A-A1S Module Conversion Adapter User`s Manual
Contents
1. Na e l A1ADP SP AnS series Ho de BS a special function module 8 HO o Ho o Co Co o o ao amomo 9 O 2 2 2 Available Base Units List The following table shows the base units to which the A1ADP can be installed Up to three A1ADPs can be installed to one base unit Extension base unit T Number of installable Remarks ype adapters A68B Install the QA6ADP to an extension main base unit However the modules that can be installed to have restrictions For details refer to the QA6ADP QA Conversion Adapter Module User s Manual 0 PN W W OO WH N GW The modules that can be installed to have restrictions For details refer to the QA65B QA68B Extension Base Unit User s Manual eo 2 2 3 Available CPU modules list The following table shows the CPU modules available for the A1ADP use Available CPU module Q02CPU QO2HCPU QO6HCPU Q12HCPU Q25HCPU 2 3 Precautions for Use 1 When replacing the A large type series module by the A1ADP AnS series module the internal current consumption may increase At replacement make sure to check the 5VDC internal current consumption of the modules before and after replacement If the 5VDC internal current
2. Not used A62DA 600mA A1S62DA 800mA 1 External wiring Changed Terminal block is different 2 Number of slots Not changed 3 Program I O signals and buffer memory address are changed 4 Performance specifications change I O characteristics and conversion time 5 Function specifications Not changed 6 Since internal current consumption increases by combination with the A1ADP SP checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 SP 47 Analog output module Related model for discontinuation Transition to the AnS series A series model A62DA S1 A68DAI S1 150mA AnS series model A1S62DA A1S68DAI 850mA A1S68DAV A 1 2 3 4 5 6 Restrictions External wiring Changed Terminal block is different Number of slots Not changed Program I O signals and buffer memory address are changed Performance specifications change I O characteristics and conversion time Function specifications Not changed Since internal current consumption increases by combination with the A1ADP SP checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 External wiring Changed Terminal block is different Number of slots Not changed Program I O signals and buffer memory address are changed Performance specifications change Output current range I O characterist
3. Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc Hong Kong Mitsubishi Electric Automation 500 Corporate Woods Parkway Vernon Hong Kong Ltd Hills IL 60061 U S A 10th Floor Manulife Tower 169 Electric Tel 1 847 478 2100 Road North Point Hong Kong Brazil MELCO TEC Rep Com e Assessoria Tel 852 2887 8870 A China Mitsubishi Electric Automation Tecnica Ltda Shanghai Ltd Rua Correia Dias 184 J
4. For fixing the AnS series module insert the module fixing projection into the module fixing hole Forceful installation may damage the module connector and or A1ADP 15 2 AnS series module removal Remove the module mounting screw Pull the upper AnS series module forward with placing its underneath as a fulcrum Lift upwards and remove the module hook from the module fixing hole Completed POINT For removing the AnS series module untighten the module mounting screw first and then remove the module fixing projection from the module fixing hole Forceful installation may damage the module connector and or A1ADP A1ADP AnS series module 16 6 EXTERNAL DIMENSIONS The external dimensions of the A1ADP are shown below A1ADP XY A1ADP SP o 8 N o A AE ES A A1ADP XY Atapp a O O Oo O o MITSUBISHI MITSUBISHI WO Y 37 5 1 48 When a module is installed 4 2 m 4 2 0 17 0 17 2 a A ao g8 m gS NS eal Ab gt PAEZ BIT Er al lol IES 2 ad K Y 6 RiE gt 32 Fa ae 42 355 93 6 3 69 el 4 2 35 5 p 93 6 3 69 223 0 17 1 40 129 1 5 08 0 17 1 40 452 1 5 99 0 91
5. checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 Program Number of occupied l O points Not changed 32 16x2 Specifications Rated output voltage Not changed Rated output current Not changed However contact life span is reduced to half 230mA Functions Changed No fuse AY13EU A1SY10EU A External wiring Changed Number of slots Changed 2 modules required Since internal current consumption increases by combination with the A1ADP XY when using the two modules checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 Program Number of occupied l O points Not changed 32 16x2 Specifications Rated output voltage Not changed Rated output current Not changed However contact life span is reduced to half Functions Not changed 35 Product Related model for discontinuation Transition to the AnS series A series model AY15EU AnS series model A1SY14EU 120mA Restrictions External wiring Changed Number of slots Changed 2 modules required Since internal current consumption increases by combination with the A1ADP XY when using the two modules checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 Program Number of occupied l O points Not changed 32 16x2 Specifications Rated output voltage Not changed Rated output current Not changed However contact life span is
6. Edificio Paraiso Trade Center 8 andar s n Fu Plazz No 80 An Chang Road z Shanghai 200003 China Paraiso Sao Paulo SP Brazil Tel 86 21 6120 0808 Tel 55 1 1 5908 8331 Taiwan Setsuyo Enterprise Co Ltd Germany Mitsubishi Electric Europe B V German 6F No 105 Wu Kung 3rd Rd Wu Ku Branch Hsiang Taipei Hsine Taiwan Gothaer Strasse 8 D 40880 Ratingen Tel 886 2 2299 2499 GERMANY Korea Mitsubishi Electric Automation Korea Tel 49 2102 486 0 Co Ltd U K Mitsubishi Electric Europe B V UK 1480 6 Gayang dong Gangseo ku Branch Seoul 157 200 Korea Travellers Lane Hatfield Hertfordshire Tel 82 2 3660 9552 AL10 8XB U K Singapore Mitsubishi Electric Asia Pte Ltd h 2 7 307 Alexandra Road 05 01 02 Tel 44 1707 276100 Mitsubishi Electric Buildi Italy Mitsubishi Electric Europe B V Italian i SUSS eo urang Branch ngap ore C Dir Colleoni Pal P iora Tel 65 6470 2460 entro Dir Colleoni Pal Perseo Ingr Thailand Mitsubishi Electric Automation Thailand Via Paracelso 12 l 20041 Agrate Brianza Co Ltd Milano Italy Bang Chan Industrial Estate No 111 Tel 39 039 60531 Moo 4 Serithai Rd T Kannayao Spain Mitsubishi Electric Europe B V Spanish A Kannayao Bangkok 10230 Thailand Branch Tel 66 2 517 1326 Carretera de Rubi 76 80 Indonesia P T Autoteknindo Sumber Makmur E 08190 Sant Cugat del Valles Muara Karang Selatan Block A Utara Barcelona Spain No 1 Kav No 11 Kawasan Industri Tel 34 93 565 3131
7. O e B E Extension base unit o ITTTIT TTT irr tir it CITTITIT TTT IT TTT iTt A1ADP SP AnS series o o o o i Q Eni i i o special function module ga i o o o E l E M1 o TA 2 1 2 Available Base Units List The following table shows the base units to which the A1ADP can be installed Up to three A1ADPs can be installed to one base unit Extension base unit Type Number of installable Type Number of installable adapters adapters A38B 3 A68B 3 A38B E 3 A68B UL 3 A38B UL 3 A65B 3 A38HB 3 A65B UL 3 A38HBEU 3 A62B 2 A35B 3 A58B 3 A35B E 3 A58B UL 3 A35B UL 3 A55B 3 A32B 2 A55B UL 3 A32B E 2 A52B 2 A32B UL 2 A68RB 3 A32B S1 2 A33RB 2 A32RB 1 2 1 3 Available CPU modules list The following table shows the CPU modules available for the A1ADP use A1NCPU A2NCPUP21 Available CPU module A1NCPUP21 A1NCPUR21 A2NCPUR21 A2NCPU S1 A2NCPU A2NCPUP21 S1 A4UCPU A3NCPUP21 S3
8. input signals Only plus current can be input 5 Function specifications Multiplexer function 1000mA not available External wiring Changed Terminal block is different Number of slots Not changed Program I O signals and buffer memory address are changed Performance specifications change I O characteristics Function specifications Setting method of the A D conversion disable function has been changed Since internal current consumption increases by combination with the A1ADP SP checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 A68AD S2 A1S68AD External wiring Changed Terminal block is different Number of slots Not changed Program I O signals and buffer memory address are changed Performance specifications change I O characteristics Function specifications Not changed Since internal current consumption increases by combination with the A1ADP SP checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 A1S68AD External wiring Changed Terminal block is different Number of slots Not changed Program I O signals and buffer memory address are changed Performance specifications change I O characteristics and resolution Function specifications Not changed 46 Product Multi plexer Analog output module Related model for discontinuation Transition to the AnS series A series model A60MX 650mA
