Home

Manual 9009 och 9010

image

Contents

1. 4 Dial 2 The unit confirms with a short beep Hang up If the unit replies with two beeps try again Activate the thermostat with SMS 1 Activate the thermostat function by sending an SMS with the following content ABCD 2 D where ABCD is your personal PINCODE D is the desired temperature 19 Deactivate the thermostat with SMS 1 Deactivate the thermostat function by sending an SMS with the following content ABCD 2 where ABCD is your personal PINCODE 20 Power supply Connecting power supply and charging Ontech 9030 can be power supplied in different ways 1 Connecting to a main power socket 2 With a 12 V accumulator The accumulator is connected with the cable to the jacket on the under side pin 12 and G Be careful to get the polarity right otherwise the unit can be damaged If the the accumulator is connected on the same time as the unit is connected to the main power socket the accumulator will be chargesd The accumulator acts like a backup battery in case of main power failure WARNING Manganese batteries or other not rechargeable batteries may not be used Decrease power consumption In order to decrease power consumption you can turn off the short range radio if it not is used The power consumption will then decrease with about 10 mA The short range radio is not used if there is no extra relays Ontech Relay 9010 or wireless alarm detectors Low battery Ontech GSM 9030 will
2. Check that the PINCODE is deactivated See page 6 e Check that the position of the SIM card in the unit is correct e Check the SIM card in a mobile phone in order to check the SIM card The green lamp is flashing on Ontech GSM 9030 No connection with the GSM network e Check if the area is covered by using the SIM card in a mobile phone e Check that the antenna is correctly mounted e Test with another SIM card The unit has no contact with extra units or wireless alarms Different radio channels e Check so all units in a system has the same radio channel See page 23 Ontech GSM 9030 has no contact with an individual extra unit Out of radio range e Check by moving the extra unit closer to the master unit e Check that the extra unit has a unique ID See page 23 e Place one more extra unit in the middle of the distance between the slave unit that lost contact and the master unit The unit do not react on SMS Wrong mobile number e Check that the mobile number is correct Wrong PINCODE e Check that your PINCODE is correct The easiest way to do this is to call up the unit from an ordinary telephone and enter the PINCODE and then If the PINCODE is correct the unit will reply with a beep If not the unit will hang up 31 Technical specifications GSM GSM subscription Relay Serial interface Short range radio Alarm inputs External power supply P
3. 2 if you want the alarm when the temperature rises above 5 degrees C The unit will send an SMS alarm to all the telephone numbers on the alarm list if the temperature drops below rises above 5 degrees C The function is deactivated by removing TEMP contact from the SIM card Setting alternative trigging temperature for the temperature alarm You can set an alternative temperature of your choice for the temperature alarm The alarm does not have to be acknowledged The unit cannot send another temperature alarm before it has changed more than one degree from set alarm temperature If the alarm is set to alarm when it drops below temperature X it will not send another alarm before it has risen above X 1 degrees If the alarm is set to alarm when it rises above temperature X it will not send another alarm before it has dropped below X 1 degrees Create a new contact and name it DEGREE i Write the alarm temperature in the telephone number field If the alarm temperature is below zero degrees Celsius add zero 0 before the temperature For example minus 7 degrees C is written as 07 Create a new contact and name it TEMP i In the telephone number field write 1 if you want an alarm if the temperature drops below the alarm temperature given in DEGREE or write 2 if you want the alarm when the temperature rises above the alarm temperature The unit will send an SMS alarm to all the telephone numbers o
