1. Pylon 1 A2 Pylon 1 A3 Pylon 1 A4 Displays 2 Blank DIESEL 95E 98E All Set Blank DIESEL 95E 98E All Set Blank DIESEL 95E 98E All Set Blank DIESEL 95E 98E All Set Pylon 1 B1 Pylon 1 B2 Pylon 1 B3 Pylon 1 B4 Blank DIESEL 95E 98E All Set Blank DIESEL 95E 98E All Set Blank DIESEL 95E 98E All Set Blank DIESEL 95E 98E All Set Directions are separated from each other by calling first direction as A and second as B Return to the main menu by pressing two times Shift F1 3 Set the prices Go to the menu prices DIESEL by pressing two times Enter in the main menu Now set the price for Diesel 1 012 by pressing the numbers in the keypad and press Enter Check that Save is selected and press Enter again You should be returned to the prices menu Repeat this procedure for the other fuel types 95E and 98E These should be visible in the prices menu If not ensure that first step was made correctly 1 Set the fuel types Views in the display should be as follows while setting the prices Prices DIESEL DIESEL Prices 95E DIESEL 95E 98E Save Cancel DIESEL 95E 98E Save Cancel Prices 98E Prices DIESEL 95E 98E Save Cancel DIESEL 95E 98E PIKOTEC OY 269 085 Tampere Tykkitie 1 FIN
2. menu gt settings gt dot pos ceceesceceeseeceececeeeeeceeeeeseteeeenteeeesaes 11 Usage Example ie e encased Ee aee a E E ce mnaeetenaaeoaaes 12 I Setth fuel types qualities rseissssri DEED 12 Die Set the pylon seiirt i a Ea aE EEEa E EEE RE EEEE HN 13 J SUK hi ts antes eerie 13 Z2 Transmit informati n t the pylon siessenek issii eb s Kad uo iei phia 14 RIMES SA DOS T a 14 Eon Nothing to E curi P 14 Error Pylon TN meee errr 14 Error N CUAL SC TH 14 Errore X Allready IST IIE laa ee abiecit Less uf odisea P UU e Serer ere ne 14 2 PIKOTEC OY Tel 358 3 3596000 Trade Reg No 269 085 Tampere Tykkitie 1 Fax 358 3 3596040 VAT number FI02982183 FIN 36240 Kangasala E mail pikotec pikotec fi ALV REK KOTEC RF Remote Control User Manual General Description RF Remote control is designed for sending pricing information into the fuel displays using wireless connection There could be several fuel displays in several display pylons Pricing information is entered to the remote control and it will send all the information simultaneously to the pylons So users don t have to send the pricing information individually to every pylon Features RF operational frequency is 433MHz Battery operated 3 x AA Up to1000m range in free space Range is usually less since it is reduced by trees buildings and o
3. Main menu AN PN Qualities Prices Dot Position not implemented in Pylons the pylon yet zl A Add Remove SW New ver Z gt ew 6 PIKOTEC OY Tel 4358 3 3596000 Trade Reg No 269 085 Tampere Tykkitie 1 Fax 4358 3 3596040 VAT number FI02982183 FIN 36240 Kangasala E mail pikotec pikotec fi ALV REK KOTEC RF Remote Control User Manual Menu Usage Main rules for navigation are e Press Enter to proceed to the selected menu bar downward in the menu structure e Press Shift F1 simultaneously to go back upward in the menu structure e Press Shift simultaneously to move up keep shift down and press T e Press Shift J simultaneously to move down keep shift down and press 4 Main menu Menu e Use arrow buttons Shift T or Shift b to move up or down Prices e Press Enter to proceed Settings e Transmit will transmit all pricing information from the remote control to the Transmit display or displays in the pylon or pylons Always remember to press the transmit button after changes If the pylon is not powered remote control will give an error message Likewise in other problems with transmission Prices menu menu prices Prices e Use arrow buttons Shift or Shift 4 to move up or down DIESEL e Press Enter to change the price of selected fuel 95E e Press Shift F1 to get back to the main menu TE e Note that prices could not be set befo
4. 36240 Kangasala Tel 358 3 3596000 Fax 358 3 3596040 E mail pikotec pikotec fi Trade Reg No VAT number FI02982183 ALV REK KOTEC RF Remote Control User Manual Return to the main menu by pressing Shift F1 4 Transmit information to the pylon Select Transmit in the main menu and press Enter Notice that this is example only If you don t have pylon where this information could be sent you get an error message If this pylon really exists you get message Success All prices sent Error messages Error Nothing to send This error occurs if you try to transmit but there is no any pylon set up in the remote control Use menu usage explanation Adding of New Pylon or Usage Example to set up pylon correctly pages 6 and 9 of this manual Error Pylon x x is a digit that denotes the particular pylon For some reason remote control could not send the information to the pylon Common reason is that there is no power connected to the pylon There are usually some digits visible in the pylons display if it is powered Other strong possibility is that distance between remote control and pylon is too great Go closer to pole with remote control and try to transmit again Error No qualitys defined This error occurs if you try to set up pylon or to navigate to the Prices menu before defining qualities fuel types Return to the main menu and define qualities as described in chapters Adding of n