9. 17 Unit mm inch 7 COMPATIBLE MODELS LIST This section describes the AnS series modules that can be installed to the A1ADP Product Mounting of the A1ADP QCPU QnACPU ACPU Applicable adapter Input module Output module Mounting of the A1ADP field A1SX10 O XY A1SX10EU O XY A1SX20 O XY A1SX20EU O XY A1SX30 O XY A1SX40 O XY A1SX40 S1 O XY A1SX40 S2 O XY A1SX41 O XY A1SX41 S1 O XY A1SX41 S2 O XY A1SX42 O XY A1SX42 S1 O XY A1SX42 S2 O XY A1SX71 O XY A1SX80 O XY A1SX80 S1 O XY A1SX80 S2 O XY A1SX81 O XY A1SX81 S2 O XY A1SX82 S1 O XY A1SY10 O XY A1SY10EU O XY A1SY14EU O XY A1SY18A O XY A1SY18AEU O XY A1SY22 O XY A1SY28A O XY A1SY40 O XY A1SY40P O XY A1SY41 O XY A1SY41P O XY A1SY42P O XY A1SY50 O XY A1SY60 O XY A1SY60E O XY A1SY68A O XY A1SY71 O XY A1SY80 O XY A1SY81 O XY A1SY82 O XY O Mountable x Not mountable Applicable adapter field XY A1 ADP XY SP A1ADP SP Not available 18 Product Model Mounting of the A1ADP QCPU QnACPU ACPU Applicable adapter A1SH42 O XY A1SH42P O XY A1SH42 S1 O XY Omer A1SH42P S1 O XY A1SX48Y58 O XY A1SX48Y18 O XY A1SJ 56DR x a A1SJ 56DT x E Dynamic scan input module A1S42X O X
10. A1ADP Tighten two adapter mounting Es Two adapter screws after confirming that the Z fixing projections hook on the A1ADP is fully inserted into the module fixing hole A on the base unit Completed Base unit A1ADP Adapter mounting screw For fixing the A1ADP insert the adapter fixing projections into the module fixing holes B Forceful installation may damage the module connector and or A1ADP 12 2 A1ADP removal Untighten two adapter Module fixing hole A mounting screws Base unit f While holding the A1ADP with both hands push the adapter fixing hook with fingers until it stops While pushing the hook pull the A1ADP foward placing the lower part of the A1ADP as a supporting point Lift the upper part of the A1ADP and remove the adapter fixing projections from the module fixing holes B Completed POINT Before removing the A1ADP make sure to untighten two adapter mounting screws Then remove the adapter fixing hook from a module fixing hole A and also the adapter fixing projections from a module fixing holes B Forcefully removing the adapter may damage the adapter fixing hook and or the adapter fixing projections 13 5 2 2 Installing removing the dustproof cover Before installing the AnS series module to the A1ADP attach the dustproof cover for the A1ADP XY SP included with the A1ADP to the module If no dustproof cover is attach
11. A1ADP are listed below Quantity A A1S module A1ADP XY or 4 conversion adapter A1ADP SP The dustproof cover for A1ADP is shown the A1ADP XY SP 1 on the backside of the dustproof cover This manual o _ 1 For references of the dustproof cover see the back cover of this manual 1 3 Related Parts Sold Separately When the A large type module has been installed on the right of a slot to which the A1ADP has been loaded attach the following dustproof cover to the A large type series module side The following dustproof cover is not an accessory Please purchase it separately Quantity Same dustproof cover included in the A52B Mitsubishi Electric I O dustproof cover System Service Co Ltd A55B and A58B For references of the dustproof cover see the back cover of this manual 2 SYSTEM CONFIGURATION The A1ADP can be installed to the following base units e A QnA large type series main base units or extension base units e A series extension base units installed to Q series base units This section describes the system configuration available base units available CPU modules and precautions for the A1ADP 2 1 For installing the A1ADP to an A QnA large type series main base unit or extension base unit 2 1 1 System Configuration A1ADP XY o C33 a AnS series o J 0 0 o v n I O module U H H B y do Al FE O
12. AnS series model None Restrictions Alternating with multiple A1S68AD modules is recommended Applicable adapter Not used AGOMXRN 350mA None Using multiple A1S68ADs and perform isolation between channels is recommended Not used A60MXR 500mA None Using multiple A1S68ADs and perform isolation between channels is recommended Not used AGOMXTN 640mA None Alternating with multiple A1S68TD modules is recommended Not used AGOMXT 800mA None Alternating with multiple A1S68TD modules is recommended Not used A616DAI 300mA None Using the A1S68DAI is recommended 1 External wiring Changed Terminal block is different 2 Number of slots Changed 2 modules required 3 Program I O signals and buffer memory address are changed 4 Performance specifications change 8CH module input current range 5 Function specifications The relation between the D A conversion disable channel and the conversion time is changed Not used A616DAV 380mA None Using the A1S68DAV is recommended 1 External wiring Changed Terminal block is different 2 Number of slots Changed 2 modules required 3 Program I O signals and buffer memory address are changed 4 Performance specifications change 8CH module resolution and accuracy 5 Function specifications The relation between the D A conversion disable channel and the conversion time is changed
13. O points Not changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Changed Fuse not replaceable Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to 120mA POINT 1 to 3 A1SY81 External wiring Changed Connector terminal block must be converted Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated output voltage Not changed Rated output current Changed Output 0 5A gt 0 1A Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to 230mA 500mA POINT 1 to 3 43 Product 1 0 module Related model for discontinuation Transition to the AnS series A series model AY82EP AnS series model A1SY82 A1SH42 A1SH42P Restrictions External wiring Changed D sub FCN connector Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 External wiring Not changed Number o
14. O x SP A1SJ71QE71N3 T x O x SP A1SJ71QC24N x O x SP E A1SJ71QC24N R2 x O x SP Serial communication module A1SJ71QC24N1 x O x SP A1SJ71QC24N1 R2 x O x SP MELSECNET B data link module o IB ES 2 gt SE A1SJ72T25B x a MELSECNET data link module AI Staats Z 2 Q E A1SJ71AR21 x O O SP MELSECNET MELSECNET B Sa 2 as O A1SJ71AR23Q O x x SP local station data link module A1SJ71AT23BQ O x x SP CC Link system master local A1SJ61BT11 x x O SP module A1SJ61QBT11 O O x SP MELSECNET MINI S3 master module A1SJ71PT32 S3 O SP MELSEC I O LINK master module A1SJ51T64 O SP JEMANET OPCN 1 interface A1SJ71J92 S3 O SP module A1SJ72J95 x a B NET interface module A1SJ71B62 S3 O SP A1SJ71UC24 R2 x O O SP Computer link module A1SJ71UC24 PRF x O O SP A1SJ71UC24 R4 o O O SP AS i master module A1SJ71AS92 O Modem interface module A1SJ71CMO S3 O PC fault detection module A1SS91 O Memory card interface module A1SD59J S2 O ID interface module BisbssI0 2 A1SD35ID2 O MODBUS module A1SJ71UC24 R2 S2 O A1SJ71UC24 R4 S2 O Profibus DP interface module AATE AR 2 A1SJ71PB93D O Profibus FMS interface module A1SJ71PB96F O DeviceNet master module A1SJ71DN91 O Mounting of the A1ADP field O Mountable x Not mountable Applicable adapter field XY A1ADP XY SP A1ADP SP_ Not available 1 Take care since the combination of the module type configured in the I O assignment setting and the A1ADP model that can be combined differs 2 The adapter is mo
15. OFF voltage OFF current Changed Input resistance Changed Functions Not changed 27 Related model for Transition to the AnS series Product discontinuation A series AnS series Rastictions Applicable model model adapter AX60 S1 Alternating with A1SX40 is recommended 1 External wiring Changed Connect a 15kQ 3W or more to the external signal wire serially Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated input voltage Changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed A1SX71 External wiring Changed Connector terminal block must be converted Number of slots Not changed Program Number of occupied O points Changed Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to 75mA POINT 1 to 3 A1SX71 External wiring Changed Connector terminal block must be converted Number of slots Not changed Program Number of occupied O points Changed Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current C
16. Pergudangan Jakarta Utara 14440 _ France Mitsubishi Electric Europe B V French P O Box 5045 Jakarta 11050 Indonesia Branch Tel 62 21 6630833 India Messung Systems Pvt Ltd ae eee Electronic Sadan NO III Unit No15 AMENE eee ance M I D C Bhosari Pune 411026 India TEL 33 1 5568 5568 Tel 91 20 2712 3130 South Africa Circuit Breaker Industries Ltd Australia Mitsubishi Electric Australia Pty Ltd Private Bag 2016 ZA 1600 Isando 348 Victoria Road Rydalmere South Africa N S W 2116 Australia Tel 27 11 928 2000 Tel 61 2 9684 7777 aMITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN Specifications subject to change without notice Printed in Japan on recycled paper
17. block is different Number of slots Changed 4 modules required Program Changed Performance specifications change 2CH module 940mA Function specifications Not changed A68RD4N None x Using the A1S62RDAN is recommended Not used 1 External wiring Changed Terminal block is different Number of slots Changed 4 modules required Program Changed Performance specifications change 2CH module 410mA Function specifications Not changed AD61 A1SD62 External wiring Changed SP Terminal block is different Number of slots Not changed Program Buffer memory address is changed Performance specifications change Upward compatibility Function specifications 300mA 100mA Upward compatibilit AD61 S1 A1SD62 External wiring Changed SP Terminal block is different Number of slots Not changed Program Buffer memory address is changed Performance specifications change Upward compatibility Function specifications 100mA Upward compatibilit 49 Related model Product discontinuation model model adapter Positioning AD70 A1SD70 1 External wiring Changed Terminal block i Not used module different 2 Number of slots 1 slot 2 slots 3 Program Not changed 4 Performance specifications change Not changed 300mA 300mA 5 Function specifications Not changedv AD72 None x No alternative model Not used 900mA AD75M1 A1SD75M1 No restrictions SP The A1SD75 C01HA cable is required since the pe
