Home
PanelView Component HMI User Manual
Contents
1. 40 Publication 2711C UM001B EN P September 2008 Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 Change Ethernet Settings You can establish an Ethernet connection between the connected PanelView Component terminal and computer using the Ethernet port or the host USB port on the terminal For the Ethernet port IP addresses can be set dynamically by the network if Dynamic Host Configuration Protocol DHCP is enabled If DHCP is disabled the IP addresses must be entered manually IMPORTANT IMPORTANT Ethernet Settings Parameter MAC ID If a terminal is set for DHCP and is not on a network or is on a network that does not have a DHCP server or the server is not available it will automatically assign itself an Automatic Private IP Address or auto IP address The auto IP address will be in the range of 169 254 0 0 through 169 254 255 255 The terminal makes sure the auto IP address is unique from any other auto IP address of other devices on the network The terminal can now communicate with other devices on the network that have IP addresses in the 169 254 xxx xxx range and a subnet mask of 255 255 0 0 For the USB port use the default IP address that is set when the terminal is connected to the computer This address Is 169 254 254 2 It is not recommended to change this setting Description Read only field that defines the MAC ID of the PanelView Component terminal Each Et
2. Open the system information screen to see the firmware version information for the terminal Refer to View Svstem Information on page 47 for instructions on how to view the current firmware version Insert the storage device into a USB host port or the SD card slot that is on your terminal 3 When prompted to run the Autorun press Yes or the F1 key 14 The splash screen appears and the progress bar indicates a firmware installation is in process Publication 2711C UM001B EN P September 2008 Upgrade Firmware Chapter 5 Publication 2711C UM001B EN P September 2008 IMPORTANT OK is displayed Do not remove the SD card or USB flash drive until upgrade When the firmware installation is complete and successful the progress bar stops with the success code OK 4 Remove the storage device and reboot the terminal 5 Open the system information screen to see the firmware version that is expected after the installation Allen Bradley R Syaa Defoe L i efer to View System Information on page 4 Main Spb Urvhorcesticm Linares Vertinn 01 00 File Mariage ont Code Werthin 00 00 Comm imr Logic Hoard Vertinn 10 Slarlup Applicalion Terminal One Time Ii Display Display Gn Time i Matt ry Statui Mul Available Dale ard Time Syibem Intormalion how to view the current firmware version for instructions on 15 Chapter 5 Upgrade Firmware
3. corre Arywey STGP satan 66 Publication 2711C UM001B EN P September 2008 Cable Connections and Communication Chapter 4 Publication 2711C UM001B EN P September 2008 The software installs Found Hew Hardware Wizard Plaate mai while the wizard inctalle the collware En Alen Bisdiay Panel sw Boot Loader USE Remote HOIS Netvecek Devica 5 Setting a aden restore punt and becky up oki ider m cata pour pelem needs to be rasicosd m the futura 5 Click Finish in the Completing the Found New Hardware Wizard dialog box for the boot loader Found Hew Hardware Wizard Completing the Found New Hardware Wizard The ved har fred installing the voller fon Allen Erades Parelicw Boot Loader USB Remote NDIS Heenk Dec Check Fich bo chore lhe vazand 6 Click Next when the Found New Hardware Wizard dialog box for the PanelView USB Remote NDIS Network Device appears Found Hew Hardware Wizard Welcome to the Found New Hardware Wizard Window wll peach hor cuerent ard updated volvere by locking on your computer on the hadhara melalabon CO of on Ihe Windows Ulpchate Web gabe wath pout penera Can Windows correcl bo W rdows Update bo reanch hor oftware Cea this tne only rez now and even ime connect a device Ho rot ther bane Clack Massel bo corre 67 Chapter4 Cable Connections and Communication 7 Choose Install the software automatically and click next Found Hew Hardwa
4. Reboot the terminal Verify you have good communication to the controller Verify that the communication network cable is connected If new ladder logic is downloading to the controller you could see this message After the download communication should run normally If a remote device not responding alert was present then all external tags being written to will generate this alert Is the address configured in the controller If the address is configured as read only at the controller this address can not be written to Set this external tag as read and remove panel devices from your application that can write data to this external tag Verify you have good communication to the controller Verify that the communication network cable is connected If new ladder logic is downloading to the controller you could see this message After the download communication should run normally If a remote device not responding alert was present then all external tags being read from will generate this alert Is the address configured in the controller If the address is configured as write only at the controller this address can not be read from Set this external tag as write and remove panel devices from your application that can read data from this external tag 79 Chapter6 Troubleshoot the System PanelView Component Terminal Alerts Remote Device S 0 Param1 is Not Responding Category Communication 2
5. 6 Repeat step 5 as the target moves around the screen 7 Tap the screen when prompted to register saved data If you don t tap the screen within 30 seconds the calibration data is lost and the current settings are retained Follow these steps to calibrate the touch screen from the terminal 1 Click Display on the menu list 2 For C600 and C1000 terminals click Calibrate Touchscreen Main File Manager Communication Startup Application Contrast Display Date and Time System Information 3 For C300 touch screen terminals press the right arrow to go to the calibration screen O Allen Bradley PanelView C300 Allen Bradley PanelView C300 O Allen Bradley PanelView C300 Startup Application D __Calibrate Touch Sereen P Display Mco SOE al TY 4 Carefully press and briefly hold stylus on the center of the target Repeat as the target moves around the screen J Ailen Bradisy Fanal View C 1000 fe Al en Bradiey Pana View C300 32 Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 Publication 2711C UM001B EN P September 2008 5 Click OK within 30 seconds once the message appears to accept the changes or the old settings are kept Reboot the Terminal You can restart the terminal without having to disconnect and reapply power After a reset the terminal performs a series of startup tests and then either enters configuration mode or runs the startup applicatio
6. 102 Publication 2711C UM001B EN P September 2008 PanelView Component Emulator Appendix C 7 Click Finish to complete the installation The install complete screen is the final confirmation that the install has completed successfully It should be displayed only after all selected components have completed installation ie PanelView Component Emulator v1 0 Installshield Wizard Completed r yp The Iatabstoekd Wizard has successfully installed Panefitess Component Emulator v1 0 Chek Finish bo awik tha sirang PanelView Component Extended Support This is a Rockwell Automation provided accessory for the PanelView Component emulator This component consists of extended help files sample applications libraries and font files These files were originally installed in the Mapped Share folder Note multiple versions of the PanelView Component emulator could be using the same Mapped Share folder During uninstallation of the PanelView Component Emulator a check is made to see if the Mapped Share folder is being used by any other versions of the emulator If other versions are using the same Mapped Share folder this step is skipped entirely If the PanelView Component Emulator version being uninstalled is the only version using this Mapped Share folder the uninstaller will ask if you want to remove the extended support files If you select Yes the files are deleted and the Mapped Share folder is removed If you select No this
7. 76 Publication 2711C UM001B EN P September 2008 Chapter 6 Troubleshoot the System Chapter Objectives This chapter provides information on how to isolate and correct common operating problems with system components e View system information e Alerts e Troubleshooting View System Information You can view current system information for the connected terminal You should provide this information when contacting technical support e Operating system version e Firmware version e Hardware version number e Status of the battery e Total power on time e Memory used in KBytes Follow these steps to view the system information on your terminal 1 Goto the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the System Information tab 4 View the information 5 Click Apply Alerts The terminal displays alerts at times during operation The alert consists of an ID number and a description Follow the corrective action to resolve the alert Publication 2711C UM001B EN P September 2008 11 Chapter 6 Troubleshoot the System PanelView Component Terminal Alerts Category Communication Communication Communication Communication Communication Communication 78 Lal 3 4 D Data Access Error for Alias S 0 Param2 Controller S 0 Param3 Address is S 0 Param4 Communication Flag is S 0 Param1 The terminal is having trouble reading the external tag a
8. About the Terminals PanelView Component terminals are operator interface devices for monitoring and controlling devices attached to a controller HMI applications are created using a Web application while your computer is connected directly to the terminal You see the direct result on the terminal display without having to download first PanelView Component C200 and C300 Terminals gt PanelView C200 OA Le rr re Fs Fa CO CO E9 ES E9 OB A aolView 6300 View 300 Y 1 Function keys keypad or touch 4 USB device port display 2 24V DC power input i RS 232 serial port 3 RS 422 and RS 485 port 6 USB host port Publication 2711C UM001B EN P September 2008 Chapter 1 Overview PanelView Component C600 and C1000 Terminals UN 10 Fell d f i ME 1 Touch display e USB device port 2 24V DC power input NS 7 Diagnostic status indicators 3 10 100 MBit Ethernet port Replaceable real time clock battery 4 RS 422 or RS 485 port 9 USB host port 5 RS 232 serial port mo Secure digital SD card slot a Analog touch screens are intended for single presses at a time If the touch screen is pressed in two locations at the same time the presses are averaged as a single press in between the two locations How to Connect Browser The terminals can be connected to a browser using either a USB port or an Ethernet network connection Your computer shoul
9. Cannot run an invalid application validation errors save the application and try again 2011 Cannot run a modified application save the application and try again Application has been modified Continue without Edit the application and save prior to performing saving this operation otherwise changes to the application may be lost Edit and validate the application Correct all Publication 2711C UM001B EN P September 2008 Troubleshoot the System Chapter 6 PanelView Component Terminal Alerts Alert 2013 Currently loaded application has been modified All Edit the application and save prior to performing changes will be lost by running this application this operation otherwise changes to the Continue application may be lost Alert 2014 Application was designed for a different terminal Edit the application on the terminal type that It is type and may not appear or operate as intended intended for Continue Alert 2015 Application will be unloaded and deleted Click Yes to continue with operation Continue Alert 2016 Confirm deletion Click Yes to delete the file Alert 2017 Press Yes to restart the terminal Alert 2018 File already exists Overwrite If you do not want to overwrite the file cancel the operation and rename the file before performing this operation Alert 2019 Cannot copy over loaded application Unload Click OK to unload and overwrite the application application and
10. Certifications when Value product is marked c UL us UL Listed Industrial Control Equipment certified for US and Canada See UL File E113724 CE European Union 89 336 EEC EMC Directive compliant with EN 61000 6 2 Industrial Immunity EN 61000 6 4 Industrial Emissions EN 61131 2 Programmable Controllers C Tick Australian Radiocommunications Act compliant with AS NZS CISPR 11 Industrial Emissions 1 See the Product Certification link at http ab com for Declarations of Conformity Certificates and other certification details 93 Appendix A Specifications 94 Publication 2711C UM001B EN P September 2008 Available Fonts Import a Font File Publication 2711C UM001B EN P September 2008 Appendix B Adding Font Files These fonts reside on the terminal in the firmware image e Arial e Courier New e Tahoma e Asian Font Simsun Simplified Chinese You can change the Asian Font firmware image from Chinese to Korean or Korean to Chinese by using the firmware upgrade method described in Chapter 5 The Arial Courier and Tahoma fonts cannot be altered Additional Windows CE licensed fonts can be added to the terminal Windows CE licensed fonts are distributed on the PanelView Component Accessory CD or can be downloaded from the PanelView Component Tech Support website No other fonts are licensed for use on the terminal You can import a Microsoft Windows CE font to your terminal Other font file
11. circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automation Inc is prohibited Throughout this manual when necessary we use notes to make you aware of safety considerations Identifies information about practices or circumstances that can cause an explosion in a hazardous environment which may lead to personal injury or death property damage or economic loss IMPORTANT Identifies information that Is critical for successful application and understanding of the product Identifies information about practices or circumstances that can lead to personal injury or death property damage or economic loss Attentions help you identify a hazard avoid a hazard and recognize the consequence ATTENTION STH a Wan Labels may be on or inside the equipment for example a drive or motor to alert people that dangerous voltage may be present TETY Labels may be on or inside the equipment for example a drive or motor to alert people that Surfaces may reach dangerous temperatures la la La Rockwell Automation Allen Bradley TechConnect PanelView PanelView Component and MicroLogix are trademarks of Rockwell Automation Inc Trademarks not belonging to Rockwell Automation are property of their respective companies Publication 2711C UM001B EN P September 2008 Summary of Changes The information below summarizes t
12. configured with new language An attempt was made to switch to a language that is not configured for this application Publication 2711C UM001B EN P September 2008 Troubleshoot the System Chapter 6 Please reset the terminal or this may lead to fatal error Verify the range of the numeric display that uses the external tag as Its write tag Is within the range of a tag validation should provide a warning if the range of the tag Is greater than the range of a numeric entry Make sure that the values of the State based objects that write to an external tag are within the range of the tag Make sure that the value that written to an external tag matches the tag type for example do not write a non numeric string into a numeric tag Verify the range of the numeric display that uses the external tag as its write tag Is within the range of a tag validation should provide a warning if the range of the tag Is greater than the range of a numeric entry Make sure that the values of the state based objects that write to an external tag are within the range of the tag Make sure that the value that written to an external tag matches the tag type for example do not write a non numeric string into a numeric tag Please reset the terminal or this may lead to fatal error This is a out of memory critical message Dismissing this dialog causes the terminal to reset After the terminal resets try to edit an application and re
