E5AN-HT/E5EN-HT Programmable Temperature - Innovative-IDM

image

Contents

1. H L N H Input Type Adjustment Press the O Key less than 1 s gm a co Level PEERS Ef Operation Level 4 em mm EL N H Scaling Upper Limit Press the LO Key less than 1 s em dmn E G Process Value g fi G RUN STOP j e H 5 Added when Additional Br B LN 1 Scaling Lower Limit a55 PV display is ON EEG ALIN 5 z NE Ve m x ae 72 i o I Adl Ea roy N G Temperature Input Shift g7 5 Process Value B70 Alarm Value 1 D e l BE entering a 4 Set Point as E E B c P Decimal Point 000 Sec LI EE LI m J co adjustment level co 1 point shift i S EB fi For input type of analog Exo 9 a Bt ni U Upper Limit Set either Su p M Auto Manual Switch E
2. Setting Level Input Type Transfer Output The time taken to move to the protect level s LU Pacer imit can be adjusted by changing the Move to Displayed only for models with communications Changes protect level time setting are effective after cycling power or after a software reset EH tM Z I Move to Protect Level 1 v D I ICIN Displayed only when a password Protocol Setting 8 Scaling Upper Limit Transfer Output m n is set Restricts moving to protect B P5EL Switches between 8 Lower Limit Eon H level E rur CompoWay F and HH Iu co Modbus B 412M2 Communications B Scaling Lower Limit 3 U No MERI B N 1 9 S Linear Current Output pnm a B 3 Operation Adjustment EBD ul a ONIN L Protect co i B oO r E NT B Be Baud Rate i j Decimal Point co Enn 9 6 compete E d P E Event Input y CIO n H Assignment 1 B p pj Initial Setting ES y E z nt aes L L T L Communications Protect B L EN Communications J col oom M E Data Length 200 LI 1 a _4_ 14 Temperature Unit g OTL H Pvent Input a ec 8 ssignment 2
3. Alarm SP Selection Remote SP Enable Remote SP Upper Limit Remote SP Lower Limit SP Tracking Remote SP Input Error Output PID Set Automatic Selection Data PID Set Automatic Selection Hysteresis PV Dead Band Manual MV Limit Enable Direct Setting of Position Proportional MV PV Rate of Change Calculation Period Automatic Cooling Coefficient Adjustment Heater Overcurrent Use Heater Overcurrent Latch Heater Overcurrent Hysteresis PF Setting Monitor Setting Item 1 Monitor Setting Item 2 Monitor Setting Item 3 Monitor Setting Item 4 Monitor Setting Item 5 PV SP Display Screen Selection MV Display Selection PV Decimal Point Display PV Status Display Function SV Status Display Function Display Refresh Period Control Output 1 ON OFF Count Monitor Control Output 2 ON OFF Count Monitor Control Output 1 ON OFF Count Alarm Set Value Control Output 2 ON OFF Count Alarm Set Value ON OFF Counter Reset Move to Calibration Level OMRON Programmable Type E5CN HT E5AN HT E5EN HT
4. Press the O Key or the PF Key for at least 1 s 4 4 Press the Of Operation Adjustment ce Keys for at Level Level ress least 1 s Press the the O c O_LM_ v Ol Key less than 1 s Press the ce Keys E RES O Key less for at Ses N Press the eso d least 3 s Of Key less than 1 s Display Press the O Key Will flash for at least 3 s while after 1st H M is displayed PID Setting Bank Setting d Manual FR will flash after L L second 1st second eve P th eve mode X3 ress the O Key less J than 1 s Press the PF Key for at least 1 s k4 Manual EE Protect Level Control Level Monitor Setting ey PF Key Item Level 5 Note The time taken to move to the protect level can be adjusted Press the LO Ke ey 10 for at by changing the Press the O Key least 3 s Display will flash Move to protect level tarat least 1 5 after 1st second time setting x miai seni Communica Control stops due Sung tions Setting Press the Level O Key for less than 1 s Press the O Key Input password while Oma Hn is displayed Set value 169 Advanced Function Setting Level Input password for at least 1 s C Control in progress CJ Control stopped Calibration Level Not displayed for some models qe Level change 1 Y
5. 100V 50 Hz Distor factor gt 7 1 kQ 10 u 500 Q 3 v 1 1 O f g 4100 mV g 100 Q 6 5 Q 10 RL 21020 1 100 uV 10 1 10 100 mA 1 10 100 1 000 A Thru current lo A r m s OMRON Operation Setting Levels Diagram Operation for E5_ N E5_ N H E5_ N HT Operation for E5_ N E5_ N H E5_IN HT CSM E5 N E5 N H operation TG E 3 3 This diagram shows all of the setting levels To move to the advanced function setting level and calibration level you must enter passwords Some parameters are not displayed depending on the protect level setting and the conditions of use Control stops when you move from the operation level to the initial setting level Basic Type E5CN E5CN U E5AN E5EN E5GN Start in manual mode Power ON Start in automatic mode Press the O Key or the PF Key for at least 1 s 4 Operation Adjustment D M Press the c MI OJ Key less than 1 s see A PF Key Press the O Ke x5 Manual Er at least 3 s while Monitor Setting A M is displayed mode m A M will flash after kd Key Item Level 1st second 4 Press the PF Key Manual for at least 1 s Control Level Press the Key for at least 1 s O Control stops Press the for at least 1 s T O Press the LO K
6. Program Time Unit Step Time Rate of Rise Programming Time Unit of Ramp Rate Reset Operation Operation after Power ON Operation at End of Operation PV Start Move to Advanced Function Setting Level OMRON Operation for E5 N E5 N H E5 IN HT mes MON Manual Control Level oC MN fi ee ee ee ee E E I a I a O ti P Setti Ad PID Sett Monitor Setti peration rogram Setting justment etting onitor Setting Protect Level L Level Level Level Level Item Level i H 8 L Q a F a P a 7 8 i SSSSSSSSSSSSSSSSIPOSSSSCSSSSSSSSSSESSTSOSSSSSSSVSSSSTSESSSESSSSSSSSSSESeOssescsoeseaeaeusesenaea dd ESS SEE AO SS SS n 1 Communica 4 tions Setting i 8 Level L Lawson am mmw ueaamewu E a wm Advanced Function Setting Level Press the O Key for at least 1 s gt Advanced Function Setting Level Parameter Initialization Auxiliary Output 1 Monitor Setting Item 1 Cold Junction i Assignment Compensation Method DB 0000 Auxiliary Output 2 Monitor Setting Item 2 Standby Sequence PV Change Color ei 3 Assignment Reset DD 0000 HP NP 7 C o Fun c s Auxiliary Output 1 e PV Stable Band Open in Alarm Auxiliary Output 3 g Monitor Sett
7. Manual MV Control Output 1 Limit Enable ON OFF Count Alarm Set Value Additional PV Display HS Alarm Use Direct Setting of Control Output 2 Position Proportional MV ON OFF Count Alarm Set Value MV Display HS Alarm Latch Return Time Calculation Period REESE ce Automatic Display HG H HS Alarm Hysteresis PV Rate of Change ON OFF Counter 1 je i m gE u Alarm 1 Latch LBA Detection Time Automatic Cooling Program End ON Time Coefficient Adjustment aue Evich LEA leval Heater Overcurrent Standby Time Uni Use Heater Overcurrent Program SP Shift Alarm 3 Latch LBA Band Value Addition Latch ALL GFF Move to Protect Level Control Output 1 Heater Overcurrent B RSP Broken line Correction Time i i Assignment ux j Hysteresis Display Addition Input Error Output Control Output 2 PF Setting Move to Calibration Assignment OMRON Safety Precautions for E5 IN E5 IN H E5 IN HT Safety Precautions for E5 IN E5 IN H E5 IN HT osu tsn cs nu cn 32 Safety Precautions Refer to Safety Precautions for All Temperature Controll
8. Heater Overcurrent Hysteresis settings Detection 2 Hysteresis Cooling Leakage Current 1 Monitor Wait Band HS Alarm 1 MV at Reset Leakage Current 2 Monitor O Key less than 1 s MV at PV Error MV Upper Limit MV Lower Limit MV Change Rate Limit Position Proportional Dead Band Open Close Hysteresis Extraction of Square Root Low cut Point Standby Time Program SP Shift Value RSP 0 before Correction RSP 1 before Correction RSP 10 before Correction RSP Broken line Correction Value 0 RSP Broken line Correction Value 1 RSP Broken line Correction Value 10 OMRON Operation for E5 N E5 N H E5 IN HT KORON Starting in manual mode Manual Control Level Press the PF Key asn Deal Sa the 2 Key Starting in for at least 1 s k tes 1000 e ss u a automa PV MV Press the O and kel Keys for at least 3 s Press the O Key less than 1 s Program Setting Level Ly Operation Level Operation Level Press the O Key for at least 3 s Display Program Selection ee Bo PPG i a ER df
9. Heater Current 2 Value Monitor Number of Segments Used 1 to 32 ud Leakage Current 1 See note Value Monitor Display Segment Selection END or 0 to Number of Segments 1 c Bd SEG coo I Auto Manual Leakage Current 2 Switch Program Number Run Reset Press the O and el Keys for at least 1 s PID Set No Segment n Format Segment No MV Monitor Heating Monitor Alarm Value 1 Segment n SP Hold MV Monitor Cooling 000000 Alarm Upper Limit 1 SS Advance Valve Opening Monitor 00 0000 Segment n Ramp Rate ES EM 5 Alarm Lower lar Remaining Standby Limit 1 Segment n Time Time Monitor 000000 E3p zx F3 rm i Elapsed Program Alarm Value 2 Time Monitor Co Ea co Program Link Destination Program Execution Repetition Monitor tn 0000 rc Alarm Upper Limit 2 iE Time Signal 1 Alarm Lower Set Segment Limit 2 a Remote SP Monitor Bp 0000 E c3 t3 Time Signal 1 ON Time Heater Current 1 Value Monitor Alarm Value 3
10. Power supply Bus power Supplied from USB host controller Power supply voltage 5 VDC Current consumption 80 mA Ambient operating temperature Ambient operating humidity 0 to 55 C with no condensation or icing 10 to 80 Storage temperature 20 to 60 C with no condensation or icing Storage humidity 10 to 80 Altitude 2 000 m max Weight Approx 130 g with mounting adaptor Note A driver must be installed in the personal computer Refer to installation information in the operation manual for the Conversion Cable Heater Burnout Alarms SSR Failure Alarms and Heater Overcurrent Alarms Models with detection for single phase CT input for heater current detection heaters One input Models with detection for single phase or three phase heaters Two inputs Maximum heater current 50A AC Input current indication accuracy 5 FS 1 digit max Heater burnout alarm setting range 1 SSR failure alarm setting range 2 Heater overcurrent alarm setting range 3 0 1 to 49 9 A in units of 0 1 A Minimum detection ON time 100 ms 0 1 to 49 9 A in units of 0 1 A Minimum detection OFF time 100 ms 0 1 to 49 9 A in units of 0 1 A Minimum detection ON time 100 ms 1 For heater burnout alarms the heater current will be measured when the control output is ON and the output assigned to the alarm 1 function will turn ON if the heater current is lower th
11. Time Signal 1 Alarm Upper OFF Time Limit 3 Time Signal 2 Set Segment Alarm Lower Limit 3 Time Signal 2 ON Time Program n Repetitions PF Key 2 Monitor Setting Item Level ESAN EN HT only a p amp Monitor Setting PF Monitor Setting PF g Monitor Setting cm gg Item Display 1 Item Display 2 m Item Display 3 PF Time Signal 2 OFF Time Monitor Setting PF E Monitor Setting Item Display 4 gt h Item Display 5 g Note The monitor setting items to be displayed is set in the Monitor Setting Item 1 to 5 parameters advanced function setting level PF Key 2 1 When the PF Setting parameter is set to A M for a Controller with a PF Key EBAN EN HT 2 When the PF Setting parameter is set to PFDP for a Controller with a PF Key EBAN EN HT OMRON Operation for E5 N E5 N H E5 IN HT Press the O Key for at least 1 s Press the O Key for at least 3 s Other than the Auto Manual Switch display Initial Setting Level Press the O Key less than 1 s Press the O Key less than 1 s Communications Protect Level
12. Bank 7 e LALE ce Alarm Value Bank 7 Upper Limit 1 gms idc 3 H RLIE PID 8 Automatic Selection d jen Um E 3377 Range Upper Limit IC co Em 1920 0 ge pp Bank 7 e ICSE ce Alarm Value Bank 7 B Lower Limit 1 Em 100 8 BLFGI PID 8 Cooling Coefficient n are B L IL Br m Lower Limit 3 Ee Em 100 d 5 UR ce ER c Bank 7 Soak Time 200 LI B AL hA PID 8 LBA Detection Time co Em n Bank 7 Wait Band OMRON I l L Add FMltl LI d Im BFF Adjustment Level Adjustment Level Display Displayed only once when entering adjustment level AT Execute Cancel Communications Writing Infrared Communications Use Heater Current 1 Value Monitor Heater Burnout Detection 1 Heater Overcurrent Detection 1 Heater Current 2 Value Monitor Heater Burnout Detection 2 Heater Overcurrent Detection 2 Leakage Current 1 Monitor HS Alarm 1 Leakage Current 2 Monitor HS Alarm 2 Temperature Input Shift 1 point shift lt gt Upper Limit Temperature Input Shift Value 2 point shift Lower Limit Temperature Input Shift Value Set either of these param eters
13. Op Starting in ma Manual Control Level eration for E5 IN E5 IN H E5 IN HT ime 11810 nual mode PID Press the O Press the PF Key for at least 1 s x 8 35 8 Control Starting in Bem a Key or the PF automatic Key for at least mode 1s 1 Press the O and el Keys for Press the C Key less than 1 s pnmum EF Operation Level ae pu Process Value A G B U Added wh
14. Some parameters are not displayed depending on the model of the Controller and parameter settings For details refer to the ESCN HT E5AN HT E5EN HT Digital Controllers User s Manual Programmable Type Cat No H169 KOAN Manual Control Level Operation for E5_ N E5_ N H E5_ N HT Operation Protect Level Level Program Setting Level Adjustment Level PID Setting Level Monitor Setting Item Level P a 1 4 1 a 1 Initial Setting Level O Press the Display PID Selection PID1 l4 tions Setting Key less than 1 s Communica Level O Press the Key less than 1 s PID 8 Proportional Band PID 8 Integral Time PID 8 Derivative Time PID 8 MV Upper Limit PID 8 MV Lower Limit PID 8 Automatic Selection Range Upper Limit PID 8 Cooling Coefficient PID 8 LBA Detection Time Adjustment Level Adjustment Leve Seem awanteaenaaeananaaeaeaean Press the HS Alarm 2 Temperature Input
