 on 2 The relay contact closes if Power3 is failed but Power and Power2 are both on Special note The relay output is normal open position when there is no power to the switch Please do not connect any power source to this terminal to prevent the shortage to your power supply 16 Industrial Ethernet Switch Connecting to Your Network Cable Type amp Length It is necessary to follow the cable specifications below when connecting the switch to your network Use appropriate cables that meet your speed and cabling requirements Cable Specifications Speed Connector Port Speed Cable Max Half Full Distance Duplex 10Base T RJ 45 10 20 Mbps 2 pair 100 m Cat 3 4 5 100Base TX RJ 45 100 200 Mbps 2 pair 100 m Cat 5 1000Base T RJ 45 2000 Mbps 4 pair 100 m Cat 5 5e 62 5um 1000Base LX S 10 20 or 50 km 17 Industrial Ethernet Switch Cabling Step 1 First ensure the power of the switch and end devices are turned off lt Note gt Always ensure that the power is off before any installation Step 2 P
10. ts IEEE802 3 802 3u 802 3ab 802 3z 802 3x 1000Mbps Full duplex 10 100Mbps Full Half duplex Auto Negotiation Auto MDI MDIX 1000Base SX LX Multi mode Single mode or WDM Single mode SC type IEEE802 1p Queue Supports 4 priority queues 8192 MAC addresses 1 125M bits buffer memory Full wire speed forwarding rate Supports jumbo frame up to 9K Bytes Alarms for power failure by relay output Power Supplies Redundant 9 32VDC Terminal Block power inputs and 12VDC DC JACK with 100 240VAC external power supply For Use with Model UP0351E 12P as power jack supply source by Universal Micro Electronics Co Ltd Field Wiring Terminal Use Copper Conductors Only 60 75 C 14 24 AWG torque value 4 5 lb in Operating voltage and Max current consumption 0 6A 12VDC 0 3A 24VDC Power consumption 7 2W Max 20C to60C operating temperature Hardened aluminum case Supports DIN Rail or Panel Mounting installation Industrial Ethernet Switch Front Panel Display Power Status Power1 Power2 Powers These LEDs come on when the switch is properly connected to power and turned on Port Status LEDs The LEDs display status for each respective port Industrial Ethernet Switch 10 100Base TX f Steady A valid network connection established Link ACT Green Flashing Transmitting or receiving data ACT stands for ACTIVITY 1000Base T SX LX Link ACT Steady A valid network connection established Orange
Download Pdf Manuals
Related Search
Related Contents
IBM eServer x3250 M3 G1101-2.26GHz 2MB 1GB manual de usuario Toshiba LX835-SP0267SM Sungale ID350AT User's Manual Page 1 Page 2 ーはじめに この取扱説明書は、 「スカイレシーパー」 の Procolor Picture King EF24-70mm F2.8L USM 使用説明書 Elgento E13005 coffee grinder Copyright © All rights reserved.