USER MANUAL - Intelligent Security & Fire Ltd

image

Contents

1. Press key to finish This feature is only active when enabled by your installer Quick check Zones that cannot have chime are CHIME ON CHIME OFF Press Press Key in zone Key in zone light will come on Light will go out Press to finish Press to finish 13 0 LOGS The Control panel has the ability to look at the last set and unset conditions of the panel as well as the last alarm conditions This is useful if the panel has been reset and you need to find the zone that caused the alarm To do this enter user code 1 or 2 and press then 9 then 3 You will hear a continual tone which denotes you are viewing the last set condition There may be no lights illuminated as there may not have been an alarm during the last set condition Pressing the key will turn off the sounder and show the last unset condition By now pressing 0 you will show the last ALARM condition that was during an UNSET period no matter how long ago that alarm was Pressing will bring the sounder back on and will show the last ALARM condition during a SET period Press to finish Quick check Enter code then 9 3 Now showing last set condition Sounder ON Press to show unset event s Sounder OFF Press 0 for last alarm condition when unset Sounder OFF Press to show last alarm condition when set Sounder ON Press to finish Light on constant alarm activation Light pulsing fast subsequent alarms Light pulsing slow zone was i
2. speaker changes to rapid pips then you have less than 10 seconds to disarm the system 5 0 TAMPER FAULTS Your control panel is equipped with a common tamper circuit giving protection from unauthorised handling If the tamper circuit is broken during any unset period the internal sounder will trigger and the tamper light will illuminate Proceed directly to the panel or any remote keypads and insert your user code the internal sounder will stop and revert to a low two tone sound Press the key the panel will reset if the tamper light continues to flash then the cause of the tamper condition is still present Now refer to fault clearing section 15 0 6 0 DISARMING AFTER AN ALARM 6 0 1 AFTER THE PANEL HAS AUTO RESET Enter the protected area by the authorised entry route an intermittent tone will be made from the speaker proceed directly to the control panel or keypad and insert your user code the system will disarm the zone s will light on the control panel to indicate the cause of the alarm refer to panel reset section 14 0 to clear the panel The first to alarm will show a constantly illuminated light Subsequent alarms are shown as fast flashing lights Zones that were isolated are shown as slow flashing lights 6 0 2 WHILE PANEL IS IN ALARM Go directly to the control panel or remote keypad and insert your user code the system will disarm the zone s will light on the control panel to indicate the cause of the alarm ref
3. H CONDITION IN 5 SECOND INTERVALS Strobe Panel clears Test Ended 11 0 WALK TESTING It is advisable to check that the detection devices are communicating with the panel This kind of testing should be performed every 3 months To do this go to the panel or remote keypad enter user code 1 or 2 then press then 9 then 4 the internal sounder will give a single pitched sound when any detector is triggered or contact opened the internal sounder will give a loud pulse and the zone light will illuminate Clear the detector or close the contact and the sound will revert back to the single pitched sound proceed to the next detector or contact until you have completed all the zones when you are satisfied with the walk testing press to exit the walk test mode Quick check Zones that cannot be walk Tested are Enter code then 9 4 Fire Walk test the zones PA Press to finish Tamper 12 0 CHIME A feature of the Control panel is the ability to have chime on a zone when the panel is unset This feature will emit a chime tone via the speaker whenever a zone is activated To achieve this press the key and the number key that represents the zone s you want on chime The light for the zone will illuminate Press to accept the zones on chime To remove a zone on chime press the key and the zones will light up that are currently active Press the key that represents the zone the light will go out chime is now disabled on that zone
4. Try again with a different code Check your new code is functioning correctly by performing a full or night set then abort by pressing To change user 2 code go through the above procedure but press then 9 then 2 Panel Default Code is 1 2 3 4 for user 1 code User 2 code is disabled by default PERSONAL ATTACK FROM REMOTE KEYPAD CODE CHANGE SOUNDER TEST WALK TEST User code access levels User 1 code can alter both user codes User 1 code can disable user 2 code To disable user 2 code changed user 2 code to 0000 User 2 code has the same setting rights as the user 1 code User 2 code cannot alter the user 1 code If for any reason you loose your code or mistype in a code when changing it the installer will need to be contacted to default the panel codes 10 0 SOUNDER TESTS It is advisable to check the system is working correctly every week and especially the sounders To do this go to the panel or remote keypad enter a user code then press then 9 Each of the tests lasts for 5 seconds All the lights on the control panel will illuminate then the lights will go out and the internal siren will activate proceed outside where the external sounder is fitted The external sounder will trigger then the external strobe will flash if fitted and enabled and then the panel will clear down The test is now complete QUICK CHECK Enter code then 9 All lights on Internal sounder External Sounder EAC
5. USER MANUAL CHALLENGER VIII CONTROL PANEL 5 05 1 718 00 WARNINGS TU T Z I G MLL Ze K A i i a fe S 3 CE This product has mains voltage present within the housing Please take the necessary precautions in not allowing any liquid to spill on or into the housing There are no user serviceable parts inside this product STANDARDS This unit conforms to ECD 89 336 EEC amp LVD 73 23 EEC This unit has been tested to the required standards for emission immunity and LVD regulations as set out by the EEC This unit complies with EN50131 1 which relates to security control equipment PRODUCT DESCRIPTION The Control panel is an 8 zone programmable microprocessor control panel using state of the art technology and building techniques The Control panel has many advanced features that can only be found in more expensive control panels such as two user codes Chime Fire and Keypad PA There are many options in the programming functions to allow the control panel to be versatile and user friendly This allows the Control panel to be the ideal choice of your installer This product has been carefully designed and tested to give many reliable years of service please make sure the Control panel is regularly serviced at least once a year by your installer INSTALLER INFORMATION NAME COMPANY INSTALLATION DATE MOBILE OTHER INFORMATION Ma
