Home
Optical DVI Daisy-chain Extender User`s Manual for the M5
Contents
1. DIT 1174 Je NIT Optical DVI Daisy chain Extender User s Manual for the M5 2000 amp 2001 Manual Contents Manual Contents Welcome Product Description System Requirements for Setup Installation Troubleshooting Maintenance Technical Support Product Specifications Warranty Information Regulatory Statements Pictorials Figure 1 Overall Optical DVI daisy chain system Figure 2 Connection of DVI cable and power adaptor in M5 2000 Figure 3 Connection of DVI cables to displays and power adaptor in M5 2001 Figure 4 Connection of duplex LC fiber cables Figure 5 Fiber Connection between two 2 M5 2001s 1 0 Manual Contents OO J O 1 D N mL Ll m md I Welcome Congratulations on your purchase of the optical DVI daisy chain extender consisting of a M5 2000 Optical DVI converter and multiple M5 2001 Optical DVI repeaters This manual contains information that will assist you in installing and operating the product Product Description The M5 2000 module converts DVI input into two channel optical signals and transmits over multimode glass of fiber cables with duplex LC plugs to the M5 2001 module Also the M5 2001 module repeats to the next M5 2001 module and at the same time distributes into two DVI outputs The combination of one 1 M5 2000 and multiple M5 2001 makes DVI daisy chain connection remotely placed at 500m 1 670ft in maximum between modules For the sa
2. following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 and 2 of FCC Rules EN 55022 55024 61000 3 for CE certification These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction guide may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Re orient or relocate the receiving antenna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult a service representative for help Properly shielded and grounded cables and connectors must be used in order to comply with FCC CE emission limits Changes or modifications
3. and repeater boxes plug correctly to the computer and display respectively Check if the computer and display are powered on and properly booted Ensure your graphic card is set at not higher than SXGA 1 248x1 024 at 60Hz refresh ratio Ensure the programmed EDID be compatible with that of the connected monitors Reset the converter and each of repeaters by de plugging and re plugging the power adaptors Re boot up the system after reconnecting the optical system cable Screen is distorted or displays noises Check if the graphic resolution is properly set Go to the display properties and tap the settings Ensure that the resolution sets less than SXGA 1 248x1 024 at 60Hz refresh ratio Reset the converter and each of repeaters or the system Power down disconnect and reconnect the optical system cable or DC power adaptors and power up Maintenance No special maintenance is required for the optical system cables and power supplies Ensure that the cables and power modules are stored or used ina benign environment free from liquid or dirt contamination There are no user serviceable parts Refer all service and repair issues to Opticis or its authorized distributor Technical Support and Service For commercial or general product support contact your reseller For technical service contact Opticis by email techsupp opticis com or visit its website at www opticis com 1 5 Troubleshooting Maintenance Technical Suppor
4. ke of right display on connected monitors the factory offers programming EDID of a user s monitor to the EEPROM in the M5 2000 Shipping Group of M5 2000 Optical DVI converter O The converter box One 1 Converter Box O AC DC power adapter One 1 12V 3A units including AC cord O User s Manual M5 2001 Optical DVI repeater O The repeater box One 1 Repeater Box O AC DC power adapter One 1 12V 3A units including AC cord On User s Manual Figure 1 Overall Optical DVI daisy chain system 1 1 Welcome Product Description System Requirements for Setup O Hardware requirements m You have a graphic controller card with a DVI port in your Windows Mac Mac is option or SUN system It should support the maximum graphic resolution feature of the display to be connected m Incase of using a computer no special memory size CPU speed and chipsets are required m Step by step connection of multiple M5 2001s is strongly recommended prior to install all M5 2001 boxes in a time O Software requirements m No special needs if the DVI graphic controller and display peripheral are operational with the platform s OS and application O AC DC Power Adapter Technical Advisory The power of M5 2000 and 2001 is designed to supply to each module of them by plugging to each of the power plugs 1 2 System Requirements for Setup Installation Important Please use the installation procedure below Improper or n
5. multimode glass of fiber Figure 4 Connection of duplex LC fiber cables Notice Please DO NOT look directly into the LC receptacles of M5 2000 and the OUT of M5 2001 boxes while they are powered on although they are regulated strictly enough to operate under the Laser Class classified by CDRH FDA for eye safety Step 5 If you have another M5 2001 follow as Step 3 and connect the duplex LC multimode fiber cables to the next M5 2001 as Step 4 The fiber connection is accomplished between the OUT of the prior M5 2001 and the IN of the next one You have to repeat Step 5 as many as you have Figure 5 Fiber Connection between two M5 2001s Step 6 Power on the computer and displays or connected devices if not ON Ensure the Link indicators light on presenting detecting signals and secure connection of LC duplex fiber cables and of the DVI cable in the M5 2000 box Tip 1 After initial installation as guided in the above we recommend you to power On and Off while all connections are set and the converter and repeaters are powered On Tip 2 Avoid hot plugging the converter or repeater boxes as this is not recommended practice with live digital voltages 1 4 Installation continued Troubleshooting The display displays only black screen Check that all AC and DC plugs and jacks used by external power supplies both Opticis and others are firmly connected Ensure that power bars are live Ensure that the converter
