1. ted by the main display The untared pressure value is always shown on the bar graph display Thus the Digital Gauge s actual working load can be read off even if the tare function is active When the tare function is active a function indicator w appears on the display There are two 1 Select the tare function and set the value to be tared using the keys GG When set the measured value to be tared is backed up as tare The main display and the auxiliary display then show the value 0000 in the unpressurised state Example If a value to be tared is set as 2 bar the main display indicates 0 bar in the unpressurised state 2 Load the Digital Gauge with the pressure to be tared The current measured value appears in the main display field of the main display Select the tare function and then operate both keys simultaneously Dam The current measured value will be backed up as tare The main display and the auxiliary display are set to 0000 Setting the tare value to 0000 resets the tare function in both models 3 Technical Data Series 1000 with 4 digit 7 segment Optional with 4 5 digit 7 14 segment second display Display 11mm high bar graph display Accuracy 0 25 Full Scale BFSL 1 digit 7 0 5 Terminal Point Update rate 5 sec Measuring ranges 0 psig to 30 psig through 0 psig to 10 000 psig others on to EN reguest Compound ranges from 30 30 psig through 30 600 psig Type of pressure Positive ove
2. F 10 60 Stainless steel Optional black protective cap 2 Conformity declaration on request 0 0 4 Conformity The Digital Gauge complies with all requirements of EN 613 26 with regard to interference emission and immunity for use in industrial areas NOSHOK recommends the use of shielded cables Installation and cable routing must be carried out correctly in order to maintain the effective protection from electromagnetic interference The Instrumentation Company CORPORATE HEADQUARTERS 1010 West Bagley Road Berea Ohio 44017 440 243 0888 FAX 440 243 3472 E MAIL noshok noshok com WEB www noshok com
3. USER MANUAL PRESSURE ce Digital Pressure Gauges y SERIES 1000 HIGH PERFORMANCE DIGITAL PRESSURE GAUGES 1 Description of Parameters Series 1000 Display Screen Max value Bar graph display Min value Full scale Main display Unit LO BAT Series 1000 Optional Display Screen M Bar graph display value Min value 2nd display Full scale Main display Unit LO BAT Special function Tare Function in normal mode Function Action switches the device on switches the device off changes to programming mode if pressed for longer than 3 secs Display indicated max value as long as key is pressed Display indicates min value as long as key is pressed Resets max value to pe Resets min value to 04 The min max memory is updated with the current measured value in every measuring cycle The min value is displayed by pressing the min key The max value is displayed by pressing the max key Pressing and holding the appropriate key min or max and guickly pressing the menu key at the same time resets the device to the current measured value Bar Graph with Trailing Pointer Function The integrated bar graph display with trailing pointer function addi tionally indicated on the display shows the trend in current working pressure regardless of the digital display With the help of the trailing pointer function the max stored va
4. ion MAX on Factory seting OFF PEHA MENU The password is generated changed using this function PH swore gt MIN w 0000 Min Key changes character of display on entry Max Key sets display value 0 9 on entry Factory setting 0000 3 v MPa Unit may be selected oh Factory setting BAR lt TARA PY LI MIN gt 0000 tversion without initiat pressure enter tare value using keys Version with initial pressure press both keys together le Entry is continuous without changing character y see Pkt 6 Programming Tara function Factory setting 0000 LIGH Background illumination may be selected MA In ON position illumination remains switched men MAX a on for 15 secs after every key operation gt for ter every key operati ROFF rene o MIN or Automatic switch off time of device may be selected 15 in minutes le mem 30 Factory setting OFF 2 120 FRE o van Resets at parametara seting Factory setting NO ram Maxa wore Ti MENU STOR L rites min stores alt parameter settings Factory setting NO MAXa no Ea O Normal Mode Optional Tare Function In this mode the positive deviation of the measured value from the tared value max 20 of the measuring range is constantly indica
5. lue is also indicated in the bar graph display in addition to the digital display in the form of a bar segment This bar segment is also updated to the current measured value when the min max value is reset 2 Programming Series 1000 Standard Programming Software version Display Measuring range Unit UNIT Storage of settings STORE Normal Mode y 1097 w 1 FS 2000 WC UU BAR MIN Ha Unit may be selected 551 Factory setting BAR MENU MIN YES Stores all parameter settings Shar Factory setting NO JON OF FI Normal Mode Software version Display Measuring range Password entry PASS Password status P STATUS Password change P CHANGE Unit UNIT Tare function TARA Background illumination LIGHT Automatic Switch off time A OFF Factory settings FACTORY Storage of settings STORE Normal Mode 53 sec Optional Programming Fs 0002 PSS 55 oT hun y Min 09 changes gure of cept on any Max Key sets display value 0 9 on entry setzt meno MAX a Factory setting 0000 MIN OFF Password is active in ON position PASS does not appear in menu in OFF posit
6. rpressure negative overpressure Overload limit Twofold max 15 000 psig Wetted Measuring ranges gt 750 psig stainless steel AL 203 NBR Materials Measuring cell ceramic Measuring ranges gt 1500 psig only stainless steel measuring cell thin film technology NPT other connectors on request Stability per year lt 0 2 0 9 under reference conditions MIN MAX not volatile even when changing batteries Programming mode Parameters Password Optional settable e Tare Optional lt 20 settable Automatic option 2 90 min factory set switch off time Optional settable e Measuring unit bar PSI MPa selectable Illumination of Optional display Voltage supply 2 1 5V cell AA Operating life 4000h AA 2000 mAh 1 Measuring deviation to IEC 61 298 2 including non linearity hysteresis deviation of zero point and upper range value 0 F to 140 F 0 60 comp range Temperature effect e Zero point lt 0 15 Measuring range lt 0 15 Degree of pro IP 65 to 605 29 5 29 tection permissible rel 90 non condensing humidity Emitted inter to EN 613 26 ference 2 Temperature ranges e Storage 4 F to 158 F 20 70 Mat measured 22 F to 185 F 22 F to 212 F for measuring range gt 1500 psig 30 85 C 30 100 C for measuring range 2 100 bar Environment 14 F to 140