Home
POW-AD25GY User`s Manual
Contents
1. No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO LTD 05192004 03142002 Management No A 40 642 05192004_rev3 Parts No LYAW831
2. mounted in one touch Side view CONTEC Removal procedure 1 Lower the fixing hook for the unit to unlock it 2 With the fixing hook unlocked pull the lower part of the unit toward you Side view 3 By lifting the unit you can easily remove it from the DIN rail Side view POW AD25GY POW AD25GY User s Manual Connection Method Connecting the I O cables to the AC DC power supply unit Cables are connected to the AC DC power supply unit by means of detachable connectors that are provided as standard items Input unit compatible cables AWG 24 to 12 Output unit compatible cables AWG 28 to 16 The AC DC power supply unit and F amp elIT Series product can be cable connected using the detachable connector that is provided on either the unit face or the modulet face compatible cables AWG 28 to 16 Note Because the AC DC power supply unit generates heat a minimum spacing of 2 0 cm should be provided between the POW AD25GY and any adjoining units and care should be taken so that the ventilation holes are not covered able conmectear List of Options FAN Unit FAN FIT FAN Unit For 52 4mm width unit or module Copyright 2002 CONTEC CO LTD ALL RIGHTS RESERVED CONTEC CO LTD May 2004 Edition 3 9 31 Himesato Nishiyodogawa ku Osaka 555 0025 Japan Japanese http www contec co jp English http www contec com Chinese _ http www contec com cn
3. F amp eIT Series AC DC Power Supply Unit POW AD25GY User s Manual CONTEC CO LTD Congratulations on your recent purchase of a AC DC Power Supply Unit Copyright Copyright 2002 CONTEC CO LTD ALL RIGHTS RESERVED No part of this document may be copied or reproduced in any form or by any means without prior written consent of CONTEC CO LTD CONTEC CO LTD makes no commitment to update or keep current the information contained in this document The information in this document is subject to change without notice All relevant issues have been considered in the preparation of this document Should you notice an omission or any questionable item in this document please feel free to notify CONTEC CO LTD Regardless of the foregoing statement CONTEC assumes no responsibility for any errors that may appear in this document or for any results of using the product F amp elT is a registered trademark of CONTEC CO LTD Other company and product names mentioned herein are generally trademarks or registered trademarks of their respective owners Trademarks All company and product names that are referred to in this manual are generally trademarks or registered trade Handling Precautions This power supply is dedicated to the F amp eIT Do not use for the other devices Do not use or store the equipment in a hot or cold place or in a place that is subject to severe temperature changes Operating temperature range 0 to 40 C Do no
4. GY POW AD25GY User s Manual System Reference Specifications Specifications Input Voltage 85 to 264VAC 110 to 375VDC Current 100VAC 0 36A Typ I o 100 230VAC 0 26A Typ o 100 47 to 63Hz Rush current 100VAC 5 0A Typ o 100 230VAC 13 0A Typ o 100 Output Rated voltage 5 0V 45 Rated current 230VAC 4 6A Max 115VAC 4 2A Max Static input fluctuations 0 4 Max Static load fluctuations 1 M ax 10 90 Lload fluctuations Ripple noise 100mVp p Typ 20MHz Bandwidth fluctuations 140ms Typ LO0OVAC 1 0 100 110ms Typ 230VAC 10 100 20ms Typ 115VAC 0 100 100ms T yp 230VAC 1 0 100 Operates at 130 Min of nominal functions current auto reverting Other functions External dimensions mm 52 4 W x 64 7 D x 94 0 H exclusive of any protrusions Cooling method Natural air cooling Service life It is 2 years at the circumference temperature of 40 C It is 5 58 years at the circumference temperature of 25 C lo 75 Weight of the system unit 200g Installation method One touch attachment to a 35mm DIN rail The mounting mechanism is provided on the system unit as a standard item CONTEC POW AD25GY POW AD25GY User s Manual Installation Environment Requirements Requirement description Ambient temperature Oto 40 C Storage temperature 10 to 60 C Ambient Humidity 10 to 90 No condensation Floating dust particles Not to be excessive Corrosive gases No
5. does not normally occur but where conductive contamination may occur from time to time due to accumulation of dust or similar Typically the environment in an IP54 equivalent control panel in a factory control room or factory floor Pollution degree 3 Environment in which conductive dust or other contamination does occur and where conduction may occur due to accumulation of dust or similar Typically a factory floor environment Pollution degree 4 Environment in which conductive contamination such as rain or snow is always present An outdoor environment As described above if a POW AD25GY is housed in an IP54 equivalent control panel contamination level 2 can be achieved 3 Installation Requirements a Build in this power supply according to standard EN60950 which is a built in power supply b Installation category 2 Pollution Degree 2 c The protection earth point is FG pin of 115 230VAC connector in front of the case Ground this pin to the earth with the cable Nomenclature i conTEC Connector LED Indicator gt mmm 2 piece power input connector detachable J A dedicated plug as a standard item i h van E Po Screw in type cable connection 2 piece power output connector detachable rT FG A dedicated plug as a standard item tyeaerves Screw in type cable connection AC Input Ei LED Indicator PO ADSS 4 ON DC output on Power LED Power green OFF DC output off CONTEC POW AD25
