1. Table 10 Pin out for Microchip MPU In Circuit Programmer Loader User Manual Revision 1 10 Page 23 Appendix A 10 pin connector 7 10 Pin out for EXAR XRP77xx Family Pin Pin Name Direction Description 1 CEO OUT 2 ME OUT 3 CE1 OUT 4 LOC_PWR P 5 CE2 OUT 6 SCLK OUT 7 CE3 OUT 8 SDA B 9 CE4 OUT 10 GND P Table 10 Pin out for EXAR XRP77xx Family 7 11 Pin out for TI MSP430 Family Pin Pin Name Direction Description 1 TCLK OUT 2 N C N C 3 TDO TDI IN OUT 4 LOC_PWR P 5 N C N C 6 N C N C 7 N C N C 8 N C N C 9 N C N C 10 GND P Table 11 Pin out for TI MSP430 Family Spy Bi Wire In Circuit Programmer Loader User Manual Revision 1 10 Page 24 Appendix A 10 pin connector In Circuit Programmer Loader User Manual Revision 1 10 Page 25 Appendix B DIP Switch Description Appendix B DIP Switch Description eLoader uses multipurpose dip switch for operation and debugging purposes The default manufacture setting is OFF for all positions OFF 1 Z E ON Figure 8 Multipurpose DIP switch Position Description 4 This position enables configuration or operation modes If the position 1 is set to ON the configuration mode is enabled Otherwise the operation mode is enabled 3 Currently not used 1 2 These positions enable or disable different operation debug mode
2. Table 2 Pin out for JTAG interface In Circuit Programmer Loader User Manual Revision 1 10 Page 19 Appendix A 10 pin connector 7 2 7 3 Pin out for JTAG and 12C interfaces Pin Pin Name Direction Description 1 TCLK OUT 2 ME OUT Master access indication set 1 when access to I2C bus 3 TDO IN 4 VCC P 5 TMS OUT 6 SCLK OUT 7 TRST OUT 8 SDA B TDI OUT 10 GND P Table 3 Pin out for JTAG and I2C interface multiple interface configurations Pin out for JTAG and SPI interface Pin Pin Name Direction Description 1 TCLK OUT 2 ME OUT Master access indication set 1 when access to SPI bus 3 TDO DO IN 4 VCC P 5 TMS OUT 6 SCLK OUT 7 TRST OUT 8 CS B 9 TDI DI OUT 10 GND P Table 4 Pin out for JTAG and SPI interface multiple interface configurations In Circuit Programmer Loader User Manual Revision 1 10 Page 20 Appendix A 10 pin connector 7 4 Pin out for I2C interface Pin Pin Name Direction Description 1 N C N C 2 ME OUT Master access indication set 1 when access to I2C bus 3 N C N C 4 VCC P 5 N C N C 6 SCLK OUT 7 N C N C 8 SDA B N C N C 10 GND P Table 5 Pin out for DC interface 7 5 Pin out for SPI interface Pin Pin Name Direction Description 1 N C N C 2 ME OUT Master access indic
3. TDI TDO TRST Description Current project description Data File Data file in XSVF or SVF formats FLASH EEPROM with I2C interface Target device FLASH EEPROM Interface DC SDA SDC Description Current project description Data File Data file in HEX Motorola S Record Binary formats DC Cfg File Custom I2C configuration file for target device created by ELoaderConfig FLASH EEPROM with SPI interface Target device FLASH EEPROM Interface SPI SCK SCS SDI SDO Description Current project description Data File Data file in HEX Motorola S Record Binary formats Device Select target device from the list M25POSA M25P10A M25P128 M25P16 M25P20 M25P32 M25P40 M25P64 M25P80 Verify Data Verify data after programming it In Circuit Programmer Loader User Manual Revision 1 10 Page 7 Configuration 44 Microchip MCU DSP Target device Microchip MCU DSP Chip Family Select Microchip family from the list dsPIC30 dsPIC33 PIC24 Device ID Select Microchip device id Description Current project description Data File Data file in HEX format 4 5 FPGA configuration device Target device FPGA Configuration Device Interface Select FPGA Configuration device Description Current project description Data File Data file in RPD format raw programming data 4 6 Silicon Labs MCPU with JTAG interf
4. ae ea Eed A aaa ARAA 26 ELoaderConfig utility main dialog eccccececeeeeeceeneeceeeeeeeeaeeeeneeseaeeecaaeeeeaaesecaeeesaaeseeaeeseaeeeeaees 27 Figure 10 EasyLoader Custom Configuration dialog s 28 Tables Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9 Table 10 Table 11 Debugging mode switch setting 18 Pin out for J TAG interface iii 19 Pin out for JTAG and 12C interface multiple interface configurations 20 Pin out for JTAG and SPI interface multiple interface configurations 20 Pin o t for Kl 21 PIN OUt Of SPI Win 21 Pin out for Altera FPGA EPCSxxx devices sise 22 Pin out for Atmel AT17LVxxx devices usines 22 Pin out for Silicon Labs MP 23 Pin out for EXAR XRP77xx Family iii 24 Pin out for TI MSP430 Family Spy Bi Wire us 24 In Circuit Programmer Loader User Manual Revision 1 10 Page iv 1 1 1 2 1 3 1 4 About this Document Purpose This document describes installation and operation of AMFELTEC Corp In Circuit Programmer Loader EasyLoader Feedback AMFELTEC makes every effort to ensure that the information contained in this document is accurate and complete at time of release Please contact AMFELTEC if you find any errors inconsistencies or have trouble understanding any part of this document To provide your feedback please send an email to support amfeltec com Your comm