5. L e This is the quality of second 2 display from the ground 95B e Use arrow buttons Shift T or Shift J to move up or down 98E e Press Enter to proceed All Set e Choose now some of the qualities for second display and press Enter Now the following menu will appear Pylon 1 A3 e This is the quality of third 3 display from the ground Blank e Use arrow buttons Shift T or Shift to move up or down DIESEL e Press Enter to proceed 2 e Because in this example there are only two displays All Set should be 1 chosen and Enter should be pressed When this is done new pylon is created Remember to navigate back to the main menu and to press transmit in order to send this pricing information to the displays in the pylon Removal of pylon menu gt settings gt pylons gt remove Rem Pylon e Use arrow buttons Shift 1 or Shift 4 to move up or down Pylon 1 e Press Enter to remove selected pylon Pylon 2 e Press Shift FI to get back to the pylons menu Pylon 3 Pylon 2 e If for example pylon 2 is selected this menu appears Remove e Use arrow buttons Shift T or Shift J to move up or down Cancel e Press Enter to proceed e Remove will remove the selected pylon Pylon 2 in this case e Cancel will return to remove menu without deleting selected pylon Editing of existing pylon menu gt settings gt pylons gt edit e Use arrow buttons Shift T or Shift J to move up or do
6. PIKOTEC RF Remote Control User Manual Rev A Jukka Viinam ki 19 08 2010 KOTEC RF Remote Control User Manual Table of Contents General Description PC S 3 Features T E E 3 Battery Tea ea NE P PE tassa keen 4 Using of RP Remote One T H 3 Meny Str ct fe PL 6 Ei r c 7 M MENU MC G 7 POSS menu menu Dp siosio eie libertades itid e dba uoto n mns tata EES 7 Settings menu ment SeP BS oe ecrvs soassa vo terr aon o NS Oct E Rec re PLUS VIS Sarain RUNE 8 Pylons menu menu gt settings gt pylons a uice iii beer in Iota tete BiRe sus estes aD e iu pA CE VO kera 8 Adding of new pylon menu gt settings gt pylons gt Add new eee 8 Removal of pylon menu gt settings gt pylons gt remove seen 9 Editing of existing pylon menu gt settings gt pylons gt edit eese 9 Qualitys menu menu gt settings gt qualitys eee eeseceenteceeeeceeaeeceeneeceeeeeceeeeeceeeeetteeeenaeees 10 Adding of new fuel type menu gt settings gt qualitys gt add new sess 10 Removal of fuel type menu gt settings gt qualitys gt remove sese 10 Changing the name of fuel type menu gt settings gt qualitys gt edit sssse 10 Changing the dot position
7. ew fuel type and Usage example pages 7 and 9 After that you should be able to set up new pylons and to set the prices without receiving this error message Error X Allready defined This error occurs if you try to add new fuel type quality but there is already fuel type with same name X in this case Use different name for your new fuel type for example Diesel2 Note that if you want just to change the price of this existing quality it could be done as described in chapter Prices menu page 5 14 PIKOTEC OY Tel 4358 3 3596000 Trade Reg No 269 085 Tampere Tykkitie 1 Fax 4358 3 3596040 VAT number FI02982183 FIN 36240 Kangasala E mail pikotec pikotec fi ALV REK
8. g SW ver the device will ask the software version from the pylon Pylon will answer by sending the software version and it will be shown in the display of remote control Pylons Add new Remove Edit Test SW ver Adding of new pylon menu gt settings gt pylons gt Add new Pylon 1 e Set the number of display sides directions by pressing numbers in the keypad Note that there could be only one two or three sides so only those Displays 1 are applicable values 1 3 e Press Enter to approve the amount of sides e Press Shift F1 to get back to the pylons menu without saving the changes Pylon 1 Al iE e This is the quality of lowest 1 display in the pylon DIESEL e Use arrow buttons Shift T or Shift 4 to move up or down 95E e Press Enter to proceed 98E e Press Shift FI to get back to the pylons menu without saving the changes All Set e Blank will set the lowest display empty All LEDs in that display are off e All Set will return to pylon menu after saving the changes e Example There are two displays in one side of the pylon Choose now some of the qualities and press Enter The following menu will appear 8 PIKOTEC OY Tel 358 3 3596000 Trade Reg No 269 085 Tampere Tykkitie 1 Fax 358 3 3596040 VAT number FI02982183 FIN 36240 Kangasala E mail pikotec pikotec fi ALV REK ei KOTEC RF Remote Control User Manual Pylon 1 A2 Blank DIESE