4. Indicates the set temperature for the thermostat function If thermostat not is activated the message is Tstat OFF Acknowledge an alarm When an alarm detector has trigged the alarm it has to be acknowledged before the unit can send another alarm Temperature alarms GPS fence alarm and power fail alarm do not have to be acknowledged Acknowledge an alarm manually Press the button on the front of the unit at least once Note that also all alarm from the extra relays Ontech 9010 will be acknowledged Acknowledge an alarm with a telephone 1 Call up the unit Be sure you use tone mode on the telephone 2 The unit answers with a beep 3 Press your PINCODE and then Example 1234 16 If the PINCODE is correct the unit replies with a beep If it is not correct the call is disconnected Call again and try 4 Acknowledge the alarm by pressing the buttons 9 The unit replies with a beep Hang up the receiver If the unit replies with two beeps try again Also alarms from extra relays Ontech 9010 will be acknowledged Acknowledge an alarm with SMS 1 Send an SMS to the unit with the following message ABCD 9 ABCD is your PINCODE Also alarms from extra relays Ontech 9010 will be acknowledged Temperatur Temperature sensors Ontech GSM 9030 will by default use the internal temperature sensor for controlling and alarming The accuracy is 3 degrees C The internal temperature sensor is also affected b
5. lt indicates if the unit alarms when the temperature drops perature gt indicates if the unit alarms when the temperature rises perature Temp sens and thermosta sensor Ver Indicates which temperature sensor that controls alarms t INT internal sensor EXT den external Shows software version Useful when contacting support 25 Commands This description is valid both for telephone button and SMS text Command Explanation ABCD All telephone calls and SMS starts with your personal PINCODE of 4 digits When writing this symbol you are sending a command to the unit Thus the symbol ends a command If you have misspelled you can use this symbol to restart the command This symbol is used as a separator inside a command 1 N Used to activate a relay N the ID of the unit O N Used to deactivate a relay N the ID of the unit 1 N T Used to activate a relay with timer function N the ID of the unit And T the number of hours you want the relay to be active 2 Used to turn off the thermostat function 2 D Used to turn on the thermostat function 0 29 degrees C 7 1 Used to turn on the alarm function 7 O Used to turn off all alarms valid for all alarms except low battery alarms 8 Status SMS request 8 1 Request for GPS data 8 2 Request for SIM card settings 94 Used to acknowledge alarms e All SMS must begin with your personal P
6. 12V The connection cable has a connector in one end that fits in the jacket Switch from Normally Open to Normally Closed mode Locate the DIP switch see Fig 1 Factory default for switch 1 is OFF This mean the alarm inputs are set to NO mode The unit sends an ALARM A if connectors A and 12 are connected and ALARM B if connectors B and 12 are connected If DIP switch 1 is set to ON the mode is switched to NC The unit sends ALARM A if connectors A and 12 are disconnected and ALARM B if connectors B and 12 are disconnected 12 Suggestion for connection of alarm detectors in Normally Open NO mode Givare A Givare B Suggestion for connection of alarm detectors in Normally Closed NC mode 12 gt Ww eT Givare A Givare B Wireless alarm detectors Ondico AB will market wireless alarm detectors These can be easily connected to work together with Ontech GSM 9030 Up to 7 different detectors can be connected On Ondico website www ondico se we will inform more about this 13 Delayed activation of alarm detector Sometimes it can be desired to delay the activation of an alarm detector This is for example when you want to go inside the house and deactivate the alarm before it sends alarm messages Program the SIM card see page 7 as follows 1 Create a new contact Name it DELAYX X is the ID of the alarm
7. If another radio channel shall be used be sure to set the DIP switches 2 5 exactly the same in all units in the system 23 Reference SMS from the unit Alarm SMS Status SMS The alarm SMS and the status SMS are identical The alarm SMS is sent to all the telephone numbers on the alarm list You can reguest a status SMS by sending and SMS to the unit with the following content ABCD 8 where ABCD is your personal PINCODE You will immediately receive an SMS as below You cannot request status from an ordinary telephone only with SMS Status SMS is only sent to the telephone that requested the status Example Explanation Ontech9030 Asterisk means alarm function is turned on Alarm lab 3b Indicates all alarms that have been activated since the last acknowledge The number indicates the units ID number Ontech 9030 is always no 1 and the others refer to the extra units ore wireless alarm detectors connected Note that these inputs not can send an alarm again before the alarm has been acknowledged Inputs 1b Indicates the alarm input that still is activated In this example the SMS means that inputs 1a 1b and 3b has been activated since the last acknowledge and that input 1b is still activated Units 1 3 4 Indicates the units communicating with the Ontech GSM 9030 Unit number 1 is always Ontech GSM 9030 The other numbers refers to the extra relays Ontech 9010 connected An