5. command will provide you options to modify the configuration parameters In Circuit Programmer Loader User Manual Revision 1 10 Page 27 Appendix C EasyLoader Configurator 9 1 9 2 The Save command will save current configuration parameters into file EasyLoader Custom Configuration Dialog EasyLoader Custom Configuration dialog displays single parameter of the target device and wat for the value Configuration Parameter 12C control code hex Figure 10 EasyLoader Custom Configuration dialog When you click on Next button the current configuration parameter will be saved in configuration structure and next parameter will show up When you click on Prev button the current configuration parameter will be saved in configuration structure and previous parameter will show up When you click on Close button the current configuration parameter will be ignore and control will be returned to the main dialog EasyLoader Export Configuration Command EasyLoader Configurator includes feature that allowed to user to export target device configuration into text file To execute this command click on top left corner of EasyLoader Configurator main dialog and then Export Configuration In Circuit Programmer Loader User Manual Revision 1 10 Page 28 9 3 Appendix C EasyLoader Configurator DC Configuration parameters The following list of parameter describe the required information about I2C target device that you
6. the target device and interface type Depending on your selection different dialog controls will become visible Provide all necessary information see Appendix A and click on Add Project The EasyLoader application will analyze the data and create the project You will see it in a project window e Ifyou want to add another project you can now select new target device interface type and provide additional information When done click Add The new project will be added after the previous project and application will update the memory used bar fe Amfeltec EasyLoader Update ver 2 1 2 Firmware ver 3 4 8 Configuration Project ER Description Te Target device Silicon Labs MCPU v Interface K Chip Family CB051F30x DevicelD C8081F305 Verify Data M Protect Data Iv Project Target Interface Size File list FPGA CPLD JTAG 511 Samplel xsvf 2 SiiconLabs C2 255 Sample2 hex verify protect Samples2 with description Memory used E 4 total 16 MByte EIS Port Control Connected COME Disconnect Remove d Clear All Controls Update Verity Get Data Open Project Save Project ine EW Update Help Close d Figure 5 eLoader project with description In Circuit Programmer Loader User Manual Revision 1 10 Page 13 Operation 5 1 3 2 5 1 3 3 5 1 4 5 1 5 5 1 6 5 1 7 5 1 8 You can add as many projects a
7. In Circuit Programmer Loader User Manual April 28 2011 Revision 1 10 Amfeltec Corp www amfeltec com Copyright 2007 2010 Amfeltec Corp 35 Fifefield dr Maple ON L6A 1J2 Contents Contents 1 ABOUT this Te 1 1 1 lire 1 152 Feedback 325 ie cheb cache naines SEENEN oen 1 EC Abbreviation ecient Wace eel bie Ain Gated dain ets deci Aan ds 1 EEN Ef Ee 1 2 General DESCriPUO MN rss dites deed soe acpi ecats ata aad casa chai aE eege 3 2 1 lte ULT EE 3 22 HOW It WORKS nt TR na As O Aa ee danS 4 23 e lee EE 5 2 3 1 Board Assembly House 5 2 3 2 Update Firmware prior to Shipping eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseaeeeeaaeeeeeeeeeeees 5 2 3 3 Remote Firmware Update A 5 2 3 4 Seille Rent E reer Crete M ner ri 5 3 IC UE el I 222285 Ruth that ahtiten Na ae ea nette auree 6 St Software Installati n 55 588 hs drames enets es dE dates street tenter e lent ere dies tan dee 6 3 2 Device Driver Installation for eLoader 00 2 eeeeeeeeceeeeeeeeceeeeeeeeeeeeeeeeaeeesaaeeeeaeeseeeeeseaeeeenaeeeeaes 6 4 CONIQUFAION EE 7 4 1 XILINX FPGA CPLD with JTAG interface 0 00 ccceecceeceeeeeeeeeeeeeeeeesaeecaaecaaeeaaeseaeeeaeeeaeeeaeees 7 4 2 FLASH EEPROM with DC mtertace sis 7 4 3 FLASH EEPROM with SPI interface ccccceecceeseeeseeeeeeeeeeeeeeceeesaaeceaeseaeseaeseeeeeeeeeeeeatees 7 4 A Microchip MCU DSP sir cat casevstccecentes tu fan dde ge sitter met f earnap anlee a di desde teen 8 4 5 FPGA configuration device