13. 2 m 6 56 ft C1000 2711C CBL ABO3 RS 485 5 pin to RJ45 cable C200 C300 C600 C1000 MicroLogix Controller The chart provides a summary of terminal connections to controllers Cable Charts and network interface modules PanelView Component Terminals to MicroLogix Controllers Protocol PanelView MicroLogix 8 pin MicroLogix MicroLogix 1100 MicroLogix 1100 Component Port Mini DIN 1000 9 pin D shell RS485 1763 NC01 Ethernet 1100 1200LSP 1500LRP Ch 1 1500LSP Ch 0 DF RS232 1761 CBL PM02 1747 CP3 N A DH 485 RS232 1761 CBL PM02 1747 CP3 Use AIC module N A 1761 NET AIC connect to port 3 RS4g5 N A N A Belden 3106A or N A 9842 or equivalent Modbus RS232 1761 CBL PM02 1747 CP3 Use AIC module N A 1761 NET AIC connect to port 3 Ethernet Ethernet N A N A N A CAT 5 Ethernet MicroLogix ENI 2 1 RS485 is non isolated and is recommended for connecting to only one device with an isolated port 56 Publication 2711C UM001B EN P September 2008 Cable Connections and Communication Chapter 4 Ethernet Connection The C600 and C1000 terminals have an Ethernet port that supports e communication to a controller e connection to a computer for application design Ethernet Connector The base configured unit of the terminals has an RJ45 10 100 Base T connector for EtherNet network communication Ethernet Connector Pinout Pin Pin Name Looking into RJ45 TD Connector e 1 8 RD Z O Z
14. P September 2008 IMPORTANT Troubleshoot the System Chapter 6 Keyboards initialize at different times If the terminal boots normally to the configuration screen or the selected startup application the keyboard press was not recognized Restart the terminal and wait until the boot screen displays the INIT code N1 then press and hold the Ctrl and Shift keys until the dialog box appears 2 Press Yes or F1 to return to the out of box condition or press No or F2 to cancel If you choose to return to the out of box condition the terminal resets On the subsequent boot the file system is formatted and removes the contents including applications logs recipes user installed fonts objects and graphics Most terminal configuration parameters are returned to their default values IMPORTANT IMPORTANT Returning to the out of box condition does not change the current firmware on your terminal If you upgraded the firmware on your terminal the upgraded firmware version remains unaffected Refer to page 72 for details on what is included in a firmware upgrade If you set the terminal security and forgot your password you can use this procedure to restore your terminal Remember It will remove all applications logs recipes user installed font files objects and graphics 89 Chapter 6 Troubleshoot the System 90 Publication 2711C UM001B EN P September 2008 General Specifications Publication 2711C U
15. Repeat Settings You can configure key repeat settings for the terminal keys or attached keyboard of the connected terminal TIP You cannot change the key repeat settings from the on terminal configuration screens If you want to change this setting you must connect to the terminal through a web browser The repeat rate is the speed at which a character repeats per second when you hold down a key The repeat delay is the amount of time in milliseconds that elapses before a character begins to repeat when you hold down a key Follow these steps to change the repeat settings for keys 1 Goto the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the Display Input tab 4 Check Enable key repeat to enable repeat settings for keys PanelView Component Dashbnard Fle Transter Help Sign aii Display eit System information Communication Terminal Security Ls plane Inpart Devicen Brvahiness 100 C Enable tery repeal QA 2 Key Repent Rala Contrast 5 3 Fey Repeat Cieli Sneen aawer mode i i i A ee ws y Enable Sorgen Sever and Derr Asbo Teme Seeon saver timeni i O Caine Touch Scieen Mine i Beren saver brighiness E aua A 5 Drag the slider under Key Repeat Rate to adjust the speed at which a character repeats when a key is held down 6 Drag the slider under Key Repeat Delay to set the amount of time that elapses before a character begin
16. Startup Applicabion inite THOC Terminal Language Emptesh ll Emen Pomuguds Frangaia ma ana Deusen Espa ol Mb COL Current D Morin Day Year August 27 m 2009 Cuenent Tine Hour Minaie Second la i 33 6 Ob w Automatica y adjust for daghi savings ime Tires Zone GMT 00 00 Pacs Time US 4 Canada rs AN 47 Chapter 2 Configuration Mode 48 Follow these steps to view system information using the C200 or C300 PanelView Component terminal 1 Select System Information from the menu list and press enter Allen Bradley PanelView C300 Screen Saver b System Information Reset Terminal The system information appears 2 Press F3 to see more information press F2 to go back or press F4 to exit to the main menu Allen Bradley PanelView C300 Allen Bradley PanelView C300 Allen Bradley PanelView C300 Allen Bradley PanelView C300 Systern Information Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 Publication 2711C UM001B EN P September 2008 Follow these steps to view system information using the C600 or C1000 PanelView Component terminal 1 Click System Information from the menu list The system information screen displays firmware version boot code version logic board version terminal on time display on time and battery status Main File Manager Communication Startup Application Display Date a
17. Z Y olojo Shield Connection Chassis Gnd a O Either a standard Ethernet cable or a crossover cables such as 2711P CBL EX04 can be used when connecting directly to a logic controller or switch Cables The PanelView Component terminals require category 5 twisted pair cables The maximum cable length between the terminal s Ethernet port and a 10 100 Base T port on an Ethernet hub without repeaters or fiber is 100 m 328 ft In industrial applications keep the cable length to a minimum For additional information refer to the EtherNet IP Media Planning and Installation Manual publication ENET INOO1 Publication 2711C UM001B EN P September 2008 57 Chapter 4 58 Cable Connections and Communication Security Considerations IGMP Internet Group Management Protocol is used for IPv4 multicast A multicast is communication between a single sender and multiple receivers on a network IGMP is used to exchange membership status data between IPv4 routers that support multicasting and members of multicast groups A router is an intermediary device on a communication network that expedites message delivery by finding the most efficient route for a message packet within a network or by routing packets from one sub network to another A sub network is a separate part of an organization s network identified through IP addressing PanelView Component terminals provide level 2 full support for IPv4 multicasting GMP ver
18. and controlled by the application running on the terminal The table shows indicator states if the terminal stops during startup Fault Indicator States During Startup Comm Recommended Action Green Indicator State Fault Red Indicator State Description Potentially recoverable errors Blinking Off Last firmware download Reload the firmware failed Blinking Blinking EBC boot loader Reload the firmware firmware failed or is missing Blinking On Windows CE OS Reload the firmware firmware failed or is missing Nonrecoverable or fatal errors On Off Fatal hardware error Replace the terminal On Blinking Fatal display hardware Replace the terminal error You may want to return a terminal to the out of box condition to refresh the terminal or to recover from severe application misbehavior There is a special maintenance action that permits you to perform a complete reset and return to the out of box condition for the terminal Returning a terminal to an out of box condition does not affect the terminal firmware version or the installed font image Follow these steps to return your terminal to the out of box condition 1 Connect an external USB keyboard to the terminal and hold the Ctrl and Shift keys simultaneously while starting up the terminal A dialog box appears with the prompt Return to Out of Box Condition Publication 2711C UM001B EN P September 2008 Publication 2711C UM001B EN
19. be familiar with standard panel installation techniques For additional information on the PanelView Component terminals refer to these publications that you can download from http literature rockwellautomation com Resource Description PanelView Component Terminal Installation Provides instructions for installing a Instructions publication 2711C IN001 PanelView Component terminal PanelView Component Operator Terminals Provides instructions on setting up a sample Quick Start publication 2711C QS001 application on a PanelView Component terminal If you would like a manual you can e download a free electronic version from the Internet at http literature rockwellautomation com e purchase a printed manual by contacting your local Allen Bradley distributor or Rockwell Automation sales office Publication 2711C UM001B EN P September 2008 7 Preface Preface Firmware Upgrades To receive firmware upgrades and other downloads for your PanelView Component terminal e call your local Rockwell Automation sales office or distributor e access http ab com eoi graphicterminals panelviewcomponent html 8 Publication 2711C UM001B EN P September 2008 Chapter 1 Overview Chapter Objectives This chapter gives an overview of the PanelView component terminals e About the terminals e How to connect browser e PanelView Explorer e How to display help e Peripheral connection e Catalog number configuration
20. step is skipped and the files and directory remain Publication 2711C UM001B EN P September 2008 103 Appendix C PanelView Component Emulator 104 al Local Area Connection m lips General Advanced Errors During Installation If an error is reported while configuring the Loopback Adapter make sure the Loopback Adapter settings are correct Follow these steps to configure the Loopback Adapter settings 1 Open the Windows Network Connections folder and right click the connection with device name Microsoft Loopback Adapter Type Status Device Name LAN or High Speed Internet LAN or High Speed Internet Connected Broadcom Netxtreme S xx Gigabit Controller LAN or High Speed Internet Connected Microsoft Loopback Adapter wireless Network Connection LAN or High Speed Internet Disabled Call Wireless 1390 WLAN Min Card wh 1394 Connection LAN or High Speed Internet Disabled 1394 Net Adapter 2 Select Properties 3 Make sure the Internet Protocol TCP IP box is checked highlight Internet Protocol TCP IP and select Properties Local Area Connection 40 Properties Connect using B Microsoft Loopback Adapter The conmecton uses the followsng tems M4 JE Fie and Printer Sharing for Microsoft Networks Pass Protocol IEEE S02 1x v3 4 9 0 Internet Protocol TCP IP hor gt Install Uruncta Properties Description Transmission Control Protocol Intemet Protocol The defa
21. the media in the terminal External media can be a USB flash drive or an SD memory card Terminal Users Copy the help files to the WebHelp folder off the root directory of the SD memory card or USB flash drive into a folder named WebHelp Emulator Users Copy the help files to the WebHelp folder in the shared directory of the emulator for example C Documents and Settings All Users Shared Documents Allen BradleyYPVe Emulator WebHelp View Help Files After copying the help files to external media and inserting the media in the terminal you can view the help files by closing this help window and clicking the help button again TIP When receiving updated help files you may have to clear cache in your browser before the new help files display To clear cache in the Firefox browser select Tools gt Clear Private Data Verify the Cache checkbox is checked and click the Clear Private data button To clear cache in the Internet Explorer browser select Tools gt Internet Options On the General tab click the Delete button under Temporary Internet Files to delete all temporary internet files including offline content Publication 2711C UM001B EN P September 2008 Overview Chapter 1 Peripheral Connection PanelView Component terminals have a USB host port You can power USB peripherals directly from the PanelView Component terminal If the USB peripheral is not powered directly from the PanelView USB port either e inst
22. timeout T Calbrabe auch Screen Trung L SEAN Saver brighiness Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 Follow these steps to change the display brightness or contrast from the terminal 1 Click Display on the menu list C200 C300 C600 C1000 D Allen Bradley PanelView C200 Main PE Current Application UA File Manager Startup Application 4 v b Goto P Display wW a dl Communication Configuration Language 3 j Startup Application Portugu s a Fran ais Display Italiano Deutsch Espa ol fal CP 32 System Information Reset Terminal Date and Time 2 Use the arrow keys to adjust the brightness or contrast up or down On the C200 and C300 terminals press F3 to go to the contrast adjustment screen The change takes effect immediately TIP The C1000 has only a brightness control C200 C300 Brightness D Alfen Bradiley PanelView C200 C600 Brightness and Contrast Main File Manager Communication Startup Application gt Alen Eradioy Pane lView C200 Display Date and Time System Information Publication 2711C UM001B EN P September 2008 25 Chapter 2 26 Configuration Mode Configure the Screen Saver You can enable or disable the screen saver on the connected PanelView Component terminal The terminal has four screen saver modes screen saver dimmer screen saver and dimmer or disable e Screen saver activates afte
23. 00 and C300 38 change startup application C600 and C1000 37 date and time C600 and C1000 40 Ethernet settings C600 and C1000 43 interface 18 language 22 language C200 and C300 23 language C600 and C1000 23 reboot terminal C200 and C300 35 reboot terminal C600 and C1000 34 screen saver C200 and C300 28 screen saver C600 and C1000 27 security 44 security PanelView explorer window 45 system information C200 and C300 48 system information C600 and C1000 49 terminal settings 20 brightness and contrast 24 calibrate touch screen 31 change startup application 36 date and time 39 enable terminal security 44 Ethernet 41 key repeat 30 Publication 2711C UM001B EN P September 2008 Index on PanelView explorer startup window 21 on terminal 20 reboot terminal 33 screen saver 26 system information 47 terminal language 22 transfer applications 50 user defined objects 52 troubleshooting 7 7 86 alerts 77 check for power 86 status indicators 87 U update firmware on nonoperating terminal 118 USB device port 61 flash drive 53 host port 60 install driver 61 ports 11 user defined objects 52 W wiring and safety guidelines 55 125 Index 126 Publication 2711C UM001B EN P September 2008 Rockwell Automation Rockwell Automation provides technical information on the Web to assist you in using its products At http support rockwellautomation com you can Support find technical manuals a knowledge base of FAQ
