1. Port NA Figure 2 9 BERT Parameters Table 2 5 BERT Parameters Parameter Possible Values Remarks Port Main El Main T1 Port Type E1 T1 BERT Pattern 511 2047 2E15 1 QRSS 2E23 1 BERT Error Inject Rate No Error 1 Configuring Inband Loop Parameters Note Inband Loop parameters are available for Main port only gt To set Inband Loop parameters e Configuration gt Port Parameters followed by Inband Loop Param The Inband Loop Parameters dialog box appears Port Level Edit Menu 2 9 Chapter 2 Fault Configuration RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Parameter Port Port Type Inband Loop Pattern Configuration Activate Pattern bin Dectivate Pattern bin 16 1 172 17 152 192 Inband Loop Parameters Port MAIN E1 Port Type Inband Loop Pattern Configuration User Configured Activation Pattern biri b Deactivation Pattern bin b Figure 2 10 Inband Loop Parameters Table 2 6 Inband Loop Parameters Possible Values Notes Main E1 Main T1 E1 T1 RDL Loop User Configured Binary String of up to 8 bits LSB is rightmost bit Only 1 or O digits will be allowed Default 0 This field is enabled only when Pattern Configuration User Configured Binary String of up to 8 bits LSB is rightmost bit Only 1 or O digits will be allowed Default 0 This field
2. Cancel Figure 2 7 Save File Dialog Box gt To print the list Click Print The printer dialog box appears Displaying Self Test Results When powered the FCD LC runs a self test to detect hardware failures and to provide circuit level diagnostics data The Self Test command displays the results of the selected FCD LC self tests gt To display FCD LC self test results Fault gt Self Test The Self Test Results dialog box appears This dialog box lists all possible detectable agent failures and the status of each failure A failure in the parameter is indicated by On No failure detected is indicated by few 4 1 172 17 152 192 Self Test Results System Clock Es SFIFO EPROM eo Get successful N Figure 2 8 Self Test Results 2 8 System Level Agent Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 2 Fault Configuration 2 3 Port Level Edit Menu Configuring BERT Parameters Note BERT parameters are available for Main ports only gt To set BERT Parameters 1 Configuration gt Port Parameters gt BERT Param The BERT Parameters dialog box appears 16 1 172 17 152 192 BERT Parameters Port MAIN E1 Port Type E BERT Pattern SEE gt BERT Error Inject Rate 10E Ho Error TS Selection Mode Ce User Defined TS
3. Aa 11172 17 152 132 TS Assignment x manes Mo 4 B s 7 a s 10 14 2 14 fas 16 faz 18 19 20 21 22 2 24 as 26 27 28129130031 kin Close Refresh Get successful E Used TS Left TS Close Refresh Get successful N Figure 3 12 TS Assignment Window for FCD T1LC Resetting the FCD E1LC FCD T1LC gt To reset the FCD E1LC FCD T1LC 1 Configuration gt Reset Or Click the shortcut key on the toolbar System Level Agent Menu 3 11 Chapter 3 Configuration Management RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual A message box Resetting FCD appears asking for confirmation of the reset 2 Click lt OK gt to confirm operation Configuring the Manager List The Manager List command displays IP addresses of known Network Management Stations to which the FCD LC sends SNMP traps when an alarm occurs To receive an agents traps the management station must type its own IP address in the Manager List The list may contain up to five entries gt To view modify the Manager List 1 Options gt Manager List The Manager List dialog box appears 2 Enter change the IP addresses in the Manager List dialog box by clicking in the addresses field until it s highlighted Enter the new numbers in the address field Use the right and left arrows or mouse to jump to the next field 3 Click lt Set gt to display the updated IP Address in the Manager Lis
4. Possible Values Remarks Function of the selected port NMS Slip NMS PPP Agent Slip Terminal When Usage Terminal Auto 1200 2400 4800 9600 19200 38400 57600 115200 When Usage Terminal 1200 2400 4800 9600 19200 38400 57600 115200 Number of data bits in the vvord format transmitted through the selected port 7 8 Parity mode used by the selected port None Odd Even Type of supervisory port interface DCE for direct connection to supervision terminal DTE for connection through a modem to supervision terminal State of the CTS Clear to Send line in the selected port On CTS is always on RTS CTS line follows the local RTS line Possible Values Remarks Time delay between Data Carrier Detection DCD and the sending of the data if the interface type is DTE 0 10 50 100 200 300 State of the DSR line On DSR line is continuously on DTR DSR line tracks the DTR line On is only applicable if Interface DCE Specifies when callout will be activated Always Upon Link Fail Controls the use of the call out trigger None All Alarms Major Alarms 0 8 Specifies the time FCD LC vvill vvait for an ansvver after each dialing attempt 30 45 60 Selects the dialing mode supported by the telephone netvvork Tone Pulse Specifies if the alternate number will be dialed after the specified number of call attempts on the primary number failed No Yes up to 16 characters up to 16 characters
5. The FCD ETLC FCD T1LC Level window provides a dynamically updated graphical representation of the front and rear panel allowing you to monitor and manage FCD ETLC FCD T1LC operations The view includes port interfaces and their operational and communication status Status Bar The Status Bar indicates if FCD E1LC FCD T1LC is Connected or Disconnected Menu Bar The Edit Agent mode menu bars include any of the follovving pull dovvn menus Configuration Fault Diagnostics Statistics VVindovv Options and Help Menu contents differ between Edit and Agent modes and differ when ports are selected Toolbar The following shortcut keys are available on the toolbar el FCD E1LC FCD T1LC Info Display status and configuration of current FCD ETLC FCD TILC He TS Assignment View the actual timeslot assignments for all ports Poll Agent Causes the NMS to poll the agent Softvvare Configuration access the port configuration dialog box Reset Resets the FCD E1LC FCD T1LC device e l is Agent Edit Modes Tvvo vievvs of the agent are displayed in the FCD ETLC FCD T1LC view vvindovv e The top vievv Fdit Configuration Mode corresponds to a configuration that is stored in the management station In the Edit Configuration mode you can change configuration settings e The bottom view Agent Mode corresponds to the agent unit as a whole and to the current configuration of the selected agent In the Agent mode
6. Figure 3 28 Fthernet Parameters Dialog Box CH 2 Table 3 18 ETH Tab Parameters Parameter Possible Values Remarks Auto Negotiation Enabled Disabled Default Type 10 BASE T Half Duplex 10 BASE T Full Duplex 100 BASE T Half Duplex 100 BASE T Full Duplex Note Enabled only when Auto Negotiation Disabled Flovv Control Back Enabled Disabled Pressure e Note Enabled only when Auto Negotiation Disabled Bridging Mode Filtered Transparent Configuring Callout Destinations Note Callout Destinations are available for the SP port only gt To configure callout destinations 1 Configuration gt Call Out Destinations The Callout Destinations dialog box appears 2 Click a destination and change the IP Address 3 Click lt Set gt Changed entries are colored 3 34 Port Level Agent Menu RADvievv TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 3 Configuration Management 14 1 172 17 152 192 Call Out Destinations i CONTROL DCE SP Destination IP Address ooo lo O 0 0 lo 0 0 lo 0 0 lo O 0 0 Set Cancel Refresh Get successful N Figure 3 29 Callout Destinations Table 3 19 Call Out Destinations Parameters Parameter Possible Values Notes Port CONTROL DCE SP Destination 1to 5 IP Address IP Address of Destination 0 0 0 0 255 255 255 255 Port Level Agent Menu 3 35 Chapter 3 Configuration Management RADview TDM FC
7. appears 15 1 172 17 152 192 Update Figure 3 7 Update Configuration Dialog Box Note In the event that the sanity check found errors the message Sanity Check Errors appears and update cannot be performed Ifthe sanity check failed due to warnings not errors a message box appears indicating that there were warnings The message box has the following options Cancel leave without updating seeing the warnings View Warnings see warnings that were issued during Sanity Check Close close message box without updating the configuration Confirm Update update the configuration with the warnings at any stage Polling the Agent gt To poll the agent e Configuration gt Poll Agent The agent is polled Displaying the Agent View If the Edit Configuration only is displayed on the screen you may open the Agent view if the agent is connected gt To open the agent part of the application window e Window gt Agent View The Agent Configuration appears below the Edit Configuration 3 2 System Level Agent Menu Displaying FCD LC Information gt To display FCD LC information e Configuration gt FCD Info System Level Agent Menu 3 7 Chapter 3 Configuration Management RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Or e Click the shortcut key on the toolbar EN The FCD Information dialog box appears 14 1 172 17 152 192 FED Information a x General IP A
8. Port Level Edit Menu 3 15 Chapter 3 Configuration Management RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Main E1 T1 Sub E1 T1 Port Parameters gt To configure the Main E1 T1 Port Parameters e Configuration gt Port Parameters gt Software Configuration The Port Software Configuration dialog box appears Parameters for the FCD ETLC are shown in Figure 3 17 and Table 3 9 Parameters for the FCD T1LC are shown in Figure 3 18 and Table 3 10 1 1 172 17 152 192 Port Software Configuration X Port MAIN El Line Type E gt Line Code HD Syne com hbang Ma Ott Inband Mng Rate Kbps Idle Code F Rx Gain Short Haul FAI Enable Inband Loop Detection Disabled A Bits BIT 4 BIT 3 BIT 6 BIT 7 BIT a Figure 3 17 Port Software Configuration Parameters Main amp Sub E1 3 16 Port Level Edit Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Parameter Port Port Type Line Type Parameter Line Code Sync Inband Mng Inband Mng Rate Kbps Idle Code hex RX Gain RAI Enable Inband Loop Detection Visible only for MAIN port Chapter 3 Configuration Management Table 3 9 El Port Software Configuration Parameters Possible Values Remarks Main El Sub El El Type of El line implementing the selected circuit The type of circuit affects the number of frames that the circuit can carry E1 CCITT Re
9. you can monitor the configurations and performance of the FCD ETLC FCD T1LC and its ports One mode may be selected at any given time The selected active mode is surrounded by a light blue border gt To display the Agent mode e From the Window menu select Agent View gt To toggle between the Agent mode and the Edit Configuration mode e Click on the hub which is not currently selected Launching RADview FCD E1LC FCD T1LC 1 5 Chapter 1 Introduction RADvievv TDM FCD E1LC FCD T1LC User s Manual Edit Configuration Mode The Edit Configuration mode top is alvvays displayed in the FCD ETLC FCD TTLC Level window The Edit Configuration mode is used to design configuration modifications without interfering with ongoing FCD ETLC FCD T1LC activities Any Edit Configuration can be downloaded to the FCD ETLC FCD T1LC unit The contents of the window Title Bar and Menu Bar depend on the selected view l the Edit Configuration mode is selected the following appears e Window Title The window title identifies the selected mode E Edit the selected configuration 1 to 10 the FCD ETLC FCD T1LC name and its current status Connected or Disconnected t is possible to prepare a configuration vvithout being connected to the agent Window Menu Bar The Edit Configuration mode menu bar includes the Configuration Fault VVindovv and Help pull dovvn menus Menu contents differ vvhen cards or ports are select
10. 152 192 Line Status Get successful E Figure 2 13 Line Status The dialog box lists all possible detectable port failures and the status of each failure The possible failures depend on the type of port The available status options are On Failure exists No failure Running the Diagnostic Tests gt To enter the diagnostic test function e Diagnostics gt Test The Port Tests dialog box appears A sample Port Tests dialog box is shown for a CH 1 port Port Level Agent Menu 2 13 Chapter 2 Fault Configuration RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Fail4 11172 17 152 192 Port Tests 7 xj Port MAIN El o Port Type El Running Test Status Stop Tests Start Tests Local m Remote BERT m m Tx Inbarid Rx Inband Apply Cancel Refresh Get successful N Figure 2 14 Port Tests Agent CH 1 The Port Tests dialog box contains the port and port type identification at the top and tvvo main functional sections Status and Activate Table 2 8 Port Tests Parameter Possible Values Remarks Port Selected port MAIN E1 MAIN T1 SUB ET SUB T1 CH 1 CH 2 Port Type Type of port E1 T1 HS The Status section shows the current testing status at the selected port In addition you can stop a currently running test e The Tests column lists the possible tests for the selected port and the status of
