Home
3600B Series Bench Scale - Avery Weigh
Contents
1. Display and Controls Place the scale on a solid surface and level the scale by using the level bubble located under the scale platform as a guide Loosen the jam nuts on the leveling feet and turn them until the bubble indicates level Tighten the jam nuts Figure 2 shows the control panel of the 3600B series bench scales This panel contains the weight display annunciators and keys WEIGH TRONIX Keys Annunciators Figure 2 Control panel ZERO Use this key to zero the scale Default zero window is 100 of capacity If weight falls outside the zero window the zero key will not work UNITS Use this key to change unit of measure to either Ib kg or g PRINT Use this key to send weight information to a peripheral de vice GROSS NET Use this key to switch the display between gross and net displays TARE Use this key to tare a weight from the scale Following are the annunciators which appear on the display LB KG G NET MOTION ZERO LO BAT Operating the Scale Powering Up the Scale Always plug the scale into an appropriate eas ily accessible outlet with an earth ground Failure to do so may Warning cause a fatal shock The scale requires a 120 VAC 60 Hz power source isolated from electrical noise inducing equipment such as motor starters fluorescent lighting etc The scale is supplied with a UL standard 3 prong plug for AC operation and must be connected to an outlet which provides a thir
2. 514 695 0380 Toll free 800 561 9461 Facsimile 514 695 6820 www weigh tronix ca
3. CR gt lt ETX gt Scale is zeroed returns scale status T lt CR gt lt LF gt hh lt CR gt lt ETX gt Scale is tared returns scale status U lt CR gt lt LF gt uu lt CR gt Unit of measure is changed lt LF gt hh lt CR gt lt ETX gt returns the current unit followed by the status lt LF gt lt CR gt lt ETX gt Unrecognized command 8 3600B Series Bench Scale User s Manual Weight Command W Scale Status Command S Zero Command Z High Resolution Command H Undefined Commands Serial Data Transmission Modem control lines are not supported for RS 232 This command causes the scale to return a WYSIWYG What You See Is What You Get of its display when it is in normal weighing mode That is the scale will send whatever is showing on its display including any minus sign and or decimal point If it is weight the units of measure will be returned in addition to the displayed weight For decimal weight the length of the weight field will be equal to the length of the scale s display plus two or three one for the decimal point if necessary and two for the units e g Ib Units of measure will appear in their ANSI standard abbreviated form Ib for pounds kg for kilograms etc If the scale is displaying all upper bars over capacity the weight field will be filled with carets 4 444 If the scale is displaying all lower bars under capacity the weight field
4. will be filled with underscores If the scale is displaying middle bars zeroing er ror the weight field will be filled with dashes ra There are three status bytes The status bits are defined as follows Bit First Status Byte Second Status Byte Third Status Byte 0 1 Scale in motion 1 Under capacity 1 Low battery 0 Stable O Not under capacity 0 Not low battery 1 1 Scale at zero 1 Over capacity Always 0 O Not at zero O Not over capacity 2 1 RAM error 1 ROM error 1 Net Weight O No RAM error 0 No ROM error 0 Gross Weight 3 Always 0 1 Faulty calibration data Always 0 0 Calibration data okay If zeroing criteria are met the scale is zeroed In any case scale status is returned It is the same as the W command except that when weight is returned it is returned with ten times the scale s displayed resolution Thus for decimal weight the length of the weight field is equal to the length of the scale s display plus three or four When the scale receives an unrecognized or unsupported command it returns a question mark Baud Rates 1200 2400 4800 9600 19 200 Word Length 10 bits 7 Data 1 Parity Parity Even Odd or None 3600B Series Bench Scale User s Manual 9 Optional 8213 Protocol Commands lt STX gt 0OXX XX lt CR gt Pounds See notes 1 2 lt STX gt 0OXX XX lt CR gt Kilos See notes 1 2 lt STX gt 0XX XX lt CR gt Ounces See notes 1 2 lt STX gt 00XXXX lt CR gt Ounces Se
