1. montena emc sa Pulsed Current Injection Test System according to MIL STD 188 125 1 amp 2 System Description Version 1 0 Montena EMC 1 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http www emc montena com A montena montena emc sa Table of content 10 2 11 12 13 13 1 13 2 13 3 13 4 13 5 13 6 Montena GMC raisa A A A AE EEN 3 Bien Re KEE 3 NEMP TEST SYSTEMS REFERENCES uaaaaununnnnunnnnunnnnnnna nunnana nnana Eana LEALL L LARA LEA RALEA ARA LEARA CEARA CEARA LEARA CEARA L RARAC Anaran 4 THER MILS D REFERENCE EE 6 PCI test system description E 7 Pulse generators and control units ccceeeeeeeeeeeeeeneeeeeneeeeeneeeeeeeeeeseeeeseeseeseeseeneeseeneeseenessensenes 8 SHORT PULSE GENERATORS amp CONTROL UNITS cccccecececcccccecccecccccccececeaececceseaeaesceseceaeaeseeneaesteneeaescsneeauseseenes 8 INTERMEDIATE PULSE GENERATOR amp CONTROL UNITA 12 CHARGE INE PUGS ER SA DEE AE 13 P Se COU in e TEE 14 COUPLING OF THE SHORT PULSE oasaauauauuueuunnnnnnnuunnun uann n anaana anan LLALL EA AREAL LEEA EAR REAA LELA LAA REAR RELA LARREA REAA RAA ALAKRA a nannat 14 COUPLING OF THE INTERMEDIATE PULSE ireira a a a e 15 COUPLING OF THE CHARGED PINE PULSE eege eegend 15 Ieren 16 DECOUPLING OF THE SHORT TEE 16 DECOUPLING OF THE INTERMEDIATE EEN 17 DECOUPLING OF THE CHARGED LINE PULSE ccccceccececcececcaceccaceceaceccaceteceeueceeuene
2. Controller Receiver Data acquisition Oscilloscope amp Analysis P C TE Printer Shielded Measurement Container Figure 4 Schematic of a typical PCI test setup installation The pulse penerators deliver the high energy pulses either directly or through coupling devices in the cable under test The pulse enters the facility under test through the point of entry protective devices An oscilloscope collects the measurements from the current and voltage sensors for display and eventually storage in the control PC In order to ensure correct measurement the sensors are connected using fibre optic links The measurement and control systems are installed in a shielded measurement container When not used all the test equipment can be stored in the transportable shielded measurement container Pulse shapes Montena s PCI test system is able to perform pulsed current injection tests according MIL STD 188 125 1 amp 2 except for the long pulse renne memede pulse Charge ine pulse 7 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http www emc montena com k montena montena emc sa 3 Pulse generators and control units The test system comprises four pulse generators designed and built by Montena The generators can be directly controlled and remotely controlled via a PC 3 1 Short pulse generators amp control units To fulfil the test
3. 15MHz 1MOhm Digital Oscilloscope The proposed oscilloscope has following characteristics e 4channels digital oscilloscope e 2 GHz bandwidth e 5Gs s 10Gs s max 19 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http www emc montena com k montena montena emc sa 8 Control and data acquisition system 8 1 PC GPIB interface amp printer The proposed system comprises e One DELL pc e Intel Core2 Duo processor 2 4 GHz e Windows XP professional or Vista Business e 160 GB hard drive e 22 monitor 1680 x 1050 e One color laser printer e A4 color printer e 600 x 600 dpi e Upto 12 pages per minutes 16 monochrome e One GPIB PCI card model for the Desktop computer 20 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http www emc montena com montena montena emc sa 8 2 Data acquisition software This software is developed by montena with Labview specifically for this test setup trititi tires aa em CU t LL ESsss e SE E ai f HZH Bt 223233233 bebe ome nN KS Hii P gss ssas Di Gi z oe cen In s S Oa kri 64604 di Hin ai fs P LW y E elibetbeted seedehete p as ir Sale 72 DE 2207 abbaia aj SLM 2000 17 29 00 CURRERT LIMIT FREQUENCY ORAFH Lm Free I Erem Hr CALIIEATI
4. GESEIS ee EE EE EE EE 30 TEGHINICAL ASSISTANG EEN 30 WARRANTY ccccececcececcaceccceccaceceaceceaceceaceneaeeneaseneaeeneaeeeeueaeeueceeueaseneneeueaeuneaeeneaeeneateneaesneaeeneaesneaeataeeneuneaeaees 30 Version 1 0 11 08 2008 V Marketing Prospectus_produits SystemDescriptionDocuments PCI_ Tests_System_Description doc 2 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http Awww emc montena com montena montena emc sa 1 Montena emc Since its foundation in 1978 montena emc has earned a worldwide reputation for its leading edge skills in the fields of high voltage high frequency and electromagnetic fields Montena emc is number one EMC test lab in Switzerland with a team of 35 people 23 engineers With two large anechoic chambers an open area test site and multiple shielded rooms montena can test and validate all kinds of equipment Figure 1 Montena emc headquarters helicopter in one of montena s anechoic chamber Montena emc laboratory is accredited by SAS Swiss Accreditation Service for the calibration of EMC measuring devices as well as for the verification of the electrical safety of equipment and devices according to European Union directives and to Swiss legislation Montena can count on highly specialized specialised know how in the field of electromagnetic compatibility These skills are put to good use in our EMC laboratories as well as in the dev