18. causes malfunctions a failure or drop Tightening the screw excessively may damage the screw and or adapter resulting in a drop of the adapter and installed module short circuit or malfunctions O Be sure to shut off all phases of the external supply power used by the system before installing or removing the adapter Failure to do so may damage the products e Do not directly touch the conductive part or electronic components of an adapter Doing so may cause malfunctions or a failure of the adapter WIRING PRECAUTIONS O Be sure to shut off all phases of the external supply power used by the system before wiring Failure to do so may result in an electric shock or damage of the product e Before energizing and operating the system after wiring be sure to attach the terminal cover supplied with the product Failure to do so may cause an electric shock CAUTION Wire the module correctly after confirming the rated voltage and terminal layout Connecting a power supply of a different voltage rating or incorrect wiring may cause a fire or failure Do not connect multiple power supply modules to one module in parallel The power supply modules may be heated resulting in a fire or failure O Press crimp or properly solder the connector for external connection with the specified tool Incomplete connection may cause a short circuit fire or malfunctions A 2 WIRING PRECAUTIONS CAUTION e Tighten terminal scre
19. gt M3 5 Number of slots Not changed Program Number of occupied l O points Not changed Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed Applicable adapter A1SX20 50mA A1SX20 50mA A1SX20EU External wiring Changed Screw size M3 gt M3 5 Number of slots Not changed Program Number of occupied l O points Not changed Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed External wiring Changed Screw size M3 gt M3 5 Number of slots Changed 2 modules required Program Number of occupied I O points Not changed 32 16x2 Specifications Rated input voltage Changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed External wiring Changed Number of slots Changed 2 modules required Program Number of occupied I O points Not changed 32 16x2 Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed 24 Related model Product discontinuation A series Ans series
20. mm inch 1 Depth dimension of the A series 32 point terminal block module 2 Depth dimension of the A1ADP AnS series 32 point connector type module 3 Consider the bending radius of a connector cable 5 The AnS series output module with a fuse detects fuse blown if external supply power has not been input Use special relay M9084 or SM1084 error check at power on with the external supply power OFF so that fuse blown may not be detected 6 When mounting the A1ADP XY AnS series output module with a fuse on the MELSECNET II remote I O station AJ72P25 or AJ72R25 the CPU module of the master station may detect UNIT VERIFY ERR However note that the AJ72P25 or AJ72R25 whose software version is P or later is used UNIT VEFIRY ERR will not be detected Turning ON the power supply of the master station after turning ON the power supply of the remote I O station and the 24VDC external power supply enables to avoid UNIT VEFIRY ERR Also if the fuse blown is detected cancel the error by the reset operation of the CPU module used 3 SPECIFICATIONS 3 1 Performance Specifications The performance specifications of the A1ADP are shown below Specification A1ADP XY A1ADP SP 5VDC internal current consumption 3 4mA OmA 250 H x37 5 W x35 5 D Extemaralmensions 9 84x1 48x1 40 mm inch Weight 0 20kg 4 PARTS NAMES Each part name of the A1ADP is shown in the table below Module installing side Base un
21. output current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed 5 Functions Not changed Dummy AG62 A1SG62 O No restrictions 60mA module Al61 A1SI61 1 External wiring Changed 2 Number of slots Not changed 3 Program Number of occupied I O points Not changed 4 Specifications Rated output voltage Not changed Rated output current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Changed Interrupt processing condition can be set 140mA 57mA in 4 point unit Al61 S1 A1SI61 External wiring Changed Number of slots Not changed Program Number of occupied I O points Changed 16 points occupied Specifications Rated output voltage Not changed Rated output current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed 5 Functions Changed Interrupt processing condition can be set in 4 point unit 140mA 57mA 6 Others The response time is different 45 Related model for Transition to the AnS series discontinuation A series AnS series Re trictions Applicable model model adapter A616AD Using the A1S68AD is recommended 1 External wiring Changed Terminal block is different 2 Number of slots Changed 2 modules required 3 Program I O signals and buffer memory address are changed 4 Performance specifications change 8CH module
22. reduced to half Functions Not changed Applicable adapter A1SY22 270mA External wiring Changed Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated output voltage Not changed Rated output current Changed Output 2A 0 6A Functions Changed No fuse no varistor A1SY22 External wiring Changed Number of slots Changed 2 modules required Program Number of occupied I O points Not changed 32 16x2 Specifications Rated output voltage Not changed Rated output current Not changed Functions Changed No fast blow fuse 36 Related model for Transition to the AnS series Product discontinuation A series Ans series Applicable model model Sec None adapter A1SY40P External wiring Changed Number of slots Not changed 79mA AY40 UL A1SY40P 79mA Program A1SY68A 110mA Number of occupied I O points Not changed A1SY41P 141mA Specifications Rated output voltage Not changed Rated output current Not changed Functions Not changed External wiring Changed Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Not changed External wiring Changed Number of slots Changed 2 modules required Since internal current consumption increases by combination with the A1ADP XY when using the t
23. to the end user DESIGN PRECAUTIONS DANGER When using the A series module to which the A A1S module conversion adapter has been installed on the right side attach a dustproof cover to the module If no dustproof cover is attached foreign matter will enter the module resulting in a failure Furthermore internal parts of the module may be flied in the short circuit test or when an overcurrent or overvoltage is accidentally applied to the external I O section O Before installing the AnS series module to the A1ADP attach the dustproof cover to the module If no dustproof cover is attached foreign matter will enter the module resulting in a failure Furthermore internal parts of the module may be flied in the short circuit test or when an overcurrent or overvoltage is accidentally applied to the external I O section A 1 INSTALLATION PRECAUTIONS CAUTION Use the programmable controller in the environment given in the general specifications section of the User s manual for CPU module being used Using the programmable controller outside the range of the general specifications may result in electric shock fire or erroneous operation or may damage or degrade the product e Fully insert adapter fixing projections on the lower part of an adapter into fixing holes on the base unit then tighten the adapter mounting screw within the specified torque If the adapter is not correctly installed or no screw is tightened it
24. whether any restriction is given or not when mounting the A1ADP AnS module A module with the name provided in the Model column No restrictions Partially restricted The restriction outline is described in the Remark restrictions column No alternative model The alternating method is described in the Remark restrictions column x A as for The performance specifications are compatible while the module cannot specifications be mounted due to the expanded module width x v Indicates an installable A1ADP model XY A1ADP XY An adapter only for I O modules SP A1ADP SP An adapter only for special function modules Not used Either of the A1ADPs cannot be installed POINT 1 When replacing the A series module by the A1ADP AnS series module the internal current consumption may increase At replacement make sure to check the 5VDC internal current consumption of the modules before and after replacement If the 5VDC internal current consumption increases after the replacement confirm that the current consumption of the modules used does not exceed the rated output current of the power supply module used 2 If the A1ADP AnS series module is mounted to an extension base unit type requiring no power supply module A52B A55B or A58B when 5VDC internal current consumption is increased voltage drop increases in the extension cable Therefore recalculating the receiving end voltage is required For confirm
