Home

camset33 - 2-channel video security door phone

image

Contents

1. the submonitor LED interphone when the interphone button is pressed the amber LED is on LED C2 when camera 2 is selected the green LED is on LED C1 when camera 1 is selected the red LED is on 10 Volume control controls chime volume 11 Brightness control adjust picture brightness monitor off means the display is off 12 Handset jack to connect the handset to the monitor 13 Speaker for chime call Installation lt I UW N Fe Mount the wall bracket 2 with the tapping screws provided Connect lead wires to terminal as shown in 2d on page 4 Fix the indoor unit 1 onto the wall bracket 2 Connect the AC plug 3 to the outlet Secondary indoor monitor units submonitors can be bought separately CAMSET33 SUB these have a different connection terminal configuration see 2d CAMSET33 2 GB b Outdoor Unit with Camera CAM6 included also available separately 1 CCD camera lens with automatic iris 2 Infrared LEDs allow you to identify the visitors in poorly lit areas 3 Speaker for chime and voice 4 Call button as the visitor presses the call button the picture appears on the indoor monitor and the indoor chime rings 5 Microphone to talk to the indoor unit Installation 1 Take the base panel 2 and fix it firmly on the wall 3 with tapping Screws 2 Connect lead wires to the terminals as shown in 2d on page 4 3 Attach the camera 1 to the
2. time approximately 150 seconds when the indoor unit is picked up there is approximately 150 seconds of time available before the units automatically shut down Monitor time approximately 30 seconds when outside camera is activated from inside there is approximately 30 seconds of viewing time before unit automatically shuts down 5 Door open function An electric DC door lock has to be purchased separately The indoor unit can be wired to activate the door opener 6 Installation location Carefully select a site to install the outdoor unit as it may be damaged by direct rainfall strong vibrations or excessive dust For optimum video display the unit should be installed where direct sunlight cannot reach it Inferior picture quality can also occur when the lens cover is scratched CAMSET33 1 GB 3 Components amp Installation a Indoor unit with monitor included 1 2 3 4 5 6 1 8 9 Phone hand set to communicate with visitors outside Monitor visitors appear through the outdoor camera lens Door release button press the button to unlock the door if an electric door lock is installed Camera 1 2 selection button press this button to switch from camera 1 to camera 2 and vice versa Monitor on off button press the ON OFF button to see who is outside press it again to turn the monitor off Interphone button when a submonitor is installed press this button to communicate with
3. CAMSET33 2 CHANNEL VIDEO SECURITY DOOR PHONE Ah Velermemn components 1 Introduction C 1 Thank you for buying the CAMSET33 Read this manual carefully before bringing the device into service This CAMSET33 consists of one indoor unit with monitor and one outdoor unit with camera with which you can see visitors and converse with them from inside your home without having to open your entrance door 2 Generalities amp Installation Tips 1 Activation of units When the call button of the outside camera is pressed the indoor units chime rings and the visitor s picture appears on the indoor units monitor When you ve visually identified the visitor and you wish to converse with him her lift the handset and converse The unit will remain activated for approximately 150 seconds before it automatically powers off To re activate for continued conversation push the ON OFF button 2 Activation of outside unit from inside unit Press the ON OFF button of the indoor unit at any time and the outdoor camera will be activated and Show the outside view 3 Interphone When 2 or more monitors are installed press the interphone button 6 to communicate with the other monitor s The amber LED lights up 4 Working time Call time approximately 30 seconds the picture automatically disappears if the indoor unit is not answered within approximately 30 seconds after the call button of the outdoor unit is pressed Talk