5. 2 Coupling of the intermediate pulse Because of the low frequency content of the intermediate pulse neither capacitive nor inductive coupling is possible This is due to the very high capacitance inductance required for the coupling efficiency In addition these very high capacitance inductance will drain high current from the device or from the source connected to the line under test Therefore the methods of coupling will be the following e On shielded cables direct connection to the generator e Onmains AC DC supply connections direct coupling to the pulse generator The mains source or the auxiliary test equipment must be powered through an isolating transformer in order to force the current of the pulse to flow in the protective device In this way the external load is isolated The intermediate pulse generator will be equipped with 4 independent outputs which will allow the coupling on 4 lines The pulse will be injected on 1 wire to ground or 2 3 or 4 lines common mode e On signal data telecom cables 1 A 4 wires 60 Vac 1 A Like already explained above capacitive inductive coupling cannot be used therefore a direct coupling will be carried out through the 4 outputs of the generator A transformer could also be used to isolate the connected equipment from the external world Summary we recommend to use direct coupling No specific coupling device is proposed Eventually a A 60 A 230 Vac isolating transforme
6. AC power line filter for 4 lines 3L 1N 400 230V 50 60Hz for up to 40Amp DC power line filters 2 two x NEMP DC power line filters for a DC powering up to 30V DC 10A Data line filters 4 two x NEMP fast data protectors up to 155 MBit s For a single Ethernet 10 100 MBit s application two 2 protectors are necessary one protector for one wire pair Digital telephony line filters 2 two x NEMP low to medium data rate protectors up to 2MBit s VHF test filters 2 two x NEMP VHF antennas lines filter DC 1000 MHz 26 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http Awww emc montena com k montena montena emc sa 12 PCI simulation software In order to estimate the protection effectiveness of systems a simulation software is provided It allows to perform extrapolation of the performed measurements The solution includes more or less simple CAD computer aided design tools and importation tools from most common mechanical tools for instance Solid Works But a full CAD might be required for the simulation of complicated structures not included in the quotation A good working station windows based and screen with a selected graphic card are proposed as an option in the quotation The proposed package fulfils all the requirements with 2 separate softwares e avery complete Finite Difference Time Domain FDTD simulator e an integrated
7. CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http www emc montena com 8 Montena montena emc sa e The warranty period starts at the signature of this acceptance document 13 4 Maintenance No periodical maintenance other than calibration of the measurement equipment is required On customer request montena can offer this calibration service with support of montena s authorized local representative 13 5 Technical assistance Montena has sold many NEMP systems in Asia and montena s engineers are regularly in Asia for installation system enhancement technical support or training This offer comprises two onsite technical assistance visits Sdays during the warranty period For simple technical assistance montena s engineers are available for remote assistance by phone and e mail 13 6 Warranty A warranty of 24 months is included in the price The warranty period starts at acceptance of the test system SAT 30 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http Awww emc montena com
