1. EUROTHERM EUROTHERM Setting the standard Eurotherm a company that understands signal conditioning and isolating For over 35 years Eurotherm has built an international reputation for developing premium quality fit for purpose products and solutions The Eurotherm brands Action Instruments Barber Colman Chessell Continental and Eurotherm have long been recognized as the leaders in the industrial automation market Action Instruments provides the signal conditioning industry the highest quality most innovative solutions to remote signal conditioning and isolation applications Action defined the standard for accuracy and reliability and our focus on technological innovation continues to raise that standard The people behind the Action Instruments brand are devoted to understanding your needs and overcoming obstacles to the collection and transmission of industrial automation process signals Easy Solutions to Tough Problems Every Action product is designed for easy installation operation and maintenance Whether you are amplifying or splitting signals conditioning sensor outputs isolating grounding problems or adding more drive to current loops Action s complete product selection provides simple convenient solutions to any analog signal conditioning need High Performance and Proven Reliability Reliable signal processing under harsh conditions That s what Action s products deliver Nearly three
2. Field Configurable Input for Thermocouple RTD mV amp mA 3 Field Configurable Alarm Setpoints with 1 or 2 Alarm Outputs Bright Green 4 Digit 9999 LED Display Programmable for Engineering Units Combination Alarm Functions Alarm Blocking amp Programmable Latching Non Latching IP65 Front Panel with Tactile Configuration Buttons Standard Power Supply 85 to 264VAC 48 to 62Hz or Optional 20 to 29VDC VAC n a on V108 Specify V108 ALGNVH V108 ALRDVH V116 ALVH V116 ALVL V132 ALVH V132 ALVL Accessories SUB2 1V1 SUB2 1R7 1 8 DIN Green LED Display 85 264 VAC PS 1 8 DIN Red LED Display 85 264 VAC PS 1 16 DIN Green LED Display 85 264 VAC PS 1 16 DIN Green LED Display 20 29VDC VAC PS 1 32 DIN Green LED Display 85 264 VAC PS 1 32 DIN Green LED Display 20 29VDC VAC PS 0 to 10V Input Adapter External Relay V116 and V132 only All units ship with mounting brackets a 2 49 ohm shunt resistor and a user manual WWW eurotherm Universal Field Configurable Input for Thermocouple RTD mV amp mA Bridge and 0 to 10V Signals e Modular Design Provides 3 Option Slots plus 1 Optional Modbus Communications Slot e Option Modules for 2nd Input DC Retran Sensor Excitation 3 Digital Inputs Outputs and Relays e 4 Field Configurable Setpoints Support Combination Alarm Functions Rate of Change Deviation Alarms Alarm Blocking and Latching Non Latching IP65 Front Panel with Plug I
3. 86 0411 265498 Fax 86 0411 2650498 E mail sales actionio com cn Soliton Brazil Telephone 5511 6950 1834 Fax 5511 6979 8980 E mail soliton soliton com br Eurotherm is also represented in the following countries Azerbaijan New Zealand Bahrain Nigeria Bangladesh Oman Bulgaria Pakistan Canada Phillipines Czech Republic Poland Egypt Quatar Georgia Romania Greece Russia Hungary Saudi Arabia Indonesia Singapore Iran Slovak Republic Iraq Slovenia Israel South Africa Japan Sri Lanka Jordan Thailand Kazakhstan Turkey Kenya Turkmenistan Kuwait United Arab Emirates Latvia Ukraine Lithuania Uzbekistan Malaysia Copyright 2005 2006 Eurotherm Inc Invensys Eurotherm and the Eurotherm logo are trademarks of Invensys plc its subsidiaries and affiliates All other brands are trademarks of their respective owners All rights are strictly reserved No part of this document may be reproduced modified or transmitted in any form by any means nor may it be stored in a retrieval system other than for the purpose to act as an aid in operating the equipment to which this document relates without the prior written permission of Eurotherm Inc Every effort has been taken to ensure the accuracy of this specification However in order to maintain our technological lead we are continuously improving our products which could without notice result in amend ments or omissions to these specifications We cannot accept
4. C Limit Alarm Alarm Dual SPDT Relay 50 adjustment in any range Type B 500 to 1820 C Isolator Type E 150 to 1000 C Thermocouple Type J 200 to 750 C Type K 200 to 1370 C ud Type R S 50 to 1760 C Limit Alarm Type T 150 to 400 C Alarm Dual SPDT Relay DC Voltage 0 5V 0 10V Isolator Potentiometer 100 ohms to 100k ohms DC Current 0 1MA 0 20mA 4 20mA 0 to 200mV G448 Isolator Strain Gauge 5mV to 200mV ze as ie Coe ETES Excitation 1 10VDC 120 mA i 50mV AC to 250VAC DC Voltage 0 5V 0 10V case AC Volts 50mA AC to 100mA AC DC Current 0 1mA 0 20mA 4 20mA AC Current T 50mV AC to 250VAC G168 Limit Alarm 50mA AC to 100mA AC Alarm Dual SPDT Relay DC Voltage 0 5V 0 10V WV905 Power Supply 100 to 240VAC 50 to 60Hz 24VDC 500mA DC Voltage 0 5V 0 10V DC Current 0 1mA 0 20mA 4 20mA Www eurotherm com actionio Actionl Q DIN Rail Mount Signal Conditioners Isolators and Alarms e Multi channel Conditioners e Interlocking Modules e Two Wire Transmitters e Optional I Q Rail Power Bus e SnapLoc Terminal Blocks e PC Based Setup e Removable Connectors e Math Modules The Actionl Q Series of signal conditioners have wide ranging field configurable inputs and outputs These DC RTD T C potentiometer bridge strain gauge AC and frequency input devices incorporate TouchCal technology which simplifies calibration and allows more than 90 adjustment of zero and span Isolation 18