24. 2008 101 AppendixC PanelView Component Emulator 6 Click Install to continue with the installation cancel to cancel the process or back to make changes to your installation The verification screen gives you a chance to cancel the installation process before any permanent changes occur ie PanelView Component Emulator v1 0 Ready to Install the Program The wizard ls ready bo begir irecdtallaytion Ok Install to begin the instalation f you want bo revisa or change any of your inetallation csttimoa cick Back Click Canal to azk the wizard Several software components are required for the Paneles Component Emulator including packages from Mierssoft You yl be prompted bo begin the instalation of aach peage and then returned Lo the Panels Component Emulator wizard The installgbon process wall Lake several minutes to complete The progress screen gives you a visual indication of the installation progress Maa Ine Microsoft Device Emulator and Microsoft Virtual PC have their own installation procedure and agreements Once they are installed if you selected complete install or selected them for custom install you will be brought back to the finish dialog ie PanelView Component Emulator v1 0 Installing PanelView Component Emulator vi 0 The program Features you selected are beira installed z Please aak sida the IrstalShield WE sd netals Panels Component Emate viO The may take several miuta SEa AAA
25. 22 RS 485 Connector Pinout Pin Signal 1 T 2 T 3 R 4 R D S Shield The RS422 485 port has integrated 121 ohm termination between the R and R signal pair This value is compatible with RS422 and RS485 electrical specifications Additional termination on the PanelView Component end of communication cables is not required The terminals have a USB device and USB host port USB Host Port You can power USB peripherals directly from the PanelView component terminal If the USB peripheral is not powered directly from the PanelView USB port either e install the USB peripheral in the same enclosure as the PanelView terminal and make sure it is connected to the same ground system e connect to the USB peripheral through a galvanically isolated hub You can use the USB host port to connect a USB Flash drive to transfer application files fonts and images some USB flash drives might not be compatible with the PanelView Component terminal and might not support file transfers or firmware upgrades The 2711C RCSD memory card is tested with the PanelView Component terminal to ensure compatibility Publication 2711C UM001B EN P September 2008 Cable Connections and Communication Chapter 4 ATTENTION Removing the USB flash drive or SD card from the PanelView Component terminal while a firmware upgrade is in process could corrupt the firmware and make the terminal unusable Take precautions to prevent the USB fl
26. 4 2008 2 49AM Fies Currently on the CD wo The installer extracts and runs an Install Shield Wizard Installshield Wizard eg 9 Panelview USB ANDIS Driver Setup is preparing the InstallShield kd Wizard which val guide you through the program sebup process Please wait Extracting Panalview USB RMDIS Dirrer me TILL 3 Click Next when the Welcome dialog box appears ib Panel iew USU RNOIS Dries Welcome to the Installshield Wizard for PanelVview LE RNOES Driver The TrechalGhield Rt Wirard well install Paris LSD NEVES Ceres on your computer To contie chek hert WARNING The progr m g protected by copyright law and international beahes 4 Click Install to begin the installation of the PanelView USB RNDIS Driver ie Pare Wie USL RNOIS Driver Ready to Install the Program The wizard le ready bo begin instalation ick Install Lo begin tha netalan TF you nt ba rawis or change any of your installation settings click Back Click Cantal bo ext the wizard Publication 2711C UM001B EN P September 2008 Cable Connections and Communication Chapter 4 The progress indicator shows that the driver is installing 18 FanelView USU RAD Ss Driver Installing Pane Wire USN AADIS Derive The program features you selected are being incraled alai Picasa mal vids the Iretalhield Wizard natak Panelfier USD RNDIS Driver Thh may bake Sawari minitas Tah 5 Click Next when the Device Driver Installati
27. 7 Communication Invalid Data Address S 0 Param1 Bad address in block S 0 Param1 to S 0 Param2 on device S 0 Param3 Communication 30 Recipe Recipe 1002 Recipe save failed Cause Recipe in Table has not been modified Recipe 1003 Recipe save had errors Recipe 1004 Recipe save completed successfully Recipe 1005 Recipe download failed Cause Operation cancelled Recipe 1006 Recipe download started Recipe 1007 Recipe download completed with errors Recipe 1008 Recipe download completed successfully 80 1001 Recipe upload started Verify all network connections are correct Verify that the communication network cable is connected If new ladder logic is downloading to the controller you could see this message After the download communication should run normally Verify that the network address of the controller matches the terminal controller address configured in the Communication tab In the Communication tab verify that the protocol specifications are correct such as communication rate data bits stop bits These are all protocol specific This Is not syntactically a valid address This can occur when a write only address for a controller has been set for read write in the external tag of the terminal Param1 to Param2 specifies the address block having the Issue somewhere within the range is where the write only address is defined in a PanelView external tag
28. Appendix PanelView Component Emulator Directory Layout and Content 108 This section describes where you can find the files that the installer loaded on your computer Device Emulator Component The directory layout for the Device Emulator is defined by the Microsoft installer for this component No additional actions are required by the PanelView Component Emulator Installer The only emulator main menu item you may need to use is Flash Save Select Flash Save to preserve settings for the next time the emulator is started such as after copying fonts or User Defined Objects into the emulator The other menu items on the main menu do not apply to the PanelView Component emulator A PC Ke metor i fx Flash Save Virtual PC Component The directory layout for the Virtual PC is defined by the Microsoft installer for this component No additional actions are required by the PanelView Component Emulator Installer Publication 2711C UM001B EN P September 2008 PanelView Component Emulator Appendix C Publication 2711C UM001B EN P September 2008 PanelView Component Emulator Component The root install location for the PanelView Component Emulator component is C Program Files Allen Bradley The directory structure under the root location is shown Root Location Directory Structure zj d Phy Computer 2 H 3 4 Floppy 4 e Main Drive C E E Program Files E Adobe 3 1 Allen Bradley 2 PanelV
29. Attribute Real time clock C200 and C300 C600 and C1000 Input voltage range Power consumption max C200 and C300 C600 C1000 Weight approx C200 function key C200 keypad C300 keypad C300 touch C600 touch C1000 touch Dimensions HxWxD approx C200 function key C300 touch C200 keypad C300 keypad C600 touch C1000 touch Attribute Temperature operating Temperature nonoperating Heat dissipation C200 and C300 C600 C1000 Relative humidity shock operating shock nonoperating Vibration Enclosure type ratings 1 Catalog numbers 2711C T6M and Value No battery backup Battery backup 18 30V DC 24V DC nom 5 W 0 21 A at 24V DC 10 W 0 42 A at 24V DC 18 W 0 75 A at 24V DC 0 19 kg 0 40 Ib 0 30 kg 0 65 Ib 0 20 kg 0 43 Ib 0 68 kg 1 48 Ib 1 57 kg 3 41 Ib 80 x 116 x 54 mm 3 15 x 4 54 x 2 13 in 80 x 116 x 57 mm 3 15 x 4 54 x 2 23 in 119 x 139 x 55 mm 4 69 x 5 47 x 2 15 in 154 x 209 x 57 mm 6 0 x 8 23 x 2 25 in 250 x 308 x 54 mm 9 84 x 12 13 x 2 13 in Value On C132 2 122 eE 25 70 C 13 158 F 16 BTU hr 32 BTU hr 58 BIU hr 0 95 noncondensing 15 g at 11 ms 30 g at 11 ms 2 g at 10 500 Hz NEMA UL Type 4X indoor 12 13 and IEC IP54 IP65 2711C T6C do not have NEMA 4X IP65 Type rating Publication 2711C UM001B EN P September 2008 Certifications Publication 2711C UM001B EN P September 2008 Specifications Appendix A
30. BOOTME rex ests on port 980 The utility is waiting for an update request from the terminal 121 Appendix D Firmware Update Utility 6 Reset the terminal Momentarily open the USB connection at the same time power is cycled Otherwise the power from the USB connection may prevent the terminal from resetting 7 Wait until you see Update Complete on the progress bar 8 The terminal reboots and automatically performs the requested operations during startup 9 Check that the terminal reverts to the startup application Softwa re Maintenance You can display the version information of the PanelView Component Firmware Update utility by clicking the About tab Use the Add or Remove Programs tool in the Control Panel of your computer to install a newer version or repair an existing installation of the PanelView Component Firmware Update utility 122 Publication 2711C UM001B EN P September 2008 A about the terminals 9 access configuration mode 15 adding fonts 95 additional resources alerts applications export b1 import 52 transfer 50 applications and files 50 available fonts 95 battery replacement 54 brightness and contrast 24 on terminal 25 PanelView Explorer window 24 C cables charts 56 connections 55 Ethernet 57 calibrate touch screen 31 PanelView explorer window 31 terminal 32 catalog number configuration 13 change startup application 36 C200 and C300 38 C600 and C1000 37 P
31. C UM001B EN P September 2008 117 Appendix D Firmware Update Utility Update Firmware 118 TA Panel iew Component Firmware Update Utility Contirm Installation The installer is ready to install Panelyiew Component Firmware Update Utility on pour computer Click Nest to start the installation Cancel lt Back 4 Click Next to start the installation ie Panel iew Component Firmware Update Utility Installation Complete Panelview Component Firmware Update Utility has been successfully installed Click Close to exit Please use Windows Update to check for any critical updates to the NET Framework Cancel 5 Click Close when the installation is complete This section shows how to update the firmware image on a nonoperating terminal Follow these steps to update the firmware image on the terminal 1 Connect the USB host port of your computer to the USB device port on the terminal 2 From the Start Menu select Programs gt Allen Bradley gt PanelView Component Firmware Update Utility Publication 2711C UM001B EN P September 2008 Firmware Update Utility Appendix D 3 When the utility is running make sure Update Firmware is checked Es Maintenance Utilities Begin waiting for Afte Maa if AS armo fy Sees HIT connect requests 7 il EJ C Temp S 01 01 002 IMG Browse 4 Click the Browse Button to select an SC image for example SC 01 01 002 IMG The
32. Chapter 6 Firmware Installation and Loading Message State Code Load Firmware Image into RAM 1E Write Firmware Image into Flash A5 Complete and Successful Firmware Installation OK Firmware Image Validation CRC Format Failure 1E Firmware Image Compatibility Failure 1F Firmware Write to Flash error A5 Firmware Read After Write Verify D2 Invalid or missing Firmware Image 0A Other Commonly Observed Status Codes Message State Code Boot Loader connects to PC via USB Device DA Boot Loader loads Firmware Image into RAM E6 Boot Loader jumps to Operating System FF Operating System start up GO Operating System Initialize 1 JO Application Registration and Initialize N1 N3 Application Load and Execute N4 N6 POST errors are fatal and most likely due to failed hardware A fatal error during firmware installation and loading is most likely recoverable by installing the appropriate firmware Interpret the Status Indicators at Startup The C600 and C1000 terminals have indicators on the back of the unit to isolate operating problems e Comm indicator for communication e Fault indicator for hardware faults Publication 2711C UM001B EN P September 2008 87 Chapter6 Troubleshoot the System Returning to the Out of box Condition At startup the Fault indicator is off except for a few brief flashes and the Comm indicator is on If the indicators remain off check the power cable After a successful startup both indicators are off
33. Codes There are a variety of failure conditions that can occur in the emulator browser launch process The launch mechanism contains a popup dialog to report errors to the user To avoid multi language issues the error reporting dialog simply contains a title bar and up to three pieces of error detail information The first piece of this error detail information is required This is the error code The remaining two pieces are optional and their content varies according to the error code PVcEmClick Error Codes 0x10001 0 lt emdargs gt Invalid command line 0x10002 Missing CHA file name path command argument 1 lt name path gt CHA file name path argument ends in al r ee CHA file name path does not contain path info 0x10003 0 lt keyname gt Emulator info not found registry 0x10005 0 f lt errcode gt Error reading CHA file header 1 lt chaparam gt Invalid CHA file header content 0x1000A hh Failed calling launch script PVcEmLaunch Error Codes 0x20001 0 lt emdargs gt Invalid command line 0x20003 0 lt keymames Emulator root not found registry 1 lt keyname gt No matching emulator version found in registry lt version gt Best fit invalid version number format lt err code gt Best fit failed enumerating installed versions Best fit no best fit found 0x20006 gt No TitleBar found in emulator skin XML file 0x20004 0x20007 MN The emulator is already running 0x20008 lt err code gt Unab
34. Day Year Boot Gode version TEE pers az iat soce Logie Board version IS nina Qu Bathory sists Good Hour Minule Sucumd Torminal on Eme minutna s250 S IE S e Momary usad 1 ec DO automatically adjust for daylight savings lima a Time zone AI GMT 08 00 Pacific Tire US amp Canada Inetiel_ THO e Terminal Language English mx is ETSEN Enalish Ponugu s Fran ais itahano Deutsch Espa ol Mire o 30 5 Click Apply or click Cancel to restore the current setting Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 Publication 2711C UM001B EN P september 2008 Follow these steps to select or change the startup application from the C600 or C1000 terminal 1 Click Startup Application from the Main menu lain Current Application File Manager Soto Communication Configuration Language nglish Startup Application Portuqu s Francais Display Italiano Deutsch Espa ol fal Pe System Information Reset Terminal Date and Time 2 Click Change Startup Application under Startup Application startup Application File Manager Communication Startup Sap aan Change Startup Application Display Dale and Tire Sysalem informaton This displays the File Manager screen 3 Select the location of the application from the Source list either Internal USB or SD File Manager File Manager Communication Startup Application Displ
35. M001B EN P September 2008 Specifications Appendix A PanelView Component 2711C F2M 2711C K2M 2711C T3M 2711C K3M Attribute Display type C200 C300 C600 C1000 Display size C200 C300 C600 C1000 Display area C200 C300 C600 C1000 Resolution pixels C200 C300 C600 C1000 Backlight C200 C300 C600 and C1000 Operator input C200 C300 C600 and C1000 Memory card C200 and C300 C600 and C1000 Programming port Battery life 2711C T6M 2711C T6C 2711C T10C Value Monochrome transflective STN passive matrix Monochrome transflective FSTN passive matrix Monochrome transmissive FSTN passive matrix or Color transmissive CSTN passive matrix Color transmissive TFT active matrix LCD 2 In 3 in 5 7 in 10 4 in 49 x 14 mm 1 93 x 0 55 in 67 x 33 mm 2 64 x 1 30 in 115 x 86 mm 4 53 x 3 39 in 211 x 158 mm 8 31 x 6 22 in 122 x 32 128 x 64 320 x 240 640 x 480 50 000 hours life min backlight not replaceable Yellow Green status indicator White status indicator CCFL Function keys or combination function keys and numeric keypad Analog touch or combination function keys and numeric keypad Analog touch USB port USB port and Secure digital SD card USB device port 5 years min at 25 C 77 F 91 Appendix A Specifications Environmental 92 PanelView Component 2711C F2M 2711C K2M 2711C T3M 2711C K3M 2711C T6M 2711C T6C 2711C T10C