8. Parity None Stop bits 1 Flow control None eLoader supports 3 levels of debugging that can be enabled by using main dip switch position 1 and 2 located on top side In Circuit Programmer Loader User Manual Revision 1 10 Page 17 Troubleshooting Debug Level Description Dip switch position Level 0 Defines default debug level and prints only main information header and status of each project ON OFF 1 4 e Level 1 Includes extra debugging information like project header details OFF Level 2 Includes full debug information WARNING Please use this option ONLY if you are advised by Amfeltec tech support Table 1 Debugging mode switch setting In Circuit Programmer Loader User Manual Revision 1 10 Page 18 7 1 Appendix A 10 pin connector Appendix A 10 pin connector eLoader device uses 10 pin connector Figure to connect to target device 9 5 3 1 10 6 4 2 Figure 7 Connector 10 pin to target device The following tables show pin assignment of 10 pin connector depending of selected target device and interface type direction OUT means output from eLoader Pin out for JTAG interface Pin Pin Name Direction Description 1 TCLK OUT 2 N C N C 3 TDO IN 4 VCC P Power from target 5 TMS OUT 6 N C N C 7 TRST OUT 8 N C N C 9 TDI OUT 10 GND P Ground from target
9. Update The following dialog will show up el Amfeltec Easyioader Update Configuration Port Control Project In Description Disconnected Target device LIN FPGA CPLD PA Interface ITA MS TCK TDI TDO TAST v Connect JP Project Target Interface Size File list Controls Memory used re HI Figure 3 EasyLoader main dialog Establish connection with eLoader Verify that position 4 of the DIP switch on eLoader device is in ON position This position enable eLoader device to be program using EasyLoader Update application In Circuit Programmer Loader User Manual Revision 1 10 Page 11 Operation Connect eLoader to USB port of your host computer If your computer was started you will see flashing GREEN LED on the eLoader z Amfeltec EasyLoader Update ver 2 1 2 Firmware ver 3 4 8 DER r Configuration Port Control Project Ia Description Connected Target device Silicon Labs MCPU el Interface C2 e OM Chip Family C8051F 30x xl Device ID cs051 F305 E Disconnect Hs Add Verify Data M Remove Protect Data V Clear All Project Target Interface Size File list Controls 1 FPG CPLD JTAG 511 Samplel xsvf 2 SiliconLabs C2 255 SampleZ hex verify protect Update Verify Get Data Open Project Save Project Pw Update Memory used ill 4 total 16 MByte Help Ready Close ck EEE Figure 4 EasyLoader Update main dialog with sample project The sys
10. ace Target device Silicon Labs MCPU Interface JTAG TMS TCK TDI TDO TRST Chip Family Select chip family device Device ID Select device ID Data File Data file in SVF format 4 7 Silicon Labs MCPU with C2 interface Target device Silicon Labs MCPU Interface C2 Chip Family Select chip family device Device ID Select device id In Circuit Programmer Loader User Manual Revision 1 10 Page 8 Configuration Data File Data file in HEX format Verify Data Verify data after programming it Protect Data Protect data after programming it 4 8 Altera FPGA CPLD with JTAG interface Target device Altera FPGA CPLD Interface JTAG TMS TCK TDI TDO TRST Data File Data file in SVF format 4 9 EXAR XRP77xx family Target device EXAR Description Current project description Device Select your current product device XRP7704 XRP7708 XRP7740 XRP7713 XRP7714 Slave address Provide slave address of your EXAR device if the target device was configured before to specific slave address different than 00 default Chip Enable If you have multiple EXAR device on your board connected in parallel and with the same slave address you can use Chip Enable parameter to specify active target device EasyLoader device supports up to 5 EXAR devices Data File HEX file to program Verify Data Verify data after programming Load