5. 2 SPDT Relay 5A 0 to 200mV AP4081 Signal Conditioner Strain Gauge 5mV to 200mV ee as Excitation 1 10VDC 120mA i n AC Volts 50mV to 200V DC Voltage 0 5V 0 10V AAEN Sietial Comaitioner AC Current 5mA to 100mA DC Current 0 1mA 4 20mA Pt100 0 00385 0 003911 0 003912 200 to 870 C Pt200 0 00385 0 003911 0 003912 200 to 870 C Pt500 0 00385 0 003911 0 003912 200 to 870 C DC Voltage 0 5V 0 10V AP4151 Signal Conditioner 2 amp 3 Wire RTD DC Current 0 20mA 4 20mA Ni100 0 00618 100 to 320 C Ni120 0 00672 100 to 320 C Cu9 035 0 00427 200 to 260 C to 20kHz 50mVpp min Frequency to 40kHz 1Vpp min to 80kHz 5Vpp min 24VDC 5 40 VDC unregulated AP9046 Power Supply 120VAC 50 to 400Hz 65mA max 24VDC 5VDC pulse 10mA max TTL compatible or 24VDC pulse 1kQ min load frequency to 0 99999 of max input AP7510 Frequency Divider Scaler WwWw eurotherm com actionio IP51 and IP61 Current to Pressure Transducers e NEMA 4X or Explosion Proof e Accuracy Greater Than 0 15 e Intrinsically Safe e Calibrate Without Removing Tubes or Wires e Field Configurable Direct Split and Inverse Ranges IP51 and IP61 current to pressure converters produce a pneumatic output in response to a current input They are useful for applications involving the control of actuators and valves or for interfacing electrical equipment to pneumatic instrumentation Thei
6. 4 20mA out V430 3000 1 DC VI Rate Total 120VAC 2 Relays 4 20mA Out V432 0000 1 T C RTD 120VAC V432 1000 1 T C RTD 120VAC 2 Relays V432 2000 1 T C RTD 120VAC 4 20mA Out V432 3000 1 T C RTD 120VAC 2 Relays 4 20mA Out V432 0000 D T C RTD 24VDC V432 1000 D T C RTD 24VDC 2 Relays V432 2000 D T C RTD 24VDC 4 20mA Out V432 3000 D T C RTD 24VDC 2 Relays 4 20mA Out V434 0000 1 Bridge Strain 120VAC V434 1000 1 Bridge Strain 120VAC 2 Relays V434 2000 1 Bridge Strain 120VAC 4 20mA Out V434 3000 1 Bridge Strain 120VAC 2 Relays 4 20mA Out V437 0000 1 DC VI Rate Total 120VAC V437 1000 1 DC VI Rate Total 120VAC 2 Relays V437 2000 1 DC VI Rate Total 120VAC 4 20mA out V437 3000 1 DC VI Rate Total 120VAC 2 Relays 4 20mA Out V438 0000 1 DC VI W lineariz 120VAC V438 1000 1 DC VI W lineariz 120VAC 2 Relays V438 2000 1 DC VI W lineariz 120VAC 4 20mA out V438 3000 1 DC VI W lineariz 120VAC 2 Relays 4 20mA Out V438 0000 D DC VI W lineariz 24VDC V438 1000 D DC VI W lineariz 24VDC 2 Relays V438 2000 D DC VI W lineariz 24VDC 4 20mA out V438 3000 D DC VI W lineariz 24VDC 2 Relays 4 20mA Out com actionio Eurotherm International Sales and Service Providing local support is a key part of Eurotherm s business Complementing worldwide Eurotherm offices are an entire range of partners and a comprehensive support team a soothing melody in tune with your needs AUSTRALIA Sydney
7. DC Current 0 20mA 4 20mA Copper RTD 200 to 260 C 95 adjustment in any range 95 adjustment in any range Limit Alarm 2 amp 3 Wire RTD Alarm Dual SPDT Relay Type B 75 to 1800 C Type C 0 to 2315 C 428 only DC Voltage 0 10V Isolator Type E 200 to 1000 C 12 7mm DC Current 0 20mA 4 20mA Type J 210 to 760 C 95 adjustment in any range Thermocouple Type K 200 to 1370 C Type N 200 to 1300 C 428 only Type R S 0 to 1760 C Limit Alarm Type T 200 to 390 C 17 5mm Alarm Dual SPDT Relay 95 adjustment in any range Part Number WV408 Isolator DC Volts DC Current WV108 Limit Alarm WV418 WV118 WV428 WV128 DC Voltage 0 10V WV438 Isolator Potentiometer 100 ohms to 100k ohms 12 7mm DC Current 0 20mA 4 20mA 95 adjustment in any range DC Voltage 0 10V WV448 Isolator Strain Gauge aul to Samy 17 5mm DC Current 0 20mA 4 20mA Excitation 1 10VDC 120mA D 95 adjustment in any range DC Voltage 0 10V WV468 Isolator TA lt 4 ney m 12 7mm DC Current 0 20mA 4 20mA AC Volts 95 adjustment in any range WV168 Limit Alarm AC Current 50mV AC to 250VAC 20mA AC to 100mA AC Alarm Dual SPDT Relay DC Voltage 0 10V Isolator Frequency 2Hz to 10kHz 12 7mm DC Current 0 20mA 4 20mA 95 adjustment in any range AC Power 85 to 265VAC 50 to 60Hz Communications DC Paner 22 5mm Config summary editing diagnostics alarm setup status e mail
8. Eurotherm Ireland Limited Telephone 353 01 469180 Fax 353 01 4691300 E mail info eurotherm ie ITALY Como Eurotherm S r l Telephone 39 31 975111 Fax 39 31 977512 E mail info eurotherm it KOREA Seoul Eurotherm Korea Limited Telephone 82 31 2738507 Fax 82 31 2738508 E mail help eurotherm co kr NETHERLANDS Alphen a d Ryn Eurotherm B V Telephone 31 172 411752 Fax 31 172 417260 E mail info eurotherm nl NORWAY Oslo Eurotherm A S Telephone 47 67 592170 Fax 47 67 118301 E mail info eurotherm no SPAIN Madrid Eurotherm Espa a SA Telephone 34 91 6616001 Fax 34 91 6619093 E mail ventas iberica eurotherm co uk SWEDEN Malmo Eurotherm AB Telephone 46 40 384500 Fax 46 40 384545 E mail info eurotherm se SWITZERLAND Freienbach Eurotherm Produkte Schweiz AG Telephone 41 55 4154400 Fax 41 55 4154415 E mail epsag eurotherm ch UNITED KINGDOM Worthing Eurotherm Limited Telephone 44 1903 268500 Fax 44 1903 265982 E mail info eurotherm co uk Web www eurotherm co uk UNITED STATES Leesburg VA Eurotherm Inc Telephone 1 703 443 0000 Fax 1 703 669 1300 E mail info eurotherm com Web www eurotherm com Represented by Specialist Partners Tempcon Instrumentation Ltd Telephone 0870 774 6222 Fax 0870 774 6555 Email info tempcon co uk International Telephone 44 0 1243 558277 International Fax 44 0 1243 558288 Dalian China Telephone