6. not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Certification for Safety The extension system is certified pursuant to IEC60065 and its AC DC power adapter is certified by UL1310 1950 60950 for North America cUL or CSA for Canada TUV CE amp GS for EU and PSE for Japan Certification of Eye Safety This laser product is inside implemented by using 1310nm 1550nm Bi di Transceivers manufactured by Opticis Co Ltd which are all certified by CDRH FDA referred in Accession Number 0210774 as classified in Laser Class1 1 8 Regulatory Statements 2007 Opticis All Rights Reserved Revision 1 1230
7. o operation may result if the start up sequence is not correctly followed Step 1 Carefully unpack the contents of the shipping group Before next step ensure that your graphic card is set at no higher than SXGA 1 280x1 024 60Hz in direct connection of copper DVI cables Step 2 With system power turned off connect the M5 2000 converter box to the DVI receptacle of a computer or a video controller by a DVI copper cable Plug the power adaptor in the shipping group and ensure its Power indicator lights on The Link indicator will light on after the graphic cards power on Recommend to power it after all connections are ready Notice Longer cables over 2m could deteriorate the overall graphic quality Figure 2 Connection of DVI cable and power adaptor in M5 2000 Step 3 In the same way as above connect the repeater box M5 2001 with two 2 DVI copper cables into each of displays Plug the power adaptor to the M5 2001 and ensure its Power indicator lights on Fa fo L by F j fa SF se Sd Les Figure 3 Connection of DVI cables to displays and power adaptor in M5 2001 1 3 Installation Step 4 Remove the module dust covers and connect a duplex LC fiber cable to LC receptacles of the M5 2000 converter and M5 2001 repeater as shown in Fig 4 Ensure plugging to the IN of two 2 duplex connectors in M5 2001 The OUT will be connected to the IN of the next M5 2001 Notice Please make sure that you should use
8. rchase from Opticis or its authorized resellers lf a product does not work as warranted during the applicable warranty period Opticis shall at its option and expense repair the defective product or part deliver to customer an equivalent product or part to replace the defective item or refund to customer the purchase price paid for the defective product All products that are replaced will become the property of Opticis Replacement products may be new or reconditioned Any replaced or repaired product or part has a ninety 90 day warranty or the reminder of the initial warranty period whichever is longer Opticis shall not be responsible for any software firmware information or memory data of customer contained in stored on or integrated with any products returned to Opticis for repair under warranty or not Warranty Limitation and Exclusion Opticis shall have no further obligation under the foregoing limited warranty if the product has been damaged due to abuse misuse neglect accident unusual physical or electrical stress unauthorized modifications tampering alterations or service other than by Opticis or its authorized agents causes other than from ordinary use or failure to properly use the product in the application for which said product is intended 1 7 Warranty Information FCC CE Statement for regulation of Electro magnetic emission This device complies with part 15 of FCC Rules Operation is subject to the
9. t Product Specifications M5 2000 and 2001 Optical DVI daisy chain Extender Ll Compliance with DVI standard supports DVI 1 0 of DDWG using fiber optic communication links Extension limit 500 m 1 670 feet for SXGA 1 248x1 024 24bit color at 60Hz refresh rate in ultimate operation Fiber optic Connection The converter M5 2000 and repeater boxes M5 2001 have duplex LC receptacles connected to two 50 or 62 5 125um or Multi Mode glass fibers cables Virtual DDC Offers the factory programming of EDID of users monitors considering all monitors to be connected be compatible with the programmed data Mechanical specifications of Uplink and Downlink boxes m Dimensions 180mm 125mm 30mm W H D m Weight 800 0 3 0 gram for M5 2000 and M52001 Environmental Specifications m Operating temperature 0 C to 50 C m Storage temperature 20 C to 70 C AC DC Power Adapter Ll Power Input Universal AC 85 264V 50 60Hz AC power cord with power jack Power Output 12 V 3 0 SMPS DC power Adapter Cord DC Jack amp length Core is 12 V and outer cylinder is GND Length is 18 5 cm AC Cord length 1 8m Certification PSE UL cUL FCC CE TUV GS i 1 6 Product Specifications Warranty Information 1 One Year Warranty Opticis warrants this optical DVI daisy chain Extender to be free from defects in workmanship and materials under normal use and service for a period of one 1 year from the date of pu