25. 5mA AY11AEU A1SY18A External wiring Changed EU Number of slots Changed 2 modules required Program Number of occupied l O points Changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Changed No varistor Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 33 Product Related model for discontinuation Transition to the AnS series A series model AY11EEU 115mA AnS series model A1SY10 A1SY10EU 120mA Restrictions External wiring Changed Number of slots Not changed Program Number of occupied l O points Not changed Specifications Rated output voltage Not changed Rated output current Not changed However contact life span is reduced to half Functions Changed No fuse no varistor Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 External wiring Changed Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated output voltage Not changed Rated output current Not changed However contact life span is reduced to half Functions Changed No fuse no varistor Since internal current consumption increases by combination with the A1ADP XY checkin
26. 80mA AS25VS None x Connecting a commercially available Not used vision sensor and programmable 2620mA AS50VS None x Not used 3300mA controller with RS232 Ethernet or Digital I O for data loading is recommended Connecting a commercially available vision sensor and programmable controller with RS232 Ethernet or Digital I O for data loading is recommended 1 When the ANACPU communicates in nonprocedural mode using the dedicated instructions PR PRN INPUT turn on the transmission specification setting switch SW03 on the module of software version X or later If the software version of the module is W or earlier use the FROM TO instructions for communication There are no restrictions when the AnACPU communicates in nonprocedural mode using the FROM TO instructions or the used CPU module is except the AnACPU 54 8 3 List of Transition from the QnA Series to AnS Series Product Ethernet module Serial communi cation module Related model for discontinuation Transition to the AnS series QnA series model AJ71QE71N B2 560mA AnS series model A1SJ71Q E71N B2 530mA Restrictions No restrictions Applicable adapter AJ71QE71N B5 400mA A1SJ71Q E71N B5 400mA No restrictions AJ71QE71N T AJ71QE71N3 T 530mA A1SJ71Q E71N3 T 530mA A1SJ71Q E71N3 T 530mA Since internal current consumption increases by combination with the A1ADP SP checking power capacity and
27. MITSUBISHI A A1S Module Conversion Adapter User s Manual A1ADP XY A1ADP SP Thank you for buying the Mitsubishi general purpose programmable controller MELSEC A Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL ATADP U JE MODEL 13JQ00 CODE IB NA 0800352 G 0909 MEE MEISEC 2006 MITSUBISHI ELECTRIC CORPORATION e SAFETY PRECAUTIONS e Always read before starting use When using this equipment thoroughly read this manual Also pay careful attention to safety and handle the module properly These precautions apply only to this equipment Refer to the user s manual of the CPU module to use for a description of the programmable controller system safety precautions These SAFTY PRECAUTIONS classify the safety precautions into two categories DANGER and CAUTION N DANGER Procedures which may lead to a dangerous condition and D cause death or serious injury if not carried out properly l NCAUTION Procedures which may lead to a dangerous condition and l cause superficial to medium injury or physical damage only if not carried out properly Depending on circumstances procedures indicated by ACAUTION may also be linked to serious results In any case it is important to follow the directions for usage Store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it
28. Q2ACPU Q4ARCPU A1NCPUP21 S3 AZNCPUP21 S3 A2NCPUP21 S4 A2ACPUP21 S3 A2ACPUP21 S4 ASACPUP21 S3 Q2ACPU S1 Q3ACPU Q4ACPU 1 The relevant modules are the CPU modules that had been discontinued at the end of September 2006 at the end of September 2008 for the models that were kept produced for more 2 years as a Spare part The CPU modules that were discontinued before the end of September 2006 and not mentioned in the above table such as the AnCPU and A3HCPU are unavailable 2 1 4 List of available remote I O stations The following table shows the link modules for MELSECNET and MELSECNET 10 remote I O station for which the A1ADP can be used AJ72LP25 AJ72LP25G AJ72LR25 AJ72BR15 AJ72QLP25 AJ72QLP25G AJ72QLR25 AJ72QBR15 1 There are restrictions on the available modules For details refer to the following manuals e Type MELSECNET MELSECNET B Data Link System Reference Manual e Type MELSECNET 10 Network System Remote I O network Reference Manual e For QnA Q4AR MELSECNET 10 Network System Reference Manual e User s manual for the relevant module 2 2 For installing the A1ADP to the A series extension base unit connected to a Q series base unit 2 2 1 System Configuration Q series main base unit If E AnS series ascos E 1 0 module C A series extension base unit i m O 0
29. SY50 120mA External wiring Changed Number of slots Changed 2 modules required Since internal current consumption increases by combination with the A1ADP XY when using the two modules checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 Program Number of occupied I O points Not changed 32 16x2 Specifications Rated output voltage Not changed Rated output current Not changed Functions Not changed A1SY60 External wiring Changed Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated output voltage Changed 48VDC not applicable Rated output current Not changed Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 40 Related model Product discontinuation model model adapter Output AY60E A1SY60E 1 External wiring Changed module 2 Number of slots Not changed 3 Program Number of occupied I O points Not changed 4 Specifications Rated output voltage Changed 48VDC not applicable Rated output current Not changed Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to 200mA A1SY60 External wiring Changed Number of slots Not
30. Y Dynamic scan output module A1S42Y O XY Dummy module A1SG62 O XY Interrupt module A18I61 O Y A1S61PN x z Power supply module A1S62PN x E A1S63P x Pulse catch module A1SP60 O XY Analog timer module A1ST60 O XY Analog input module AT DID 2 SE A1S68AD O SP A1S62DA O SP Analog output module A1S68DAI O SP A1S68DAV O SP Analog I O module AISADA 2 cle A1S66ADA O XY A1S62RD3N O SP Temperature input module A1S62RD4N O SP A1S68TD O SP A1S62TCTT S2 O SP A1S62TCRTBW S2 O SP A1S62TCRT S2 O SP A1S62TCTTBW S2 O SP A1S64TCTT S1 O SP Temperature control module A1S64TCTTBW S1 O SP A1S64TCRT S1 O SP A1S64TCRTBW S1 O SP A1S64TCTRT O SP A1S64TCTRTBW O SP A1SD61 O SP A1SD62 O SP High speed counter module A1SD62E O SP A1SD62D O SP A1SD62D S1 O SP A1SD70 x ae A1SD75M1 O SP Positioning module A1SD75M2 O SP A1SD75M3 O SP Mounting of the A1ADP field O Mountable x Not mountable Applicable adapter field XY A1ADP XY SP A1ADP SP_ Not available 19 Product Model Mounting of the A1ADP Applicable QCPU QnACPU ACPU adapter A1SD75P1 S3 O SP Positioning module A1SD75P2 S3 O SP A1SD75P3 S3 O SP Position detection module A1S62LS O SP Intelligent communication module A1SD51S O SP A1SJ71E71N B2 x O O SP A1SJ71E71N B5 x O O SP A1SJ71E71N3 T x O O SP Ethernet module A1SJ71QE71N B2 x O x SP A1SJ71QE71N B5 x
31. acity and receiving end voltage is required Refer to POINT 1 to 3 26 Product Related model for discontinuation Transition to the AnS series A series model Ans series model A1SX42 90mA Restrictions External wiring Not changed Number of slots Not changed Program Number of occupied l O points Not changed Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed Applicable adapter A1SX42 S 1 External wiring Not changed Number of slots Not changed Program Number of occupied l O points Not changed Specifications Rated input voltage Changed 12VDC not applicable Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 Alternating with A1SX40 is recommended 1 2 3 4 5 External wiring Changed Connect a 4 7kQ 1 2W or more to the external signal wire serially Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated input voltage Changed Rated input current Changed ON voltage ON current Changed
32. ae Applicable Input AX31 A1SX30 1 External wiring Changed XY module Screw size M3 gt M3 5 2 Number of slots Changed 2 modules required 3 Program Number of occupied I O points Not changed 32 16x2 4 Specifications Rated input voltage Changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed External wiring Changed XY Connector terminal block must be converted Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed 110mA 50mA AX31 S1 A1SX41 110mA 80mA AX40 A1SX40 55mA 50mA AX40 UL A1SX40 50mA External wiring Changed XY Screw size M3 gt M3 5 Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed External wiring Changed XY Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Chang