9. Frequency 2 5mA 25mA DC Current 0 20mA Q498 Isolator Discrete to 18V 2Hz to 10kHz 150mVp to 150Vrms Frequency 0 to 10kHz Discrete to 18V Math Functions Add Subtract Multiply Divide Square Root Q425 0B01 l a Q425 0B03 Transmitter Thermocouple Lids J r 7 aa DC Voltage 0 10V both 3 Wire eye The Q498 is a DC powered DIN rail mount DC input signal conditioner The unit is fully isolated to 1800V between input output and power Two isolated analog inputs each accept either a DC voltage or current One analog output delivers either DC bipolar voltage or unipolar current The Q498 also has a separate frequency input channel and a frequency output as well as a discrete input and output channel The Q498 can perform single or double input math calculations on the input values The available operators are Addition Subtraction Multiplication Division Square Root and Average Process control functions include Hi Lo Select Rate of Change Limiter and Track amp Hold The frequency input can also have the math functions applied A 25 point linearization function is available for Channel 1 Analog input only All output math and process control functions require C698 0000 software WwWww eurotherm com actionio Action Pak Plug In Signal Conditioners Isolators Alarms and Power Supplies SPECIFICATIONS Isolation Limit Alarms 1000VDC between input output and power Signal Conditioners 1500VDC between input output a
10. Interface process variable viewing data logging www eurotherm com actionio WV478 WVvV905 WVC16 oo eT Ultra SlimPak DIN Rail Mount Signal Conditioners Isolators and Alarms e Field Configurable e High Density DIN Rail Mount e Wide Ranging e ASIC Based Design for Maximum Reliability Ultra SlimPaks are high density DIN Rail mount setpoint limit alarm and isolating signal conditioner modules All Ultra SlimPak modules utilize Action s advanced ASIC based design for field configurable input and output flexibility Isolation 1800VDC between input output and power except G438 al Operating Humidity 15 to 95 45 C e Temperature Range sol Operating 0 to 55 C 25 Storage 25 to 70 C Power Consumption 1 5W typical 2 5W max Supply Range 9 to 30VDC except G448 is 18 to 30VDC Agency Approvals UL CSA CE Partnumber function input Input Span Field Configurable ae Output Field Configurable G408 DC Voltage 0 5V 0 10V iolat r DC Volts 10mV to 100V 126mm DC Current 0 1mA 0 20mA 4 20mA DC Current 1mA to 100mA G408 1001 DC Voltage 5 to 5V 10 to 10V noe 10mV to 200V G108 Limit Alarm en 1mA to 100mA Alarm Dual SPDT Relay Platinum 100 500 1000 Ohm with 16 ranges from 200 to 600 C down to 18 to 50 C DC Voltage 0 5V 0 10V Isolator DC Current 0 1mA 0 20mA 4 20mA 3 Wire RTD Copper 10 25 100 Ohm with 9 ranges from 200 to 260 C down to 18 to 50
11. Loop Power Supply V560 565 3 1 2 digit Remote Loop Powered Indicator with wide ranging display C680 0002 Zero Span Trimmer com actionio TransPak 1797 1798 Isolating Universal 2 Wire Transmitters e Programmable for 11 T C Types 6 RTD Types mV or Ohm Inputs Isolated Linearized Current Loop Output for RTD or Thermocouple Input HART Compatible or Field Configurable with Optional Display Intrinsically Safe Operation or with Display and Explosion Proof Enclosure The T797 is a programmable temperature transmitter that can be factory or field configured using the optional 1 or 2 line alphanumeric display The T798 is a Highway Addressable Remote Transducer HART based temperature transmitter that can be factory or field configured using either the optional 1 or 2 line alphanumeric display or the optional PC based modem and software Alternatively an HC275 Hand Held Communicator loaded with the Action T798 Device Description from the HART Foundation Library can be used Input Types Thermocouple B C E J K L N R S T U and Special RTD Pt 100 2 wire 3 wire 4 wire 385 or 392 mV 15mV to 115mV Resistance 0 to 500 Ohms Linearization Accuracy T C and RTD linearized to 0 05 C 0 05 of the millivolt or ohm equivalent input reading or the value from the accuracy table whichever is greater plus 0 05 of span For thermocouples add 0 5 C 0 9 F for cold junction compensation
12. Output Type J 0 to 500 F 0 to 1000 F 0 to 500 C Q520 0Bxx Loop Powered Thermocouple 2Ch Type K 0 to 500 F 0 to 2000 F 0 to 1000 C 22 3mm 4 to 20mA DC Transmitter Type T 0 to 500 F 0 to 250 C Pe DC Volts 10mV to 200V Q404 2L08 DC Volts 2 Ch 0 to 10V 4 to 20mA DC Q404 2L09 DC Volts 2 Ch 0 to 10V 0 to 10VDC Q404 2L28 kolator DC Volts 2 Ch 10 to 10V 22 3mm 10 to 10VDC Q404 3L00 DC Current 1 Ch 24 VDC Excitation 4 to 20mA 4 to 20mA DC Q404 3L01 DC Current 1 Ch 24 VDC Excitation 4 to 20mA 0 to 10VDC Q404 4L00 DC Current 1 Ch In 2 Ch Out 4 to 20mA 4 to 20mA DC DC Voltage 0 5V 0 10V ES Isolator i e WA 22 3mm DC Current 0 1mA 0 20mA 4 20mA 0 20mA on A000 only DC Voltage 0 5V 0 10V 0 to 200mV Q448 Isolator Strain Gauge 5mV to 200mV 22 3mm ee aa N pee A 4 20MA Excitation 1 10VDC 120 mA AC Volts 100mvV to 300V DC Voltage 0 5V 0 10V DC Voltage 0 5V 0 10V Type B 0 to 1820 C Type C 0 to 2320 C Type E 270 to 1000 C Type J 210 to 760 C Type K 270 to 1372 C Type N 200 to 1300 C Type R 0 to 1760 C isalator Universal Type S 0 to 1750 C DC Voltage 0 10V includes 2 3 amp 4 Wire RTD Type T 270 to 390 C DC Current 0 20mA Pt100 Pt200 Pt500 Pt1000 200 to 850 C Cu 9 035 40 to 260 C Ni120 80 to 320 C 90mV 900mV 0 to 4000 ohms DC VI 2 Ch Isolated 150mV 1 5V 15V 150V DC Voltage 0 10V 10V