8. ON OFF PULSE EM ENCY i e j Figure 7 Picture of a similar pulse generator based on the same technology CHARGING VOLTAGE Preliminary specifications of the intermediate pulse generator short circuit Intertace am complies with EN61010 1 Safety circuit loop 24 Vac 500 MAmax 12 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http Awww emc montena com 7 ko montena montena emc sa 3 3 Charge line pulser This generator is based on a variable charge line In order to adjust the length of the charge line to the quarter wavelength of the applicable frequency special coaxial cables must be connected to the pulse generator on the rear side A set of 9 cables are supplied with the generator to cover the frequency range of 30 to 300 MHZ Pulse Generator Control Unit MCU4 E E E HV ON OFF LOCAL INTERLOCK Figure 8 Picture of a similar pulse generator Preliminary specifications of the charge line pulser MIL STD 188 125 2 charged line Pulse length FWHM of the current on 50 ohm 30 40 50 75 100 150 200 250 and 300 MHz Triggering of the generator manually or by the remote control RS 232 Power rating 210 250 Vac 50 60 Hz 300 W MC complies with EN 61326 1 complies with EN61010 1 Storage working temperature 5 50 C 15 45 C Environment inside use outside use only by good weather 13 30 montena emc sa CH 1
9. delivering up to 300 kV in open circuit and more than 5 KA in short circuit It comprises the high voltage Marx unit and the control unit High voltage unit Control unit of the generator Figure 6 Picture of a similar gt 300kV Marx generator 10 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http Awww emc montena com montena montena emc sa Preliminary specifications of the short pulse Marx 300kV generator Pulse length FWHM of the current 900 550 ns short circuit Pulse length of the voltage open circuit defined by the load connected to the output Triggering of the generator manually or by the remote control Power rating 210 250 Vac 50 60 Hz 500 W 1 phase Safety complies with EN61010 1 Safety circuit loop 24 Vac 500 MAmax Dimensions control unit about 44 x 53 x 35 mm D x W x H Dimensions generator about 1 2 x 0 5 x 0 5 m I x w xh Storage working temperature 5 50 C 20 40 C Environment inside use outside use only by good weather and protected from the direct sunshine 11 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http www emc montena com k montena montena emc sa 3 2 Intermediate pulse generator amp control unit This generator is built using a direct discharge of high voltage capacitors PULSE GENERATOR 12K 5 200 f E e en f HV
10. of the isolating capacitive coupler are the following A Isolating capacitive coupler for the mains supply SCC 16 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http Awww emc montena com k montena montena emc sa B Isolating capacitive coupler for the signal data telecom Nominal voltage 50 60 Hz DC 230 Vac or 60 Vac Nominal voltage 400 Hz 110 Vac Nominal current 50 60 400 Hz DC 1A 4 Signal cut off frequency 3 dB Wee me OSO Number of lines E 5 2 Decoupling of the intermediate pulse Because the frequency content of the pulse is the range of some Hz to some kHz it is not possible to use isolating devices The signals and even the mains 50 60 Hz will be blocked by the decoupling devices Finally the size weight and price of these devices will be prohibitive 5 3 Decoupling of the charged line pulse Because the pulse is injected directly on the coaxial connection isolating devices are neither possible nor needed 17 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http www emc montena com k montena montena emc sa 6 Termination loads A set of 2 50 and 300 ohm termination loads are usually proposed as option These loads can be connected to the end of the tested lines inside or and outside the protected area to terminate the line and absorb the injected curre
11. specifications gt 5000A with 60 Ohm the short pulse generator has to deliver up to 300 kV Additionally to be able to test different type of POE protecting devices it should be possible to perform tests at lower voltage some tens of kV As it is not possible to design a Marx generator for the required voltage range 10 kV 300 kV two generators are proposed e A 80kV direct discharge pulse generator 10kV 80 kV e A 300kV high voltage Marx generator 100 kV 300 kV The output impedance of the short pulse generator is a few Ohms only It is then possible to generate the required 5 kA without having to deliver a very high voltage Only in the case where the high voltage is desired for instance to test high and middle voltage points of entry of building or installations where the high voltage is required to eventually reach an isolation breakdown the 300kV short pulse generator is required As this generator is quite expensive it is usually proposed as option and is separately priced The short pulse generators are delivered with a 60 Ohm dumy load This load is intended for either e Terminate a cable under test with a load supporting the high voltage pulse e Calibrate the pulse generator with a load supporting the high voltage pulse e Increase the output impedance of the pulse generator to the required 60 Ohms Direct Discharge 80kV Short Pulse Generator This generator is built around one stage of high voltage capacit