5. Avery Weigh Tronix p 3600B Series Bench Scale User s Manual UNITED STATES This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CANADA This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class A prescrites dans le R glement sur le brouillage radio lectrique que edict par le minist re de2s Communications du Canada EUROPEAN COUNTRIES WARNING This is a Class A product In a domestic environment this product may cause radio interference in which the user may be required to take adequate measures CAUTION Risk of electrical shock Do no
6. any omissions or inaccuracies in this manual please call 507 238 4461 and ask for a technical writer Installation Unpacking Maximum battery life with continuous backlight usage is approximately 12 hours on a full charge Without backlight enabled battery life is approxi mately 24 hours Recharge time is approximately 8 hours Unpack the scale and check for any obvious shipping damage Keep all packing materials and report any damage to your Weigh Tronix distributor immediately Models 3632B allows the transformer to be attached to the bottom of the scale or separated from the scale base Model 3634B s transformer is inter nal See Figure 1 for location of transformer E AOO S gt ia 2 LAdA l 2a LC f I I li Rer I ESNI eee ee i 1 l 1 l i 1 I re O1 O 1 I i ete Se Se eee ee 1 ke i vi i N iH 1 iN EE NAE te ee i It rl mi 4 on tol jy 1 l z A ki Li N 4 ks NN 15 h wA 1i i aS Li nil AS LI ra eee eee eran ae SOS a ee see SSS SSS SS 7 ajepe a Figure 1 TOP Transformer location on Model 3632B BOTTOM Transformer loction in Model 3634B 3600B Series Bench Scale User s Manual 5
7. by pressing the TARE key except in the case of the calibration error The scale must be recalibrated to continue ee Lower dashes mean the scale is below the initial zero range Upper dashes mean the scale is over capacity CAL Err Calibration error 3600B Series Bench Scale User s Manual 7 Communication e a O The 3600B series uses a DE 9 connector for EIA Standard RS 232 serial Connections communication Pinout for the DE 9 connector is as follows DE 9 Female Scale Your system uses one of two protocols Standard nCi Stn and 8213 The Computer to Scale Standard protocol is described below Serial Protocols Standard Protocol NCI Normal bidirectional Com puter Interface Key to symbols used lt ETX gt End of text character 03 hex lt LF gt Line Feed character OA hex lt CR gt Carriage Return character OD hex lt SP gt Space 20 hex x Character from display including minus sign hh Two or more status bytes uu Units of measure using ANSI standard abbreviations Commands Command Scale Response Results H lt CR gt lt LF gt xxxx xxuu lt CR gt Returns decimal weight in 10x Upper and lower case can be lt LF gt hh lt CR gt lt ETX gt with units plus scale status used W lt CR gt lt LF gt xXxxxxx lt CR gt Returns decimal weight lt LF gt hh lt CR gt lt ETX gt with units plus scale status lt LF gt hh lt CR gt lt ETX gt Returns scale status lt LF gt hh lt
8. d wire earth ground to insure proper operation and safety see note at left Upon power up the unit performs the following startup sequence e display shows model and revision level of software e display shows a segment test 3600B Series Bench Scale User s Manual Performing a Normal Weighment Using the Tare Function To clear a tare value empty the scale and press the TARE key Changing Unit of Measure Error Codes Follow these steps to perform a normal weighment 1 Press the ZERO key if the scale is not at zero weight Zero weight should be displayed 2 Place the item to be weighed on the scale platform The gross weight will be displayed 3 Remove the item from the scale Follow these steps to perform a weighment using the TARE key 1 Press the ZERO key if the scale is not at zero weight Zero weight should be displayed 2 Place the container to be tared on the scale platform The gross weight will be displayed 3 Press the TARE key The weight is tared zero weight is displayed and the NET annun ciator illuminates 4 Place the item to be weighed in the container The net weight will be displayed 5 Remove the items from the scale To change from one unit of measure to another press the UNITS key You can choose from pound kilogram and gram units of measure Below are the possible error codes you may see during operation of this scale You may continue with operation