11. 2 Click lt OK gt to continue If the sanity check detects errors or warning situations the Sanity Check Errors List and or Warning List appears on the screen Errors appear first in the list followed by warnings If necessary click the scroll bar and scroll arrows to view the additional entries System Level Edit Menu 2 1 Chapter 2 Fault Configuration RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual zi lE 11172 17 152 192 Sanity Check Error List 2lERROR 0027 INVALID FALLBACK CLOCK SOURCE Print Save to File Close Ready N Figure 2 1 Sanity Check Error List 2 2 System Level Agent Menu Masking Alarms The Mask command displays a list of active unmasked alarms for the selected FCD LC including system agent and port alarms Note Masking active alarms will also mask them from the History Log gt To view all active FCD LC alarms 1 Fault gt Alarms gt Mask The Mask System Alarms dialog box appears 2 Select the alarms you want to mask and click lt Set gt 2 2 System Level Agent Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 2 Fault Configuration fea 4 1 172 17 152 230 Mask System Alarms X at r Alarm Butter Overflow NIT Switch ON Clock Fallback Clock Internal Clock Master Dial Out Cycle Failed DE Checksum PSVY Swich ON DEF_PAR Switch OM Dial Cut Primary Call Failed Dial Out
12. 2 fault management edit mode 1 2 performance monitoring agent mode 1 4 performance monitoring edit mode 1 4 System Level configuration management edit mode 1 3 Timeslot Assignment configuring 4 3 6 5 displaying 14 3 Toolbar 6 1 Updating downloading the configuration to the agent 8 3 7 5
13. 2 masking port level 12 2 masking system level 2 2 port active displaying 13 2 system level displaying 4 2 f BER test performing 17 2 BERT counters 17 2 BERT parameters configuring 9 2 viewing 17 2 pe Callout destinations configuring 47 3 CGA 25 3 40 3 CH 1 CH 2 configuring port parameters 29 3 displaying port parameters 45 3 Clearing FCD agent alarms 5 2 Configuration management port level agent mode 32 3 port level edit mode 17 3 system level agent mode 10 3 Configuration Management system level edit mode 1 3 Configuring BERT parameters 9 2 Configuring FCD LC Information 1 3 Configuring inband loop parameters 10 2 Configuring timeslot assignment 4 3 6 5 Control port configuring port parameters 18 3 Control Port displaying port parameters 33 3 Current data table and graph displaying 5 4 D Diagnostic tests running 15 2 Edit Configuration Mode 7 1 Edit mode operations port level 12 1 system level 10 1 E Fault management port level agent mode 12 2 port level edit mode 9 2 system level agent mode 2 2 system level edit mode 1 2 FCD LC nformation configuring 1 3 displaying 10 3 FDL Rx messages 9 4 Graphical user interface 6 1 H History log displaying 6 2 Inband loop parameters configuring 10 2 Interval table and graph 7 4 LEDs 9 1 Main amp Sub E1 T1 port configuring port parameters 21
14. 3 displaying port parameters 36 3 Manager list configuring 16 3 Masking alarms port level 12 2 Index system level 2 2 Menu bar 6 1 Mode Agent 7 1 Edit 7 1 0 OOS 25 3 41 3 OOS Signal 25 3 41 3 pe Performance monitoring port level agent mode 3 4 system level agent mode 1 4 system level edit mode 1 4 Polling polling the agent 1 4 selecting polling interval 4 4 9 4 Polling the Agent 9 3 Port failures displaying 14 2 Port information displaying 32 3 Port level agent mode operations 14 1 configuration management agent mode 32 3 configuration management edit mode 17 3 edit mode operations 12 1 fault management agent mode 12 2 fault management edit mode 9 2 performance monitoring agent mode 3 4 Port parameters configuring CH1 CH 2 29 3 configuring Control port 18 3 configuring Main amp Sub E1 T1 port 21 3 displaying CH1 CH 2 45 3 displaying Main amp Sub E1 T1 port 36 3 RADvievv TDM FCD E1L FCD T1L Installation and Operation Manual Port prameters displaying Control Port 33 3 R Reading uploading the agent configuration 8 3 Resetting the device 15 3 Running diagnostic tests 15 2 Sanity check errors viewing 1 2 Self Test displaying results 8 2 Status bar 6 1 System Information displaying 2 3 System level agent mode operations 11 1 configuration management agent mode 10 3 edit mode operations 10 1 fault management agent mode 2
15. Agent Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 3 Configuration Management Note Parameter Rate Kbps Clock Mode FIFO Size bit CTS Clock Polarity RTS State Ce TE WA a Port Port Type Rate Kbps 1 xb4 Clock Mode FIFO Size bit Auto CTS lon Clock Polarity Normal RTS State Mot Active Close Refresh Get successful E Figure 3 27 Port Software Configuration Dialog Box CH 1 CH 2 configuration parameters are the same as for CH 1 with the only difference that there is no Inband Loop Detection parameter Table 3 17 CH 1 CH 2 Parameters HS Tab Possible Values Remarks nX56 nX64 0x64 Line Type Unframed The clock mode DCE DTE1 DTE2 The available options depend on the Clock Mode Auto 16 30 52 72 On RTS NA Normal Invert for HS ports Normal for Ethernet ports State of the RTS Request to Send line in the selected port Not Active Active If an Ethernet port is installed instead of CH 2 you can view its parameters under the Ethernet tab Port Level Agent Menu 3 33 Chapter 3 Configuration Management RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Auto Enabled Default Type E 00 BASE T Full Duplex How Control Back Pressure Enabled Bridging Mode Close Refresh 6 et successful N
16. Manager List Manager List Options See Configuring the Manager List m Manager List 1 5 Port Level Operations Note Port level operations are available only when a port is selected in focus Table 1 4 lists the port level management options for FCD ETLC FCD T1LC available in the Edit mode Table 1 4 Port Level Management Options Edit Mode Tasks Configuration Dialog Box and Parameter Location Path Software Configuration Port Software Configuration dialog box Configuration Main ET Main T1 CH 1 See Configuring Port Parameters m Port Parameters CH 2 SP m Software Configuration Configuring BERT BERT Parameters dialog box Configuration Parameters See Configuring BERT Parameters m Port Parameters BERT Param Configuring Inband Loop Inband Loop Parameters dialog box Configuration Parameters See Configuring Inband Loop Parameters m Port Parameters m lnband Loop Param Configuring User User Information dialog box Configuration Information See Configuring User Information m User Info Note Port level operations are available only when a port is selected in focus Table 1 5 lists the port level management options for FCD E1LC FCD T1LC available in the Agent mode 1 10 Port Level Operations RADview TDM FCD E1LC FCD T1LC User s Manual Tasks Fault CH and E1 T1 only Mask Alarms List all alarms Clear alarms Displaying E1 Link Status Tasks Configuration Displaying
17. Parameters HS Tab Parameter Possible Values Remarks Rate Kbps nx64 nx54 where n value selected in TS Assignment Note For Main E1 or T1 link with Line Type Unframed Rate 0x64 Clock Mode The clock mode DCE DTE1 DTE2 Note 1 When mode Unframed Clock Mode cannot be DTE2 2 If the Ethernet interface is IR IP or IR ETH QN Clock Mode can be only DCE FIFO Size bit The available options depend on the Clock Mode Auto 16 30 52 72 for DTE2 mode Auto for DCE and DTE1 modes CTS On RTS NA Note l the Ethernet interface is IR IP or IR ETH QN Clock Mode is always NA Clock Polarity Normal Invert for HS ports Normal for Ethernet ports Auto Negotiation Enabled Default Type 100 BASE T Full Duplex Fov Control Back Pressure Enabled Transparent Figure 3 21 Port Software Configuration Dialog Box CH 2 Ethernet Tab 3 22 Port Level Edit Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 3 Configuration Management Parameter Auto Negotiation Default Type Flovv Dontrol Back Pressure Bridging Mode Table 3 12 CH 2 Port Software Configuration Parameters Ethernet Tab Possible Values Remarks Enabled Disabled 10BaseT Half Duplex 10BaseT FullDuplex 100BaseT Half Duplex 100BaseT Full Duplex Enabled Disabled Note Field is enabled only when Auto Negotiation is Disabled Filtered Transparent 3 4 Port Level Agent Menu Displaying
18. Port nformation Displaying Port Configuration for SP E1 T1 CH Configuring Callout Destinations for SP only Bert Counters Inband Loop Parameters Tasks Diagnostics for CH and E1 T1 only Running Diagnostic Tests BERT Counters CH1 only Tasks Statistics for E1 T1 only Set Polling interval Dialog Box and Parameter Location Port Mask Alarms See Masking Port Alarms Port Active Alarm List See Displaying Port Active Alarms List See Clearing the Alarm Buffer Line Status See Displaying Port Failures Dialog Box and Parameter Location Port nformation dialog box See Displaying Port Information System Information dialog box See Displaying Port Configuration Call Out Destinations dialog box See Configuring Callout Destinations Bert Counters dialog box See BERT Counters Inband Loop Parameters dialog box See Configuring Inband Loop Parameters Dialog Box and Parameter Location Port Tests dialog box See Running the Diagnostic Tests BERT Counters dialog box See BERT Counters Dialog Box and Parameter Location Polling Interval E1 T1 Agent See Polling Interval Chapter 1 Introduction Table 1 5 Port Level Management Options Agent Mode Path Fault m Alarms Mask Fault Alarms m l ist Fault Alarms m Clear Fault m l ine Status Path Configuration m Port Parameters Port Information Configuration
19. Port Parameters m Softvvare Configuration Configuration m Port Parameters m Call Out Destinations Configuration gt BERT Param Configuration m lnband Loop Param Path Diagnostics est Diagnostics BERT Counters Path Statistics Port Performance m Polling Interval Port Level Operations 1 11 Chapter 1 Introduction RADview TDM FCD E1LC FCD T1LC User s Manual Table 1 5 Port Level Management Options Agent Mode Cont View Current Data table and graph View Interval Data table and graph Resettng Statistics Viewing FDL Rx messages FCD T1LC only 1 12 Current Data See Displaying Current Data Table and Graph Interval Data See Displaying Interval Table and Graph See Reset Statisitics FDL Rx Message dialog box see Displaying FDL Rx Messages FCD T1LC only Port Level Operations Statistics Port Performance Current Data Statistics w gt Port Parameters m lnterval Data Statistics Port Performance Reset Statistics Statistics FDL Message kx Chapter 2 Fault Configuration 2 1 System Level Edit Menu Vievving Sanity Check Errors gt To view the results of the last agent sanity check 1 Fault gt Sanity Check Frrors If the Edit Configuration does not contain error s or warning s the message No Sanity Errors appears ck Error Ed IF 11172 17 152 230 Sanity Che Pa Q NO SANITY ERRORS Ic 4
20. The RADview solutions conform to ITU T Telecommunication Management Network TMN recommendations for SNMP management systems known as the FCAPS model Fault management detects and correlates fault in network devices isolates faults and initiates recovery actions e Configuration management tracks configuration changes configures installs and distributes software and configuration files across the network Accounting management collects accounting data and generates network usage reports Performance management continuously monitors network performance QoS CoS and resource allocation Security management controls and restricts access to network resources 1 2 Brief Description of the FCD E1LC and FCD T1LC devices The FCD E1LC and FCD T1LC are managed single or dual port access units for business applications that integrate voice and data traffic over El 2 048 Mbps T1 1 544 Mbps and fractional E1 T1 services FCD E1LC FCD T1LC can be used as a rate and interface converter or as an integrating E1 T1 multiplexer for Fractional E1 T1 services Data port rates for FCD ETLC are selectable for any multiple of 64 kbps up to 2048 kbps Data port rates for FCD T1LC are selectable for any multiple of 64 kbps up to 1536 kbps User data of each port is placed into an E1 T1 frame using only the required number of timeslots FCD ETLC FCD T1LC is available in a single and dual channel versions In this m