36. N P September 2008 PanelView Component Emulator Appendix C Using the Emulator Publication 2711C UM001B EN P September 2008 Windows Start Menu The PanelView Component emulator installer creates entries in the Windows Start Menu that can be used to launch a specific emulated terminal type There is also a shortcut named Applications which is simply a shortcut to the Mapped Share folder The shortcuts are installed for all users g Uindock Compuber a ret Deri Windows XP Professional The emulator lets you create applications without being connected to a terminal By default anytime you create save an application on emulator it goes to the mapped share folder When using the emulator to create or change applications TIP make sure your pop up blocker Is off Anything you pull into internal storage on the emulator fonts graphics has to be Flash Saved for it to be permanently stored in emulator Otherwise it s lost once you shut down To save to internal storage select Flash and then Save from the Emulator s main window menu On the emulator do not change terminal communication settings otherwise you need to uninstall and install the emulator and the data will be lost Follow defaults when installing the emulator it sets up the file structure TIP For more information on working with the emulator refer to the context sensitive help 111 Appendix PanelView Component Emulator Error
37. PanelView Component HMI Terminals User Manual Catalog Numbers 2711C F2M 2711C K2M 2711C T3M 2711C K3M 2711C T6M 2111G T6C 2711C T10C Rockwell ALLEN BRADLEY e ROCKWELL SOFTWARE Automation Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment Safety Guidelines for the Application Installation and Maintenance of Solid State Controls publication SGI 1 1 available from your local Rockwell Automation sales office or online at http literature rockwellautomation com describes some important differences between solid state equipment and hard wired electromechanical devices Because of this difference and also because of the wide variety of uses for solid state equipment all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable In no event will Rockwell Automation Inc be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment The examples and diagrams in this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to use of information
38. PanelView USB Remote NDIS Network Device Found Hew Hardware Wizard Completing the Found New Hardware Wizard The vazand har reed ritaling the toallas los Allen Bade Panehiew USE Heroles HOIS Meteo Denta Check Fruch bo chore lhe vazand 69 Chapter 4 Cable Connections and Communication 70 Publication 2711C UM001B EN P September 2008 Chapter 5 Upgrade Firmware Chapter Objectives This chapter provides topics on how to upgrade firmware in the terminal e Prepare for firmware upgrade e Upgrade firmware using a removable storage device The firmware upgrade runs an executable script on a removable storage device such as a USB flash drive or an SD card that copies a firmware image into the flash memory of the terminal Prepare for Firmware Follow these steps before a firmware upgrade is started Upgrade i Backup applications and library objects from the terminal 2 Click Stop the stop sign shown when an application is loaded and in Edit Test Run mode to unload the currently loaded application PanelView Component Tarmi Foie fae raar Hip Sian Lal stop Button Situs Comectad to Tiamina a Pio meet English Foragu s Frames Raiano Deutsch Espa ol Mie UA To stop an application from the terminal go to the main configuration screen and reset the terminal and then reboot If you have not saved changes to the application you are prompted to do so Once the applicati
39. Recipe restore failed Cause Operation cancelled This message is for informational purposes No corrective action needed Recipe 1013 The status data point for Recipe S 0 Param1 Check for operation could not be written to Data Point S 0 Param2 Communication errors Bad status data point specification The status value written is outside the Low EU and High EU limits of the numeric data point assigned These are optional OPC defined properties representing data point minimum and maximum values The status value could not be converted to the type of the data point assigned Recipe 1014 Recipe download failed Cause The value S 0 Correct the dataset value Param1 is less than the minimum value S 0 Param2 allowed for ingredient S 0 Param3 Recipe 1015 Recipe S 0 Param1 failed Cause No Selector Add a recipe selector device to the screen on display Recipe 1016 Recipe S 0 Param1 failed Cause No DataSet Add a dataset selector device to the screen Selector on display Recipe 1017 Recipe S 0 Param1 failed Cause No Table on Add a Recipe Table Panel device to the Screen display Recipe 1018 Recipe S 0 Param1 operation was not started Wait for a recipe operation to complete before because the system Is currently busy performing Starting the next recipe operation another Recipe operation Recipe 1019 Recipe S 0 Param1 failed Cause No recipe select recipe and t
40. SC image is typically obtained from the PanelView Component technical support website When a valid SC image is opened the version information is extracted and displayed 5 Click the Begin Waiting for Connect Requests button to start the firmware update The utility is waiting for an update request from the terminal 6 Reset the terminal Momentarily open the USB connection at the same time power is cycled Otherwise the power from the USB connection may prevent the terminal from resetting Publication 2711C UM001B EN P September 2008 119 Appendix D 120 Firmware Update Utility 7 Observe the progress bar and the Details window for status information as the images are downloaded to the terminal While the image is downloading the terminal displays UPDATE 1E on its splash screen 8 Wait until you see Update Complete on the progress bar E aime fags 0 IP 169 254 254 2 port 0 sring S IMG file C Femp S 01 01 082 1MG alent manifest length 162 9 Wait for the terminal to write the new image to flash memory During this operation the terminal displays UPDATE A5 on the splash screen After about one minute the terminal displays Update Complete The terminal reboots itself when the new image is successfully written to flash memory 10 Observe the firmware version information of the new image The firmware version is displayed on the startup screen and will also appear on the S
41. View C200 Main i 4 Current Application Curent Appicalion ie File Manager Communication Configuration Language nglish Startup Application Portuqu s Francais Display Italiano Deutsch Espa ol Epi System Information Reset Terminal Goto Allen Bradley PanelView C300 Date and Time Publication 2711C UM001B EN P September 2008 17 Chapter 2 Configuration Mode Configuration Interfaces C200 Function Keys T Aen Bradley PanelView C200 h le Conf poe O ww Fr Fe Fa Fa a C200 Function and Numeric Keys D Allen Bradley PanelView C200 P Config Language Current Application 18 Terminal settings can be configured either on the terminal or through a web browser using the PanelView Explorer Startup window Terminal Interface The on terminal interface lets you make changes to the terminal configuration On the C200 and C300 terminals you have to use the arrows to scroll through the menu The C600 and C1000 terminals have the menu displayed on the left side of the terminal screen C300 Touch Screen dile Brady Panai Vine C300 Config Language File Manager Current Application C300 Function and Numeric Keys Allen Bradley PanelView C300 b Config Language File Manager Current Application C600 C1000 Touch Screen Main File Manager Communication Startup Application Display Date and Time System Information Current Applica
42. adidas tet ieee ea hw Terminal Senos raras Pohod we eee en eee x Managing Applications and Files 005 Transferring Applications 13 64 44 doors oeste dd Transferring User defined Objects o ooo o Chapter 3 Chapter OD ECVE A ae ere as Oa ered Ae eee SD Memory Card 2 o0du se tds dia ada dias USB asa DAS ona da ee ae eee den al Battery Replacements jaca le pad le ajeno la ls dE Chapter 4 Chapter ODECE aa 0 tam oe be mee baer he inn E Wiring and Safety Guidelines strains eens wees CONNECTING DEVICES 2 ad r eG ah bk ed ld a MicroLogix Controller Cable Charts Pineere t CONNCGIONs 43 44 440442442065 446 BSG ES ad Sena CONS CHO NS a o Re Be BS USB POMS yu as ai di Be oka de amp Chapter 5 Chapter ODEVE S 4 20 iso dee arde ina Prepare for Firmware Upgrade o o ooo o Firmware Installation Using Removable Storage Device Publication 2711C UM001B EN P September 2008 Table of Contents Troubleshoot the System Specifications Adding Font Files PanelView Component Emulator Firmware Update Utility Index Chapter 6 Chapter Die ONES crad ea ee ea El I7 View Systemi TAIOrmaAtON siega e A ea od J7 A E E E E EE EEE E EEE EEE EE EET a7 TOUDE KOGUN opio aia 86 Returning to the Out of box Condition 88 Appendix A General SpeCINCANONS icon 91 Pavitonmental asentado ondas 92 Conicyt ds es seais EE 93 Appendix B AVA DIE Pombo dado oda R
43. al or emulator Ethernet network and USB connections are supported for connection to a physical terminal For the emulator the emulator and browser must be on the same computer Supported Browsers and Platforms Operating System Browser Platform Supported Windows Vista Internet Explorer 7 Firefox 2 Terminal and emulator Windows XP SP2 Internet Explorer 7 Firefox 2 Terminal and emulator Windows 2000 SP4 using Ethernet network Internet Explorer 7 Firefox 2 C600 and C1000 Terminal using Ethernet connection only 16 Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 If you use a browser other than a recommended browser this message appears AB PanelView Component ORAL Terminal Settings File Transfer Help Sign Off IS Foran improved experience while using thie application itis Name initial 110 recommended that you use Location Internal A a hi 17 0 or higher or Mode Running a Mocilla s Firei Intial_Tioc O Do notask me again OF Torminal PanelView C600 Color Slalus Conmected to Terminal vie Elbe nel edit tet Run New Application Create amp Edil English Portugu s Fran ais Malano Deutsch Espa ol IFT T0 Runtime Configuration The runtime configuration is when you make changes on the actual terminal Changes can be made whether an application is running or not running C200 C600 and C1000 E Allen Bradley Panel
44. all the USB peripheral in the same enclosure as the PanelView terminal and make sure it is connected to the same ground system e connect to the USB peripheral through a galvanically isolated hub Removing the USB flash drive or SD card from the PanelView Component terminal while a firmware upgrade is in process could corrupt the firmware and make the terminal unusable Take precautions to prevent the USB flash drive or SD card from being accidentally disconnected Also do not power off the terminal while a firmware upgrade is in progress USB hubs can produce unexpected behaviors and as a result are not recommended Catalog Number These are the available PanelView Component terminals Configuration 2711C F2M_ C200 Function Function keys Monochrome rear em keys 2711C I3M C300 Touch screen screen ma ee keys 2711C T6M C600 Touch screen Monochrome Publication 2711C UM001B EN P September 2008 13 Chapter 1 Overview 14 Publication 2711C UM001B EN P September 2008 Chapter 2 Configuration Mode Chapter Objectives This chapter covers topics that show how to use the Configuration mode of your PanelView component terminal e Configuration mode e Configuration interfaces e Terminal settings e Managing applications and files e Transferring applications e Transferring user defined objects Configuration Mode The terminal can be configured from either the design time or the runtime user
45. anelView explorer window 36 clean file system 121 clean registry 121 computer requirements 10 configuration interfaces 18 PanelView explorer startup window 19 terminal 18 configuration mode 15 access 15 design time 16 runtime 17 connect a browser 10 Ethernet 11 USB ports 11 connect devices 56 Publication 2711C UM001B EN P September 2008 Index D date and time 39 C600 and C1000 40 PanelView explorer window 39 design time 16 operating systems 16 Supported browsers 16 display help 12 E emulator 99 custom setup 101 directory layout and content 108 emulator use 111 error codes 112 initial splash screen 100 install complete 103 installation 99 installation errors 104 installation type 101 launch mechanism 110 launch windows start menu 111 license agreement 100 mapped share folder 110 overview 99 progress screen 102 uninstall 106 uninstall extended support 103 verity install 102 enable terminal security 44 Ethernet 11 cables 5 change settings 41 connector 9 PanelView explorer window 42 security considerations 58 settings C600 and C1000 43 export applications 51 F firmware install from storage device 74 prepare for upgrade 71 prepare storage device 74 upgrade 71 upgrades 8 using removable storage device 72 123 Index 124 fonts adding 95 available 95 import 95 remove 96 H how to connect a browser 10 display help 12 IGMP Protocol 58 import applications 52 import font 95 ins
46. ash drive or SD card from being accidentally disconnected Also do not power off the terminal while a firmware upgrade is in progress EA A USB hubs can produce unexpected behaviors and as a result are not recommended USB Device Port You must connect the PanelView USB device port to a USB host that is connected to the same ground system This port can be used for connecting to a computer to transfer applications fonts and images IMPORTANT Before connecting your computer to the USB port of the PanelView Component terminal you must first install the Allen Bradley PanelView USB remote NDIS Network Device driver on your computer IMPORTANT The USB RNDIS driver is only supported on Windows XP and Windows Vista operating systems It is not supported by the Windows 2000 operating system Install the USB Driver Follow these steps to install the USB driver on your computer 1 Browse the Accessory CD and open the USB Driver folder IEIZ A Hame Date bodhied Files Currently on the CD Publication 2711C UM001B EN P September 2008 61 Chapter 4 Cable Connections and Communication 62 2 Run the installer Panel View Component USB Driver exe amp DUSE Driver Ele Edi New Favorites Took Hep ua BP sewch D Fods Fe Adrien ie amp se fener A eme Sue Type Date Mode OD Writing Tasks E Files Currently on the CD Y Write these fies to ED BB eve ust Orvar exe 3 065KE Apoktaten L 2
47. ay Dale and Torrie Copy Delete Set As Startup sylem Information 4 Select the name of the startup application from the Name list 5 Click Set As Startup 31 Chapter 2 Configuration Mode 38 Follow these steps to select or change the startup application from the C200 or C300 terminal 1 Click Startup Application from the Main menu D Allen Bradley PanelView C200 Communication gt Startup Application 3 Press F4 to exit to the main menu 4 Click on File Manager from the main menu 5 Press F1 to select the source either internal or USB O Allen Bradley PanelView C200 6 Press F3 to go to the list of applications and use the arrows to select the startup application D Alen Bradioy PanelView C200 Lani al F2M i ZON F3 gt O 4lfen Eradioy PanelView C200 8 Press F4 to exit to the main menu Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 Change the Date and Time You can adjust the current date and time for terminal operations The time is set in 24 hour format You can also set the terminal to automatically adjust the time for daylight savings time Follow these steps to change the terminal date and time using the PanelView Explorer Startup window 1 2 Publication 2711C UM001B EN P September 2008 Go to the PanelView Explorer Startup window Click the Terminal Settings link Click the System Information tab Update the Cu
