1. DIVISION 28 23 23 VAD7000 SERIES FIBER OPTIC TRANSMITTER AND RECEIVER ENGINEERING SPECIFICATIONS PART 1 GENERAL 1 01 SUMMARY A Fiber Optic FM Video Audio and Data Transceiver 1 02 SECTION INCLUDES A VAD7000 Series FM Video Audio and Data Transceiver Standalone B VAD7000 R3 Series FM Video Audio and Data Transceiver Rack Mount 1 03 REFERENCES A Underwriters Laboratory UL B Underwriters Laboratory Canada ULC C European Union Compliance CE 1 04 SYSTEM DESCRIPTION A Performance Requirements Provide a FM Video Audio and Data Transceiver system that transmits Bi directional Video Audio Data 1 The system shall utilize 850 nm optics capable of simultaneous bi directional video audio and data transmission on one single mode optical fiber VAD7010 A 2 The system shall utilize 850 nm optics capable of simultaneous bi directional video audio and data transmission on one single mode optical fiber V AD7010 B 3 The system shall utilize integrated WDM optics operating at 850 1300nm capable of simultaneous bi directional video audio and data transmission on one single mode optical fiber VAD7010OWDM A 4 The system shall utilize integrated WDM optics operating at 1300 850nm capable of simultaneous bi directional video audio and data transmission on one single mode optical fiber VAD7010WDM B 1 05 SUBMITTALS A Product Data Manufacturer s printed product data sheet for
2. transmission shall utilize an integrated WDM for increased stability and reliability of system performance The module shall provide power carrier detect data transmit data receive audio transmit audio receive and video status indicating LED s for monitoring proper system Section Title operation The modules shall provide automatic re settable solid state current limiters and independent voltage regulators on each module to reduce the chance of a single point failure of the system The module shall be hot swappable in arack mount system to reduce complete system shut down during maintenance or repair The module shall have an MTBF of gt 100 000 hours and operate in an environment of 40 C to 74 C and relative humidity between 0 to 95 non condensing The module shall be UL and ULC listed and CE marked The circuit board shall be UL 94 flame rated and meet all PCI standards All PC boards shall be designated with part number PC board number and show appropriate revision number Housing shall be of all metal construction All LED indicators and both electrical and mechanical connections shall be identified with silk screened labels The module shall have a lifetime warranty to reduce system life cycle cost in an event of a module failure 2 04 VIDEO SPECIFICATIONS Input Video 1 volt pk pk 75 ohms Bandwidth 5 Hz 6 5 Mhz Differential Gain lt 5 Differential Phase lt 5 Tilt lt 1 Signal Nois
3. and video monitor or other equipment used in the system 3 The carrier detect indicator LED should be lit confirming a presence of a carrier signal 4 Successful video link operation should be visible at this point as witnessed by a good quality video picture on the monitor B Testing the Fiber Optic Audio Link 1 Verify that the audio leads and optical fibers are properly connected 2 Make sure that power is applied to all fiber optic modules Pre amplifiers amplifiers or other equipment used in the system 3 Successful audio link operation should be confirmed at this point C Testing the Fiber Optic Data Link 4 Verify that the data leads and optical fibers are properly connected 5 Make sure that power is applied to all fiber optic modules controllers and receiver drivers or other equipment used in the system 6 Successful data link operation should be confirmed at this point by using the controller to pan tilt and zoom the camera or communicate with other equipment 3 05 CLEANING A Follow all instructions for proper use of solvents and adhesives used for termination and splicing B At completion of the installation dispose of all fiber scraps properly Section Title MANUFACTURED UNITS REFERENCE TABLES Table A Product Number Descriptions VAD7000 SERIES DESCRIPTION MAX DISTANCE VAD7010 MM Video Audio Data 850 lt gt Video Audio 2 5 Miles 4KM Data 850 2 Fibers VAD7010 R3 MM Vid