15. after 1st second Press the O Key for less than 1 s Input password while HMav is displayed Set value 169 Advanced Function Setting Level Input password Calibration Level Key 2 1 You can return to the operation level by executing a software reset 2 It is not possible to move to other levels from the calibration level by operating the keys on the front panel It can be done only by first turning OFF the power 3 From the manual control level key operations can be used to move to the operation level only 4 When the PF Setting parameter is set to A M for a Controller with a PF Key E5AN E5EN 5 When the PF Setting parameter is set to PFDP for a Controller with a PF Key E5AN E5EN Error Displays Troubleshooting When an error occurs the No 1 display shows the error code Take necessary measure according to the error code referring the table below ey for at least 3 s Display will flash Press the Of ce Press the Keys for at Ol ce least 1 s Keys for at Note The time taken to move to the protect level can be adjusted by changing the Move to protect level time setting Control in progress Control stopped Not displayed for some models Level change Status at error No 1 display Meaning Action Control output Alarm output Ecoo Input error Check the setting of the input type Also check the
16. for at least 1 s k4 Manual Control Level Protect Level Monitor Setting PF Key kS PF Key Item Level 5 Note The time taken to move to the protect level can be adjusted Press the O Key for at by changing the Press the O Key least 3 s Display will flash Move to protect level forat least d after 1st second time setting 1 EIE Communica Control stops ee etting tions Setting Press the Level O Key for less than 1 s Press the OI Key Input password while for at least 1 s Hav is displayed Set value 169 Advanced Function Setting Level 2 Calibration Level 1 You can return to the operation level by executing a software reset 2 It is not possible to move to other levels from the calibration level by operatin OFF the power Input password C Control in progress CJ Control stopped __ Not displayed for some models qp Level change g the keys on the front panel It can be done only by first turning 3 From the manual control level key operations can be used to move to the operation level only x4 When the PF Setting parameter is set to A M For the ESCN HT press the co A A Keys at the same time to implement the PF Key cel 5 When the PF Setting parameter is set to PFDP For the ESCN HT press the Error Displays Troubleshooting A Keys
17. i co ES ms d n Ss LL bt Communications Bm Setting Change Protect S Shek s 3 NEPLE g Chang B Stop Bits i s B Eu ZEC p d EE ofi setti H 8 Event Input Se sete B Assignment 3 Ec e PNE Communications Parity ESTEE g B prr PF Key Protect pum EWEN ca B co Cis EMEN are ac Bi B SP Lower Limit g Event Input 200 AL L 1 S Owe Send Data Wait Time EIS annn s SSMS co sl LN 2o00 cb EE Co B pM E 1 4P8rameter Mask Enable co B D RET L1 PID ON OFF EE oN EE Closed Floating Pid D omn rm r4 Password to Move to a OO TI LII Standard or oriwee Ru d T ti Heating Cooling Motor Calibration Bea Nd co co Control Period Heating Travel Time o0 0000 Extraction of Square Root Enable Control Period Cooling OO 0000 Direct Reverse Operation Alarm 1 Type Alarm 1 Hysteresis Alarm 2 Type Alarm 2 Hysteresis Alarm 3 Type J goo 0000 Du 0 Alarm 3 Hysteresis oe E oO rr og Transfer Output Type 4 OO 0000 oo Lt Di a i ntl n gt zl ri 4
18. or PV MV Errors are not shown for any other status OMRON Operation for E5 N E5 N H E5 IN HT Parameters Basic Type E5CN E5CN U E5AN E5EN E5GN Some parameters are not displayed depending on the model of the Controller and parameter settings For details refer to the ESCN E5AN E5EN E5GN Power ON Digital Temperature Controllers User s Manual Basic PF Key 2 Type Cat No H156 Starting in manual mode Starting in Press the O Key for at least 3 s PF Key K2 Manual Control Level automatic Other than the Auto Manual Switch display Press the PF Key for Bresse thao mode Initial Setting Level e atleast 1 s 1 3 M i Key ubl P Press the Press the O Key less than 1 s cm ony fais Ol Key for at least 1 s i PV MV x1
19. rini ON OFF nter 5 Py Hg Additional PV Display MV at Stop and Error 2 rrr p Automatic Cooling H RRC SEV Hd Addition ELSL HR S Reset ce EF E SEF Coefficient Adjustment EES g 1 co co ES a Heater Overcurrent B I M Move to Calibration H5 HPBNIBSD Auto Manual Select 8 aL LI vercu a LMOV i evel snm ug play Addition es o IZM Use Bec Aes OFF i l a H E I Automatic Display z n L Heater Overcurrent S pp Return Time t X prp Latch enu CI ore lee E a r H Heater SEA E ni Hysteresis co OMRON Operation for E5_ N E5_ N H E5_ N HT Advanced Type E5CN H E5AN H E5EN H Some parameters are not displayed depending on the model of the Controller and parameter settings For details refer to the ESCN H E5AN H Power ON E5EN H Digital Controllers User s Manual Advanced Type Cat No H157 eeeeeoaecieoee eeeeeceoe eoo eeeaeoeoeo e ecce 2 eeeaeaeoaeaeeeeeeececeoeooeeceecoeenoeceoeoeoeoeoeoeoeeeoeoedy 9 6 eee Operation Adjustment Level Bank Setting Level Level PID Setting Level Monitor Setting Protect Level Item Level ocooowo eee Se ELI occoocooocoooooo e Seeeeeeeneeeeeeeeeeeeaeoeaenoeoeoaooanoeaeoae2oesa gageeeeo eeae eeeeaeaeaeaeaeoaeean Communica tions Setting Level Advanced Function Setting Level Press the O Key less than 1 s PID Setting Level Bank Setti
20. 0 to 3240 0 s in units of 0 1 s Control period 0 5 1 to 99 s in units of 1 s Manual reset value 0 0 to 100 096 in units of 0 196 Alarm setting range 19999 to 32400 decimal point position depends on input type Affect of signal source Thermocouple 0 1 C Q max 100 Q max resistance Platinum resistance thermometer 0 1 C Q max 10 Q max Insulation resistance 20 MQ min at 500 VDC Dielectric strength 2 300 VAC 50 or 60 Hz for 1 min between terminals with different charge Vibration Malfunction 10 to 55 Hz 20 m s for 10 min each in X Y and Z directions resistance Destruction 10 to 55 Hz 0 75 mm single amplitude for 2 hrs each in X Y and Z directions Shock Malfunction 100 m s 3 times each in X Y and Z directions resistance Destruction 300 m s 3 times each in X Y and Z directions Weight Controller Approx 310 g Mounting Bracket Approx 100 g Controller Approx 260 g Mounting Bracket Approx 100 g Degree of protection Front panel IP 66 Rear case IP 20 Terminals IP 00 Memory protection Non volatile memory number of writes 1 000 000 times Setup Tool CX Thermo version 4 0 or higher Provided on the bottom of the E5AN HT and E5EN HT An E58 CIFQ1 USB Serial Conversion Cable is required to connect the computer to the ESAN HT and E5EN HT Provided on the front of the E5AN HT and E5EN HT An E58 CIFIR USB infrared Conversion Cable is required to connect the computer t
21. AB B pp Monitor D P E B OL ST Self tuning y 200 tL ooo Li a 5 G Des ZN For input type of Ja Heating cooling co E e i temperature standard m n control or PID seer Tell FI db RN E T Rg Leakage Current 2 E AL JH Alarm Value g a Scu e Dg ng Monitor p LJ Uppertimits g PE IN Program Pattern LILI Ber Lu 2 en i co co co 2 mu oF F When assigning PID or o control output to ON OFF Heater Overcurrent gF R Manual Reset Value Program Start gt Hi 41 Alarm Value o output Detection 2 E Clear the offset during q IL AC ower Limit 3 22 aaa B stabilization of P or PD DEP n 1 ce control Control Period Heating co Leakage Current 1 E7 H5 Hysteresis Heating Soak Time Remain Set the ON OFF NEW a H45 i ri MV Monitor Heating output cycle 5 a D Control Period Cooling co Hysteresis settings Fi B HG 1 HS Alarm 1 Truc Hysteresis Cooling H g MV Monitor Cooling a BH LN gsm 500 i Emm nn Direct Reverse Operation Yee 8 gl Leakage Current 2 5a Hit Soak Time a _ Monitor H ul Bs the O and kel Keys for 5 Press the O Key Alarm 1 Type at least 3 s Press the O and Ee Keys for at least 1 s less than 1 s HS Alarm 2 Wait Band Protect L ommunications JONES LR Setting Level LM Note The time taken to move to the protect Note Displayed only for models with communications a HL Hi 4 level can be adjusted by changing the Changes are effective after cycling power or co poe MV at St
22. ESAN H E5EN H and E5AN HT E5EN HT Note Estimates can be provided for coatings and other specifications that are not given in the datasheet Ask your OMRON representative for details pem Ser 3 l 3 This data sheet is provided as a guideline for selecting products Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product E5CN HT E5AN HT E5EN HT Digital Controllers User s Manual Programmable Type Cat No H169 E5CN HT E5AN HT E5EN HT Digital Controllers Communications Manual P rogrammable Type Cat No H170 E5AN HT Case Size color 1 4 DIN 96 x 96 x 78 Black WxHxD ESEN HT Case Size color 1 8 DIN 48 x 96 x 78 W xH xD Power E5AN HT E5EN HT Ordering Information Optional functions Control Auxilia Heater supply mehed Ed Control output 1 2 burnout Event Transfer EOS Model voltage inputs output Control Output Unit x 2 ns E5AN HTAA2HBM 500 4 to 20 mA 4 to 20 mA Control Output Unit x 2 output input E5AN HTAA2HHBFM 500 100 to 4 to 20 mA 4 to 20 mA 240 VAC Control Output Unit x 2 output input E5AN HTAA3BFM 500 Relay outputs x 2 ae E5AN HTPRR2BM 500 4 to 20 mA 4 to 20 mA Relay outputs x 2 output input E5AN HTPRR2BFM 500 Control Output Unit x 2 nu E5AN HTAA2HBMD 500 l 4 to 20 mA 4 to 20 mA Control Output Unit x 2 output input E5AN HTAA2HHBFMD 500 2
23. K J T E L U VR SB W or PL II Platinum resistance thermometer Pt100 or J Pt100 Current input 4 to 20 mA or 0 to 20 mA Voltage input 1 to 5 V Oto 5 V orO to 10V Current input 150 Q max Voltage input 1 MQ min Use a 1 1 connection when connecting the ES2 HB Control method ON OFF control or 2 PID control with auto tuning Relay output Voltage output for driving SSR Output Unit Install the Output Unit sold separately Control Current output output Linear voltage output x UE E Relay output Open and close SPST NO 250 VAC 1A including in rush current electrical life 100 000 operations min pena PIER Potentiometer input Must be between 100 Q and 2 5 kQ for maximum open position Number of outputs 2 or 3 max rcd Relay output SPST NO 250 VAC 3A resistive load electrical life 100 000 operations mini licable load 5 V output Output specifications ie put NO resistive load electrical life i operations minimum applicable load 5 V Number of outputs 2 or 4 with an E53 AKB Event Contact input ON 1 kQ max OFF 100 kQ min input menal contaci input Non contact input ON Residual voltage 1 5 V max OFF Leakage current 0 1 mA max specifications Current flow Approx 7 mA per contact Number of operations 8 max e Logic operation Any of the following four patterns can be selected The input status may be inverted A and B or C and D
24. Setting Item Level ESAN ESEN only g7 25 Monitor Setting Monitor Setting H Monitor Setting g Monitor Setting H Monitor Setting IN tem Display 1 5 Item Display 2 B Item Display 3 TNN Item Display 4 Item Display 5 oo0 Li 200 o00 OOc OOd Note The monitor setting items to be displayed is set in the Monitor Setting Item 1 to 5 parameters advanced function setting level Press the O Key for at least 1 s Advanced Function Setting Level Alarm 2 Type m MC T c E L Alarm Latch He Alas B pr PF Setting B y Ni E Parameter Initialization m ILE g FI ESAN ESEN only Baa GFF EE aFF prn A M Al 2 Lx l e arm r T B Oo L Alarm 2 Latch HS Alarm Latch a PIL Monitor Setting Item 1 Hysteresis E mop M
25. Shift 1 point shift Set either Upper Limit Temperature gi these param Input Shift Value Bers 2 point shift 4 Lower Limit Temperature Input Shift Value Proportional Band Integral Time PID settings Derivative Time Cooling Coefficient Heating cooling Dead Band Display Displayed only LA once when B entering E adjustment level 3 HOP B al l mm 5 B HL AT Execute co Cancel d Ez aFF B E L NG ce 0 00 8 LMWE SAPE UISAON co 8 riting Eh off cu igi EG ag B FdA Infrared co E Communications Bee aFF Use 5 ce an a amp PMg SP Mode Bn PSP D l zz AD B FOP Fixed SP co e DD L l 30 8 h Heater Current 1 co B Value Monitor Ex ad d l ee og 8 Hhl Heater Burnout co E nn Detection 1 le B aL Heater S 544 Overcurrent Es 50 Detection 1 IL co tg Heater Current 2 Value Monitor Manual Reset Value Clear the offset during stabilization of P or PD Heater Burnout control g Detection 2 Hysteresis Heating
26. TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON S PRODUCT IS PROP ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM Programmable Products Omron Companies shall not be responsible for the user s programming of a programmable Product or any consequence thereof Performance Data Data presented in Omron Company websites catalogs and other materials is provided as a guide for the user in determining suitabil ity and does not constitute a warranty It may represent the result of Omron s test conditions and the user must correlate it to actual application require ments Actual performance is subject to the Omron s Warranty and Limitations of Liability Change in Specifications Product specifications and accessories may be changed at any time based on improvements and other reasons It is our prac tice to change part numbers when published ratings or features are changed or when significant construction changes are made However some specifica tions of the Product may be changed without any notice When in doubt spe cial part numbers may be assigned to fix or establish key specifications for your application Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product Errors and Omissions Information presented by Omron Companies has been checked and is
