1. 7 TROUBLE SHOOTING To call for service please have the model serial number and description of the problem available PROBLEM POSSIBLE CAUSE SOLUTION NO LIGHT UPS 1 The power switch isin 1 Press power switch to turn on NOT ON OFF or not pressed 2 The voltage for battery is 2 Re charge the UPS at least 8 weak hours 3 Battery failure 3 Replace with the same type of battery or call for service 4 Power Connection looses 4 Check the input power and replug it again BUZZER BEEPS 1 Overload of the UPS 1 Remove the noncritical load or CONTINUOUSLY call for service BACKUP TIME IS Replace with same type of battery or call for service Battery failure SHORT OR 2 AC fuse may be burnout 2 Replace fuse or call for service ALWAYS IN 3 Battery is not fully 3 Re charge the UPS at least 8 BATTERY MODE _ charged hours POWER WALKER VI 400 600 800 Uninterruptible Power Supply USER S MANUAL 4 Power Connection loses A Check the input power and replug it again 11 PowerWalker Thank you for purchasing PowerWalker UPS Safety information and operating instructions are included in this manual To ensure the correct use of the UPS please read this manual thoroughly before operate it And save this manual properly 1 INTRODUCTION PowerWalker VI series is a line interacti
2. d relative humidity of 0 90 without condensing And place the UPS in a location free from excessive dust and chemical fumes Please notice that the UPS voltage and power rating match to the line voltage and load requirements 3 Connection Connect the power cord to the utility power to power up the UPS Press ON button to turn on the UPS the green light indicator illuminates that AC utility voltage 4 Charge is present the Battery Charge the battery automatically when UPS is connected to utility power Some charges may be lost It is recommended that the battery will be re charged for at least 8 hours before using the UPS 5 Connect the Computer Connect the interface cable from your computer to the output receptacles on the back panel of the UPS 6 Connect the Telephone Modem Line Connect a single telephone cable into the IN telephone modem surge suppression port on the back of the UPS Require another length of telephone cable to connect into OUT telephone modem port on the back of UPS to the modem input socket 7 Connect the RS 232 Port Connect a RS 232 serial cable from RS 232 on the back of the UPS to Computer Systems that will be auto detected 8 Green Mode Function Green mode enables to save the power if none of the load is connecting 9 DC Start Function When the power is not supplied from AC utility DC start function will be started up automatically 10 Switch Off Press OFF button to turn o
3. ff the UPS after use or test 5 MONITORING SOFTWARE 6 TECHNICAL SPEICIFICATION After the UPS has been installed you must install the software Smart Power that came packaged with your UPS Smart Power monitoring software performs the monitoring and controlling functions This software displays the status and diagnostic symptoms on the monitor In case of the power failure it provides the auto shutdown for the computer If you download the software from Internet please key the serial number 726T25 4791 2N39546 lowe ODEL PowerWalker PowerWalker PowerWalker VI 400 VI 600 vi 800 CAPACITY VA W 400VA 240W 6O00VA 360W 800VA 480W Voltage 110 120VAC or 220 230 240VAC INPUT Voltage Range 85 140VAC or 162 290VAC Frequency 45 65 Hz Auto Sensing Voltage Batt Mode 110 120 220 230 240VAC 10 OUTPUT eae Eat Mode 50Hz or 60Hz 1 Hz utput Waveform a line mode Battery mode Modified Sinewave Stepwave Battery Type 12V4 5Ah x 1 12V7Ah x 1 12V9Ah x 1 Backup Time at a PC BATTERY load with 15 monitor 8 minutes 20 minutes 30 minutes Recharge Time 8 hours to 90 after complete discharge ie tek Typical 4 6 ms and 13ms max AC Mode Green lighting INDICATOR Backup Mode Green flashing Backup Mode Sounding every 10 seconds AUDIBLE L Ba
4. green light indicator flashes when the internal battery is being used Back Panel IEC 1 Battery Power Supplied Receptacle The power supplied receptacles are used for battery to power up your equipments while AC is failure 2 AC Input Power Receptacle The power receptacle is used to plug in the power cord that provides power to the UPS 3 Circuit Breaker The circuit breaker is used to protect your equipment against the event of short circuit or system overload 4 Telephone Fax Modem Surge Suppression Port This surge suppression port is used to protect the telephone or modem line while connecting the 5 RS 232 Communication Port This communication port is used to communicate with a computer or modem and support the operating systems 4 INSTALLATION Before the installation please ensure the power switch on the UPS is in OFF position and the voltage of the AC utility source corresponds to the identification label on the rear panel 1 Inspect ion Inspect the UPS upon the receipt If there is any damage please report it to dealer immediately The packaging is used recyclable material please save it for reuse or dispose of it properly 2 Placement Install the UPS in a protected area within a temperature range from 0 40 C an
5. n the manual strictly To reduce the risk of electric shock the user must disconnect the UPS from the mains supply before installing any cable To reduce the risk of electric shock Do not attempt to disassemble the UPS This UPS is no user serviceable parts inside Please contact qualified service personnel to do any service Do not connect with laser printers cosmetic appliances medical equipments microwave ovens vacuum cleaners or heavy duty hardware to UPS because they take too much power Do not dispose of batteries in a fire They may explore Do not open or mutilate batteries They contain an electrolyte that is toxic and harmful to the skin and eyes Do not allow liquid or foreign object to enter inside of UPS Do not block off ventilation openings in the UPS system s housing Do not place the UPS near water or in environments of excessive humidity Remove personal metal items such as rings bracelets necklaces and watches when working with batteries Batteries can produce a short circuit current high enough to make metal melt and could cause severe burns 3 OVERVIEW Front Panel ORS FowerWalker J N 1 ON OFF Button Press the On Off button to turn on or off 2 LED INDICATOR On Line Indicator The green light indicator illuminates when the input line voltage is normal Backup Indicator The
6. tt Soundi d ALARM ow Battery ounding every secon Overload Sounding every 0 5 second PROTECTION Full Protection Discharge overcharge and overload protection PHYSICAL Dimension DxWxH mm 287x212x107 ENVIRONMENT Noise Level Less than 40dB Windows family Sun Solaris IBM Aix Compaq INTERFACE Smart RS 232 True64 UnixWare FreeBSD HP UX Linux and MAC 10
7. ve UPS which is designed to protect your personal computer or sensitive electronic equipments The UPS is equipped with boost to stabilize input voltage And it also employs microprocessor control and allows wide input voltage from 85VAC to 284VAC with overload protection The UPS can be automatically started up without AC power supplied In addition this UPS provides advanced modem or telephone line surge protection and compact design conserves space which can be placed in horizontally or vertically on your desk It is equipped with many features that allow any attached equipment to operate longer and more reliability It is ideal protection equipment against spikes surges sags or blackouts Description of Features Compact size and light weight design which can placed in horizontally or vertically on the cabinet or desk Easy to use and install Utilized microprocessor control to maximize the reliability and efficiency Equipped with built in boost function Cold start function Battery power energy saving and overload protection Provides advanced telephone fax or modem surge suppression protection Built in RS 232 with connecting intelligent monitoring software 2 SAFETY REQUIREMENTS Please save this manual properly This manual includes important safety information Please read it carefully and thoroughly before operating the UPS Comply with all the warnings and operating instructions on the unit and i