4. each type of Transmitter Receiver specified B Detail Drawings Electrical and optical connect drawings Product mounting template C Manufacturer s Installation and Operating Manual Printed installation and operating information for each type of Transmitter Receiver specified D Test Reports Manufacturer s Printed Test Report via a Tektronics VM700A Video Test Generator verifying product performance meets or exceeds the specified product performance referenced in Part 2 E Warranty Manufacturer s Printed Warranty 1 06 DELIVERY STORAGE AND HANDLING A Deliver materials in unopened factory packaging with Manufacturer s bar coding to the job site Project name project number date Optional information e g owner A E 00000 1 B Inspect product upon delivery to assure that specified products have been received C Store in original packaging in a climate controlled environment Storage Temperature not to exceed 40 C to 85 C 1 07 PROJECT SITE CONDITIONS A Temperature Requirements Products shall operate in an environment with an ambient temperature range of 40 C to 74 C without the assistance of fan forced cooling B Humidity Requirements Products shall operate in an environment with relative humidity of 0 to 95 non condensing If product is installed in condensation conditions unit shall have conformal coating applied to the printed circuit board 1 08 WARRANTY A Standard Interna
5. in compliance with the IFS installation manual C Optical Fibers 1 Caution NEVER look into the end of an Project name project number date active optical fiber when using laser light output Eye damage can occur Wear eye protection when cleaving terminating and splicing fiber 2 The number and type multimode or single mode of optical fiber shall meet the requirements of the IFS model number in article 2 06 used in the installation 3 All optical fiber cables shall be properly installed and terminated with the mating optical connectors as submitted in article 2 08 A 4 The optical link shall be tested with either a power meter at a minimum or OTDR to Optional information e g owner A E 00000 3 ensure the link budget overall path loss plus an added 3dB of optical safety margin does not exceed the optical power budget as submitted in article 2 06 5 All optical connectors on cable shall be cleaned in compliance to optical connector manufactures specifications and covered with dust caps until connection to the fiber optic module 3 03 INSTALLATION A General Locate fiber optic modules as indicated on the approved detail drawings and install module in compliance with the IFS installation and operations manual 3 04 TESTING A Testing the Fiber Optic Video Link 1 Verify that the coax and optic fibers are properly connected 2 Make sure that power is applied to all fiber optic modules camera
6. ber I T E 6D16 C UL 94 flame rated PCB board 94VO D 2 13 ACCESSORIES Jaw Project name project number date Optional information e g owner A E A B Card Cage IFS Model Number R3 EIA 19 card cage shall be available to house and power rack mount modules Blank Panels IFS Model Number R3 BP shall be available to cover unused rack slots PART 3 EXECUTION 3 01 EXAMINATION A Inspect modules before installation B Modules shall be free of any cosmetic defects or damage C All optical connectors shall be covered with dust caps and remain on the module until installing cable connectors to module D Shipping box shall include the module power supply and operations manual 3 02 PREPARATION A Standalone Module Surface Mount 1 Shall be mounted on a properly prepared surface adequate for the size and weight of module The placement of the unit shall allow provision for cable installation and maintenance as indicated on the approved detail drawings and in compliance with the IFS mounting template and installation manual B Rack Mount Module 19 Rack 1 Shall be installed in the IFS Model Number R3 card cage Ensure the card cage is installed in a standard EIA 19 482 6 mm rack or wall standoff bracket adequate for the size and weight of the card cage The placement of the unit shall allow provision for cable installation and maintenance as indicated on the approved detail drawings and
7. e Ratio gt 60dB 05 DATA SPECIFICATIONS Data Interface EIA RS 232 RS 422 Data Encoding Unit shall be transparent to data encoding i e NRZ NRZI Manchester Bi phase C Data Rate DC 100 kbps NRZ D Operation Mode Simplex or Full Duplex 2 05 B AUDIO SPECIFICATIONS E Input Output 2 2 volts peak to peak F Bandwidth 20 Hz 20 kHz G Input Output Impedance 600Q H Total Harmonic Distortion lt 1 0 2 06 OPTICAL SPECIFICATIONS A IFS Model Number VAD7010 Optical Fiber 62 5 125 micron Multimode Number of Fibers Required 2 Optical Wavelength 850nm Optical Power Budget 14 dB Optical Attenuation No manual adjustments required B IFS Model Number VAD7010OWDM Optical Fiber 62 5 125 micron Multimode Number of Fibers Required 1 Optical Wavelength 850 1300nm Optical Power Budget 14 dB Optical Attenuation No manual adjustments required 2 07 STATUS INDICATORS A Power On Red Off Off B Carrier Detect Video Carrier Active Yellow No Video Carrier Off BPP TM MOOw gt A M ad Section Title 00000 2 C Data Transmit Data Transmit Green No Data Off D Data Receive Data Receive Yellow No Data Off E Audio Transmit Audio Transmit Green No Audio Off F Audio receive Audio Receive Yellow No Audio Off G Video In Video In Red No Video Off 2 08 CONNECTORS A Optical ST B Power Audio and Data Terminal Block with Screw Clamps C V