21. from the agent 1 Configuration gt Read The message Reading operation will replace Edit Configuration appears 2 Click lt OK gt to confirm the operation fea E 1 172 17 152 192 Read Reading operation will replace Edit Configuration Cancel Abort EEE ES Se eee Figure 3 6 Read Configuration Message Updating Downloading the Configuration to the Agent After editing the FCD E1LC FCD T1LC configuration you can download the information to the FCD LC Agent Notes Update is available only when there is communication with the agent f tests are currently active except Rx Inband FCD LC sends the following message UPDATE CANNOT BE PERFORMED Stop tests gt To download configuration modifications to the agent 1 Configuration gt Update The system will perform a Sanity Check and if passed the Update Configuration Window appears displaying the message Update operation will replace Agent s configuration 2 Click lt OK gt to confirm Update 3 6 System Level Edit Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 3 Configuration Management The new configuration is immediately downloaded to the FCD LC Note If communication problems occur during the update process the message Timeout Update result was not received appears If tests are running the message Update cannot be performed Stop Tests s
22. gt FDL Message gt Rx The Port FDL Rx Message dialog box appears 4 8 Port Agent Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Parameter Port Port Type SAPI TEI Control Report FCS Status Time Interpretation Port Type SAFI 14 0 0 TEI OEA 1 FCS Status GOOD Control Time 90 Report 00 01 00 00 00 03 00 z T 1 T 3 Chapter 4 Performance Monitoring Figure 4 8 FDL Rx Message Dialog Box Table 3 5 Port FDL Rx Message Possible Values Remarks Main T1 Sub T1 T1 Service Access Point Identifier Terminal End Point Identifier One byte 00 through FF Eight bytes that carry the message contents Indicates whether the FCS Frame Check Sequence message is Good or Bad message probably contains an error Time when the message was received at the management terminal HH MM SS where HH hours MM minutes SS seconds Port Agent Menu 4 9 Chapter 4 Performance Monitoring RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Parameter CRC Error SE Event FE Event LV Event SL Event Loopback Reserved Counter Table 4 5 Port FDL Rx Message Cont Possible Values Remarks The following fields contain the contents of the four latest FDL messages T T 1 T 2 T 3 Number of CRC errors specified in one of the following ranges None 1 5 5 10 10 100 100 319 320 or more Severely errorr
23. the appropriate channel Click lt OK gt to close the message box and change the FIFO Size of the problematic CH to a matching value Ifthe new data overwrites the existing connections the latter will be disconnected If you defined too many timeslots to be connected the following message box will be displayed No of TS is too big Max possible TSs will be connected When you click OK only timeslots with numbers higher that Start TS will be connected Disconnecting TS Connections To disconnect a TS connection in a cell Click the connected cell and click lt Disconnect gt The TSs cell becomes gray System Level Edit Menu 3 5 Chapter 3 Configuration Management RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Reset All gt To reset all TS connections on the grid 1 Ensure that no TS connection cell is selected 2 Click lt Reset The message Removing TS connections appears 3 Click lt OK gt to continue All existing TS connections in the port are deleted Reading Uploading the Agent Configuration The Read command allows you to upload the current FCD LC agent configuration to the Edit Configuration After the Read operation the Edit Configuration is identical to the Agent Configuration The uploaded configuration is automatically stored in the management station Note Read will be enabled only if there is communication with the agent gt To upload the configuration
24. 004 01 00 00 00 00 21 MAIN E1 SIGNAL LOSS Major 2004 01 1 00 00 07 Print Save to File Clear Close Refresh Ready Iw Figure 2 6 Alarm Buffer List The Alarm Buffer List displays all the unmasked recorded alarms from system card and port levels since the last time the log was recorded If the list is long you can click the scroll bar or scroll arrows to display more entries Table 2 4 Alarm Buffer List Parameter Possible Values Remarks Code Code which indicates a certain alarm description Port Port number in which the alarm originated This parameter is applicable only for port alarms Description Description of the alarm Status The status of the alarm Major Minor Off Date Date when the alarm occurred Time Time when the alarm occurred gt To clear all the alarms from FCD LC alarm buffer Fault gt History Log gt Clear OR e Click Clear The system does not request confirmation for this operation gt To save the list 1 Click Save to File gt The Save File Dialog Box appears System Level Agent Menu 2 7 Chapter 2 Fault Configuration RADvievv TDM FCD E1LC FCD T1LC Installation and Operation Manual 2 Enter filename and select type of file PDF or HTML 3 Select location to save the file and click lt Save gt My Recent D Desktop Documents er Le Computer ee hiy Network File name save Files of type Acrobat pdf
25. 1LC Installation and Operation Manual CGA OOS Signal OOS hex SA Bits Bit 4 Bit 5 Bit 6 Bit 7 Bit 8 Note 3 18 Table 3 9 E1 Port Software Configuration Parameters Cont Method used to signal the carrier group alarm CGA state to the other end of the selected link None Non transparent mode When one of the links is in out of service state the time slots carry the appropriate out of service code data voice OOS to the other end of the link Trans When one of the links is in out of service state the time slots carry the appropriate OOS code to the other end of the link Signaling bits A and B are not forced into the OOS state Full Fully transparent mode When one of the links is in out of service state the state of the time slots and the state of the signaling bits does not change State of the signaling bits when the link is in out of service OOS state Forced Idle Signaling bits A and B are idle when the link is in out of service state In addition if the line type is ESF signaling bits C and D are also idle Forced Busy Signaling bits A and B are busy when the link is in out of service state In addition if the line type is ESF signaling bits C and D are also busy Busy Idle Signaling bits A and B are busy for 2 5 seconds then become idle until the out of service state ends In addition if the line type is ESF signaling bits C and D are idle for 2 5 seconds before switching to busy state Id
26. 222 Mask System Alarms Dialog BOX mitad loto 2 3 Ss PAN AMS cr eee T 2 4 A R o E de 2 5 Ss e neia a den 2 6 DO eege 2 7 De CIMAS DORA 2 8 A ee er eee 2 9 KA E E e C RS aa 2 10 RADvievv TDM FCD E1L FCD T1L Installation and Operation Manual Table of Contents obana Loop Parameters mmmmmmmrm m mm mm mm mmm mrm m mmrmmmrmmrmrmrmrmrmrmrmrmrmrmmmmmmmmmmm mmmmm mmmmmmmmmmiu 2 11 212 PO Mas OLE E 2 12 2 13 Port Mask Alarms for FC aaa da ya anlaya alay 2 13 27 TL h nd 2 14 m 2 15 2510 POR Tesis En 1 b 2 16 7 OUN CRISE ll ala elf 2 18 BERT Pole io mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmki 2 18 OO 0 00 000 3 1 An ii ii b b n 3 2 aa 3 3 A aaa anas n 3 3 7 COUP C OnE ON ee 3 5 3 0 Read Configuration Message a oo rte 3 6 3 7 Update Configuration Dialog OR rieniras 3 7 30 PEO LON b 3 8 OO 3 10 SO SR D II anio 3 11 3 11 TS Assignment Window for 1 See 3 12 3 12 TS Assignment Window for FCD TTL ie 3 12 n m 3 13 3 14 CONTROL DCE Port Ee E a 3 14 CONTROL DEE Port Conliguration DP 3 15 3 16 Port Software Configuration Parameters Main ET 3 17 3 17 Port Software Configuration Parameters Main T1 3 19 3 18 Port Software Configuration Dialo
27. 3 M 5 s Me s r ra is is 17 ra 20 21 22 23 124 25 26 27 28 20 30 1 super fo fo bi TTT fot PE EE EE EE ET LLLLLLL OL LLLLLLLLL en ITIITI ANN CTET TETTETETT Set Cancel Shoup Data Vote Meconnect Reset Al Figure 5 6 TS Assignment for FCD ETLC Updating Downloading the Configuration to the Agent After editing the FCD LC configuration you can download the information to the FCD LC Agent Notes Update is available only when there is communication with the agent e f tests are currently active except Rx Inband FCD LC sends the following message UPDATE CANNOT BE PERFORMED Stop tests gt To download configuration modifications to the agent 1 From the Configuration menu select Update The system will perform a Sanity Check and if passed the Update Configuration Window appears displaying the message Update operation will replace Agent s configuration 2 Click lt OK gt to confirm Update The new configuration is immediately downloaded to the FCD LC 5 6 Configuring TDM Parameters Index A Agent configuration dovvnloading 8 3 7 5 uploading 8 3 Agent Mode 7 1 Agent mode operations port level 14 1 system level 11 1 Agent View displaying 9 3 17 3 Alarm buffer list port level 13 2 system level 6 2 Alarm reports defining scope of 6 2 Alarms all active displaying 3 2 FCD agent clearing 5
28. 505577550 0770000 S 3 2 BaF a A e o E E E 3 10 bu Ma A A 3 11 3 6 User Information Parameters SP wasscsesvecassaptnnnarvenwsaaunnversnestwinadzorasnoeesanteraanepsasamreieacennaecnss 3 13 3 7 CONTROL DCE Port Configuration Parameters 5 3 15 3 8 E1 Port Software Configuration 3 17 3 9 T1 Port Software Configuration Parameter EE 3 20 3 10 CH 1 CH 2 Port Configuration Parameters HS Tab 3 23 3 11 CH 2 Port Software Configuration Parameters Ethernet Tab 3 24 3 12 Port Software Configuration Parameters 5 3 26 15 Calor Parmes PROD a 3 27 3 14 E1 Port Software Ee 3 30 3 15 T1 Port Software SEELEN 3 32 3 16 CH 1 CH 2 Parameters HS 3 35 e a 77 7 7 totes 3 36 3 18 Call Out Destinations Parameters ss 3 37 4250 EE 4 4 4 2 ll 4 5 3 3 Port Performance Current Data aa adan n 4 7 3 4 Port Performance Interval Data Additional Parameters sili i l 4 8 4 9 RADvievv TDM FCD E1L FCD T1L Installation and Operation Manual Note Chapter 1 Introduction This chapter provides an overview of the FCD ETLC FCD T1LC devices and the RADview FCD E1LC FCD T1LC user interface 1 1 Overview of RADview FCAPS model RADview provides a complete solution for monitoring and controlling FCD E1LC and FCD T1LC devices
29. 8 Port Software Configuration Parameters Main amp SubT1 Table 3 10 T1 Port Software Configuration Parameters Possible Values Remarks Main T1 Sub T1 11 Type of T1 line implementing the selected circuit The type of circuit affects the number of frames that the circuit can carry ESF Extended Superframe DS1 24 frames per multiframe D4 AT amp T D4 format DS1 12 frames per multiframe Unframed for use when the data being transmitted is unframed Note 1 If the Line Type changed to Unframed clicking lt Set gt triggers a warning that all of FCD LC TS connections will be disconnected and the CH Rate set to O Note 2 If the Line Type is set to Unframed in a single channel FCD T1LC all the MAIN T1 TSs will be connected to this CH If the Line Type is set to Unframed in a dual channel FCD T1LC all the MAIN T1 timeslots will be connected to CH 2 Line mode for selected port CSU DSU Port Level Edit Menu 3 19 Chapter 3 Configuration Management Parameter Line Code Sync TX Gain Mask dB Line Length feet Parameter Inband Mng Inband Mng Rate kbps Idle Code hex Rx Gain RAI Enable Inband Loop Detection 3 20 RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Table 3 10 T1 Port Software Configuration Parameters Cont Possible Values Remarks Line coding method used for zero suppression B7 B7ZS coding lammed Bit zero suppression A pulse is forced in
30. Alternate Call Failed Self Test LA a a WWW Duplicate Mame in Net Sel Cancel Tn EI Figure 2 2 Mask System Alarms Dialog Box Displaying All Active Alarms Parameter Code Port Description Status The List gt All command displays a list of active unmasked alarms for the selected FCD LC including system agent and port alarms To vievv all active FCD LC alarms Fault gt Alarms gt List gt All The FCD All Active Alarm List appears The FCD All Active Alarm List displays active system and port alarms If the list is long you can click the scroll bar or scroll arrovvs to display more entries Table 2 1 FCD LC Active List Possible Values Remarks Code vvhich indicates a certain alarm description Port in vvhich the alarm originated Description of the alarm State of the alarm Minor Mayor System Level Agent Menu 2 3 Chapter 2 Fault Configuration RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual TIE 11172 17 152 192 FCD All Active Alarm List CLOCK WAS CHANGED TO NTEFMAL m El SIGNAL LOSS 25 Main et LOCAL SYNC LOSS Print Save to File Clear Close Refresh Get successful m Figure 2 3 All Alarms Active List Display ng System Level Alarms The List gt System Level command displays a list of active unmasked alarms for the selected FCD LC only gt To view all active FCD LC system level alarms Faul
