Home
Installer`s and User`s Manual
Contents
1. UO 4S UO 4S CONFIGURING 7 UO 4S CONFIGURING In order to adjust UO 4S panel for particular application it is necessary to describe all its configuration parameters those fall into three groups which are UO 4S own parameters such as identification name number ID remote control password loop parameters entry and exit delays sounders and relay parameters System s owners or supervisors parameters such as phone numbers ways of notification transmission and their parameters and types of reports to be transmitted TM Key parameters The adjusted values of configuration parameters are storied in the panel non volatile memory The panel can be configured by several ways The best way to program the UO 4S panel is to connect it to a computer by means of cable provided and to apply the program UPROG EXE of version 4 0 0 906 or above The first and second groups of panel parameters can also be configured through panel s SIM card inserted in any available cell phone TM key parameters can be adjusted by hardware The panel being configured in any way the panel top cover is opened Due to the panel is equipped with a tamper switch a fact of panel configuring can always be monitored by corresponding notification adjusting When configuring has been completed take care to close the panel top cover In order the event time within SMS notifications to be displayed correctly set the proper panel current time by remote S
2. Neverdsameg OOO For assigned alarm loops arming when opened and Auxiliary disarming when closed without delay 31 SECURITY SYSTEMS UO 4S GSM 4 ZONE ALARM PANEL Table 5 Designators of Relay Types Type of Executive Relay Program Ed Lock Control can be assigned only with single loop Confirmation NICO IE DEN Remote Control Ea Switch Off After Loop Disarming can be assigned only with single loop Example contact entry with Par1111 in Name field and 122223 60 30 3 in Phone number field will be considered as following UO 4S configuration This UO 4S panel is identified as 1111 The first alarm loop is configured to be Entry The rest alarm loops are configured to be Intruder The first relay has Lamp type The second relay can be controlled remotely The exit time will be 60 sec The entry time will be 30 sec The Contact ID messages transmission attempts number is 3 _ 7 2 2 Remote Control Password Adjusting Set the UO 4S remote control password by adding the following contact entry Name Phone Number Pas or Password XXXXX where XXXXX is five digital password Strictly five digits must be typed as a password otherwise remote control is disabled 7 2 3 Supervisors Descriptors Adjusting In order to describe supervisors to control the system remotely add the following contact entry for each supervisor descriptor five maximum Name Phone Number ANXXXXY
3. READY LED Indication Event or Condition Indicator Behavior TM key to reader first Three flashes touching in Operating mode LED flashes four times per 2 seconds 1 LEDs displaying key number in binary ae Then READY LED flashes once per a second 1 4 LEDs indicating loops being assigned with this key Flashes by red or yellow eight times per a second TM key to reader touching in Key Programming mode Flashes twice for 2 seconds 1 4 LEDs displaying the number of key being deleted Key deleting Nom Litsteady ss Litsteady ss eo with panel Sets of four times flashing twice per a second at communication has been lost 2 second intervals GSM signal has dropped Sets of two times flashing twice per a second at below normal value 2 second intervals Supply voltage is out of Flashes once per a second of switches off if 11 V 15 V range GSM coupling with panel has been lost too OPERATING Table 11 Panel 1 4 LED Indication Condition of a Loop Corresponding Indicator Behavior Loop is disarmed Associated LED is lighted off Associated LED is lighted on UO 4S Loop is broken or its arming failed Associated LED flashes twice per a second The arming command has Flashes twice per a second if loop resistance is been received but the arming out of normal range or flashes once per 2 delay has not been expired seconds if not Note Such indication is kept within 2 minutes since a broken loop
4. 900 1800 cellular communication channel The way of notification is user programmable and can be one of SMS messages voice messages Contact ID DTMF signals via corresponding modem or phone call without reply if user cell phone is eguipped with Caller ID option The UO 4S panel is also designed to be used within centralized security system monitoring a group of assets from Central Guard Station In such a case the UO 4S panel is suitable to transmit alarm and service messages from assets to the Central Station to verify centralized arming and to be used for scheduled patrol inspecting In order to monitor fire and intrusion conditions any detectors with dry contact outputs can be connected to the panel among them magnetic contacts photoelectric ultrasonic RF acoustic detectors with self contained power supply fire heat detectors and output circuits of other control and indicating equipment System arming and disarming can be carried out by several ways For local authorized arming disarming by means of Dallas Touch Memory keys an external TM reader should be connected to the UO 4S panel The UO 4S panel can be used to implement some home automation function such as remote switching on of home electric equipment light fixtures locks air conditioners kettles washing machines and so on UO 4S is to be powered by 12 VDC supply If RIP 12 uninterrupted power supply manufactured by Bolid Company is in use UO 4S panel is capable
5. Don t transmit TEST notification Notes 1 Phone Call and SMS message TEST can be sent only to A1 and A2 supervisors 2 TEST messages are not transmitted when all alarm loops are disarmed 3 TEST message sending period is counted from any last transmission to this supervisor 33 BOL D UO 4S GSM 4 ZONE ALARM PANEL 4 There must not be the same Name field in two or more entries 5 If you desire to receive different kinds of notification at a single cell phone you should record the corresponding number of entries with the same Phone Number field and different Name fields Example 1 Name A14444ss02 means that the first supervisor will receive SMS messages TEST every 2 hours Example 2 Name A11234gm10 means that the first supervisor will receive Voice alarm messages dealing with the first alarm loop All Voice messages dealing with the second loop except DESARMADO and ALARMA DE ENTRADA All Voice messages dealing with the third loop All Voice messages dealing with the fourth loop except ALARMA DE ENTRADA TEST messages are transmitted by Phone Call every 10 minutes 7 2 4 Loop Assignment Adjusting In order to assign alarm loop breaking with other panel executive and auxiliary equipment add the following contact entry Name Phone Number ShIXXXX YYYY0ZZZZ8SSSSIDDDD7BBBB6 where XXXX are the numbers of alarm loops assigned with relay K1 YYYY are the numbers of alarm loops assigned with re
6. Power Supply Connecting ss RE EER EE Ee ee AA RE EE Ee ee ee ee 24 6 7 SIM Card InstaMind issie N sk se dada 24 7 UO 4S CONFIGURING sisie E SOSEER sens SEGE ESEG EER GN US KERE KS ESE EE 25 7 1 UO 4S Configuring by Means Of PC sesse RE EE EE Ee EE EE 25 7 1 1 1 UO 4S Parameters Adjusting see is issie se bee se se be gee ee be ge be sk be ee ee 26 7 1 1 2 GSM Supervisor Parameters Adjusting ees ee ee ee 27 7 1 1 3 Notification Filter Adjusting ii ee ee ee ee ee 29 7 1 1 4 TM Key Parameter Adjusting ii ee ee ee ee 29 7 2 UO 4S Configuring by Means of a Cellular Phone ss 30 7 2 1 UO 4S Parameters Adjusting iii ee ee ee ee ee ee 31 7 2 2 Remote Control Password Adjusting iii ee ee ee ee ee 32 7 2 3 Supervisors Descriptors Adjusting iii ee ee ee 32 7 2 4 LoopAssidhmehtAadusind EE EA EG 34 7 2 5 Autoarming Adjusting aiii pda EE A IRA Ge EA ie 34 7 2 6 Siren Operating Time Adjusting cccocoococnccccccnnncccoonononononeninnncnos 35 7 2 7 Inner Sounder Operating Time Adjusting cccccccoooocccnonineninnncco 35 7 2 8 Configuration OVerwritiNQ ooccccccccccnncoccccnnncccnnnnconononononnnnnnnnnninos 35 7 3 Panel Current Time Setting aan 36 7 4 TM Key Hard ProgrammiNng u uses sesse ee esse ee ke ee ee ek ee ee N ee Ek AA ee EE ee 36 7 4 1 TM Master Key Hard ProgrammiNg iese sesse se ee ees see ee ee ee ee ee ee ee 36 7 42 TM Key Hard Program
7. armed by user with specified number Rotura del lazo lt N del lazo gt The specified loop resistance was out of range during arming or short open failure has occurred in this loop Incendio en la zona lt N del lazo gt Fire in this zone or Fire loop breaking Alarma en la zona lt N del lazo gt Intruder Alarm in specified zone Atraco en la zona lt N del lazo gt Panic button has been pressed in zone specified or breaking of Alarm loop La llave no autorizada Unknown TM key has been touched to UO 4S panel reader Programaci n The panel has just entered TM KEY Programming mode Confirmaci n de la guardia The Patrol Check circuit has been activated Fallo de alimentaci n de reserva 12 VDC voltage is out of range between 11 V and 16 V 19 UO 4S GSM 4 ZONE ALARM PANEL Voice Message Received Notification Recuperaci n de alimentaci n de 12 VDC voltage has been restored reserva Fallo de alimentaci n Mains power has failed more than 20 s Recuperaci n de alimentaci n Mains power has been restored Alarma de la entrada Breaking of armed Entry alarm loop Alarma de sabotaje The panel enclosure has been opened El sabotaje se ha recuperado The panel enclosure has been closed Reinicio Panel restart 4 7 3 Notification by Contact ID Messages If Contact ID protocol is selected in order to be transmitted through GSM channel the panel ID
