1. Managing the PE653 as a Z-Wave device 1.1. CLOCK Command

image

Contents

1. e The configurationValue3 byte sets the Variable Speed Pump Speed to be activated upon detection of a freeze condition This can be any one of the following values Variable Speed Pump Speed to activate during a configurationValue3 freeze condition value NONE 0x00 Variable Pump Speed 1 0x01 Variable Pump Speed 2 0x02 Variable Pump Speed 3 0x03 Variable Pump Speed 4 0x04 e The configurationValue4 byte shall always be set to zero 1 4 ASSOCIATION Command Class The ASSOCIATION command Class is fully supported as documented in the Z Wave Command Class Specification The PE653 supports only one association group Group ID 1 and that group can contain a maximum of five associated devices 1 5 SWITCH_BINARY Command Class The SWITCH_BINARY command Class is fully supported as documented in the Z Wave Command Class Specification The PE653 supports five instances of this command class one for each of the five circuit push buttons on the front of the PE653 Instance one of the command class manages Circuit 1 Instance two manages Circuit 2 and so on 1 6 THERMOSTAT_SETPOINT Command Class The THERMOSTAT_SETPOINT command Class is fully supported as documented in the Z Wave Command Class Specification for support setpoint tyoes HEATING 1 setpoint type 1 and FURNACE setpoint type 7 The remaining setpoint types are unsupported The HEATING 1 setpoint is used for setting the POOL ta
2. VSP_SPD_SETTING_4 0x23 Used to set the variable speed pumps 4th activation speed VSP Speed 4 VSP_SPD_1_EV_SCHED_1 0x24 Used to set or clear the 1 of three possible ON OFF activation schedules for VSP Speed 1 VSP_SPD_1_EV_ SCHED 2 0x25 Used to set or clear the 2nd of three possible ON OFF activation schedules for VSP Speed 1 VSP_SPD_1_EV_ SCHED 3 0x26 Used to set or clear the 3rd of three possible ON OFF activation schedules for VSP Speed 1 VSP_SPD_ 2 EV_SCHED_1 0x27 Used to set or clear the 1 of three possible ON OFF activation schedules for VSP Speed 2 VSP_SPD_2 EV SCHED 2 0x28 Used to set or clear the 2nd of three possible ON OFF activation schedules for VSP Speed 2 VSP_SPD_2 EV_SCHED 3 0x29 Used to set or clear the 3rd of three possible ON OFF activation schedules for VSP Speed 2 VSP_SPD_3_EV_SCHED_1 Ox2A Used to set or clear the 1 of three possible ON OFF activation schedules for VSP Speed 3 VSP_SPD_3 EV SCHED 2 0x2B Used to set or clear the 2nd of three possible ON OFF activation schedules for VSP Speed 3 VSP_SPD_3 EV SCHED 3 Ox2C Used to set or clear the 3rd of three possible ON OFF activation schedules for VSP Speed 3 VSP_SPD_4 EV_SCHED 1 0x2D Used to set or clear the 1 of three possible ON OFF activation schedules for VSP Speed 4 VSP_SPD_4 EV SCHED 2 Ox2E Used to set or clear the 2nd of three possible ON OFF activation schedules for VSP Speed 4 VSP_SPD_4 EV_SCHED 3 Ox2F Used to set or clea
3. with cool down period 4 minute 0x04 Fireman Enabled heater installed with cool down period 5 minute 0x05 Fireman Enabled heater installed with cool down period 6 minute 0x06 Fireman Enabled heater installed with cool down period 7 minute 0x07 Fireman Enabled heater installed with cool down period 8 minute 0x08 Fireman Enabled heater installed with cool down period 9 minute 0x09 Fireman Enabled heater installed with cool down period 10 minute Ox0A Fireman Enabled heater installed with cool down period 11 minute 0x0B Fireman Enabled heater installed with cool down period 12 minute 0x0C Fireman Enabled heater installed with cool down period 13 minute 0x0D Fireman Enabled heater installed with cool down period 14 minute Ox0E Fireman Enabled heater installed with cool down period 15 minute OxOF PE653 Temperature Calibration Offsets 0x03 The PE653 allows the user to configure whether or not temperature compensation should be applied to the actual temperatures read for the air temp and or water temperature You may wish to apply an offset to have the PE653 temperature readings match those of a different device or thermometer To configure this behavior issue a Configuration Set command with the e The parameterNumber byte set to 0x03 e The level byte set to four 4 e g a four byte value being sent e The configurationValue1 byte sets the amount of compensation you wish to ap
