Home
Specification and compliance sheet - NPCIL e
Contents
1. d Logging function with trend Capture for documenting the performance of designs processes or systems or unattended monitoring while work on other projects Plots measurements as a single line to help detect signal anomalies over time Using on board trend capture graphically view logged readings without a PC e Log multiple sessions or log data continuously for over 200 hours f On board screens for measurement functions g Real Time Clock for automatic time stamping of saved readings h Min Max Average with Time Stamp to record signal fluctuations i Soft keys scroll buttons and easy navigation control access to secondary functions j True rms ac voltage and current for accurate measurements on complex signals or non linear loads k Relative mode to remove test lead resistance from low ohms or capacitance measurements I Peak capture to record transients as fast as 250 us m Included premium test leads and alligator clips n Elapse time clock o Time of day clock p Min Max Avg q Hold feature r Isolated Optical Interface s Auto Touch Hold feature t Reading memory feature u Log to PC v Interval Event Logging feature w Electromagnetic Compatibility EMC EN6 1326 1 x Vibration Random vibration per MIL PRF 28800 f Class 2 y Shock 1 met
2. 005 Resolution 0 001 Hz 0 01 Hz 0 0001 kHz 0 001 kHz 0 01 kHz 10 Temperature Range 200 0 C to 1350 0 C excluding probe Accuracy 1 0 Resolution 0 1 C 11 True rms AC 100 kHz bandwidth 12 Conductance 50 00 nS 13 Peak 250 uS 14 Duty Cycle 0 01 to 99 99 Resolution 0 01 15 Pulse Width 0 025 ms 0 25 ms 2 5 ms 1250 0 ms Resolution 0 0001 ms 0 001 ms 0 01 ms 0 1 ms 16 Logging Memory Up to 10 000 readings 17 Environmental a Operating temperature up to 55 C Specifications b Storage temperature up to 60 C c Humidity without condensation up to 70 35 C 50 C 18 Safety a Overvoltage category EN 61010 1 to1000V Specifications CAT Ill EN 61010 1 to 600 V CAT IV b Agency approvals UL CSA TUV 19 Warranty Limited lifetime warranty 20 Battery type 6 AA alkaline batteries NEDA 15A IEC LR6 21 Battery life 100 hours minimum 200 hours in logging mode 22 Other features a Should have zoomed on trend unprecedented ability to view analyze Trend Capture data see detail at X5 magnification b Simplified record screen when setting up recording c Logging function with expanded memory for unattended monitoring of signals over time Using on board trend capture can graphically review logged readings without needing a PC Store up to 15 000 recorded events
3. Annexure l Must be submitted with offer Indent Computer No 9224 Specification and compliance sheet Note Mention Yes or No in respective column a Item No 1 3 1 2 Digit 6000 Counts True RMS Digital Multimeter To mention here the offered Make and Model No Sr Parameter Specifications Compliance No by the bidder Yes No 1 Digital Display 3 1 2 digit updates 4 times sec 6000 counts Analog bar graph with backlight 2 DC Voltage Range 0 1mV to 1000V Accuracy 0 09 2 Resolution 0 1mV 3 AC Voltage Range 0 1mV to 1000V Accuracy 1 0 3 Resolution 0 1mV true RMS 4 Continuity Beeper guaranteed on lt 25 Q detects opens or shorts of 250 u sec or longer 5 DC Current Range Max 10A 20A over range for 30 seconds Accuracy 1 0 3 Resolution 0 01 A 6 AC Current Range Max 10 A 20 A over range for 30 sec Accuracy 1 5 3 Resolution 0 01 A 7 Resistance Range Max 50MQ Accuracy 0 9 1 Resolution 0 1 Q 8 Capacitance Range Max 10 000 uF Accuracy 1 2 2 Resolution 1nF 9 Frequency Range Max 100 kHz Accuracy 0 1 1 Resolution 0 01 Hz 10 Temperature Range 40 C 400 C Accuracy 1 0 10 Resolution 0 1 C 11 Environmental a Operating temperature up to 50 C ppeciiealions b Storage temperature up to 60 C c Humi