8. insert the panel s SIM card into any available cell phone and select SIM CARD MEMORY option in phone settings 7 2 1 UO 4S Parameters Adjusting In order to define the name number of UO 4S panel itself the alarm loop types relay executive programs entry and exit delays and the number of attempts of Contact ID message transmission add the following entry to the phone contact list Name Phone Number ParNAME XXXXYY Z T W where NAME is a name or number to identify this panel while notification is sent It can consist from digits and letters the first symbol being no zero Its length can range from 1 to 7 symbols If Contact ID or Voice notification channels are in use the panel name has to contain only digits from 1 to 9 zero excluding XXXX are types in accordance with Table 4 of alarm loops from the first to the fourth as they are marked on panel PCB YY are types in accordance with Table 5 of the first and the second relays Z is an exit time arming delay in seconds from O to 255 zero meaning arming without delay By it is set to zero T is an entry time disarming delay in seconds from 0 to 255 zero meaning disarming without delay By default this one is set to zero W is a number of attempts of Contact ID message transmissions from 1 to 10 Table 4 Designators of Alarm Loop Types Loop Type Designation 0 Reseved EN Entry Zone with arming and disarming delay capabilities a mam Neerdsmed fs Fre
9. kQ value 14 Arm alarm loops They must enter ARMED status 15 Set alarm loop 1 resistance to the 17 kO value Ensure the loop having entered ALARM status 16 Inspect K3 contacts They must be closed 17 Disarm loops Set alarm loop 1 resistance to the 15 kQ value 18 Arm loops They shall enter ARMED status 19 Disarm loops Set alarm loop 1 resistance to the 17 kQ value 20 Arm loops Loop 1 shall enter ARMING FAILED status 21 Disarm loops 22 Repeat steps from 6 to 21 for loop 2 loop 3 and loop 4 23 Switch relay 1 remotely by SMS sending see section 8 6 4 1 24 Ensure K1 contacts are closed 48 UO 4S MANUFACTURER DATA 11 MANUFACTURER DATA ZAO NVP BOLID 4 Pionerskaya street Korolyov Moscow Region Russia 141070 Tel fax 7 495 777 40 20 7 495 516 93 72 E mail info bolid ru Web site http www bolid com 49 BOL D E UO 4S GSM 4 ZONE ALARM PANEL Warranty Manufacturer warrants its product to be in conformance with specification under normal transportation storage mounting and maintenance Manufacturer warrants UO 4S product to be free from defects in materials and workmanship under normal use and service for 18 months since putting it into operation but no more than 24 months since acceptance date below The reconservation period must not exceed 12 months In the event of in warranty failure the failed UO 4S should be brought back to the manufacturer supplied with its da
10. must contain only non zero digits The receiving GSM signal level should exceed a half of cell phone scale Table 3 Contact ID Messages Transmitted by UO 4S Contact ID Codes Notification dortal Quali Event Loop panel fier Code Number number Disarmed XXXX 18 1 401 X XX X Armed XXXX 18 3 401 X XX X Arming Failed XXXX 18 1 454 X X Fire Loop Trouble XXXX 18 1 373 X 0 X Fire XXXX 18 1 110 X 0 X Intruder Alarm XXXX 18 1 132 X 0 X Panic Alarm XXXX 18 1 122 X 0 X Unknown TM Key XXXX 18 1 406 0 0 X TM Programming XXXX 18 1 627 0 0 X TEST XXXX 18 1 602 0 0 X Patrol Check XXXX 18 1 999 0 0 X Low 12 V Voltage XXXX 18 1 302 0 0 X High 12 V Voltage XXXX 309 0 0 X 12 V Recovered XXXX 18 3 302 0 0 X AC Failed XXXX 18 1 301 0 0 X 20 UO 4S TECHNICAL DESCRIPTION Contact ID Codes Four digital Identi Quali Event Loop User panel fier fier Code Number Number number Notification AC Restored Entry Alarm Panel Tampering Panel Case Closed Panel Restart 4 7 4 Notification by Phone Calls The notifying by phone calls without replying is the least cost and least informative way It can be configured to mean only one event or event complex Such a way of notifying is available only if user cell phone is equipped with Caller ID option The panel is configured to transmit specified reports by Phone Call to pointed s
11. on for 4 seconds enabling the electromagnet lock opening Then the relay switches off and the lock is closed An exit button can be brought in such a relay circuit 4 3 3 Confirmation Relay Program This type of relay control is suitable for centralized security system Such a relay is switched when a user is arming assigned alarm loops by means of TM key Being turned on the relay switches in interrupted mode 14 UO 4S TECHNICAL DESCRIPTION once per a second The external light can be included in the relay circuit to indicate the relay switching The relay is switched off after remote confirmation from Security Station having been received or when all assigned loops are disarmed or at least one assigned loop has entered in Fire Alarm condition 4 3 4 Lamp Relay Program Such a relay is designed for external indicating The relay is switched on when at least one assigned alarm loop is armed and there are no assigned loops in Arming Failed status or Breaking condition If all assigned alarm loops are disarmed the relay is switched off If at least one assigned loop is in Arming Failed status or Breaking physical condition the relay switches in interrupted mode once per a second 4 3 5 Remote Control Relay Program This type of relay control is design to enable remote control of various devices connected to this relay circuit such as electromagnetic lock electric kettle conditioner radiator washing machine video came
12. sharp edge rounding places While removing the panel from its package on receipt inspect the panel PCB to be free from detached components and pinout defects Test the panel operability in accordance with technical algorithm discussed in section 10 1 The panel is to be mounted on walls or other suitable surfaces protected against atmospheric layouts mechanical damages and unauthorized access 6 2 TM Reader Connecting If the panel is to be controlled locally by means of TM keys an external TM reader must be connected as shown in Figure 3 2 and discussed in section 2 3 6 3 Alarm Loops Connecting Connect all necessary alarm loop circuits to the PCB terminal blocks marked as LUC from 9 to 16 All detectors have to be wired into alarm loop in series with 8 2 kQ resistances provided as shown in Figure 3 2 Fire heat detectors additionally have to be brought in circuit with 10 k resistance in parallel across it The possible number of devices to be included into each alarm loop is defined by user needs and technical restrictions for loop and wires resistance common loop resistance shall be within 2 to 15 kQ range and common wire resistance shall not exceed 100 Q for fire loop and 1 kQ for rest ones If Exit button is to be brought in a loop circuit it is included as shown in Figure 6 1 23 BOL D UO 4S GSM 4 ZONE ALARM PANEL Exit Button Intruder Alarm Loop 8 2 KOM Figure 6 1 Exit Button Wiring 6 4 Executiv
13. to detect AC line failures following by transmitting trouble notifications to authorized cell phone UO 4S panel is round the clock indoor operable UO 4S SPECIFICATIONS 2 SPECIFICATIONS UO 4S panel rev 02 is designed to be powered by 12 VDC supply the panel voltage consumption being from 10 2 to 15 V The operating temperature range is from 30 to 50 C The current rating doesn t exceed 80mA When transmitting messages and while registration in GSM network current consumption can short time increase up to 500 mA 2 1 Alarm Loops The maximum number of alarm loops with monitored detectors to be connected to the panel is four The input alarm loop voltage ranges from 6 to 12 V When short circuit failure has happened in any alarm loop other loops are kept being supplied as described above UO 4S restricts the electric current flowing through an alarm loop not to exceed 12 mA If intruder detectors are included in an alarm loop then wire resistance without regard to termination resistor must not exceed 1 kQ while leakage resistance between loop wires or between each wire and the earth must be at least 20 KO If fire heat detectors are included in alarm loop then wire resistance without regard to termination resistor must not exceed 100 Q while leakage resistance between loop wires or between each wire and the earth must be at least 50 kO 2 2 Relay Outputs The device is equipped with three executive relays one re
14. 1 egative and positive contacts to connect an alarm loop 2 LLIC1 10 N n LUC1 9 egative and positive contacts to connect an alarm loop 1 0B 8 KLIH 7 To connect a Patrol Check circuit 0B 6 To connect Knut and OB UO 4S contacts Knut 5 to OC and 0 V RIP 12 output contacts respectively B 4 A 3 Reserved 0B 2 12B 4 0 V and 12 V contacts to connect power supply 10 UO 4S TECHNICAL DESCRIPTION 4 TECHNICAL DESCRIPTION 4 1 UO 4S Functional Diagram The main functional nodes of UO 4S GSM 4 Zone Alarm Panel and interconnection between them are shown in Figure 4 1 Microprocessor supervises all system components by monitoring for alarm loops receiving and sending communication data through GSM module and controlling the internal sounder siren relay outputs and Touch Memory reader operations Power Voltage Internal Converter Antenna or External Antenna with Adaptor Indicators To GSM Indicator GSM Module Microprocessor External Indicato SIM Card Reader Reader Figure 4 1 UO 4S Functional Diagram 4 2 Zones to Be Monitored and Alarm Loops UO 4S GSM 4 Zone Alarm Panel is designed to monitor up to four different zones for fire or intruder conditions within protected area Zone is physically represented by an alarm loop with various detecting devices included 11 BOL D UO 4S GSM 4 ZONE ALARM PANEL UO 4S panel allows programming o
