Home

Infinity_v140_RelNot..

image

Contents

1. Opening two instances of the Administration tool can cause errors Opening two Administration tools and then closing the second one can cause the first tool to go into a state in which making changes and saving them causes errors It may take up to two minutes after resetting minimum temporary storage before DICOM services will start When permanent storage is full to Query Retrieve studies stored on Infinity use the AE title temp set up on the DICOM Store SCU e g workstation When performing an upgrade from 1 2 0 if the system name is not set or the system name is changed when performing the upgrade DICOM stations configured in the Study Manager will not be preserved Infinity cannot compress certain study types Infinity will not compress Enhanced CT or Enhanced MR studies using lossy compression when the system is configured to compress incoming studies Upgrading from 1 1 0 or 1 2 0 software to 1 4 0 software does not create JPEG images for studies already stored on the Infinity system Contact Codonics Technical Support to generate JPEG images for web viewing of studies already stored with 1 1 0 or 1 2 0 software Technical Support If problems occur during software installation contact Codonics Technical Support between the hours of 8 30AM and 5 30PM EST weekends and U S holidays excluded Phone 1 440 243 1198 Email support codonics com Website www codonics com A CODONICS We bring the
2. x 1Sa Layout Size SINX10IN Destination MAGAZINE v il EFN Orientation PORTRAIT Medium Type PAPER v il BW Background BLACK Border Density BLACK v nd Magnification NONE Smoothing rite Resolution N A Requested Image Size O mm oe sige DECIMATE Include Owner ID i e series Raf Margin mmm Printer resolution Right Left Rows 2048 5 Up Down Columns 2048 Configuration Information 2010 0150 7 1 Cancel Help Close 5 The Print confirmation screen will reappear Select OK gt O CODONICS A Silence Alarm button was added to the System Status user interface If the system is beeping a user can now mute the system using the mute icon on the System Status user interface This mechanism is in addition to the mute button on the front of the chassis Storage Network System UPS Drives Temperature Silence Alarm Product Improvements Improved configurator To support the new product features the configurator found on the SmartDrive has been improved A user can add feature keys and set up the SmartRouting feature in the configurator The instructions for set up are found in the Infinity Quick Reference Guide which comes with each Infinity System Locale Purge Temporary Studies Minimum Temporary Space TB SMTP Username SMTP Password Edit Secure SMTP Setting Updated RSS feedreader icon in the system tray To alert a user the RSS
3. feedreader will now pulse when there is anew event To stop the pulsing click on the icon and open up the feedreader A database backup is created each night Contact Codonics Technical support if there is a need to access the backup Do not reboot during this time See Known Common Issues Defects Corrected The Infinity Viewer may display incorrect slice location information As described in Infinity Product Bulletin 301 part number 903 300 001 incorrect slice location information may be displayed by the Infinity Study Manager and DICOM Viewer In the software 1 4 0 the viewer does not display the slice location information such as image plane orientation direction or distance with regards to the DICOM referential zero The Configurator did not detect problems with IP subnet or gateway addresses If a user enters an incorrect IP subnet or gateway address e 256 XXX XXX XXX in the Configurator there is now a warning to the user that it is incorrect Support for Internet Explorer 6 The System Status user interface is properly displayed using IE6 An upgrade install will now preserve DICOM stations configured in the Study Manager The DICOM stations will not need to be reentered into the Study Manager Known Common Issues This section details common issues with Infinity 1 4 0 software that are likely to be experienced by most users Rebooting the Infinity between 3 30 AM and 4 30 AM system clock during a d