31. C RADview TDM FCD E1LC FCD T1LC User s Manual Chapter 1 Introduction zi lE 11 172 17 152 192 Connected Configuration Faulk Diagnostics Statistics Window Options Help FCD E1LC SING LOSS gt CA eh S on Te o J 5 4 Li SG J E JI E 5 055 Im e en gx en Es z OG 8 Statistics Window Options Help Configuration Faulk Diagnostics SYNC 1055 TI E ES ei en en cl 5 77 SYNC 1055 HP 1 a 004 09 27 10 11 Figure 1 3 FCD TTLC Edit Configuration in Focus Launching RADview FCD E1LC FCD T1LC Chapter 1 Introduction RADview TDM FCD E1LC FCD T1LC User s Manual 14 1 172 17 152 192 Connected Configuration Fault Diagnostics Statistics Window Options Help FCD E1LC THE LES D E amp E di E ow W SYNE 1055 FED E1LE TAIN SUB cs Wd peca FE o S o S 35 qu gt WM e Z fa J if Configuration Faulk Diagnostics Statistics Window Options Help FCD T1LC a oF 4 DI Gi mni Li ee Za E E 2 LOSS mn o I W Li wy Li Za GE ie E E Eh Ke x 004 09 27 10 11 Figure 1 5 FCD T1LC Agent Configuration in Focus 1 4 Launching RADview FCD E1LC FCD T1LC RADview TDM FCD E1LC FCD T1LC User s Manual Chapter 1 Introduction Using the Graphical User Interface GUI
32. CD T1LC MAIN T1 SUB T1 CH 1 CH 2 System Level Edit Menu 3 1 Chapter 3 Configuration Management RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Noir 1 If Master Fallback Type is Rx Clock AND Selected port is CH AND Line Type IS NOT Unframed configure the CH as Kat gt 0 e Clock Mode 2 2 t is recommended to select CH as Rx Clock for Master Clock rather than for Fallback Clock otherwise a warning is issued upon Update operation Displaying System Information The System Information command enables you to display information about the system gt To display System Information e Configuration gt System Info The System Information dialog box appears DAN fea E 1 172 17 152 192 System Information Description 0 1 102 AM 0043 M 00 01 Marne Reber Contact name of contact person Location location of device Close Figure 3 2 System Information Table 3 2 System Information Parameter Possible Values Notes Description SW and HW versions Name FCD E1LC FCD T1LC Contact User specified Location User specified 3 2 System Level Edit Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 3 Configuration Management Configuring Timeslot Assignment The TS Assignment command allows you to program the routing of timeslots A complete description of the TS assignment function is discussed on the following p
33. D E1LC FCD T1LC Installation and Operation Manual 3 36 Port Level Agent Menu Chapter 4 Performance Monitoring 4 1 System Edit Menu Polling the Agent Polling immediately updates the Agent vievv and Agent statuses Note Polling is enabled only in the Edit Configuration View gt To poll the agent Configuration gt Poll Agent Or e Click the shortcut key on the toolbar el The system polls the agent immediately and updates the parameters accordingly 4 2 System Agent Menu Displaying G 826 Statistics gt To display G 826 current Data e Statistics gt G 826 Data The G 826 Current Data dialog box appears System Agent Menu 4 1 Chapter 4 Performance Monitoring RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual 314 1 172 17 152 230 G 826 Current Data Frames sec Elapsed Time 600010 days 0 12 15 100 000 80000 days 0 12 18 100 000 i Ba Link ata Save amp Reset Close Refresh Figure 4 1 G 826 Current Data Displaying G 826 Current Data Statistics gt To display current link data e Select an entry in the G 826 Current Data list and click Link Data The Link Data dialog box appears Ea 1 Link Current Data Elapsed Time 580 AAA 0 days 0 11 10 11453 sec 670 AR 96 Framesisec Threshold ESs see o 58146 0 000 4 000 SESs see 0 SESR 96 0 000 0 200 BBEs jo BBER 36 0 000 0 020 Threshold is re
34. Data connection is indicated by the letter D in the cell System Level Edit Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 3 Configuration Management gt To connect a group of consecutive TS of the main E1 T1 port to the data channel CH 1 CH 2 Motes Click lt Group gt The follovving dialog box appears 318 1 172 17 152 192 Group Connec Connected Port SUB E1 E Connect Ciall Mo of TS f Start TS Ts Type Data OK Cancel _ S x l Figure 3 5 Group Connection To connect all connectable TSs to the channel select lt All gt All connectable TSs are connected to the channel Their cells become yellow and the Data connections are indicated by the letter D To connect a group of consecutive TS to the data channel select lt Sequence gt In the bottom part of the dialog box define the number of consecutive TS to be connected and the number of the first TS to be connected The cells of the defined TS become yellow and the Data connections are indicated by the letter D l 1516 selected for management is within the sequence it will be skipped If the rate set for any of the channels does not match its FIFO Size selected in Port Info gt SW Configuration a warning message box is displayed for
35. LC FCD T1LC Installation and Operation Manual Chapter 2 Fault Configuration 14 1 BERT Polling Interval xi Port MAIN E1 Polling Interval sec NN Set Cancel Figure 2 16 BERT Polling Interval gt To set BERT TSs 1 Click lt BERT TS gt The BERT TSs dialog box appears Figure 2 17 2 Check the desired TSs 3 Click lt Close gt GIE 172 17 152 192 BERT T55 ee L A MA a d m A MA ma Figure 2 17 BERT 155 Port Level Agent Menu 2 17 Chapter 2 Fault Configuration RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual 2 18 Port Level Agent Menu Chapter 3 Configuration Management 3 1 System Level Edit Menu Configuring FCD LC information Parameter Type gt To set FCD LC information Configuration gt FCD Info The FCD LC Information dialog box appears 172 17 152 192 FED Information Type FCD ETLC Master Clock Source Fallback Clock Source Figure 3 1 FCD Information Table 3 1 FCD Information Parameters Possible Values Notes FCD E1LC FCD T1LC Master Clock Source Type Port Internal Rx Clock For FCD ETLC NA MAIN E1 SUB E1 CH 1 CH 2 For FCD T1LC NA MAIN T1 SUB T1 CH 1 CH 2 Note This field is relevant only when Type Rx Clock Fallback Clock Source Type Port None Rx Clock Note If Master Clock Source Type Internal the Type None For FCD E1LC MAIN E1 SUB E1 CH 1 CH 2 For F
36. Port Information The Information command displays hardvvare configuration information and status data of the selected port To display port Information e Configuration gt Port Parameters gt Information The Port Information dialog box appears The information displayed is read only and differs for each port type fag 4 1 172 17 152 192 Port Information xj Port SUB El Port Type El Active Status Offline Test Status Off Alarm Status Major Interface Number 1113 Interface Type BALANCE Refresh Get successful m Figure 3 22 Sample Port Information Port Level Agent Menu 3 23 Chapter 3 Configuration Management RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Displaying Port Configuration Control Port Configuration gt To view Control Port Configuration Parameter Usage Rate bps Data Bits Parity Interface CTS Configuration gt Port Parameters gt Software Configuration gt SP tab fea 4 1 172 17 152 192 Port Software Configi EE Port CONTROL DCE Usage NME Slip Rate bh 13200 Data Bits D Parity Mone Interface DCE ETS RTS DCD Delay msec 0 DSR On Close Refresh Get successful UCU Im Figure 3 23 Port Softvvare Configuration Dialog Box SP Table 3 13 Port Softvvare Configuration Parameters SP Possible Values Remarks Function of the selected port NMS Sli
37. RADview TDM Element Management System for TDM Applications FCD E1LC FCD T1LC 1994 2004 RAD Data Communications Publication 357 626 11 04 Contents Chapter 1 Introduction 1 1 Overview of RADView FCAPS model 1 1 1 2 Brief Description of the FCD E1LC and FCD T1LC 5 1 1 1 3 Launching RADview FCD ETLC 1 1 2 Opening the FCD ETLC FCD T1LC View Window ss 1 2 Using the Graphical User Interface 1 6 A E o ate chet eget li ER ibn 1 6 TA 7 EH 00 000 0 1 14 Chapter 2 Fault Configuration EE E ET 2 1 Viewing lli Check EIOS m ya ASE 2 1 2 2 System Level Agent Mei da aaa ai 2 2 116 A AAO see ii 2 2 Displaying All Active Pa aaa aaa aaa 2 3 DLE nl prin obas g m 2 4 Clearing FCD cum r n n sl 2 5 Defining Scope a 2 5 DEA aida cito y EOG S s 2 6 0002 Sel DT a ia 2 8 Ee WOM evel e MENO a a 2 9 Sa E E E A 239 Conu Inband Loop Paramete m a a asa 2 9 275 li anana 2 11 1117 PP a aaa a as 2 11 An e o en 2 14 Displaying Port Pale Susaeta 2 14 b l RTE e 2 15 E ele 2 16 Chapter 3 Configuration Management Ded CN OV ECM eE a 3 1 Contigurine FCO IO du Ee 3 1 Displayine System H D HE Ole S o aos 3 2 Configuring Menen TE EE 3 3 Reading Uploading the Agent Configuration ss 3 6 Updating Downloading the Configuration to the Agent iii iL l 3 7 Pol
38. T Port gt To configure the Sub E1 Port Parameters 1 Select the Sub E1 Port 2 From the Configuration menu select Port Parameters followed by Software Configuration The Port Software Configuration dialog box appears Figure 5 5 3 Set Line Type E1 4 Click lt Set gt 5 4 Configuring TDM Parameters RADvievv TDM FCD E1LC FCD T1LC Installation and Operation ManualChapter 5 Configuring a Typical Application zi F 11 172 17 152 132 Port Software Configuration HE Line Type Line Code yc hbang Wing Inband Wing Rate Kbps NA ldle Code Rx Gain Long Haul FAI Enable 2056 1 Mone Gus Signal Forced Idle Os Hex T Bits BIT 4 BIT 5 EIT 6 BIT 7 EIT 5 Figure 5 5 Port Software Configuration Parameters Sub E1 Port Configuring Timeslot Assignment The TS Assignment command allows you to program the routing of timeslots The FCD LC allows you to program the routing of the individual timeslots gt To configure TS Assignments 1 From the Configuration menu select TS Assignment Or Configuring TDM Parameters 5 5 Chapter 5 Configuring a Typical ApplicationRADvievv TDM FCD E1LC FCD T1LC Installation and Operation Manual 2 Click the TS button on the toolbar The TS Assignment window appears Figure 5 6 3 Select desired time slots and assign type Data or Voice 4 Click lt Set gt IE 11 172 17 152 142 TS Assignment manes 1 2
39. T1LC Installation and Operation Manual Table 3 3 Port Performance Current Data Possible Values Remarks Main E1 Main T1 Sub E1 Sub T1 E1 T1 Group of data fields which describe the amount of time that error s exist s in the current measurement interval Each interval is 15 minutes Number of seconds since the beginning of the current interval 0 899 Number of seconds in the current interval in vvhich an event or alarm occurred 0 899 Number of seconds in the current interval in vvhich at least 320 CRC events or one OOF event occurred 0 899 Possible Values Remarks Number of seconds in the current interval in vvhich a failed signal state exists A failed signal state occurs after 10 consecutive severe errored seconds This state is cleared only after FCD LC processes 10 consecutive seconds of data without an SES 0 899 Number of seconds in the current interval in which at least one controlled SLIP event occurred 0 899 Number of seconds in the current interval in which 2 319 CRC events occurred 0 899 Number of minutes in the current interval in which the bit error rate BER exceeded 1x10 0 899 Number of seconds in which one or more Line Code Violation events were detected 0 899 Number of seconds with 320 or more OOF events or one or more AIS event 0 899 1 96 Displaying Interval Table and Graph gt To display the Interval Table and Graph e Statistics gt Port Performance followed by Int
40. ages Timeslot Routing The FCD E1LC FCD T1LC allows you to program the routing of the individual timeslots gt To configure TS Assignments Configuration gt TS Assignment Or Click the TS button on the toolbar The TS Assignment window appears EzilF 11 172 17 152 192 TS Assignment manes lo 4 llo 7 8 s 12 fas ta fas 16 17 18 9 120 21 22 23 23 25 26 27 2829130031 ben TIET LLLLLLLLDLLLLLLLLLLLL 0 EEE PP PRE PPT Set Cancel Group Eata nice Disconnect Reset All Ready N Figure 3 3 TS Assignment for FCD ETLC fea E 1 172 177 152 192 TS Assignment MAIN T1 Ming TS SUB T1 Mng TS Used TS Left TS man mifa 2 lla ls 6709 ra 14 15 1617 18 19 120 121 122 123 124 ssl tet illiill E 01 nt oT TTT EP EE ETE EEE EEE aa aaa Cancel Group Voice Disconnect Reset All ead Figure 3 4 TS Assignment for FCD T1LC System Level Edit Menu 3 3 Chapter 3 Configuration Management 3 4 RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual A rectangular grid displays the timeslot assignments There are 31 timeslots for FCD ETLC and 24 timeslots for FCD T1LC Each row and each column represents the possible connections of a specific port Colors letters and guides indicate information about the timeslots and ports represented in the grid Their meanings are described in the follov
41. anual the generic term CH is used when the information is applicable both to CH 1 and CH 2 as well as to a single channel version When information is applicable to a specific channel CH 1 or CH 2 this will be explicitly specified Brief Description of the FCD E1LC and FCD T1LC devices 1 1 Chapter 1 Introduction RADview TDM FCD E1LC FCD T1LC User s Manual 1 3 Launching RADview FCD E1LC FCD T1LC Opening the FCD E1LC FCD T1LC View Window nislalfa l l elele A TDM Unit Vievv vvindovv exists for each unit node on the map SNMPc Server WorkGroup Edition IFCD E1L1 dia File Edit View Insert Manage Tools Config Window Help du mb t fas Oy 172 17 155 211v2 liiPhys ddress 3 For Help press 1 Em 172 17 152 227 2 FCD E1L IAD M LA 104 IMXi m Irs 143 172 17 152 124 152 172 17 152 160 172 17 152 163 172 17 152 182 172 17 152 227 172 17 152 227 122 D ss 172 17 152 31 6 172 17 152 46 172 17 152 80 172 17 153 68 172 17 155 80 172 17 157 111 172 17 157 111 112 172 17 157 50 AT 172 17 157 54 172 17 157 58 172 17 150 29 Administrator Supervisor Figure 1 1 FCD E1 T1 LC Devices on SNMP gt To open the FCD ETLC FCD T1LC window Double click on an FCD ETLC FCD T1LC icon in the net map The FCD ETLC FCD T1LC Edit Configuration Mode appears Launching RADview FCD E1LC FCD T1 L