11. ation set 1 when access to SPI bus 3 DO IN 4 VCC P 5 N C N C 6 N C N C 7 SCLK OUT 8 CSL OUT 9 DI OUT 10 GND P Table 6 Pin out for SPI interface In Circuit Programmer Loader User Manual Revision 1 10 Page 21 Appendix A 10 pin connector 7 6 Pin out for Altera FPGA EPCSxxx devices Pin Pin Name Direction Description 1 DCLK OUT 2 N C N C 3 DATA IN 4 VCC P 5 nCONFIG OUT 6 N C N C 7 nCE OUT 8 nCS OUT 9 ASDI OUT 10 GND P Table 7 Pin out for Altera FPGA EPCSxxx devices 7 7 Pin out for Atmel AT17LVxxx devices Pin Pin Name Direction Description 1 SCLK OUT 2 N C N C 3 N C N C 4 VCC P 5 N C N C 6 SER_EN OUT 7 N C N C 8 DATA OUT 9 N C N C 10 GND P Table 8 Pin out for Atmel AT17LVxxx devices In Circuit Programmer Loader User Manual Revision 1 10 Page 22 Appendix A 10 pin connector 7 8 Pin out for Silicon Labs MPU Pin Pin Name Direction Description 1 N C N C 2 N C N C 3 N C N C 4 VCC P 5 N C N C 6 C2CK OUT 7 N C N C 8 C2D IN OUT 9 N C N C 10 GND P Table 9 Pin out for Silicon Labs MPU 7 9 Pin out for Microchip MPU Pin Pin Name Direction Description 1 PGC OUT 2 N C N C 3 PGD B 4 VCC P 5 N C N C 6 N C N C 7 N C N C 8 N C N C 9 MCLR OUT 10 GND P
12. efer to Troubleshooting section for more details In Circuit Programmer Loader User Manual Revision 1 10 Page 16 6 1 6 2 6 3 Troubleshooting Troubleshooting If any problem happened during operation with host PC the error messages will be printed in a status bar Please send the output as well as details about the project to Amfeltec tech support at support amfeltec com Failed to establish connection e Verify that eLoader is connected to host computer Please look Control Panel to verify that host computer recognize eLoader and check what port number assigned to it e Unplug eLoader device and plug it back Check that green LED flashed 3 times e Verify that DIP switch 4 is set to ON position during operation with the host PC Failed to update firmware e Verify that eLoader connection status is Connected in Port Control section on the EasyLoader Update utility main dialog e Verify that firmware filename is original and didn t corrupted Failed to program target device The eLoader supports debugging mode that allows sending debug messages via mini USB connector to the host PC during programming loading operation This mode slow down eLoader operation but at the same time can provide full debug information For this purpose you need to connect eLoader to USB port of any PC Start HyperTerminal application with the following settings Baud rate 230400 bps Data bits 8
13. ents or corrections are greatly valued in our effort for excellence and continued improvement Abbreviation Abbreviation Description eLoader In Circuit Programmer Loader Host application eLoader Update application Revision History In Circuit Programmer Loader User Manual Revision 1 10 Page 1 About this Document Add support for EXAR XRP77xx family Oct 25 2010 Add Open Save project list Add support for TI MSP430 Family Apr 28 2011 In Circuit Programmer Loader User Manual Revision 1 10 Page 2 2 1 General Description General Description Introduction eLoader is designed to provide a flexible and cost effective programming loading solution for electronic device manufacturers as well as for hardware design companies and their customers It allows code upgrades on any JTAG SPI I2C or similar serial interfaces compliant device like FPGA CPLD EEPROM Flash as well as programming different microcontrollers during development testing or production Initially eLoader has to be connected to the host computer via USB port and loaded with the programming information The Windows based software application provides a user friendly interface to eLoader During normal operation eLoader doesn t have to be connected to the host computer It connects to the debug connector on the target board and automatically starts loading programming the target device when power
14. irmware received from Amfeltec Corp and click on Open to start the firmware upgrade 4 If the firmware upgrades succeeded the windows with new firmware version will show up If the firmware upgrade failed please refer to Troubleshooting section or contact Amfeltec Corp tech support Programming Target Device This section describes details during eLoader normal operation In Circuit Programmer Loader User Manual Revision 1 10 Page 15 Operation NOTE Please verify that the DIP switch 4 is set to OFF position This position enables operation with target device When all necessary data is stored in the eLoader you can then program the target device eLoader