27. The E5CN E5CN H E5AN E5AN H E5EN and E5EN H comply with installation category ENV1 and ENV2 of Lloyd s standards Therefore they must be installed in a location equipped with air conditioning They must therefore be installed in a location equipped with air conditioning They cannot be used on the bridge or decks or in a location subject to strong vibration 2 Wiring Conditions Install the recommended ferrite core and wrap the line around itthree turns for the applicable lines e g power supply cable line and signal lines of the models listed in the following table See illustrations Install the ferrite cores as close to the terminal block of the E5L IN as possible As a guideline the ferrite core should be within 10 cm of the terminal block 0 Lines Requiring Ferrite Cores Recommended Ferrite Core Signal and power lines Manufacturer Seiwa Electric Mfg Co Ltd Model provided with ferrite cores Model E04RA310190100 E5CN E5CN U or ESCN H Input power supply Input power supply and 1 0 lines control outputs 1 and 2 communications event inputs 1 to 4 transfer output and external power supply Advanced Type models do not have an external power supply Ferrite Core Connection Examples E5CN E5CN H E5EN E5AN E5EN H or E5AN H Auxiliary outputs relay outputs r TUM Control output 1 Auxiliary output 2 Pas we ollie Auxiliary output 1 DONOT DONOT A r USE US
28. at the same time to implement the PF Key When an error occurs the No 1 display shows the error code Take necessary measure according to the error code referring the table below Status at error No 1 display Action Control output Alarm output rrun S Err Input error Check the setting of the input type Also check the input wiring and check for broken wires OFF Operates as above p vnm x or short circuits in the temperature sensor the upper limit M A D Turn the power OFF then back ON again If the display remains the same the controller must Lt 4d 4 4 E333 converter be repaired If the display is restored to normal then a probable cause can be external noise OFF OFF error affecting the control system Check for external noise _ Memor Turn the power OFF then back ON again If the display remains the same the controller must Lt f h f E111 eot y be repaired If the display is restored to normal then a probable cause can be external noise OFF OFF affecting the control system Check for external noise Note If the input value exceeds the display limit 19999 to 32400 though it is within the control range will be displayed under 19999 and above 32400 Under these conditions control output and alarm output will operate normally For details on the control range refer to the ESCN HT E5AN HT E5EN HT Digital Controllers User s Manual Programmable Type Cat No H169 Errors are shown only when the display is PV PV SV
29. believed to be accurate however no responsibility is assumed for clerical typographical or proofreading errors or omissions OMRON ELECTRONICS LLC THE AMERICAS HEADQUARTERS Schaumburg IL USA 847 843 7900 800 556 6766 www omron247 com OMRON CANADA INC HEAD OFFICE OMRON ARGENTINA SALES OFFICE Toronto ON Canada 416 286 6465 866 986 6766 Cono Sur 54 11 4783 5300 www omron247 com OMRON ELETRONICA DO BRASIL LTDA HEAD OFFICE OMRON CHILE SALES OFFICE Sao Paulo SP Brasil e 55 11 2101 6300 www omron com br Santiago e 56 9 9917 3920 OMRON ELECTRONICS MEXICO SA DE CV HEAD OFFICE OTHER OMRON LATIN AMERICA SALES Apodaca N L e 52 811 156 99 10 001 800 556 6766 mela omron com 54 11 4783 5300 OMRON EUROPE B V Wegalaan 67 69 NL 2132 JD Hoofddorp The Netherlands Tel 31 0 23 568 13 00 Fax 31 0 23 568 13 88 www industrial omron eu CSM E5AN HT ES5EN HT DS E 1 1 12 10 Note Specifications are subject to change 2010 Omron Electronics LLC
30. exceed the individual price of the Product on which liability is asserted Indemnities Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities losses claims costs and expenses including attorney s fees and expenses related to any claim inves tigation litigation or proceeding whether or not Omron is a party which arises or is alleged to arise from Buyer s acts or omissions under these Terms or in any way with respect to the Products Without limiting the foregoing Buyer at its own expense shall indemnify and hold harmless Omron and defend or set tle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party Property Confidentiality Any intellectual property in the Products is the exclu sive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron Notwithstanding any charges to Buyer for engineering or tooling all engineering and tooling shall remain the exclusive property of Omron All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party Export Controls Buyer shall comply with all applicable laws regula
31. number P V S V MV or PV SV Remaining segment time Number of digits 5 for PV and SV 4 for MV Other functions Manual output heating cooling control loop burnout alarm other alarm functions heater burnout detection including SSR failure and heater overcurrent detection 4096 AT 10096 AT MV limiter input digital filter temperature input shift run reset protection functions control output ON OFF counter extraction of square root MV change rate limit PV SV status display automatic cooling coefficient adjustment program control functions etc Ambient operating temperature 10 to 55 C with no condensation or icing for 3 year warranty 10 to 50 C Ambient operating humidity Storage temperature 2596 to 8596 25 to 65 C with no condensation or icing OMRON E5AN HT ESEN HT Input Ranges Thermocouple Platinum Resistance Thermometer Analog Input Fully Universal Inputs Platinum resistance thermometer Thermocouple Analog input 1700 01700 0 Usable in the following q ranges by scaling 19999 to 32400 1999 9 to 3240 0 199 99 to 324 00 or 19 999 to 32 400 fo 2000 a000 Eg EE 0 0 o 0 j 50 00 100 0 200 0 199 9 200 01 199 9 200 0 Shaded settings are the default settings The applicable standards for the input types are as follows o o eb o c
32. o IL ce E L AT Execute Cancel Fidi TA seu of these 3 M PID control only AL IH Alarm Value _4_11 Temperature Unit Baa OFF s88 0 0 Input Shift Value parameters Es Added when ao p Upper Limit 1 I B d L Gs i i o oe r Co co 2 point shift 4 ipa i co aoma E To i E EZS For input type of mee EL E i D temperature g LMWER ae BN SL cea for at E M GP Mutti SP E EL 1L Alarm Value E j m Em GFF ae Bea LA Input Shift Value least 3 s Cre n Set Point Setting Dre Bn Lower Limit 1 FHL HERES 4 co i E He 1300 E YE ot Ix i D cel Limit the set point a LL Heater Current 1 E HH Proportional Band t E E _ M Set Point During 570 Alarm Value 2 E a gg Value Monitor E S P Ramp 5 ML C LL E ot cr _1 SP Lower Limit ten LILI B A ae D Om n g a JL L 200 uu AER U m C30 Inn co T ooo CHU co co 9 5 HL 1 Heater Burnout E Integral Time Ss F ot J Yee 5 MA I Detection 1 B L E E LE i Heater Current 1 Value E HL cH Alarm Value E g FNL PID ON OFF Aas DD HBG 233 oo pp moniter Se 4 Upper Limit 2 5 S LNEL Era Li T o Wages Va ya PID settings jz I E B aNaF n o H aL Heater Overcurrent B d Derivative Time E ree Heater Current 2 Value Bt Bi pl Alarm Value o iz fos cgp Detection 1 D s e S LL Monitor g IL PL Lower Limit 2 E 3 C HI Standard or Bea auu BER HL E HO BELI H Heating Cooling 42 2 r rr Gooling Coefficient D J 3 oe n M E LER Leakage Current 1 T HL Jj Memwdwes 3 WS a
33. r 0000 n r oe FF u ol Di E I E Aon ii OO rit ooo unt E e zl Be b5E bh ca Ecos icf xoi 12 al o p ca zn BH nana oF co on uw zg Fr EA HH nana oP 3 A 00 m zt Fr lt gg ag co oo A goon r r1 Ej IE E3 Oo rt 4j ml MT INI m cen nn ooo LILLI co m Bg rri d ia omy oon peo O L Parameter Initialization SP Ramp Time Unit Standby Sequence Reset Auxiliary Output 1 Open in Alarm Auxiliary Output 2 Open in Alarm Auxiliary Output 3 Open in Alarm HB ON OFF Heater Burnout Latch Heater Burnout Hysteresis ST Stable Range AT Calculated Gain AT Hysteresis Limit Cycle MV Amplitude Input Digital Filter Additional PV Display Initial Setting Level Advanced Function Setting Level Key for at least 1 s Level Communica 4 tions Setting 6 e ee ceo Advanced Function Setting Level I n dP MV Displ
34. to see if input shift has been set correctly Waterproofing The degree of protection is as shown below Sections without any specification on their degree of protection or those with IPL 10 are not waterproof Front panel IP 66 Rear case IP 20 Terminal section IP 00 E5CN U Front panel IP 50 rear case IP 20 terminals IP 00 Operating Precautions 1 Ittakes approximately two seconds for the outputs to turn ON from after the power supply is turned ON Due consideration must be given to this time when incorporating Temperature Controllers in a sequence circuit 2 When using self tuning turn ON power for the load e g heater at the same time as or before supplying power to the Temperature Controller If power is turned ON for the Temperature Controller before turning ON power for the load self tuning will not be performed properly and optimum control will not be achieved 3 When starting operation after the Temperature Controller has warmed up turn OFF the power and then turn it ON again atthe same time as turning ON power for the load Instead of turning the Temperature Controller OFF and ON again switching from STOP mode to RUN mode can also be used 4 Avoid using the Controller in places near a radio television set or wireless installing These devices can cause radio disturbances which adversely affect the performance of the Controller Others 1 The diskthatis included with the Conversion Cable is designed
35. u N Alarm 1 ON Delay Assignment k H ae Eindin OOA or F Event Input Assignment 2 sm crop NN ST Stable Range Alarm 2 ON Delay g CIIL 3 Auxiliary Output 3 g 0 CL SV Status Display E B ppm Assignment E AF JL Function E OF Extraction of Square EEs HL 113 ESAN ESEN only cn FF EF Root Enable i le mI Character Select 2 AOC Ci Display Refresh co AJAN Alarm 3 ON Delay B GJ ET E Bg HMay Move to Advanced HS MeS S JH ILI Function Setting Level BE j Displayed when initial S setting communications Li CO protect is set to 0 Alarm 1 OFF Delay Soak Time Unit g RH IM Control Output 1 za m ON OFF Count Move by setting password 169 EE H Monitor ve Alarm SP Selection E m Control Output 2 Alarm 2 OFF Delay B ric H ON OFF Count ES L Monitor Control Output 1 ON OFF Count Alarm Set Value Alarm 3 OFF Delay M L1 11 Manual MV Li Li 3 PHIUNL Limit Enable Lr Lr Control Output 2 Input Shift Type z oy op PV Rate of Change ON OFF Count oI Calculation Period Alarm Set Value ye oo
36. 1 e 100 to 240 VAC 2 DO NOT USE 02 SDA 2 A Q2 UA VACN DC nopla NNNM L ra m X om wu a Mu e e e e e e c0 8 ei i Event Inputs Input power suppl pply EV P otentiometer Auxiliary output 3 e Auxiliary output 3 p eis output SPDT 250 VAC 3A resistive load Control output 1 Control output 2 B DO NOT DO NOT DO NOT o oo00020 huxiliary output 2 aoe vee USE A heater burnout alarm SSR DONOT 4 DO NOT y T failure heater overcurrent USE USE E alarm input alarm or Remote B SP Input Error is sent to the T m output to which the alarm 1 MP i B DO NOT DO NOT function is assigned USE USE EV3 and EVA are assigned to event inputs in controllers with two event inputs E vent input Transfer output Remote SP Models with Position Control Output Unit proportional Control Control outputs 1 2 Input power o Control Output Unit SUppty LQ Control outputs 1 2 B Refer to page 4 Models with Position proportional Control Relay output 250 VAC 1A Input power supply L 2 RURAL r including inrush current 7 4 to 20 mA DC Auxiliary output 2 Transfer output L Load 600 Q max Auxiliary output 2 Relay output SPST NO 250 VAC 3A resistive load Auxiliary output 1 Auxiliary output 1 Re
37. 4 VAC 4 to 20 mA 4 to 20 mA VDC Control Output Unit x 2 output input E5AN HTAA3BFMD 500 Relay outputs x 2 nu E5AN HTPRR2BMD 500 4 to 20 mA 4 to 20 mA Relay outputs x 2 output input E5AN HTPRR2BFMD 500 Power supply voltage 100 to 240 VAC Black 24 VACIVDC Control method Control output 1 2 Control Output Unit x 2 Control Output Unit x 2 Heater burn out Optional Functions Control Output Unit x 2 Relay outputs x 2 Relay outputs x 2 Control Output Unit x 2 Control Output Unit x 2 Control Output Unit x 2 Relay outputs x 2 Relay outputs x 2 Transfer Model output 4 to 20 MA E amp EN HTAA2HBM 500 Input 4 to 20 mA 4 to 20 mA EsEN HITAA2HHBFM 500 output Input 4 to 20 mA 4 to 20 MA EcEN HTAASBEM 500 output Input 4 to 20 mA nu E5EN HTPRR2BM 500 4 to 20 mA 4 to 20 MA E5EN HTPRR2BFM 500 output Input 4 to 20 MA E amp EN HTAA2HBMD 500 Input 4 to 20 mA 4 to 20 mA ESEN HTAA2HHBFMD output input 500 4 to 20 mA 4 to 20 mA ipn ou E5EN HTAA3BFMD 500 4 to 20 MA E amp EN HTPRR2BMD 500 Input 4 to 20 mA 4 to 20 mA dm em E5EN HTPRR2BFMD 500 OMRON Accessories Order Separately Output unit Model Specifications Relay E53 RN SPST NO 250 VAC 5A resistive load output electrical life 100 000 operations E53 QN 12 VDC PNP max load current Voltage 40 mA with short circuit protection output E53 03 24 VDC N
38. A or C and B or D Aor B or C or D A and B and C and D Operations A B C and D are four inputs p e Delay ON delay or OFF delay for the results of the logic operation given above Logic Setting time 0 to 9999 s or 0 to 9999 min operations e Output inversion Possible Output One work bit per operation Work bit Any of The following can be assigned to up to eight work bits logic operation results operation commands assigned to event ET inputs auxiliary outputs or control outputs g Application is possible with models that do not have event inputs by using an internal assignment Transfer Number of outputs 1 max Depends on model Models with transfer output F in model number outputs Output specifications Current output 4 to 20 mA DC Load 600 Q max Resolution at 4 to 20 mA Approx 10 000 Number of inputs 1 Signal type Current input 4 to 20 mA input impedance 150 Q 10 RSP Andlonmuputscam Scaling of signal to engineering units EU input g inp 9 19 999 to 30 000 display 30 000 max Accuracy Input sampling period 60 ms Setting method Indication method 40 296 of FS 1 digit max S et digitally using keys on the front panel or by using the RSP input 11 segment digital display and individual indicators 7 segments displays also possible Character height E5AN HT PV 15 8 mm SV 9 5 mm MV 6 8 mm E5EN HT PV 11 8 mm SV 8 1 mm MV 5 8 mm Three displays P V SV P rogram number S egment