9. ift J to move up or down Press Enter to proceed Remove will remove the fuel type DIESEL in this case e Cancel will return to remove menu without deleting selected fuel type Changing the name of fuel type menu gt settings gt qualitys gt edit Edit quality e Move cursor to left and right by pressing arrow buttons Shift lt and DIESEL Shift 95E e Explore numbers and characters by pressing arrow buttons up and down 98E Shift T or Shift J e Press Enter to save changes e Press Shift F1 to get back to the qualitys menu without saving the changes e This menu could also be used to check out what fuel types there are in the memory of remote control 10 PIKOTEC OY Tel 358 3 3596000 Trade Reg No 269 085 Tampere Tykkitie 1 Fax 4358 3 3596040 VAT number FI02982183 FIN 36240 Kangasala E mail pikotec pikotec fi ALV REK KOT C RF Remote Control User Manual Changing the dot position menu gt settings gt dot pos e This function is not implemented in the display yet It is for the future development 11 PIKOTEC OY Tel 4358 3 3596000 Trade Reg No 269 085 Tampere Tykkitie 1 Fax 4358 3 3596040 VAT number FI02982183 FIN 36240 Kangasala E mail pikotec pikotec fi ALV REK D KOTEC RF Remote Control User Manual Usage Example In this example there is a fuel display pylon with six displays There are three displays on top of each other in two
10. nce this device is battery operated Check out the Battery installation in previous chapter This remote control could be used to control different kinds of fuel display pylons User could freely define the amount of displays per pylon amount of display sides directions and the location of fuel types in the pylon These settings have to be done only in the first time of use Remote control remembers the settings because they are stored to the non volatile memory Settings will remain even if the batteries are removed All the information could later be edited If user wants to change the fuel price this could be done simply editing the pricing information in the menu of remote control After transmit is selected all pricing information is updated to the displays of pylons simultaneously In this point user don t have to know how many and what kinds of pylons there are but just the new price of fuel Main steps when setting prices at first time e Set the fuel types Diesel 95E etc e Set the pylons including information about the number of displays and which side of the pylon they are situated e Set the prices e Transmit Main steps when changing prices later on e Edit prices e Transmit 5 PIKOTEC OY Tel 358 3 3596000 Trade Reg No 269 085 Tampere Tykkitie 1 Fax 358 3 3596040 VAT number FI02982183 FIN 36240 Kangasala E mail pikotec amp pikotec fi ALV REK KOTEC RF Remote Control User Manual Menu Structure
11. re qualities for example DIESEL DIESEL e Set the price by pressing numbers in the keypad e Move cursor to the left or right by pressing Shift lt or Shift gt 0 000 e Press Enter to approve the price e Press Shift F1 to get back to the prices menu DIESEL e Use arrow buttons Shift T or Shift to move up or down Save e Press Enter to either save the changes or to cancel Cancel e Press Shift F1 two times to get back to the main menu 7 PIKOTEC OY Tel 358 3 3596000 Trade Reg No 269 085 Tampere Tykkitie 1 Fax 4358 3 3596040 VAT number FI02982183 FIN 36240 Kangasala E mail pikotec pikotec fi ALV REK KOTEC RF Remote Control User Manual Settings menu menu gt settings Settings e Use arrow buttons Shift T or Shift J to move up or down Pylons e Press Enter to proceed Oualitys e Press Shift F1 to get back to the main menu Dot Pos e Dot Position is not in use yet so this should be ignored Dot is always after first digit for example 1 234 Pylons menu menu gt settings gt pylons Use arrow buttons Shift T or Shift J to move up or down Press Enter to proceed Press Shift F1 to get back to the settings By selecting Test the device will begin the testing sequence which will go through all the segments in the display This could be used to verify that all LEDs in the display and the RF link are operating e By selectin
