1. NOTE If you encounter problems or have questions on the oiling and or assembly please contact Customer Support TROUBLESHOOTING Most issues identified below are resolved as the user becomes more adept using the device Should any of these issues persist contact our Customer Support toll free 866 692 6676 Should you experience abnormal discomfort excessive bruising or bleeding occur discontinue use of the device and consult your physician CAUSE No vacuum Air leak Check device for Test the system on a being created caused by poor air leaks Check smooth airtight surface in cylinder seal seal between tabletop or your hand device and tension which will verify system Keep the operation A strong cylinder steady vacuum should be Partial erection created in cylinder Rapid loss of erection once the cylinder is removed Pulling in of the scrotum skin Discomfort when pulling in foreskin Discomfort of penis during intercourse Redness irritation and or bruising Air leak caused by poor seal between tension system and cylinder Not enough pumping strokes Not waiting long enough between pumping action Too large tension system Too large tension system or too much lubricant on the tension system or penis Insufficient lubricant or too much foreskin Insufficient lubrication of partner Insufficient lubrication over pumping not used to a during pumping so
2. OTC CUSTOM USER S GUIDE IMPORTANT For best results read this manual prior to use TABLE OF CONTENTS System Description i Precautions 2 DOs and DON Ts Z First T me Users Practice Session 3 Finding The Right Tension System 3 Additional Tips 4 Instructions For Use 4 Cleaning Instructions OTC CUSTOM gt Cleaning Instructions Tension System 5 Periodic Oiling Instructions 6 In Depth Oiling And Assembly Instructions 6 Troubleshooting 9 11 SYSTEM DESCRIPTION The OTC OVER THE COUNTER CUSTOM Model 1002 is a Vacuum Erection Device VED intended for use by men experiencing difficulty in achieving and or maintaining an erection suitable for intercourse The OTC CUSTOM system consists of Vacuum Cylinder 1 Tension Systems 5 Two 2 oz Tube of Personal Lubricant 1 Storage Case 1 User s Guide The OTC CUSTOM Model 1002 is a light weight easy to use device comprised of two major components The components are Vacuum Cylinder and Tension System The tension system is applied to the base of the tube Then the user applies a small amount of personal lubricant to the opening of the tension system After lubricating the opening rest the tip of the non erect or flaccid penis in the opening of the tension system the user moves the sleeve up and down creating a vacuum or negative pressure The negative pressure draws the venous blood into the penis and the penis through the tension system into the cylind
3. DO NOT use the tension system as birth control or contraceptive e DO NOT use wrong oil silicone oil only to be used during periodic maintenance as it may decrease pump efficiency e DO NOT scratch or damage surface of device as it may decrease pump efficiency e DO NOT use the included silicone oil or petroleum based oil on the tension system as it will cause permanent damage to the tension system e DO use only a water soluble lubricant on the tension system e DO select the correct tension system ensuring comfort during intercourse e DO allow 60 minutes between uses of tension system e DO clean system after each use You do not have to take the system apart e DO store in a dry dark place e DO perform periodic cleaning every three to four months FIRST TIME USERS PRACTICE SESSION The practice session is designed to allow you to see how the system works and become accustomed to using it If time permits use the system twice a day as an exercise These exercises will increase blood flow strengthen the blood vessels and create healthier tissue within the penis resulting in firmer more rigid erections For the first 5 7 days practice using the largest tension system 30 Practicing allows you to achieve a much better erection before you attempt sexual activity During the practice session you will use the Vacurect to create an erection Each time you achieve an erection maintain the erection by leaving the
4. Vacurect in place for at least a to 2 minutes After the time has elapsed remove the cylinder and the tension system allowing the erection to subside Remember Take Your Time in Creating Your Erection during these sessions for the best results After the practice period you will want to try several tension systems to determine which tension system best maintains your erection If you are not familiar with using a vacuum erection device the tension system may feel unusual for the first few times This is normal FINDING THE RIGHT TENSION SYSTEM As a user of the OTC CUSTOM you must find the correct tension system size The correct size is based on personal comfort and maintaining a satisfactory erection for sexual activity Begin with the largest tension system work your way down to the tension system that is effective in maintaining the erection and most comfortable Always use the least constrictive tension system that will maintain a satisfactory erection Use the tension system as directed paying special attention to the DOs and DO NOTs identified previously ADDITIONAL TIPS USING THE OTC CUSTOM By practicing employing patience and adhering to the helpful tips the Vacurect will become an effective tool to treat your erectile dysfunction Tip 1 When using personal lubricant KY Jelly it is most effective to apply only a small amount to the funnel opening of the tension system Tip 2 Ensure t