42. ate Payload Loop Received signal at this port is looped through the DXC The signal is typically looped back for transmission after passing through the agent s framing function Line Loop Received signal at this port does not go through the agent minimum penetration but is looped back out Other Loop Any loopback on the selected port that is undefined by the port s configuration Type of signaling transfer mode used by the selected card None Bit Oriented Source of the card s transmit clock Loop Timing Recovered receive clock is the transmit clock Local Timing Local clock source is the transmit clock Through Timing Receive clock recovered from another port is used as the transmit clock of the selected port Reduces the time required for the E1 port to return to normal operation after local loss of synchronization TR 62411 Complies with AT amp T TR 62411 after 10 seconds CCITT Complies with CCITT Rec G 732 Fast after 1 second Identifier of the inband management of the selected link Off FDL or TSO Dedicated FR 3 28 Port Level Agent Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Parameter Inband Mng Rate Kbps Idle Code hex RX Gain RAI Enable Inband Loop Detection Visible only for MAIN port CGA OOS Signal OOS hex Inband Mng Rate Kbps SA Bits Chapter 3 Configuration Management Table 3 15 E1 Port Software Configuration Parameters Con
43. ation Manual Chapter 3 Configuration Management FallA 11172 17 152 192 Port Software Configuration Figure 3 25 Port Software Configuration Parameters Main El Port Level Agent Menu 3 27 Chapter 3 Configuration Management RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Parameter Port Port Type Line Type Line Code Loopback Config Signal Mode Tx Clock Source Sync Inband Mng Table 3 15 ET Port Software Configuration Parameters Possible Values Remarks Main E1 El Type of El line implementing the selected circuit The type of circuit affects the number of frames that the circuit can carry El CCITT Rec G 704 Table 4a E1 CRC CCITT Rec G 704 Table 4b E1 MF CCITT Rec G 704 Table 4a with TS16 multiframing enabled E1 CRC MF CCITT Rec G 704 Table 4b with TS16 multiframing enabled Unframed for use when the data being transmitted is unframed Note 1 If the Line Type changed to Unframed clicking lt Set gt triggers a warning that all of FCD LC TS connections will be disconnected and the Rate set to 0 Note 2 If the Line Type is set to Unframed in a single channel FCD ETLC all the MAIN El 55 will be connected to this CH If the Line Type is set to Unframed in a dual channel FCD E1LC all the MAIN El timeslots will be connected to CH 2 Line coding method used for zero suppression HDB3 Loopback configuration of the selected port No Loop Not in loopback st
44. bit 8 of each 8 bit period of each channel Therefore only 7 bits per channel 1 344 Mbps is available for data B8ZS B8ZS coding A specified pattern of normal bits and bipolar variations replaces a sequence of 8 zero bits This option provides clear channel capability Trans Transparent AMI coding No zero suppression is present Reduces the time required for the T1 port to return to normal operation after local loss of synchronization TR 62411 Complies with AT amp T TR 62411 after 10 seconds Fast after 1 second This field is enabled only if Line Mode is CSU 0 7 5 15 22 5 This field is enabled only if Line Mode is DSU 0 133 134 266 267 399 400 533 534 655 Possible Values Remarks Identifier of the inband management of the selected link Off FDL or TSO Dedicated FR Note When Inband Mng FR do not set Line Code B7 this will cause an error message when a sanity check is performed Rate of Inband Mng NA when Inband Mng is Off 4 when Inband Mng is FDL or TSO 64 when Inband Mng is Dedicated FR Hexadecimal code transmitted to fill idle unused time slots in frames transmitted through the selected port To change the code type the required code in the edit box 00 Short Haul Long Haul Enabled Disabled Note RAI Enabled exists only for the Main port when a Sub port exists Field is disabled if Line Type Unframed Enabled Disabled Note Visible only for the Main port Port Lev
45. c G 704 Table 4a E1 CRC CCITT Rec G 704 Table 4b E1 MF CCITT Rec G 704 Table 4a with TS16 multiframing enabled E1 CRC MF CCITT Rec G 704 Table 4b with TS16 multiframing enabled Unframed for use when the data being transmitted is unframed Note 1 If the Line Type changed to Unframed clicking lt Set gt triggers a warning that all of FCD LC TS connections will be disconnected and the CH Rate set to 0 Note 2 If the Line Type is set to Unframed in a single channel FCD ETLC all the MAIN E1 Tss will be connected to this CH If the Line Type is set to Unframed in a dual channel FCD ETLC all the MAIN E1 timeslots will be connected to CH 2 Possible Values Remarks Line coding method used for zero suppression HDB3 Reduces the time required for the ET port to return to normal operation after local loss of synchronization TR 62411 Complies with AT amp T TR 62411 after 10 seconds CCITT Complies with CCITT Rec G 732 Fast after 1 second Identifier of the inband management of the selected link Off FDL or TSO Dedicated FR Rate of Inband Mng NA 4 8 12 16 20 when Inband Mng is FDL or TSO 64 when Inband Mng is Dedicated FR 0 3F FF Short Haul Long Haul Enabled Disabled Note RAI Enabled exists only for the Main port when a Sub port exists Field is disabled if Line Type Unframed Disabled Enabled Port Level Edit Menu 3 17 Chapter 3 Configuration Management RADview TDM FCD E1LC FCD T
46. commended for Elapsed Time gt 1 month Last Data i Refresh Get successful H Figure 4 2 Link Current Data Displaying G 826 Last Data Statistics gt To display the last data for a specific link e Select an entry in the G 826 Current Data list and click Last Data The Link Last Data dialog box appears 4 2 System Agent Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 4 Performance Monitoring KL A 1 Link Last Data ee xi Time Taq 0 days 0 00 00 Elapsed Time sec 9 UASs sesi 0 1 AR 36 Framesise Threshold ESs sec fo FR SESs sec 0 sEsR 34 BBEs b BER Threshold is recommended for Elapsed Time gt 1 month Get successful E Figure 4 3 Link Last Data Saving G 826 Statistics You can save data for entries in the list gt To Save amp Reset G 826 statistics 1 Click lt Save Reset gt The confirmation dialog box appears with the message Resetting G 826 Current Data of Main E1 T1 Link appears 2 Click lt OK gt to confirm the Save amp Reset 4 3 Port Edit Menu There are no performance monitoring tasks at this level 4 4 Port Agent Menu Vievving Port Statistics Note 1 Port Level Statistics is available for F1 T1 Main ports only and varies according to the type of the selected port 2 Port Statistics is available for ET line types ET E1 MF not CRC and for T1 line type D4 n
47. conds Sync Loss Events Error Bits Inject Error Command Stop Continuously Single Polling Clear Error Bits RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Table 2 9 BERT Counters Parameters Possible Values Remarks Main El Main T1 E1 T1 BER test pattern 511 2047 2E15 1 QRSS Rate of BERT injection No Error 1 On Off Sync Sync Loss Indicates how much time seconds passed since BERT started to run How many Errored Seconds were detected since BERT started to run How many times Sync Loss was detected since BERT started to run How many Error Bits were detected since BERT started to run Stops injection of BERT errors Continously injects bit errors Injects one error Clicking lt Polling gt opens BERT Polling Interval dialog box Figure 2 16 Resets error bit counter to zero gt To Inject Errors while testing Click lt Continuously gt or lt Single gt only one error is injected gt To stop Inject Errors while testing Click lt Stop gt gt To clear the Error Bits Click Clear Error Bits gt The error bits counter is reset to zero gt To set the BERT Polling Interval 1 Click lt Polling gt The BERT Polling Interval dialog box appears Figure 2 16 2 16 2 Set the polling interval 10 20 30 180 seconds by choosing a value from the drop down list box 3 Click lt Set gt Port Level Agent Menu RADview TDM FCD E1
48. ddress 17217152192 Type FECD ETLC SY Revision SOFTWARE REY 1 0042 Hy Yersion HARDWARE VER 0 06 Clock Source internal Self Test Result Master Clock Source Fallback Clack Source User Selected i Refresh Get successful m Figure 3 6 FCD Information Table 3 3 FCD Information Parameters Parameter Possible Values Remarks General IP Address Address of the selected VVAN agent double clicked in the VVAN submap Type FCD ETLC or FCD T1LC SVV Revision The Agents software version HVV Version The Agents hardvvare version Clock Source Source of the system clock Master Fallback Internal Self Test Result OK Failed Master Clock Source Master timing reference for FCD LC Type Main source for FCD ETLC FCD T1LC timing Internal Rx Clock Port The port through which the master clock signal is received For FCD ETLC NA MAIN E1 SUB E1 CH 1 CH 2 For FCD T1LC NA MAIN T1 SUB T1 CH 1 CH 2 3 8 System Level Agent Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 3 Configuration Management Table 3 3 FCD Information Parameters Cont Parameter Possible Values Remarks Fallback Clock Source Alternate fal back timing reference for the main link to be used in case the master clock fails Type Alternate source for FCD E1LC FCD T1LC timing Rx Clock None Por
49. e BPV AIS Occured AIS Sync Loss Local Syne Loss Local MF Alarm Rem MF Alarm Remote Sync Loss Frame Slip BP Error Excessive Error Rate CRC 4 Error Loop Inband ON Ming Port iz Looped Ming Port is Down CRC MF Alarm a z z z z Sel Cancel Get successful m Figure 2 12 Port Active Alarm List Table 2 7 Active Alarm List Parameter Possible Values Notes Port MAIN E1 MAIN T1 SUB El SUB T1 CH 1 CH 2 Port Type E1 11 HS Code Alarm code Description Text description Status Minor Major To save the list 1 Click Save to File The Save to File Dialog Box appears Figure 2 7 2 Enter filename and select type of file PDF or HTMD 3 Select location to save the file and click lt Save gt 2 12 Port Level Agent Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 2 Fault Configuration gt To print the list e Click lt Print gt The printer dialog box appears Clearing the Alarm Buffer gt To clear alarms e From the Fault menu select Alarms followed by Clear The alarms are cleared from the buffer Displaying Port Failures The Line Status command allows you to view failures if any in the selected port Note line Status is available for E1 T1 Main and Sub ports only gt To display port failures e From the Fault menu select Line Status The Line Status dialog box appears fea 4 1 172 17
50. each test The status can be Active or not active For CH 1 port BERT testing status is also included BERT Counter shows the number of bit errors detected during the BERT test gt To activate stop tests e Select appropriate command from the drop down list box and click lt Apply gt The agent stops and or starts the selected tests accordingly 2 14 Port Level Agent Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 2 Fault Configuration BERT Counters Note BERT parameters are available for Main port only e n order to see the BERT counters BERT test must running Start activate BERT testing from the Port Test Dialog Box gt To view the BERT counters e Diagnostics gt BERT Counters The BERT Counters Dialog Box appears si 4 1 172 17 152 192 BERT Counters Port Port Type BEFT Pattern 2E15 1 BERT Error Inject Rate 10E 1 Error Tx Inband Loop Ott Syne Status Syne Loss BERT Counters Run Time sec Errored Seconds Sync Loss Events Error Bits Inject Error Command Continuous Folling lz Clear Error Bits Close 3 sec to next polling H 42 24 Figure 2 15 BERT Counters CH 1 Agent Port Level Agent Menu 2 15 Chapter 2 Fault Configuration Parameter Port Port Type BERT Pattern BERT Error Inject Rate 10E Tx Inband Loop Sync Status BERT Counters Run Time sec Errored Se