12. sides See the picture beneath Picture 3 Example Pylon There are three types of fuel for sale 98E 95E and Diesel Prices are 1 762 1 327 and 1 012 respectively The prices are shown into two directions as shown in the picture 1 Set the fuel types qualities Go to the menu gt settings gt gualitys gt add new by using Shift 1 Shift J and Enter as described in the earlier chapter Now write DIESEL and press Enter You should be returned to the qualitys menu Press Enter write 95E and press Enter again Do the same thing with 98E Return to the main menu by pressing two times Shift F1 12 PIKOTEC OY Tel 4358 3 3596000 Trade Reg No 269 085 Tampere Tykkitie 1 Fax 4358 3 3596040 VAT number FI02982183 FIN 36240 Kangasala E mail pikotec pikotec fi ALV REK PIKOTEC 2 Set the pylon Go to the menu gt settings gt pylons gt Add new by using Shift T Shift J and Enter as described in the earlier chapter Press number 2 to impress that the displays reside in two sides of the pylon Now do the following selections Select DIESEL and press Enter gt Select 95E and press Enter gt Select 98E and press Enter gt Select All Set and press Enter Repeat this sequence Select DIESEL and Return to the main menu by pressing two times Shift F1 Views in the display should be as follows selections are bolded RF Remote Control User Manual Pylon 1 Pylon 1 A1
13. ther objects Radio conforms with EU R amp TTE directive EN 300 220 EN 301 489 EN 60950 Operational temperature range 30 C 70 C Amount of controllable devices by one remote up to o 9 Pylons with o 9 Displays with o 3 Sides 3 PIKOTEC OY Tel 358 3 3596000 Trade Reg No 269 085 Tampere Tykkitie 1 Fax 358 3 3596040 VAT number FI02982183 FIN 36240 Kangasala E mail pikotec amp pikotec fi ALV REK KOTEC RF Remote Control User Manual Battery Installation Remote Control operates with three AA batteries They are situated backside under the plastic cover When batteries are getting uncharged the display might go dim or it might glitter That is fixed by replacing all three batteries by fully charged Battery cover could be removed by unscrewing two screws as shown in the following pictures N N Picture 1 Unscrewing the cover Picture 2 Proper order of the batteries 4 PIKOTEC OY Tel 4358 3 3596000 Trade Reg No 269 085 Tampere Tykkitie 1 Fax 4358 3 3596040 VAT number FI02982183 FIN 36240 Kangasala E mail pikotec pikotec fi ALV REK KOTEC RF Remote Control User Manual Using of RF Remote Control Remote Control is controlled by keypad and the actions are shown in the display There is no separate power switch in the device Power is turned on if any of the keypad buttons are pressed and the power is turned off after 60 seconds if no key is pressed There is no need for separate power supply si
14. wn e Press Enter to edit selected pylon e Press Shift F1 to get back to the pylons menu e After pressing of enter the procedure is similar to adding new pylon 9 PIKOTEC OY Tel 4358 3 3596000 Trade Reg No 269 085 Tampere Tykkitie 1 Fax 4358 3 3596040 VAT number FI02982183 FIN 36240 Kangasala E mail pikotec pikotec fi ALV REK Bi KOTEC RF Remote Control User Manual Qualitys menu menu gt settings gt qualitys Qualitys e Use arrow buttons Shift T or Shift J to move up or down Add new e Press Enter to proceed e Press Shift F1 to get back to the settings menu Adding of new fuel type menu gt settings gt qualitys gt add new New quality e Move cursor to left and right by keeping shift depressed and pressing arrow buttons Shift lt and Shift e Explore numbers and characters by keeping shift depressed and pressing arrow buttons up and down Shift T or Shift 4 e Press Enter to save new fuel type guality e Press Shift F1 to get back to the qualitys menu without saving the changes Removal of fuel type menu gt settings gt gualitys gt remove Rem guality DIESEL DIESEL Remove Cancel Use arrow buttons Shift T or Shift 4 to move up or down Press Enter to remove selected fuel type guality Press Shift F1 to get back to the gualitys menu Menu looks like this if DIESEL is selected Use arrow buttons Shift T or Sh

Download Pdf Manuals

image

Related Search

Related Contents

Designjet 650  7 Inch IR Variable Speed Dome Camera  Samsung WD0704CQQ/XSP User Manual  Honeywell T834C2267 User's Manual  ForceMaster(1000MK HD) 取扱説明書 - Shimano  STUFA AGNESE, EMMA, LUCREZIA  Emergência e Negociação de Imagens das línguas em  Click Car Mouse VW Beetle Ultima Edicion  Hg2O User Manual - Amazon Web Services    