Home
Product Data Sheet and Manual TS8015 HP471055U015
Contents
1. Bulletin HP471055U015 Issue 1 0 Drawing No LP0878X Effective 10 11 MODEL TS8015 GRAPHIC COLOR LCD OPERATOR INTERFACE TERMINAL WITH TFT XGA DISPLAY AND TOUCHSCREEN GENERAL DESCRIPTION The TS8015 Operator Interface combines powerful features normally found only in PC based HMIs with the reliability of a dedicated operating system It is built around a high performance core with integrated features allowing it to provide SCADA like functionality at a fraction of the cost The TS8015 is able to act as a multiple protocol converter using four high speed RS232 422 485 communications ports and an Ethernet 10 100 Base TX port The Ethernet port supports up to four protocols simultaneously allowing dissimilar Ethernet based products to communicate with one another The TS8015 s USB port allows fast downloads of configuration files and access to trending and data logging A CompactFlash socket is provided so that standard ComplactFlash cards can be used to collect your trending and data logging information as well as to store configuration files The built in web server allows processes to be controlled remotely The TS8015 s large high resolution display allows users to easily view and enter information Data can be manipulated through the touchscreen and or the 10 button keypad SAFETY SUMMARY All safety related regulations local codes and instructions that appear in the manual or on equipment must be observed to ensure perso
2. These CCFL tubes have a limited lifetime Backlight lifetime is based upon the amount of time the display is turned on at full intensity Turning the backlight off when the display is not in use can extend the lifetime of your backlight This can be accomplished through the DSI8000 software when configuring your unit KEYPAD The TS8015 keypad consists of ten keys that can be used for on screen menus TOUCHSCREEN This operator interface utilizes a resistive analog touchscreen for user input The unit will only produce an audible tone beep when a touch on an active touchscreen cell is sensed The touchscreen is fully functional as soon as the operator interface is initialized and can be operated with gloved hands TROUBLESHOOTING YOUR TS8015 If for any reason you have trouble operating connecting or simply have questions concerning your new TS8015 contact Parker SSD Drives technical support For contact information refer to the back page of this bulletin for phone and fax numbers EMAIL info us ssd parker com Web Site http www ssddrives com usa FRONT PANEL LEDS There are three front panel LEDs Shown below is the default status of the LEDs LED INDICATION GREEN TOP LABELED PWR FLASHING Unit is in the boot loader no valid configuration is loaded STEADY Unit is powered and running an application YELLOW MIDDLE OFF No CompactFlash card is present STEADY Valid CompactFlash card pr
3. 4 Read Power Supply Requirements in the section Installing and Powering the TS8015 for additional power supply information BATTERY Lithium coin cell Typical lifetime of 10 years LCD DISPLAY SIZE 15 inch TYPE TFT COLORS 32K PIXELS BRIGHTNESS BACKLIGHT 1024 X 768 600 cd m2 50 000 HR TYP Lifetime at room temperature Refer to Display in Software Unit Operation 4 3 10 KEY KEYPAD for on screen menus TOUCHSCREEN Resistive analog 6 MEMORY On Board User Memory 64 Mbyte of non volatile Flash memory Memory Card CompactFlash Type II slot for Type I and Type H CompactFlash cards COMMUNICATIONS USB Device Port Adheres to USB 2 0 Specification supporting high speed and full speed via Type B connection POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON HAZARDOUS USB PORT IS FOR SYSTEM SET UP AND DIAGNOSTICS i WARNING DO NOT CONNECT OR DISCONNECT CABLES WHILE AND IS NOT INTENDED FOR PERMANENT CONNECTION USB Host Ports Comply with Universal Serial Bus Specification Rev 2 0 Support data transfers at full speed Hardware over current protected 0 5 A max per port Serial Ports Format and Baud Rates for each port are individually software programmable up to 115 200 baud PGM Port RS232 port via RJ12 COMMS Ports RS422 485 port via RJ45 and RS232 port via RJ12 DH485 TXEN Transmit enable open collector Voy 15 VDC Vor 0 5 V 25 mA
