1. 5 Detect limit alarm event type Limit_Alarm is showed by software 6 Release limit alarm event type Limit_Recover is showed by software 7 Sensor is not connect with display event type Break_Alarm is showed by software 8 Sensor recover connection with display event type Break_Recover is showed by software If same type event is continually occurred only start and end alarm time is recorded And max records qty is 4000 when qty is exceeded new events will cover the old events according to FIFO principle 3 Display s function 1 There is a built in screen at the half left screen ANGLE is showed on the first row real angle value is showed on the second row and incline direction is showed on the third row 2 There are three type alarm events angle alarm open circuit alarm limit alarm If no alarm events ANGLE will be showed if all three alarms are happened at one time ALLAM will be showed When two different alarms happen following will be showed c AGBRK _AGLMT Open circuit AGBRK BREAK BRLMT Limit AGLMT BRLMT LIMIT Shanghai Zhichuan Electronic Tech Co Ltd 3 Real angle is showed on the half second row which is made of sign and numbers Default left inclination is with negative angle and right inclination is with positive angle 4 When inclination angle is less than 2 three upward arrows is showed on the left bottom of the screen and beeper is not aloud If inclination angle is in the range of 2 a
2. Shanghai Zhichuan Electronic Tech Co Ltd Order info ZCT CX05 RCO1 Guarantee Card Product Name Portable Inclinometer Part No ZCT CXO5 RCO1 Data of purchasing Time limit of Guaranteeing Company Purchasing Product SN Record of mending e Report Time e Reasons of fault e Reporter e Results of mending Information of customer holding this Guarantee Card Note This card is the basis for user enjoying maintaining and upgrades service Shanghai Zhichuan Electronic Tech Co Ltd Address 3 F Compositive Building No 1128 Denghui RD Minhang Shanghai China 0086 21 64908093 64908096 T 0086 21 64906992 F Postcode 201109 http 7www zc sensor com E mail sales zc sensor com
3. time press the power button to turn on or turn off the screen First press SET button can see the ANGLE become gray then we can change the alarm angle s decimals by button and J change the alarm angle s units by lt and gt When the required angle is set press button OK to save If not save and press SET again then SLEEP will change gray and enter into sleep time setting state and the alarm angle s set will not be saved When enter into sleep time set state press and to change sleep time s low digitals and press and to change sleep time s high digitals When the required time is set press OK to save If not press OK and press SET again will exit sleep time state and the set will not be saved Third time press SET to exit set mode and fourth time to press SET button to enter into alarm angle setting state and so on 8 After setting the sleep time and when the sensor enter into sleep time the screen will be closed at this time display will not response inclination alarm limit alarm and so on Press the power button for 3seconds the screen will light and exit the sleep state 4 Power and control line wiring Shanghai Zhichuan Electronic Tech Co Ltd Display s power wiring 8 36V DC Limit switch in Limit switch in Relay wiring It is not necessary to recognize wire colors for the sensor when the connectors are matched it is OK NOTICE 1 There are 4 wires of the power cable that is brown wi
4. ZCT CX05 RCO1 Inclinometer Specification V v oc Quiescent No load VCC 24V pem Alarm current VCC 24V See Operation parameter capacity 24V DC 250V AC Relaycontact 24V DC 250V AC 5 Work temprange Accuracy 2 Specification 7erotempdrift parameter Size sensor a pee pep C oa omes D A Shanghai Zhichuan Electronic Tech Co Ltd General description ZCT CXO5 RCO inclinometer system is designed and produced by ZC Tech It is with measuring range of 20 and made of sensor and display It is with zero set alarm angle set function and the built in clock chip realize the system log function which can be set and read by the connection PC and USB interface It can be used as safety monitoring record for construction machines Technical Parameters Features Entirely industrial device Stable and reliable performance Automatically log function Wide power supply and power reversion protection Application Engineering vehicle inclination measure and record Aerial lifts safety monitoring Dumper Shanghai Zhichuan Electronic Tech Co Ltd Remark 1 Quiescent refers to work current when power supply is DC24Vol and sensors angle is less than alarm angle Remark 2 accuracy refers to RMS value between actual angle and measuring angle gt 16 times EMC electromagnetic compatibility measure and test Performance Circumstance phenomenon Test
5. grade Test standard Static electricity contact 4 charging discharge voltage GB T 17626 2 IEC Static electricity 4 charging 61000 4 2 air discharge voltage 5 repeat frequency ine earth t ET surge line earth open voitage SY GB T 17626 5 IEC line line positive and negative of power line D 2 charging voltage GB T 17626 4 IEC P 5 50 TriTh ns 61000 4 4 1 2 50 Tr Th us 61000 4 5 User s manual 1 Connect the display with PC by the USB interface and run the software to set the following parameters 1 System time default is Beijing time and time can be detailed as seconds 2 Alarm angle default is 7 Current angle and time will be saved when it reaches or be greater than the alarm angle 3 Sleep time default is 10mins The whole system will enter into sleep state 10 mins after the sleep time is set or waking from last time sleep state 4 Set current angle as zero 5 Recover absolute angle 6 Read log 7 Clean log Shanghai Zhichuan Electronic Tech Co Ltd 2 Log function The following events will be saved in the system 1 Sensor enter into sleep state event type Sleep is showed by software 2 Sensor recover from sleep state event type code Wake is showed by software 3 The measured angle is reach or exceed set alarm angle event type Angle_Alarm is showed 4 Angle alarm is released measured angle is less than the set alarm angle event type Angle_Recover is showed
6. nd the alarm angle when in left inclination state there is a left toward arrow and three upward arrows when in right inclination state there is a right inclination arrow and three upward arrows The beeper sings in a higher frequency when the real angle close to alarm angle If inclination angle is greater than the set alarm angle when in left inclination state two left toward arrows and three upward arrows will be showed when is right inclination state two right arrows and three upward arrows will be showed At the same time beeper is singing for a long time and Relay is on 5 Two built in high capacity Relay is inside the display corresponding OUTPUT1 and OUTPUT2 when inclination angle is greater than the alarm angle common port and normal open port of the Relay are closed when inclination angle is less than alarm angle common port and normal close port of the Relay are closed inclinometer alarm signal output OUTPUT1 When limit alarm is happened common port and normal open is closed when limit alarm is released common port and normal close are closed and limit alarm signal output OUTPUT 6 On the right half of the screen display content are Date and week info is showed on the first row time is showed on the second row alarm angle is showed on the third row sleep time is showed on the fourth row 7 There are seven buttons on the display Power on 7 Y lt gt SET OK Alarm angle and sleep time can be set by buttons Long
7. re black wire gray wire yellow and green wire Power connect with brown wire and Power connect with black wire Gray and yellow green wires are couple switch input signal the couple wires are with two state connection state and not connection state If connection display can detect and give alarm signal if not connection it is viewed as default normal state The two wires can t receive input or the sensor will be damaged 2 After the indicator is connected with the power connect the indicator with PC by USB interface then the log info can be read USB interface is for data transmit and not for charge Size Unit mm Sensor s Size Shanghai Zhichuan Electronic Tech Co Ltd 20 0 Sil Sensor s installation diagram D n Display s diagram C J Le 100 E 2 4 5 m Inclinometer ser A fok Tos a Lv gt E l 160 Sensor The cable is 0 200 The connection of M12 connector The cable is PS ian The a M12 connector A The cable is 10m The cablei 3m Power L and switch Display f Theoutput2 cable is 3m The outputl cable is 3m 1028 60X2 192 N d Shanghai Zhichuan Electronic Tech Co Ltd Connection diagram