doesn t require separate power sources It receives power from the target device After the eLoader is connected to the target device via cable applying power to the target device will initiate the programming loading sequence Projects stored in the eLoader will be executed one after another until all target devices are programmed Two led lights red and green will show the current status of the process This is the complete list of available statuses Green LED is blinking and Red LED OFF Program or verification task in progress Green LED OFF and Red LED is blinking Program or verification task failure Sequential Green Red LEDs are blinking Program and verification is complete If any problem happened during programming target device r
15. is command open previously saved project list from the file In Circuit Programmer Loader User Manual Revision 1 10 Page 14 5 1 9 5 1 10 5 2 Operation Save Project Command Save current project list into file Firmware Update Command FW Update eLoader supports field upgrade firmware functionality This option allows updating eLoader internal firmware by customer for bug fixing or adding additional functionality In order to check current firmware version click left top corner of EasyLoader Update software and then click on About EasyLoader The About windows will come up About Easyloader Update Val EasyLoader Update Version 2 0 1 e ee EasyLoader Firmware Version 3 3 Build 4 1 3 Copyright C 2005 2010 Figure 6 EasyLoader Update utility About dialog This feature should be used only if Amfeltec support team requests it The new firmware file has extension eld Please do not modify name of firmware filename In order to upgrade firmware please execute the following steps we assume that eLoader is connected to the host computer and connection status is Connected and DIP switch 4 is set to ON position 1 Copy new firmware file received from Amfeltec Corp into temporary directory 2 Click on FW Upgrade button Software will show the current firmware version and confirm that the operation Click on YES to continue 3 The Open File dialog will ask you for a new firmware file Select new f
16. is turned on The result of the operation is displayed on the two LEDs red and green Figure 1 In Circuit Programmer Loader In Circuit Programmer Loader User Manual Revision 1 10 Page 3 General Description 2 2 How it works eLoader can program load specific device group of the devices connected via the serial interface JTAG DC or SPI or multiple group of the devices JTAG and DC JTAG and SPI JTAG and Microcontroller Each target device requires a separate project to be created The project describes the device in more detail with things such as interface type and the data file to be loaded Designs containing multiple devices will have separate project files describing each device A memory usage bar shows available eLoader resources you ll notice the bar move as more and more projects are added After eLoader is configured it can be disconnected from the host computer to run independently All the configuration data is stored in non volatile memory internally on the eLoader The standard version of eLoader has 16 Mbytes of internal memory and the extended one has 32 Mbytes of internal memory eLoader uses a standard 10 pin 2 row 0 1 inch pitch connector see Appendix B to connect to the target board via cable Cable can be ordered from AMFELTEC Corp or manufactured by the user for example cable connector can used from DigiKey P N CKC10S ND eLoader is taking power from the ta
17. n Connechor sise 19 7 1 Pin out for JTAG interface iii 19 7 2 Pin out for JTAG and DC interfaces su 20 7 8 Pin out for JTAG and SPI interface us 20 ZA Pin out for DC interface iii 21 7 5 Pin out for SPI interface ie 21 7 6 Pin out for Altera FPGA EPCSxxx devices ceccccceeeeeeeeceeeeeeeeeeeeaeeeeaaeseceeeesaeeesaeeeeneeees 22 7 7 Pin out for Atmel AT17LVxxx devices sisi 22 7 8 Pin out for Silicon Labs MPLA 23 7 9 Pin out for Microchip MPLA 23 7 10 Rin o t for EXAR XRP77Xxx Family ssc sister hrs ere era a AAEE Ead aieka 24 7 11 Pin out for TI MSP430 Family iii 24 Appendix B DIP Switch Description ss 26 Appendix C EasyLoader Configurator sus 27 9 1 EasyLoader Custom Configuration Dialog cccccccceeeeeeeeceeeeeeeeeeeeaeeseeeeeseaeeetaeeneneeeed 28 9 2 EasyLoader Export Configuration Command 28 9 8 DC Configuration parameters iii 29 In Circuit Programmer Loader User Manual Revision 1 10 Page ili Conten ts Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 In Circuit Programm r Load r 223ss certes lens aatia andaa aaa ada aaa aa lisse enr lens 3 eloader with target deviCS EE 4 EasyLoader main dialogue mere ege 11 EasyLoader Update main dialog with sample project 12 eLoader project with description 13 EasyLoader Update utility About dialog ss 15 Connector 10 pin to target device ss 19 Multipurpose DIP SWItON 22 428 Minna net daar