8. Power supply wsceesseesseeee siai mei 21 Connecting power supply and charging eissa NRR 21 Decrease powerconsut PIOTR siere ieran a e EA E EA ded n s n 21 LOW DATE otor o R A A A O E T 21 Short range radio extra relayS esseesscessccssccssccosesosceosecosoeosecosocoseeosoeoseooseeoseeoseeoseeoseeose 23 Referent visa cicsvasencuvsccstiacecsdsvccsesdceinessusasdcecdossdensatses avescaueessbusyleseducsvaveseusssovevsdecssssedesecdusvsvecses 24 SMS from the Unit ainaani ai aAa diatonick 24 Alarm SMS Status SMS bo boro teto zlo ao R P E e 24 SMS about power SUPPLY ccssssssssssssessnssessssesoussssssssessssssnsssusssssusssesusssssusssseussssossesoussesossssoee 25 SMS Showing the SIM Card SETTINGS tone 25 COMMA OR R O o 26 Push OUO Naa AERO OSD BRA oo o dona o o 27 The r DS se sectsconesstsccovessntavedvsavssbececacoseapbtbacecsvtsdeusasebbesbeossustesssses bad bird d AA ONA 27 We DIP SWite Noob hk BA OBA odb Bo bo O o db ono 28 Tipp rE A E E NE E EAE PEE n oba Samos EE EE A EEA 29 Troubble shooting sccsecsscssssesosorsescsessesssorcrsecesossesesetossecteessesesorcetecssonsedeseroesesesessesesesorsecesoeseses Technical specifications Declaration of conformity Declaration of conformity 4 Overview Ontech GSM 9030 is a combined remote relay and an alarm caller and is communicating over the GSM network The cabinet is made for indoor use The unit is powered by plugging it into a main pow
9. alarm at low battery when connected to accumulator and NOT to main power socket Ifthe voltage between connector 12 and G drops below 12 Volt an SMS will be sent to all telephone numbers on the alarm list with the following content Charge battery If the voltage between connector 12 and G drops below 11 Volt an SMS will be sent to all telephone numbers on the alarm list with the following content Battery empty The low battery alarms do not need to be acknowledged 21 Important If there has been a low battery alarm the unit has to be restarted or the voltage must rise above 12 5 V before it can send a new low battery alarm 22 Short range radio extra relays Ontech GSM 9030 has a 2 4 GHz short range radio This is used to communicate with extra relays Ontech Relay 9010 and or wireless alarm detectors If the short range radio not is in use it is recommended to turn it off in order to lower the power consumption Do this by setting DIP switch number 6 to position ON see page 2il In a system with one Ontech GSM 9030 and one or more extra relays or wireless alarm detectors all has individual ID numbers Up to 8 different unique numbers can be used 1 8 Ontech GSM has always number 1 With the DIP switches 2 5 the radio channel for the short range radio is set In Ontech GSM 9030 as well as in extra relay Ontech Relay 9010 and the wireless alarm detectors these DIP switches are delivered in position OFF
10. the relay with timer function The relay can be set to be activated during a preset number of hours 1 99 Press the buttons as follows 1 1 T T the number of hours you want the relay to be active The unit confirms with a beep If there are two beeps try again After you have made one operation you can directly continue with another operation without calling up again When you have completed all operations then hang up 10 Control the relay with SMS 1 Activate the relay send an SMS to the unit with the following text ABCD 1 1 where ABCD is your personal PINCODE 2 Deactivate the relay send an SMS to the unit with the following text ABCD 0 1 where ABCD is your personal PINCODE 3 Activate the relay with timer function The relay can be set to be activated during a preset number of hours 1 99 Send an SMS with the following text ABCD 1 1 T where ABCD is your personal PINCODE T the number of hours you want the relay to be active Tip Instead of the symbol you can use all letters uppercase or lowercase on button 7 p q r Ors Instead of the symbol you can use all letters uppercase or lowercase on button 9 w x y OF zZ Tip If you not are sure about the settings of the unit you can request a SIM card setting SMS see page 25 The position of the relay after a power failure If there is a power failure and the relay is activated it will change to deactivated position When the power retu