13. 00VDC or peak AC between input output and power Operating Humidity 15 to 95 45 C Temperature Range Operating 0 to 55 C Storage 25 to 70 C Power Consumption 2 5W max Supply Range 85 to 265VAC Qxx6 Qxx3 9 to 30VDC Qxx8 except Q448 18 to 30VDC Q448 10 8 to 26 8VDC Q404 12 to 35VDC Q501 Q510 Q520 6VDC min Q500 Agency Approvals UL CSA CE Part umber Function Input Span Field Configurable a Output Field Configurable DC Volts 10mV to 200V Q106 Limit Alarm DC Current 1mA to 100mMA Pt100 Pt500 Pt1000 50 to 850 C Cu10 Cu100 200 to 260 C Q116 Limit Alarm 3 Wire RTD Ni120 30 to 320 C NiFe604 200 to 240 C Type B 0 to 1820 C Type C 0 to 2320 C Type E 270 to 1000 C Type J 210 to 760 C Q126 Limit Alarm Thermocouple Type K 270 to 1372 C Type N 200 to 1300 C Type R 0 to 1760 C Type S 0 to 1750 C Type T 270 to 390 C Q403 1L08 DC Volts 0 to 10V Q403 1L09 isolators DC Volts 0 to 10V Q403 1L28 DC Volts 10 to 10V Q403 2L00 DC Current 2 Ch 4 to 20mA Q406 A000 DC VI 1 Ch Q406 A001 DC VI 1 Ch 24VDC Excitation Q406 A002 Isolators DC VI 1 Ch In 2 Out we Q406 A003 DC VI 1 Ch In 2 Out 24VDC Excitation Q406 A004 DC VI 2 Ch f DC Voltage 0 5V 0 10V w ice Pe ene see nanils DC Current 0 1mA 0 20mA 4 20mA 0 to 10mV up to 0 to 200mV R 5mV up to 200mV Q446 Isolator Strain Gauge 50 adjustment any range
14. 4 20mA i Output Signal PSIG Supply Air Input Pressure _w i Constant Pressure Voltage Source Amp Current Sensor Control COMMAND Current Sensing Amp Circuit Figure 1 IP51 IP61 Block Diagram IP51 2000 NEMA 4X 3 27 psig output IP51 3000 NEMA 4X 3 15 psig output IP51 4000 NEMA 4X 6 30 psig output IP61 2000 Explosion Proof 3 27 psig output IP61 3000 Explosion Proof 3 15 psig output IP61 4000 Explosion Proof 6 30 psig output TransPak T280 Isolating 2 Wire Transmitter for Pt100 RTD Thermocouple and mV e Miniature Thermal Head Mounted e 1000VDC Input to Output Isolation e Cost Effective Fixed Inputs e Eliminates Ground Loops e Hinged Cover Protects Potentiometers e Embedded Terminals Input Types Thermocouple B E J K L N R S T RTD Pt 100 2 wire or 3 wire mV 100mV max Input Span Thermocouple 5mV min span RTD 20 C min 500 C max mV 5mV min span Adjustability 15 for both zero amp span Output Span 4 20mA limiting lt 28mA Isolation 1000VDC Supply Voltage 10 to 40VDC polarity protected Operating Temperature 20 to 70 C Agency Approvals CE Specify T280 1xxx C F for RTD Input T280 2xxx tc type C F for thermocouple Input T280 3Xxxx for mV Input Accessories T25H 0000 Headmount enclosure 1 2 NPT for thermowell and conduit AP9046 ActionPak 24 40VDC 65mA Lo
15. ES Tools available 24VDC H910 H910 Power Supplies WV905 WV905 H915 H915 AP9046 AP9046 Ethernet Connectivity Potentiometer Configuration Tools available Most Complete Range of Legacy Models PC and Button Setup Fixed Connectors Removable Connectors WwWw eurotherm com actionio AC Limit Alarms and Signal Conditioners Q106 Q403 Q406 Q116 Q486 Q126 Q486 Q436 Q446 Q466 Q476 IQRL 2xxx required for AC power distribution Config Tools available ActionIQ DC Limit Alarms and Signal Conditioners Q108 Q404 Q408 Q498 Q488 Q488 Q438 Q448 Q468 Q478 Q498 IQRL Dxxx for DC power distribution Config Tools available Wide Ranging Input Math Capability W WW Loop Powered 2 3 Wire Transmitters amp Signal Conditioners Q500 Q501 Q510 Q425 Q520 I P TransPak VisiPak Current to Pressure Transducers IP51 IP61 Ideal for Hazardous Environments eurotherm 2 Wire Transmitters T280 T287 T700 T703 T713 T280 T287 T797 T798 T280 T287 T723 T797 T798 T287 T752 T761 T773 T287 requires c680 0001 Software and Adapter T609 Intrinsic Safety Models com actionio Digital Displays V108 V116 V132 V408 V430 V438 V560 V561 V565 V108 V116 V132 V408 V432 V108 V116 V132 V408 V432 V408 V438 V408 V434 V437 Intrinsic Safety Models Ultr
16. Eurotherm Pty Ltd Telephone 61 2 9838 0099 Fax 61 2 9838 9288 E mail info eurotherm com au AUSTRIA Vienna Eurotherm GmbH Telephone 43 1 7987601 Fax 43 1 7987605 E mail eurotherm eurotherm at BELGIUM amp LUXEMBURG Huy Eurotherm S A N V Telephone 32 85 274080 Fax 32 85 274081 E mail sales eurotherm belgium be BRAZIL Campinas SP Eurotherm Ltda Telephone 5519 3237 3413 Fax 5519 3234 7050 E mail eurothermltda eurothermltda com br DENMARK Copenhagen Eurotherm Danmark A S Telephone 45 70 234670 Fax 45 70 234660 E mail info eurotherm se FINLAND Abo Eurotherm Finland Telephone 358 22506030 Fax 358 22503201 E mail info eurotherm fi FRANCE Lyon Eurotherm Automation SA Telephone 33 478 664500 Fax 33 478 352490 E mail ea automation eurotherm co uk GERMANY Limburg Eurotherm Deutschland GmbH Telephone 49 6431 2980 Fax 49 6431 298119 E mail info regler eurotherm co uk HONG KONG amp CHINA Eurotherm Limited Aberdeen Telephone 85 2 28733826 Fax 85 2 28700148 E mail eurotherm eurotherm com hk Guangzhou Office Telephone 86 20 8755 5936 Fax 86 20 8755 5831 Beijing Office Telephone 86 10 6762 0936 Fax 86 10 6762 0931 Shanghai Office Telephone 86 21 6352 6406 Fax 86 21 6352 7351 INDIA Chennai Eurotherm India Limited Telephone 9144 24961196 Fax 9144 2256682070 E mail sales eurothermdel com IRELAND Dublin