33. anged Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed Applicable adapter A1SX10 50mA A1SX10 50mA A1SX10EU External wiring Changed Screw size M3 gt M3 5 Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed External wiring Changed Screw size M3 gt M3 5 Number of slots Changed 2 modules required Program Number of occupied I O points Not changed 32 16x2 Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed External wiring Changed Number of slots Changed 2 modules required Program Number of occupied I O points Not changed 32 16x2 Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed 23 Product Related model for discontinuation Transition to the AnS series A series model AnS series model A1SX20 50mA Restrictions External wiring Changed Screw size M3
34. ation method refer to the Application standards of Extension Base Units A52B A55B or A58B in the CPU module s User s Manual 3 If the execution of 1 or 2 results in excess of rated output current of a power supply module or drop of receiving end voltage to less than 4 75VDC take the following measures 1 Review the system configuration 2 Do not use the transition models 4 As for the following nine models the current consumption is greatly increased by the transition Pay special attention to the models in 1 to 3 above 1 AY41 UL 230mA gt A1SY41 500mA 2 AY70 100mA A1SY71 400mA 3 AY81 230mA A1SY81 500mA 4 AY82EP 290mA A1SY82 930mA 5 AH42 245mA A1SH42 500mA 6 7 8 A68DAI S1 150mA gt A1S68DAI 850mA A68DAV 150mA gt A1S68DAV 650mA AJ71E71N T 400mA A1SJ71E71N3 T 690MA 1 For this model refer to A1SY40P in the transition lists from Section 8 2 to Section 8 4 For replacement with the A1SY4U refer to the manual for the specifications 22 8 2 List of Transition from the A Series to AnS Series Product Input module Related model for discontinuation Transition to the AnS series A series model Ans series model A1SX10 50mA Restrictions External wiring Changed Screw size M3 gt M3 5 Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated input voltage Not ch
35. changed Program Number of occupied I O points Changed Specifications Rated output voltage Changed 48VDC not applicable Rated output current Not changed Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to 75mA 120mA AY60S UL A1SY60 External wiring Changed Number of slots Not changed Program Number of occupied I O points Changed Specifications Rated output voltage Changed 48VDC not applicable Rated output current Not changed Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to 120mA POINT 1 to 3 41 Product Related model for discontinuation Transition to the AnS series A series model 100mA AY70 UL AnS series model A1SY71 400mA A1SY71 400mA A1SY71 Restrictions External wiring Changed Connector terminal block must be converted Number of slots Not changed Program Number of occupied I O points Changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 External wiring Changed Connector ter
36. connector or RS 422 485 terminal block A1SJ71UC24 PRF R2 R4 is available 2 For the A1SJ71UC24 PRF R2 R4 the linked operation function between the RS 232 and RS 422 is not available 3 Number of RS 232 connector pins 25 pin 9 pin AJ71C24 S1 1400mA AJ71C24 S7 1400mA None No alternative model No alternative model 53 Not used Product MODBUS module Related model for discontinuation estrictions model model adapter AJ71UC24 S2 A1SJ71UC Either RS 232 or RS 422 485 interface is 24 R2 S2 available 100mA For AnS series the linked operation between the RS 232 and RS 422 is not available RS 232 connector 25 pin 9 pin Transition to the AnS series A1SJ71UC 24 R4 S2 AJ71PB92D Since internal current consumption increases by combination with the A1ADP SP checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 A1SJ71PB No restrictions 93D 540mA 360mA Profibus AJ71PB96F A1SJ71PB 96F Since internal current consumption increases by combination with the A1ADP SP checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 560mA A1SJ71DN SP No restrictions Supersonic linear scale module A64BTL No alternative model Not used 1050mA External error check module PC fault detection module AD51FD S3 No alternative model Not used 1000mA AS91 A1SS91 No restrictions 80mA
37. consumption increases after the replacement confirm that the current consumption of the modules used does not exceed the rated output current of the power supply module used 2 When the A1ADP AnS series module is installed to an extension base unit not needing a power supply module A52B A55B or A58B in the case that the increase in 5VDC internal current consumption may cause voltage drop increases in the extension cable Therefore recalculating the receiving end voltage is required For confirmation method refer to the Application standards of Extension Base Units A52B A55B or A58B in the CPU module s User s Manual 3 The A large type series module differs from the A1ADP AnS series module in specifications For the equivalent products and specifications comparison refer to Chapter 8 and the Transition from MELSEC A QnA Large Type Series to AnS Q2AS Small Type Series Handbook L NA O8064ENG 4 AnS series 32 point I O modules and special function modules are connector type Accordingly when installing them to an A series base unit using the A1ADP its depth is deeper than when installing an A series 32 point module When using the AnS series 32 point I O modules or special function modules confirm that there is enough room Example When replacing the A series 32 point module A series 32 point terminal block module A1ADP Unit
38. ctor terminal block must be converted Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed 30 Related model for Transition to the AnS series Product discontinuation A series AnS series ans Applicable model model al adapter AX81 S2 Alternating with A1SX81 is recommended 1 External wiring Changed Connector terminal block must be converted Connect a 3 3kQ 1 2W or more or 8 2kQ 1W or more resistor serially to the external signal wire at 48VDC or 60VDC respectively Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated input voltage Changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed A1SX80 S 1 External wiring Changed Screw size M3 gt M3 5 Number of slots Changed 2 modules required Program Number of occupied I O points Changed Specifications Rated input voltage Changed 12VDC not applicable Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed 50mA 5 Functions Not changed A1SX82 S1 External wiring Changed D sub FCN connector Number of slots Not changed Program Nu
39. ed 5 Functions Not changed 25 Product Related model for discontinuation Transition to the AnS series A series model 110mA AnS series model A1SX41 80mA Restrictions External wiring Changed Connector terminal block must be converted Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed Applicable adapter A1SX41 80mA External wiring Changed Connector terminal block must be converted Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed AX41 S1 A1SX41 S1 External wiring Changed Connector terminal block must be converted Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated input voltage Changed 12VDC not applicable Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power cap
40. ed foreign matter will enter the module resulting in a failure Furthermore internal parts of the module may be flied in the short circuit test or when an overcurrent or overvoltage is accidentally applied to the external I O section 1 Installation To installation the dustproof cover into the AnS series module first insert the cover to the terminal side and then press the dustproof cover against the module as shown in the figure AnS series module i tl hi Wyar a Dustproof cover for the A1ADP XY SP 2 Removal To remove the dustproof cover from the I O module insert the tip of a flat head screwdriver into the hole as shown in the figure then pry the tab of the cover out from the hole using the screwdriver AnS series module Dustproof cover for the A1ADP XY SP 14 5 2 3 Installing removing the AnS series module 1 AnS series module installation Insert the module fixing projection of the AnS series module into a projection mounting hole for fixing A1S module on the A1ADP AnS series module Install the AnS series module to the A1ADP by pushing it in the direction of an arrow Tighten the module mounting screw after confirming that the CA Module Projection mounting fixin module is securely installed to es 19 module Completed A1ADP Module mounting screw AnS series module LA
41. f slots Not changed Program Number of occupied I O points Changed 32 points occupied Specifications Rated output voltage Changed 12VDC not applicable Rated output current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 External wiring Not changed Number of slots Not changed Program Number of occupied I O points Changed 32 points occupied Specifications Rated input voltage Changed 12VDC not applicable Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed 44 Applicable adapter Related model for Transition to the AnS series Product discontinuation A series AnS series Restrictions Applicable model model adapter Dynamic A1S42X 1 External wiring Changed scan I O 80mA 2 Number of slots Changed module Since internal current consumption increases by combination with the A1S42Y A1ADP XY when using the two modules 180mA checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 Program Number of occupied I O points Changed 128 points occupied 64x2 Specifications Rated output voltage Changed 12VDC not applicable Rated