11. you must enter each time you contact your Ontech GSM 9030 5 Goto Optional programming of the SIM card if you want special functions or 6 Turn off the mobile phone and remove the SIM card Go to to Installation of PMD the unit see page 9 Fel Bokm rket r inte definierat Make sure that you save all information are on the SIM card and not only in the memory of the GSM telephone It can be necessary to open the contacts and copy to the SIM card from the memory of the telephone See the manual of the telephone Avoid to copy more contacts than necessary to the SIM card No quotation marks or slashes or similar shall be written just the text 6 Optional programming of the SIM card In order to use some of the function you want it can be necessary to program more contacts on the SIM card See below NB To be sure programming is made in a correct way you can check by reguesting an SMS with SIM card settings See page 25 Do this every time you have changed the SIM card settings 1 Create a send list for alarms see page 11 1 Create a new contact Name it SMSO note that 0 is zero and not the letter O 2 Enter the mobile phone number for the receiver of the SMS Save 3 The following contacts in the send list are named SMS1 SMS2 etc and the mobile numbers are entered All numbers from SMSO to SMS9 can be used in total 10 different numbers 2 Set delay for activation of alarm detector DELAY se
12. INCODE e It is possible to send multiple commands in the same SMS or telephone call The symbol separates the commands e When operating with a telephone call all commands are confirmed with a beep Two beeps indicate a failure Try again e Instead of the symbol you can use all letters uppercase or lowercase on button 7 p q rors e Instead of the symbol you can use all letters uppercase or lowercase on button 9 w x y or z 26 Push button One push at the button activates or deactivates the relay One push is also used to manually acknowledge an alarm Push and hold for 5 seconds to turn on turn off the unit if there is an backup battery connected One push turns of thermostat function if activated The lamps On the front of the cabinet there are two lamps one red and one green GREEN LAMP Flashing Flashes when establishing connection with GSM network during start up On no flashing The unit is turned on and has contact with GSM network RED LAMP On no flashing The relay is activated Off The relay is deactivated Flashing One alarm has been activated and is not acknowledged RED AND GREEN LAMP Both are flashing SIM card is missing or Pincode on SIM card is not deactivated See page 6 27 The DIP switch The unit has 8 DIP switches see page Fel Bokm rket r inte definierat The functions of the switche
13. Ontech GSM 9030 g A GSM 9030 Users Manual Welcome Thank you for choosing Ontech GSM 9030 We hope that the product will satisfy your needs and that you will find this manual easy to handle and that it guides you in an appropriate way If you want to learn more please visit our web site at www ondico se where you can find more information Questions can be directed to support ondico se SMS text will be shown with gray background and bold text for example 1234 1 0 Also the buttons to be pressed when using a telephone in tone mode not pulse is shown in this way Text in italic indicates a menu in your mobile phone for example Contacts Quotation mark shall never be written in the contacts it is used in this manual only in order to separate the commands from other text This version of the manual is valid for all units with software version 005 or later To check the version of your unit please refer to SMS showing the SIM card settings on page 31 Ondico AB is not responsible for damages that may occur due to incorrect use or if the product does not work as desired s Content OVervieW RE EEA A E A EEEE AA EEE 5 Contentin package mvsenoreinionimena i a 6 AE a Te PEE A EE E E A sauessadeesubscdecdueses vsosasosasstebssossessdesicssueseseets 6 Necessary programming of the SIM Card essin a EA A 6 Optional programming of the SIM Card insidan ian 7 Back side cover removed 43 d
14. See page 25 Do as follows 1 Send an SMS to the unit with a request of the SIM card setting Write ABCD 8 2 where ABCD is the PINCODE you have programmed to the SIM card 2 The unit replies with an SMS with the settings Testing the unit When you have installed the unit it is recommended to test the function Call the unit or send SMS to control the relay Test the alarm inputs if used Ask for status SMS to check temperature 9 Functions Remote relay With this function you can call the unit or send an SMS and activate or deactivate the 230V 16A relay Insert the unit in the wall power socket you wish Put the power contact of the device you want to operate in the power socket of the unit Control the relay manually You can activate and deactivate the relay by pushing on the button on the front When the relay is activated the red lamp is lit Control the relay with a telephone iP 2 3 Call the unit Be sure you use tone mode on the telephone The unit answers with a beep Press your PINCODE and then Exemple 1234 If the PINCODE is correct the unit replies with a beep If it is not correct the call is disconnected Call again and try Activate the relay by pressing the buttons as follows 1 1 The unit confirms with a beep If there are two beeps try again Deactivate the relay by pressing the buttons as follows 0 1 The unit confirms with a beep If there are two beeps try again Activate