15. 2W 8K2 5 UO 4S to PC connecting cable TM key DS1990R F5 UO 4S can be supplied with external 900 1800 GSM antenna and GSM to FME adapting cable E ER O 5 2 Marking Each panel is supplied with marking as follows Manufacturer logotype Symbolic notation The year and the quarter of the manufacturing Accordance mark Factory serial number The external panel terminal marking corresponds to the PCB layout see 3 2 clause KEER RR N 5 3 Packing The panel along with component parts and maintenance documentation is packed into the carton box It is assumed to pack the panel into the proper container The boxes or containers are placed along with accompanying documents into the transportation packing Each transportation packing should be furnished by packing list contained information as follows 1 Manufacturer logotype 2 The identification designation and the number of products inside 3 The designation and the number of replacement components 4 Packager sign or stamp 5 The packaging date 22 UO 4S GETTING STARTED 6 GETTING STARTED 6 1 Panel Mounting Do FOLLOW the electrical installation operational and electrical safety code rules during the installation operation or maintenance of S2000 ASPT panel and communication lines and associated equipment Do SHUT OFF mains and backup power before installing the panel or repairing any failure Prevent the electric wire isolation from being broken at
16. MADO any or message about all loops being disarmed CONFIRMADO Patrol Check circuit is activated DC BAJA DC voltage is below 11 V DC ALTA DC voltage is above 16 V DC RECUPERADA DC voltage has been within normal range AC BAJA AC voltage has been out of range more than 20s AC RECUPERADA AC voltage has been OK more than 20s ALARMA de ENTRADA S1 nombre1 S2 nombre2 Breaking of armed Entry alarm loop APERTURA The panel enclosure has been opened CERRADO The panel enclosure has been closed REINICIO The panel has just been restarted Notes 1 If NN 1 15 then a loop was disarmed armed by means of TM key with NN number If NN 20 then a loop was disarmed armed by means of auxiliary loop closing opening if NN 21 25 then a loop was disarmed armed remotely by means of supervisor described with NN 20 number in panel configuration see section 7 1 1 2 2 If NN 1 15 then a loop was disarmed armed by means of TM key with a configured key name If NN 20 then a name field will be empty if NN 21 25 then name field will contain the name of a supervisor as it was assigned while being configured see section 7 1 1 2 3 When Fire loop has been recovering the USARIO part is not transmitted 4 Each notification is preceded by current time formatted as HH MM hours and minutes This timestamp to be displayed correctly set the panel current time remotely as described in sectio
17. MS command as explained in section 7 3 7 1 UO 4S Configuring by Means of PC Adjust UO 4S panel by means of a computer by doing the following Power on the computer with UPROG EXE installed Verify the version of configuration program is 4 0 0 906 or above Connect UO 4S to a COM port of computer by connecting cable provided Ensure the panel PCB jumper is set on Power the UO 4S on and run UPROG EXE Click button from the tool bar or select Dispositivo gt Leer configuracion de dipositivo commands 25 BOL D UO 4S GSM 4 ZONE ALARM PANEL When Buscueda de dispositivos window has been opened enter or select the PC COM port the panel is connected to into Puerto serie field and select Buscueda command When the list of the devices found at pointed COM port has been displayed select the UO 4S being configured and click Eligir button The configuration having been read the main UPROG window is opened Once the panel configuring has been completed save all settings by writing new configuration to UO 4S by means of Guardar la configuracion en el dispositivo command from the Dispositivo menu or from toolbar The sound signal will acknowledge the change saving The configuration having been set can be changed in future if necessary 7 1 1 1 UO 4S Parameters Adjusting In order to configure UO 4S parameters select Dispositivo tab First describe the object setting UO 4S parameters Enter the unique UO 4S identifier int
18. SECURITY SYSTEMS UO 4S GSM 4 Zone Alarm Panel revision 02 cme UO 4S READY 10 20 30 40 BOLD Installers and User s Manual SECURITY SYSTEMS UO 4S GSM 4 ZONE ALARM PANEL Table of Contents GENERAL o idad oe 6 2 SPECIFICATION Siurana 7 2 1 IMAN LOS ad ia 7 2 2 Relay OutDUIS is ee Re tess ace hw iene sete EE ek 7 2 3 Touch Memory Reader INDUt ss sesse RE EER AA RR EER EE ke AA RE EE EE 7 3 UOS DESIGNED Re ES N ene ER Se ee EE Re ee 8 3 1 Panel EighitIndiGator Ss Ee GE Ee ee Ge GE 8 3 2 Panel PCB and Terminal BlOCKS susse EER AA RR EE EE ER RR AA EE EE EE 8 4 TECHNICAL DESCRIPTION ese ees geseg a iaa 11 41 UO 4S Functional Diagram sade se ed ee ee de NE De SE EN 11 4 2 Zones to Be Monitored and Alarm LOODS usus ee ER EE EE 11 42 OOP TYPE MEE EE ta alah OSes ea 12 4 2 2 Physical A RE a Re 12 4 2 3 Loop Logic Status Control RR RR RR RR RR Re ee ee ee 13 424 LoopAuloafmING ike scant EG RA ER GE ED ee A ses 13 4 2 5 Local Arming and Disarming by TM KeYS iese ese ee ee ee ee 13 43 Relay QU IPUES A ee A GEE EE EE A EG ies 14 4 31 O A A 14 4 3 2 Lock Control Relay Program uie ee ee ee ee ee ee ee ee ee ee 14 4 3 3 Confirmation Relay PrograM esse ee ee ee ee ee ee ke ee ee 14 434 Lamp Relay Program Li N a a Ge 15 4 3 5 Remote Control Relay Program occcccccccccccocncccccnnnccccononononnnnnnnnnnnnns 15 4 3 6 Switch Off After Loop Disarming Relay Program iese se
19. TZZ PHONE NUMBER where A is the special initial symbol N is the sequence number of descriptor which can be from 1 to 5 This number must not be repeated from entry to entry XXXX is the sequence of message transmission parameters see Table 6 for loops from the first to the fourth Y points the way of notification transmission see Table 7 32 UO 4S UO 4S CONFIGURING T points the way of TEST message transmission see Table 8 ZZ defines the time period in corresponding units for TEST message transmission period PHONE NUMBER is supervisors cell phone number preceded by international code which notifications will be sent to Table 6 Message Transmission Parameters Meaning Don t transmit notifications concerning this alarm loop Transmit only alarm messages concerning this alarm loop Don t transmit DESARMADO and ALARMA DE ENTRADA Transmit all messages Transmit all messages except ALARMA DE ENTRADA Table 7 Notification Transmission Ways Notification by SMS messages Notification by DTMF Notification by Phone Call Notification by Voice messages Table 8 TEST Message Transmission Parameters Meaning TEST notification is transmitted by SMS every several hours from 1 to 250 hours TEST notification is transmitted by Phone Call every several hours from 1 to 250 hours TEST notification is transmitted by Phone Call every several minutes from 1 to 250 minutes
20. URING Next give the relay parameters in Rel 1 2 sections Select the required relay types in Tipo and assign each relay with loops zones whose breaking has to lead to the relay switching in Zonas The available relay programs are see 4 3 clause Gesti n de cerradura Lock Control Confirmacion Confirmation Lampara Lamp Gestion de exterior Remote Control Apagar al desarmar Switch Off After Loop Disarming Finally in Sirena y la biper interior section define the settings of the panel sound alarms if necessary Enter the siren sounding time from 1 to 255 seconds in Duracion de alarma field and assign the siren with alarm loops whose breaking has to be accompanied with external siren signaling in Zonas asociadas con sirena windows Similarly enter the internal sound alarm operating time in Tiempo func de biper field and couple the internal sounder with alarm loops whose breaking has to cause the internal sound signaling in Zonas asociadas con biper windows Zero set in Duraci n and Tiempo fields designates not sounding while value of 255 designates that sounding will not be terminated until the alarm loop will be disarmed 7 1 1 2 GSM Supervisor Parameters Adjusting In order to configure supervisor parameters select Tel fonos tab At the top part of the window having been opened there is a group of transmission parameters set by default The default values are defined for typical applications in order to keep
21. V RIP 12 output contacts respectively When mains power has dropped such a power control circuit is closed providing power trouble detecting Similarly when AC line has restored the power control circuit is recovered too Moreover the panel itself detects failures of a 12 V power supply and enables internal indicating and remote notification of supply voltage being out of range 4 6 Panel Operating Modes UO 4S GSM 4 Zone Alarm Panel operates in one of the following modes Operating Fire Alarm Lock Control Key Programming 4 6 1 Operating Mode The panel mode is considered to be Operating if all armed loop physical conditions are Norm see section 4 2 2 or if any alarm loop has been open or closed for no more than 250 ms 4 6 2 Fire Alarm Mode The panel enters Fire Alarm mode while any armed loop except auxiliary has been broken for more than 300 ms meaning an included detector having actuated Entry alarm loop enters Alarm condition since entry delay time having elapsed if it was not disarmed during this time If an actuated loop was assigned with the panel relay K3 and an external siren is connected to the relay output in question then such the siren shall be turned on in Fire Alarm mode If a relay output is configured as Confirmation see section 4 3 3 it is switches off in Fire Alarm mode until broken loop rearming 4 6 3 Lock Control Mode UO 4S panel provides control of an el
22. able at the toolbar will be as follows To read keys from a file Leer fichero de los cydigos de llaves To write the keys into a file Guardar el fichero de los cydigos de llaves To read keys from a device Leer las llaves de dispositivo To write the keys into the device Guarda las llaves en dispositivo To add a key Acadir un llave nueva a dispositivo P To delete the selected key Ee Borrar llave To begin with it is necessary to read keys from the panel if presented If there is no key programmed before it is possible to read keys from floppy disk by means of first tool if such a disk is available or to program a number of keys manually TM Master Key can not be created by software To program it follow the instructions of section 7 4 1 When Master Key has been programmed 29 BOL D UO 4S GSM 4 ZONE ALARM PANEL its descriptor is located within Key Table string with zero number on the computer screen ATTENTION When TM Master Key has been programmed all TM keys configured before are lost To add new TM key with arming disarming authorities vt Select Acadir la llave button from the toolbar ta Select Leer la llave button at right part of the screen and touch a TM key to the reader following in system prompt When the programmed TM key descriptor has appeared within the table select its specified loop arming and disarming authorities by double clicking on table cell located at the intersection of desi