39. E ats i Power supply y Input power I DO NOT Ly 1 Puoi 3 turns USE E Analog input i TC Pt universal input E5AN E5EN E5AN H E5EN H e 3 turns eed Input power Connected to supply SUE communications or EV1 3 turns event inputs 1 and 2 Control External Power CT1 CT2 Output2 Supply 3 turns _ E DM CTI Control External power supply Connected to de Output2 12 VDC 20 mA gt control output 2 Connected to control output 1 _ 3 turns or external Auxiliary output 3 DO NOT DO NOT USE USE Auxiliary output 2 A DO NOT B lt huxiliary output 1 B V DO NOT n USE Y TC Ptuniversal input Analog input 61 I Communications l RS 232C RS 485 l Q2 sp 1 B Q3 2 RD 2 A i Connected to event qa D 3 sG 3 Do NOTUSE psu 3 turns Do Nor USE amp 2 8 e 62 Do NOT USE Q2 A l DO NOT USE O E E Je eee E J Connected to 4 to 20 mA DC Transfer output transfer output 3 turns ranster output eo Load 600 Q max DO NOT USE DO NOT USE OMRON Safety Precautions for E5 IN E5 IN H E5 IN HT Precautions for Correct Use Service Life 1 Use the product within the following temperature and humidity ranges Temperature 10 to 55 C with no icing or condensation Humidity 2596 to 8596 If the productis installed inside a control board the ambient temperature must be kept to under 55 C
40. HT E5EN HT Digital Controllers User s Manual Cat No H169 for information on the loop burnout alarm LBA 9 Refer to the ESCN HT E5AN HT E5EN HT Digital Controllers User s Manual Cat No H169 for information on the PV change rate alarm OMRON E5AN HT ESEN HT Characteristics Thermocouple 0 1 of indicated value or 1 C whichever is greater 1 digit max 1 Platinum resistance thermometer 0 1 of indicated value or 0 5 C whichever is greater 1 digit max Indication accuracy Analog input 0 1 FS 1 digit max CT input 5 FS 1 digit max Potentiometer input 5 FS 1 digit max Transfer output accuracy 0 3 FS max Influence of temperature Thermocouple input R S B W PL II 1 of PV or 410 C whichever is greater 1 digit max X2 Other thermocouple input 1 of PV or 4 C whichever is greater 1 digit max 3 Platinum resistance thermometer 1 of PV or 2 C whichever is greater 1 digit max Influence of voltage 2 Analog input 196FS 1 digit max Input sampling period 60 ms Temperature input 0 1 to 3240 0 C or F in units of 0 1 C or F Analog input 0 0196 to 99 9996 FS in units of 0 0196 FS Temperature input 0 1 to 3240 0 C or F in units of 0 1 C or F Analog input 0 196 to 999 996 FS in units of 0 196 FS Hysteresis Proportional band P Integral time I 0 0 to 3240 0 s in units of 0 1 s Derivative time D 0
41. N Output Unit is used for control output 1 or 2 For these combinations maintain the following mounting space between Controllers 60 min gt pues 120 min OMRON E5AN HT ESEN HT Accessories Order Separately USB Infrared Conversion Cable E58 CIFIR USB Infrared Conversion Cable 2 000 T 54 NA USB connector type A plug LED indicator RD LED indicator SD Mounting Adapter Mounting Adapter Accessory USB Serial Conversion Cable E58 CIFQ1 2 100 250 mE LED indicator SD lt lt 1 765 kl TE Hill E USB connector type A plug Serial connector LED indicator RD Terminal Covers E53 COV16 Six Covers provided 12 32 OMRON Waterproof Packing Y92S P4 for DIN 96 x 96 Y92S P5 for DIN 48 x 96 N E5AN HT E5EN HT Order the Waterproof Packing separately if it becomes lost or damaged The Waterproof P acking can be used to achieve an IP66 degree of protection Deterioration shrinking or hardening of the waterproof packing may occur depending on the operating environment Therefore periodic replacement is recommended to ensure the level of waterproofing specified in IP66 The time for periodic replacement depends on the operating environment Be sure to confirm this point at your site Consider one year a rough standard OMRON shall not be liable for the level of water resistance if the cust
42. PN max load current for driving 20 mA with short circuit protection SSR E53 04 24 VDC PNP max load current 20 mA with short circuit protection 4 to 20 mA DC load 600 Q max Current E53 C3N resolution approx 10 000 output 0 to 20 mA DC load 600 Q max E53 C3DN resolution approx 10 000 naar E53 V34N 0 to 10 VDC load 1 kO min resolution approx 10 000 voltage 0 to 5 VDC load 1 KQ min resolution output 000 p E53 V35N approx 10 000 USB infrared Conversion Cable Model E58 CIFIR USB Serial Conversion Cable Model E58 CIFQ1 Terminal Cover Connectable models Model E5AN HT E53 COV16 E5EN HT Note The Terminal Cover comes with the E5AN E5EN LILILI 500 models Waterproof Packing Connectable models Model E5AN HT Y92S P4 E5EN HT Y92S P5 Note The Waterproof Packing is included with the Controller Current Transformers CTs Hole diameter Model 5 8 dia E54 CT1 12 0 dia E54 CT3 CX Thermo Support Software Model EST2 2C MV4 ESAN HT ESEN HT OMRON Specifications Ratings Power supply voltage E5AN HT ESEN HT No D in model number 100 to 240 VAC 50 60 Hz D in model number 24 VAC 50 60 Hz 24 VDC Operating voltage range Power consumption 8596 to 11096 of rated supply voltage 100 to 240 VAC 12 VA 24 VACNDC 8 5 VA 24 VAC 5 5 W 24 VDC Sensor input Input impedance Any of the following can be selected Thermocouple
43. Programmable Temperature Controller Digital Controller ESAN HT ESEN HT 96 x 96 mm and 48 x 96 mm CSM_E5AN HT_E5EN HT_DS_E_1_1 Programmable Controllers Join the Series Program up to 256 segments and take advantage of the excellent cost performance of the new LCD that improves both the field of view and contrast e Set up to 8 programmed patterns with up to 32 segments steps each e High resolution display with 5 digits 0 01 C display e High speed sampling cycle of 60 ms e High Accuracy Thermocouple Pt input 0 1 of PV Analog input 0 1 FS e Universal inputs on all models thermocouple PT or analog input to handle various sensors with one Controller Models also available with Remote SP e A PV SV status display function can be set to automatically alternate between displaying the status of the Temperature Controller auto manual RUN RESET and alarms and the PV or 96 x 96 mm 48 x 96 mm SV E5AN HT E5EN HT e Flexible contact outputs with logic operations AND OR and delays set from the Support Software CX Thermo version 4 3 N D d Precautions for ESL IN ESLIN H Program settings can be managed An infrared ports enables communications from the front panel Preventive maintenance for relays in the Temperature Controller using a Control Output ON OFF Counter Model available with position proportional control Refer to Operation for E5 IN E5 IN H E5 JN HT for operating proced
44. Se eb pus Se eb Q S E Setting number K J T E NR S B JIS C 1602 1995 IEC 584 1 J Pt100 JIS C 1604 1989 JIS C 1606 1989 L Fe CuNi DIN 43710 1985 Pt100 JIS C 1604 1997 IEC 751 U Cu CuNi DIN 43710 1985 PL Il According to Platinel Il electromotive force charts from BASF previously W W5Re W26Re ASTM E988 1990 Engelhard OMRON Alarm Outputs E5AN HT ESEN HT Each alarm can be independently set to one of the following 15 alarm types The default is 2 Upper limit Auxiliary outputs are allocated for alarms ON delays and OFF delays 0 to 999 s can also be specified Note For models with heater burnout SSR failure and heater overcurrent detection alarm 1 will be an OR output of the alarm selected from the following alarm types and the alarms for heater burnout SSR failure and heater overcurrent To output only a heater burnout alarm SSR failure alarm and heater overcurrent alarm for alarm 1 set the alarm type to 0 i e no alarm function Alarm output operation Set value Alarm type When alarm value When alarm value Description of function X is positive X is negative 0 Alarm function OFF Output OFF No alarm dimi ON ES Setthe deviation in the set point by setting the alarm 1 Upper and lower limit 1 OFF mu im upper limit H and alarm lower limit L Ee ON
45. Xe Set the upward deviation in the set point by setting Upper limit Ort i m the alarm value X hai ON i ins S etthe downward deviation in the set point by setting 3 Lower limit OFF gU the alarm value X Tieni ON Le Setthe deviation in the set point by setting the alarm PPPS ama PWETAN E UPE EN upper limit H and alarm lower limit L 5 Upper and lower limit with d mmm A standby sequence is added to the upper and standby sequence 1 ur SP lower limit alarm 1 7 X X zem 6 Upper limit with standby sequence on mw DE sequence is added to the upper limitalarm SP SP X X Jiri J a E Sequence V gt oN a E sequence is added to the lower limit alarm SP SP Te ON rout ON The alarm will turn ON if the process value is larger g Absolute value upper limit Ore _ OEE io than the alarm value X regardless of the set point ee ON ON a The alarm will turn ON if the process value is smaller AOS OUTE VALUE ower limit OFF Exi m than the alarm value X regardless of the set point Absolute value upper limit with ON X A standby sequence is added to the absolute value zi standby sequence luin upper limit alarm 8 7 Absolute value lower limit with maa A standby sequence is added to the absolute value H standby sequence m lower limit alarm 9 7 12 LBA alarm 1 type only KO 13 x9 The alarm turns ON when the remote SP RSP is 14 RSP absolute value upper limit 6 larger t
46. ally designed for indoor use only Do not use this product in the following places e Places directly subject to heat radiated from heating equipment Places subject to splashing liquid or oil atmosphere Places subject to direct sunlight Places subject to dust or corrosive gas in particular sulfide gas and ammonia gas Places subject to intense temperature change Places subjectto icing and condensation Places subject to vibration and large shocks Use and store the product within the rated ambient temperature and humidity Gang mounting two or more Temperature Controllers or mounting Temperature Controllers above each other may cause heat to build up inside the Temperature Controllers which will shorten their service life In such a case use forced cooling by fans or other means of air ventilation to cool down the Temperature Controllers To allow heatto escape do notblock the area around the product Do not block the ventilation holes on the product Be sure to wire properly with correct polarity of terminals Use the specified size of crimp terminals for wiring for the E5CN E5AN or E5EN M3 5 width of 7 2 mm or less For open wired connections to the E5CN E5AN or E5EN use stranded or solid copper wires with a gauge of AWG24 to AWG14 equal to a cross sectional area of 0 205 to 2 081 mm The stripping length is 5 to 6 mm Up to two wires of the same size and type or two crimp terminals can be connected to
47. an the set value i e heater burnout detection current value 2 ForSSR failure alarms the heater current will be measured when the control output is OFF and the output assigned to the alarm 1 function will turn ON if the heater current is higher than the set value i e SSR failure detection current value 3 For heater overcurrent alarms the heater current will be measured when the control outputis ON and the outputassigned to the alarm 1 function will turn ON if the heater current is higher than the set value i e heater overcurrent detection current value Electrical Life Expectancy Curve for Relays Reference Values 0 l T l1 Tl ID x 69 e e E5AN HT E5EN HT 250 VAC 30 VDC resistive load No of operations x 1 IM O e S witching current A OMRON E5AN HT E5EN HT External Connections Control output 1 and control output 2 are functionally isolated from the internal circuits Controllers Option Units Communications The Temperature Controller is set for a K type thermocouple input type 5 by default An input error 5 ERR will occur if the input type E53 EN01 E53 EN02 E53 EN03 E53 AKB RS 232C RS 422 RS 485 setting does not agree with the 1 SD 1 RDB amp 2 B pe EV2 i ue sensor Check the RD 12 RDA T A DO EUR 3 sc 3 sG 3 DO NOT USE Ot i DO NOT USE 1 spB 01 B
48. ations Protect Communications Hysteresis This protect level restricts B hF 5 Baud Rate y movement to the initial setting communications setting and em ib CSYSNWAY ani B d i Temperature Unit advanced function setting levels y B dii Ee SIS FOFInBUEIVDSID Setting Change Protect Ez or kei Transfer Output Type Protects changes to setups B 1 EN Communications co Linear output by operating the front panel a Q4 Data Length keys zzz um y i at G H SP Upper Limit RE Ee gm uui Transfer Output ey Protect n Upper Limit Restriats PF key operation B 5 h i L Communications Limit the set point pp E5AN H E5EN H only B 7 Stop Bits s et GI I SP Lower Limit Parameter Mask Enable J ce s COG Transfer Output Displayed only when a c DOLU CAT parameter mask is set gee oian co Em EVEN rw rere 8 NE PID ON OFF B LNLL Password to Move to J ce Em Pid Linear Current Output Protect Level D um um TE Password setting B D dl ME Send Data Wait Time co Linear output EE eu B Lit Standard or B a HE Heating Cooling ce EE SENd Bank Numbers Used J 8 GEIST Self tuning Es For input type of Ezz ow temperature Event Input standard control or Assignment 1 ee PID Program Pattern Event Input Assignment 2 Valid Program Bank When assigning PID or control output to ON OFF Event Input output Assignment 3 T E LP Control Period Heating EES eu Set the ON OFF Even