18. need to provide in order properly program the device DC Parameter Note Total flash memory size Kbytes Number of bits in a flash address bits Number of address bytes 1 2 3 Flash page size bytes DC control code hex For all EEPROM devices the value must be A DC control code mask hex For all EEPROM devices the value must be F DC control code shift bits For all EEPROM devices the value must be 4 I2C device address hex DC device address mask hex If device address mask is zero device doesn t use any device address bits DC device address shift bits DC upper address bits mask hex DC upper address bits mask in device address DC upper address bits shift bits DC upper address bits shift in device address bits DC I O noactive hex I2C not used byte value hex Clock frequency kHz Clock high time tHigh ns Clock low time tLow ns Start condition hold time tHD_STA ns Start condition setup time tSU_STA ns Data input hold time tHD_DAT ns Data input setup time tSU_DAT ns Stop condition setup time tSU_STO ns Bus free time tBuf ns Write cycle time tWR ms In Circuit Programmer Loader User Manual Revision 1 10 Page 29
19. oader device You will need to use it in order to update and verify contents of eLoader device The installation is simple Execute ELoaderSuiteInstall msi file from CD You can leave all default settings The installation process will copy the necessary files onto your hard drive update registers and create shortcut to executable file Device Driver Installation for eLoader eLoader device requires the USB device driver installation Plug in the eLoader device into a USB port of your host computer e Found New Hardware Wizard dialog will show up e Select Yes and click on Next e Select Install from a list of specific location and click on Next e Type full path to lt EasyLoader directory gt Driver directory click on Next and follow the installation steps Now you can un plug and plug in back eLoader The system should recognize it as AMFELTEC Corp EasyLoader USB device Host system recognizes eLoader device as a Serial device You can detect the COM port number by opening Control Panel System Hardware Device Manager If installation succeeded you will find eLoader device under Ports COM amp LPT section eLoader device must be plugged in You will need to use the COM port number in host application EasyLoader Update In Circuit Programmer Loader User Manual Revision 1 10 Page 6 Configuration Configuration XILINX FPGA CPLD with JTAG interface Target device XILINX FPGA CPLD PROM Interface JTAG TMS TCK
20. rget board so no extra cables are required for powering When eLoader receives power from target board it will start to execute all projects in order by starting from the first one eLoader has two LEDs that show the current device status Cycling RED GREEN LEDs indicated success status after the target board has been programmed loaded and verified A blinking GREEN LED shows that the device in the process of programming or verification A blinking RED LED shows that the program or verification task failed Figure 2 eLoader with target device In Circuit Programmer Loader User Manual Revision 1 10 Page 4 2 3 2 3 1 2 3 2 2 3 3 2 3 4 General Description Application Board Assembly House eLoader can be used in a electronic board assembly house to program the programmable logic devices as they come off the assembly line Do not need any preprogramming After initial configuration the device does not require a computer connection for normal operation This can help completely avoid preprogramming parts first article sign off and as a result significantly reduce production costs It s easy to use so minimal training is required for the personal Update Firmware prior to Shipping Electronics boards can be programmed just prior to shipping to the customer This ensures that only the latest firmware will be used This also adds further flexibility because a board can be programmed with different securit