42. g power capacity and receiving end voltage is required Refer to POINT 1 to 3 Applicable adapter AY11 UL A1SY10 External wiring Changed Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated output voltage Not changed Rated output current Not changed However contact life span is reduced to half Functions Changed No varistor Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 34 Related model for Transition to the AnS series Product discontinuation A series AnS series Restricti Applicable estrictions model model adapter Output AY13 A1SY10 External wiring Changed module Number of slots Changed 2 modules required Since internal current consumption increases by combination with the A1ADP XY when using the two modules checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 Program Number of occupied I O points Not changed 32 16x2 Specifications Rated output voltage Not changed Rated output current Not changed However contact life span is reduced to half 120mA Functions Not changed A1SY10 External wiring Changed Number of slots Changed 2 modules required Since internal current consumption increases by combination with the A1ADP XY when using the two modules
43. hanged Input resistance Changed Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 28 Product Input module Related model for discontinuation Transition to the AnS series A series model AX71 110mA AnS series model A1SX71 75mA A Restrictions External wiring Changed Connector terminal block must be converted Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed Applicable adapter XY AX80 55mA A1SX80 50mA A External wiring Changed Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed XY AX80 UL 55mA AX80E 55mA A1SX80 50mA A1SX80 S1 50mA A A 2 3 4 5 External wiring Changed Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated input voltage Not changed Rated i
44. ics and increased current consumption Function specifications Not changed Since internal current consumption increases by combination with the A1ADP SP checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 External wiring Changed Terminal block is different Number of slots Not changed Program I O signals and buffer memory address are changed Performance specifications change Output current range I O characteristics and increased current consumption Function specifications Not changed Since internal current consumption increases by combination with the A1ADP SP checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 48 Applicable adapter SP Related model for Transition to the AnS series Product discontinuation A series Ans series Restrictions Applicable model model adapter A616TD None Using the A1S68TD is recommended Not used 1 External wiring Changed Terminal block is different 2 Number of slots Changed 2 modules required 3 Program I O signals and buffer memory address are changed 4 Performance specifications change 8CH module input temperature range and conversion accuracy 5 Function specifications The relation between the conversion disable channel and the conversion time is 1000mA changed A68RD3N None Using the A1S62RD3N is recommended Not used 1 External wiring Changed Terminal
45. it installing side 104 08 O oO Name A screw for installing the A1ADP to a base people EnOUntnG Screw unit Make sure to tighten the screw A screw hole for fixing the A1ADP to AnS 2 Module mounting screw hole series module for M4 screw Make sure to tighten the screw ve eee A connector for connecting the A1ADP to nS series module Projection mounting hole for A hole for attaching the module fixing fixing A1S module projection on AnS series module A hook for fixing it to the module fixing hole on a base unit A connector for connecting the A1ADP to a base unit A seal such as the product name is described A projection for fixing it to the module fixing hole on a base unit 5 Adapter fixing hook Base connector 7 Rating plate Adapter fixing projection 10 5 LOADING AND INSTALLATION 5 1 Precautions when Handling The following is an explanation of handling precautions of the A1ADP 1 Since the adapter case is made of plastic do not drop it or subject it to mechanical impact to it 2 Execute tightening of installation screws within the range indicated below Tightening torque range Module installation screw of AnS series M4 screw 78 to 118Necm Adapter mounting screw M4 screw 78 to 118Necm 3 To correctly install the adapter module to the base unit insert the adapter fixing projections provided at the bottom of the module in the module mounting holes i
46. ltage Directives installing a noise filter power supply line filter as the following is required a When using the A1ADP XY with an AnS series output module attach any of the following noise filters power supply line filters to reduce conductive noise of 24VDC external supply power cable Notse fiter mode ZHC2203 11 ZHC2206 11 ZHC2210 11 MBS4830 Manufacturer TDK DENSEI LAMBDA Rated current 3A GA 10A 30A Rated voltage 250V 48V A 6 b Referring to the following attach a noise filter power supply line filter to the 24VDC external supply power cable connected to the AnS series output module AnS output module side OUT OUT 24VDC 24GDC A1ADP XY On a control panel Ans output module Noise filter power supply line filter Output signal cable 24VDC power supply side 24VDC power supply c The following describes the precautions for attaching a noise filter 1 Do not bundle the wires on the input side and output side of the noise filter When bundled the input side noise will be induced into the output side wires from which the noise was filtered 24VDC power supply side 24VDC power supply side Induction Induction Filter Filter AnS output module side AnS output module side 1 The noise will be included when the input 2 Separate and lay the input and output wires and
47. mber of occupied I O points Not changed Specifications Rated input voltage Changed 12VDC not applicable Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 31 Product Related model for discontinuation Transition to the AnS series A series model AnS series model A1SY10 120mA Restrictions External wiring Changed Number of slots Not changed Program Number of occupied l O points Not changed Specifications Rated output voltage Not changed Rated output current Not changed However contact life span is reduced to half Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 Applicable adapter 115mA A1SY18A 240mA External wiring Changed Number of slots Changed 2 modules required Program Number of occupied I O points Changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end
48. minal block must be converted Number of slots Not changed Program Number of occupied I O points Changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 External wiring Changed Connector terminal block must be converted Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 42 Applicable adapter Related model Product discontinuation model model adapter Output AY72 A1SY71 1 External wiring Not changed module 2 Number of slots Changed 2 modules required 3 Program Number of occupied I O points Not changed 64 32x2 4 Specifications Rated output voltage Not changed Rated output current Not changed 5 Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to 400mA A1SY80 External wiring Changed Number of slots Not changed Program Number of occupied I
49. n the base unit And then secure the module by tightening the adapter mounting screw To remove the module remove the adapter mounting screw first And then pull out the module so that the adapter fixing projections are removed from the holes in the base unit 5 2 Installation Removal Procedures of the A1ADP AnS Series Module This section describes the procedures for installing removing the A1ADP to from a base unit and AnS series module 1 Installation procedure Install the A1ADP to a Refer to Section 5 2 1 1 base unit Attach a dustproof cover to J Refer to Section 5 2 2 1 the AnS series module to be installed to the A1ADP Install the AnS series Refer to Section 5 2 3 1 module to the A1ADP Completed POINT Note when installing the AnS series module before tightening an adapter mounting screw of the A1ADP the tightening cannot be done 2 Removal procedure Refer to Section 5 2 3 2 Remove the AnS series module from the A1ADP Remove the A1ADP from Refer to Section 5 2 1 2 the base unit Completed 11 5 2 1 Installing removing the A1ADP 1 A1ADP installation Adapter fixing hook Insert the two adapter fixing Module fixing hole A projections into the module fixing hole B in the base unit Base unit Load the adapter into the base unit by pushing it in the direction of arrow Module connector