23. and system notifications that can be transmitted if configured from UO 4S to an authorized cell phone as SMS messages Table 1 SMS messages transmitted by UO 4S Text of Notification SMS message Received DESARMADO Loops with numbers S1 S2 and with names S1 nombre1 S2 nombre2 specified by nombres have been disarmed by USUARIO NN nombre authorized user see notes 1 3 below ARMADO Loops with numbers S1 S2 and with names S1 nombre1 S2 nombre2 specified by nombres have been armed by USUARIO NN nombre authorized user see note 1 3 below obra S2 nombre The prompt to arm specified loops has failed EEE S2 nombre Short or open failure of specified loops INCENDIO FIRE at Fire alarm loops with specified numbers S1 nombre1 S2 nombre2 and names 17 SECURITY SYSTEMS UO 4S GSM 4 ZONE ALARM PANEL ALARMA S1 nombre1 S2 nombre2 Breaking of Intruder alarm loops with specified numbers and names PANICO S1 nombre1 S2 nombre2 Breaking of Alarm loops with specified numbers and names DENEGADO The unregistered TM key has been presented PROG The panel has entered Key Programming mode PRUEBA TEST message that is periodical automatic ESTADO ARMADO S1 S2 report about current loop logic statuses ESTADO The reply after remote loop status request see ARMADO 1 S2 or 8 6 1 Can be the list of armed loop numbers if DESAR
24. condition defining and report message generating Fire alarm loop physical conditions are defined depending on its resistance measured as follows 0 2 0 5 16 2kQ 140 17kQ 50kQ Short 5 Open Failure Breaking Norm Breaking Failure When a fire alarm loop has been broken fire heat detector has actuated FIRE INCENDIO message is generated If short or open failure has occurred in a fire loop then TROUBLE message ROTURA DE LA LINEA DE INCENDO is formed After fire loop having been restored ARMED ARMADO message is generated Entry Alarm and Intruder alarm loop physical conditions are defined depending on its resistance measured as follows 12 UO 4S TECHNICAL DESCRIPTION Norm Loop resistance is within 2 to 14 KO range and resistance deviations don t exceed 10 within a hour Breaking Loop resistance is less than 1 6 kO or more than 17 kQ or loop resistance value has jumped more than 10 of deviation When an Intruder or Alarm loop has been broken ALARM ALARMA message is formed When an Entry alarm loop has been broken after entry or exit delay expiring ENTRY ALARM ALARMA DE LA ZONA ENTRANTE message is generated Auxiliary alarm loop physical conditions are not defined with loop opening leading to arming and loop closing leading to disarming of assigned alarm loop 4 2 3 Loop Logic Status Control An alarm loop can get one of the three logical statuses which are Armed Di
25. ct ID ADEMCO is used Then select for each alarm loop in Parametros de transmisi n section the way for transmission of notifications specified below in 7 1 1 3 clause The notifications about each alarm loop conditions can be not transmitted to this supervisor at all or can be transmitted all or only alarm messages can be transmitted or all notifications except DESARMADO or ALARMA Finally in Nombre window type the system owners name which will be displayed in SMS messages being sent to other supervisors in case of remote arming and disarming 28 UO 4S UO 4S CONFIGURING The switch Permitir descolgar el tel fono is reserved 7 1 1 3 Notification Filter Adjusting Adjust the types of messages to be transmitted by UO 4S panel to its supervisors Select the Filtros de mensajes tab The table with message list down and supervisor list across will appear All types of available notifications are described in section 4 7 of this manual By default each cell in table is marked meaning that all types of notifications are available to transmit to all supervisors Double click left mouse key on those cells that are located at points of intersection of message that MUST NOT be transmitted and supervisor that MUST NOT be notified by corresponding message Such the cells will be empty 7 1 1 4 TM Key Parameter Adjusting Select Llaves tab in order to add or delete TM keys or to assign them with specified authorities The tools avail
26. d loops are broken add the following entry to the contact list Name Phone Number Sound YYY where YYY is the number of seconds you want the sounder to be switched on in case of assigned loop breaking The time value can range from O to 255 seconds with O meaning not sounding and 255 meaning the sounder will be switched on continually until alarm will be reset By default the sounder operating time is set to zero not sounding 7 2 8 Configuration Overwriting The configured parameters must be relocated from the SIM card to the UO 4S non volatile memory To do this 1 Power off the UO 4S panel and open the panel cover 2 Move the SIM card from the cell phone to the panel SIM card reader 3 Power up the panel and wait for 10 seconds until READY LED has terminated flashing 35 BOLD UO 4S GSM 4 ZONE ALARM PANEL 4 Enter TM Key Programming mode by touching the TM reader with Master Key The panel internal sounder shall doubly beep three times meaning Programming mode entering 5 Press and hold panel tamper switch for 10 15 seconds 6 Wait until UO 4S terminates beeping less than 1 minute 7 Replace the panel cover Note Write the configuration from SIM card into the panel memory only if the communication within GSM network is stable 7 3 Panel Current Time Setting Set the UO 4S panel current time as described in section 8 6 6 7 4 TM Key Hard Programming In order to program TM keys by hardware it is neces
27. e Devices Connecting Connect if necessary an external siren to panel K3 contacts 21 and 22 Connect the required executive devices to the contacts K1 and K2 17 20 in accordance with the connecting diagram shown in Figure 3 2 If the executive devices require more powerful switching equipment include such devices into the relay output executive circuit 6 5 Patrol Check Circuit Connecting Connect if necessary Patrol Check circuit as shown in Figure 6 2 OB Pin 8 KLIH Pin 7 Figure 6 2 Patrol Check Circuit Wiring 6 6 Power Supply Connecting Connect power supply leads to 12B and OV 1 and 2 respectively panel PCB contacts see Figure 3 2 If RIP 12 uninterrupted power supply is to be used connect its OC contact to the Knut 5 panel terminal and couple RIP 12 O V terminal with panel 0 B contact 6 in order to provide mains power control see section 4 5 6 7 SIM Card Installing In order to communicate with UO 4S panel by means of a GSM channel a cell phone SIM card must be located into the panel GSM module see Figure 3 2 Before installing inside the panel disable PIN CODE PROMPT SIM card setting by means of any available cell phone Verify the sufficiency of GSM network signal level at the place of panel location If two tone Contact ID protocol is assumed to be used in order to transmit notifications the GSM signal level must reach at least a half of the cell phone scale 24
28. easured value doesn t exceed 80 mA 3 Ensure READY indicator has lit within 1 minute after UO 4S powering up the external power voltage being out of 11 V 15 V range READY indicator shall flash once every 2 seconds 4 Program Master Key if not presented and a TM key for all alarm loop control as described in section 7 4 46 UO 4S MAINTENANCE UO 4S to PC Connecting Cable To External Antenna Touch Memory Reader D jo A N To Siren O a To Executive gt Devices Internal Antenna 1 kOhm gt To OC RIP 12 O GSM O READY O1 O2 O3 O4 Tamper Switch Se Bank of Resistance Figure 10 1 UO 4S Testing Wiring Diagram 47 BOLD UO 4S GSM 4 ZONE ALARM PANEL 5 Configure all alarm loops as Intruder as described in chapter 7 6 Connect a resistor bank into the first alarm loop and set 1 8 kQ resistance value 7 Arm alarm loops Ensure alarm loop 1 has entered in ARMING FAILED status by observing indicator s behavior 8 Configure UO 4S relay types as Remote Control for relay 1 and Lamp for relay 2 as described in chapter 7 9 Disarm all alarm loops Ensure all loops having entered DISARMED status 10 Set alarm loop 1 resistance to 2 kQ 11 Arm alarm loops and ensure their having entered ARMED status 12 Inspect K2 contacts They must be closed 13 Disarm all alarm loops and set alarm loop 1 resistance to the 8 2
29. ectromagnet lock connected to a Lock Control programmed relay output While disarming the loop assigned with this relay or while pressing on Exit button included in this 16 UO 4S TECHNICAL DESCRIPTION loop being disarmed the relay turns on for 4 seconds allowing the lock to be released 4 6 4 Key Programming Modes The panel can be switched in two special modes those are TM Master Key Programming mode designed to program special Master TM Key used to enter and exit Key Programming mode by touching TM reader and TM Key Programming mode designed to program by hardware a number of TM keys used to arm and disarm a system The panel is switched to these modes as described in section 7 4 4 7 Remote Notification The UO 4S panel provides alarm and trouble remote GSM notifications by means of four different ways which are SMS voice messages Contact ID DTMF signals via special modem and phone calls without replying if user cell phone is equipped with Caller ID option Up to 5 system owners or supervisors can be notified by a panel A panel can be configured to send automatically periodical reports about loops armed currently to one of two pointed supervisors The types of notifications being sent to panel supervisors can be flexible selected from a group of available ones for each alarm loop and each supervisor separately 4 7 1 Notification by SMS messages In Table 1 following is the list of all available alarm