4. dity without condensation up to 70 35 C 50 C 12 Safety a Overvoltage category EN 61010 1 to 1000V Specifications i CAT Ill EN 61010 1 to 600 V CAT IV b Agency approvals UL CSA TUV 13 Warranty Limited lifetime warranty 14 Battery type 9V alkaline battery 15 Battery life Alkaline 200 hours typical without backlight 16 Other features a Manual and automatic ranging b Display Hold and Auto Hold c Diode measurements d Min max average recording e Closed case calibration through front panel f Ergonomic case with integrated protective holster g Built in probe holders for probe storage and for convenience when making measurements h Size HxWxD approximate 190 mm x 85 mm x 45 mm i Weight 450 gm or less 17 Included a Temperature Probe accessories b 9 V battery c Test leads d User s manual 18 Note a Valid authorization certificate required from OEM without which offer will not be considered b Calibration Test certificate to be provided along with the instrument c Training Demo of equipment required at site after delivery b Specification of Item No 2 4 1 2 Digit 50 000 Counts Digital Multimeter To mention here the offered Make and Model No Sr Parameter Specifications Complianc
5. e No by the bidder Yes No 1 Digital Display Large 50 000 count 1 4 inch VGA display with white backlight Multiple sets of measurement information can simultaneously be displayed at the same time 2 DC Voltage Range 50 000 mV 500 00 mV 5 0000 V 50 000 V 500 00 V 1000 0V Accuracy 0 025 Resolution 0 001mV 0 01mV 0 0001V 0 001V 0 01V 0 1V 3 AC Voltage Range 50 000 mV 500 00 mV 5 0000 V 50 000 V 500 00 V 1000 0V Accuracy 0 4 true rms Resolution 0 001mV 0 01mV 0 0001V 0 001V 0 01V 0 1V 4 Continuity Beeper guaranteed on lt 25 Q detects opens or shorts of 250 u sec or longer 5 DC Current Range 500 00 uA 5000 0 A 50 00 mA 400 00 mA 5A 10A Accuracy 0 15 Resolution 0 01 yA 0 1 uA 0 001 mA 0 01 mA 0 0001A 0 001A 6 AC Current Range 5 0000 A 10 000 A Accuracy 0 7 true rms Resolution 0 01 yA 0 1 uA 0 001 mA 0 01 mA 0 0001A 0 001A 7 Resistance Range 500 00 Q 5 0000 kQ 50 000 kQ 500 00 kQ 5 0000 MQ 30 00 MQ 50 00 MQ 500 00 MQ Accuracy 0 05 Resolution 0 01 Q 0 0001 kQ 0 001 kQ 0 01 kQ 0 0001 MQ 0 001 MQ 0 01 MQ 0 1 MQ 8 Capacitance Range 1 000 nF 10 00 nF 100 00 nF 1 000 uF 10 00 uF 100 0 uF 1000 uF 10 00 mF 100 00 mF Accuracy 1 0 Resolution 0 001 nF 0 01 nF 0 1 nF 0 001 uF 0 01 uF 0 1 uF 1 uF 0 01 mF 0 1 mF 9 Frequency Range 99 999 Hz 999 99 Hz 9 9999 kHz 99 999 kHz 999 99 kHz Accuracy 0
6. er drop per IEC EN 61010 1 2nd edition z Size HxWxL approximate 22 2 cm x 10 2cm x 6 cm 8 75 in x 4 03 in x2 38 in aa Weight 880 g or less 23 Included a User s manual accessories b 6 AA Batteries c Silicone Test Leads d Probe Holder e Two Alligator Clips 24 Note a Valid authorization certificate required from OEM without which offer will not be considered b Calibration Test certificate to be provided along with the instrument c Training Demo of equipment required at site after delivery