15. asterisk after the number indicates that the relay is turned on If Ontech GSM 9030 loose contact with one of the extra relays unit its ID number will not be shown in the SMS Temp 24 24 2 Gives the temperature in degrees C The first number refers to the internal temperature sensor the second number refers to 24 will be written instead external temperature sensor if connected If not connected If there is an asterisk for example 24 2 before the number this indicates that the unit has sent a temperature trigged by this sensor Tstat 25 Indicates the set temperature for the thermostat function If thermostat not is activated the message is Tstat OFF SMS about power supply The SMS sent to alert about the power supp y are as follows Content in SMS Meaning Charge battery Is sent when voltage is dropping below 12 Volt Battery empty Is sent when voltage is dropping below 11 Volt SMS showing the SIM card settings If you want to control the settings of the SIM card you can request an SMS that shows most of the SIM card settings Send an SMS to the unit with the following content ABCD 8 2 where ABCD is your personal PINCODE You will immediately receive an SMS as below Content Exlanation Ontech 9030 Asterisk means alarm function is turned on Alarmrelay Alarmrelay function ON or OFF Tempwatch below set tem above set tem
16. cal and shall be interpreted as follows Example Explanation Ontech9030 Asterisk means alarm function is turned on Alarm lab 3b Indicates all alarms that have been activated since the last acknowledge The number indicates the units ID number Ontech 9030 is always no 1 and the others refer to the extra units ore wireless alarm detectors connected Note that these inputs not can send an alarm again before the 15 alarm has been acknowledged Inputs 1b Indicates the alarm input that still is activated In this example the SMS means that inputs 1a 1b and 3b has been activated since the last acknowledge and that input 1b is still activated Units 1 3 4 Indicates the units communicating with the Ontech GSM 9030 Unit number 1 is always Ontech GSM 9030 The other numbers refers to the extra relays Ontech 9010 connected An asterisk after the number indicates that the relay is turned on If Ontech GSM 9030 loose contact with one of the extra relays unit its ID number will not be shown in the SMS Temp 24 24 2 Gives the temperature in degrees C The first number refers to the internal temperature sensor the second number refers to external temperature sensor if connected If not connected will be written instead If there is an asterisk for example 24 2 before the number this indicates that the unit has sent a temperature trigged by this sensor Tstat 25
17. dd td nn a a ainiaan 8 nstalatior oREREU NEB ices EV VK ar ie ord neh aoe o Poe none oe 9 Check the SIM Card Settings eee none nooo oo to eno no 9 Testing the A R tec neadaliviad EE NAAN 9 FUNC ONS nce A R ROA a desconsk ices N E N a 10 Remote relay apuaan n a paon A A n a bo diseo o d bo don 10 Control ther la Ma eal e ai E here aan SV aen aaa oe 10 Control the relay with a telephone u essssssesesuseeseesuseeseesnsesusseiasetnsssiasesnessiaseiaseeiaseiastenetee 10 Control the relay With SMS ssssssesssesuseessesuseesseiasesseeiasetusesiasetnsesiassinsesiaseiasttseeiastieeeetee 11 The position of the relay after a power failure sssssssvsssssssssssesesevorosstsosososesesosenonststsososenoronennstseses 1 PATTIE Pze neces tanci encanta aaa dose n ora orale lt DY alan o o dob adios odb 11 Wired alariga a AOE OAE EN AN AN AN AAEN 12 Wireless dlarinyGetectons cscs czds goto ition z i n a E end OANA 3 Delayed activation or alarn GETE nepsi a e E a E E EAA A 4 Activation of relay when alarming Alarmrelay 14 T rmoff onsth Ala iun tO Mine aA aa Ea E AR 4 WER TE Unni NaN e a AT decent hedtts ai 5 ACKNMOWED GE arial AL cessecisscsstcsssscsciscsunestinesunecsneiobeclseesinestsnsinesanactiossanacsbasinslettinevvsectseeasen 6 A a Ola ole ieies GSR RVS BEOS O B bad eo 7 SMpPerat re senson zzz Sn EAAS A bc8 KA ro o ooo oD sat non 17 T M PERALUT EA ATR zz ode er revere aE SS KD reo o doj 7 thermostat tinei Misaia ESMEDIA PO oa oo 9