21. s For more details please refer to troubleshooting section In Circuit Programmer Loader User Manual Revision 1 10 Page 26 Appendix C EasyLoader Configurator Appendix C EasyLoader Configurator EasyLoader configuration utility ELoaderConfig is used to create custom configuration for target device The utility includes in an installation package To start ELoaderConfig click on Start Program Amfeltec EasyLoader X Y Z ELoaderConfig The main dialog will come up Figure 9 d ELoaderConfig Control Target device lt Select Target D Interface Help Static Config file E Figure 9 ELoaderConfig utility main dialog Select Target device and Interface type ELoaderConfig provides configuration only for the parts that needs special configuration file for eLoader For example I2C devices that has different parameters or SPI devices Created by this Utility configuration file has ecfg extension and has interface and timing parameters that specific for target part The configuration utility supports four commands New Open Modify and Save The New command will open sequence of dialogs Error Reference source not found that will ask detail information about target device This information will used later in order to properly program the target device The Open command will read previously created configuration file and will show it in a configuration window The Modify
22. s the EasyLoader s memory capacity will allow Your eLoader project can include some extra information like project description This information is hidden by default If this information exists it will appear as a second line in a project Remove Command Remove This option will allow you to remove a project from the list If you decided to remove the project select the project and click Remove button The project will disappear from the list Clear All Command Clear All Click on Clear All button in order to clear the project list all project created before it will be removed Update Command When all projects are created and you are ready to update eLoader device with a new data please click on Update button The application will start to uploading new data into eLoader The progress bar will show the current status of update Get Info Command This command reads the control information without data of all projects stored in eLoader and displays it in the project window If you decided to add new project simply add new project and click on Update button The application will update eLoader with a new project only Verify Command This command compares the currently created projects with projects that are stored in eLoader You can use this command to verify the contents of you device Get Data Command This command reads all the data of all projects stored in the EasyLoader device Open Project Command Th
23. sise 8 4 6 Silicon Labs MCPU with JTAG interface 00 0 ceeccceeeeeeeeeeeeeeceeeeeeeaeeeeeaeseneeeseaeeesaaeeneneeeeaees 8 4 7 Silicon Labs MCPU with C2 interface iii 8 4 8 Altera FPGA CPLD with JTAG interface us 9 49 EXAR XRP77XX family ist niistne aannaaien aia ankea tas talente ane nest 9 4 10 TI MSP430 family with 2 wire JTAG Spy Bi Wire ccccccescececeseeeeeeeceaeeeaeseaeeeeeeeeeeeereees 9 5 EEN gedieegeg eege eegener gege mn nn nat een 11 5 1 Update EasyLoader device sisi 11 5 1 1 Start EasyLoader Update Utility 11 5 1 2 Establish connection with eLoader 11 In Circuit Programmer Loader User Manual Revision 1 10 Page ii Contents 5 1 3 Project Contents Management 12 5 1 3 1 Add new Project Add 13 5 1 3 2 Remove Command Remove s ssssssssssesseesseesesssererrrsrrsnnsernssrnsee 14 5 1 3 3 Clear All Command Clear AI 14 5 1 4 Update Command zetia session i aa a aai a ataa aaa 14 5 1 5 Get Info Command sisi 14 5 1 6 Verity Command sis sas ae EE EE 14 5 1 7 Get Data Command iii 14 5 1 8 Open Project Command ss 14 5 1 9 Save Project Command su 15 5 1 10 Firmware Update Command FW Update 15 5 2 Programming Target Device 15 PrOUDISSMO OtIING PR UC 17 6 1 Failed to establish connection 17 6 2 Failed to update firmware iii 17 6 3 Failed to program target device 17 Appendix 10 pi