48. but does not remove user applications from the terminal The main dialog of the utility looks like this You can perform maintenance operations separately or together by clicking the corresponding checkboxes The screen shows all boxes checked FIL Sink Amine ok Le Maintenance Utilities Begin waiting for fer connection perform these operations connect requests gt A pr AF N E wr poate FEN a ean ME 2506 1 i E 1 x C Temp SC 01 01 002 IMG Browse Started istening for BOOTME requests on port 980 The utility always requires a companion firmware image SC XX XX IMG even if you are only performing a clean file system or clean registry operation The utility is on the CD that is shipped with your terminal and the firmware image is downloaded from the website http ab com eoi graphicterminals panelviewcomponent html The utility requires that you connect the USB host port of your computer to the USB device port on the terminal Maa cefore connecting your computer to the USB port of the PanelView Component terminal you must first install the Allen Bradley PanelView USB remote NDIS Network Device driver on your computer Refer to Install the USB Driver on page 61 116 Publication 2711C UM001B EN P September 2008 Firmware Update Utility Appendix D Install the Utility The firmware update utility is on the CD that ships with your computer Follow these steps to install the firmware update util
49. cha file from your computer or SD card 1026 Recipe Upload Failed This message is for informational purposes No corrective action needed 1027 Recipe operation in progress This message is for informational purposes No corrective action needed 2000 Loading This message is for informational purposes No corrective action needed 2001 Unloading This message is for informational purposes No 2002 corrective action needed Terminal is starting up This message Is for informational purposes No corrective action needed 2003 Application is currently being edited user input is Put the application into Test or Run mode to enable disabled user input 2004 Copying file This message is for informational purposes No corrective action needed 2005 Deleting file This message Is for informational purposes No corrective action needed 2006 Operation failed This message is for informational purposes No corrective action needed 2007 Operation succeeded This message is for informational purposes No corrective action needed 2008 Cannot run application Application version Edit validate and then save the application with incompatible this version and try again Cannot run application Communication connection Terminal does not support the communication not supported connection configured in this application Edit the application and configure communication for the Supported connection type 2010
50. ck Cancel to restore the current idle timeout The new password and idle timeout value take effect when the terminal is restarted To disable security uncheck the Terminal Security Enabled checkbox The next time the terminal is restarted the design environment is unsecured The terminal user name and password is stored in a file that is separate from the application You can transfer this file to other terminals without having to manually re enter the information Use the File Transfer link on the PanelView Explorer Startup window and transfer the Terminal User file from internal storage to your computer USB or SD storage 46 Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 Publication 2711C UM001B EN P September 2008 View System Information You can view system information about your terminal including information about the firmware boot code logic board battery status Gif applicable terminal on time and memory used Follow these steps to view system information using the PanelView Explorer Startup window 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the System Information tab PanelView Component Dashboard File Transfer Help Sign Gif Displaying Sytem information Communication Terminal Security Finrmerare vursion Th ooo Boot Code version Th Logic Board version ho Banin satus Terminal on ime minutos Mernory Weed 1
51. continue with overwrite Alert 2020 Cannot copy over loaded application Unload application and try again Alert 2021 Insufficient space to complete file copy Remove files to free space from the destination and try again Alert 2022 Source and destination cannot be the same Verify the source and destination are not the same and retry Alert 2023 Application has been left in edit or test mode Reconnect the designer or press OK to proceed to the configuration screens Alert 2024 File not found Recipe 2025 Copy failed Only existing recipe files can be Create the recipe through the designer or rename updated this recipe to the existing recipe name and try again Recipe 2026 Copy failed Invalid recipe file The imported recipe must have the same number of ingredients and data sets as the existing recipe It Is replacing Alarm 2027 Alarm logs can only be copied from a loaded Load the application into Edit Test or Run mode application and retry NO O NO CO Alert Files can only be copied to a secured application The application has been secured with design while editing the application rights Load the application into Edit mode and retry Alert 2029 Files can only be copied from a secured application The application has been secured with design while editing the application rights Load the application into Edit mode and retry Alert 2030 Cannot delete a loaded application Unload applicat
52. d have at least an Intel Pentium M 1400 MHz processor with 512 MB RAM You must enter the IP address of the PanelView Component terminal into the address field of your browser You can find the IP address on the terminal configuration screen under Communications 10 Publication 2711C UM001B EN P September 2008 Overview Chapter 1 USB Port The PanelView Component terminals have a USB device port to support communication with the terminal using TCP IP ai before connecting your computer to the USB port of the PanelView Component terminal you must first install the Allen Bradley PanelView USB remote NDIS Network Device driver on your computer Refer to Install the USB Driver on page 61 With the USB device port connected to a computer use your computer s browser to connect to the terminal The IP address of the USB port is always 169 254 254 2 Ethernet Port The C600 and C1000 terminals have an Ethernet port The Ethernet port supports both static IP addresses and Dynamic Host Configuration Protocol DHCP assigned IP addresses If using static IP addressing then you manually set the IP address the subnet mask and the default gateway If using DHCP then the server automatically assigns an IP address the subnet mask the default gateway and the DNS and WINS server IMPORTANT If a terminal is set for DHCP and is not on a network or Is on a network that does not have a DHCP server or the server is not availabl
53. d the remaining properties require updates If trying to run an application you are warned that the application was not created for the terminal but you are given an option to continue or cancel unless the differences make it impossible to run the application for example an Ethernet application on a terminal without an Ethernet network connection PanelView Component applications are saved with a cha file type You cannot edit the file outside of the PanelView Explorer design environment Export an Application During an export the application file is transferred from internal storage of the terminal to a USB Flash Drive SD card or computer The application is saved with its default name and cha file type Follow these steps to export an application 1 Go to the PanelView Explorer Startup window 2 Click the File Transfer link 3 Click the New transfer button 4 Select Internal Storage as the source location of the application and click Next 5 Select Application as the file type and click Next 6 Select the application you want to export and click Next 7 Select the destination for the application and click Transfer 8 Click Save in the File Download dialog 9 In the Save As dialog accept the default file name and cha file type and click Save or enter another path 10 Click Close when the download is complete Publication 2711C UM001B EN P September 2008 51 Chapter 2 Configuration Mode Transferr
54. duce its size by removing some objects for example user controls screens tags or alarms Please unload application and try again Please try to release some memory or this may lead to fatal error Either add the specified language and associated strings or remove the unconfigured language selection 85 Chapter6 Troubleshoot the System Troubleshooting 86 If your terminal does not start up correctly check for adequate power observe the splash screen state message and status code indicator states or an application that is not running during powerup Determine what changed since the last time the terminal ran normally and decide if the change can be reversed Check for Adequate Power A terminal that does not receive adequate power could cause unpredictable behavior Verify the power requirements in the Specifications table Observe Splash Screen Various actions and status conditions of the terminal are reported on the splash screen including version information about the hardware and firmware State Message Hardware Version Boot Loader Status or Error Version Code Firmware Progress Bar Version These tables describe the state messages and the status or error codes that appear on the splash screen Power on Self test POST Failures Message State Code POST Failed RAM 6C POST Stuck Key 31 POST Stuck Touch 3A Publication 2711C UM001B EN P September 2008 Troubleshoot the System
55. e it will automatically assign itself an Automatic Private IP Address or auto IP address The auto IP address will be in the range of 169 254 0 0 through 169 254 255 255 The terminal makes sure the auto IP address is unique from any other auto IP address of other devices on the network The terminal can now communicate with other devices on the network that have IP addresses in the 169 254 xxx xxx range and a subnet mask of 255 255 0 0 PanelView Explorer PanelView Explorer is the design environment for the PanelView Component terminals You access the design environment through your browser while connected to the terminal Applications created in the design environment are simultaneously viewed on the connected terminal In addition to graphic objects and drawings the design environment provides support for communication tags alarms security recipes and language support Publication 2711C UM001B EN P September 2008 11 Chapter 1 Overview How to Display Help PanelView Explorer software provides extensive help for the design environment Context sensitive help is available for e each navigation tab e each object in the object palette e any dialog that has a Help button Click the on the application toolbar to view the help No Help Files Found To view help information in your browser you must copy the help files from the WebHelp folder of the CD that ships with your terminal to external media and then insert
56. e application and save prior to performing this operation otherwise changes to the application may be lost Alert 2053 Screen switching controlled by external source screen navigation devices are disabled if the screen has been changed to via controller Alert Cannot reset the terminal in Safe mode Terminal reboot is disabled on the emulator Select Flash gt Save and then select File gt Reset gt Hard to reboot the emulator Alert 2055 Image exceeds maximum resolution of 800x800 Open file in image editor and reduce the resolution Alert 2056 Cannot copy recipe to a loaded application Please unload application and try again 84 Publication 2711C UM001B EN P September 2008 NO O al NO NO al Es PanelView Component Terminal Alerts Category Alert Alert Alert Alert Alert Alert Alert Multilanguage 2057 Terminal is running low on application memory lt Available_Virtual_ Memory gt bytes 2058 2059 2060 Terminal is running low on RAM lt Available_RAM gt bytes Out of memory Terminal cannot continue to run and will be reset 2055 Cannot copy recipe to a loaded application 3001 8193 Failed setting property S 0 Param1 S 0 Param2 value S 0 Param3 Failed setting property S 0 Param1 S 0 Param2 S 0 Param3 value S 0 Param4 Available memory is too low to run the application language switch ignored Application was not
57. e major and 23 is the minor version number The firmware version for the terminal is displayed on the System Information screen TIP The firmware version information appears in the filename of the firmware file that is downloaded from the PanelView Component technical support website for example 2711C FUP 01 23 EXE ATTENTION Changing the firmware will likely change the behavior of the terminal Be aware of the firmware versions for the terminal TIP TIP TIP versus the new firmware that is on the computer and be informed of the expected behavior after the new firmware Is installed on the terminal Publication 2711C UM001B EN P September 2008 73 Chapter5 Upgrade Firmware Prepare the Storage Device Follow these steps to prepare the storage device to transfer firmware files 1 Insert the storage device into a USB host port or an SD card slot that is on your computer Open a web browser and access the PanelView Component technical support website Locate the new firmware file Observe the firmware version information that is in the name of the firmware file and confirm that this is the new desired firmware Download the firmware file to a folder on your computer then open the file and unpack the contents of the firmware file to an SD card or USB flash drive root directory Install the Firmware from the Storage Device Follow these steps to transfer firmware files from a storage device 1
58. e terminal firmware The utility supports a firmware maintenance capability that is independent of the operating system and or the other firmware elements on the terminal Use the utility only to recover from fatal conditions e A non functioning operating system that resulted from a failed or interrupted firmware upgrade e A corrupted file system that blocks the operating system e A corrupted Windows registry that blocks the operating system The utility always requires a companion firmware image SC XX XX IMG even if you are only performing a Clean File System or Clean Registry operation The utility is on the CD that is shipped with your terminal and the firmware image is downloaded from the website htto ab com eoi eraphicterminals panelviewcomponent html 115 Appendix D Firmware Update Utility The utility lets you perform these operations separately or together e Update Firmware installs a new or changed firmware image e Clean File System formats the entire file system All user added content and user applications in the file system are erased including all changes to the Windows registry The system reverts to a default registry This operation also performs a clean registry operation since the registry is a file e Clean Registry erases all changes to the Windows registry The system reverts to a default registry This operation removes registry settings such as the user s selected startup application
59. e the arrows to select the brightness Brightness 1 100 increments of 1 Allen Bradley PanelView C300 Screen Saver Allen Bradley PanelView C300 Screen Saver 5 Press F1 to select the time Choices are 1 2 5 10 15 20 30 or 60 min 28 Publication 2711C UM001B EN P September 2008 Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 Replace the Screen Saver Image The default screen saver image is a floating Allen Bradley logo in a bitmap format The name of the default screen saver is Screen Saver with a bmp file type You can replace the default screen saver with your own bitmap image but the file must have the same name as the default screen saver Follow these steps to replace the screen saver image 1 Create a small bitmap image 2 Rename your bitmap file to Screen Saver and make sure the file type is bmp 3 Select Run from the Start menu to open the Run window 4 Type the IP address of your PanelView terminal in the Open field using the format 169 254 254 2 5 Double click the Screen Saver folder 6 Copy and paste your Screen Saver bitmap file to this folder to replace the existing bitmap file The new screen saver takes effect the next time the screen saver is activated TIP Your bitmap file should be small in size A large bitmap will impact performance of terminal operations 29 Chapter 2 30 Configuration Mode Configure Key