4. retrieved with the other patient s images This situation could also occur if the Administration tool is incorrectly configured to use a Study Matching type that is not Study UID such as Accession Number or Study ID and the chosen identifier is not unique within the facility Infinity does not accept certain transfer syntaxes A transfer syntax of 1 2 840 10008 1 2 2 Explicit VR Big Endian cannot be stored to Infinity Infinity beeping and muting capability If there is an issue with the RAID card the system will beep The beep can only be muted after Infinity software has started Ifthe system was improperly shut down and the RAID card is in a failure or critical state the system will beep for two to three minutes during software start up Studies may be sent to the trash if the system is rebooted during study transfer It is possible that patient images will be placed in the trash if the system is rebooted during a study transfer Do not reboot or shut down Infinity until all images from a study are present in the Study Manager In the Infinity Configurator attempting to cut copy or paste text in the fields produces incorrect outputs A user should properly type in any letters or numbers and not use shortcuts to copy text gt O CODONICS A hard power loss could result in data corruption To prevent this condition connect Infinity to a Codonics recommended Uninterruptible Power Supply UPS and minimize t
5. Codonics Infinity 4 Release Notes Operating Software Version 1 4 0 Release Notes Summary Version 1 4 0 software provides new features product improvements and corrects defects for the Codonics Infinity C Medical Image Server The software is only compatible with Infinity C systems It is not compatible with Infinity LX systems The Infinity Medical Image Server is an expandable DICOM storage appliance that provides a solution for storing and retrieving medical images Applications include temporary storage of large DICOM data sets directly from any modality and storage of digital images in an environment without a centralized digital image archive New Features Support for Infinity Medical Image Expansion Modules EM Expansion is available in 3TB increments up to 9 TBs total A user can have one EM attached to an Infinity C 5 7 TBs usable storage two EMs 8 7 TBs usable storage or three EMs 11 7 TBs usable storage SmartRouting of studies from Infinity The SmartRouting feature provides users the capability to have studies stored to Infinity and automatically forwarded to up to five destinations Routing rules allow users to configure their Infinity to route specific studies series or images to specific destinations Or studies can be automatically routed to another DICOM storage device like Infinity to create a backup of their Infinity SmartRouting requires a feature key on the Infinity SmartDr
6. Columns 2048 Cancel Help You will be asked to test the printer Select OK A DxPrintSpooler i In order to get more information about the printer it is strongly recommended to test the printer The Spooler Setup will show the new printer added Select Test and then click OK when the DxPrintSpooler box opens Select OK on the Spooler Setup page to complete the setup Spooler Setup Printer List Printer Name State Last Status amp DICOM_Printer Enabled NORMAL amp DICOM_Printer2 Enabled Unknown Edit Spooler Configuration Spooler Directory Spooler Control The spooler is running Disable Info Test FREER C opt Infinity Viewer Spool D xPrint H Stop Click Stop to halt the spooler gt gt O CODONICS Printing Instructions 1 After evaluating a study in Study Manager select File and Compose page 2 Study Manager File Edit View Tools Processing Window Open Chrl o Close i Ae HF Load recent File Chrl L Gea EA ape Select Browse Ctrl B New Clear selection Chri h Open CD work list Chri DICOM Console Dx Scanner Save 5 Chrl 4 Screen capture Print Ctrl P Print preview Print setup Page setup Compose page Switch User Lack Exit 2 The Template Page Layout will open Select the DICOM printer in the Printer field Then select the Add icon which will open the Add screen Select which fr
7. ames you want to print and then select OK amp Template 1x1 w Film Paper 8INX10IN v Add Frames all Displayed O Odd O Even Step Sth H ae a qm Printer amp DICOM_Printer Orientation PORTRAIT Reverse order oO Cancel Append Overwrite Insert vr Sal Whole series ALAR AAA UG 1 KN lt 4 gt D Close se gh 3 Click on the printer icon The Print confirmation screen will appear Select the Name of the printer to use amp Template 1x1 Film Paper SINX10IN Printer DICOM_PRINT_E v jE Orientation PORTRAIT Print DICOM printer Fill Name DICOM_PRINT_BOTH v ial verwrite State Enabled Insert Last status NORMAL p 2 a Print range Copies i Whole series All Number of copies 1 S Current li H W O Pages from 1 OK Cancel i A my IT MR Cerera Hospl 4 Select Properties which will open the Layout page for the job On this page a user can override the system default settings for a specific job by adjusting the settings for Size Medium Type and Printer resolution Select OK NOTE Infinity does not support true size printing NOTE To print unlisted media sizes e g A A4 14x36 14x51 consult the printer s user manual amp Template 1x1 Film Paper 8INX10IN Printer DICOM_PRINT_E Orientation PORTRAIT Mi