17. Excitation 1 10VDC 120 mA AC Volts 50mV to 300V ance AC Current 5mA to 100mA See thermocouple types above Pt100 Pt200 Pt500 Pt1000 200 to 850 C Cu 9 035 40 to 260 C niversa Ni120 80 to 320 C meee isolator includes 2 3 amp 4 Wire RTD 90mV 900mV 0 to 4000 ohms 22 3mm Alarm Dual SPDT Relay 24VDC 20mA max Excitation Supply Alarm Dual SPDT Relay Alarm Dual SPDT Relay 4 to 20mA DC 0 to 10VDC 22 3mM 10 to 10VDC 4 to 20mA DC DC Voltage 0 5V 0 10V 22 3mm DC Current 0 1mA 0 20mA 4 20mA 0 20mA n a on dual outputs 22 3mm DC Voltage 0 5V 0 10V DC Current 0 1mA 0 20mA 4 20mA DC Voltage 0 5V 0 10V DC Current 0 1mA 0 20mA 4 20mA DC Voltage 0 5V 0 10V DC Current 0 1mA 0 20mA 4 20mA DC Voltage 0 10V DC Current 0 20mA 6 www eurotherm com actionio Housing Q500 1B00 Input DC Current 1 Ch Q500 2B00 Loop Powered DC Current 2 Ch 0 4 to 20mA 22 3mm 0 4 to 20mA DC Q500 4B00 Transmitters DC Current 4 Ch Output 0 to 1mA 0 to 20mA 4 to 20mA Q501 1Bxx DC VI 1 Ch 0 to 50mV 0 to 100mV 0 to 500mV Q501 2Bxx Loop Powered DC VI 2 Ch 0 to 1V 0 to 5V 1 to 5V 0 to 10V Oto 100V eeu fe AG SOM Oe Transmitters 10V Pt100 0 to 100 C 0 to 150 C 0 to 200 C RTD 2 Ch 0 to 250 C 0 to 500 C RTD 4 Ch Output Loop Powered Transmitters Q510 0Bxx Q510 4Bxx 4 to 20mA DC 0 to 200 F 0 to 300 F 0 to 400 F 0 to 500 F 0 to 1000 F
18. Output Adjustments Analog Zero 100 of Sensor Range Analog Full Scale Normal or Reverse Acting Operating Temperature Electronics and Display with reduced visibility 40 to 85 C Display full visibility 20 to 70 C Agency Approvals CSA FM Cenelek EEX 1797 0000 Temperature Transmitter Non IS 1797 1000 Temperature Transmitter IS FM CSA T798 0000 Temperature Transmitter HART Non IS T798 1000 Temperature Transmitter HART IS FM CSA TransPak Isolating 2 Wire Transmitters e Field Configurable Input Ranges e Wide Ranging Zero and Span e Eliminates Ground Loops e Rugged Metal Case TransPak two wire transmitters are compact rugged units that receive signals and direct sensor inputs and operate on power derived from the output signal loop The TransPak series provides a complete line of direct interface and conditioning modules for use with temperature pressure flow strain and other parameters TransPak transmitters also accept a wide range of other electrical DC and AC voltage and current inputs 1 20mMA 0 to 20mV DC Volts 0 to 200V DC Current 0 to 50mA ee 0 to 1mA min l 0 to 600 C T713 3 Wire RTD 200 to 360 C T703 Type J 0 to 760C 200 to 600 C Type K 0 to 1370 C 270 to 500 C T723 Thermocouple Type T 0 to 400 C 270 to 400 C Type E 0 to 1000 C 270 to 850 C Type R S 0 to 1760 T752 Potentiometer 50 ohms to 200k ohms pula 10 50mA T761 AC Volts 0 to 250V max 0 t
19. a SlimPak II DIN Rail Mount Signal Conditioners Isolators Alarms and Power Supplies e Ethernet Connectivity to Most Client e High Density Modules Software ds e Reduced Wiring with Jumpers e Built In Web Browser with Email and Transferring Power from Logging Capability Module to Module e PC or Button Setup and Calibration e Removable Connectors e Smart Power Technology Automatically e Fast Response amp High Accuracy Adjusts Power AO e In Process Calibration The Ultra SlimPak II Series can function as traditional stand alone limit alarms and isolators or they can simultaneously be connected to your company s intranet to monitor your signals via a standard browser when coupled with the optional WVC16 interface unit Isolation 1800VDC or peak AC between input output and power Operating Humidity 15 to 95 45 C Temperature Range Operating 0 to 60 C Storage 20 to 85 C Power Consumption 1 5W typical 2 5W max Supply Range 9 to 30VDC Agency Approvals UL CSA CE WV408 428 only Class 1 Div 2 Gp A B C D to 60 C ambient input Input Span Field Configurable fared Output Field Configurable DC Voltage 0 10V aL aR oN Oe ei ay 12 7mm DC Current 0 20mA 4 20mA 2 5mA 25mA oaa 95 adjustment in any range 20mV 200mV 2V 20V 200V 10MA 100MA Alarm Dual SPDT Relay DC Voltage 0 10V Isolator 2 3 amp 4 Wire RTD Platinum RTD 200 to 600 C 17 5mm
20. decades of proven success can assure you of our adherence to the highest quality standards and the best in manufacturing techniques Real World Ruggedness Action products are in tune with the industrial environment the real world of hard hats forklifts and EMI RFI they are ruggedized to survive the extremes of vibration shock temperature and humidity that are common to the manufacturing arena Action s Personal Commitment to Your Success We know how tough it is on the plant floor and we realize that every application has different requirements That s why Action s solutions are tailored to your problems Best Engineering Support in the Industry Experienced knowledgeable and friendly engineers are available throughout the world to answer your questions Think Reliable Think Smart Think Action Our goal is to be your exclusive supplier for industrial measurement and control products What can we offer you Plenty Wwww eurotherm What do Action Products Do Isolation A ground loop can occur if more than one ground connection Is made to a single control 4 i signal Because grounds are seldom at the Same potential an unwanted current will be generated and interfere with the control signal Signal isolators break the ground loop current path and maintain the integrity of the measurement Signal Conversion Industrial applications use a wide array of sensors to measure temperature flow length speed fr
