1. 20 User Manual Eco X INITIAL START UP RESET e Insert the batteries and press R Reset with a pencil or a pointed object This operation will reset all the data and programmes previously set which will be initialised as default For all the days of the week this condition will set the following data SUN comfort temperature from 07 00 to 21 59 MOON saving temperature from 22 00 to 06 59 0900 e E Fe All the segments of the display will be switched on and the relay will be activated for about 3s The display will be switched off the clock will restart from 00 00 on Monday in Eco X W version only Until the first clock set the display shows the ambient temperature and the time flashing Regulation begins only after the time setting User Manual CLOCK SETTING Press D H and M to set respectively the day in Eco X W version only the hour and the current minutes Press one of these keys to increase their respective value of one M have the autorepeat function Once the clock has been set the chronothermostat moves to the automatic operation Note at any time it is possible to change the current day and time by pressing D H and M and following the above mentioned instructions LANGUAGE SELECTION AVAILABLE IN CHRONOTHERMOSTAT Eco X W ONLY Press OK for at least 3 s
2. particular provisions for thermosensitive command devices EN 60730 2 7 Automatic electric command devices for household and similar use Part 2 particular provisions for timers ELECTROMAGNETIC COMPATIBILITY EN 55014 1 General regulation on the immunity in household commercial and light industrial environments Electromagnetic compatibility Provisions for electrical appliances and tools and similar Part 1 Emission EN 55014 2 Electromagnetic compatibility Provisions for electrical appliances and tools and similar Part 2 Immunity 29 User Manual Eco X DIMENSIONS 9 888806 Eco X ener 30 User Manual Eco X MOUNTING 1 User Manual Eco X CONNECTION DIAGRAM 32 User Manual Eco X sjem Vemer S p A I 32032 Feltre BL Via Camp Lonc 16 Tel 39 0439 80638 Fax 39 0439 80619 e mail info vemer it web site www vemer it SPA V31500289 030 122006
3. Cronotermostato Digitale Eco X Digital Chronothermostat Manual User C Index W Safety Warnings W Technical Specifications Display and Programming W Initial start up Reset W Clock Setting Language Selection W Automatic Operation W Programme Setting W Temperatures Setting Manual Operation W Replacing the Batteries W Reference Standards W Dimensions Mounting W Connection diagram 7 User Manual Eco X Page Page Page Page Page Page Page Page Page Page Page Page Page Page Page 18 18 19 21 22 22 23 24 25 26 28 29 30 31 32 SAFETY WARNINGS During the installation and operation of the instrument follow the instructions below 1 The instrument should be installed by qualified personnel 2 Before gaining access to the connection terminals make sure that the conductors to be connected to the instrument or already connected are not live 3 Do not power or connect the instrument if any part of it is damaged 4 Follow the connection diagrams in this manual and on the instrument TECHNICAL SPECIFICATIONS Daily Eco X D or weekly Eco X W programming versions Power supply 2x1 5 V micro stylus alkaline batteries AAA e Autonomy 12 months minimum with alkaline batteries 1100 mA h at 23 C Charge reserve about 2 minutes for batteries replacement Battery charge condition indication with failed batteries signalling Output bistable rel
4. GF Cover for Eco X chronothermostat DISPLAY AND PROGRAMMING W LCD DISPLAY KEYS AND HANDLES The LCD display shows the following information 50 time programming with 24 SUN symbols and 24 MOON gt symbols related to 0 23 time 2 DAY weekly version only day of the week in 5 languages selected by the user 3 TIME shows the time HH MM 4 TEMPERATURE shows the temperature in C 5 FIRE shows the relay activation a9 User Manual Eco X sun O 88 0 Reset OK SUN 9 MOON SUN HANDLE MOON HANDLE day of the week setting in the weekly version only increases the hour field increases the minutes field resets the functions to the default values programming language selection exit to normal operating mode icomfort temperature indication during programming it sets the comfort temperature saving temperature indication during programming it sets the saving temperature comfort temperature regulation saving temperature regulation Hold down the keys to activate their respective operations During the programme or language setting if no key is pressed for 30s the chronothermostat returns to normal operating mode and memorizes the modified operations By pressing H or M the value in the field to be modified increases with constant acceleration
5. aving temperature see paragraph TEMPERATURES SETTING Once the programme has been set it is possible to move to the next hour and update the HOUR field the flashing graphic field will step up clockwise To modify the programme of a particular hour press H till reaching the chosen hour each time the key is pressed time increases of an hour without modifying the programme the autorepeat function is active then press or to set the temperature desired ET User Manual Eco X n Eco X W model only press 0 to change the day of the week each time this key is pressed the day increases of one Press OK to return to the automatic operation f no key is pressed for 30s the chronothermostat will abandon the programming function and memorize the modified settings Note During the programme setting regulation and relay operation are suspended TEMPERATURES SETTING Comfort SUN and saving MOON temperatures are set by means of two 3 4 turn handles Press O C 9 in TEMPERATURE field to display the temperature flashing set by means of the respective handle in the DAY field the word SET is displayed Rotate the respective handle to modify the temperature The temperature stops flashing for about 2s 25 User Manual Eco X Press a second time to return to the display of the temperature measured It is possi