5. and valve stoppers are in place as shown STEP 5 Apply OTC CUSTOM silicone oil to the oversized thinner and sleeve i thicker O rings C STEP 6 Place oversized thinner O ring in groove between valve amp dome stopper as shown System is now turned the other way STEP 7 Pinch the excess amount of O ring and place in narrow gap towards the dome stopper NOTE Excess amount is placed towards top of the cylinder Dome Stopper System is now turned the other way STEP 8 Slide the threaded end of the Sleeve over the top of the cylinder down over the dome stopper oversized O ring and valve stopper STEP 9 At this point verify the assembly looks as shown STEP 10 Push the outer sleeve down to the dome stopper STEP 11 Using a flexible material old credit card or other plastic material push the loop of the oversized O ring while at the same time turning the outer sleeve slightly until it slips in place STEP 12 Verify the oversized O ring slips in place and looks as shown STEP 13 Place the spacer ring so that it fits down in and flush with the pump sleeve STEP 14 Slide the black sleeve thicker O ring oiled onto the main cylinder behind the spacer ring STEP 15 Place the sleeve screw ring on the cylinder and hand tighten NOTE Do not over tighten STEP 16 Congratulations You have completed the oiling and assembly of your device
6. as not to break the seal between the cylinder and the tension system See above Use more strokes and GO SLOW Wait longer after pumping usually 10 15 seconds Use the next size down tension ring Use the next size down tension ring Make sure excessive lubricant is not on the scrotum skin Lubricate the penis and the foreskin if necessary Use a water soluble lubricant for sexual activity Use more lubrication slow the pumping action GO SLOW 10 maintained for at least 10 minutes See above 2 3 strokes should normally be enough each time and then pause Once accustomed to unit your erection should be able to be created within one to five minutes Wipe the excess lubricant from the scrotum with a dry washcloth Once the penis starts to be drawn into the cylinder remove the cylinder pulling the foreskin through the tension system replace the cylinder on the penis and the tension resume pumping Lubricate the penis and vagina as necessary Once you become accustomed to the tension system these issues will disappear Penis feels cold to partner Penis pivots on the base tension system being placed on the base of the penis Reduction of warm blood circulation The penis 1s rigid from the tension system to the tip which 1s two thirds of the penis length The other one third is in the body and not erect Use a warm washcloth to wa
7. causes the oil to seep onto the O RING Vacuum Tube Pump Sleeve Dome Stopper Dome Oversize O Ring Valve Stopper Spacer Ring Spacer O Ring sleeve Screw Ring Yacuum Tube Open End coi Tension System STEP 5 Once this is complete rotate the Vacurect so that the open end of the VACUUM TUBE is facing upward Slide the PUMP SLEEVE downward until it stops STEP 6 Holding the VACUUM TUBE and the PUMP SLEEVE in place unscrew the SLEEVE SCREW RING Apply two to three drops onto the O RING STEP 7 Repeat on the opposite side of sleeve O RING STEP 8 Replace the SLEEVE SCREW RING making sure that it is securely seated Do not over tighten STEP 9 After replacing the SLEEVE RING SCREW move the PUMP SLEEVE back and forth three to four times Your OTC CUSTOM is now ready for normal use IN DEPTH OILING AND ASSEMBLY INSTRUCTIONS In depth maintenance is required every four to six months Disassembly is straightforward thus this paragraph will depict oiling and assembly of the OTC CUSTOM components STEP 1 Verify all components are available for assembly The components include vacuum cylinder pump sleeve dome stopper valve m i stopper sleeve screw ring spacer and O rings a C O STEP 2 Place the valve stopper piece with ears on the peg located on the back of the vacuum cylinder as shown STEP 3 Place the dome stopper on the groove ridge as shown STEP 4 Ensure the dome
8. creation of the erection NOTE If your OTC CUSTOM requires a more intensive cleaning rinse it out with warm water and a mild soap DO NOT use a cleanser with harsh detergents e g dish soap as this will remove the silicone lubricant from the internal rubber seals STEP 3 Using a clean dry and soft cloth completely dry the inside and outside of the Vacurect STEP 4 Store the Vacurect system in your travel bag CLEANING INSTRUCTIONS OTC CUSTOM TENSION SYSTEM STEP 1 Rinse the Tension System with hot water to remove any lubricant STEP 2 Towel dry the Tension System completely and store in your travel bag OILING INSTRUCTIONS The OTC CUSTOM is pre lubricated and should not require any maintenance or service for four to six months DO NOT disassemble the Vacurect for oiling STEP 1 Hold the system with open end facing down slide the PUMP SLEEVE down towards the opened end of the VACUUM TUBE until it Stops STEP 2 Tilt the OTC CUSTOM to a 45 degree angle and apply two to three drops of the silicone oil onto the rib or vanes of the VACUUM TUBE located nearest to the DOME STOPPER The oil will move down the rib or vane to the O RING STEP 3 Rotate the unit 180 degrees and apply approximately two to three drops of the silicone oil onto the rib or vanes directly opposite side of the DOME STOPPER STEP 4 Move the PUMP SLEEVE up and down while turning it back and forth This