4. established at either 10 BASE T or 100 BASE TX The TS8015 unit s RJ45 jack is wired as a NIC Network Interface Card For example when wiring to a hub or switch use a straight through cable but when connecting to another NIC use a crossover cable The Ethernet connector contains two LEDs A yellow LED in the upper right and a bi color green amber LED in the upper left The LEDs represent the following statuses YELLOW solid Link established YELLOW flashing Data being transferred GREEN 10 BASE T Communications AMBER 100 BASE TX Communications On the rear of each unit is a unique 12 digit MAC address and a block for marking the unit with an IP address Refer to the DSI8000 manual for additional information on Ethernet communications WIRING THE TS8015 TS8015 PORT PIN OUTS PROTECTIVE EARTH GROUND L CTS PIN 1 TxA PIN 8 TXB PIN 1 RxB RxA TxA TxA PIN 8 TxA TxB PIN 1 RTS PIN 6 Tx COMM COMM Rx 1 COMMON 2 24V 20 Rx Ei Rx Ei x POWER CONNECTOR RS232 PORTS The TS8015 has two isolated RS232 ports The port marked RS232 PORT A PGM PORT may be used for programming as well as communications while the port marked RS232 PORT B may only be used for communications Both ports can be used for either master or slave protocols RS232 CONNECTIONS RTS PIN6 Tx CTS PIN 1 COMM COMM Rx ETHERNET
5. 2023 WARNING EXPLOSION HAZARD BATTERIES MUST ONLY BE CHANGED IN AN AREA KNOWN TO BE NON HAZARDOUS CAUTION RISK OF ELECTRIC SHOCK The inverter board attached to the mounting plate supplies the high voltage to operate the backlight Touching the inverter board may result in injury to personnel COVER PLATE FUTURE EXPANSION OPTIONAL FEATURES AND ACCESSORIES COMPACTFLASH SOCKET CompactFlash socket is a Type II socket that can accept either Type I or II cards Use cards with a minimum of 4Mbytes with the TS8015 s CompactFlash socket Cards are available at most computer and office supply retailers CompactFlash can be used for configuration transfers larger configurations data logging and trending Information stored on a CompactFlash card by a TS8015 can be read by a card reader attached to a PC This information is stored in IBM Windows PC compatible FAT16 file format CompactFlash R Insert Face Up Note Do not remove or insert the CompactFlash card while power is applied Refer to Front Panel LEDs OPTIONAL COMMUNICATION CARD Parker SSD Drives offers optional communication cards for fieldbus communications These communication cards will allow your TS8015 to communicate with many of the popular fieldbus protocols Parker SSD Drives is also offering a communications card for additional RS232 and RS422 485 communications NOTE For reliable operation of this and othe
6. 32 PORT B PORTB gi ISOLATED ISOLATED AUXILIARY ETHERNET ETHERNET il CONNECTING TO EARTH GROUND The protective conductor terminal is bonded to conductive N amp parts of the equipment for safety purposes and must be connected to an external protective earthing system Each TS8015 has a chassis ground terminal on the back of the unit Your unit should be connected to earth ground protective earth The chassis ground is not connected to signal common of the unit Maintaining isolation between earth ground and signal common is not required to operate your unit But other equipment connected to this unit may require isolation between signal common and earth ground 70 maintain isolation between signal common and earth ground care must be taken when connections are made to the unit For example a power supply with isolation between its signal common and earth ground must be used Also plugging in a USB cable may connect signal common and earth ground 1 USB s shield may be connected to earth ground at the host USB s shield in turn may also be connected to signal common POWER SUPPLY REQUIREMENTS The TS8015 requires a 24 VDC power supply Your unit may draw considerably less than the maximum rated power depending upon the options being used As additional features are used your unit will draw increasing amounts of power Items that could cause increases in current are additio
7. A 4 kV contact discharge 8 kV air discharge Electromagnetic RF fields EN 61000 4 3 Criterion A 10 V m 80 MHz to 1 GHz 3 V m 1 4 GHz to 2 GHz 1 V m 2 GHz to 2 7 GHz Fast transients burst EN 61000 4 4 Criterion A power 2kV VO signal 1kV Surge EN 61000 4 5 Criterion B power 1kVLtoL 2kVLtoG signal 1 kV RF conducted interference EN 61000 4 6 Criterion A 3 Vrms Power freq magnetic field EN 61000 4 8 Criterion A 30 A m AC power EN 61000 4 11 N A Voltage dip 0 during 1 cycle 40 during 10 12 cycle 70 during 25 30 cycle Short interruptions 0 during 250 300 cycles Emissions Emissions Note 1 Criterion A Normal operation within specified limits 2 Criterion B Temporary loss of performance from which the unit self recovers 0 CONNECTIONS Compression cage clamp terminal block Wire Gage 12 22 AWG copper wire Torque 5 7 inch pounds 56 79 N cm 1 CONSTRUCTION Steel rear metal enclosure with NEMA 4X IP66 aluminum front plate for indoor use only when correctly fitted with the gasket provided Installation Category II Pollution Degree 2 2 MOUNTING REQUIREMENTS Maximum panel thickness is 0 25 6 3 mm For NEMA 4X IP66 sealing a steel panel with a minimum thickness of 0 125 3 17 mm is recommended Maximum Mounting Stud Torque 17 inch pounds 1 92 N m 3 WEIGHT 11 41 Ibs 5 17 Kg EN 55011 Class A 14 59 370 6 PROTECTIVE EARTH GROUND INSTALLING AND POWERING THE TS8015 MO