21. equency etc These signals may then need to be converted into a form usable by the instrumentation to which they are connected Any sensor signal thermocouple RTD DC voltage DC current AC voltage frequency resistance etc can be converted to any standard process signal Noise Filtering J Isolators incorporate low pass filters that eliminate high frequency EMI RFI and unwanted signals from power lines generators and motors Linearization Many sensors output a signal that is not linearly related to the engineering value being measured For example a thermocouple used to measure temperature has a nonlinear millivolt output A thermocouple input signal isolator translates this to a standard robust linear signal such as 4 to 20 mA Limit Alarms Limit alarm units take in a process signal and compare it to one or more setpoints They then provide an output signal usually a relay contact when the signal crosses the setpoint Isolators that can perform addition subtraction multiplication division square root and averaging com actionio What is Signal Conditioning Signal conditioners are electronic instruments used in factory or machine automation They can amplify convert boost transform buffer filter alarm and isolate process control signals There seems to be no limit to the variety of things control engineers want to do with control signals Signal conditioners are known by many names con
22. ibrated output Supply Pressure Effect Not measurable within recommended supply pressure range Output Capacity 4 0 SCFM Supply and Exhaust Characteristics are balanced to within 10 Air Consumption 0 04 SCFM Steady State Average 0 06 SCFM Maximum Operating Temperature 20 to 150 F 29 to 66 C Temperature Effect lt 1 per 100 F 38 C change RFI EMI Effect Per SAMA PMC 33 1 standard b c 20 to 100MHz Class 3 effect on zero amp span less than 1 Operational Modes Direct reverse and or split range field selectable Agency Approvals CSA amp FM approved for hazardous environments www eurotherm com actionio OPERATION See Figure 1 The electric to pneumatic conversion takes place in the E Pi valve A conditioned 4 20 mA input signal provides a current to the coil of the E Pi This creates a magnetic field which magnetizes the valve The magnetization is proportional to the input current signal and positions the membrane relative to the valve seat The pneumatic output back pressure is thereby modulated relative to the input current Further conditioning of the pneumatic output Is achieved with a volume booster Final conditioning of the boosted pneumatic output signal is achieved by actually measuring the output with a pressure sensor This signal is then compared with the current to the E Pi to achieve the exact pneumatic output relative to the 4 20 mA current input Input Signal
23. n from Front Design for Quick Replacement Standard Power Supply 85 to 264VAC 48 to 62Hz or Optional 20 to 29VDC VAC Specify V408 ALGNVH V408 ALGNVL V408 ALRDVH V408 ALRDVL Accessories SUB2K D5 SUB2K D6 SUB2K R4 SUB2K TK SUB2K TL SUB2K TP SUB2K RR SUB2K LR SUB2K A2 SUB2K F2 SUB2K Y2 SUB2K MS SUB2K G3 SUB2K G5 1 8 DIN Green LED Display 85 264 VAC PS 1 8 DIN Green LED Display 20 29VDC VAC PS 1 8 DIN Red LED Display 85 264 VAC PS 1 8 DIN Red LED Display 20 29VDC VAC PS 2nd Input DC Retran Form C Relay Triple Contact Input Triple Logic Input Triple Logic Output Dual Relay Logic Relay 232 Communications 422 Communications 485 Communications 24VDC 20mA Excitation 5VDC Transducer Excitation 10VDC Transducer Excitation All units ship with mounting brackets a 2 49 ohm shunt resistor and a user manual com actionio VisiPak V560 V561 and V565 Loop Powered LCD Indicators V560 V565 e Eliminates Extra Power Supply e 3 1 2 Digit Display VisiPak V430 Series Digital Indicators e Field Configurable Input e NEMA 4X Front Panel e User Configurable Decimal Point e FM and CSA Approved These loop powered indicators provide a reliable solution regardless of environmental conditions The V560 and V565 are intrinsically safe and are approved by CSA and FM for use in hazardous locations either with safety barriers and the standard NEMA 4X housing or with the op