49. auxiliary output 2 on the E5GN The exposed conductor length inserted into the terminal for wires or ferrules must be 6 mm Ferrules must be 0 8 to 1 5 mm in diameter 3 mm max 0 8 to 1 5 E 6 mm 6 mm Ferrules Wires e Recommended Ferrules for SUB2 on E5GN Manufacturer Model number Al 0 25 6 BU Al 0 34 6 TQ Phoenix Contact Al 0 5 6 WH Al 0 75 6 GY Al 1 6 RD Note Do not remove the terminal block from the E5AN E5EN or E5CN Doing so may cause product malfunction or incorrect operation OMRON Terms and Conditions of Sale OMRON 5 7 10 11 12 13 Offer Acceptance These terms and conditions these Terms are deemed part of all quotes agreements purchase orders acknowledgments price lists catalogs manuals brochures and other documents whether electronic or in writing relating to the sale of products or services collectively the Products by Omron Electronics LLC and its subsidiary companies Omron Omron objects to any terms or conditions proposed in Buyer s purchase order or other documents which are inconsistent with or in addition to these Terms Prices Payment Terms All prices stated are current subject to change with out notice by Omron Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders Payments for Products are due net 30 days unless otherwise stated in the invoice Discounts Cash discounts if any will ap
50. ay rir L Automatic Display Return Time Alarm 1 Latch Alarm 2 Latch Alarm 3 Latch Move to Protect Level Time Input Error Output Cold Junction n Compensation Method MB Command Logic Switching nL FR PV Change Color PV Stable Band Alarm 1 ON Delay Alarm 2 ON Delay Alarm 3 ON Delay la F Alarm 1 OFF Delay Alarm 2 OFF Delay Alarm 3 OFF Delay e LOEF me ES NGI e S Myce B IV SE m BEES aFF co MEI 1 8 HMHd m ZIM coo om i E NE a m nFF l a NI e ASL e EES oN e HhL ea ES aFF ca i 5 LOH io EE g E LhAL e EE aul aI 2a Er L1 e Emm id 4J l Di 7 rn nu Di zz ra IT 4j 0000 t L1 cz EG I x 4 Input Shift Type MV at Stop and Error Addition Auto Manual Select Addition RT HS Alarm Use HS Alarm Latch HS Alarm Hysteresis LBA Detection Time LBA Level LBA Band Control Output 1 Assignment Control Output 2 Assignment Auxiliary Output 1 Assignment Auxiliary Output 2 Assignment Auxiliary Output 3 Assignment E5AN E5EN H only Character Select Soak Time Unit
51. dition to other remedies cancel any unshipped portion of Prod ucts sold hereunder and stop any Products in transit until Buyer pays all amounts including amounts payable hereunder whether or not then due which are owing to it by Buyer Buyer shall in any event remain liable for all unpaid accounts Cancellation Etc Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses Force Majeure Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control including earthquakes fires floods strikes or other labor disputes shortage of labor or materials accidents to machinery acts of sabotage riots delay in or lack of transportation or the requirements of any government authority Shipping Delivery Unless otherwise expressly agreed in writing by Omron a Shipments shall be by a carrier selected by Omron Omron will not drop ship except in break down situations b Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer c All sales and shipments of Products shall be FOB shipping point unless oth erwise stated in writing by Omron at which point title and risk of loss shall pass from Omron to Buyer provided that Omron shall retain a security inter est in the Products until the full purchase price is paid d Delivery and shipping dates are estimates only and e Omron
52. e and press the E5SAN E5EN toward the rear case until itsnaps into position While pressing the E5AN E5EN into place press down on the hooks on the top and bottom surfaces ofthe rear case so thatthe hooks securely lock in place Make sure that electronic components do not come into contact with the case Removing the Terminal Block The terminal block can be removed from the E5GN It is not possible for the E5CN E5AN E5EN and E5CN U E5GN The body of the Controller can be replaced by removing the terminal block from the E5GN 1 Insert a flat blade screwdriver into the tool holes one on the top and one on the bottom to release the hooks Do not apply excessive force Flat blade screwdriver Unit mm Note The method for removing the terminal block is the same for both screw terminal blocks and screwless clamp terminal blocks Do notconnecta different type of terminal block to a Controller For example do not replace a screw terminal block with a screwless clamp terminal block The temperature indication accuracy will decrease Tool insertion Precautions when Wiring e Separate input leads and power lines in order to prevent external noise Use a shielded AWG24 to AWG 14 cross sectional area of 0 205 to 2 081 mm twisted pair cable for the E5CN E5EN or E5AN Use a shielded AWG24 to AWG18 cross sectional area of 0 205 to 0 823 mm twisted pair cable forthe E5GN The stripping length is 5 to 6 mm for
53. en Additional RUN STOP p EE PV display is ON Em RUN B 5 Proportional Band ooo B co co Ga co MAYA i s g 25 0 Process Value g HL i Alarm Value 1 2 B L Integral Time Em Set Point EE t S En 2330 es I ES a wn E o l ce PID settings B H M Auto Manual Switch BH amp PID control only g ML I Alarm Value 5 E Ci rao Press E Added when Er D n Upper Limit 1 5 Ls n n Derivative Time auto manual select 4 ED eni the O CQ addition is ON co Key for SE C 2 Bank No E HL IL Alarm Value E Gooling Coefficient E o ESS Lag ce eo Heating cooling i 2 SS Remote SP Monitor et Al 2 D e f dh E Alarm Value 2 lt 4 EM 4 Dead Band Em ad g ooo LILI S ES ec m 3 E of Manual Reset Value Set Point Durin 8 ALCH Alarm Value 3 H nr n g Bg H Clear the offset during SP Ramp ez n n Upper Limit 2 Press the O c GB stabilization of P or PD no control co and Ice Keys for co s at least 1 s Ec EH gl o Bx HYG Heater Current 1 Value B FILL Alarm Value Ces IB Hysteresis Heating Monitor Cr mg Lower Limit 2 Co Hysteresis settings co g us m o Se HYS Heater Current 2 Value E AL 3 Alarm Value 3 E E iB Hysteresis Cooling Monitor Ec an S o Je 2 ec Dm J SaR Soak Time Leakage Current 1 oe JH alarm Value 2 E Monitor B nn Upperlimit3 5 oO l Ee ex p a or PL ct g E Wait Band Leakage C
54. en a probable cause can be external noise OFF OFF affecting the control system Check for external noise Note If the input value exceeds the display limit 19999 to 32400 though it is within the control range will be displayed under 19999 and above 32400 Under these conditions control output and alarm output will operate normally For details on the control range refer to the ESCN H E5AN H E5EN H Digital Controllers User s Manual Advanced Type Cat No H157 Errors are shown only when the display is PV PV SV or PV MV Errors are not shown for any other status OMRON Operation for E5 N E5 N H E5 IN HT Programmable Type E5CN HT E5AN HT E5EN HT Power ON Start in automatic mode Start in manual mode Press the O Key or the PF Key for at least 1 s 4 Level gt Press the v O Key less than 1 Press the Of Key less than 1 s ri rt EB Press the O Key for at least 3 s while A M is displayed M I 00000 PID Setting A will flash after Manual lst second Level B mode x3 ress the O Key less than 1 s Press the O Program z ce Keys for at Setting Level eo espe 9 the O S Press the E Pede z oo li dpi less least 3 sjaa idan will flash after 1st Adjustment second Level Press the PF Key
55. ers PAW oF NU ae Do not touch the terminals while power is being Supplied Doing so may occasionally result in minor injury due to electric shock Do not allow pieces of metal wire clippings or fine metallic shavings or filings from installation to enter the product Doing so may occasionally result in electric shock fire or malfunction Do not use the product where subject to flammable or explosive gas Otherwise minor injury from explosion may occasionally occur Do not leave the cable for the Support Software connected to the product Malfunction may occur due to noise in the cable Do not use the Temperature Controller or Conversion Cable if itis damaged Doing so may occasionally result in minor electric shock or fire Never disassemble modify or repair the product or touch any of the internal parts Minor electric shock fire or malfunction may occasionally occur CAUTION Risk of Fire and Electric Shock a This product is UL listed as Open Type Process Control Equipment It must be mounted in an enclosure that does not allow fire to escape externally b More than one disconnect switch may be required to de energize the equipment before servicing the product C Signal inputs are SELV limited energy 1 d Caution To reduce the risk of fire or electric shock do not interconnect the outputs of different Class 2 circuits 2 If the output relays are used past their life expectancy contact fusing o
56. ess the O Key less than 1 s E ZM L Protect Level Communications B N e Setting Level ASI pS The time taken to move to the protect level a A can be adjusted by changing ihe Move to Displayed only for i nds with Pup Lc edd Changes I ce ime setti are effective after cycling power or after a software reset protect level time setting yciing p ET wy pan c Move to Protect Level B Em Un Alarm 2 Displayed only when a password G cc Protocol Setting Hysteresis is set Restricts moving to protect H J 5E L Switches between level Es re CompoWay F SYSWAY y and Modbus 8 N L Scaling Lower Limit Qi run tat o Alarm 3 Type L s dh AE I C Restricts displaying and o 21 MZ Communications Unit No modifying menus in B una operation adjustment and EE i E TE Decimal Poi manual control levels S di ecimal Point Initial Setting ce SEES fil For input type of analog Alarm 3 Communic
57. for a computer CD ROM driver Never attempt to play the disk in a general purpose audio player 2 Do not connect or disconnect the Conversion Cable connector repeatedly over a short period of time The computer may malfunction 3 After connecting the Conversion Cable to the computer check the COM port number before starting communications The computer requires time to recognize the cable connection This delay does not indicate failure 4 Do not connect the Conversion Cable through a USB hub Doing so may damage the Conversion Cable 5 Do not use an extension cable to extend the Conversion Cable length when connecting to the computer Doing so may damage the Conversion Cable 6 The E5AN H E5EN H use the same port for communications through the infrared port and the Support Software port Do not attempt to use communications through the Support S oftware port when the infrared port is being used Mounting Mounting to a Panel For waterproof mounting waterproof packing must be installed on the Controller Waterproofing is not possible when group mounting several Controllers Waterproof packing is not necessary when there is no need for the waterproofing function E5CN Order the P 2CF 11 or P3GA 11 Socket separately E53 COV17 Terminal Cover Accessory Adapter Accessory iq DAB E5CN U d R k t For Front mounting Socke Waterproof packing dier necessary TA E5CN Panel mounting is a
58. han the alarm value X This alarm functions in both Local SP and Remote SP Modes The alarm turns ON when the remote SP RSP is 15 RSP absolute value lower limit 6 smaller than the alarm value X This alarm functions in both Local SP and Remote SP Modes 1 With set values 1 4 and 5 the upper and lower limit values can be set independently for each alarm type and are expressed as und and H 2 Set value 1 Upper and lower limit alarm Case 1 Case 2 Case 3 Always ON p H lt 0 L lt 0 L H SP SPL H H SP L H 0 L 0 H 0 L 0 EBENEN H lt 0 L gt 0 IH ILI IH gt ILI H LSP JH gt LI H gt 0 L lt 0 SPH L IH Iul 3 Set value 4 U pper and lower limit range Case 1 Case 2 Case 3 Always ON H 0 L 0 L H SP SPL H H SP L H lt 0 L H lt 0 L gt 0 H gt 0 L lt 0 s A it IH lt L IH gt L H LSP H 0 L 0 spu L IAI SILI 4 S et value 5 Upper and lower limit with standby sequence For Upper and Lower Limit Alarm Described Above Case land 2 Always OFF when the upper limit and lower limit hysteresis overlaps Case 3 Always OFF 5 Set value 5 Upper and lower limit with standby sequence Always OFF when the upper limit and lower limit hysteresis overlaps 6 Displayed when there is a remote SP input 7 Refer to the ESCN HT E5AN HT E5EN HT Digital Controllers User s Manual Cat No H169 for information on the operation of the standby sequence 8 Refer to the ESCN HT E5AN
59. including the temperature around the product 2 The service life of electronic devices like Temperature Controllers is determined notonly by the number of times the relay is switched but also by the service life of internal electronic components Componentservice life is affected by the ambienttemperature the higher the temperature the shorter the service life and the lower the temperature the longer the service life Therefore the service life can be extended by lowering the temperature of the Temperature Controller 3 When two or more Temperature Controllers are mounted horizontally close to each other or vertically next to one another the internal temperature will increase due to heat radiated by the Temperature Controllers and the service life will decrease In such a case use forced cooling by fans or other means of air ventilation to cool down the Temperature Controllers When providing forced cooling however be careful not to cool down the terminals sections alone to avoid measurement errors Measurement Accuracy 1 When extending or connecting the thermocouple lead wire be sure to use compensating wires that match the thermocouple types 2 When extending or connecting the lead wire of the platinum resistance thermometer be sure to use wires that have low resistance and keep the resistance of the three lead wires the same 3 Mount the product so that it is horizontally level 4 If the measurement accuracy is low check