4. set to 0x32 The level byte set to four 4 e g a four byte value being sent The configurationValue1 byte sets the temperature threshold at which a freeze condition is present This setting is in degrees Fahrenheit and has a valid range of 34F to 44F inclusive in 1 degree Fahrenheit increments The configurationValue2 byte sets the PE653 circuits to be activated upon detection of a freeze condition This can be any one of the following values Turn Turn Turn Turn Turn Circuit 5 Circuit 4 Circuit3 Circuit 2 Circuit 1 configurationValue2 ON ON ON ON ON value NO NO NO NO NO 0x00 NO NO NO NO YES 0x01 NO NO NO YES NO 0x02 NO NO NO YES YES 0x03 NO NO YES NO NO 0x04 NO NO YES NO YES 0x05 NO NO YES YES NO 0x06 NO NO YES YES YES 0x07 NO YES NO NO NO 0x08 NO YES NO NO YES 0x09 NO YES NO YES NO Ox0A NO YES NO YES YES 0x0B NO YES YES NO NO 0x0C NO YES YES NO YES 0x0D NO YES YES YES NO Ox0E NO YES YES YES YES 0x0F YES NO NO NO NO 0x10 YES NO NO NO YES 0x11 YES NO NO YES NO 0x12 YES NO NO YES YES 0x13 YES NO YES NO NO 0x14 YES NO YES NO YES 0x15 YES NO YES YES NO 0x16 YES NO YES YES YES 0x17 YES YES NO NO NO 0x18 YES YES NO NO YES 0x19 YES YES NO YES NO 0x1A YES YES NO YES YES 0x1B YES YES YES NO NO 0x1C YES YES YES NO YES 0x1D YES YES YES YES NO 0x1E YES YES YES YES YES 0x1F
5. 1 Managing the PE653 as a Z Wave device The PE653 as a Z Wave certified device is completely manageable via its Z Wave command class implementation The PE653 is by implementation a Z Wave device which is built upon the Generic Device type of SWITCH BINARY and the Specific device type of Binary Power Switch It supports the following list of Z Wave command classes Z Wave Command Class Command Number of Class Version instances POWERLEVEL 1 MANUFACTURER_SPECIFIC VERSION CLOCK MULTL INSTANCE CONFIGURATION ASSOCIATION SWITCH_BINARY SWITCH_ALL THERMOSTAT_SETPOINT SENSOR_MULTILEVEL k mi a Sy a A All command classes are fully Z Wave compliant as per Version 7 of the Z Wave Command Class Specification Command Class specific qualifiers to support are listed below 1 1 CLOCK Command Class The CLOCK command Class is fully supported as documented in the Z Wave Command Class Specification for support of a 24 hour clock The PE653 does not support weekday settings 1 2 MULTI INSTANCE Command Class The MULTI INSTANCE command Class is fully supported as documented in the Z Wave Command Class Specification for support for managing the five instances of the SWITCH_BINARY command class 1 3 CONFIGURATION Command Class The CONFIGURATION command Class is fully supported as documented in the Z Wave Command Class Specification for the following con
6. 3rd of three possible ON OFF activation schedules for Circuit 2 CIR_3_ EV SCHED _1 Ox0A Used to set or clear the 1 of three possible ON OFF activation schedules for Circuit 3 CIR_3_ EV SCHED 2 Ox0B Used to set or clear the 2nd of three possible ON OFF activation schedules for Circuit 3 CIR_3 EV SCHED 3 Ox0C Used to set or clear the 3rd of three possible ON OFF activation schedules for Circuit 3 CIR_4 EV SCHED _1 Ox0D Used to set or clear the 1 of three possible ON OFF activation schedules for Circuit 4 CIR_4 EV SCHED 2 OxOE Used to set or clear the 2nd of three possible ON OFF activation schedules for Circuit 4 CIR_4 EV SCHED 3 OxOF Used to set or clear the 3rd of three possible ON OFF activation schedules for Circuit 4 CIR_5 EV SCHED _1 0x10 Used to set or clear the 1 of three possible ON OFF activation schedules for Circuit 5 CIR_5 EV SCHED 2 0x11 Used to set or clear the 2nd of three possible ON OFF activation schedules for Circuit 5 CIR_5_EV_SCHED 3 0x12 Used to set or clear the 3rd of three possible ON OFF activation schedules for Circuit 5 POOL_SPA_SUPPORT_ MODE 0x13 Used to select whether the PE653 is controlling a POOL only SPA only or both POOL and SPA VSP_SPD_SETTING_1 0x20 Used to set the variable speed pumps 1 activation speed VSP Speed 1 VSP_SPD_SETTING_2 0x21 Used to set the variable speed pumps 2nd activation speed VSP Speed 2 VSP_SPD_SETTING_3 0x22 Used to set the variable speed pumps 3rd activation speed VSP Speed 3
7. e configuration parameter 0x31 description for more details To configure this behavior issue a Configuration Set command with the e The parameterNumber byte set to one of the values of 0x20 through 0x23 e The level byte set to two 2 e g a two byte value being sent e The configurationValue1 byte set to the high 8 bits of the desired 16 bit pump speed setting e The configurationValue2 byte set to the low 8 bits of the desired 16 bit pump speed setting 1 1 7 Variable Speed Pump Speed Schedules 0x24 through 0x2F The PE653 allows the user to configure whether or not there will be scheduled ON and OFF times created to turn a variable speed pump speed ON OFF during a 24 hour period Each variable soeed pump speed can have up to 3 scheduled activation times applied to it Each scheduled ON OFF activation time MUST have a valid ON and OFF time assigned The ON and OFF times are 16 bit values and minutes from midnight where midnight equals 0 NOTE Only one pump speed can be active at a time To configure this behavior issue a Configuration Set command with the e The parameterNumber byte set to one of the values 0x24 through Ox2F e The level byte set to four 4 e g a four byte value being sent e The configurationValue1 byte set to the high 8 bits of the 16 bit schedule ON time e The configurationValue2 byte set to the low 8 bits of the 16 bit schedule ON time e The configurationValue3 byt