30. ening and closing respectively and by TM key to reader touching This section explains in details how to arm and disarm system zones by means of TM key to reader touching Operations described below are enabled only if the key presented has been registered by UO 4S panel with authorities to arm and disarm specified alarm loop see section 7 1 1 4 The double touching method is implemented in order to arm and disarm system by means of TM key Since 30 seconds after first touching the loop statuses are being displayed by reader light indicator The second touching within this 30 second period leads to arming or disarming of loops assigned with this TM key 8 2 1 Zone Local Arming by means of TM key Inspect the condition of loops assigned with this key by once key to reader touching The reader LED shall indicate loop statuses as shown in Table 12 Within 30 seconds after first touching touch the same TM key to reader once more If all assigned loops was not armed disarmed or its arming was failed they will be armed If at least one loop was armed the disarming process begins If at least one alarm loop is of Entry type then sounder begins to beep Ensure all assigned loops have been armed by visual inspecting of its LED indication see Table 11 If a relay is configured as Confirmation then 1 After arming of loop assigned with this relay indicators flashes once per second 2 After message transmission indicators flashes once pe
31. es ee ese 15 AA Patrol Check Gir Cut sd Ee N ee ed ER BERE ER ed ne DER ke DR ee eg 15 4 5 Power Control de ES Ek ER KS SR Ge de cers EG Ge es de ER n de 16 4 6 Panel Operating Modes iese RARR RARR RARR RR RR Re EE ee 16 4 6 1 peralind Mode asie RS Re os Ge de us eg od nia 16 46 2 y CAE O se ME SG dd 16 46 3 Lock Control Mode cintia 16 4 6 4 Key Programming MOdES ooccccccoocccncccconccoccnnoncconcnnnonocnncnnonononnnnnoos 17 4 7 Remote NOAA es 17 4 7 1 Notification by SMS messageS ccccccccccccccnncnnnnonononononnnnnnnnnnnononononoos 17 4 7 2 Notification by Voice Messages cccccccccccooccccccconncccnnnonananoccnonnnnnnnnnos 19 4 7 3 Notification by Contact ID Messages ooooooooocccccooonnnnonononnnnnnnnnnnnnnns 20 4 7 4 Notification by Phone Calls ooooccccccccncccconocconcnononcconononononenennnnninos 21 4 8 Remote CONOS eric 21 5 DELIVERY SET MARKING AND PACKING ooooncccccoccconccccccncannonnnanonnnnnos 22 5 1 Delivery Sa 22 95 2 EG eo N OT EO EE EE EE EE EE We 22 5 3 Pakinga aaeanoa se ER vd O Ge le ee ie 22 GETTING STARTED ese aaa A ee ee 23 6 1 PACMAN ia 23 6 2 TM Reader Connecting cccccsssecccccsscceccnssnssseessanseseesssansssesssannssseaseaness 23 6 3 Alarm Loops Conneelind EA AE EE RE Ee Ee SE GR RE ek ES 23 UO 4S GENERAL 6 4 Executive Devices Connecting iss RE EE EE EE AR EE EE Ee ee 24 6 5 Patrol Check Circuit Connecting ss AR EE EE Ee ee ee ee 24 6 6
32. f TM key being programmed for 2 3 seconds then they will begin to display the statuses of assigned alarm loops Notes If the TM key presented has already been programmed for this panel then UO 4S acknowledges it by once beep If the panel key memory is full meaning that 16 key with Master Key included have already been programmed then the panel sounder emits long error signal If the TM key has been successfully registered by the panel couple it with alarm loops to be armed and disarmed by this key Close in turns the corresponding loop contacts for short time If corresponding LED is lighting it means that this loop is assigned with the key being programmed In order to confirm programming touch the TM reader by this key once more Repeat programming for another TM key if necessary or exit TM Key programming mode by closing reader contacts for 4 seconds or by waiting 30 seconds after any programming operation or by shutting panel power off The exit from programming mode will be confirmed by sounder beep Note If any alarm loop is closed the panel cant leave the programming mode 7 4 3 TM Key Hard Deleting In order to delete the code of a TM key with arming and disarming authorities from the panel memory do the following Disarm Intruder and Entry alarm loops and enter TM Key Programming mode as described in previous section Touching the TM reader by TM Master Key press the panel tamper switch for short time and remove the last o
33. f various zone monitoring methods by means of corresponding alarm loop s Loop Type parameter configuring and all possible logic status arming or disarming controls defining 4 2 1 Loop Types Depending on detecting devices included and users functional needs Loop Type parameter should be defined as one of the following values Fire De Incendio Such a loop is armed without delay and never disarmed Only heat fire detectors can be brought in such a loop Entry Entrada Such a loop is armed and disarmed after a time delay having expired that is entry delay and exit delay can be given for this type of alarm loop Intruder De Guardia Such a loop is armed or disarmed instantly without any time delay Alarm Alarmada Such a loop is armed without delay but never disarmed Entry Intruder and Alarm typed loops can comprise any loop unpowered dry contact output devices such as magnetic contacts intruder detectors or even control and indication equipment outputs for example for smoke detector monitoring if necessary Auxiliary Tecnologica Such a loop is used to enable other loops manual local arming control by any included switch opening for arming and closing for disarming If only authorized control is assumed then a crypto device can be used for such switching otherwise a holding key or lock button can be included into alarm loop 4 2 2 Physical Condition Detecting device monitoring results in loop physical
34. fied alarm loops remotely send such a string from your cell phone to UO 4S cell phone number PXXXXXaSS where XXXXX should be replaced by legal password and SS should be replaced by the sequence of numbers of the loops to be armed Example the command P45235a24 means the authorized instruction for UO 4S to arm alarm loops with numbers 2 and 4 the password presented being 45235 After remote arming the corresponding notification will be transmitted to authorized supervisors It looks like ARMED S S USER NN ARMADO S S USARIO NN where S S are the numbers of loops having been remotely armed and the NN is 20 plus the number of descriptor in panel configuration see section 7 1 1 2 of supervisor that has armed the loops 8 6 3 Remote Alarm Loop Disarming In order to disarm the specified alarm loops remotely send such a string from your cell phone to UO 4S cell phone number PXXXXXdSS where XXXXX should be replaced by legal password and SS should be replaced by the sequence of numbers of the loops to be disarmed Example the command P45235d23 means the authorized instruction for UO 4S to disarm alarm loops with numbers 2 and 3 the password presented being 45235 After remote disarming the corresponding notification will be transmitted to authorized supervisors It looks like DISARMED S S USER NN DESARMADO S S USARIO NN where S S are the numbers of loops having been remotely disarmed and the NN is 20 pl
35. has been disarmed Table 12 External LEDs TM Reader and Patrol Check Circuit Indication Event or Condition Indicator Behavior All loops apart from Alarm and Fire ones are disarmed At least one loop apart from Alarm and Fire ones are armed At least one alarm loop has been broken or its arming has failed Entry alarm loop is arming arming delay having not been expired First TM key to reader Switched off Switched on if power supply is within normal range or flashes once per two seconds otherwise Flashes twice per second Flashes twice per a second if loop resistance is out of range or flashes once per two seconds otherwise TM Reader Indicator only after triple flashings displays current conditions of loops assigned touching in Operating mode with this key Disarming Is switching off Arming Is switching on Patrol Check Patrol Check Indicator only flashes two times Switched off TM Reader Indicator only switches on for 0 5 s Note After single TM key to reader touching the external reader displays the conditions of loops assigned with this key for 30 seconds To arm or to disarm the assigned zones touch the same key to reader once more within this 30 second period Key Programming mode Unknown Key 39 BOLD UO 4S GSM 4 ZONE ALARM PANEL Table 13 Internal Sounder Indication Event or Condition Sounder Behavior Operating mode Switched off Breaking of an associated o loop
36. he required type in Tipo de aviso TEST dropdown menu You can choose not being notified or SMS notification every several hours or phone calls every several hours or minutes Select the proper numerical time value in the window Periodo de transmision below Next choose the communication way in order to transmit alarm and service notifications from UO 4S panel to system owner in question in Protocolo de transmisi n de mensajes field lt will be one way from Mensaje SMS Llamada de voz Contact ID ADEMCO and Llamada telef nica Notes Please keep in mind that 1 Selected types of TEST notification must be in agreement with type of other notifications If SMS channel is selected to be transmission way then TEST notification has to be transmitted as SMS too If all event messages are transmitted via any other channel TEST notifications are to be typed as phone call 2 TEST notifications are transmitted ONLY to phone numbers defined in Tel fono 1 OR Tel fono 2 descriptor 3 TEST notifications are NOT transmitted when all alarm loops are disarmed 4 Each TEST notification is transmitted when time period designed in Periodo de transmision field has been expired since any last transmission that is alarm notification or service notification or preceding TEST one If the time pointed is zero then notifications will not be transmitted 5 Remember that GSM signal receiving level should be at least a half of telephone scale if Conta