51. ed Agent Mode The Agent mode bottom displays the current parameters of the agent currently operating This data includes system information hardvvare and softvvare interface information and channel configuration values The data displayed in the Agent mode may be used for comparison and analysis when preparing a configuration in the Edit Configuration mode Diagnostic operations can also be performed at the management station from the Agent mode In addition event and active alarm messages are accessed here If the Agent mode is selected the follovving appears e Window Title The window title identifies the selected mode A Agent the selected configuration 1 to 10 the FCD ETLC FCD T1LC name and its current status Connected or Disconnected e Window Menu Bar The Agent mode menu bar includes the Configuration Statistics Fault VVindovv Options and Help pull dovvn menus Menu contents differ when ports are selected Launching RADview FCD E1LC FCD T1 LC RADvievv TDM FCD E1LC FCD T1LC User s Manual Chapter 1 Introduction FCD T1LC only LEDs Table 1 1 describes the FCD E1LC LEDs on the front panel Table 1 1 FCD E1LC LEDs LED Name Color Remarks PWR Green On When power is on always in NMS Off When power is off TST Yellow Indicates that a test is running on one of the ports ALM Red On When there is a minor alarm Blinking When there is a major alarm ET LOC MAIN Red Indicates Local Sync Loss alarm
52. ed framing event 0 1 or more Frame synchronization bit error event 0 1 or more Line code violation event 0 1 or more Controlled SLIP event 0 1 or more Loopback on information bits payload Yes No Reserved for future use if needed 1 second report modulo 4 counter 4 10 Port Agent Menu Chapter 5 Configuring a Typical Application This chapter provides detailed instructions for setting up a typical application using two FCD ETLC units 5 1 Overview Application The section provides detailed instructions for configuring two FCD E1LCs on an El Network n x 64 kbps V 35 V36 X 21 LAN F CD E 1LC 1 1 1 1 E1 T1 Network FC DE 1LC nx 64kbps V 35 V 36 ce a V 35 V 36 Rout NMS D XC outer n x 64 kbps V 35 V36 X 21 Figure 5 1 FCD ETLCs on an ET Network Guidelines for Configuring Typical Application Certain guidelines are relevant to this application In general there are two basic configuration steps described below that need to be followed when deploying any FCD LC unit 1 IP Configuration Setting the device host IP address and the manager IP address 2 Physical layer configuration Setting the TDM parameters according to the application requirements and topology Overview 5 1 Chapter 5 Configuring a Typical ApplicationRADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Table 5 1 Configuration Summary D
53. el Edit Menu RADvievv TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 3 Configuration Management Note t you change Inband Mng from any value to Dedicated FR or from Dedicated FR to FDL or TSO a message is displayed Changing Inband Mng to from Dedicated FR may need resetting the device after performing Update CH 1 CH 2 Port Configuration gt To view Channel Port Configuration e Configuration gt Port Parameters gt Software Configuration The Port Software Configuration dialog box appears Port Port Type Rate Kbps txs4 Clock Mode DICE FIFO Size bit mz Or Clock Polarity Normal Figure 3 19 Port Software Configuration Dialog Box CH 1 Port Port Type Rate Kbps h 4 Clock Mode DICE FIFO Size bit m z Or Clock Polarity Normal Figure 3 20 Port Software Configuration Dialog Box CH 2 HS Tab 3 Change the parameters as required and click lt Set gt The parameters are changed to the new values Port Level Edit Menu 3 21 Chapter 3 Configuration Management RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual If the existing rate does not match the FIFO Size the following message appears on Note the Status Bar HFO Size Rate mismatch and Set operation is not performed until you match the FIFO size and the data channel rate Table 3 11 CH 1 CH 2 Port Configuration
54. erval Data The Interval Data dialog box appears The first line of the table in the screen below the graph Total sums the statistical data over the intervals elapsed in the last 24 hours or since the last reset of the device 4 6 Port Agent Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 4 Performance Monitoring GIN 172 17 152 230 Intervals Data Part Port Type Humber of Intervals o 12 41 14 36 1611 17 41 1926 21 11 2256 00 41 0225 0411 05 41 07 11 00 41 10 11 11 41 From Ah mm Intervals Ending Time For a different Views click on the Legend Errored Seconds ES Severe Errored Seconds SES Unavailable Seconds UAS 11 41 ii 6 El Close Ready H De 33 to next polling Figure 4 7 Intervals Data Table 3 4 Port Performance Interval Data Additional Parameters Parameter Number of Intervals Inv No From hh mm ss To hh mm ss Errored Seconds ES Severe Errored Seconds SES Unavailable Seconds UAS Controlled Slip Seconds CSS Possible Values Remarks Total number of 15 min intervals elapsed in the last 24 hours or since the last device reset 0 96 Number of the interval Starting time of the interval End time of the interval Number of seconds in the current interval in vvhich an event or alarm occurred Number of seconds in the current interval in vvhich at least 320 CRC events or one OOF event occu
55. evice E1 Parameters IP Parameters FCD LC A Line Type El IP address 172 17 152 192 FCD LC B e Line Type El IP address 172 17 152 230 5 2 Configuring FCD LC Units This section explains hovv to configure the FCD LC units The configuration procedure is similar for both units except for defining different host IP addresses Configuring the IP Parameters IP parameters are configured via the terminal application gt To configure the IP parameters 1 Display the IP menu Configuration gt System gt IP and configure the IP address of the FCD LC FCD LC A host IP address 172 17 152 192 FCD LC A host IP address 172 17 152 230 2 Save the changes Configuration gt System gt IP 1 IP ADDRESS 172 17 152 192 2 SUBNET MASK 255 255 255 0 2 ESC prev menu main menu 8 exit Figure 5 2 Configuring IP Parameters for FCD LC Configuring Manager List The Manager List command displays IP addresses of known Network Management Stations to which the FCD LC sends SNMP traps when an alarm occurs To receive an agent s traps the management station must type its own IP address in the Manager List The list may contain up to five entries gt To view modify the Manager List 1 From the Options menu select Manager List The Manager List dialog box appears 5 2 Configuring FCD LC Units RADview TDM FCD E1LC FCD T1LC Installation and Operation ManualChapter 5 Configuring a Typical Applicatio
56. g Box CH 1 3 22 3 19 Port Software Configuration Dialog Box CH 2 HS Tab 3 23 3 20 Port Software Configuration Dialog Box CH 2 Ethernet Tab 3 24 ee Oe e e 3 25 3 22 Port Software Configuration Dialog Box SP 3 26 3 23 Port Software Configuration Dialog Box DP ii iiiee iesii iii iiinnl 3 27 3 24 Port Software Configuration Parameters Main ET 3 29 3 25 Port Software Configuration Parameters Main T1 3 32 3 26 Port Software Configuration Dialog Box CPI ea 3 35 3 27 Ethernet Parameters Dialog Box rer 3 36 A A 3 37 PEI A o 7 E tie 4 2 150 AA E O E 4 2 25 Sn iii 4 3 45 T 4 4 4 5 Polling Interval E1 Agent ceros ironia 4 5 450 ricil as 4 6 10 si ii ir 4 8 e 7707070 77797 4 9 RADvievv TDM FCD E1L FCD T1L Installation and Operation Manual il Table of Contents List of Tables 1 8 1 2 System Level Management Options Edit Mode ss 1 9 1 3 System Level Management Options Agent Mode 1 10 1 4 Port Level Management Options Edit Mode 1 11 1 5 Port Level Management Options Agent Mode 1 17 KA aa a ya 7 2 4 De SB E 2 5 a AO ea ramos 2 6 AA E Em N 2 7 A 2 10 AMA o AA 2 10 277 od A dre ae ce a non 2 11 2 14 e A 2 16 20 JEE A e RON nosaoeentanaaess 3 1 32 FCD 7 mation 7
57. is enabled only when Pattern Configuration User Configured 2 10 Port Level Edit Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 2 Fault Configuration 2 4 Port Level Agent Menu Masking Port Alarms Masking alarms changes the alarm status of the FCD LC If you want the change to take place immediately you must clear the current alarms otherwise the effect will occur only after the next automatic system poll gt To mask alarms 1 Fault gt Alarms gt Mask 2 For each alarm you vvant to mask check the appropriate checkbox Note Choice of alarms for masking depends on selected port fea 4 1 172 17 152 192 Mask System Alarms All r Alarm Butter INIT_DE Switch ON Clock Fallback Clock Internal Clock Master Dial Out Cycle Failed DE Checksum PSA Switch ON DEF_PAR Switch ON Dial Cut Primary Call Failed Dial Out Alternate Call Failed Self Test a a a a a ee Duplicate Marne in Net Sel Cancel Get successful I N Figure 2 11 Port Mask Alarms Displaying Port Active Alarms List gt To list port active alarms Fault gt Alarms List The Port Active Alarms List appears Port Level Agent Menu 2 11 Chapter 2 Fault Configuration RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Port MAIN El Part Type El Al m Signal Loss Excessiv
58. itoring bral 4 1 172 17 152 230 Polling Interval Poling Interval sec TE Sel Cancel Figure 4 5 Polling Interval ET Agent Table 4 2 Polling Interval Parameters Parameter Possible Values Notes Polling Interval sec 5 10 15 20 25 30 35 40 45 50 55 60 Displaying Current Data Table and Graph gt To display the Current Data Table and Graph e Statistics gt Port Performance gt Current Data The Current Data dialog box appears 14 1 172 17 152 230 Current Data 230 250 270 290 Time Elapsed sec _ SEFS For a different view click on the Legend Time Elapsed sec Errored Seconds ES Severe Errored Seconds SES Unavailable Seconds UA Controlled Slip Seconds CSS Burst Errored Seconds BES Degraded Minutes DK Line Errored Seconds LES Severely Errored Framing Seconds SEF Loss of Frame Everts LOFC Close Pall et successtul Bl 6 sec to next polling Figure 4 6 Current Data Port Agent Menu 4 5 Chapter 4 Performance Monitoring Parameter Port Port Type Current Data Time Elapsed sec Errored Seconds ES Severe Errored Seconds SES Parameter Unavailable Seconds UAS Controlled Slip Seconds CSS Bursty Errored Seconds BES Degraded Minutes DM Line Errored Seconds LES Severely Errored Framing Seconds SEFS Loss of Frame Events LOFC RADview TDM FCD E1LC FCD
59. le Busy Signaling bits A and B are idle for 2 5 seconds then become busy until the out of service state ends In addition if the line type is ESF signaling bits C and D are busy for 2 5 seconds before switching to idle state Note only for enanled for Sub ports when Line Type E1 MF or E1 CRC MF Out of service code transmitted on time slots when the link is out of service This value must be the same for both ports To change the code type the required code in the edit box 00 7F FF Note only for enanled for Sub ports when Line Type E1 MF or E1 CRC MF This parameter enables the user to use the TSO Sa Bits 4 to 8 by 3 octets Zero One Management Each Sa bit is represented by a nibble where 0000 Zero 0001 One 0010 Management 0011 Transparent Management is available when Inband Mng is FDL or TSO l you change Inband Mng from any value to Dedicated FR or from Dedicated FR to FDL or TSO a message is displayed Changing Inband Mng to from Dedicated FR may need resetting the device after performing Update Port Level Edit Menu RADvievv TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 3 Configuration Management Parameter Port Port Type Line Type Line Mode Line Type Line Mode Line Code Syne Te Gain Mask dB Line Length feet Inband Ma Inband hind Rate Kbps Idle Code Rx Gain FA Enable Inband Loop Detection Figure 3 1
60. ling 1677 ik a 3 6 Displaying the alayla 3 8 nn aaa 3 6 Displaying FCD tee Iran oe nO OO A 77 3 6 Setting Systemi loloma 3 10 a AIE CO ARE E masi 3 11 Displaying Timeslot Routing ania Resettinetne PFED ETLC FEDETILO 3 13 ee r s ee 3 13 RADvievv TDM FCD E1L FCD T1L Installation and Operation Manual I Table of Contents 100115 Agent NA los 3 14 1 1017 EE r sap 3 14 Conun User IM de EE 3 14 Conigonne Por EE ee 3 15 7 POTE E EE 3 26 Displaying eler ET 3 26 Displaying Por CONS asa ot ts d aia 3 27 EIERE 3 38 Chapter 4 Performance Monitoring 27 SCT EC ii s l 4 1 Pe Pe ii 1 4 1 12 izi 4 1 Mee 4 1 22 10 OLU ie b eee ee 4 3 1 5 101 L 0 b Po ad 4 4 an a E 4 4 Viewing Port Performance RE 4 5 Displaying FDL Rx Messages FCD T1L Only Se ana 4 10 Chapter 5 Configuring a Typical Application SN 5 1 PADIS an 5 1 Guidelines for Configuring Typical Application ss 5 1 2 Conu CDS aaa aaa m n 5 2 Conu rm E 5 2 m i ni Spe a Coni nE RRE EE 5 3 Coni Ke nsn 5 3 List of Figures t RER EE 7770000000 770000 7 1 2 1 2 FCD E1L Edit Configuration in Focus 1 3 1 3 FCD T1IL Edit Configuration in E 1 4 T t FEDsETL Ascent Conti curacion im FOCUS ame no ne 1 5 1 5 FCD TIL Agent Conhiguration In FOCUS ae oo 1 6 E San Eneas Error 2 2