8. AUXILIARY NIC ETHERNET NIC STATUS STATUS RS232 PORTA PGM PORT RS422 485 COMMS PORT The TS8015 has two isolated RS422 485 ports These ports can be configured to act as either RS422 or RS485 RS485 2 WIRE CONNECTIONS RS422 485 4 WIRE CONNECTIONS TxEN OC TxEN OC GND Note All Parker SSD Drives devices connect A to A and B to B Examples of RS485 2 Wire Connections TS to Parker SSD Drives RJ11 Connections TS RJ45 SSD RJ11 2 3 5 4 DH485 Connections The TS8015 s RS422 485 COMMS port can also be used for Allen Bradley DH485 communications WARNING DO NOT use a standard DH485 cable to connect this port to Allen Bradley equipment A cable and wiring diagram are available from Parker SSD Drives TS to AB SLC 500 COMM TxEN SHIELD COMM 24V SOFTWARE UNIT OPERATION DSI8000 SOFTWARE DSI8000 software is available as a free download from Parker SSD Drives website The latest version of the software is always available from the website and updating your copy is free DISPLAY This operator interface uses a liquid crystal display LCD for displaying text and graphics The display utilizes a cold cathode fluorescent tube CCFL for lighting the display The CCFL tubes can be dimmed for low light conditions
9. NT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS INSTALLING AN OPTION CARD WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED AND THE AREA IS KNOWN TO BE NON HAZARDOUS Each option card comes with a cable for communications and three screws for attaching the option card to the TS s main board To install the option card remove all power and I O communications cables from the unit and remove the rear cover Connect the cable from the option card to the connector on the main board Be sure both ends of the cable are firmly seated into their appropriate connector housings Use the three screws provided to mount the option card to the main board as shown in Figure 1 Carefully replace the rear cover by reversing the instructions for removing the rear cover Figure 1 TYPICAL EXPANSION CARD INSTALLATION COMMUNICATING WITH THE TS8015 CONFIGURING A TS8015 The TS8015 is configured using DSI8000 software DSI8000 is available as a free download from Parker SSD Drives website Updates to DSI8000 for new features and drivers are posted on the website as they become available By configuring the TS8015 using the latest version of DS18000 you are assured that your unit has the most up to date feature set DS18000 software can configure the TS8015 through the RS232 PGM port USB port Ethernet port or CompactFlash The USB port is c
10. Terminal block for connecting power ORDERING INFORMATION DESCRIPTION TS8015 00 00 8000 CB 00 00 8000 PB 00 00 8000 DN 00 00 8000 FA 00 00 15 TFT XGA Display Operator Interface indoor USB Host CANopen Option Card Profibus DP Option Card DeviceNet Option Card FireWire Option Card The protective conductor terminal is bonded to conductive parts of the equipment for safety purposes and must be connected to an external protective earthing system A A WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS DIVISION 2 CompactFlash is a registered trademark of CompactFlash Association SPECIFICATIONS Al 2 3 POWER REQUIREMENTS Must use NEC Class 2 or Limited Power Source LPS rated power supply Power connection via removable three position terminal block Supply Voltage 24 VDC 20 Typical Power 38 W Maximum Power 46 W Notes 1 Typical power with 24 VDC RS232 485 communications Ethernet communications CompactFlash card installed flash drive installed in one USB Host port and display at full brightness 2 Maximum power is consumed when all features and comm ports are used at the same time Refer to Power Supply Requirements under Installing and Powering the TS8015 3 The TS8015 5 circuit common is not connected to the enclosure of the unit See Connecting to Earth Ground in the section Installing and Powering the TS8015
11. UNTING INSTRUCTIONS This operator interface is designed for through panel mounting A panel cut out diagram and a template are provided Care should be taken to remove any loose material from the mounting cut out to prevent that material from falling into the operator interface during installation A gasket is provided to enable sealing to NEMA 4X IP66 specification Install the 22 kep nuts provided and tighten evenly for uniform gasket compression Note Tightening the kep nuts beyond a maximum of 17 inch pounds 1 92 N m may cause damage to the front panel u 15 425 391 8 10 283 261 2 5 142 130 6 22X 9 188 m VA 24 8 pH E E 7 455 i 189 4 W720 fo ll 2 485 297 7 i 63 1 i i 12 425 315 6 i il i 1 H CS a 5 t ea 14 720 373 9 ________w All tolerances 0 010 0 25 mm ALL NONINCENDIVE CIRCUITS MUST BE WIRED USING DIVISION 2 WIRING METHODS AS SPECIFIED IN THE NATIONAL ELECTRICAL CODE NFPA 70 FOR INSTALLATION WITHIN THE UNITED STATES OR AS SPECIFIED IN THE CANADIAN ELECTRICAL CODE FOR INSTALLATION IN CANADA BLOCK DIAGRAM POWER SUPPLY 2avpc _ USB DEVICE PROGRAMMING ISOLATED ISOLATED RS485 R232 PORTA PORTA PGM PORT ISOLATED ISOLATED HOST A HOST B RS485 RS2