8. atabase backup will cause Infinity to stop working Do not reboot your system during this time Contact Codonics Tech Support if a reboot occurs and the system needs to be restarted Disconnecting the SAS cable or power cable to the EM during data transfer can lead to loss of data Refer to Infinity Medical Image EM User s Manual for further details The LEDs on the Infinity C hard drives are red until the Infinity software is running The LEDs on the front of each hard drive are red when the Infinity is turned on and stay red until the Infinity software is running Do not pull a drive during this time The Login dialog box is delayed for Remote Desktop Connection When a user first opens Remote Desktop Connection for Infinity there is at least a 30 second delay before the Login dialog box opens During this time a blank blue background is displayed This condition only occurs for the first time after a reboot Subsequent logins occur more quickly gt O CODONICS Automatic system shutdown will not occur if studies are opened for viewing in the Infinity Study Manager Audit logs are not fully enabled as a default setting Audit logging must be enabled from the Infinity Administration tool E mail status notifications might be handled incorrectly by different e mail clients Hotmail treats Infinity e mail as spam and requires that a user click Display the Message Yahoo Mail also treats Infinity e mail as spam and puts it i
9. future into focus 17991 Englewood Drive Codonics Limited KK Cleveland OH 44130 USA New Shibaura Bldg F1 440 243 1198 1 3 11 Shibaura 440 243 1334 Fax Minato ku Tokyo 105 0023 JAPAN Email info codonics com Phone 81 3 5730 2297 Copyright 2008 2010 Codonics Inc Printed in the U S A Patent Pending Part No 901 231 001 05 www codonics com Fax 81 3 5730 2295
10. he number of times Infinity is hard powered down If the SmartDrive is inserted or removed from the Infinity the tree on the left side of the System Status user interface will become out of sync with the panes on the right A user should either refresh the browser using CTRL F5 or close the System Status user interface and reopen it to correct the issue Deleting a study using the Infinity Study Manager when it is still receiving studies causes orphan files If a user deletes a study while it is still being received the remaining incoming files will still be processed but will not belong to any study e Reboot time may take longer when Infinity is in a critical state e g if the RAID array is rebuilding The time it takes for Infinity to reboot is longer when it is in a critical state than when it is in an optimal state e When Infinity is set to Japanese locale it may display question marks when hovering over Windows system time Manually setting the format to English and then back to Japanese refreshes Infinity and displays the appropriate kanji characters 1 Open the Start menu and click Control Panel 2 Click Regional and Language Options 3 Select English Format 4 Select Japanese Format Get it all with just one call 1 800 444 1198 All registered and unregistered trademarks are the property of their respective owners Specifications subject to change without notice 5 Click the Apply button
11. ive for activation which can be obtained by contacting your Codonics Sales representative DICOM print Users can now DICOM print from the Infinity Study Manager Printer Setup Instructions 1 2 After logging into Infinity from the desktop setup the Printer by selecting Start gt All Programs gt DICOM Print Setup lelnniin al i A Administration 43 My Computer a English Study Manager Run Japanese Study A yi ndows Securit Q Manager y Wi ity Cy System Status Remote Support D System Shutdown All Programs D m Startup gt DICOM Print Setup English yect amp DICOM Print Setup Japanese Enter User Name default ADMIN and Password default Codonics Connection to the Database Warming Not Intended for Primary Interpretation Please enter your name and password if you want to be connected to the database User ADMIN Database Database New Password Cancel gt O CODONICS 3 The Dx Print Spooler will open Select Spooler and Setup amp Dx Print Spooler Spooler Job Setup 9 PEEN Suspend Printer Journal 4 The Spooler Setup will open Select New Spooler Setup Printer List Last Status amp DICOM_Printer Enabled NORMAL Edit Disable Info PERLE Test Spooler Configuration Spooler Directory C optel nfinity Viewer S pool DxPrint E Spooler Control Stop Clic