24. nd power Operating Humidity 15 to 95 45 C Temperature Range Operating 0 to 60 C Storage 20 to 85 C Power Consumption _1 5W typical 2 5W max Supply Range 9 to 30VDC and 120 or 240VAC 1080 1090 1280 1290 4380 4382 120 or 240VAC 4390 4391 4392 4081 6380 1690 7380 7500 7501 4003 4151 7510 120VAC only 4351 Agency Approvals UL CSA Manic ta eecaeenen cc ARAIBO Isolator tl Gy DC Volts 10mV to 100V 10 to 200V on AP4380 2001 DC Voltage 0 5V 0 10V AP4390 Isolator 2 Ch DC Current 1mA to 100mA DC Current 0 1mA 4 20mA DC Volts 10mV to 100V 5V to 5V Di Isolator 1 Ch Bipolar DC Current 1mA to 100mA 10V to 10V DC Volts 10mV to 100V Ch A 0 5V 0 10V or 0 1mA 4 20mA APAS Isolator 2 Ch 1 Bipolar DC Current 1mA to 100mA Ch B 5V to 5V or 10V to 10V i DC Volts 10mV to 100V 5V to 5V ARASI Isolator 2 Ch Bipolar DC Current 1mA to 100mA 10V to 10V AP1080 Limit Alarm 1 Ch DC Volts 10mV to 200V Single Trip 1 DPDT Relay 5A DC Volts AP1090 Limit Alarm 1 Ch DC Current 1mA to 100mA Single Dual Trip 2 SPDT Relay 5A revere icing Type B 500 to 1820 C DC Voltage 0 5V 0 10V ee Type E 150 to 1000 C DC Current 0 1mA 4 20mA Type J 200 to 700 C oie Thermocouple Type K 200 to 1370 C AP1280 Limit Alarm 1 Ch Type R 50 to 1760 C Single Trip 1 DPDT Relay 5A Type S 50 to 1760 C AP1290 Limit Alarm 1 Ch Type T 150 to 400 C Single Dual Trip
25. nts as low as 4mA reduces the chances of an electrical Spark causing ignition of flammable vapors or dust Additionally two wire transmitters save on wire costs 700 meters Q520 4 20mA Thermocouple Junction Digital Indicator Two wire Transmitter since both the signal and power are on the same wires Locating a two wire transmitter as far as 2000 feet from WwWw eurotherm com actionio the control room is possible and at half the wiring cost of a four wire transmitter It is important to note that two wire transmitters can be isolated or non isolated Many low cost two wire transmitters are not isolated which makes it important to ensure that the input sensor is not grounded All of Action s two wire transmitters are fully isolated Members of this group include the TransPak series and most of the Q5xx products Limit Alarms Limit alarms are considered a four wire transmitter since they have two wires for power and at least two wires for the relay signal output Limit alarms are similar to a thermostat On your thermostat at home you may have the temperature set to a cozy 72 F or 23 C If the room temperature falls below that setpoint the heater will turn on This is an example of on off control A limit alarm performs the same function It has a setpoint which is compared to a process signal If the temperature gets too high the limit alarm is used to alert an operator or shut down the process Othe
26. o 2mV min 4 20MA AC Current 0 to 2A max 0 to 80uA min 10 50mA 4 20mA 1700 0001 T703 2000 T713 0000 1713 0013 1723 0000 1723 0001 1752 0000 T761 0000 1773 0000 Accessories 1 20mA 4 20mA 4 20mA 10 50mA 4 20mA 10 50mA Loop Powered Isolator DC Input 2 Wire Transmitter RTD 0 to 600 C Input 2 Wire Transmitter RTD 200 to 360 C Input 2 Wire Transmitter T C Q K T Input 2 Wire Transmitter T C E R S Input 2 Wire Transmitter Potentiometer Input 2 Wire Transmitter AC Input 2 Wire Transmitter Frequency Input 2 Wire Transmitter Displays and Options M004 Snap in Channel Track 4ft T902 Mounting Plate for M004 includes 4 track T910 Bulkhead flat surface Mounting Plate T805 Explosion Proof NEMA 4 Enclosure AP9046 Action Pak 24 40VDC 65mA Power Supply T609 24VDC 600mA Power Supply V565C 3 1 2 digit remote loop powered indicator Wide ranging display NEMA 4X enclosure CSA T79A CO00 Configuration Software for T797 and T798 T79A D000 DIN Rail Mounting Kit T79A MO00 T797 Configuration Modem T79A MHOO T798 HART Configuration Modem T79A P000 Pipe Mount Bracket for T79E 0 D only T79D 1000 One Line Alphanumeric Display T79D 2000 Two Line Alphanumeric Display T79E 1000 Weatherproof Head mount Enclosure www eurotherm and FM approval 11 com actionio VisiPak V108 V116 and V132 Temperature Process Indicators VisiPak V408 Universal Temperature Pressure Process Indicators
27. op Power Supply T609 24V 600mA Loop Power Supply V560 565 3 1 2 digit Remote Loop Powered Indicator with wide ranging display www eurotherm TransPak T287 Programmable Isolating Universal Input 2 Wire Transmitter PC Based User Friendly Configuration 2000VDC Input to Output Isolation Universal Input Reduces Inventory Custom Linearization for Special T C Types and Math Single or Dual Inputs DIN Rail Mounting Adapter Included Input Types Thermocouples Most standard types amp all special types using customer defined tables amp polynomials RTD 2 3 amp 4 wire Pt 100 Ni 110 Ni 120 amp other RTDs Includes Callandar Van Dusen adaptation and custom sensors linearization with user defined tables and polynomials DC mV 10 to 100mV Potentiometers 0 to 20k Ohms Resistance 0 to 400 Ohms Infrared Minimum Range 2mV Output 4 20mA Supply Voltage 9 40VDC no load polarity protected Operating Temp 40 to 85 C Isolation 2000VDC input to output Calibration Unit includes all calibration parameters performs periodic zero and span self test and auto calibration Agency Approvals CE Specify 1 Model 7287 0000 2 Model C680 0001 Isolated Communications Adapter Configuration and Calibration Software and User s Guide Accessories T25H 0000 Headmount enclosure 1 2 NPT for thermowell and conduit AP9046 ActionPak 24 40VDC 65mA Loop Power Supply T609 24V 600mA