12. 26 411 93 33 fax 41 0 26 411 93 30 http www emc montena com k montena montena emc sa A demo version with restricted performances and library is available on the website of the company www semcad com simulation index php 2 Schematic editor and simulator Micro Cap 9 Micro Cap 9 is an integrated schematic editor and mixed analog digital simulator that provides an interactive sketch and simulates environment for electronics engineers Since its release in 1982 Micro Cap has been steadily expanded and improved Micro Cap 9 the ninth generation blends a modern intuitive interface with robust numerical algorithms to produce unparalleled levels of simulation power and ease of use Nothing else comes close This software is used by Montena emc for 15 years It is easier to use compared with PSpice for instance and gives similar results Micro Cap 9 is compatible with PSpice SPICES etc In addition to the comprehensive library included in the package SPICE models can be downloaded from the components manufacturers The offer comprises e 1x Microcap 9 Windows XP or Vista e Dongle for 1 user e CD and manual No training is included in the quotation Because this software is easy to use training course are not required in our opinion An evaluation version is available on the website of the company www spectrum soft com It is limited to 50 components anywhere from 0 to 300 slower than the professional limited
13. 728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http www emc montena com montena montena emc sa 4 Pulse coupling devices The PCI test system is designed to allow the injection of the different types of pulses on 3 typical types of cables connexions e shielded cables e mains AC DC supply 2 wires 50 A 230 Vac or 60 Vac e signal data telecom cables 4 wires 1 A 60 Vac The coupling can be inductive or capacitive or direct 4 1 Coupling of the short pulse Due to the high voltage of the short pulse generator and the rather long duration of the pulse the Capacitive coupling requires a capacitor having a high capacitance and large dimensions The direct coupling can be used on shielded cables and similar metallic connection penetrating inside the protected area A Inductive coupling The specifications of the inductive coupler are the following Figure 9 Picture of the inductive coupler Specifications of the short pulse inductive coupler Frequency range 500 kHz 30 MHz Maximum peak voltage 1 500 ns typ 50 kV max 100 kV wee mn O 14 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http Awww emc montena com k montena montena emc sa B Capacitive coupling The capacitive coupling is combined with the isolating network in a same cabinet Therefore please see the chapter 5 1 Decoupling of the short pulse 4
14. ON RESULT SUNMREARS Tei freq Lim Cer jA Chang Yoki p Mann Cur IW emri 1 kf BP klix IO Hrs ap klix dl HIN Lao Ab Jore Jore Inte Inte IS A n ERT montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http www emc montena com DES D 1 IH HEN HK bk HK 1208 Ta L d EN F SE EE It 2 Figure 11 Example of a automatically generated test report 21 30 k montena montena emc sa The proposed software will be built with the existing basic blocks developed by montena to control the generators and the measurement equipments to collect measured data and to process the data for display and automatic report generation The software contains calibration panels to set the correction factors of sensors and transmission links The software will be designed according to the specific needs of the PCI test system operation and will be presented to the end customer for approval before its final implementation Montena delivers the software as well as the source code the end customer has then the possibility to extend modify this software according their future needs Of course montena can also be mandated for these eventually future adaptations 22 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http Awww emc montena com montena montena emc sa 9 Shielded container The proposed shielded conta