37. l Testing AlgorithM iese EE EE EE EE EE 46 11MANUEAGTURER DATA des ee BEE ED RE ees eu N ees se eene ees 49 Warranty AA ER EE 50 UO 4S GENERAL This Installers and User s Manual is intended to help for studying of operability principles and maintenance of UO 4S GSM 4 Zone Alarm Panel revision 02 version 2 14 The UO 4S version number is represented on the label on the device bottom or on the device PCB Please read these instructions completely before connecting operating adjusting or maintaining this product BOLID o ara UO 4S GSM 4 ZONE ALARM PANEL 1 GENERAL UO 4S GSM 4 Zone Alarm Panel revision 02 hereinafter referred to as panel is a control and indicating equipment designed to be the basic element of a fire amp burglary system suitable for security providing of various assets such as houses shops offices enterprises and so on The UO 4S panel main functions are 1 User programmable monitoring of up to four different zones in order to detect fires intrusions breaking and opening or closing of doors windows safes and so on 2 Internal and external sound and light alarm in case of connected detectors having actuated 3 Two executive device automated control in accordance with one of the five available programs external indication confirmation sending lock control and remote control 4 Remote alarm and service notification and remote relay control by up to five authorized supervisors through GSM
38. lay K2 ZZZZ are the numbers of alarm loops assigned with external siren SSSS are the numbers of alarm loops designed to be armed by auxiliary loop opening DDDD are the numbers of alarm loops designed to be disarmed by auxiliary loop closing BBBB are the numbers of alarm loops assigned with the internal panel sounder The separating characters 0 8 9 7 6 are mandatory 7 2 5 Autoarming Adjusting In order to point alarm loops to be automatically armed since several time interval after breaking add the following entry to the contact list Name Phone Number AutoXXXX YYY 34 UO 4S UO 4S CONFIGURING where XXXX is the list of alarm loop numbers to be autoarmed after breaking YYY is the time period ranged from O to 255 seconds for arming to be delayed after breaking 7 2 6 Siren Operating Time Adjusting In order to give external siren operating time while associated loops are broken add the following entry to the contact list Name Phone Number Sir YYY where YYY is the number of seconds you want the connected siren to be switched on in case of assigned loop breaking The time value can range from O to 255 seconds with O meaning not sounding and 255 meaning the siren will sound continually until alarm will be reset By default the siren operating time is set to zero not sounding 7 2 7 Inner Sounder Operating Time Adjusting In order to give panel internal sounder operating time while associate
39. lay being strictly designed to connect a siren The maximum relay direct switching current is 1A while the maximum alternating one is 0 5 A The maximum relay switching voltage is 24 V for direct current and 100 V for alternating current The maximum relay switching power doesn t exceed 10 W 2 3 Touch Memory Reader Input UO 4S panel is equipped with input contacts to connect an identifier reader circuit No more than four Touch Memory contact devices can be brought in parallel across identifier reader circuit contacts There is only one contact terminal to connect external reader LED The overall length of reader connecting wires must not exceed 100 m provided wire diameter is no less than 0 5 mm The UO 4S storage memory capacity is 16 TM identifiers BOLD UO 4S GSM 4 ZONE ALARM PANEL 3 UO 4S DESIGN UO 4S GSM 4 Zone Alarm Panel is implemented in plastic case whose view along with overall and mounting dimensions are demonstrated in Figure 3 1 F N 35 Figure 3 1 UO 4S Overall and Mounting Dimensions 3 1 Panel Light Indicators There are six LED indicators on the panel top cover the upper LED indicating GSM connection status next READY LED indicating the panel itself conditions and rest four LEDs indicating statuses of four connected alarm loops respectively 3 2 Panel PCB and Terminal Blocks Within panel case the device PCB is housed with boa
40. mage certificate describing the defect and acceptance certificate below to validate the warranty status UO 4S GSM 4 Zone Alarm Panel Product Designation Serial Number Produced tested by quality control department in compliance with state standards and specifications and packed by NVP BOLID Company Q C STAMP Name Date 50
41. ming sesse ss see ees ss ss ee ee sk ee ee ee ee ee 36 TAS TM Key Hard Deleting ss VEE a AAA 37 8 OPERATING iS ie in Ee Ee Gee Ge Rees 38 8 1 Panel Indi alOn RE ld 38 8 2 Local Arming and Disarming iese EE EE EE EE EE AR EER Ee Rea 41 8 2 1 Zone Local Arming by means of TM keY ie ee ee 41 8 2 2 Zone Local Disarming by means of TM keY iii ee ee 41 8 3 Electromagnetic Lock Control EE ER AR EE RE EE ee 42 8 4 Voice NOUHICAUION vesicssicsscscccsnesetecisencecetonssersisenienecentessedunsdersibensbecsianr aenies 42 8 5 Phone Call NotificatiOn ss EE EE EE ER AA RR EER EE Ee ee ee ee 42 8 6 Remote UO 4S Panel Control sesse EE EE EER EE EE EE EE EE EE EE EER EE EE EE EE ee ee 42 8 6 1 Request for current loop logic statuSeS ss 42 8 6 2 Remote Alarm Loop Arming occcccccconccnncccconnnnnconnononnononanonononaninnnns 43 8 6 3 Remote Alarm Loop Disarming cccccoocnccnnconccconcnnoonconncononononnnonanoos 43 8 6 4 Remote Relay Control iss EE ee RE EE EG e 43 8 6 4 1 TO Switch the Relay On EE DE DE DE DE DE DE 44 8 6 4 2 To Switch the Relay ON ee ee 44 8 6 5 Confirmation Sending cccccconcccoooccononnnoononnoccnonanonannnnnnnnonconanannnos 44 8 6 6 Remote UO 4S Time SettiNg ococccnnnccccconoooooonnnnccnnnoncconononons 44 9 TROUBLESHOOTING siese KEUSES ene SV Ek GESE NEED ERA GERUK Ee ER EE ees ie 45 id MAINTENANCE EE EE OE K Eidi 46 10 1 UO 4S Technica
42. n 7 3 18 UO 4S TECHNICAL DESCRIPTION 5 Each SMS message is preceded by panel name as it was typed while being configured see section 7 1 1 1 6 If there are some notification collected in the panel nonvolatile memory they are transmitted by group all together Up to 16 SMS notifications can be storied in panel memory 4 7 2 Notification by Voice Messages Following is the list of synthesized voice messages that can be transmitted by UO 4S panel to an authorized cell phone All voice messages listed below begin with Atencion es el mensaje del dispositivo n mero NNNN where NNNN is four digital number of UO 4S in question entered upon configuring see 7 1 1 1 section A voice message is considered to have been delivered if it was listened entirely including the number of repetitions given in panel configuration If the message was not fully listened the panel will attempt to connect with the cell phone to send message for given time of transmission attempts see 7 1 1 2 section of this manual Table 2 Synthesized Voice Messages Transmitted by UO 4S Voice Message Received Notification Esta desarmada la zona numero lt N de la zona gt por el usuario lt N de usuario gt The zone alarm loop with specified number has been disarmed by user with specified number Est armada la zona n mero lt N de la zona gt por el usuario NP de usuario gt The zone alarm loop with specified number has been
43. ne Press tamper switch such many times as a number of TM Key to be deleted The LEDs from 1 to 4 will indicate the binary form of TM Key number Press and hold tamper switch for 5 8 seconds When the key has been deleted the panel will sound Then delete other key or exit programming mode by TM Master Key to reader touching or by reader contacts coupling for 3 seconds or by waiting 30 seconds since the last programming operation Note If an attempt of TM Master Key deleting is implemented the panel records parameters into SIM card and DOES NOT DELETE key with zero number that is Master Key 37 UO 4S GSM 4 ZONE ALARM PANEL 8 OPERATING In this chapter it is shown how to monitor your system statuses and events depending on light and sound indication observed how to arm and disarm your system how to receive notifications and how to implement system remote control You can change system settings if necessary as shown in chapter 7 or to add delete TM keys as described in section 7 4 8 1 Panel Indication The Tables below demonstrate the behavior of panel light and sound indicators depending on conditions or events having occurred Table 9 GSM LED Indication 232 line communication Lit by green or yellow 232 line communication has Switched off or flashes by red The level of GSM signal received is too low or communication has been lost Too much GSM errors Flashes by red or yellow four times per a second Table 10
44. nput for reader connection The distance between the panel and the reader cannot exceed 100 m provided the wire cross section area is not less than 0 1 square mm The codes memory capacity is 16 including Master Key identifier UO 4S alarm loops either by one or by a group can be armed and disarmed by means of TM key to reader touching The corresponding authorities are established during key programming as discussed in chapter 7 The specific procedures are described in section 8 2 4 3 Relay Outputs UO 4S panel is equipped with three relay outputs with relay K3 being designed as siren and two other ones being user programmable in according with five available programs described below The relay outputs in question are low powered see specification in 2 2 section so it can be required to include devices with higher commuting parameters in relay circuit 4 3 1 Siren Relay Relay output 3 K3 is designed to connect a siren This relay is to be switched on for a given time when an assigned alarm loop has been broken The operating period and loop coupling are specified during UO 4S configuring The period can be given so as the siren will not be switched off until assigned alarm loop is disarmed 4 3 2 Lock Control Relay Program Lock Control program allows assigning a relay only with one panel alarm loop When the assigned alarm loop has been disarmed or short failed in disarmed condition the relay is switched