28. r applications include limit alarms that can also act as backup for a control system to perform a controlled shutdown process in order to prevent damage or other hazards WvV408 Ultra SlimPak II Digital Indicators Digital indicators or panel meters will also accept direct sensor inputs For the most part AC powered indicators can be considered a four wire transmitter if they are configured with an analog or relay output Indicators are most commonly used to display process variables however some have secondary functions such as a 4 20mA transmitter output limit alarm or relay contact closure output Loop powered indicators such as Action s V560 are an important type of digital indicator These indicators are designed for field use and have operating characteristics similar to a two wire transmitter They use a 4 20mA signal for power and therefore as low power devices are ideal for use in hazardous environments VisiPak V408 1 8 DIN Rail Mount Indicator Product Selection Guide Ultra SlimPak II Ultra SlimPak ActionPak i i ir A a7 j 7 Input ae a Type it at i S Limit Signal imi Signal Limit Signal Alarms Conditioners Conditioners Alarms Conditioners AP4380 AP4382 An WV108 PETOCO 5 AP4390 4391 4392 urrent _AP1090 AP750x RTD WV118 WV418 NS Te 7 Wes APS Thermocouple 2 AP1280 AP4351 a B Strain Gauge E AP4081 AC Volts WV168 AP1690 AP6380 eo AP7380 tomy B o k NO A Configuration CCESSON
29. r unique solid state current to pressure converter uses minimal electrical energy and air consumption to produce accurate output pressure signals Because there are no moving parts the unit will operate reliably for many years when installed properly These transducers are available in a NEMA 4X housing IP51 or in an Explosion Proof housing IP61 They are rated Intrinsically Safe and are available with FM approval standard and CSA approval optional Input 4 20MA Output 3 27 3 15 6 30 PSIG Accuracy 3 15 PSIG 0 15 of Span 3 27 6 30 PSIG 0 25 of Span Repeatability 0 05 of Span Deadband 0 02 of Span Stability Reproducibility 0 5 of Span 6 months Position Effect Not Measurable Vibration Effect lt 0 25 from 1 200H7 1g Frequency Response 3db at 5Hz per ISA S26 4 3 1 Configuration A Loop Load 3 8VDC 5 ohms 195 ohm load at 20mA Operating Current 3 7mA min 200mA max continuous at 120 F Half Cycle 70 amp 1 20sec at 68 F Failure Mode Transducer always fails in the direct mode i e if input current drops below 3 7mA DC the output will drop to 1 to 2 psig regardless of direct or reverse mode selection Enclosure Internally purged NEMA 4X Cast Machined Aluminum with powder coat epoxy Connections 1 4 NPTF supply port 1 1 4 NPTF output Port 2 1 2 NPTF electrical conduit connection Weight 2 5 Ibs Supply Pressure Minimum of 3 psig and maximum of 10 psig above the maximum cal
30. responsibility for damage injury or loss expenses resulting from this document HA136737 Issue 3
31. tional explosion proof housing Because of its low voltage drop of only 1 volt the V565 can provide an extra 3 5 volts of loop drive above standard loop powered indicators The small V561 explosion proof loop powered indicator is ideal for pipe mount e 4 Visual Alarm Points with Front Panel LED Status e Wide Ranging Displays The V430 Series has an indicator for every application All V430 Series indicators have options for dual relay contact outputs and 4 20mA outputs as well as full field programmability applications The optional backlight sheds light on those dark hazardous locations V560 565 Specify V560 0014 0 V565 0000 0 Loop Powered Indicator 4 20 or 10 50mA Out High Performance Loop Powered Indicator 4 20 or 10 50mA Out V560 565 Options Option C Conduit Housing for Internal Mounting of T600 T700 Transmitter Option EP Explosion Proof Housing Option U Urethane Coating of Internal Circuitry Option C620 Factory Calibration specify range Option T901 TransPak Mounting Plate for Option EP Option T906 TransPak Mounting Plate for Option C Option V860 Conduit Mounting Kit Option V906 Explosion Proof Mounting Kit V561 Specify V561 0000 V561 1000 Loop Powered Explosion Proof LCD Indicator Loop Powered Explosion Proof LCD Indicator with Backlight www eurotherm Specify V430 0000 1 DC VI Rate Total 120VAC V430 1000 1 DC VI Rate Total 120VAC 2 Relays V430 2000 1 DC VI Rate Total 120VAC
32. verters transducers isolators transmitters and black boxes Conventionally most signal conditioners and isolators fall into two categories based on the number of wires required for power and signal Four wire Transmitters A four wire transmitter has two wires for power and two wires for the signal output A four wire transmitter can be either AC or DC powered Four wire transmitters provide a powered output either a voltage signal e g 0 10V 1 5V a current signal e g 4 20mA 10 50mA or in some cases a relay e g solid state or contact closure Four wire transmitters require a power supply they do not use power from the input or output signal lines The power supply allows four wire transmitters to power their output signal Because of this they are often used to boost signal strength for retransmission 700 meters Thermocouple Junction 4 20mA Digital Indicator Four wire Transmitter Two wire Transmitters A two wire transmitter is powered by the same two wires that carry the output signal A two wire transmitter Is always DC powered and the output can only be a current signal typically 4 20mA or sometimes 10 50mA The two wire transmitter is considered a field device and requires very little power milliwatts It is therefore appropriate for hazardous explosive environments such as chemical refineries and pharmaceutical plants The low DC power requirement which ranges from 10 48VDC at curre