15. circuit editor and simulator The global method of working is 1 to use the FDTD to calculate the electromagnetic field distribution in the space the coupling inside structures like shielded cables and enclosures and to calculate the induced current and voltage and 2 to use the circuit simulator to calculate the effect of protective devices non linear circuits included the current and voltage on electric electronic circuits etc Remark the selected FDTD simulator SEMCAD X see below will soon include a coupled circuit SPICE EM simulator Proposed products 1 FDTD simulator SEMCAD X SEMCAD X is the latest generation of 3 D FDTD amp FIT finite integration technique full wave simulation software offering unprecedented levels of user friendliness soeed amp memory efficiency Its application range has been greatly extended by e g effective GA generic algorithm optimization of parameterised CAD derived structures and superior speed gt 50x faster than others This software is used by Montena emc for more than 2 years It gives excellent results and is rather easy to use The offer comprises e 1x SEMCAD X axware 500 package Windows XP professional 64 bits e Hotline and support for 1 year e Dongle for 1 user e CD and manual e aXware FDTD hardware accelerator No training is included in the quotation Training courses are regularly organised 27 30 montena emc sa CH 1728 Rossens phone 41 0
16. component library no Model program and some of the advanced features are not available This version can be used after purchasing the full version one seat version by other persons as a viewing tool or for testing simple adjustments on circuits developed with the full version The combined solution will have the following features 1 HEMP interaction on cables 2 Shielded cable and transfer impedance analysis 3 Circuit simulation 4 Volume shield analysis 28 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http Awww emc montena com k montena montena emc sa 13 Services amp Support 13 1 Manuals and documentation The provided documentation comprises e Asystem level installation and user manuals one paper copy CD e Installation and user manuals of each delivered equipment CD e An installation and user manual for the data and acquisition software one paper copy CD e Source code of the data and acquisition software CD e Installation and user manual for the PCI simulation software CD 13 2 Onsite installation and training Montena emc provides worldwide onsite installation performed by montena s engineers with help of skilled and unskilled workmen provided by the customer When required site preparation works have to be organized by the customer in coordination with montena emc This site preparation work must be of good quality must fulfil montena s r
17. elopment and construction of various kinds of equipment In the field of high voltage and high frequencies montena s engineers are masters of the techniques used to generate rapid pulses with fast rise time including those to endow them with special characteristics 1 1 Products Montena emc designs builds and markets equipment and accessories for EMC tests The range of products includes antennas TEM cells striplines field sensors all kind of pulse generators test benches etc Montena s high voltage pulse generators are mainly used for EMC tests ultra rapid imaging and pulsed light decontamination Montena also builds pulse generators according the custom specific needs 3 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http www emc montena com e montena montena emc sa Figure 2 some montena emc products 1 2 NEMP test systems references In the past years montena has designed build and delivered many test installations for both conducted and radiated susceptibility NEMP tests The list below shows typical examples of delivered test installations NEMP test generator 75 kV 2 8 25 ns with control unit NEMP test generator 320 kV 2 8 25 ns with control unit NEMP test generator 12kV 5 200 ns 4 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http Awww emc montena com montena emc sa NEMP test generat
18. eneaesueacentaesneaesneatsneaeeneanenears 17 Termination lOAS cccceccececceccnceccscencencecencencecencenceneeeeneeneeneeneseeseeneeceseuaeeneseeseeneeceneeneseeseseeseens 18 SY SLOT MONILO NG EE 19 Control and data acquisition SYSTOM ccccceeceeeeeeeeeeeeeneeeseeneeeseesneeeeeeneeeseaseeeeeeneeseneneessonenees 20 PC GPIB INTERFACE amp PRINTER ananannnnannnnnnnnnnnnnnnnnnrnrnnrnnnnrnrinrnrnnrarnn ranana rnnr annarar A nananana nan A nananana annaran 20 DATA ACQUISITION SOFTWARE sicscssscescavcccsscensscesancndawccasdseaeusie acuicaencedbeseandeedsunbanlncsius scuissnenaawecaeaetvesseebeslesawevaaeses 21 Shielded COMA EEN 23 Universal instruments savicidicenescsasaccccccccccdacavascccwssvarcecdavenuassasascnedevescnacnsacvwasuesaatadcseesweecusarcntccbanst 25 B IS ee 25 OTHER INSTRUMENTS amp ACCESSORIES aasuuuuuuennuunuunnnnnnn enana anaua r naaa an LLALLA ALAARA RRELA LARERE RELA LALALA REAR REA RLAR Ranna annt 25 Electric POE protective devices cccccccceeeeeeeeeeeeeeeeeaeeeeeneeseaseeeeaseeseaasesaaeeeoaneesoenessaaeesoneenes 26 PCI simulation software cccccceccecececcnceccccncencececenceceneecuneaceeenesauaeaceeeaeeauneseeceseuaeacecenesannenesasees 27 oie ox toes SUPPO EE 29 MANUALS AND DOCUMENTATION unner anana a anena ALERE ELEELE REEERE EELEE RREA RR EEE AREER REER R EREEREER aLa annann 29 ONSITE INSTALLATION AND TRAINING eet eege Eege Ee Eesen 29 YS RC CN Ee e ors ls waned EE EE UE E 29