9. er After creating the erection the user removes the cylinder by releasing the vacuum pressure by pressing down on the tension system This action breaks the vacuum that releases the pressure and allows the user to remove the pump The tension system is left in place at the base of the penis capturing the blood in the penis and maintaining the erection After use the tension system is removed allowing the blood to circulate During and after removal of the tension system the penis returns to the non erect or flaccid state PRECAUTIONS If you suffer from any of the following conditions you should consult your physician before use e Curvature or pain associated with the erection Peyronies Disease e Prolonged erections Priapism e Sickle Cell Anemia e Decreased sensation or pain in the area of the penis e Abnormal blood clotting NOTE Although rare the most common irritation cause by a VED is minor discomfort and or bruising of the penis or scrotum These normally disappear within a few days The VED is designed to not exceed the safe limitations proposed by the Federal Drug Administration If any complications occur during use immediately discontinue use and consult your physician DOS AND DON TS e DO NOT Over Pump Take Your Time e DO NOT Use When Under The Influence Of Alcohol or Drugs e DO NOT leave the tension systems on for longer than 30 minutes at one time e DO NOT fall asleep with the tension system on e
10. here is no personal lubricant KY Jelly between the lip of the cylinder and the tension system or the tension system may not stay on the lip of the cylinder Tip 3 When pumping the system it is advisable to pump 2 or 3 times and pause for 10 to 15 seconds Continue to repeat this process and you will create a firm erection without feeling excessive pressure building inside the cylinder or the penis Tip 4 When you begin pumping the system let the penis draw through the tension ring DO NOT push the base of the cylinder toward the base of the penis Allow the vacuum to draw the penis entirely through the tension system and into the cylinder INSTRUCTIONS FOR USE Practice amp Sexual Activity Creating an effective erection with the Vacurect is as simple as steps through 5 STEP 1 Attach the tension system onto the cylinder by means of a light squeeze STEP 2 Apply a small amount of personal lubricant to the opening of the tension system STEP 3 Rest the tip of the penis in the opening of the tension system STEP 4 Move the sleeve up and down allowing the penis to be drawn through the tension system into the cylinder NOTE Once the cylinder is removed and the tension system is in place AND a more rigid erection is desired simply push the tension system back into the body If a more rigid erection is still desired pumping may resume without removing the tension system from the penis by placing the cylinde
11. r back onto the tension system and pumping once or twice pause and then remove the cylinder STEP 5 After creating the erection release the pressure in the cylinder from the tension system by touching the edge of the tension system with gentle pressure using one finger WARNING DO NOT leave the tension system on for longer than 30 to 45 minutes Once the tension system is removed allow 60 minutes between use of the tension system STEP 6 When removing the tension system first grasp the sides of the tension system with your thumb and forefinger and fold the tension system forward toward the head of the penis As you pull it forward the funnel opening will turn inside out Next squeeze the shaft of the penis for approximately 5 seconds This forces the blood back into the body Once the tension system is inverted you may want to apply a small amount of lubricant to the shaft and glans head of the penis and slowly slide the tension system off the penis CLEANING INSTRUCTIONS OTC CUSTOM DO NOT submerge the cylinder into hot water as this will remove the silicone oil from the O rings required for proper performance STEP 1 Clean the outside of the cylinder by wiping off any excess lubricant and or oil using a soft cloth and hot water STEP 2 Thoroughly wipe the inside of the Vacurect unit with a bottle brush or a soft cloth dampened with hot water The use of hot water helps dissipate any lubricant residue during the
12. rm the penis prior to sexual intercourse and or you can use K Y Warming Lubricants To decrease this Sensation make sure the tension system is placed as far back on the penis as possible Usually a decrease of penile temperature of one 1 degree occurs In some females the vagina is so sensitive they may feel this decrease most do not This is not a crucial factor to satisfactory intercourse HealthConnection Inc 1 800 838 8367 www AnActiveLife com 11