50. nitor station function not available 350mA A1SJ71PT 32 S3 1 Monitor station function not available SP 2 Since internal current consumption increases by combination with the A1ADP SP checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 None x Changing the system from Not used recommended A1SJ51T64 i No restrictions 115mA 52 Product Related model for discontinuation Transition to the AnS series A series model AJ71J92 S3 500mA AnS series model A1SJ71J92 S3 400mA Restrictions No restrictions Applicable adapter Terminal interface module AJ71B62 S3 170mA AJ71C21 S1 900mA A1SJ71B6 2 S3 80mA None No restrictions No alternative model Not used Multidrop link module AJ71C22 S1 1400mA A1SJ71UC 24 R4 The following functions are different 1 Buffer memory Work area 61h to O7FF_ 71h to ODFFh 2 LED For slave station I O monitor display AvailableNone 3 Setting switch Baud rate setting Fixed to 38400bps_ Settable to 19200 38400 Master local Fixed to master_ Settable 4 Terminal block screw M4_ M3 5 5 Terminal resistor Built in_ externally connected SP Host controller high speed link AJ71C23 S3 1500mA No alternative model Not used Computer link module AJ71UC24 300mA A1SJ71UC 24 PRF 100mA A1SJ71UC 24 R2 100mA A1SJ71UC 24 R4 100mA 1 Either the RS 232
51. nput current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed External wiring Changed Screw size M3 M3 5 Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated input voltage Changed 12VDC not applicable Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions Not changed 29 XY XY Related model Product discontinuation model model adapter Input AX81 A1SX81 1 External wiring Changed module Connector terminal block must be converted 2 Number of slots Not changed 3 Program Number of occupied I O points Not changed 4 Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed 110mA 5 Functions Not changed AX81B Alternating with A1SX81 is recommended Not used 1 External wiring Changed Connector terminal block must be converted 2 Number of slots Not changed 3 Program Number of occupied I O points Changed 4 Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed Functions The wire breakage detection function not 55mA provided AX81 S1 A1SX81 External wiring Changed Conne
52. output wires are bundled 2 Earth the noise filter earthing terminal to the control cabinet with the shortest wire possible approx 10cm 3 94 in 1 OVERVIEW 1 1 Overview This manual describes specifications system equipment part names loading and installation of the A A1S module conversion adapters of the A1ADP XY type and A1ADP SP type The A1ADP is an adapter module used to install the AnS series I O modules and special function modules to the base unit for A QnA large type series aa AnS series module A1S conversion adapter 1 For details of the system configuration that enables the installing the A1ADP to A series base units refer to Chapter 2 ATADPEXY si tasas For the AnS series I O modules AIADP2SPic cccieti estes For the AnS series special function modules POINT When modules are installed in either of the following combinations the operation is not guaranteed e Combination of the A1ADP XY with the AnS series special function modules Combination of the A1ADP SP with the AnS series I O modules However for the following models the combination of the module type configured in the I O assignment setting and the A1ADP model that can be combined differs Pay attention when selecting the A1ADP A1SI61 Special module A1ADP XY A1SJ51T64 Output module A1ADP SP A1SS91 Output module A1ADP SP 1 2 Supplied Parts The parts enclosed with the
53. pied l O points Not changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Changed Fuse not replaceable Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 External wiring Changed Number of slots Changed 2 modules required Since internal current consumption increases by combination with the A1ADP XY when using the two modules checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 Program Number of occupied I O points Not changed 32 16x2 Specifications Rated output voltage Not changed Rated output current Not changed Functions Not changed 39 Applicable adapter Related model for discontinuation Transition to the AnS series A series model AY51 S1 AnS series model A1SY50 120mA Restrictions External wiring Changed Number of slots Changed 2 modules required Since internal current consumption increases by combination with the A1ADP XY when using the two modules checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 Program Number of occupied I O points Not changed 32 16x2 Specifications Rated output voltage Not changed Rated output current Not changed Functions Changed Fuse not replaceable Applicable adapter A1
54. pters touch a grounded metal object to discharge the static electricity from the human body Failure to do so may cause a failure or malfunctions of the installed module DISPOSAL PRECAUTIONS NCAUTION e When disposing of this product treat it as industrial waste Revisions The manual number is noted at the lower right of the top cover Print Date anual Number Jun 2006 IB NA 0800352 A First printing May 2007 BNA 0600362 Section 2 3 Chapter 7 Section 8 2 Oct 2007 IB NA 0800352 C Chapter 7 Section 8 2 Jul 2008 IB NA 0800352 D Chapter 7 Nov 2008 IB NA 0800352 E es 2 1 2 2 8 2 Feb 2009 IB NA 0800352 F gorrection 1 1 1 3 2 1 3 2 3 Chapter 7 SECON 8 1 8 2 Section 2 1 4 Sep 2009 IB NA 0800352 G Chapter 7 This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual 2006 MITSUBISHI ELECTRIC CORPORATION A 4 CONTENTS DEON ERR VW he a A de e A a ae oh a 1 a MS A A aos et 1 VAS SA ti cd 2 1 3 Related Parts Sold Separately cooooonccnccccconocononoconoronnncnnnnnnnonnnnnnos 2 2 SYSTEM CONFIGURATION erected are oo ero nk co thot eh Sta 3 2 1 For installing the A1ADP to an A QnA large type series main ba
55. receiving end voltage is required Refer to No restrictions AJ71QC24N 400mA A1SJ71Q C24N 350mA RS 232 connector 25 pin gt 9 pin AJ71QC24N R2 300mA A1SJ71Q C24N R2 300mA RS 232 connector 25 pin gt 9 pin AJ71QC24N R4 600mA AJ61QBT 11 450mA A1SJ71Q C24N 350mA For Q2AS series use A1SJ71QC24N and connect the RS232 422 converter to 1ch No restrictions 55 8 4 List of Transition from the Q4AR Series to AnS Series Product Ethernet module Serial communi cation module Related model for discontinuation Transition to the AnS series Q4AR series model AJ71QE71N B2 560mA AJ71QE71N B5 400mA AJ71QE71N T 400mA AJ71QE71N3 T 530mA AJ71QC24N 400mA AJ71QC24N R2 300mA AJ71QC24N R4 600mA AnS series model A1SJ71QE 71N B2 530mA Restrictions No restrictions Applicable adapter A1SJ71QE 71N B5 400mA No restrictions A1SJ71QE 71N3 T 530mA Since internal current consumption increases by combination with the A1ADP SP checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 A1SJ71QE 71N3 T 530mA No restrictions A1SJ71QC 24N 350mA RS 232 connector 25 pin gt 9 pin A1SJ71QC 24N R2 300mA A1SJ71QC 24N 350mA RS 232 connector 25 pin gt 9 pin For Q2AS series use A1SJ71QC24N and connect the RS232 422 converter to 1ch 56
56. ripheral device connection connector 700MA 700MA is different AD75M2 A1SD75M2 O No restrictions SP The A1SD75 C01HA cable is required since the peripheral device connection connector 700MA 700MA is different AD75M3 A1SD75M3 No restrictions SP The A1SD75 C01HA cable is required since the peripheral device connection connector 700MA 700mA is different AD75P1 S3 A1SD75P1 No restrictions SP S3 The A1SD75 CO1HA cable is required since the peripheral device connection connector 700mA 700MA is different AD75P2 S3 A1SD75P2 No restrictions SP S3 The A1SD75 C01HA cable is required since the peripheral device connection connector 700mMA 700mMA is different AD75P3 S3 A1SD75P3 No restrictions SP S3 The A1SD75 C01HA cable is required since the peripheral device connection connector 700mA 700MA is different 1 As for specification A 50 Product Position detection module Related model for discontinuation Transition to the AnS series A series model A61LS 800mA A62LS S5 1500mA A63LS 1350mA Intelligent communi cation Ethernet module AD51H S3 1000mA AD51 S3 1300mA AJ71E71N B2 670mA AJ71E71N B5 550mA AnS series model None None None A1SD51S 400mA A1SD51S 400mA A1SJ71E 71N B2 660mA A1SJ71E 71N B5 570mA Restrictions No alternative model No alternative model No alternative model The A1SD518S is different from the AD51H S3 in the following
57. se unit or extension Dase e teeta 3 2 1 1 System CONTIGUOS 3 2152 Available Base Units LIS lt a ear AEEA decks EEEE 4 2 1 3 Available CPU modules liSt ooccocccoccnncnncnncinanoncnncnnanoninaninanonos 4 2 1 4 List of available remote I O Stations oocconcconcccccccncnnncccnaconanonanonan 5 2 2 For installing the A1ADP to the A series extension base unit connected to a Q seres Dase UIE ses cool cunas celosos esa deca ad a ul e al e a e 6 2 2 1 System COMNGUIAION sinc eds e aS 6 2 2 2 Available Base Units IS oi o 6 223 Available CRU Mods ed dde 6 2 3 PPECAUllONS tor WSC dai dida decai 7 SO PECIEICATION Sa e 9 3 1 Performance Specifications ance cc freed ita 9 A PARTO NAMES cin 10 5 LOADING AND INSTALLATION ooocccncccnccnnccnnccnnccnnnnonononononnnonnnnnnnnnnanonanonans 11 5 1 Precautions when Hand INQ oooccccooccnnconcccccnnccnnnnoncncnnnccnnnnnncnnnnnccnnnnnns 11 5 2 Installation Removal Procedures of the A1ADP AnS Series Module 11 5 2 1 Installing removing the AYADP ccccccccsseeeeeececeeeseeeeeseaneeeeeeees 12 5 2 2 Installing removing the dustproof COVeT oooccccccconocccnnccconoconnnnnnnnannnnns 14 5 2 3 Installing removing the AnS series module oooooocccccccoocccnnccnnnonono 15 6 EXTERNAL DIMENSIONS td ee ea ds 17 7 COMPATIBLE MODELS LIST orcos rd dd 18 8 REPLACEABLE MODULES ST iio 21 8 1 How to See TAG lists a ceed taarssaace tuandopaienatenedacadaasvesnceedasac