12. k Stop to halt the spooler OK i The spooler is running 5 The Create new printer screen will open In the Printer Parameters tab enter the Printer User Name Client AE Title Printer AE Title Printer IP Address Printer Port Number and select either Enable Grayscale or Color Create new printer Printer Parameters Layout Identification Parameters UserName DICOM_Printer2 DICOM Parameters Client AE Title DxDCMclient Printer AE Title Printer_AE Port Number 104 Printer 101 907 Secure Connection Configuration File C opt Intinity Viewer ete de_print cfg Es Advanced Printer Parameters Resolution DPI 300 Allow Job Control T Enable Grayscale W Enable Color J Cancel Help 6 In the Layout tab a user can set their printer s default settings The Printer resolution i e printer s imageable area is dependent on the Size and Medium Type Select OK Create new printer Printer Parameters Background Margin mm Right Up Size 8INxX10IN Destination MAGAZINE Orientation PORTRAIT Medium Type PAPER Magnification NONE X Smoothing Resolution N A X Requested Image Size O mm Decimate DECIMATE v Include Owner ID D Crop Configuration Information 2010 0150 Layout BLACK X Border Density BLACK X Printer resolution Left Rows 2048 Down
13. n the spam folder A user has to go to the spam mailbox and click the e mail to indicate to Yahoo that it is not spam Automatic system shutdown will not occur if DICOM settings are not saved and the Infinity Administration tool remains open A user should save their settings and close the Administration tool before shutting down the system Refreshing the System Status user interface page navigates a user back to the main page When refreshing the System Status user interface e g by pressing the F5 key or using a browser button the main page always displays For example if the Drives page is currently displayed refreshing the page does not refresh the Drives page but instead displays the main page Selecting Search without any criteria may return too many studies in the Infinity Web Viewer A message will alert a user that there are too many studies Use a criteria in one of the searchable fields e g Smith in the Patient Name Field to reduce the number of studies returned Sorting on columns in the Browser tab of the Infinity Web Viewer may display a message that too many studies exist if the current search criteria returns too many studies Using the Infinity Web Viewer browser s Back button can cause the Login prompt to display It is recommended not using the Back button when using the Infinity Web Viewer When using the Infinity Web Viewer pressing the Enter key rather than clicking on the Search button when searchi
14. ng may cause the user to be logged out If a user makes changes to their user preference settings in the Infinity Web Viewer and then exits the browser without logging out the changes are not saved for future sessions Save preference settings before logging out When storing studies in the Japanese locale Latin 1 e g English names that include special characters e g umlauts will not display the special characters The Help About screen on the Infinity Web Viewer incorrectly states that the version is Beta 1 The locale setting in the Configurator utility on the SmartDrive will permanently set the database for a specific locale and cannot be changed Once Infinity is configured to a specific locale Japanese or English any changes to the locale setting will cause studies stored before the locale change to be unsearchable and display incorrectly Known Uncommon Issues This section details uncommon issues with Infinity 1 4 0 software that are unlikely to be experienced by most users When exporting studies from Infinity Storage Commit is not supported If the Storage Commit box is selected in the Export Tab of the Administration Tool the Infinity will retry the storage commit request but will ultimately not succeed WARNING Images for one patient could be included in a study for another patient If a patient s images have the same Study UID as another patient s images then images from one patient could be