12. erface without the rear cover attached discharge static charges from your body by touching a grounded bare metal object Ideally handle the operator interface at a static controlled clean workstation Also do not touch the surface areas of the circuit board Dirt oil or other contaminants may adversely affect circuit operation A battery is used to keep time when the unit is without power Typical accuracy of the TS8015 time keeping is less than one minute per month drift The battery of a TS8015 unit does not affect the unit s memory all configurations and data is stored in non volatile memory To change the battery of a TS8015 remove power cabling and then the rear cover of the unit To remove the cover remove the 16 screws on the rear of the unit Then by lifting the top side hinge the cover thus providing clearance for the connectors on the bottom side of the PCB as shown in the illustration below Install in the reverse manner Remove the old battery from the holder and replace with the new battery Replace the rear cover cables and re apply power Using DSI8000 or the unit s keypad enter the correct time and date Please note that the old battery must be disposed of in a manner that complies with your local waste regulations Also the battery must not be disposed of in fire or in a manner whereby it may be damaged and its contents come into contact with human skin The battery used by the TS8015 is a lithium type CR
13. esent FLASHING RAPIDLY CompactFlash card being checked Unit is writing to the CompactFlash either because it is FLICKERING storing data or because the PC connected via the USB port has locked the drive 2 FLASHING SLOWLY GREEN BOTTOM FLASHING A tag is in an alarm state STEADY Valid configuration is loaded and there are no alarms present 1 The operator interface is shipped without a configuration After downloading a configuration if the light remains in the flashing state continuously try cycling power If the LED still continues to flash try downloading a configuration again 2 Do not turn off power to the unit while this light is flickering The unit writes data in two minute intervals Later Microsoft operating systems will not lock the drive unless they need to write data Windows 98 may lock the drive any time it is mounted thereby interfering with logging Refer to Mounting the CompactFlash in the DSI8000 User Manual Incorrectly formatted CompactFlash card present BATTERY amp TIME KEEPING WARNING EXPLOSION HAZARD THE AREA MUST BE KNOWN TO BE NON HAZARDOUS BEFORE SERVICING REPLACING THE UNIT AND BEFORE INSTALLING OR REMOVING I O WIRING AND BATTERY AND THE AREA IS KNOWN TO BE NON HAZARDOUS WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED CAUTION The circuit board contains static sensitive components Before handling the operator int
14. max Note For additional information on the communications or signal common and connections to earth ground please see the Connecting to Earth Ground in the section Installing and Powering the TS8015 Port to port isolation 500 Vrms for 1 minutes signal isolation 50V Ethernet Port 10 BASE T 100 BASE TX RJ45 jack is wired as a NIC Network Interface Card Isolation from Ethernet network to TS operator interface 1500 Vrms DIMENSIONS In inches mm 16 00 406 4 8 ENVIRONMENTAL CONDITIONS Operating Temperature Range 0 to 50 C Storage Temperature Range 20 to 70 C Operating and Storage Humidity 80 maximum relative humidity non condensing from 0 to 50 C Vibration according to IEC 68 2 6 Operational 5 to 150 Hz in X Y Z direction for 1 5 hours 2 g Shock according to IEC 68 2 27 Operational 35 g 9 msec in 3 directions Altitude Up to 2000 meters CERTIFICATIONS AND COMPLIANCES SAFETY IEC 61010 1 EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 IP66 Enclosure rating Face only IEC 529 Type 4X Enclosure rating Face only UL50 ELECTROMAGNETIC COMPATIBILITY Emissions and Immunity to EN 61326 2006 Electrical Equipment for Measurement Control and Laboratory use Immunity to Industrial Locations Electrostatic discharge EN 61000 4 2 Criterion