9. e notes 2 3 lt STX gt STATUS lt CR gt See note 4 lt STX gt 0XX XX lt CR gt Pounds See notes 1 2 lt STX gt 0XX XX lt CR gt Kilos See notes 1 2 lt STX gt 0OXX XX lt CR gt Ounces See notes 1 2 lt STX gt S TATUS lt CR gt Zeros scale lt STX gt lt CR gt Scale test lt STX gt CONFIDENCE lt CR gt Confidence lt STX gt E lt CR gt Echo on lt STX gt F lt CR gt Echo off lt STX gt S TATUS lt CR gt Bad command Notes 1 The decimal point position may be different depending on selected ca pacity and division 2 Afixed leading zero is added to bring character count to the same as capacities with a decimal point 3 This supports the 1600 x 1 capacity which does not require the decimal point 4 Astatus byte is sent if the scale is in motion under zero or over capac ity 10 3600B Series Bench Scale User s Manual Quartzell is a registered trademark of Avery Weigh Tronix LLC Avery Weigh Tronix e _ Avery Weigh Tronix USA 1000 Armstrong Dr Fairmont MN 56031 USA Telephone 507 238 4461 Facsimile 507 238 4195 e mail industrial weigh tronix com www wtxweb com Avery Weigh Tronix UK Foundry Lane Smethwick West Midlands England B66 2LP Tel 44 870 90 34343 Fax 44 121 224 8183 Email info awtxglobal com Web site www averyweigh tronix com Avery Weigh Tronix Canada ULC 217 Brunswick Boulevard Pointe Claire QC H9R 4R7 Canada Telephone
10. t remove cover No user serviceable parts inside Refer servicing to qualified service personnel Weigh Tronix reserves the right to change specifications at any time 02 15 05 3600SC_U indd PN 29705 0015G e1 Printed in USA LELIA EL WIPED NO DOI 25 on e E E E E T 5 Instalati iieiea e O E E E 5 CUTS FMVS mesen e eE EEEE A E EEEE e tom EE E 5 Display and COmtrOlS sereas reisene eE EErEE 6 KEY Sinatria reren aa aa e lots a a aE E cies dels Eaa e 6 Operating the Scale socere rar Eeee aar EE EER OE SAE ERE RESER OE SE 6 Powering Up the SCA tthe ees sat pce eagerness EEEE 6 Performing a Normal WIQhiMienitl ccscics a dedecenactindeeimenlederd div yerrnctn de Sate deasiededences 7 Using the Tare CI WN sgecaicestiesedeuedenduec5sesSastsendcelssdeebeendeede identdecdaesaebaucceance bende 7 Changing Unit of WAS Sc creases dcemnsnonsenccadsseacienetmentnenecetecetamenndaxaddacstxesvaueueabbe 7 Emor COdOS ce meyer oe er ee E ner rere ee eer ere 7 Communications soeter cco ren itr herr E rr ner err nr rrr er mee fee eee A ere 8 MS NSS WON asia A E E E E 8 Computer to Scale Serial Protocols wceteiesessacsncaniastenastapernatxncecadenauslamelgucczerszsvateevoses 8 Standard ag 6 0 616 een neem a tee ene arei eae ee ene ne noe i nee aeaaaee 8 Optional 8213 PROVO sssrini rera E a pa 10 IMPORTANT J ILLLLLLLLLLLLEG This equipment must be routinely checked for proper operation and calibration P Application and usage will determine the frequenc
11. y of calibration required for safe operation IJIIIIIIIILLIIA L Pages are numbered consecutively beginning with the cover page 3600B Series Bench Scale User s Manual 3 Specifications Capacity and Dimensions Construction Display Units of measure Controls Display dimensions Power Power cord Environment Agencies Model Capacity Dimensions _ 3632B _ 10lb 5kg 12 x 14 3632B 50 lb 25 kg 12 x 14 100 Ib 50 kg 3634 250 Ib 150 kg 18 x 18 Model 3632B 10 has an 8 dia round stainless steel platter Model 3632B Die cast aluminum with stainless steel shroud Model 3634B Mild steel with stainless steel shroud Seven digit liquid crystal display 0 5 inch digits with blue electro lumines cent backlight lb kg g selectable from scale display ZERO key PRINT key TARE key GROSSINET key UNITS key Ib kg g 9 5 wide 3 25 high 24 cm x 8 25 cm front mounted Input 120 VAC 10 60 Hz 0 1 amp maximum Output 15 VDC 3 amps DC minimum Battery Option 6 ft 1 83 meters 10 C to 40 C 14 F to 104 F NTEP Certificate 95 071A2 CSA Pending UL Pending 3600B Series Bench Scale User s Manual Introduction The 3600B series of bench scales uses the Quartzell weight transducer for higher resolution and greater weighing accuracy This manual covers the installation and operation of the different size and capacity scales that make up the 3600B series If you find