61. m Figure 3 24 Port Softvvare Configuration Dialog Box DP Table 3 14 Port Softvvare Configuration Parameters DP Parameter Possible Values Remarks Active Call Out Specifies when callout will be activated Alvvays Upon Link Fail Call Out Trigger Controls the use of the call out trigger None All Alarms Major Alarms Dial Retries O 8 Port Level Agent Menu 3 25 Chapter 3 Configuration Management RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Parameter Wait for Connect sec Dial Mode Alternate No Use Primary Dial No Alternate Dial No Table 3 14 Callout Parameters DP Tab Cont Possible Values Remarks Specifies the time FCD E1LC FCD T1LC will wait for an answer after each dialing attempt 30 45 60 Selects the dialing mode supported by the telephone network Tone Pulse Specifies if the alternate number will be dialed after the specified number of call attempts on the primary number failed No Yes up to 16 characters up to 16 characters Main E1 T1 amp Sub Port Software gt To display Software Port Configuration Configuration gt Port Parameters gt Software Configuration The Port Software Configuration dialog box appears Parameters for the FCD E1LC are shown in Figure 3 25 and Table 3 15 Parameters for the FCD T1LC are shown in Figure 3 26 and Table 3 16 3 26 Port Level Agent Menu RADview TDM FCD E1LC FCD T1LC Installation and Oper
62. ms Alarm Report dialog box See Defining Scope of Alarm Reports Alarm Buffer List See Displaying the History Log Alarm Buffer List See Displaying the History Log Self Test Results See Displaying Self Test Results Dialog Box and Parameter Location FCD Information dialog box See Displaying FCD Information System Information dialog box See Setting System Information Agent Date amp Time dialog box See Setting the Agent Date and Time TS Assignment Window See Displaying Timeslot Routing Connections Path Fault Alarms Mask Fault m Alarms m l ist m All Fault m Alarms m l ist m System level Fault m Alarms m Clear Fault m Alarms Clear All Fault we Alarms Report Fault gt History Log m l ist Fault m l listory Log m Clear Fault m Self Test Path Configuration FCD Info Configuration m System nfo Configuration m Date amp Time Configuration m TS Assignment System Level Operations 1 9 Chapter 1 Introduction RADview TDM FCD E1LC FCD T1LC User s Manual Table 1 3 System Level Management Options Agent Mode Cont Reset See Resetting the FCD Configuration Reset Tasks Statistics Dialog Box and Parameter Location Path Displaying G 826 Data G 826 Current Data Statistics See Displaying G 826 Statistics wG 826 Data Tasks Options Dialog Box and Parameter Location Path Configuring the
63. n 2 Enter change the IP addresses in the Manager List dialog box by clicking in the addresses field until it s highlighted Enter the new numbers in the address field Use the right and left arrows or mouse to jump to the next field 3 Click lt Set gt to display the updated IP Address in the Manager List fea 4 1 172 17 152 192 Manager List Manager ld IP Address 7248 159 37 lo 0 lo 0 lo 0 lo 0 Set Cancel Refresh Get successful E Figure 5 3 Manager List 5 3 Configuring TDM Parameters The following section outlines the steps to configure the TDM parameters for this application Configuring Line Type gt To configure the Main E1 Port Parameters 1 Select the Main E1 Port 2 From the Configuration menu select Port Parameters followed by Software Configuration The Port Software Configuration dialog box appears Figure 5 4 3 Set Line Type E1 4 Click lt Set gt Configuring TDM Parameters 5 3 Chapter 5 Configuring a Typical ApplicationRADview TDM FCD E1LC FCD T1LC Installation and Operation Manual zi F 11 172 17 152 132 Port Software Configuration HE MAIN E1 Line Type Line Code yc hbang Wing Inhan d Ming Rate Kbps NA ldle Code Rx Gain Long Haul FAI Enable Inband Loop Detection Disabled 54 Bits BIT 4 BIT 5 BIT BIT BIT 5 Figure 5 4 Port Software Configuration Parameters Main E
64. ng Rate kbps Idle Code hex Rx Gain RAI Enable Inband Loop Detection Table 3 16 T1 Port Software Configuration Parameters Cont Possible Values Remarks Reduces the time required for the T1 port to return to normal operation after local loss of synchronization TR 62411 Complies with AT amp T TR 62411 after 10 seconds Fast after 1 second This field is enabled only if Line Mode is CSU 0 7 5 15 22 5 This field is enabled only if Line Mode is DSU 0 133 134 266 267 399 400 533 534 655 Identifier of the inband management of the selected link Off FDL or TSO Dedicated FR Note When Inband Mng FR do not set Line Code B7 this will cause an error message when a sanity check is performed Rate of Inband Mng NA when Inband Mng is Off 4 when Inband Mng is FDL or TSO 64 when Inband Mng is Dedicated FR Hexadecimal code transmitted to fill idle unused time slots in frames transmitted through the selected port To change the code type the required code in the edit box 00 FF Short Haul Long Haul Enabled Disabled Note RAI Enabled exists only for the Main port when a Sub port exists Field is disabled if Line Type Unframed Enabled Disabled Note Visible only for the Main port CH Port Configuration gt To view Channel Port Configuration Configuration gt Port Parameters gt Software Configuration The Port Software Configuration dialog box appears 3 32 Port Level
65. nloading the Configuration to the Agent See Polling the Agent Dialog Box and Parameter Location Sanity Check Errors List See Viewing Sanity Check Errors Dialog Box and Parameter Location See Displaying Agent View 1 8 System Level Operations Path Configuration FCD Info Configuration m System Info Configuration m TS Assignment Configuration wRead Path Configuration Update Configuration m Poll Agent Path Fault Sanity Check Errors Path VVindovv m Agent View RADview TDM FCD E1LC FCD T1LC User s Manual Chapter 1 Introduction Table 1 3 lists the management options for FCD ETLC FCD T1LC possible in the Agent mode Table 1 3 System Level Management Options Agent Mode Tasks Fault Masking Alarms Displaying all active alarms Displaying active alarms on the system level Clearing active alarms Clearing all alarms Defining Scope of Alarm Reports Displaying History Log Clearing History Log Displaying Self Test Results Tasks Configuration Displaying FCD information Setting system information Setting Date and Time Displaying TS Assignment Dialog Box and Parameter Location Mask System Alarms dialog box See Masking Alarms All Active Alarm List See Displaying All Active Alarms Active System Level Alarm List See Displaying System Level Alarms See Clearing FCD LC Agent Alarms See Clearing FCD LC Agent Alar
66. o suppression B7 B7ZS coding lammed Bit zero suppression A pulse is forced in bit 8 of each 8 bit period of each channel Therefore only 7 bits per channel 1 344 Mbps is available for data B8ZS B8ZS coding A specified pattern of normal bits and bipolar variations replaces a sequence of 8 zero bits This option provides clear channel capability Trans Transparent AMI coding No zero suppression is present Loopback configuration of the selected port No Loop Not in loopback state Payload Loop Received signal at this port is looped through the FCD LC The signal is typically looped back for retransmission after passing through the agent s framing function Line Loop Received signal at this port does not go through the agent minimum penetration but is looped back out Other Loop Any loopback on the selected port that is undefined by the ports configuration Type of signaling transfer mode used by the selected card Robbed Bit Source of the card s transmit clock Loop Timing Recovered receive clock is the transmit clock Local Timing Local clock source is the transmit clock Through Timing Receive clock recovered from another port is used as the transmit clock of the selected port Port Level Agent Menu 3 31 Chapter 3 Configuration Management RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Parameter Sync TX Gain Mask dB Line Length feet Inband Mng Inband M
67. on MAIN link FCD E1LC only T1 RED MAIN Red Indicates Red alarm on MAIN link FCD T1LC only E1 REM MAIN Red On When there is a Remote Sync Loss alarm on the Main link FCD E1LC only T1 YEL MAIN Yellow On when there is a Yellow Alarm on the Main link FCD T1LC only E1 LOC SUB Red Indicates Local Sync Loss alarm on SUB link FCD E1LC only T1 RED SUB Red Indicates Red alarm on SUB link FCD T1LC only E1 REM SUB Red Indicates Remote Sync Loss alarm on SUB link FCD E1LC only T1 YEL SUB Yellow Indicates Yellow alarm on SUB link Launching RADview FCD E1LC FCD T1LC 1 7 Chapter 1 Introduction RADvievv TDM FCD E1LC FCD T1LC User s Manual 1 4 System Level Operations Table 1 2 lists the system management options for FCD ETLC FCD T1LC possible in the Edit mode Table 1 2 System Level Management Options Edit Mode Tasks Configuration Configuring FCD information Displaying system information Configuring TS Assignment Read Tasks Fault Update Poll Agent Tasks Fault Displaying Sanity Check Errors Tasks Window Displaying Edit Agent View Dialog Box and Parameter Location FCD information dialog box See Configuring FCD Information System Information dialog box See Displaying System Information TS Assignment dialog box See Configuring Timeslot Assignment See Reading Uploading the Agent Configuration Dialog Box and Parameter Location See Updating Dow
68. onfiguring Port Parameters Control Port Parameters gt To display the parameters of the CONTROL DCE port 1 Select the SP Supervisory Port icon 2 Configuration gt Port Parameters gt Software Configuration Or e Click the shortcut key on the toolbar Bl Port Level Edit Menu 3 13 Chapter 3 Configuration Management RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual The Port Software Configuration dialog box appears CONTROL DCE SP Usage hms Slip Rate bps 1 3200 Data Bits Parity Interface ES Figure 3 15 CONTROL DCE Port Configuration SP Tab e Select the SP tab to define the supervisory port parameters e Select the DP tab to define call out parameters CONTROL DCE SP Active Call Out Always Call Out Trigger More Dial Retries Wait for Connect Sec Dial Mode Alternate Mo Use Primary Dial No Alternate Dial Ma Figure 3 16 CONTROL DCE Port Configuration DP Tab 3 14 Port Level Edit Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Parameter Usage Rate bps Data Bits Parity Interface CTS Parameter DCD Delay msec DSR Activate Call Out Call Out Trigger Dial Retries Wait for Connect sec Dial Mode Alternate No Use Primary Dial No Alternate Dial No Chapter 3 Configuration Management Table 3 8 CONTROL DCF Port Configuration Parameters
69. ot ESF only Port Agent Menu 4 3 Chapter 4 Performance Monitoring RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual gt To view port status statistics e Statistics gt Port Statistics The Port Statistics dialog box appears 314 1 172 17 152 230 Port Statistics xj rer _ x MAIN TI Port Type T1 OOS Count EP Last Minute EP Get successful m Figure 4 4 Port Statistics Table 4 1 Port Statistics Parameter Possible Values Remarks Port Main E1 Sub E1 Main T1 Sub E1 Port Type E1 11 OOS Count Number of detected frame alignment loss events since the last time the counter was cleared BPV Last Minute Number of BPV bipolar variation events detected in the last minute BPV Max Highest total of BPV events detected during any one minute interval since the last time the counter was cleared Viewing Port Performance Data Note Port Performance Data is available for ET line types E CRC F1 CRC MF with CRO and for T1 line type D4 only You can view a selected 15 minute interval or cumulative totals of the data from the previous 24 hours Polling Interval gt To select the Polling Interval e Statistics gt Port Performance gt Polling Interval The Polling Interval dialog box appears 4 4 Port Agent Menu RADvievv TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 4 Performance Mon
70. p NMS PPP Agent Slip Terminal When Usage Terminal Auto 1200 2400 4800 9600 19200 38400 57600 115200 When Usage Terminal 1200 2400 4800 9600 19200 38400 57600 115200 Number of data bits in the vvord format transmitted through the selected port 7 8 Parity mode used by the selected port None Odd Even Type of supervisory port interface DCE for direct connection to supervision terminal DTE for connection through a modem to supervision terminal State of the CTS Clear to Send line in the selected port On CTS is always on RTS CTS line follows the local RTS line 3 24 Port Level Agent Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 3 Configuration Management Table 3 13 Port Software Configuration Parameters SP Cont Parameter Possible Values Remarks DCD Delay msec Time delay between Data Carrier Detection DCD and the sending of the data if the interface type is DTE 0 10 50 100 200 300 DSR State of the DSR line On DSR line is continuously on DTR DSR line tracks the DTR line gt To view DP parameters e Configuration gt Port Parameters gt Software Configuration gt DP tab xl Port CONTROL DCE Active Call Out Always Call Cut Trigger Mone Dial Retrie Wal for Connect sec 21 Dial Mode Tone Alternate Mo Use Mo Primary Dial No Alternate Dial tda Close Refresh Get successful