8. eo Audio Data 850 lt gt Video Audio 2 5 Miles 4KM Data 850 2 Fibers Rack Mount VAD7010WDM A MM Video Audio Data 850 lt gt Video Audio 2 5 Miles 4KM Data 1300 1 Fiber VAD7010OWDM A R3 MM Video Audio Data 850 lt gt Video Audio 2 5 Miles 4KM Data 1300 1 Fiber Rack Mount VAD7010WDM B MM Video Audio Data 1300 lt gt Video Audio 2 5 Miles 4KM Data 850 1 Fiber VAD7010OWDM B R3 MM Video Audio Data 1300 lt gt Video Audio 2 5 Miles 4KM Data 850 1 Fiber Rack Mount Maximum distance is limited to optical loss of the fiber and any additional loss by connectors splices and patch panels Table B Product Compatibility Chart TRANSCEIVER COMPATIBLE TRANSCEIVER VAD7010 VAD7010 VAD7010 R3 VAD7010 R3 VAD7010 VAD7010 R3 VAD7010OWDM A VAD7010WDM B VAD7010WDM B R3 VAD7010OWDM A R3 VAD7010WDM B VAD7010WDM B R3 VAD7010WDM B VAD7010OWDM A VAD7010OWDM A R3 VAD7010WDM B R3 VAD7010OWDM A VAD7010OWDM A R3 END OF SECTION Section Title 00000 4 Project name project number date Optional information e g owner A E
9. ideo BNC Gold Plated Center PIN 2 09 ELECTRICAL SPECIFICATIONS A Power 24 VAC CT B Current Protection Automatic re settable solid state current limiters C Voltage Regulation Solid state Independent on each board D Circuit Board UL 94 flame rated and meets all PCI standards E Rack mount Card Shall be hot swappable with IFS Model Number R3 EIA 19 card cage 2 10 MECHANICAL SPECIFICATIONS A Surface Mount Dimensions VAD7010 VAD7010WDM 7 x 4 9 x 2 0 17 8 cm x 12 5 cm x 5 1 cm B Rack Mount Dimensions VAD7010 VAD7010WDM 7 7 x 5 0 x 2 0 19 6 cm x 12 7 cm x 5 1 cm C Number of Rack Slots 2 D Finish Module shall be constructed of a metal enclosure with a powder coat finish model Number F63B12 with all connections and indicators silk screened directly on unit Rack mount units shall be constructed of anodized aluminum E Weight lt 2 0 Ibs 1 0kg 2 11 ENVIRONMENTAL SPECIFICATIONS MTBF gt 100 000 Hours Operating Temp 40 C to 74 C Storage Temp 40 C to 85 C Relative Humidity 0 to 95 non condensing If product is installed under condensation conditions unit shall have conformal coating applied to the printed circuit board Add C to model number for conformal coated printed circuit board 2 12 REGULATORY AGENCIES APPROVALS AND LISTINGS A Underwriters Laboratory UL Listing Number LT E 6D16 B Underwriters Laboratory Canada ULC Listing Num
10. tional Fiber Systems Comprehensive Lifetime Warranty IFS warrants the product to be free of factory defects under manufacture s Lifetime Warranty as submitted under article 1 05 E PART 2 PRODUCTS 2 01 MANUFACTURER A Acceptable Manufacturer International Fiber Systems Inc 16 Commerce Road Newtown CT 06470 USA Telephone 203 426 1180 Fax 203 426 3326 Email sales ifs com Internet www ifs com B Substitutions Not Permitted C All fiber optic modules shall be supplied from a single manufacturer 2 02 MANUFACTURED UNITS A Model Number Descriptions Reference Table A Product Number Descriptions B Model Compatibility Chart Reference Table B Product Compatibility Chart 2 03 GENERAL SPECIFICATIONS A The FM Video Audio and Data Transceiver system shall be an IFS VAD7000 series The module shall be capable of transmitting full color video in real time in NTSC PAL or SECAM formats The module shall support the transmission of simplex or duplex audio as well as RS 232 RS 422 data The module shall be transparent to data protocols used by various manufacturers providing for universal compatibility should future system expansion or changes be required The module shall require no in field electrical or optical adjustments or in line attenuators to ease installation The module shall transmit the video audio and data signals using frequency modulation of the optical signal The simultaneous video audio and data
Download Pdf Manuals
Related Search
Related Contents
Catálogo Nº3 - Diversas actividades deportivas, novedades y DOMIcompact C 24 - Repuestos Ferroli Alicante GE 85206HD Instructions / Assembly V7 CAT5e Cable RJ45 STP Shielded Blue 2 m AG Neovo Neovo X-215 User's Manual manuale TG180 Cables to Go DCBD50 User's Manual Universal Messgerät zur Mengen-, Druck-, Niveau 取扱説明書 ”A C,川E METER Press Release Press Release Copyright © All rights reserved.