8. e set to the high 8 bits of the 16 bit schedule OFF time e The configurationValue4 byte set to the low 8 bits of the 16 bit schedule OFF time 1 1 8 Variable Speed Pump MAX Pump Speed Settings 0x31 The PE653 allows the user to configure what the MAXIMUM allowable activation speed can be for any of the four variable speed pump speed settings The Maximum pump speed setting can be set to any of the valid PUMP Speed settings which is the range 400 to 3450 RPM inclusive in 10 RPM increments If a Maximum Pump speed setting is applied any existing set pump speeds that exceed the Maximum value will automatically be set to the new Maximum Speed setting To configure this behavior issue a Configuration Set command with the The parameterNumber byte set to one of the values of 0x31 The level byte set to two 2 e g a two byte value being sent The configurationValue1 byte set to the high 8 bits of the desired 16 bit Maximum pump speed setting The configurationValue2 byte set to the low 8 bits of the desired 16 bit Maximum pump speed setting 1 1 9 PE653 Freeze Control 0x32 The PE653 allows the user to configure whether or not Freeze Control operation is enabled for this installation If it is the user can further specify what pump s and or variable speed pump speed is activated when a freeze condition occurs To configure this behavior issue a Configuration Set command with the The parameterNumber byte
9. figuration parameters The CC Parameter Number value in the table below is the value used to populate the parameterNumber byte of the Configuration Command Class packet The Configuration Report messages received from the PE653 will be identical in format to the Set messages with the exception of the cmd byte being REPORT instead of SET cc Configuration Parameter CC Parameter Number Number name value Description PE653 OPERATION MODE 0x01 FIREMAN_TIMEOUT 0x02 Used to Disable enable and set fireman cool down durations for preventing heater over heating TEMP_CALIBRATION_OFFSETS 0x03 Sets temperature offsets which will then be applied to the actual pool and or spa temperature measured by the PE653 CIR_1_EV_SCHED_1 0x04 Used to set or clear the 1 of three possible ON OFF activation schedules for Circuit 1 CIR_1_EV_ SCHED 2 0x05 Used to set or clear the 2nd of three possible ON OFF activation schedules for Circuit 1 CIR_1_EV_ SCHED 3 0x06 Used to set or clear the 3rd of three possible ON OFF activation schedules for Circuit 1 CIR_2 EV SCHED _1 0x07 Used to set or clear the 1 of three possible ON OFF activation schedules for Circuit 2 CIR_2 EV SCHED 2 0x08 Used to set or clear the 2nd of three possible ON OFF activation schedules for Circuit 2 CIR_2 EV SCHED 3 0x09 Used to set or clear the
10. lue1 byte set to the high 8 bits of the 16 bit schedule ON time e The configurationValue2 byte set to the low 8 bits of the 16 bit schedule ON time e The configurationValue3 byte set to the high 8 bits of the 16 bit schedule OFF time e The configurationValue4 byte set to the low 8 bits of the 16 bit schedule OFF time 1 1 5 PE653 Pool Spa Installation configuration 0x13 The PE653 allows the user to configure whether the pool spa installation consists of a POOL only a SPA only or both To configure this behavior issue a Configuration Set command with the e The parameterNumber byte set to 0x13 e The level byte set to one 1 e g a one byte value being sent e The configurationValue1 byte set to one of the following Installed POOL SPA Configuration configurationValuet A POOL ONLY installation 0x00 A SPA ONLY installation 0x01 Both a POOL and SPA are part of the installation 0x02 1 1 6 Variable Speed Pump Speed Settings 0x20 through 0x23 Some installations will have a Variable Speed Pump installed instead of a one or two speed pump In these installations the PE653 allows the user to configure what the activation speeds for the four variable speed pump speed settings will be set to The range for these settings is a 400 to 3450 RPM inclusive in 10 RPM increments The high end of the speed range can be further restricted via the VSP maximum speed configuration setting se