71. pdate fea 4 1 172 17 152 230 Port Software Configuration syne ne Lert hbang ng Ott hbang Ming Rate Kbps Idle Code Rx Gain Short Haul FAI Enable 1 Inband Loop Detection Disabled Close Refresh Working Figure 3 26 Port Software Configuration Parameters Main T1 3 30 Port Level Agent Menu RADvievv TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 3 Configuration Management Parameter Port Port Type Line Type Line Mode Line Code Loopback Config Signal Mode Tx Clock Source Table 3 16 T1 Port Software Configuration Parameters Possible Values Remarks Main T1 11 Type of T1 line implementing the selected circuit The type of circuit affects the number of frames that the circuit can carry ESF Extended Superframe DS1 24 frames per multiframe D4 AT amp T D4 format DS1 12 frames per multiframe Unframed for use when the data being transmitted is unframed Note 1 If the Line Type changed to Unframed clicking lt Set gt triggers a warning that all of FCD LC TS connections will be disconnected and the Rate set to 0 Note 2 If the Line Type is set to Unframed in a single channel FCD T1LC all the MAIN T1 Tss will be connected to this CH If the Line Type is set to Unframed in a dual channel FCD T1LC all the MAIN T1 timeslots will be connected to CH 2 Line mode for selected port CSU or DSU Line coding method used for zer
72. rred Number of seconds in the current interval in vvhich a failed signal state exists A failed signal state occurs after 10 consecutive severe errored seconds This state is cleared only after FCD LC processes 10 consecutive seconds of data without an SES Number of seconds in the current interval in vvhich at least one controlled SLIP event occurred Port Agent Menu 4 7 Chapter 4 Performance Monitoring RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Bursty Errored Seconds Number of seconds in the current interval in which 2 319 CRC events occurred BES Degraded Minutes DM Number of minutes in the current interval in which the bit error rate BER exceeded 1x10 6 Line Errored Seconds Number of seconds in which one or more Line Code Violation events were LES detected Severely Errored Number of seconds vvith 320 or more OOF events or one or more AlS event Framing Seconds SEFS Loss of Frame Events LOFC Reset Statistics gt To reset statistics e Statistics gt Port Performance gt Reset Statistics The following message appears Resetting lt MAIN or SUB gt Port s Intervals Click lt OK gt to confirms reset Displaying FDL Rx Messages FCD T1LC only You can view active FDL Facility Data Link Rx messages that have passed through the Main T1 port of the FCD T1LC provided it is configured to Line Type ESF gt To view FDL Rx messages 1 Select the Main T1 port 2 Statistics
73. service state ends In addition if the line type is ESF signaling bits C and D are idle for 2 5 seconds before svvitching to busy state Idle Busy Signaling bits A and B are idle for 2 5 seconds then become busy until the out of service state ends In addition if the line type is ESF signaling bits C and D are busy for 2 5 seconds before svvitching to idle state Note only for enanled for Sub ports when Line Type E1 MF or E1 CRC MF Out of service code transmitted on time slots vvhen the link is out of service This value must be the same for both ports To change the code type the required code in the edit box 00 7F FF Note only for enanled for Sub ports when Line Type E1 MF or El CRC MF Rate of Inband Mng NA when Inband Mng is Off FDL or TSO 64 when Inband Mng is Dedicated FR Port Level Agent Menu 3 29 Chapter 3 Configuration Management RADvievv TDM FCD E1LC FCD T1LC Installation and Operation Manual Bit 4 This parameter enables the user to use the TSO Sa Bits 4 to 8 by 3 octets Bit 5 Zero One Management Transparent Bit 6 Each Sa bit is represented by a nibble where Bit 7 0000 Zero Bit 6 0001 One 0010 Management 0011 Transparent Management is available when Inband Mng is FDL or TSO Note If you change Inband Mng from any value to Dedicated FR or from Dedicated FR to FDL or TSO a message is displayed Changing Inband Mng to from Dedicated FR may need resetting the device after performing U
74. t eg 4 1 172 17 152 192 Manager List xi Manager ld IP Address 1 7248 159 37 2 lo 0 0 0 3 lo 0 0 0 4 lo 0 0 0 5 lo 0 0 0 Set Cancel Refresh Get successful N Figure 3 13 Manager List Table 3 6 Manager List Parameter Possible Values Remarks Manager ID Index number in the list of the management station IP Address IP address of the management station Displaying the Agent View If the Edit Configuration only is displayed on the screen you may open the Agent view if the agent is connected 3 12 System Level Agent Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 3 Configuration Management gt To open the agent part of the application window e Window gt Agent View The Agent Configuration appears below the Edit Configuration 3 3 Port Level Edit Menu Configuring User Information Note User Information is available only for Main E1 T1 CH 1 and CH 2 ports To set User Information e Configuration gt User Information few E 1 172 17 152 192 User Inform atio Port MAIN E1 User Marne User Info Set Cancel EE E Figure 3 14 User Information Table 3 7 User Information Parameters SP Parameter Possible Values Remarks Port title Main E1 Main T1 CH 1 CH 2 User Name Editable field of 15 characters User Info Editable field of 70 characters C
75. t Possible Values Remarks Rate of Inband Mng NA 4 8 12 16 20 when Inband Mng is FDL or TSO 64 when Inband Mng is Dedicated FR 0 3F FF Short Haul Long Haul Enabled Disabled Note RAI Enabled exists only for the Main port when a Sub port exists Field is disabled if Line Type Unframed Disabled Enabled Method used to signal the carrier group alarm CCA state to the other end of the selected link None Non transparent mode VVhen one of the links is in out of service state the time slots carry the appropriate out of service code data voice OOS to the other end of the link Trans VVhen one of the links is in out of service state the time slots carry the appropriate OOS code to the other end of the link Signaling bits A and B are not forced into the OOS state Full Fully transparent mode When one of the links is in out of service state the state of the time slots and the state of the signaling bits does not change State of the signaling bits when the link is in out of service OOS state Forced Idle Signaling bits A and B are idle when the link is in out of service state n addition if the line type is ESF signaling bits C and D are also idle Forced Busy Signaling bits A and B are busy vvhen the link is in out of service state In addition if the line type is ESF signaling bits C and D are also busy Busy Idle Signaling bits A and B are busy for 2 5 seconds then become idle until the out of
76. t gt Alarms gt List gt System Level The FCD Active Alarm List appears The FCD Active List displays active system alarms If the list is long you can click the scroll bar or scroll arrows to display more entries Table 2 2 FCD Active Alarm List Parameter Possible Values Remarks Code Code which indicates a certain alarm description Description Description of the alarm Status State of the alarm Minor Major 2 4 System Level Agent Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 2 Fault Configuration 14 1 172 17 152 192 FCD Active Alarm List Status FB CLOCK WS CHANGED TO INTERNAL Minor Print Save to File Clear Close Refresh Get successful m Figure 2 4 FCD Active Alarm List Clearing FCD LC Agent Alarms You can clear only system level alarms or all active alarms from the system database gt To clear active system level alarms Fault gt Alarms gt Clear The system does not request confirmation for this operation gt To clear all active alarms Fault gt Alarms gt Clear All The system does not request confirmation for this operation Defining Scope of Alarm Reports Using the Reports command you can define the severity of alarm reports received at the network management station gt To define an alarm report 1 Fault gt Alarms gt Report The Alarm Report dialog box appears where you can set the severity cri
77. t The port through which the fallback clock signal is received For FCD E1LC MAIN ET SUB E1 CH 1 CH 2 For FCD T1LC MAIN T1 SUB T1 CH 1 CH 2 Svvitches Status DEF PAR Source of the supervisory port parameters Default 1 Other 0 PSVV Source of the passvvord and management address node number of the supervisory port Default 1 User Selected 0 INIT DB This parameter determines vvhich FCD LC configuration vvill be loaded after FCD LC is turned off for a short time and then turned on again Default 1 NVRAM 0 Setting System information The System Information command enables you to configure information about the system gt To display System Information e Configuration gt System Info The System Information dialog box appears beg 4 1 172 17 152 192 System Information xj Description 0 11 SW 1 00A3 H 00 01 Object ID 112 Marne FFco Lc Contact name of contact person Location location of device system Up Time O days 01 22 35 Number of Interfaces 1 Sel Cancel Get successful N Figure 3 9 System nformation System Level Agent Menu 3 9 Chapter 3 Configuration Management RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Table 3 4 System Information Parameter Possible Values Notes Description SW and HW versions Name FCD E1LC or FCD T1LC Contact User specified Location User specified Setting the Agent Da
78. te and Time You can set the current FCD LC date and time There are three different display formats for the date e European DD MM YYYY e American MM DD YYYY e YYYY MM DD gt To set the date and time 1 Configuration gt Date amp Time The Date amp Time Setup dialog box appears 2 Configure desired Date amp Time parameters 3 Click lt Set gt TIESI 172 17 152 192 Date amp Time Setup 5 i x Format RAMA Date 2004 01 01 Time 22 18 53 Set Cancel Get successful L Figure 3 10 Agent Date A Time Table 3 5 Agent Date amp Time Parameter Possible Values Remarks Format This parameter is read only European format DD MM YYYY American format MM DD YYYY or YYYY MM DD Date Month Day Year Time Time in HH MM SS format where HH Hour MM minutes SS seconds Displaying Timeslot Routing Connections In the Agent Mode you can view the actual timeslot assignments for all ports but you cannot connect or disconnect the timeslots 3 10 System Level Agent Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 3 Configuration Management gt To display the Port level TS Assignment window e Configuration gt TS Assignment Or e Click the shortcut key on the toolbar La The TS Assignment window appears This window displays the timeslot connections for FCD LC ports
79. teria for reporting alarms 2 Set the severity levels in each field 3 Click lt Set gt System Level Agent Menu 2 5 Chapter 2 Fault Configuration RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual beg 4 1 172 17 152 192 Alarm Report Alarm On Severity Alarm Off Severity Trap ula ala gl Ino Report E Set Cancel Get successful E Figure 2 5 Alarm Report Dialog Box Table 2 3 Alarm Report Parameters Parameter Possible Values Remarks Trap Alarm On Severity Minimum level of severity required for sending a trap to the network management station No Report Minor Major Alarm Off Severity Maximum level of severity allowed for a trap not to be sent to the network management station No Report Minor Major Displaying the History Log The history log contains all the alarms listed in FCD LC alarm buffer in chronological order of occurrence The buffer s capacity is 256 alarms You may view and print its contents gt To display all the alarms in FCD LC history alarm buffer e Fault gt History Log gt List The Alarm Buffer List appears 2 6 System Level Agent Menu RADview TDM FCD E1LC FCD T1LC Installation and Operation Manual Chapter 2 Fault Configuration beg 4 1 172 17 152 192 Alarm Buffer List Baa Port Description Date Time 8 O CLOCK WAS CHANGED TO INTERNAL Minor 2004 01 01 00 00 15 M 25MANEI LOCAL SYNC LOSS Maor 2
80. ving pages TS Color Codes Since each TS has only one type and can be connected to only one port each TS column can have only one cell with a letter inside Both connection cells and port indicator cells use color codes to relay connection information 5 Green number Gray number Gray empty Blue number Blue empty Yellow letter Red number White number White empty TS in this port is connected and is not being used for Management TS in this port is available for connection but currently has no TS connection Cellis port has no current TS connections but can be TS connected TS in this port has no connections and cannot be TS connected Cellis port has a TS connection Cellis port has at valid TS connection of type indicated by letter There is an invalid connection TSs in this port is connected and being used for Management Cellis port is being used for Management Port Name Color Codes Green All of the ports connectable TS connections are connected Gray None of the ports connectable TSs are being used Red This occurs when one of the port s cells is red Yellow Some of the TSs are connected Creating TS Connections You can create a new TS connection only on gray cells cells with connectable TSs gt To create a new TS connection Click an empty gray cell and click lt Data gt button The cell becomes yellow and the