60. ing Item 3 Assignment E5AN E5EN HT only cz oc L DD 0000 TRS m Auxiliary Output 2 Alarm 1 ON Delay Character Select Monitor Setting Item 4 Open in Alarm Auxiliary Output 3 Alarm 2 ON Delay Monitor Setting Item 5 Open in Alarm PV SP Display nfl Alarm 3 ON Dela Remote SP Enable EEG Hia IN y Screen Selection Heater Burnout IZ Alarm 1 OFF Delay Remote SP MV Display Selection Latch D Upper Limit Remote SP PV Decimal Point Heater Burnout Alarm 2 OFF Delay R Hysteresis Display Alarm 3 OFF Delay SP Tracking H ae Display unction i i e R P Ir V Status Display l t Shift emote SP I put S AT Calculated Gai pu l yp De E i AT Hysteresis MV at Reset and Error PlpiseaAuiomatic Display Refresh Actelion Selection Data Period imi Auto Manual Select PID Set Automatic Control Output 1 R i Addition Selection Hysteresis ON OFF Count Monitor Input Digital Filter PV Dead Band Control Output 2 ON OFF Count Monitor
61. input wiring and check for broken wires Operates as above a m9 S Err aqu OFF e or short circuits in the temperature sensor the upper limit HN A D Turn the power OFF then back ON again If the display remains the same the controller must Lt 44 4 E333 converter berepaired If the display is restored to normal then a probable cause can be external noise OFF OFF error affecting the control system Check for external noise _ T Turn the power OFF then back ON again If the display remains the same the controller must Lt f f f E111 AM y be repaired If the display is restored to normal then a probable cause can be external noise OFF OFF affecting the control system Check for external noise Note If the input value exceeds the display limit 1999 to 9999 though it is within the control range will be displayed under 1999 and above 9999 Under these conditions control output and alarm output will operate normally For details on the control range refer to the ESCN E5AN E5EN E5GN Digital Temperature Controllers User s Manual Basic Type Cat No H156 Errors are shown only when the display is PV PV SV or PV MV Errors are not shown for any other status OMRON Advanced Type E5CN H E5AN H E5EN H Start in manual mode Operation for E5 N E5 N H E5 IN HT Power ON Start in automatic mode
62. ise in particular motors transformers solenoids magnetic coils or other equipment that have an inductance component When a noise filter is used atthe power supply first check the voltage or current and attach the noise filter as close as possible to the product Allow as much space as possible between the product and devices that generate powerful high frequencies high frequency welders high frequency sewing machines etc or surge 8 Use this product within the rated load and power supply 9 Make sure thatthe rated voltage is attained within two seconds of turning ON the power using a switch or relay contact If the voltage is applied gradually the power may not be reset or output malfunctions may occur 10 Make sure that the Temperature Controller has 30 minutes or more to warm up after turning ON the power before starting actual control operations to ensure the correct temperature display 11 When executing self tuning turn ON power to the load e g heater at the same time as or before supplying power to the product If power is turned ON to the product before turning ON power to the load self tuning will not be performed properly and optimum control will not be achieved 12 A switch or circuit breaker must be provided close to the product The switch or circuit breaker must be within easy reach of the operator and must be marked as a disconnecting means for this unit 13 Always turn OFF the power supply before removi
63. lf duplex or RS 232C Synchronization Start stop synchronization method Protocol CompoWay F or Modbus Baud rate 1200 2400 4800 9600 19200 38400 or 57600 bps Transmission code ASCII CompoW ay F RTU Modbus Data bit length 7 or 8 bits Stop bit length 1 or 2 bits Error detection Vertical parity none even odd Block check character BCC with CompoW ay F or CRC 16 Modbus Flow control None Interface RS 485 RS 422 or RS 232C Retry function None Communications buffer 217 bytes Communications 0 to 99 ms response wait time The baud rate data bit be individually set usin Default 20 ms length stop bit length and vertical parity can g the Communications Setting Level Current Transformer Order Separately Ratings Dielectric strength 1 000 VAC for 1 min Vibration resistance 50 Hz 98 m s Weight E54 CT1 Approx 11 5 g E54 CT3 Approx 50 g Accessories E54 CT3 on Armatures 2 ly Plugs 2 E5AN HT ESEN HT USB Infrared Conversion Cable Applicable OS Windows 2000 XP Vista or 7 Applicable software CX Thermo version 4 0 or higher Applicable models E5AN H E5EN H E5AN HT E5EN HT USB interface standard Conforms to USB Specification 1 1 DTE speed 38400 bps Connector specifications Computer USB type A plug Temperature Controller Infrared port on front of Controller
64. lso possible 1 The Panel Mounting Adapter is also included with the E5CN U There is no waterproof packing included with the E5CN U 2 Insert the ESCN E5CN U into the mounting hole in the panel 3 Push the adapter from the terminals up to the panel and temporarily fasten the ESCN E5CN U 4 Tighten the two fastening screws on the adapter Alternately tighten the two screws little by little to maintain a balance Tighten the screws to a torque of 0 29 to 0 39 N m OMRON Safety Precautions for E5 IN E5 IN H E5 IN HT E5EN E5AN Mounting Bracket Panel Accessory E53 COV16 Terminal Cover Accessory Waterproof packing E5AN Accessory Mounting Bracket Accessory E53 COV16 Terminal Cover Accessory Waterproof packing E5EN Accessory 1 Insert the E5AN E5EN into the square mounting hole in the panel thickness 1 to 8 mm Attach the Mounting Brackets provided with the product to the mounting grooves on the top and bottom surfaces of the rear case 2 Use a ratchet to alternately tighten the screws on the top and bottom Mounting Brackets little by little to maintain balance until the ratchet turns freely E5GN Waterproof packing Insertthe E5GN into the mounting hole in the panel 2 Push the adapter from the terminals up to the panel and temporarily fasten the E5GN 3 Tighten the two fastening screws on the adapter Al
65. mote SP input I 4 to 20 mA DC 7 L po rA Note Wire all voltage input terminals correctly The Controller may fail if voltage input terminals are wired incorrectly OMRON E5AN HT ESEN HT Nomenclature E5AN HT ESEN HT Temperature unit I7 igi ivi ig i Vi M iM IV ICLALAUALIA MUU NAN T aL oy dd 1 i iT i i sv rire ey vy DC DO DO Operation indicators Programmable Mode Key Function Key Mode Key Auto M anual Key Fives Programmable Function Key Auto M anual Key d JEN Uv Dimensions Unit mm E5AN HT Mounted Separately Group Mounted 9205 pa x number of units 3 5 0 4 4 mE y Group mounting does not allow waterproofing e Recommended panel thickness is 1 to 8 mm e Group mounting is not possible in the vertical direction Maintain the specified 9202 mounting space between Controllers 6 e To mountthe Controller so that it is 120 min i waterproof insert the waterproof packing onto the Controller e When two or more Controllers are mounted make sure that the surrounding temperature does not N exceed the allowable operating HE M M M M PV Urs temperature specified in the EAIAUAUAUA Specifications Group mounting is not possible if an E53 C3N or E53 C3DN j j j j J 96 x 96 sal a 91 Output Unit is u
66. nformity with any standards codes or regulations which apply to the combination of the Product in the Buyers application or use of the Product At Buyer s request Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product This information by itself is not sufficient for a complete determination of the suitability of the Prod uct in combination with the end product machine system or other application or use Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application product or system Buyer shall take application responsibility in all cases but the following is a non exhaustive list of applications for which particular attention must be given i Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document ii Use in consumer products or any use in significant quantities iii Energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equip ment and installations subject to separate industry or government regulations iv Systems machines and equipment that could present a risk to life or prop erty Please know and observe all prohibitions of use applicable to this Prod uct NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK
67. ng Level Press the O Key less than 1 s Press the O Key less than 1 s co a UIP Es 80 ch P PID 8 Proportional Band gm BD I ca Bank 7 SP E La A Bank 7 c 2330 g E PID 8 Integral Time Alarm Value 2 ca Em 2330 l Bank 7 PID Mainz n Set No Bank 7 Alarm Value Upper Limit 2 L PID 8 Derivative Time Bank 7 SP Ramp Set Value To 00 us BU ud 4 co E3 DUDU EY lt OO E 4 pj OL 4 Bank 7 Alarm Value Set either of these parameters ooo E CES p E3 Oc i ce amp m 105 0 Bank 7 B LOLL EC Alarm Value 1 Bank 7 Alarm Value 3 Da oo us un co 4 l ppo LA E3 PID 8 MV Lower Limit oo Di r r Set either of these parameters Set either of these parameters
68. ng the body of the E5CN E5AN or E5EN from the case and never touch nor apply shock to the terminals or electronic components When inserting the interior of the product do not allow the electronic components to touch the case Always turn OFF the power supply before removing the terminal block from the E5GN and never touch nor apply shock to the terminals or electronic components 14 Do not use paint thinner or similar chemical to clean with Use standard grade alcohol 15 Design the system e g control panel considering the 2 seconds of delay that the product s output to be set after power ON 16 The output may turn OFF when shifting to certain levels Take this into consideration when performing control 17 The number of non volatile memory write operations is limited Therefore use RAM write mode when frequently overwriting data during communications or other operations 18 Always touch a grounded piece of metal before touching the Temperature Controller to discharge static electricity from your body 19 Do not remove the terminal block from the E5CN E5AN or E5EN Doing so may result in failure or malfunction 20 Control outputs for driving SSR that are voltage outputs are not isolated from the internal circuits When using a grounded thermocouple do not connect any of the control output terminals to ground Doing so may result in an unwanted circuit path causing error in the measured temperature 21 When replacing the b
69. o the ESAN HT or E5EN HT k4 Setup Tool port Approved UL 61010 1 CSA C222 No 1010 1 standards Standards Cort d ontormed EN 61010 1 IEC 61010 1 Pollution level 2 overcurrent category II standards EMI EN 61326 Radiated Interference Electromagnetic Field Strength EN 55011 Group 1 class A Noise Terminal Voltage EN 55011 Group 1 class A EMS EN 61326 ESD Immunity EN 61000 4 2 EMC Electromagnetic Field Immunity EN 61000 4 3 Burst Noise Immunity EN 61000 4 4 Conducted Disturbance Immunity EN 61000 4 6 Surge Immunity EN 61000 4 5 Power Frequency Magnetic Field Immunity EN 61000 4 8 Voltage Dip Interrupting Immunity EN 61000 4 11 1 The indication accuracy of K thermocouples in the 200 to 1300 C range T and N thermocouples at a temperature of 100 C max and U and L thermocouples at any temperatures is 2 C 1 digit max The indication accuracy of the B thermocouple at a temperature of 400 C max is not specified The indication accuracy of B thermocouples in the 400 to 800 C range is 3 C max The indication accuracy of the R andS thermocouples at a temperature of 200 C max is 3 C 1 digit max The indication accuracy of W thermocouples is 0 3 of PV or 3 C whichever is greater 1 digit max The indication accuracy of PL II thermocouples is 0 3 of PV or 2 C whichever is greater 1 digit max 2 Ambient temperature 10 C to 23 C to 55 C Voltage range 15 to 10 of rated voltage 3 K thermoc
70. ody of the E5CN E5AN or E5EN check the condition of the terminals If corroded terminals are used contact failure in the terminals may cause the temperature inside the E5CN E5AN or E5EN to increase possibly resulting in fire If the terminals are corroded replace the case as well When removing the terminal block of the E5GN to replace the Digital Temperature Controller check the condition of the terminals If corroded terminals are used contact failure in the terminals may cause the temperature inside the Digital Temperature Controller to increase possibly resulting in fire If the terminals are corroded replace the terminal block as well 22 Use suitable tools when taking the Temperature Controller apart for disposal Sharp parts inside the Temperature Controller may cause injury 23 When applying Lloyd s standards install the Digital Temperature Controller according to the requirements given in Shipping Standards 24 Do notuse the Temperature Controller if the front sheet is peeling off or torn 25 Check the orientation of the connectors on the Conversion Cable before connecting the Conversion Cable Do notforce a connector if it does not connect smoothly Using excessive force may damage the connector 26 Do not place heavy object on the Conversion Cable bend the cable past its natural bending radius or pull on the cable with undue force 27 Do not connect or disconnect the Conversion Cable while communications are in prog