11. p is a one or two speed pump o Whether the Booster Cleaner is installed or not The valid setting for this field is the combination logical ORing of these two pieces of information This field can have the following values applied to it Installed Pump Type Boosier Cleaner Installed configurationValue2 One Speed NO 0x00 One Speed YES 0x01 Two Speed NO 0x02 Two Speed YES 0x03 1 1 2 1 1 3 1 1 4 PE653 Fireman Timeout 0x02 The PE653 allows the user to configure whether there is a fireman cool down period associated with an attached heater circuit 5 and if there is how long the cool down period will be You may use this Configuration parameter to set these modes To configure this behavior issue a Configuration Set command with the e The parameterNumber byte set to 0x02 e The level byte set to one 1 e g a one byte value being sent e The configurationValue1 byte set to one of the following Fireman state and timeout to be applied configurationValuet Fireman Disabled no heater installed OxFF Fireman Enabled heater installed with no cool down period 0x00 Fireman Enabled heater installed with cool down period 1 minute 0x01 Fireman Enabled heater installed with cool down period 2 minute 0x02 Fireman Enabled heater installed with cool down period 3 minute 0x03 Fireman Enabled heater installed
12. ply to the actual water pool spa reading taken by the PE653 This value is an offset in degrees Fahrenheit and may have the value of 20F to 20F in 1 degree increments inclusive Only whole number offsets are allowed A setting of zero results in NO offset being applied e The configurationValue2 byte sets the amount of compensation you wish to apply to the actual Air freeze protection reading taken by the PE653 This value is an offset in degrees Fahrenheit and may have the value of 20F to 20F in 1 degree increments inclusive Only whole number offsets are allowed A setting of zero results in NO offset being applied e The configurationValue3 byte shall always be set to zero e The configurationValue4 byte shall always be set to zero PE653 Circuit Schedules 0x04 through 0x12 The PE653 allows the user to configure whether or not there will be scheduled ON and OFF times created to turn a circuit ON OFF during a 24 hour period Each circuit can have up to 3 scheduled activation times applied to it Each scheduled ON OFF activation time MUST have a valid ON and OFF time assigned The ON and OFF times are 16 bit values and minutes from midnight where midnight equals 0 To configure this behavior issue a Configuration Set command with the e The parameterNumber byte set to one of the values 0x04 through 0x12 e The level byte set to four 4 e g a four byte value being sent e The configurationVa
13. r the 3rd of three possible ON OFF activation schedules for VSP Speed 4 VSP_MAX_PUMP_SPEED 0x31 Used to set the MAXIMUM speed the 4 VSP speeds can be set to FREEZE_CONTROL 0x32 Used to enable or disable freeze control support at the PE653 PE653 Operation Mode 0x01 The PE653 has several settings that modify the PE653 circuit behaviors and inter dependencies These settings and modes are defined in detail in the User manual You may use this Configuration parameter to set these modes To set the mode set the mode of operation issue a Configuration Set command with the The parameterNumber byte set to 0x01 The level byte set to two 2 e g a two byte value being sent The configurationValue1 byte set to the circuit or variable speed pump speed to activate when the Cleaner Booster pump needs to be active The valid settings for this field are one of the following Circuit or pump speed to use for Booster Cleaner operation configurationValue1 Booster Cleaner Functionality not supported 0x01 Circuit 1 used for Booster Cleaner 0x02 Variable Speed pump Speed 1 used for 0x03 Booster Cleaner Variable Speed pump Speed 2 used for 0x04 Booster Cleaner Variable Speed pump Speed 3 used for 0x05 Booster Cleaner Variable Speed pump Speed 4 used for 0x06 Booster Cleaner The configurationValue2 byte is used to indicate the following two pieces of information o Whether the installed pum
14. rget temperature and the FURNACE setpoint is used for setting the SPA target temperature The valid ranges for both of these setpoint types is 40 to 104 degrees Fahrenheit in 1 degree increments 1 7 SENSOR_MULTILEVEL Command Class The SENSOR_MULTILEVEL command Class is fully supported as documented in the Z Wave Command Class Specification for retrieving the current adjusted water temperature being monitored by the PE653 If the PE653 is in POOL mode the value returned will be the POOL water temperature If the PE653 is in SPA mode the value returned will be the SPA water temperature The value returned will be a one byte value of the water temperature in degrees Fahrenheit