15. nal communications optional communications card CompactFlash card and other features programmed through DSI8000 In any case it is very important that the power supply is mounted correctly if the unit is to operate reliably Please take care to observe the following points The power supply must be mounted close to the unit with usually not more than 6 feet 1 8 m of cable between the supply and the operator interface Ideally the shortest length possible should be used The wire used to connect the operator interface s power supply should be at least 22 gage wire If a longer cable run is used a heavier gage wire should be used The routing of the cable should be kept away from large contactors inverters and other devices which may generate significant electrical noise A power supply with an NEC Class 2 or Limited Power Source LPS and SELV rating is to be used This type of power supply provides isolation to accessible circuits from hazardous voltage levels generated by a mains power supply due to single faults SELV is an acronym for safety extra low voltage Safety extra low voltage circuits shall exhibit voltages safe to touch both under normal operating conditions and after a single fault such as a breakdown of a layer of basic insulation or after the failure of a single component has occurred AN A disconnect device must be provided by the end user WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPME
16. nal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Do not use the controller to directly command motors valves or other actuators not equipped with safeguards To do so can be potentially harmful to persons or equipment in the event of a fault to the controller A CAUTION Risk of electric shock A CAUTION Risk Of Danger Read complete instructions prior to installation and operation of the unit CONFIGURED USING DSI8000 SOFTWARE UP TO 6 RS 232 422 485 COMMUNICATIONS PORTS 2 RS 232 AND 2 RS 422 485 ON BOARD 1 RS 232 AND 1 RS422 485 ON OPTIONAL COMMUNICATIONS CARD 10 BASE T 100 BASE TX ETHERNET PORT SUPPORTS MULTIPLE PROTOCOLS SIMULTANEOUSLY BUILT IN WEB SERVER AND FTP SERVER CLIENT USB DEVICE PORT TO DOWNLOAD THE UNIT S CONFIGURATION FROM A PC OR FOR DATA TRANSFERS TO A PC UNIT S CONFIGURATION IS STORED IN NON VOLATILE MEMORY 64 MBYTE FLASH COMPACTFLASH SOCKET FOR DATABASE RECIPE STORAGE AND DATA LOGGING 15 INCH TFT ACTIVE MATRIX 32K COLOR XGA 1024 X 768 PIXEL LCD 10 BUTTON KEYPAD FOR ON SCREEN MENUS THREE FRONT PANEL LED INDICATORS POWERED BY 24 VDC 20 SUPPLY RESISTIVE ANALOG TOUCHSCREEN Ce CONTENTS OF PACKAGE TS8015 Operator Interface Panel gasket Template for panel cutout Hardware packet for mounting unit into panel
17. onnected using a standard USB cable with a Type B connector The driver needed to use the USB port will be installed with DSI8000 The RS232 PGM port uses a programming cable made by Parker SSD Drives to connect to the DB9 COM port of your computer If you choose to make your own cable use the TS8015 Port Pin Out Diagram for wiring information The CompactFlash can be used to program a TS by placing a configuration file and firmware on the CompactFlash card The card is then inserted into the target TS and the TS is then powered up Refer to the DSI8000 literature for more information on the proper names and locations of the files USB DATA TRANSFERS FROM THE COMPACTFLASH CARD WARNING DO NOT CONNECT OR DISCONNECT CABLES N WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON HAZARDOUS USB PORT IS FOR SYSTEM SET UP AND DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT CONNECTION In order to transfer data from the CompactFlash card via the USB port a driver must be installed on your computer This driver is installed with DSI8000 and is located in the folder C Program Files Parker DSI8000 Device after DSI8000 is installed This may have already been accomplished if your TS8015 was configured using the USB port Once the driver is installed connect the TS8015 to your PC with a USB cable and follow Mounting the CompactFlash instructions in the DSI8000 user manual ETHERNET COMMUNICATIONS Ethernet communications can be
18. r Parker SSD Drives products one of the following brands of CompactFlash card must be used SMART Modular Silicon Systems SimpleTech SanDisk Parker Hannifin Corporation SSD Drives Division 9225 Forsyth Park Dr Charlotte NC 28273 USA Tel 704 588 3246 Fax 704 588 4806 www ssddrives com usa info us ssd parker com
Download Pdf Manuals
Related Search
Related Contents
Samsung AR09HSFNBWKN manual de utilizador Dust Detective Handbook ODYS Fino+ 21.5" 21.5" Full HD Black Philips Composite A/V to scart cable SWV3632S Samsung GT-S5600T Felhasználói kézikönyv Ref.: 1996 Description Conceptronic 128 KBPS (2X64 KBPS) PCI I Dell 2355dn Laser MFP Quick Reference Guide Copyright © All rights reserved.