19. equirements and must be completely finished before the beginning of the installation by montena emc In this project no special site preparation is required A comprehensive training session is offered and will be given directly after installation This training includes e the test system installation operation and maintenance This training will be provided by an engineer from montena e the simulation software installation and operation This training will be provided by an engineer from the simulation software providers under the coordination of montena The content of the training sessions will be defined according to the end customer desires 13 3 System acceptance The test system acceptance procedure is performed with a verification of the generated test pulses and comprises e Ameasurement of the generated current and voltage pulses e Ameasurement of residual current and voltage pulses behind the provided NEMP filters e Acomparison with the typical specifications of the filters The acceptance comprises two phases e AFAT factory acceptance test at Montena in Switzerland to demonstrate the system performance e One week for 2 people from the end customer e Travel and lodging are at the end customer expenses e ASAT site acceptance test performed at the end customer location after the system installation e Anacceptance report is delivered and signed by both the end customer and montena 29 30 montena emc sa
20. iguration during the execution of the project 24 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http Awww emc montena com k montena montena emc sa 10 Universal instruments 10 1 Dummy loads The dummy loads are to be used with the pulse generators as e serial resistor to limit the pulse current or e termination load for measurement of the current voltage pulse under well know conditions Following termination loads are offered e 1x60 Ohm termination load 300kV 600J included with 300kV short pulse generator delivery e 1x60 Ohm termination load 80kV 200J included with 80kV short pulse generator delivery e 1x10 Ohm termination load 10 Ohm 1800J e 1x50 Ohm termination load 10J 10 2 Other instruments amp accessories The system is delivered with all required measurement cables and other accessories as attenuators to perform the test according to the test setup presented in Figure 4 Schematic of a typical PCI test setup installation of this document Additional cables attenuators and optical fibres are proposed as spare parts 25 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http www emc montena com k montena montena emc sa 11 Electric POE protective devices A set of NEMP filters is offered to perform FAT SAT and other types of calibration or reference tests AC power line filters One NEMP
21. iner is provided by RUAG RUAG Land Systems Ltd Allmendstrasse 86 3602 Thun Switzerland Phone 41 332 282 111 Fax 41 332 284 783 sales landsystems ruag com www ruag ch RUAG is a Swiss company active in the Aviation amp space Defense amp security and in Ammunition Since decades RUAG delivers NEMP shielded containers for civil protection and military applications The container is a standard 8 ft x 8 ft x 20ft transportable container as shown in the picture below Figure 12 Typical NEMP container from RUAG The container has the following equipment e Walls and ceiling are made of steel e Door without window e Wooden floor with non slip and abrasion resistant vinyl flooring e Under floor protection outside e Electrical installations 5 x double 230V and 5 x RJ45 for 5 working places e Air conditioning 4 5 kW e External power supply through lightning protection box and insulating transformer 230V 35A e Coaxial feed through connector e Optical fibre cable entry e Standard locking system and is delivered with following furniture e 1x19 rack 600 x 700 x 1800 mm e 1 x table for 5 working places with 5 x chairs e 1x3 drawers file cabinet 23 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http www emc montena com k montena montena emc sa Figure 13 Proposed internal furniture It remains always possible to define the exact internal conf