45. o the ID de instalaci n field It can contain from one to seven digits or letters and must not begin with 0 If Contact ID protocol or Vice messages are assumed to be used for notifications transmitting through GSM channel the panel identifier must be presented by four nonzero digits Next type the five digital password for remote UO 4S control ability into the Contraseca field If necessary select entry and exit delays from 1 to 255 seconds in Tiempo para entrar and Tiempo para solir fields By default these values are set to 0 that means no delaying Then define each alarm loop settings For each loop select the suitable loop types see 4 2 1 clause from Tipo de Z1 Tipo de Z4 dropdown menus Set Autoarmar switches on if necessary see 4 2 4 section Select the autoarming delay if necessary in Retraso al almar field keeping in mind that autoarming delay for Entry alarm loop should exceed both entry and exit delays set above The value can range from 0 to 255 seconds Enter the text names consisting from 1 to 8 symbols for each loop into Nombres de la zonas fields These names will identify the corresponding alarm loops in SMS messages transmitted by panel while notification If some of the panel alarm loops are configured as auxiliary see 4 2 1 clause mark the alarm loops which must be armed and disarmed after auxiliary loop opening and closing respectively in Armar and Desarmar windows of Tecnol gica 26 UO 4S UO 4S CONFIG
46. onal account balance Liquidate a debt 45 BOL D SESON ETIT UO 4S GSM 4 ZONE ALARM PANEL 10 MAINTENANCE Be sure your UO 4S panel is fully operational by annually inspecting and testing it as described below Do always take care of safety precautions discussed in section 6 1 Study closely panel operating principles and rules presented in this manual before testing In order to discover any defect and estimate panel technical condition do the following 1 Make the visual inspection of the panel Ensure it has no mechanical damages Remove any dirt or dust if presented 2 Inspect the conditions of electric wires connection contacts and panel attachment security 3 Test the panel operability in according with technical algorithm from section 10 1 The inspection and testing have to be carried out at ambient conditions as follows Ambient temperature from 15 to 35 C Relative humidity from 45 to 80 non condensing Atmospheric pressure from 84 to 106 7 kPa 10 1 UO 4S Technical Testing Algorithm WARNING SHUT OFF UO 4S power supply before wires connecting or disconnecting In order to test the panel establish the test set up as shown in Figure 10 1 The overall testing time doesn t exceed 20 minutes Test UO 4S by doing the following 1 Connect 8 2 kQ resistors to the alarm loops 2 Connect power supply to UO 4S and measure input current rating by means of AV amperevoltmeter Ensure the m
47. optimal ratio between delivery reliability and communication expenses If messages to be transmitted are of great importance for the system owner and must not be lost it is advisable to increase the values of parameters in questions If Voice messages are selected to be transmitted set the number of transmission attempts in Numero maximo de mensajes en transmission por canal de voz field By default this value is set to zero so Voice messages cannot be transmitted Voice messages are not repeated in one communication session by default so set the required number of repetitions in Repeticiones de mensajes de voz field if necessary The field Tiempo de escuche maximo en minutos is reserved It can be no more than five GSM supervisors for each UO 4S panel The GSM supervisor is considered to be a panel owner with particular cell phone number communicated with panel only by a single way i e by SMS messages or by Voice messages or by Contact ID protocol or by Phone Call If a phone owner wishes to receive information from panel by several 27 BOL D UO 4S GSM 4 ZONE ALARM PANEL ways he has to be registered in panel configuration several times with the same phone numbers and different notification methods Define each supervisor descriptor in Tel fono 1 Tel fono 5 sections Enter the full cell phone number with international code included in Numero de tel fono field Then describe the parameters of TEST notifications Select t
48. or associated loop fire Sounds in interrupted mode trouble Arming of an associated loop Two short beeps Disarming of an associated If the sounder was on it is switched off or emits loop a beep otherwise Short beeps once per two seconds Within 15 sec before arming delay having been expired the beep frequency increase up to twice pera second Delaying of arming Illegal TM key to reader touching Arming of a loop has failed Sounder is off TM Key Programming mode entering Long sound Three short double sounds If the key code has already been recorded into UO 4S memory then the sounder emits a beep If the TM key been touched is unknown the sounder acknowledges the new key code recording into the UO 4S memory by two TM key to reader touching in beeps Key Programming mode If UO 4S key memory is full and all 16 key codes have already been recorded then the sounder emits long sound signal It is necessary to delete an existing key in order to program new key Master Key Programming mode entering TM key to reader touching in Master Key Programming Two beeps mode TM key deleting One long and two short sounds Two short twice beeps and then one long sound 40 UO 4S OPERATING 8 2 Local Arming and Disarming Local zone arming and disarming are implemented by three different ways as was discussed in section 4 2 namely by autoarming after breaking by auxiliary alarm loop assigned with this zone op
49. r second 3 After confirmation receiving the indicator is lit steady 8 2 2 Zone Local Disarming by means of TM key Inspect the condition of loops assigned with this key by once key to reader touching The reader LED shall indicate loop statuses as shown in Table 12 Within 30 seconds after first touching touch the same TM key to reader once more in order to disarm assigned loops if at least one was armed or broken If all assigned loops was not armed disarmed or in arming failed status then the second touching will lead to all assigned loops arming 41 BOLID SESON TITER UO 4S GSM 4 ZONE ALARM PANEL If loop of Entry type is broken it enters actuated status If not disarmed within 30 seconds then an alarm is initiated 8 3 Electromagnetic Lock Control Electromagnetic Lock Control is enabled if only the corresponding relay is configured with Lock Control type Such a relay is switches on releasing a door for 4 seconds when the associated alarm loop either has been disarmed or has been closed after being disarmed 8 4 Voice Notification If synthesized voice notifications are transmitted to you authorized cell phone listen a message received fully If the phone call is discarded before the voice message is played completely then UO 4S will repeat the attempts to transmit the message if the number of attempts are set in a value more than 1 see section 7 1 1 2 8 5 Phone Call Notification If phone call notification
50. ra and so on provided they are connected through more powerful commuting devices 4 3 6 Switch Off After Loop Disarming Relay Program This type of relay program is also designed for external indicating Such a relay can be assigned only with single alarm loop The relay is switched on when assigned alarm loop is armed When the alarm loop has been disarmed the relay is switched off 4 4 Patrol Check Circuit If UO 4S alarm panel is used for centralized safeguard the Control Check facility can be used in order to implement scheduled inspection of assets being protecting A Patrol Check circuit with sealed contact shunted by 1 KQ resistor and external LED indicator in series included is connected to the corresponding panel contact terminals see section 6 5 When a patrol has inspected an asset being protected the magnet is touched to sealed contact with corresponding signal being transmitted to the Central Guard Station This signal can designate the inspection having been successful or can be used to verify the inspection implementation 15 BOL D UO 4S GSM 4 ZONE ALARM PANEL 4 5 Power Control If the UO 4S panel is powered by RIP 12 uninterrupted power supply manufactured by Bolid Company it can monitor the AC line functionality and indicate failing or recovering of mains power line locally and remotely To enable this option connect Knut and O B panel PCB contact terminals see Figure 3 2 to OC and 0
51. rd layout being showed in Figure 3 2 The main components shown are the GSM module with the built in internal antenna and SIM card reader the internal sounder the port for UO 4S to PC connecting the tamper switch for unauthorized tampering detecting and the group of screw clamp terminals for input and output circuit connecting as follows UO 4S UO 4S DESIGN To PC COM port for configuring SIM Card To External Antenna Internal Antenna OREADY we Tamper Switch The Jumper should be set on while PC configuring and operating External Touch Memory Reader Y To Siren EER To executive Devices m gt The example le 10 kOhm of fire heat ET detector connection Intruder Loop Auxiliary Loop 8 2 kOhm Intruder Loop gt gt To Patrol Check Circuit To OC RIP Output To 12V Power Supply Figure 3 2 UO 4S Panel PCB Layout SECURITY SYSTEMS UO 4S GSM 4 ZONE ALARM PANEL COB Assignment Designator 9 LED 25 0B 24 To connecta TM reader circuit as shown in Figure 3 2 TM 23 Ka oe To connect a siren K3 21 K2 20 T K2 19 o connect an executive device 2 K1 18 s K1 47 To connect an executive device 1 LLC4 1 ie i Negative and positive contacts to connect an alarm loop 4 LLIC3 14 ed 13 Negative and positive contacts to connect an alarm loop 3 LUC2 12 N Ad LUC2 4