60. eh oe Sl EE ee 95 pora Oia C a amp pia penas ee Ah de Heed ras 95 Remove a Fontela oxen mane SU dh Ae Eke ee E 96 Appendix C CON CIVIC Wee ee or tee Ga ag de Behe ds 99 stale Emulator isso ona 50 b085oR044 99 iaa AAA ba eat hae 106 Directory Layout and CONSE 4 au tee ee oe ek 108 Launch Mechas ce 24426545654 282406 A edo 110 Usine the Emul sssaaa eii bad dde 111 A A ry eS hard eee a Bee 112 Appendix D OCHA DIE OD E CUYOS emu venta d toe pu BH poll ds 115 ADOURUING MI a ds rastas dea 115 asta TUU a ed reae Bode T EA Bae 117 Update Ae ahah oan EREEREER E 118 Clean File System or Clean Recs aeinn EER EE E ER EER 121 SOltware Maintenance iia Satie ai Seem 122 Publication 2711C UM001B EN P September 2008 Preface Objectives Intended Audience Additional Resources This preface provides information on these topics e Intended audience e Additional resources e Firmware upgrades Use this manual if you are responsible for operating or troubleshooting the PanelView Component terminals This manual provides information for configuring the PanelView Component terminal You can configure the terminal on the terminal through a web browser on a computer connected to the terminal or through the PanelView Component emulator This manual does not give procedures for creating applications that run on the terminal No special knowledge is required to understand this manual or operate the terminal Equipment installers must
61. ember 2008 PanelView Component Emulator Appendix C 4 Select the installation type You can select between Complete Express or Custom installation Complete installs all components at the default installation locations and with all default user options Custom causes the installer to bring up a dialog that allows you to customize the installation process Express only installs the PanelView Component Emulator Use Express install for upgrading the firmware of the emulator nh F i i lg PanelView Component Emulator wi 0 Setup Type Choose the setup bypa that best agbs pour needs Pisassa select a s bu Hypa Al program features wall be retailed Requres the moat dek pare Orbe retal He Paneles Component Emulator Pastura Recommended if a presos complete rial already exists on thes pampata Chose which program features you want stalled and where they vel be retibed Decomimrearded for achvarced ears 5 If you selected custom setup you to select individual components to install select install paths where appropriate and select install options where appropriate ie PanelView Component Emulator vi 0 Custom Setup Salact the program faatures you wean inechalerd Ekk on An icon in tha bt besi w to change hos a feature it inctamed Mhonggoft DemceEmalator J Moost Locobadk Adapter Maosot Viebual PC 2007 JE instal to Program Files filler llr ale Publication 2711C UM001B EN P September
62. erminal Contact technical support providing this data ID1 S 0 Param1 ID2 S 0 Param2 P1 S 0 Param3 P2 S 0 Param4 P3 S 0 Param5 P4 S 0 Param6 Reboot the terminal Contact technical support providing this data ID1 S 0 Param1 ID2 S 0 Param2 P1 S 0 Param3 P2 S 0 Param4 P3 S 0 Param5 P4 S 0 Param6 P5 S 0 Param7 Reboot the terminal Publication 2711C UM001B EN P September 2008 Troubleshoot the System Chapter 6 PanelView Component Terminal Alerts Category Communication Communication Server Error Communication Communication Server Error Communication 10 Write Error for Alias 5 0 Param2 Controller S 0 Param3 Address is 5 0 Param4 Communication Flag is S 0 Param1 The terminal is having trouble writing the external tag at this controller and address Read Error for Alias S 0 Param2 Controller S 0 Param3 Address is S 0 Param4 Communication Flag is S 0 Param1 Communication The terminal is having trouble reading the external tag at this controller and address Publication 2711C UM001B EN P September 2008 Contact technical support providing this data ID1 S 0 Param1 ID2 S 0 Param2 P1 S 0 Param3 P2 S 0 Param4 P3 S 0 Paramb P4 S 0 Param6 P5 S 0 Param7 P6 S 0 Param8 Reboot the terminal Contact technical support providing this data ID1 S 0 Param1 ID2 S 0 Param2
63. erminal and computer and the type of terminal Language Shows the current and available languages for the design time software Create New Application Opens a new application in the design time environment window Edit Test Run Use these buttons to edit test and run the currently loaded application co O N O al Available Applications shows a list of applications stored on the terminal USB memory SD card or PC Storage on the emulator The list also shows If the file has been validated for correct operation 10 Stop Click the Stop button the stop sign shown when an app is loaded and in Edit Test Run mode to unload the currently loaded application If you have not saved changes to the application you are prompted to do so Once the application is unloaded the terminal displays the Configuration screen Publication 2711C UM001B EN P September 2008 19 Chapter 2 Configuration Mode Terminal Settings 20 Terminal settings can be set on the terminal or through the PanelView Explorer Startup window Adjusting Settings on the Terminal From the terminal you can view and edit the terminal settings The settings take effect immediately By clicking the menu items on the screen you can e switch to the currently running application e configure the terminal language e change the current application e adjust the display brightness and contrast e configure screen saver settings e calibrate the touc
64. ew USU RNS Driver ES Installshield Wizard Completed The Intabihed Winand has suecos installed Pare LSE ANDIS Cochin Chk Frish to ext the wizard The drivers are now installed Publication 2711C UM001B EN P September 2008 Cable Connections and Communication Chapter 4 Configure the Terminal for USB Connection Follow these steps to configure your terminal to be connected through a USB port to a computer 1 Connect the USB host port on the computer to the USB device port on the terminal IMPORTANT The terminal should be directly connected to a USB port on the computer Do not connect through some other device such as a USB port on a monitor keyboard or laptop computer docking station 2 Power up the terminal When the terminal connects to the computer for the first time the new USB device the PanelView Component terminal is discovered by the Windows Found New Hardware Wizard that guides you through the installation There are two instances of the driver There is one for the Boot Loader and one for the Windows CE Operating System The USB IP address is always 169 254 254 2 Found Hew Hardware Wizard Publication 2711C UM001B EN P September 2008 Welcome to the Found New Hardware Wizard Window wll peach hor cuien ard updsted poltware by koking on pour computer on the hardware inetallahon CO cr on Ihe W ridows Update Web be eal yout penner Read pii piaty pokes Can Windows cor
65. fined objects chu also known as library objects created in one application to another terminal for use with other applications In your application the user defined objects are added to the graphics library of the object palette They are stored in terminal storage separate from the application and can be accessed from any application on the terminal or emulator The names of user defined objects must begin with an alpha character Publication 2711C UM001B EN P September 2008 Chapter 3 Install and Replace Components Chapter Objectives This chapter shows how to install replace or upgrade various components of the PanelView component terminals e SD memory card e USB flash drive e Battery replacement SD Memory Card The SD memory card can be inserted in this location on the C600 and C1000 terminals SD Memory Card Slot USB Flash Drive The USB flash drive can be inserted in these locations on the terminals USB Connector C200 and C300 USB Connector C600 and C1000 Publication 2711C UM001A EN P May 2008 53 Chapter 3 Install and Replace Components Battery Replacement The C600 and C1000 terminals contain a lithium battery that is intended to be replaced during the life of the product The battery provides battery backup for the real time clock It is not used for application backup or retention ATTENTION Verify that power has been removed from the terminal prior to replacing the battery Wor
66. formation tab 4 Select a language from the Terminal Language pull down list PanelView Component Dashboard Pie Traeveter Help Sign On Display Input System Information Communication Terminal Security Florine voralar TE Current Dale Marth Day Yaar jaan podaran JE August e7 2000 Logit Bown version fin Currant Time Battery stalus Gond Hour Minule Second a milam og Terminal on lime m nules las 250 3 E S Mamor DAA m Dlautomateatty adjust for daylight savings time Startup Sppkaton a GM T Fache Tire Us 4 Canada Ae Amtal_ 1100 pe Terminal Language English _ M 5 Click Apply or click Cancel to restore the current setting Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 Publication 2711C UM001B EN P September 2008 On the C600 and C1000 terminals the default language is set on the Main menu Just click the up and down arrows to select the language Main Current Application File Manager Goto Communication Configuration Language Startup Application Portugu s Francais Display Italiana Deutsch Date and Time Espa ol System Information Follow these steps to change the language on the C200 and C300 terminals 1 Click Config Language pa ET PanelView C200 MA Config Language 4 pan Current Application IN vi 6 PE 2 Press F1 to select the language The display changes to the language you select immediately Al
67. h screen if supported e reboot or reset the terminal e view system information e change the startup application e change the current date and time e set Ethernet network communication Terminal Main Menu C200 C600 and C1000 Main i Config Language i fuer Appeal MO File Manager Lalek _ cen yn e Communication Startup Application Display Config Language File Manager Current Application Date and Time System Information Current Application Soto Configuration Language nalish Portuqu s Francais Italiano Deutsch Espa ol Es Reset Terminal These settings can also be changed using the PanelView Explorer Startup Window Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 Adjusting Settings on the PanelView Explorer Startup Window From the PanelView Explorer Startup window you can view and edit settings for the connected PanelView Component terminal The settings take effect immediately By clicking the Terminal Settings link on the PanelView Explorer Startup window you can access tabs to e adjust the display brightness and contrast e configure screen saver settings e configure key repeat settings e calibrate the touch screen Gif supported e reset the terminal e view system information e change the startup application e change the terminal language e change the current date and time e Ethernet communication e change the pa
68. he changes to this manual since the last publication To help you find new and updated information in this release of the manual we included change bars as shown to the right of this paragraph Topic Updated screen images to reflect changes to language support Updated website for firmware upgrades Updated terminal language information Updated battery information Removed the section that described how to upgrade firmware using a file copy from the computer Added information on installing Asian fonts Added information on how to perform maintenance and recovery operations Section Most sections page 8 page 22 page 94 Chapter 5 page 2 page 95 Appendix D summary of Changes 4 Publication 2711C UM001B EN P September 2008 Preface Overview Configuration Mode Install and Replace Components Cable Connections and Communication Upgrade Firmware Table of Contents O S60 oC ica dara liende d Aude eE Bd A E a ici Additional Resources Tuy Ae pot dosis pito tri dde Grand Et rie a de Chapter 1 Chapter ODE S ui Y e hones Haw bw as ea ADOUE Me TEMNA S dies die ana babe How to Connect DOWSEC 4 3 44 464225 Ad PanelView Explota viaria Howto Display cl Ad adi Peripheral Commecion cocer 2406524805 Catalog Number Configuration 0 00005 Chapter 2 CRAD OF ODOC AA Seka tn od eee ee aa Contisuration Mode aspas dus oe oe ees E ee Contisuratio n Interaces 24 5
69. he devices In addition to the NFPA guidelines connect the device and other similar electronic equipment to its own branch circuit protect the input power by a fuse or circuit breaker rated at no more than 15 A route incoming power to the device by a separate path from the communication lines cross power and communication lines at right angles if they must cross Communication lines can be installed in the same conduit as low level dc I O lines less that 10V shield and ground cables appropriately to avoid electromagnetic interference EMI Grounding minimizes noise from EMI and is a safety measure in electrical installation For more information on grounding recommendations refer to the National Electrical Code published by the National Fire Protection Association Publication 2711C UM001B EN P September 2008 55 Chapter4 Cable Connections and Communication Connecting Devices Use these cables for connecting devices to PanelView Component terminals Cables for PanelView Component Terminals 2 11C CBL UU02 USB A host to USB B device cable 2 m C200 C300 C600 6 56 ft C1000 2711P CBL EX04 Ethernet crossover CAT5 cable 4 3 m 14 ft C600 C1000 2711C RCSD USB to SD adapter with secure digital SD C200 C300 C600 card C1000 1747 CP3 serial 9 pin D shell to 9 pin D shell null C200 C300 C600 modem cable C1000 1761 CBL PM02 serial 9 pin D shell to 8 pin mini DIN cable C200 C300 C600
70. hernet device has a unique MAC ID Network Device Name Unique name that Identifies the terminal on IP Address Subnet Mask Default Gateway the network Unique address that identifies the terminal on the Ethernet network The format of the IP address Is XXX XXX XXX XXX for example 10 90 95 30 The range of values for the first set of decimal numbers is 1 255 unless all fields are set to 000 The range of values for the last three sets of decimal numbers if 0 255 Address that must be identical to the server subnet mask The subnet mask is formatted like the IP address Optional address that is formatted like the IP address 41 Chapter 2 Configuration Mode If DHCP is enabled for the Ethernet port the current fields show the IP addresses assigned by the network You can assign IP addresses manually by disabling DHCP and entering addresses in the static fields Follow these steps to set a static IP address for the Ethernet port of the connected terminal using the PanelView Explorer Startup window 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the Communication tab PanelView Component Dashbeard Hile Iranrsier Help Shon Of NACE E System information Conummicaion Terminal Secimity MAC ID Ms ee a Network Device Mame USMEEEJST test USE Settings Ethernet Settings IF adimas 3 Cumont iP address Cs 0 909530 o Subnet mask i B Current Subnet ma