6. er to panel reset to clear section1 4 0 The lights follow the same descriptions as above in section 6 0 1 7 0 PERSONAL ATTACK If your system has a personal attack button fitted this will be linked into the alarm system as a 24hr device This means the PA button will be live all the time If the PA is pressed all the sounders will operate and bring up the zone light programmed as PA Proceed directly to the panel or any remote keypads and insert your user code the sounders will stop and revert to a low two tone sound press the key the panel will reset if the zone light continues to flash then the cause for the personal attack condition is still present Go to the personal attack button s and reset with the special key provided the zone light should go out If the light continues to flash refer to fault clearing section 15 0 Note If the panel is armed and a PA is activated you will need to disarm the system as explained in section 6 3 7 0 1 PERSONAL ATTACK FROM REMOTE KEYPAD If your installer has fitted you a remote keypad then the amp key can be programmed by the installer for personal attack If this is the case then pressing and holding the amp key together will activate the alarm system as in 7 0 The only difference is that the tamper light will illuminate Insert your user code the sounders will stop and revert to a low two tone sound Press the key and the panel will reset 8 0 FIRE Your installer
7. may have linked some smoke detectors to the control panel these act very similar to PA devices with the exception that when activated in an unset condition the internal sounder will give a loud whooping sound and the external sounder will pulse in 2 second intervals When the panel is set the external sounder will constantly sound Make sure that every one exits the premises When you are sure that it is safe to return back proceed directly to the panel or any remote keypads and insert your user code The sounders will stop and revert to a low two tone sound Press the key the panel will reset USER FUNCTIONS amp OPTIONS 9 0 CODE CHANGE There maybe times that you need to change your user code There are 2 user codes that can be utilised To help you remember your new code write it down before changing it and after you have successfully changed and memorised the code destroy the written code Remember try not to use obvious codes such as 1066 or the current year To change user code 1 from the panel or remote keypad enter your existing user 1 code then press then 9 then 1 four lights will illuminate enter your new 4 digit code For every digit pressed of your new code one light will extinguish Once your new code is entered the panel will give you an accept tone if the panel does not accept your code then you may be in conflict with user code 2 or the engineering code the panel will abort the code change and retain your old code
8. nufactured For City Electrical Factors By C amp K Systems Ltd 1 0 FULL SET To fully arm the system insert your user code then leave the premises by the authorised exit route The continuos exit tone will sound from the control panel and from any remote keypads fitted Any pulsed tones should return to a continuous tone once you have left the building and the sensors have cleared The control panel will arm after the exit timer has run out at this point the tone should cease If for any reason the tone does not go continuous after all the sensors have cleared return back to the panel or remote keypad and press to abort the setting procedure If the internal sounder activates after the timer has expired return back to the control panel or any remote keypad and insert your user code and press Now refer to fault clearing section 15 0 2 0 NIGHT SET To night set the system insert your user code and then press then 0 The zones pre programmed to be isolated will start to flash and the internal speaker and any remote keypads will emit a low pitch continuos tone If any zones are activated while leaving the protected area the sound will change to a pulsed tone These should return to a continuous tone once you have left the protected area and the sensors have cleared The control panel will arm after the exit timer has run out and the tone should cease If for any reason the tone does not change to continuous after you have left the
9. protected area press to abort the setting procedure If the internal sounder triggers after the panel has set return back to the control panel or any remote keypad and insert your user code and press Now refer to fault clearing section 15 0 2 1 HOME SET To home set the panel enter your code followed by 8 This will isolate any chosen zones programmed for isolation Please note that this setting method can allow the isolation of ALL entry routes Follow the above paragraph for guidance regarding exit tones etc 3 0 MANUAL ISOLATION OF ALARM ZONES There maybe occasions when you need to isolate zones other than the zones pre programmed arm the system as in 1 0 or 2 0 then press then the zone number you wish to isolate That zone will flash indicating a successful isolation if you want more zones isolated press and another zone If any zone is barred from isolation an error tone will be emitted Zones that cannot be isolated Fire PA Tamper Zone 1 in Full Set Zone 8 FULL SET NIGHT SET ZONE ISOLATION DISARMING TAMPER DISARMING AFTER AN ALARM WHILE PANEL IS IN ALARM PERSONAL ATTACK 4 0 DISARMING THE SYSTEM Enter the protected area by the authorised entry route a single continuous tone will be made from the speaker and from any remote keypads fitted Proceed directly to the control panel or keypad and insert your user code whereby the system will disarm If the entry tone from the
10. solated 14 0 RESETTING THE ALARM SYSTEM If the alarm system has activated you will need to reset the panel make a note of the zone that caused the activation for future reference Insert your user code the internal sounder will give a low two tone sound press the key and an accept tone will be given and the activated zone light will go out and the panel will reset The system is now ready for use 15 0 FAULT CLEARING SYMPTOM CAUSE ACTION Zone light on continuos in da continuos our installer exit time Alarm triggers on entry Timer ran out Follow entry procedure call your installer to deviated from entry extend entry time route blown call electricity supplier or installer over OO ZONENo AREA COVERED Please Note We are always endeavouring to improve quality and specification of all products To this end we may alter or amend this product and instructions without notice