71. omer does not perform periodic replacement The Waterproof Packing does not need to be attached if a waterproof structure is not required Current Transformers E54 CT1 21 28 F 5 8 dia rr 4 Y Q 7 5 3 Y 2 P 10 5 IT i 40 Two 3 5 dia n 10 D d d _ 30 MEN E54 CT3 2 36 dia Two M3 depth 4 o E54 CT3 Accessory e Armature Connection Example Armature Approx 3 dia e Plug AM Approx 6 dia E e L e E54 CT1 Thru current lo vs Output Voltage Eo Reference Values Maximum continuous heater current 50 A 50 60 Hz Number of windings 400 2 Winding resistance 18 2 Q 4 100V E50 Hz E gt 10 HER ie 1kQ Distortion on xH factor 10 v 1 8 3 9 196 4100 mV Bg O 10 100 Q 1 RL 10Q 100 uV 10 1 10 100mA 1 10 100 1 000A Thru current lo A r m s E54 CT3 Thru current lo vs Output Voltage Eo Reference Values Maximum continuous heater current 120 A 50 60 Hz Maximum continuous heater current foran OMRON Temperature Controller is 50 A Number of windings 400 2 Winding resistance 830 8 Q
72. one terminal Do not connect more than two wires or more than two crimp terminals to the same terminal Use the specified size of crimp terminals for wiring for the E5GN M3 0 width of 5 8 mm or less For open wired connections to the E5GN use stranded or solid copper wires with a gauge of AWG24 to AWG18 equal to a cross sectional area of 0 205 to 0 8231 mm The stripping length for screw terminals is 6 to 8 mm The stripping length for screwless clamp terminals is 10 mm The stripping length for auxiliary output 2 is 6 mm Up to two wires of the same size and type or two crimp terminals can be connected to one terminal Do not connect more than two wires or more than two crimp terminals to the same terminal Ferrules for screwless clamp terminals must be 0 8 to 1 4 mm in diameter and the exposed conductor must be 8 to 12 mm in length Ferrules for auxiliary output 2 must be 0 8 to 1 5 mm in diameter and the exposed conductor must be 6 mm in length N oO ES OMRON Safety Precautions for E5 IN E5 IN H E5 IN HT 6 Do not wire the terminals that are not used 7 To avoid inductive noise keep the wiring for the product s terminal block away from power cables carry high voltages or large currents Also do not wire power lines together with or parallel to product wiring Using shielded cables and using separate conduits or ducts is recommended Attach a surge suppressor or noise filter to peripheral devices that generate no
73. op Move to protect level time setting after a software reset B IM 17 Move to Protect Level E ITEM Displayed only when a password Protocol Setting iz is set Restricts moving to protect Switches between MV at PV Error level si CompoWay F SYSWAY and Modbus Operation Adjustment Protect sae SP used by Restricts displaying and Communications Unit No multi SP modifying menus in operation SP Ramp Set Value adjustment and manual control levels Initial Setting Communications PER Protect Baud Rate Xm is protect level restricts movement CompoWay F MV Upper Limit to the initial setting communications YSWAY onl i eae and advanced function setting gt only x1 When the PF Setting evels eres parameter is set to A M for a ata Leng MV Lower Limit Controller with a PF Key E5AN E5EN 2 When the PF Setting parameter is set to PFDP fora Communications Stop Bits PF Key Protect Restricts PF key operation EBAN ESEN only MV Change Rate Limit Parameter Mask Enable Displayed only when a parameter mask is set mL Communications Parity lt Controller with a PF Key EBAN EBEN Extraction of Square Root Low cut Point Password to Move to Protect Level Send Data Wait Time Password setting OMRON Operation for E5 N E5 N H E5 IN HT Monitor
74. ou can return to the operation level by executing a software reset 2 It is not possible to move to other levels from the calibration level by operating the keys on the front panel It can be done only by first turning OFF the power x3 From the manual control level key operations can be used to move to the operation level only x4 When the PF Setting parameter is set to A M for a Controller with a PF Key EBAN H ESEN H 5 When the PF Setting parameter is set to PFDP for a Controller with a PF Key E5AN H E5EN H 2 Error Displays Troubleshooting When an error occurs the No 1 display shows the error code Take necessary measure according to the error code referring the table below Status at error No 1 display Action Control output Alarm output rrun Input error Check the setting of the input type Also check the input wiring and check for broken wires Operates as above LUE IN PN S Err da T OFF Soup or short circuits in the temperature sensor the upper limit M A D Turn the power OFF then back ON again If the display remains the same the controller must Lt 4d 4 4 E333 converter be repaired If the display is restored to normal then a probable cause can be external noise OFF OFF error affecting the control system Check for external noise _ Memor Turn the power OFF then back ON again If the display remains the same the controller must Lt f h f E111 eot y be repaired If the display is restored to normal th
75. ouple at 100 C max 10 C max k4 External communications RS 232C RS 485 or RS 422 and cable communications for the Setup Tool can be used at the same time OMRON E5AN HT ESEN HT Program Control Number of programs patterns 8 Number of segments steps Segment setting method 32 Time setting Segment set with set point and time Gradient setting Segment type with set point gradient and time Segment times 0 h 0 min to 99 h 59 min 0 min 0 s to 99 min 59 s Alarm setting Set separately for each program Reset operation Startup operation S elect either stopping control or fixed SP operation S elect continuing resetting manual operation or run mode PID sets Number of sets 8 Setting method Set separately for each program automatic PID group selection also supported Alarm SP function Select from ramp SP and target SP Program status control Wait operation Time signals Program status output Program startup operation Segment operation Advance hold Program operation Program repetitions and program links Wait method Waiting at segment ends Same wait width setting for all programs Number of outputs 2 Number of ON OFF 1 each per output Operations Setting method Set separately for each program Program end output pulse width can be set run output stage output PV start Select from segment 1 set point slope priority PV sta
76. ply only on the net amount of invoices sent to Buyer after deducting transportation charges taxes and duties and will be allowed only if i the invoice is paid according to Omron s payment terms and ii Buyer has no past due amounts Interest Omron at its option may charge Buyer 1 1 2 interest per month or the maximum legal rate whichever is less on any balance not paid within the stated terms Orders Omron will accept no order less than 200 net billing Governmental Approvals Buyer shall be responsible for and shall bear all costs involved in obtaining any government approvals required for the impor tation or sale of the Products Taxes All taxes duties and other governmental charges other than general real property and income taxes including any interest or penalties thereon imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture production sale delivery importa tion consumption or use of the Products sold hereunder including customs duties and sales excise use turnover and license taxes shall be charged to and remitted by Buyer to Omron Financial If the financial position of Buyer at any time becomes unsatisfactory to Omron Omron reserves the right to stop shipments or require satisfactory security or payment in advance If Buyer fails to make payment or otherwise comply with these Terms or any related agreement Omron may without liabil ity and in ad
77. r burning may occasionally occur Always consider the application conditions and use the output relays within their rated load and electrical life expectancy The life expectancy of output relays varies considerably with the output load and switching conditions Tighten the terminal screws to the rated torque of between 0 74 and 0 90 N m 3 Loose screws may occasionally result in fire Set the parameters of the product so that they are Suitable for the system being controlled If they are not Suitable unexpected operation may occasionally result in property damage or accidents A malfunction in the product may occasionally make control operations impossible or prevent alarm outputs resulting in property damage To maintain safety in the event of malfunction of the product take appropriate Safety measures such as installing a monitoring device on a separate line A semiconductor is used in the output section of long life relays If excessive noise or surge is impressed on the output terminals a short circuit failure is likely to occur If the output remains shorted fire will occur due to overheating of the heater or other cause Take measures in the overall system to prevent excessive temperature increase and to prevent fire from spreading Do notallow pieces of metal or wire cuttings to get inside the cable connector for the Support Software Failure to do so may occasionally result in minor electric shock fire or damage to eq
78. ress Product faults or malfunction may occur 28 Make sure that the Conversion Cable s metal components are not touching the external power terminals 29 Do not touch the connectors on the Conversion Cable with wet hands Electrical shock may result 30 Before using infrared communications correctly attach the enclosed Mounting Adapter to the cable for the Support S oftware When connecting the infrared port on the cable to the Support S oftware into the Adapter insert the connector to the specified line Communications may not be possible if the connector is not connected properly 31 Read the information provided in the catalog and manual and be Sure you understand it before attaching a Control Output Unit 32 Check the specifications of the Control Output Unit and use it correctly 33 For the power supply voltage input use a commercial power Supply with an AC input Do not use the output from an inverter as the power supply Depending on the output characteristics of the inverter temperature increases in the product may cause smoke or fire damage even if the product has a specified output frequency of 50 60 Hz OMRON Safety Precautions for E5 IN E5 IN H E5 IN HT Shipping Standards The E5CN E5CN H E5AN E5AN H EBEN and E5EN H comply with Lloyd s standards When applying the standards the following installation and wiring requirements must be met in the application Application Conditions 1 Installation Location
79. rges for removal or replacement thereof the non complying Product ii repair the non complying Product or iii repay or credit Buyer an amount equal to the purchase price of the non complying Product provided that in no event shall Omron be responsi ble for warranty repair indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were prop erly handled stored installed and maintained and not subject to contamina tion abuse misuse or inappropriate modification Return of any Products by Buyer must be approved in writing by Omron before shipment Omron Compa nies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components circuits system assemblies or any other materials or substances or environ ments Any advice recommendations or information given orally or in writing are not to be construed as an amendment or addition to the above warranty See http www omron247 com or contact your Omron representative for pub lished information Limitation on Liability Etc OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies
80. rt 0 h 0 min to 99 h 59 min Standby 0 day 0 h to 99 day 23h Operation end operation S elect from resetting continuing control at final set point and fixed SP control Program SP shift Same program SP shift for all programs OMRON USB Serial Conversion Cable Applicable OS Windows 2000 XP Vista or 7 Applicable software CX Thermo version 4 or higher Applicable models E5AN ESEN ESCN ESCN U E5AN H E5EN H E5CN H E5AN HT E5EN HT E5CN HT E5GN USB interface standard Conforms to USB Specification 1 1 DTE speed 38400 bps Connector specifications Power supply Computer USB type A plug Temperature Controller Setup Tool port on bottom of Controller Bus power Supplied from USB host controller Power supply voltage 5 VDC Current consumption 70 mA Ambient operating temperature 0 to 55 C with no condensation or icing Ambient operating humidity 10 to 80 Storage temperature 20 to 60 C with no condensation or icing Storage humidity 10 to 80 Altitude 2 000 m max Weight Approx 100 g Note A driver must be installed in the personal computer Refer to installation information in the operation manual for the Conversion Cable Communicatio Transmission line connection method Communications ns Specifications RS 485 RS 422 Multipoint RS 232C Point to point RS 485 two wire half duplex RS 422 four wire ha
81. sed for control output 1 or 2 For these 4 0 0 0 combinations maintain the following mounting space between pog 14 Controllers B t l Ff 110 min pe aed oC E5AN H zi _ Z Terminal Cover Waterproof Mounting Bracket E53 COV16 Packing Accessory Accessory Accessory l 9202 Crimp terminal size M3 5 120 min OMRON E5EN HT aa _ _t ach IL PII i Bi c c c EH LL Il t 1l cm c Ail PET F Oo a Er PEE CAAA ILL lo en ee 91 BARNES IL PTS cec uU c PI i LI cC Ds ccc ul a i Terminal Cover Waterproof Mounting Bracket E53 COV16 Packing Accessory Accessory Accessory Crimp terminal size M3 5 E5AN HT ESEN HT Mounted Separately Group Mounted st 120 min 48 x number of units 2 5 1 L 4 927 Y la Group mounting does not allow waterproofing e Recommended panel thickness is 1 to 8 mm e Group mounting is notpossible in the vertical direction Maintain the specified mounting space between Controllers e When two or more Controllers are mounted make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications Group mounting is not possible ifan E53 C3N or E53 C3D