6. ay with max 8 5 A 250V AC exchange contact 2temperatures SUN and MOON are settable by means of a trimmer SUN 2 C 30 C comfort temperature regulation MOON gt 2 C 22 C saving temperature regulation e ON OFF temperature regulation with fixed differential of 0 3 C Clock weekly daily Eco X W language selection for the display of the day of the week chosen between Italian English French German Spanish Programming resolution 1h Temperature measured resolution 0 1 C Precision 0 5 C Temperature measurement update every 60s Temperature measured 0 C 40 C Operating temperature 0 C 50 C Temperature regulation field 2 C 30 C e Storage temperature 10 C 65 C e LCD display with visualization of temperature time daily programme and relay activation state and day of the week in Eco X W only e Protection level IP40 Test on each device 18 User Manual Eco X Eco X digital chronothermostat Code Model Description VN161600 Eco X D Weekly chronothermostat White VN160800 Eco X W Daily chronothermostat White VN975900 Cover Aluminium raider CR Cover for Eco X chronothermostat VN976700 Cover Grigio iron AC Cover for Eco X chronothermostat VN977500 Cover Nero lux NR Cover for Eco X chronothermostat VN978300 Cover Blu lagon BJ Cover for Eco X chronothermostat VN979100 Cover Metallic
7. ble to return to the automatic operation by pressing OK too It is also possible to modify the SUN MOON temperatures without pressing the respective keys operating just the handles In this case the set temperature is not displayed Note If no key is pressed or if the handle is not operated for about 30s the chronothermostat will return to the automatic operation and memorize the modified settings MANUAL OPERATION Press O or for at least 3s to move from automatic to manual operation In manual operation the regulation temperature is prefixed in SUN 9 or MOON for each time of the day The operation type is indicated by the word MAN in DAY field and by all the suns and moons switched on Press O or to modify the regulation temperature 3s z r lt 5 9 MAN 9s ED 2 26 User Manual Eco X In DAY field the word SET is shown and the temperature begins to flash To change the temperature operate the respective handle as in the automatic operation e Temperature can be modified without pressing one of the C keys too In this case the set temperature is not displayed During the setting it is possible to move from SUN CE temperature to the MOON gt one and vice versa by pressing the respective key e Press O or or again to move back to the manual operation 30s after the last regulation the chrono
8. econds to modify the language display of the day of the week 2 User Manual Eco X The available languages are in order Italian ita English eng French fra German deu Spanish esp Press D H or M to select the language e tis possible to abandon the selection by pressing OK or after 30s from the last key pression AUTOMATIC OPERATION n automatic operation the temperature regulation is active and the LCD display shows the following information Current time HH MM Temperature measured Temperature unit of measure C FIRE 8 symbol if the relay is ON SUN or MOON gt for each time of the day as per current daily programme Day of the week in the selected language in Eco X W version 23 User Manual Eco X PROGRAMME SETTING Once the device is operating the chronothermostat is set with the default programme SUN 4 from 07 00 to 21 59 and MOON gt from 22 00 to 06 59 Press OK to modify this programme The display shows the word SET instead of the temperature TIME field shows the current time without minutes the SUN MOON symbol relating to the displayed time flashes and DAY field shows the day of the current week weekly version only Press C to set for the time displayed respectively the comfort or s
9. thermostat automatically returns to the manual operation In MANUAL operation it is possible to modify hours and minutes display SUN and MOON temperatures On the contrary it is not possible to modify neither the set programmes nor the selected language in Eco X W If the day of the week is modified in Eco X W version only you move back to the AUTOMATIC operation Press O Q for at least 3s to move back to the automatic operation 27 User Manual Eco X REPLACING THE BATTERIES e When the batteries are close to exhaustion the display will flash and show the word BAT in DAY field both in Eco X D and in Eco X W e The chronothermostat operates regularly regulation included e When batteries are removed the display switches off and all the functions are interrupted except for the clock update until the nex batteries are inserted E The maximum battery replacement time is about 2 minutes e When the new batteries are inserted the chronothermostat immediately restarts In case this does not happen press the Reset R key 28 User Manual Eco X REFERENCE STANDARDS W Conformity to the EU directives 73 23 CEE modified by 93 68 CEE low voltage 89 336 CEE modified by 92 31 CEE and 93 68 EEC EMC is declared with reference to the following standards SAFETY EN 60730 2 9 Automatic electric command devices for household and similar use Part 2