58. ses 21 8 2 List of Transition from the A Series to AnS Series cccccceceeecee nese ees 23 8 3 List of Transition from the QnA Series to AnS Series ccccceeseeee ees 55 8 4 List of Transition from the Q4AR Series to AnS Series cccceee 56 A 5 GENERIC TERMS AND ABBREVIATIONS Unless otherwise specified this manual uses the following generic terms and abbreviations to explain the A A1S module conversion adapter Generic term abbreviation Description Abbreviation for the A A1S module conversion PAD EA adapter of the A1ADP XY type Abbreviation for the A A1S module conversion adapter of the A1ADP SP type A1ADP Generic term for the A1ADP XY and A1ADP SP A1ADP AnS series Abbreviation when the AnS series I O module or module special function module is installed to the A1ADP A1ADP SP Conformation to the EMC Directive and Low Voltage Instruction 1 For programmable controller system When complying with EMC Directives and Low Voltage Directives by assembling a Mitsubishi programmable controller compatible with EMC Directive and Low Voltage Directives into the user product refer to EMC Directives and Low Voltage Directives in the User s Manual for the CPU module being used The CE mark indicating compliance with the EMC and Low Voltage Directives is printed on the rating plate of the programmable controller 2 For the product For the compliance of this product with the EMC and Low Vo
59. specifications AD51H S3 gt A1SD51S 1 Number of tasks 8 2 2 Memory 300 60kbytes 3 Parallel Available None 4 RS 232 connector 25 pin 9 pin 5 Number of slots 2 gt 1 One slot will be an empty slot 6 Memory card I F 2 0 File creation is disabled 7 LED display not provided 8 Program record medium Memory card EPROM built in EEPROM Replace the BASIC program with a program for A1SD51S No restrictions Since internal current consumption increases by combination with the A1ADP SP checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 Applicable adapter Not used Not used Not used SP AJ71E71N T AJ71E71N3 T 690mA A1SJ71E 71N3 T 690mA A1SJ71E 71N3 T 690mA Since internal current consumption increases by combination with the A1ADP SP checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 No restrictions 51 Related model for Product discontinuation Transition to the AnS series A series AnS series Restrictions Applicable model model adapter SP AJ71AT21B 720mA MELSEC AJ71AP21 NET data link module 500mA AJ71AR21 900mA CC Link master local module AJ61BT 11 MELSEC AJ71PT32 S3 NET MINI 350mA AJ71T32 S3 AJ71T32 S4 300mA AJ51T64 115mA A1SJ71AT No restrictions A1SJ71AR No restrictions SP 21 SP No restrictions A1SJ71PT 32 S3 Mo
60. untable only when the multidrop link function is used 20 8 REPLACEABLE MODULES LIST The following lists the A QnA large type series modules that can be replaced by the A1ADP AnS series module 8 1 How to See the List Related model for Transition to the AnS series Product discontinuation A series AnS series Restricti Applicable estrictions model model adapter Ethernet AJ71E71N B2 A1SJ71E71N No restrictions module B2 670mA 660mA Input AX50 S1 None Alternating with A1SX40 is recommended module 1 External wiring Changed Connect a 4 7kQ 1 2W or more to the external signal wire serially 2 Number of slots Not changed 3 Program Number of occupied I O points Not changed 4 Specifications Rated input voltage Not changed Rated input current Changed ON voltage ON current Changed OFF voltage OFF current Changed Input resistance Changed 5 Functions Not changed i ii iti iv v i Classifies the transition list by a product ii Indicates each module name of the A series and its 5VDC internal current consumption iii Indicates each module name of the AnS series and its 5VDC internal current consumption 5VDC internal current consumption for the A1ADP AnS series module is calculated by adding the 5VDC internal current consumption for the A1ADP to this value For the A1ADP XY The value above 3 4mA For the A1ADP SP The value above OmA 21 iv Indicates
61. ut voltage Not changed Rated output current Not changed Response time Changed from 0 3ms to 1ms or less Functions Not changed External wiring Not changed Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Changed The short protection function equivalent to fuse included AY42 S4 A1SY42P 1 2 3 4 5 External wiring Changed External supply power is required Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Not changed 38 Product Related model for discontinuation Transition to the AnS series A series model 115mA AY50 UL AnS series model A1SY50 120mA A1SY50 120mA A1SY50 4 5 Restrictions External wiring Changed Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Changed Fuse not replaceable Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 External wiring Changed Number of slots Not changed Program Number of occu
62. voltage is required Refer to POINT 1 to 3 AY10A UL A1SY18A External wiring Changed Number of slots Changed 2 modules required Program Number of occupied I O points Changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Not changed Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 32 Related model Product discontinuation model model adapier Output AY11 A1SY10 1 External wiring Changed module 2 Number of slots Not changed 3 Program Number of occupied I O points Not changed 4 Specifications Rated output voltage Not changed Rated output current Not changed However contact life span is reduced to half Functions Changed No varistor relay not replaceable Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to 120mA A1SY18A External wiring Changed Number of slots Changed 2 modules required Program Number of occupied I O points Changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Changed No varistor Since internal current consumption increases by combination with the A1ADP XY checking power capacity and receiving end voltage is required Refer to 11
63. wo modules checking power capacity and receiving end voltage is required Refer to POINT 1 to 3 Program Number of occupied I O points Changed Specifications Rated output voltage Not changed Rated output current Not changed Response Slow Functions Not changed External wiring Changed Connector terminal block must be converted Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Not changed 37 Related model for discontinuation Transition to the AnS series A series model AY41 UL 340mA AnS series model A1SY41P 141mA A1SY42P 170mA Restrictions External wiring Changed Connector terminal block must be converted Number of slots Not changed Program Number of occupied l O points Not changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Not changed External wiring Not changed Number of slots Not changed Program Number of occupied l O points Not changed Specifications Rated output voltage Not changed Rated output current Not changed Functions Not changed Applicable adapter AY42 S1 290mA AY42 S3 290mA A1SY42P 170mA A1SY42P 170mA External wiring Not changed Number of slots Not changed Program Number of occupied I O points Not changed Specifications Rated outp
64. ws within the specified torque range If the screw is too loose it may cause a short circuit fire or malfunctions If too tight it may damage the screw and or the module resulting in a short circuit or malfunctions e Carefully prevent foreign matter such as dust or wire chips from entering the module Failure to do so may cause a fire failure or malfunctions STARTING AND MAINTENANCE PRECAUTIONS lt DANGER O Be sure to shut off all phases of the external supply power used by the system before cleaning or retightening the terminal screws module mounting screw or adapter mounting screw Failure to do so may result in an electric shock If they are too loose it may cause a short circuit or malfunctions If too tight it may cause damage to the screws and or module resulting in a drop of the adapter and installed module short circuit or malfunctions CAUTION e Do not disassemble or modify each of adapters Doing so may cause a failure malfunctions personal injuries and or a fire e When using a wireless communication device such as a mobile phone keep a distance of 25cm 9 84inch or more from the programmable controller in all directions Failure to do so may cause malfunctions O Be sure to shut off all phases of the external supply power used by the system before installing or removing the adapter Failure to do so may result in a failure or malfunctions of the adapter and installed module e Before handling ada