82. t Input output cycle Assignment 4 B r rp Control Period Cooling Es ay Closed Floating Direct Reverse Operation Motor Calibration E HL L Alarm 1 Type jel a B Mak Travel Time co a sm au ci Alarm 1 co Hysteresis B GQK Extraction of Square ae ARE Root Enable co Move to Advanced Function a M 1 Setting Level g Ra Displayed when initial Li setting communications protect is set to 0 ce Move by setting password 169 OMRON Operation for E5 N E5 N H E5 IN HT Power ON Manual Control Level eeeees cieees PEeeeeeeeeeceeceeeceeoeoeeeeeneeoeeeoeoeoeoo eeelieeeeoeeo ooccooot e Operation Level Monitor Setting Adjustment Bank Setting PID Setting Level Level Level oa Protect Level Item Level D O reeereeeeoeeoedeoceoeoee see See eee PDoocoocoocoooooooowo omococoocococOoOooOoOoocooocoocoon e en Press the EJ Th H LILE El Bs Orr co ca coo e OPRL M ono UNI co e l e FEGE io Bes A co int E Sh uM mi EEG N a co ij m B She m CER N n rB 14 i cc CS ia Li D D zz ce 4j UN
83. ternately tighten the two screws little by little to maintain a balance Tighten the screws to a torque of 0 29 to 0 39 N m Mounting the Terminal Cover E5CN Make sure that the UP mark is facing up and then attach the E53 COV17 Terminal Cover to the holes on the top and bottom of the Temperature Controller E5AN E5EN Slightly bend the E53 COV16 Terminal Cover to attach it to the terminal block as shown in the following diagram The Terminal Cover cannot be attached in the opposite direction uu C i Y a UN 7A i ZS as et S lightly bend the E53 COV16 Terminal Cover in the direction shown by the arrows to attach it to the terminal block y ae VI v pes Me ess al ll m ine en 1 s E53 COV16 Terminal Cover Accessory Removing the Temperature Controller from the Case The Temperature Controller can be removed from the case to perform maintenance without removing the terminal leads This is possible for only the E5CN E5AN and E5EN and not for the E5CN U or E5GN Check the specifications of the case and Temperature Controller before removing the Temperature Controller from the case E5CN Tool insertion hole Flat blade screwdriver Unit mm 1 Inserta flat blade screwdriver into the two tool insertion holes one on the top and one on the bottom to release the hooks 2 Insertthe flat blade screwdriver in the gap bet
84. the E5CN E5AN or EBEN and 6 to 8 mm for the E5GN Use crimp terminals when wiring the terminals Use the suitable wiring material and crimp tools for crimp terminals Tighten the terminal screws to a torque of 0 5 N m for the ESCN U and E5GN and to 0 74 to 0 90 N m for other models The terminal torque is 0 5 to 0 6 N m for auxiliary output 2 on the E5GN terminals for M3 5 screws For the E5CN E5AN or E5EN use the following types of crimp r 7 2 mm max EN SCrews For the E5GN use the following types of crimp terminals for M3 0 F C 58mm max t O 5 8 mm max For E5GN screwless clamp terminal blocks use wires with a gauge of AWG24 to AWG18 equal to a cross sectional area of 0 205 to 0 823 mm The length of the conductive portion inserted into the terminal must be 10 mm for wires and 8 to 12 mm for ferrules Ferrules must be 0 8 to 1 4 mm in diameter 0 8 to 1 4 E 8 to 12 mm ine Ferrules wires e Recommended Ferrules for E5GN Screwless Clamp Terminals Manufacturer Altech Corp Daido Solderless Terminal Mfg Co J S T Mfg Co Model number 2623 0 AVA 0 5 TUB 0 5 Single 1 wire Nichifu Co TGNTC 1 25 9T TGVTC 1 25 11T TGNTC 1 25 11T TC0 3 9 5 TC1 25 115 ST TC1 25 115 TC2 115 Double 2 wires TGWVTC 1 25 9T TGWVTC 1 25 11T OMRON Safety Precautions for E5 IN E5 IN H E5 IN HT e Use wires with a gauge of AWG24 to AWG 18 0 205 to 0 823 mm for
85. tions and licenses regarding i export of products or information iii sale of products to forbidden or other proscribed persons and ii disclosure to non citizens of regulated technology or information Miscellaneous a Waiver No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron b Assignment Buyer may not assign its rights hereunder without Omron s written consent c Law These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products without regard to conflict of law princi ples d Amendment These Terms constitute the entire agreement between Buyer and Omron relating to the Products and no provision may be changed or waived unless in writing signed by the parties e Severability If any provi sion hereof is rendered ineffective or invalid such provision shall not invalidate any other provision f Setoff Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice g Definitions As used herein including means including without limitation and Omron Compa nies or similar words mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof Certain Precautions on Specifications and Use 1 Suitability of Use Omron Companies shall not be responsible for co
86. uipment S 900k OOOOObPD Do not allow dust and dirt to collect between the pins in the connector on the Conversion Cable Failure to do so may occasionally result in fire When inserting the body of the Temperature Controller into the case confirm that the hooks on the top and bottom are securely engaged with the case If the body of the Temperature Controller is not inserted properly faulty contact in the terminal section or reduced water resistance may occasionally result in fire or malfunction When connecting the Control Output Unit to the socket press it in until there is no gap between the Control Output Unit and the socket Otherwise contact faults in the connector pins may occasionally result in fire or malfunction 1 An SELV circuit is one separated from the power supply with double insulation or reinforced insulation that does not exceed 30 V r m s and 42 4 V peak or 60 VDC 2 A class 2 power supply is one tested and certified by UL as having the current and voltage of the secondary output restricted to specific levels 3 However use the following tightening torques E5CN U 0 5 N m E5GN 0 43 to 0 58 N m auxiliary output 2 of ESGN 0 5 to 0 6 N m Precautions for Safe Use Be sure to observe the following precautions to prevent malfunction or adverse affects on the performance or functionality of the product Not doing so may occasionally result in faulty operation 1 This product is specific
87. ulti SP Uses 5 CLE B i roe Em OFF Em SFF ES mmu ea l l Cel EBAN ESEN only arm e YP o r rmm SP Ramp Time Unit i H dl L Alarm 3 Latch HS Alarm Hysteresis Br de Monitor Setting Item 2 o 7 T o an oO LL 5 3i ne S r e ri FE M EIE Er ooo ut Alarm 3 co Se v ke Hysteresis H DIE CL Standby Sequence g BRL E Move to Protect Level LBA Detection Time 5 PF 4 3 Monitor Setting Item 3 B ML Ar Reset Iz Time e m Eon n H 000 LI aad r1 Transfer Output Type l co 1 co 7 LBA Level 2 nr Iu i Linear output E GE IN Auxiliary Output 1 Input Error Output 2 PEdH Monitor Setting Item 4 ca wx Open in Alarm El Ll cra INC EI Transfer Output co Upper Limit le v 2 EL Jn Auxiliary Output 2 H r Ir Cold Junction LBA Band a jr r 4 Monitor Setting Item 5 5 Joc g LUL Compensation ee coy N S Open in Alarm ser gN Method acc L Transfer Output Lower Limit co J ili 2 pn mi MB Command 9 Cos PV SP Display nt oid g MLM Logic Switching Fea 5 HI Screen Selection Open in Alarm oom OFF Ens 4 inear Current Output i ll co I co Linear output HB ON OFF AL R PV Change Color Control Output 2 B ati MV Display Selection Bes DCJ Assignment EL T T X 200 veo EX a f pred of Multi SP Uses wo SPs 1 I co Four SPs 2 Heater Burnout Latch PV Stable Band Auxiliary Output 1 B By 40 PV Decimal Point Assignment i Display EHE on Event Input Assignment 1 Se Auxiliary Output 2 2 psec PV Status Display Heater Burnout a HBcL e
88. ures Main I O Functions E5AN HT E5EN HT Remote SP Input e One ed 2 Event Inputs None e Two Four Three displays for simultaneous display of the PV SV program and segment 5 digit Display with high resolution of 0 01 C e Programmable function 8 programs x 32 segments Auto manual switching Temperature Controller status display d Thermocouple Pt Input Computer Support Software e Simple program 0 1 of PV CX Thermo function e Analog input i Logic operations 0 1 FS Control output ON OFF count alarm PV change rate alarm e Models available with RS 485 RS 422 or RS 232C communications Universal Sensor Inputs Universal thermocouple Pt analog ENE HN eee eee eee ee ee gt Auxiliary Outputs current voltage inputs e Two Indication Accuracy Control Output 2 Output Unit e Relay output e Voltage output for driving SSR e Current output e Linear voltage output Sampling Period e 60 ms PF Key Programmable key function Control Output 1 Output Unit Relay output Voltage output for driving SSR Current output Linear voltage output Lineup E5AN HT E5EN HT Programmable Type Tego hele Fully universal input E5AN HT ESEN HT control output 2 auxiliary outputs 2 auxiliary outputs 2 control outputs Note The Controller can be used for heating cooling control even if only 1 control outp
89. urrent 2 g t JL Alarm Value Monitor EC np Lower Limit 3 co 8 M 5 Mat Stop E B ES nn Program Start E nn MV Monitor Heating le E M_E TT 2 a MVat PV Error Soak Time Remain B z s MV Monitor Cooling ooo ooo LIL le Sr OL E B 5PRE sp Ramp Set Value S V M Valve Opening En E ag Monitor co B H ae 5 MV Upper Limit Em 1050 e nL L B on MV Lower Limit PF Key 2 E nh m o Ex gg MV Change Rate Limit Monitor Setting Item Level ESAN H ESEN H only S g E LS 3 E Monitor Setting PF B8 Monitor Setting PF E Monitor Setting m nm ES Ex pi Item Display 1 EN Item Display 2 EE Item Display 3 PF e n Open Close Hysteresis m coo B Monitor Setting B Monitor Setting D Item Display 4 8 Item Display 5 H Oe 5 GRP Extraction of Square gt a E 2L B Root BBS Low cut Point Note The monitor setting items to be displayed is set in the Monitor Setting Item 1 to 5 parameters advanced function setting level PF Key 2 1 When the PF Setting parameter is set to A M for a Controller with a PF Key E5AN H E5EN H 2 When the PF Setting parameter is set to PFDP for a Controller with a PF Key E5AN H E5EN H OMRON Operation for E5_ N E5_ N H E5_ N HT Press the O Key for at least 1 s Press the O Key for at least 3 s Other than the Auto Manual Switch display Initial Setting Level Press the O Key less than 1 s Pr
90. ut is used Model Number Structure Model Number Legend Controllers E5AN ESEN 1 1 1 1l 1L 1IML j 1 500 123456789 10 11 1 Type HT Programmable 2 Control Mode Blank Standard or heating cooling control P Position proportional control 3 Control Output 1 A Control Output Unit R Relay output 4 Control Output 2 A Control Output Unit R Relay output 5 Auxiliary Outputs 2 Two outputs 3 Three outputs 6 Option 1 Blank None H Heater burnout S SR failure Heater overcurrent detection CT 1 HH Heater burnout SSR failure Heater overcurrent detection CT2 7 Option 2 B Two event inputs BF Event input Transfer output 8 Option 3 M Option Unit can be mounted 9 Power Supply Voltage Blank 100 to 240 VAC D 24 VACNDC 10 Case Color Blank Black 11 Terminal Cover 500 With Terminal Cover Option Units E53 7 1 1 Function ENOI1 RS 232C communications EN02 RS 422 communications EN03 RS 485 communications AKB Event input Output Units E53 12 1 Control Output R Relay output Q Voltage output for driving SSR Q3 Voltage output for driving SSR 24 VDC NPN Q4 Voltage output for driving SSR 24 VDC PNP C3 Current output 4 to 20 mA DC C3D Current output 0 to 20 mA DC V34 Linear voltage output 0 to 10 VDC V35 Linear voltage output 0 to 5 VDC 2 Version Blank Available for ESAN H E5EN H E5AN HT E5EN HT and E5AK E5EK N Available only for
91. ween the front panel and rear case and pull out the front panel slightly Hold the top and bottom of the front panel and carefully pull it out toward you without applying unnecessary force 3 When inserting the body of the Temperature Controller into the case make sure the PCBs are parallel to each other make sure that the sealing rubber is in place and press the E5CN toward the rear case into position While pushing the E5CN into place push down on the hooks on the top and bottom surfaces ofthe rear case so thatthe hooks are securely locked in place Be sure that electronic components do not come into contact with the case OMRON Safety Precautions for E5 IN E5 IN H E5 IN HT E5AN E5EN Tool insertion 7 it ar AMA AW ae A PAM gogo E5AN E5AN 1 E5EN 1 Inserta flat blade screwdriver into the two tool insertion holes one on the top and one on the bottom to release the hooks 2 Insertthe flat blade screwdriver in the gap between the front panel and rear case two on the top and two on the bottom and use it to pry and pull out the front panel slightly Then pull out on the front panel gripping both sides Be sure not to impose excessive force on the panel 3 When inserting the body of the Temperature Controller into the case make sure the PCBs are parallel to each other make sure that the sealing rubber is in plac
92. will package Products as it deems proper for protection against nor mal handling and extra charges apply to special conditions Claims Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original trans portation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed Warranties a Exclusive Warranty Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron or such other period expressed in writing by Omron Omron disclaims all other warranties express or implied b Limitations OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED ABOUT NON INFRINGEMENT MERCHANTABIL 14 ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or oth erwise of any intellectual property right c Buyer Remedy Omron s sole obli gation hereunder shall be at Omron s election to i replace in the form originally shipped with Buyer responsible for labor cha