18. detector you want to delay values of 1 8 are permitted i Write the numbers of seconds you want to delay in the telephone number field Example You want alarm detector with ID no 6 to be activated with a delay of 45 seconds In the name field of the contact write DELAY6 and in the field for the telephone number write 45 Activation of relay when alarming Alarmrelay This function activates the relay when the unit is alarming This function is useful if you for example have an alarm detector that alarms when water level is too high the relay is activated and turns on a pump e The function is activated by adding a contact on the SIM card and name it ALARMRELAY In the telephone number field write 1 see page 8 e The function is deactivated by removing the contact from the SIM card Turn off on the alarm function Each time you start up Ontech GSM 9030 the alarm function is turned on 60 seconds after the green lamp has stopped flashing This delay is because you shall have time enough to move away from the alarm detectors compare with an ordinary alarm If you do not want the alarm function to be active you can deactivate it If you do not have any alarm detector connected you do not have to think about this Turn off on the alarm function with a telephone 1 Call up the unit Be sure you use tone mode on the telephone 2 The unit answers with a beep 3 Press your PINCODE and then Example 1234 If t
19. e page 14 1 It is possible to set a delayed activation for an alarm detector This is for giving you time to deactivate the alarm before the unit is sending an alarm 2 Create a new contact Name it DELAYX X is the ID of the alarm detector you want to delay values of 1 8 are permitted i Write the numbers of seconds you want to delay in the telephone number field Example You want alarm detector with ID no 6 to b activated with a delay of 45 seconds In the name field of the contact write DELAY6 and in the field for the telephone number write 45 3 Activate the temperature alarm TEMP see page 17 1 Create a new contact and name it DEGREE i Write the alarm temperature in the telephone number field If the alarm temperature is below zero degrees Celsius add zero 0 before the temperature For example minus 7 degrees C is written as 07 2 Create a new contact and name it TEMP i In the telephone number field write 1 if you want an alarm if the temperature drops below the alarm temperature given 7 in DEGREE or write 2 if you want the alarm when the temperature rises above the alarm temperature Set active temperature sensor EXTTEMP see page 17 1 If you have an external temp sensor optional and you want it to control the temperature alarm and thermostat you have to activate it Create a new contact and name it EXTTEMP i Inthe telephone number field write 1 Ac
20. er wall socket Remotely controlled by telephone call Alerts and temperature and power fail s or SMS via SMS Relay230V 16A Has a timer function Can be programmed to remember position after a power failure Two alarm inputs for corded alarm detectors Can be set to NO or NC Can be programmed to activate relay when a Internal temperature sensor reports te External temperature sensor with high arms mperature accuracy is optional Alerts if the temperature falls below or rise above alarm temperature Thermostat function temperature reg ulates the relay Can control extra relay units Ontech 9010 via short range radio 5s Content in package e Ontech GSM 9030 e Antenna e This manual e Connection cable Get started In order to use the unit you must have a SIM card for a GSM mobile telephone and access to a mobile phone Cash card can be used The installation is made in three simple steps 1 Programming the SIM card 2 Physical installation 3 Test of the unit and its functions Necessary programming of the SIM card Insert the SIM card in a GSM mobile phone Deactivate the PINCODE function See the user manual of the mobile phone Delete all old contacts from the SIM card if there are any Choose Contacts in the mobile phones menu a Create a new entry Name it PINCODE b In the field for telephone number enter your personal four digit number This number is the PINCODE
21. ercase on button 7 p q r Ors Instead of the symbol you can use all letters uppercase or lowercase on button 9 w x y OF Z Checking SIM card settings If you not are sure about the settings of the SIM card you can request an SIM card setting SMS see page 25 Status SMS If you not are sure about the settings of the unit you can ask it for a status SMS See page 24 To long distance between Ontech GSM 9030 and Extra relays or wireless alarm detectors A built in function in all Extra relays and wireless alarm detectors is a radio repeater This means that each extra unit increases the working range with about 30 meters If one extra unit is out of range another extra unit can be connected somewhere between the 29 extra unit that is far away and Ontech GSM 9030 The extra unit will link the other two units together Check if the extra unit Ontech GSM 9030 has contact with the master unit One push of the button on the extra unit Ontech Relay 9010 switches the relay but is also sending information about this to Ontech GSM 9030 This unit acknowledges back that it has received the information During this process the red lamp on the extra unit will flash The process shall not take more than 3 seconds if more the extraunit probably lost contact with Ontech GSM 9030 30 Troubble shooting Symptom Reason Both the red and green lamp is flashing on Ontech GSM 9030 The unit cannot read the SIM card e