6. mation will comply with the above directive Ultimate responsibility for determining how to comply with the low voltage directive and how to confirm compliance is the responsibility of the equipment manufacturer POW AD25GyY is an open type device a device designed to be housed inside other equipment and must always be mounted inside a control panel according to standard EN60950 To provide electrical shock protection for people such as operators who do not have the necessary level of electrical knowledge the control panel must include the following precautionary measures Installation category 2 CONTEC POW AD25GY POW AD25GY User s Manual 1 Electric shock protection a Lock the control panel to ensure that it can only be opened by persons with sufficient knowledge and training on electrical equipment b Incorporate a mechanism so that opening the control panel automatically isolates the power supply 2 Water and dust proofing The control panel is dust and water proof If dust proofing or water proofing is made inadequate insulation may deteriorate increasing the risk of insulation failure The insulation on the POW AD25GY is designed to deal with pollution degree 2 and therefore the unit should only be used in environments with pollution degree 2 or better Pollution degree 1 Dry environment with no conductive dust or other contamination Pollution degree 2 Environment in which conductive dust or other contamination
7. ne immunity Contact discharge 4kV IEC1000 4 21 evel 2 EN61000 4 21 evel 2 resistance Atmospheric discharge 8kV IEC1000 4 21 evel 3 EN61000 4 21 evel 3 Vibration sweep resistance resistance 80minutes each in X Y and Z directions S C0040 compliant EC68 2 6 compliant Impact resistance 15G half sine shock for 11ms in X Y and Z directions S C004 compliant EC68 2 27 compliant Class D grounding previous class 3 grounding Installation location Installing to the DIN rail the control boards etc as the power supply dedicated to the F amp elT T O Connectors Description Input MSTB2 5 3 STF 5 08 made by PHOENIX CONTACT Corp Laterally operable screw in type MC1 5 3 ST 3 5 made by PHOENIX CONTACT Corp Compatible cable AWG 28 to 16 8 0A rated current External Dimensions 1 2 CONTEC POW AD25GY Installation Method POW AD25GY User s Manual Mounting the AC DC Power Supply Unit on the DIN Rail Mounting procedure 1 Pushing the fixing hook with a flat blade screwdriver renders it into a lock enabled condition Press here to lift the fixing hook 2 Hook the AC DC power supply unit from the upper part of the DIN rail and press the lower part of the unit against the DIN rail Side view 3 The fixing hook is automatically locked and the unit can be
8. nstruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference at his own expense WARNING TO USER Change or modifications not expressly approved the manufacturer can void the user s authority to operate this equipment Product Configuration System unit 1 AC Power Supply input connector plug 1 Manual 1 DC Power Supply output connector plug 2 About the POW AD25GY POW AD25GyY is a power supply unit for providing DC power to the large F amp elIT series configuration It can be used world wide This AC DC power supply unit is carrying out the standard equipment of the DIN rail attachment mechanism to the main part like other products of this series and can install it simply and smartly A system can be easily built combining F amp elIT series product Compliance Requirements The low voltage directives require that devices operating from power supplies in the range 50 to 1000 VAC or 75 to 1500 VAC observe necessary safety precautions The following describes the main points to note so that installations using the POW AD25GY can comply with the low voltage directives Although this information has been prepared to the best of our ability based on the requirements standards and other stipulations contained in the regulations obtained by CONTEC we provide no guarantee that equipment manufactured based on this infor
9. t use or store the equipment in a place subject to direct sunlight or near a heating device such as a stove Do not use or store the equipment in a dusty or humid place Operating humidity range 10 to 90 RH no condensation As this product contains precision electronic components do not use or store in environments subject to shock or vibration Do not use or store the product near equipment generating a strong magnetic field or radio waves If you notice any strange odor or overheating please unplug the power cord immediately In the event of an abnormal condition or malfunction please consult the dealer from whom the equipment was purchased To avoid electric shock please do not touch the system with a wet hand Do not modify the unit CONTEC will bear no responsibility for any problems etc resulting from modifying this unit Do not open the unit casing CONTEC will disclaim any responsibility for equipment whose casing has been opened CONTEC POW AD25GY POW AD25GY User s Manual FCC PART 15 Class A Notice NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the i