52. red operation and specified alarm loop Type a text name for TM key if necessary You cannot assign any authority to the Master Key because it is designed to switch the panel into programming mode When the list of TM keys has been created you can change key authorities as described above or delete any key by means of Borrar llave tool button You can write all programmed keys into a file of special format to a floppy disk by means of Guardar el fichero de los cydigos de llaves tool Such a disk can be used to load all programmed keys into any other UO 4S panel to be controlled by the same TM keys In order to store key adjustment into panel non volatile memory select Guarda las llaves en dispositivo tool button 7 2 UO 4S Configuring by Means of a Cellular Phone Configuring the panel via its SIM card makes not so much opportunities as programming by means of a PC The message filters can not be adjusted by means of a cell phone all available messages being transmitted to all registered supervisors The TM key codes are not programmable through a SIM card In such a case they are to be registered by hardware as shown in section 7 4 Moreover there is no any feedback when configuring by means of cell phone settings A mistake within entered command can cause a malfunction of panel operability So be careful when programming the UO 4S SIM card manually 30 UO 4S UO 4S CONFIGURING In order to program UO 4S panel through SIM card
53. s are transmitted to you authorized cell phone then accept call receiving and UO 4S will discard this call within 2 seconds If you discard or ignore such a call then UO 4S will repeat the attempts to transmit the message until the configured number of attempts has expired see section 7 1 1 2 8 6 Remote UO 4S Panel Control UO 4S remote control is implemented by means of sending SMS containing a password protected command from authorized cell phone to UO 4S phone number A command can be fulfilled if only source phone number and the password presented are programmed in UO 4S configuration The owner of such a phone can request the current status of alarm loops that is are the alarm loops armed or disarmed send arming or disarming command send executive relay command send arming report confirmation or change current time All available commands along with corresponding strings of symbols being entered from phone keypad are presented below 8 6 1 Request for current loop logic statuses In order to request current alarm loop logic statuses and to inspect are they armed or disarmed now send such a string from your cell phone 42 UO 4S OPERATING PXXXXXQ where XXXXX should be replaced by legal password If there are no loops armed the reply will be DISARMED DESARMADO otherwise the reply will be ARMED S S ARMADO where S S is the numbers of armed loops 8 6 2 Remote Alarm Loop Arming In order to arm the speci
54. sarmed and Arming Failed The panel switches an alarm loop between Armed and Disarmed statuses by four possible configurable ways By autoarming with programmable time delay see clause 4 2 4 By auxiliary loop closing or opening see clause 4 2 1 Local control by means of TM key to reader touching see clause 4 2 5 Password protected remote SMS control see section 8 2 f physical condition of a loop is Norm during arming that is its resistance is within normal range this loop enters Armed logic status Otherwise this one enters Arming Failed status Loop disarming always results in Disarmed status entering Entry alarm loop enters Armed status after given time that is exit delay since TM key to reader touching if its resistance is within normal range 4 2 4 Loop Autoarming All alarm loops except Fire one can be automatically armed since specified time interval after breaking and recovering if this loop has not been disarmed all this time For Entry loop the autoarming interval must exceed exit and entry delays 4 2 5 Local Arming and Disarming by TM Keys The panel provides the connection of the reader of electronic identifiers formatted as Dallas Touch Memory The user identification is performed by key code reading 13 BOLID EE UO 4S GSM 4 ZONE ALARM PANEL The reading and writing of a code is realized by means of touching the reader with the electronic identifier The panel is supplied by single i
55. sary to open the panel top cover After programming completing put the panel cover on 7 4 1 TM Master Key Hard Programming In order to program TM Master Key by hardware power the UO 4S panel off and couple TM reader contact terminals Then switch on the panel again Panel to TM Master Key Programming mode entering shall be confirmed by two double short and one long signal of panel internal sounder Disconnect TM reader contacts and touch the reader by a TM key within 10 seconds after disconnecting Two short beeps will confirm the new Master Key recording into the panel memory all information about TM keys programmed before being erased To exit the TM Master Key Programming mode do one of the following couple TM reader contacts for 4 seconds or wait for 30 seconds or shut off the panel power 7 4 2 TM Key Hard Programming In order to program TM keys suitable for zone arming disarming the maximum number of such the keys is 15 ensure all Intruder and Entry alarms are disarmed Otherwise the TM Key Programming mode is unavailable Switch the panel power on and wait for 10 seconds Touch the Master key to the TM reader The panel internal sounder will emit three double beeps confirming TM Key programming mode entering Touch the TM reader by TM key to be programmed Its code will be recorded into the panel memory the sounder emitting two beeps The 36 UO 4S UO 4S CONFIGURING LEDs from 1 to 4 will indicate the number o
56. upervisor as described in chapter 7 The supervisor enrolls the panel phone number with a text comment as a name into his or her cell phone contact list When the event programmed has happened the UO 4S panel shall call supervisor phone with the event description being displayed on the cell phone screen The user receives the call the panel discarding the communication immediately resulting in the call to be no paid for 4 8 Remote Control UO 4S remote control is implemented by means of sending SMS message containing a password protected command to UO 4S destination phone number The command can be fulfilled if only source phone number and the password presented are programmed in UO 4S configuration see 7 1 1 1 section The list of remote control operations available for such a phone owner is as follows see 8 6 section for more details Request for current logic statuses of alarm loops armed or disarmed Specified alarm loop arming Specifies alarm loop disarming Specified relay switching for given time period Report Confirmation sending Time setting 21 BOL D a UO 4S GSM 4 ZONE ALARM PANEL 5 DELIVERY SET MARKING AND PACKING 5 1 Delivery Set Following is the list of the UO 4S GSM 4 Zone Alarm Panel components being delivered from manufacturer Y UO 4S GSM 4 Zone Alarm Panel This Installers and User s Manual 3 self tapping screws 3x25 016 with 6x30 dowels 4 loop termination resistors MF 1
57. us the number of descriptor in panel configuration see section 7 1 1 2 of supervisor that has disarmed the loops 8 6 4 Remote Relay Control Remote Relay Control is enabled only if the corresponding relay is configured with External Control type 43 BOLID TEOT UO 4S GSM 4 ZONE ALARM PANEL 8 6 4 1 To Switch the Relay On In order to switch the relay on send a PXXXXXrNYtZ SMS message from your cell phone to UO 4S phone number where XXXXX is your remote control password N is the relay number 1 or 2 Y is one for relay switching on and zero for relay switching off Z is the relay operating period in seconds the maximum value being 255 If Z is missed or equal to zero then the operating period is unlimited and the relay will be switched on until switching off command having been received Example the SMS message P12345r21t4 will be considered as the command to switch the second relay on for 4 seconds 8 6 4 2 To Switch the Relay Off In order to switch the relay off send a PXXXXXrN0 SMS message from your cell phone to UO 4S phone number where XXXXX is your remote control password N is the relay number 1 or 2 Example the SMS message P12345r10 will be considered as the command to switch the first relay off 8 6 5 Confirmation Sending In order to send a confirmation of arming report receiving send such a string from your cell phone to UO 4S phone number PXXXXXk where XXXXX should be replaced by legal pass
58. word 8 6 6 Remote UO 4S Time Setting Send UO 4S a PXXXXXtHHMM SMS message where XXXXX is your remote control password and HHMM is the required time value from your cell phone Example the command P45235t1200 means the authorized instruction for UO 4S to set current time in 12 hours 00 minutes the password presented being 45235 44 UO 4S TROUBLESHOOTING 9 TROUBLESHOOTING Use the Table 14 to resolve some problems during UO 4S operating Table 14 Problem resolving Problem Possible Cause Solution READY indicator isn t lit TT He Check the UO 4S power after UO 4S powering up y 9 supply connection GSM indicator flashes by red or yellow eight times per a second SIM card is not installed within UO 4S PIN Code Prompt is enabled Make sure a SIM card is inserted within UO 4S GSM module Disable PIN Code Prompt by means of a cell phone Communication with cell phone operator is lost or level of signal received is below the normal value Check the antenna or attach an external antenna to UO 4S Ensure signal level at UO 4S location is within normal range by means of a cell phone SMS messages fails to transmit with READY indicator flashing GSM communication lost Check the antenna or attach an external antenna to UO 4S Incorrect SMS centre phone number Enter the correct phone number of SMS centre in accordance with cell phone instructions Deficit of pers