22. he PINCODE is correct the unit replies with a beep If it is not correct the call is disconnected Call again and try 4 Turn off the alarm function by pressing buttons 14 7 0 The unit replies with a beep Hang up the receiver If the unit replies with two beeps try again 5 Turn on the alarm function by pressing buttons 7 1 The unit replies with a beep Hang up the receiver If the unit replies with two beeps try again Turn off on the alarm function with an SMS 1 To turn off the alarm function send an SMS with the following message ABCD 7 0 where ABCD is your PINCODE 2 Turn on the alarm function again by sending an SMS with the following message ABCD 7 1 where ABCD is your PINCODE Turn off on the alarm function with the remote control Ondico AB will start to sell a remote control This is used to turn off on the alarm More information will be published on our web site www ondico se Tip If you want to know if the alarm is turned on or off you can check this by requesting a status SMS from the unit see page 25 When the alarm is turned on there is an asterisk before the name Ontech9030 It looks like this Ontech9030 When the unit is alarming Alarm list When an alarm is activated an SMS will be sent to all mobile telephone numbers on the alarm list How to create this list see page 7 Up to ten different persons can be alerted Alarm SMS Alarm SMS and Status SMS looks identi
23. n the alarm list if the temperature drops below rises above the set alarm temperature The function is deactivated by removing TEMP contact from the SIM card 18 Thermostat function If an electrical radiator is connected to the relay the unit can be used as a remote thermostat controller By programming the desired temperature the unit will scan the temperature and activate the relay and thus turn on the radiator if the temperature drops one degree C below the set temperature The surrounding air will be warmer and when the temperature rises one degree C above the set temperature it will deactivate the relay turning off the radiator First connect the radiator to the relay Activate the thermostat from a telephone 1 Call up the unit Be sure you use tone mode on the telephone 2 The unit answers with a beep 3 Press your PINCODE and then Example 1234 If the PINCODE is correct the unit replies with a beep If it is not correct the call is disconnected Call again and try 4 Dial 2 D where D the desired temperature The unit confirms with a short beep Hang up If the unit replies with two beeps try again Deactivate the thermostat from a telephone 1 Call up the unit Be sure you use tone mode on the telephone 2 The unit answers with a beep 3 Press your PINCODE and then Example 1234 If the PINCODE is correct the unit replies with a beep If it is not correct the call is disconnected Call again and try
24. ower consumtion Temperature range Certified GSM 900 1800 All kinds also cash card 230V 16A Special for GPS adapter Freguency 2 4 GHz Power output 1 mW Activated either by NO or NC mode Maxi 50 V 5 mA 9 24 V AC DC Nominal lt 0 5 W Max 4 W 20 C to 40 C Compliance EMC LVD and R amp TTE directive 32 Declaration of conformity Ondico AB Datav gen 14A 436 32 Askim Sweden hereby declares that the product Ontech GSM 9030 is in conformity with the provisions of the Radio amp Teleterminal directive R amp TTE 1999 5 EG 33 34 35 www ondico se SEE CE 078001 NJ al 0S0SL
25. rns it will remember the position it had before the power failure If this is not desired please set DIP switch 8 to position ON Alarm Ontech GSM 9030 can alarm in many different ways All alarms are sent as SMS to the telephone numbers on the alarm list see page 7 This SMS is identical to the status SMS The unit can be programmed so the relay activates when there is an alarm see page14 Wired alarm Two alarm inputs where alarm detectors can be connected Can be set as Normally Open NO or Normally Closed NC 11 Wireless alarm Ondico AB will start to sell different wireless alarm units which communicate with Ontech 9030 Up to 7 different alarm detectors can be connected The wireless alarm detectors planned are A Motion detector B Magnet switch Alarm box and C Emergency Alarm button Also a remote control to turn on off the alarm will be offered Temperature alarm The temperature alarm is trigged if the temperature rises above or drops below the preset alarm temperature See page 17 Battery alarm The unit alarms if the backup battery needs to be charged or if it is empty Wired alarm Connect an alarm detector When an alarm detector is activated it will either close or open an electric circuit It can be a magnetic switch detector a level detector a motion detector or any other kind of sensor The jacket on the under side has the following markings G Ground A Alarm input A B Alarm input B 12 Voltage