71. iew Component Emulator i 1 0 E 2711C F2M gt 2711C 2mM E 2711C K3M E 2711C T3M O 2711C Tec 2711C T6M gt 2711C T10C The install directory under the root is named PanelView Component Emulator This folder contains the script files required for launching the emulator Under the PanelView Component Emulator directory is the directory named where is the major and minor version number of the emulator This format allows later versions of the emulator to be installed without disrupting previous installations Emulator Versions Folders x Hama zza Type Data Modified W My Computer a E File Folder 421 2006 5 12 PM a A 3 Floppy 4 3271 ic Kem Fis Fodder 2 21 2000 5 12 PM ijh Man Orive C 271 1CAc3m File Folder 2 21 2008 5 12 PM Ey Progr a Fiss 3271 1C T13M Fila Folder 2 21 2006 5 12 PA E Adobe z7iic tec Ede Folder 2 21 2008 5 12 PM Do Allen Bradley zr i ic Tem File Fiker 2212000 5 12 PH 3 E Paneiview Component Emulator Gco File Folder 2 21 2008 5 12 PM Geta E PeEm bin 26 026 KH BIN Fis 2 16 2008 11 18 AM 27110 F2m I 2711C42M C 2711CA43M ES 27110 Tam 2711 Tec E 27110 T6M Co 27110 TH0C 109 Appendix PanelView Component Emulator Launch Mechanism 110 There is a subdirectory for each terminal type The subdirectory name is the catalog number for the respective terminal type These subdirectories contain the files that define each emulated terminal image and behavior The files mak
72. ing User defined Objects 52 Import an Application During an import the cha application file is transferred from a USB Flash Drive SD card or computer to the internal storage of the terminal The transfer operation communicates with the terminal to import the file You cannot overwrite an application while the application is running You must unload the current application before overwriting the application You can import applications while another is running Follow these steps to import an application 1 Go to the PanelView Explorer Startup window 2 If an application is currently loaded click the stop sign above the dashboard to unload the current application 3 Click the File Transfer link 4 Click New Transfer 5 Select the source location of the application and click Next 6 Select Application as the file type and click Next 7 Click Browse to locate the cha file you want to import 8 Select Internal Storage as the destination and click Transfer The application is transferred to the internal storage of the terminal If an application with the same name already exists in internal storage you will be asked if you want to replace the existing application If the target terminal is a different type and size then the source terminal the application will be converted when in Edit Test Run or Run mode The application may require updates in design mode before running properly You can transfer user de
73. ing up the emulator contain the base name of the terminal catalog Terminal Subdirectory Folders Mama Sing Typ Date Mocited My Computer a E ERM1C T10C or LKB XML Document 1 4 2008 1 13 PH EL 344 Floppy A 3 2711C T10C_Donbmp 1 P90KB Bitmap image 1 4 2008 1 13PM J e Main Drive Ci SL 2711C T10C_Madi bmp 1 998 KE Bitmap image 1 4 2008 1 19PM 5 E Program Fies 5 27110 T10C_Up bmp LGE Blimap Image 1 4 2008 1 13 Ph ul Ey Adobe E Allen dradiey 3 CD Paneles Component Emulate 1 0 E 2711 2 a A 2710 4 D 271 10 134 E 210 160 27110 16M 9 micen Mapped Share Folder The emulator is launched with the command line option that maps a PC folder into the emulator s file system The given computer folder is referred to as the Mapped Share folder The default location for this mapped share folder is shown address 29 C Documents and Settings All Users Documents Allen Bradley P c Emulator Folders X Name Y My Computer A a 314 Floppy 4 s Main Drive C 3 E Documents and Settings 2 1 all users 5 Shared Documents 6 Ajlen Bradiey t Pie Emulator However the installer allows the user to optionally select a different location for this shared folder There are two primary ways to launch the PanelView Component emulator The first is via entries in the Windows Start Menu The second is via double clicking a PanelView Component user application file cha Publication 2711C UM001B E
74. interface The design time user interface requires a computer browser connected to the terminal s web service where the runtime user interface uses configuration screens on the terminal The configuration data for a terminal refers to the collection of all of the system interface parameters Access to the Terminal s Configuration Running Internet Explorer or p Firefox browser __ USB or Ethernet connectivity On Terminal Configuration Publication 2711C UM001B EN P September 2008 15 Chapter 2 Configuration Mode Design time Configuration The design time configuration is when the terminal is actually hosting web server content that represents a visualization of the terminal s properties and files You can only design for the terminal type that you are connected to When a new application is created the design time automatically navigates to the first screen and assigns it as the startup screen The design time environment is compatible with these operating systems e Windows 2000 catalog numbers 2711C T6M 2711C T6C and 2711C T10C only using an Ethernet connection to connect to the terminal e Windows XP e Windows Vista Connecting to a terminal using a USB connection is not compatible with Windows 2000 operating system The PanelView Component emulator is not compatible with Windows 2000 operating system A user application can be created or edited through a browser connected to a termin
75. ion and try again NO oO Alert Files can only be deleted from a secured The application has been secured with design application while editing the application rights Load the application into Edit mode and retry Alert 2032 Return to out of box condition Press Yes to reboot the terminal and return to the out of box condition Alert 2033 Source file does not exist Make sure the source file exists and retry Publication 2711C UM001B EN P September 2008 83 Chapter6 Troubleshoot the System PanelView Component Terminal Alerts Alert 2034 Destination folder does not exist Make sure the destination location exists and retry Alert 2035 Insufficient disk space Please free disk space and Remove files to free space by pressing the Delete try again File button on the File Transfer tab Alert 2036 Cannot run an invalid startup application Press OK to proceed to the configuration screens Then edit and validate the application Correct all validation errors save the application and try again Alert 2038 Cannot change password because password has been marked as unmodifiable Edit the application and go to the Security tab Check the Modifiable box associated with the username and password Alert 2039 Cannot change password because no user is Log on as one of the users defined in the logged onto the terminal application and retry Alert 2040 Old password does not match the password for the En
76. ity on your computer 1 Double click PVcFwUpSetup in the Firmware Firmware Utility folder on the CD ie Panel iew Component Firmware Update Utility Welcome to the PanelView Component Firmware Update Utility Setup Wizard he installer yal quide you through the steps requared to install PanelView Lomponent Famware Update Utiity on pour computer WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law 2 Click Next T Panel iew Component Firmware Update Utility Select Installation Folder The installer will install Panel iew Component Firmware Update Utility to the following folder To install in this folder click Next To ingtall to a different folder enter it below or click Browse Folder C 4Program Files Allen Bradley PaneMiew Component Firmware Upde Browse Disk Cost Install Panel iew Component Firmware Update Utility for yourself or for anyone who uses this computer i Evenone Just me Cancel lt Back E You have the option of clicking Browse to change the folder location and to install the utility for anyone who uses this computer or the person currently logged on 3 Click Next to install the utility to the folder location Publication 2711
77. k in a static free environment and wear a properly grounded electrostatic discharge ESD wristband Be careful when touching any of the exposed electronic components to prevent damage from ESD To avoid the danger of explosion only replace the battery with 2711P RY2032 or a manufacturer s equivalent such as the Matsushita or Duracell DL2032 For safety information on the handling of lithium batteries see the Guidelines for Handling Lithium Batteries publication AG 5 4 Do not dispose of battery in a fire or incinerator Dispose of used batteries in accordance with local regulations The battery is on the back of the terminals No special tools are required to remove the battery cover and replace the battery Battery Cover At the end of its life the used battery should be collected separately from any unsorted municipal waste and recycled 54 Publication 2711C UM001A EN P May 2008 Chapter Objectives Wiring and Safety Guidelines Chapter 4 Cable Connections and Communication This chapter provides network and device connections for the terminals e Wiring and safety guidelines Connecting devices e MicroLogix controller cable charts Ethernet connection Serial connections USB Ports Use publication NFPA 70E Electrical Safety Requirements for Employee Workplaces IEC 60364 Electrical Installations in Buildings or other applicable wiring safety requirements for the country of installation when wiring t
78. le to enumerate emulator registry parameters 112 Publication 2711C UM001B EN P September 2008 PanelView Component Emulator Appendix C PVcEmLaunch Error Codes 0x20009 lt keyname gt Base emulator command string not found in registry 1 Error constructing emulator command string 2 lt keyname gt Base web browser command string not found in registry 3 Error constructing web browser command string 0x2000B Failed launching the emulator 0x2000C ooo Emulator failed to start timeout 0x2000D PO Failed launching web browser Publication 2711C UM001B EN P September 2008 113 Appendix C PanelView Component Emulator 114 Publication 2711C UM001B EN P September 2008 Chapter Objectives About the Utility Publication 2711C UM001B EN P September 2008 Appendix D Firmware Update Utility This appendix shows how to use the PanelView Component Firmware Update Utility to perform recovery and maintenance operations on a PanelView Component terminal that is in a non operating state IMPORTANT Use the utility described in this appendix only if the terminal is not operable Always use the firmware upgrade described in Chapter 5 when you want to upgrade firmware to an operating terminal and functioning operating system TIP The PanelView Component Firmware Update Utility is a PC application that interacts with the Boot Loader on the terminal via a USB connection to perform maintenance actions on th
79. len Bradley Panel View C200 a runtime diagnostic messages appear in the same language as the application if the application language is English Portuguese French Italian German Spanish Chinese or Korean For all other languages the diagnostic messages appear in the configuration language set on the terminal 23 Chapter 2 24 Configuration Mode Adjust the Display Brightness and Contrast You can modify the brightness and contrast of the terminal display You can use the default intensity of 50 for contrast and 100 for brightness or adjust the intensity for runtime operations TIP On the C1000 terminal only the brightness can be changed Follow these steps to change the display brightness and contrast using the PanelView Explorer Startup window 1 2 3 F Display input System information Communication Terminai Security Go to the PanelView Explorer Startup window Click the Terminal Settings link Click the Display Input tab Drag the slider to adjust the brightness level between 1 100 Drag the slider to adjust the contrast level between 1 100 Click Apply or click Cancel to restore the current terminal settings Displana input Devices Brightness 100 NJ Enable key repeat _ 22 A _ __ _ ___ A22 EJ Key Repeal Rata Contrast 50 De o eee Key Rapel Delay Sgen Savor modo E Frable Screen Sewer and Dimmar Heboot I errand Ser n saver
80. location the location of the file you want to transfer You can transfer a file from Internal Storage of the terminal USB storage SD Storage or My Computer e Source File Type the type of file you want to transfer The types of files you can transfer include PanelView Component applications images user defined objects fonts recipes and the terminal security file e Destination location The location where you want to transfer the selected file You can transfer a file to Internal Storage of the terminal USB Storage SD Storage or My Computer If transferring a file from or to USB or SD storage verify that the USB flash drive or SD card is inserted in the terminal before starting the file transfer Applications created on one PanelView Component terminal can be used on other PanelView Component terminals For example you might design an application on one terminal and then distribute the application to other terminals for production Transferring an application is a two step process e Export the application from the internal storage of the terminal to your computer a USB Flash Drive or SD card e Import the application from a computer USB Flash Drive or SD card to the internal storage of another terminal Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 If the target terminal is a different type and size than the source terminal some aspects of the application is converted an
81. mecl bo Windows Update bo search ho po wara 7 Yea this time only Tes now and ever ime connect a device No nt ie bind Clack Heyl bo corel 65 Chapter4 Cable Connections and Communication 3 Choose Install the software automatically and click next Found Hew Hardware Wizard Thor vazad help you melal polar hu Allen Bradey PaneMiew Boct Loader USE Remote MDIS Hehacek Desie IF your hardware came with an installation CO lt E on floppy disk insert it now What do you vant the vazand bo do puted the sollvesse autrenahe aly Hecomenendes E instal from a het specific location bAcvanced Clack Hex bo corre The wizard searches for the files Found Hew Hardware Wizard Plaate mai while the wizard searches En Ale Bradley Panel isw Boot Loader USE Remote HOIS Netvecek Chavace 4 Ifthe Windows Logo Test warning dialog box is displayed click Continue Anyway Hardware Installation A The setve you are natalie ite thes hardware Alerta Pansies Hoot Loader USE Female HIIS Mehak ENTE has nal pared Wirde Logo bering lo veiy ds compatibelly wh Windows aP Tell me why this tering i npodant Continuing pour installation of thia software may impair of destabilize the conccl operation of pour syatem fier immediately on on the hubs Micnocolt strongly recommends ihal pou slop tho mnstalleion mow and contact the hardware vendor for coltwane thal has passed Windows Logo beating
82. n Follow these steps to reboot the terminal from the PanelView Explorer Startup window 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the Display Input tab 4 Click Reboot Terminal button AB PanelView Component Mashina File Transfer Help Sign Off o Displayinput System information Communication Terminal Security ARAU O PRO ELS NA all i RAE Display Input Devices Brightness 100 C Enable key repeat cm 11 Ker Repeat Rate Conbash Bi G e Key Repeal Delay E Seren saver mode m 5 Ennble Screen dover and Dire 4 en acreen saver timieout Caio Touch Saleen 1 mane Sereen caver bighiness 5 Cronos ERE Chapter 2 Configuration Mode 34 Follow these steps to reboot the terminal from the C600 and C1000 terminals 1 Go to the Main configuration screen 2 Press Reset Terminal Main Current Application File Manager Goto Communication Startup Application Display Date and Time 3 Confirm reset Current Application wl Configuration Language File Marne Communication Startup Application Display Date and Time System infomation Configuration Language nglish Portugu s Fran ais Italiano Deutsch Espa ol fal CP 32 System Information Reset Terminal Francars Italian Devisch Espa al Publication 2711C UM001B EN P September 2008 Configurati