4. base panel and fasten it with one machine screw at the bottom c Outdoor Unit with Camera CAM12 optional 1 Infrared LEDs built in infrared LEDs allow you to identify visitors in poorly lit areas 2 CCD camera lens with automatic iris 3 Speaker for chime and voice 4 Call button as the visitor presses the call button the picture appears on the indoor monitor and the indoor chime rings 5 Microphone to talk to the indoor unit Installation 1 The junction box 3 must be fixed in the wall with concrete or silicon 2 Remove the upper and lower parts 4 of the front of the camera 1 using a flat screwdriver 3 Connect the wires to the terminals as shown in 2d on page 4 4 Fix the unit to the junction box with two hexagonal bolts 2 one at the top and A 4 gt one at the bottom using a hexagonal wrench not included 7 Pe ae 5 Reassemble the upper and lower parts of the front side g re Adjusting camera angle 1 Take the unit out of the junction box 2 When vertical adjustment is required move the control lever up or down CAMSET33 3 GB d Wiring 1 Be careful to connect indoor and outdoor units as indicated below 2 Two wires are required for each outdoor unit to be connected to the indoor unit 3 An additional two wires are required for each electric door lock to be connected to the indoor unit 4 Make sure that a separate power source is provided for each door lock NOTE Electric door
5. ck firmly inserted to indoor unit 5 Maintenance 63 Keep the units dry If water should get on them wipe it off immediately Water contains minerals that can corrode electronic circuits Do not store in hot or cold areas Extreme hot or cold temperatures can shorten the life of electronic devices and can even distort or melt certain plastics or may cause improper working Dropping can result in cracked circuit boards and cases and failure to operate Do not use or store in areas with high levels of dirt or dust as they may contaminate the electronics Do not use harsh chemicals cleaning solvents or strong detergents to keep your unit looking new You need only wipe it with a dampened cloth from time to time eared Nhe 5 GB 6 Specifications Monitor indoor unit Model OASE Voice Transmission 2 way communication Voice Transmission System Frequency modulation Camera outdoor unit Model AMG CAMI2 Microphone Sensitivity 56d0B Working Temperature 10 50 C 14 122 F Viewing Angle 92 110 CAMSET33 6 GB
6. lock is not supplied with the CAMSET33 MF oe Als dk MF k dh F EF Li di de di ED d T T a T 1 Pi 3 A i i if j 1 1 1 E VIDEO GND L1 L2 DT CMR CMRI ur ad ad hd Bee PP EI EI eal EI EA EA H DOOR LOCK CAMSET33 4 GB e Wiring diagram with secondary monitors 1 2 cameras can be connected to 4 monitors under parallel wiring 2 An additional 4 wires are required per secondary monitor 3 Make sure there s a Separate power source for the door lock 4 Only the main monitor will be connected with cameras and door lock 5 For better audio amp video use the cable as follows 1 Coax cable conductor use it for video connections 2 Coaxial cable shield use it for the GND connection 3 Wire 2EA use It for L1 and L2 connections 2 our 11 eee ieo EE 9 9 GND 9 GND ed CMR2 oe 7 L2 gt L2 L2 m ej foe Ae E ojo 4 L2 4 4 4 ale GND GND GND 3 3 3 OUT OUT OUT Ek El add 2 VIDEO 2 VIDEO VIDEO 1 VIDEO 1 N 1 IN 1 IN MAIN MONITOR SUBMONITOR SUBMONITOR SUBMONITOR CAMSET33 CAMSET33 SUB CAMSET33 SUB CAMSET33 SUB 4 Troubleshooting PROBLEM CHECKPOINT No picture on the monitor Is the AC plug firmly inserted into the power outlet Are the wires between the outdoor and indoor unit s firmly connected Volume is too low on calling tone Adjust the volume Monitor picture too dark or bright Adjust the brightness Video but no sound in the handset Is the handset ja

Download Pdf Manuals

image

Related Search

Related Contents

TANK-101B_BW_UMN_v1.02  Manuale di istruzioni  Kenroy Home 30438BRZ Installation Guide  - Datamax    varimed® Mobiliario médico auxiliar para  2468 フュートレック  Avis générales d`utilisation  Salt Palace Convention Center Hall A Hall B Hall C Hall  Wzzard Sensor Node User Manual - Industrial Networking Solutions  