26. s are as follows DIP switch Function no 1 OFF Alarm A and B are set to mode Normally Open ON Alarm A and B are set to mode Normally Closed These four switches are used to set the radio channel If extra relays Ontech Relay 9010 or wireless alarms are used in a system all units must have the same radio channel U 4S Ww rm settings 6 OFF Short range radio turned on ON Short range radio turned off 7 Not in use 8 OFF The relay will remember position in case of power failure ON OFF The relay will not remember position in case of power failure Position OFF on the DIP switches is downwards compared to the text on the switch All switches are set to OFF as factory default 28 Tip Cash card If you are using SIM cash card be aware that many network operators demands you are sending at least one SMS or make one call every year Some also demands you refill at least once a year Check with your operator Multiple commands in the same SMS or call It is possible to execute multiple commands in the same SMS or call The sign separates all the command lines If you for example want to acknowledge an alarm but also want to activate the relay yOu press ABCD 9 1 1 All individual commands will be replied with a beep If there is a fault the unit replies with two beeps Using other letters for and Instead of the symbol you can use all letters uppercase or low
27. tive the function relay activates at alarms ALARMRELAY see page 14 1 Create a new contact and name it ALARMRELAY i Inthe telephone number field write 1 Back side cover removed Temp sensor contact SIM Card holder DIP switches 8 Installation of the unit 1 Remove the cover door on the back of the unit Use a small screwdriver 2 Install the SIM card see picture a The upper part of the SIM card holder is moved to left until you hear a click b Fold up the upper part of the SIM card holder c Place the SIM card in the upper part The cut corner of the SIM card shall be positioned in the upper right corner when the upper part of the card holder is folded back d Fold back the upper part e Lock the upper part by moving it to the right until you hear a click 3 If an external temperature sensor shall be used connect to Temp sensor contact Replace the cover door 5 Insert the unit in a power socket a The green lamp starts flashing for about 45 seconds This indicates that the unit is searching an GSM network b Finally the green lamp is lit The unit is communicating with the GSM network and the unit is ready for use c If both the red and the green lamp is flashing this indicates i SIM card is missing ii The PIN code on the SIM card is not deactivated Check the SIM card settings It is recommended to control the SIM card setting after installation
28. y the relay If the relay is activated it will indicate 1 2 degrees higher than normal due to heat produced by the relay If you wish higher accuracy 1 we recommend you to purchase the external temperature sensor Ontech Temp Sensor 9020_002 Installation of external temperature sensor The external temperature sensor is connected to the temp sensor contact close to the SIM card holder In order to make place for the cable you must remove some material from the cover on the marked place where material is made thinner If you wish to use the external temperature sensor for controlling the thermostat and trigging the temperature alarm you have to program the SIM card for this purpose see page 8 Create a new contact and name it EXTTEMP and in the telephone number field write 1 NB The external temperature sensor is not delivered together with Ontech GSM 9030 It is optional Temperature alarm Default setting If the temperature alarm is turned on the unit will send an alarm if the temperature drops below 5 degrees C The alarm does not have to be acknowledged but the unit will not send another alarm before the temperature has reached at least 6 degrees C 17 The temperature alarm is not activated by default Activate the temperature alarm as follows 1 Create a new contact and name it TEMP In the telephone number field write 1 if you want an alarm if the temperature drops below 5 degrees C or write