24. tem recognizes eLoader as Serial device From Port Control section select port name COM that connects to eLoader device Press Connect button and EasyLoader Update software will try to establish a connection with the device If connection succeeded the connection status will change to Connected in Port Control section and software will ask you to read contents of the device now If you select YES the software will read and show you the contents see sample contents in Figure 4 Otherwise the project list will stay empty If connection failed to establish the error message will show up Please refer to Troubleshooting section for more details 5 1 3 Project Contents Management EasyLoader Update application uses term of Project to separate different target devices Before you are going to create multiple projects you need to understand where you can use single project and where you need to create multiple projects If you would like to use multiple projects in eLoader device contact Amfeltec support to confirm that the specified target device can be programmed by eLoader device one after another In Circuit Programmer Loader User Manual Revision 1 10 Page 12 5 1 3 1 Add new Project Add Operation This option will allow you to create and add new projects to the eLoader You will be required to provide different information depending on your target device and interface type See Appendix A for more details e Select
25. to NVM Select this option if you are going to program NVM space This option will prevent you from programming NVM space by mistake 410 TI MSP430 family with 2 wire JTAG Spy Bi Wire Target device Select TI MCU Description Current project description Interface Select SpyBiWire Chip Family Select your target device family In Circuit Programmer Loader User Manual Revision 1 10 Page 9 Configuration Device ID Select your target device from selected family Data File Select data file to program A43 file format Erase Select memory segment that required ERASE command NOTE 1 If the data file accesses the memory that was not selected to be erased warning message will display NOTE 2 If data file doesn t access selected memory for erase this memory segment will not be erase optimization Blank Check Enable Blank Check after erase Verify Data Verify data after programming In Circuit Programmer Loader User Manual Revision 1 10 Page 10 5 1 5 1 1 5 1 2 Operation Operation Update EasyLoader device This section explains the details of operation of the eLoader with the host computer during configuration steps NOTE During this step please verify that DIP switch 4 on the eLoader is set to ON position Start EasyLoader Update Utility To start the EasyLoader Update utility click on Start Program Amfeltec EasyLoader EasyLoader
26. y capability settings based on the particular customer order No need to stock boards with different firmware Board assembling can be done with the blank programming parts and firmware or security can be programmed before shipment per order base This solution will decrease inventory and make it not depend of the market Remote Firmware Update Compact size and ease to use make it possible to simply ship eLoader to customers around the world Customer just needs to connect eLoader to the device and to switch power on eLoader starts working after power is turned on so it can be easily operated by anyone No need to send an engineer overseas just to reprogram a customer s device or ship device back to factory for update or for replacement Engineering Because eLoader doesn t need computer for the normal operation it can be very useful portable programming loading solution in case were debugging laboratory and engineering cubes are in the different places It also helps to programming loading different chips via I2C or SPI interface during debugging In Circuit Programmer Loader User Manual Revision 1 10 Page 5 Installation 3 3 2 Installation This paragraph explains in detail the eLoader software installation steps The software package includes EasyLoader Update application and device driver for USB devices Software Installation EasyLoader Update application provides communication between host computer and eL

Download Pdf Manuals

image

Related Search

Related Contents

安全データシート - Santa Cruz Biotechnology  scil SPOTCHEM™ EZ Chemistry Analyzer Operations Manual  A8_La colocation_ mode d`emploi  Étude rétrospective des interactions médicamenteuses  symbioz 324  Prime-Line R 7015 Instructions / Assembly  "user manual"  Philips 42PFL4208D 42" Full HD Smart TV Wi-Fi Black  CF-104_manual [更新済み]  Ayuda - Sindicatura General De La Nación  