22. nt pulse They are not applicable to the AC DC supply The termination loads consist of a box containing 4 resistors for 4 independent lines The specifications are the following Maximum peak voltage 20 kV Number of channels 4 number of resistors per box The set of termination load consists of e 2 boxes 1 spare of 4 resistors of 2 ohm for signal data telecom e 2 boxes 1 spare of 4 resistors of 50 ohm for signal data telecom e 2 boxes 1 spare of 4 resistors of 300 ohm for signal data telecom 18 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http Awww emc montena com k montena montena emc sa 7 System monitoring The test monitoring comprises current and voltage sensors an oscilloscope and a PC with its software for automatic control data acquisition and automatic report generation Current sensors Required are two current sensors one measuring the injected current and one for the residual current Residual voltage sensor In order to have a good measurement sensitivity two residual voltage sensors are proposed A 1000x probe and a 100x probe Optical link transmission For reliable measurement the transmission has to be immune to the generated field A fibre optic link is then used for each sensor The proposed optical transmission comprises 4 links e 3x Acquisition Module 1 kHz 1 GHz 50 Ohm e 1x Acquisition Module 6Hz
23. or 75 kV 2 8 25 ns with radiation line 1 8 m high for test according to MIL 461E RS105 NEMP test radiation line 12 m high NEMP test generator 120 kV 2 8 25 ns with radiation line 2 m high NEMP test generator 230 kV 2 8 25 ns with radiation line 3 6 m high montena emc sa 5 30 CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http www emc montena com _ montena montena emc sa 1 3 Other MIL STD references Montena has developed and sold turnkey test setups for other MIL STD 461 test systems as RS 101 CS 101 CS 114 CS 115 and CS 116 Figure 3 CS116 amp CS115 test setup from montena 6 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http Awww emc montena com montena montena emc sa 2 PCI test system description Montena s EMP PCI test system is design to perform Pulsed Current Injection tests according MIL STD 188 125 1 amp 2 The test setup comprises following elements Facility or System Under Test Cable Under Test POE Protective Device Injected Residual Residual Current Current U Voltage Sensor Sensor Sensor Internal Fiber Optic Dummy Load Transmitter Or Equipment Isolation Device Coupling Device External Dummy Load Or Equipment Pulse Generator Fiber Optic Transmitter Pulse Generator Fiber Optic
24. ors directly charged from a high voltage power supply The system comprises the high voltage unit and the control unit High voltage unit Control unit of the generator Figure 5 Picture of a similar gt 75kV direct discharge generator 8 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http Awww emc montena com i montena montena emc sa Preliminary specifications of the short pulse 80kV direct discharge generator Standard MIL STD 188 125 1 amp 2 direct capacitor discharge Peak open circuit voltage 10 kV to 80 kV positive only Peak short circuit current 5 kA Pulse shape double exponential waveform Pulse length FWHM of the current 900 550 ns short circuit Rise time of the voltage open circuit Pulse length of the voltage open circuit defined by the load connected to the output Triggering of the generator Interface RS 232 Safety complies with EN61010 1 Safety circuit loop 24 Vac 500 mMAmax EMC complies with EN 61326 1 Storage working temperature 5 50 C 20 40 C Dimensions control unit 42 x 53 x 15 mm D x W x H Dimensions generator 600 x 260 x 240 mm L x W x H Generator weight 50 kg with oil 9 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http www emc montena com montena emc sa Marx 300 kV Short Pulse Generator This generator is built around a Marx generator
25. r could be proposed as an option 4 3 Coupling of the charged line pulse The coupling of the charged line pulse will be carried out by direct connection of the coaxial cable connection to test to the pulse generator Summary No coupling device is proposed 15 30 montena emc sa CH 1728 Rossens phone 41 0 26 411 93 33 fax 41 0 26 411 93 30 http www emc montena com k montena montena emc sa 5 Isolating devices The purpose of these decoupling devices is to isolate the external load the mains the auxiliary equipment etc from the pulses injected by the generators Unfortunately using isolating devices is not always possible due to the fact that these devices can also block the signal if their frequency is in the same range than the pulse So we recommend generally to inject the pulses only on lines and connection which are not connected to active auxiliary equipment 5 1 Decoupling of the short pulse Due to the high voltage of the short pulse generator the decoupling requires capacitors and inductances of large dimensions In addition the rather high value of the decoupling components will exhibit a low pass filter behaviour not compatible with most of the ordinary signals Therefore the isolating device cannot be used in some cases Other coupling isolating methods must be used in these cases The proposed isolating device includes the capacitive coupling in one cabinet The specifications