83. n sawer brighiness 5 Fishesh Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 Publication 2711C UM001B EN P September 2008 5 Select a time from the pull down list to adjust the screen saver timeout 6 Drag the slider to adjust the screen saver brightness 7 Click Apply or click Cancel to restore the current screen saver settings To disable the screen saver or dimmers select Disable Screen Saver and Dimmer from the screen saver mode list Follow these steps to configure the screen saver from the C600 and C1000 terminals 1 Click Display on the menu list 2 Click More at the bottom of the screen 3 Select the Mode Mode Image Disable Dimmer Image and Dimmer 4 Select the brightness Brightness 1 100 increments of 1 5 Select the idle time Choices are 1 2 5 10 15 20 30 or 60 min Main Screen Saver File Manager Image E Vv made PA Dimmer Communication A Brightness ARV Date and Time System Information HS 21 Chapter 2 Configuration Mode Follow these steps to configure the screen saver from the C200 and C300 terminals 1 Select Screen Saver on the menu list and press the enter key Allen Bradley PanelView C300 Display b Screen Saver System Information 2 Press F1 to select the Mode Mode Image Disable Dimmer Image and Dimmer Allen Bradley PanelView C300 Screen Saver age amp Dirnrme 3 Press F3 and us
84. nd Time System Information System Information Firmware Version Boot Code Version Logic Board Version Terminal On Time Display On Time Battery Status Hot Available 2 Click More to view additional information about the terminal File Manager Communication Startup Application Display Date and Time System Information Memory Usage bytes Internal Used 1 660 928 Internal Free 19 272 528 Application Used 14 864 964 Application Free 34 181 120 49 Chapter 2 Configuration Mode Managing Applications and Files Transferring Applications 50 The PanelView Explorer Startup window has a File Transfer link for transferring files to and from terminal storage media File names and tag names should start with an alpha character Avoid starting names with numeric or special characters From the File Transfer view you can e export or import applications user defined objects images the terminal security file recipes and fonts e export the alarm log from the currently running application e delete applications user defined objects images font files terminal user file and recipes from terminal storage TIP For more Information on creating applications and transferring files see PanelView Component Operator Terminals Quick start publication 2711C QS001 A file transfer operation requires you to enter a source location file type and destination location e Source
85. of the file system PC Storage can be mapped to a folder in your computer s file system Anything stored in the mapped folder can be accessed by both the emulator and your computer By default on the emulator applications are saved to the mapped folder PC Storage Install the Emulator The PanelView Component emulator can be installed on computers running Windows XP SP2 or Windows Vista For better emulator performance your computer should have at least an Intel Pentium M 1400 MHz processor with 512MB RAM Your computer information can be found by right clicking on My Computer and selecting properties The PanelView Component Emulator Installer installs the following five components If you select Full Install all five of these components are installed If you select Custom Install you have the option of selecting which of these components are installed e Microsoft Device Emulator e Microsoft Virtual PC e Microsoft Loopback adapter e PanelView Component Emulator e Extended support files fonts demos graphics help Publication 2711C UM001B EN P September 2008 99 Appendix C PanelView Component Emulator Follow these steps to install the emulator components 1 Insert CD or go to web site to install emulator components The InstallShield Wizard appears InstallShield Wizard a Panelview Component Emulator v1 0 Setup is preparing the ee install held Wizard which wall guide you through the program l
86. on Mode Chapter 2 Follow these steps to reboot the terminal from the C200 and C300 terminals 1 Select Reset Terminal from the menu list Allen Bradley PanelView C300 Screen Saver System Information b Reset Terminal 2 Press F1 to reset the terminal Allen Bradley Panel View C300 Reset Terminal F4 Exit Fi F2 2 F3 gt Fa F6 0 FR gt Fee F9 3 Confirm restart Allen Bradley PanelView C300 Publication 2711C UM001B EN P September 2008 35 Chapter 2 Configuration Mode 36 Change the Startup Application You can select or change the application that runs on the terminal each time the terminal starts up You must also select the storage location of the application The options are internal storage of the terminal USB flash drive SD card or PC storage IMPORTANT If the application list is empty the run copy delete and set as Startup functions will not perform any action Follow these steps to select or change the startup application using the PanelView Explorer Startup window 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the System Information tab 4 Select the name of the startup application from the Startup Application pull down list PanelView Component Dishboard File Transter Help Sh OTT Display iu Systemiifonmati n Cammunication Terminal Secauriny Firrraware version TEE Cumont Dabo Manth
87. on Wizard dialog box appears Dewice Driver Installation Wizard Welcome to the Device Driver Installation Wizard Thor wizard helps pos lel lhe sodleare dreet ihai pone compubals devices need in onder Lo work To corras chek Next The drivers install Dewice Driver Installation Wizard The diver are now installing s Please wak while the dresis natal This may take some time lo complete Publication 2711C UM001B EN P September 2008 63 Chapter 4 64 Cable Connections and Communication 6 If the Windows Logo Test warning dialog box is displayed click Continue Anyway Sothwa ne Installation Th sedes pol are matakna has not passed Windows Lego tesbng to venh ds compustibiity wath Winco H hell me eti they bey e empatan Continuing pour installation of thia software may impair of desire the connec operahan of pour sychem elhe immediately of in the future Microrolt strongly recommend that pou stop this installation now and contact the software vendor for coltwane thal haz Cesarea STOP rao 7 Click Finish in the Device Driver Installation Wizard dialog box Dewice Driver Installation Wizard Completing the Device Driver Installation Wizard The diners wae poces incialied on the computar Vou tan now connect your dect lo the compad s Dl your dende came valh inclectorns peare read lusin Mil Dirree Mame Status Sv Alerts Company LUC Alea Pleady housa t 3 18 Fane i
88. on is unloaded the terminal displays the Configuration screen 3 Close the web browser connected to the terminal Publication 2711C UM001B EN P September 2008 71 Chapter5 Upgrade Firmware 4 Verify the existing firmware revision of the terminal by looking in the Configuration Screens and compare to the firmware revision of the file to make sure you are performing the desired upgrade Allen Bradley Main Spb Indormadion File MHararper Eire Vertin 01 00 ont Code Werthin 00 00 Tammimirsian Logic Hoard Vertinn 10 Slelup Applicalion ES Termal One Tima Display Display Gn Time Ihatbery Statui Bul Available Bale amd Tima Syilem Informalion Ea Refer to View Svstem Information on page 47 for instructions on how to view the current firmware version Firmware Installation Using The terminal can install firmware from a removable storage device Removable Storage Device 72 either a USB flash drive or an SD storage card The firmware consists of an Autorun executable and firmware images that is downloaded from the PanelView Component technical support website http ab com eoi graphicterminals panelviewcomponent html The firmware installation starts when the storage device is inserted either while the terminal is running or when the terminal is powered on During the firmware installation you can upgrade or downgrade one or more of these firmware images e Windows CE Operating System e Ap
89. ot received within the idle timeout period the user is logged out The user must log in again to access the terminal The default terminal idle timeout is 30 minutes Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 IMPORTANT store your password in a safe place If you forget the password you will not be able to connect to the design environment Follow these steps to secure the design environment 1 Goto the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the Terminal Security tab 4 Check Terminal Security Enabled 7 PanelView Component Display npn System Information Comnmicarian Terminal Security Terminal Security Li Terminal Security Enabled Termal User Terminal Lies Marne Ferer Terrenal Liner Parton Tem Tinea Terminal idle Timeout 30 minutes English Portugu s Frangals ttallano Deutsch Espa ol MCS BHA 5 Optionally enter a new Terminal User Name 6 Click the Reset Terminal User Password button Publication 2711C UM001B EN P September 2008 45 Chapter 2 Configuration Mode 7 In the Reset Password dialog enter a new password confirm the password then click OK TIP Terminal user names and passwords are limited to 15 characters Regal Password How Password Canim New Fas swan Ok Cancel 8 Select a new idle timeout from the Terminal Idle Timeout list if needed or cli
90. ow Click File Transfer Click Delete File Select the source location of the Font file typically Internal Storage and click Next Select Font as the file type and click Next Observe the list of all Font files that have been added to the Terminal Select the Font file that you want to delete and click Delete Observe the Confirmation message for the selected Font file and click OK Observe the informational message Deleting File Observe the deleted font file no longer appears in the list of all Font files Publication 2711C UM001B EN P September 2008 Adding Font Files Appendix B Publication 2711C UM001B EN P September 2008 10 Reboot the terminal to remove the file from the design environment If deleting a font from the emulator internal storage you need to Flash Save for it to be permanently stored in emulator Otherwise it s lost once you shut down To save to internal storage select Flash and then Save from the emulator s main window menu Font files especially East Asian Fonts are large and consume Significant space on Internal Storage Remove all unused fonts from the terminal 97 AppendixB Adding Font Files 98 Publication 2711C UM001B EN P September 2008 Appendix C PanelView Component Emulator Overview The PanelView Component terminal emulator is treated as a terminal and runs almost the exact same firmware The emulator has its own file system One folder
91. ows a progress screen PanelView Component Emulator v1 0 a A Please wait while Windows configures PanelView Component Emulator v1 0 Gathering required information AO After the last version of PanelView Component emulator is uninstalled you are asked if you want the mapped share folder removed 5 Click Yes or No on the Remove Share folder dialog Question o Remove the Emulator mapped Share directory the j The directory CuiDocuments and Settings All Users Documents Allen Bradley Pic Emulator Is no longer being used Delete this directory and its contents TIP Make note of this directory location If you plan to reinstall the emulator at a later date If you choose this same Share directory when reinstalling the emulator all your current files will be automatically available If you answer yes the folder and all its contents are deleted If you wish to preserve its contents answer no TIP By default the application files you create are stored in this folder If you wish to preserve the applications that you created answer no for the folder to remain on the computer 6 Follow the uninstall process for the Microsoft Device Emulator Microsoft Loopback Adapter and Virtual PC files from your computer if necessary The Microsoft Device Emulator Microsoft Loopback Adapter and Virtual PC could be used by other software packages Publication 2711C UM001B EN P September 2008 107
92. pears Main Static IP Address File Manager IP Address Communication Display Gateway Date and Time System Information 43 Chapter 2 Configuration Mode 44 4 Click on the area next to IP Address to enter an IP address in the Static IP address field A keypad displays to let you enter the address 5 Enter the subnet mask in the Static Subnet mask field 6 Enter the default gateway in the Static Default gateway field Main Static IP Address BW 95 11 13 res 2 3 4 Js e 7 fe Ja e e Si lalwielritiviulitolpt tt Carslalsldifiaihti tei ty Start tell weed S17 le binm Tite Geufwnpe gt To TWTaiel gt Date and Time System Information Enable Terminal Security Use terminal security to restrict user access to the terminal configuration screens and the PanelView Explorer Startup window For example you can require users to enter a user name and password before accessing or editing an application Initially the terminal and the PanelView Explorer Startup window are unsecured To enable security provide a password The default user name is Admin The new password takes effect the next time the terminal is restarted As long as security is enabled any user that tries to access the terminal or the design time environment while connected to the terminal must first log in with a valid user name and password The terminal also secures itself when idle If terminal input is n
93. plication e Communication e Asian font Chinese or Korean The terminal has a firmware partition that accommodates one user installable Asian font A Simsun Chinese font is factory installed Firmware images for the Simsun Chinese font and Gulim Korean font are on the CD that ships with the terminal and can be downloaded from the technical support website The currently installed Asian font firmware image Is TIP svete visible in the list of Configuration Languages on the Main Screen Publication 2711C UM001B EN P September 2008 Upgrade Firmware Chapter 5 ATTENTION Removing the USB flash drive or SD card from the PanelView Component terminal while a firmware upgrade Is in process could corrupt the firmware and make the terminal unusable Take precautions to prevent the USB flash drive or SD card from being accidentally disconnected Also do not power off the terminal while a firmware upgrade Is in progress USB hubs can produce unexpected behaviors and as a result are not recommended some USB flash drives might not be compatible with the PanelView Component terminal and might not support file transfers or firmware upgrades The catalog number 2711C RCSD memory card was tested with the PanelView Component terminal to ensure compatibility Only the C600 and C1000 support the SD Storage Card The firmware version consists of a major and minor two digit number separated by a period for example 01 23 where 01 is th
94. r the idle timeout elapses using a default screen saver image The screen saver deactivates when you press a key e Dimmer dims the display from full brightness to the brightness level you set when the idle timeout elapses While the display is dimmed you can still see on screen activity When you press a key the display is restored to full brightness e Screen saver and dimmer activates the screen saver and dims the display when the idle timeout elapses e Disable screen saver and dimmer keeps the display on The screen saver timeout is the amount of idle time that must elapse before the screen saver dimmer or screen saver and dimmer activates The idle time can be adjusted between 1 60 minutes The brightness intensity of the screen saver or dimmer can be adjusted between 1 100 Follow these steps to configure the screen saver using the PanelView Explorer Startup window 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the Display Input tab 4 Select a screen saver mode from the list PanelView Component Dashboard mie Traonser Heip Sign om ephyieet System informaci n Communication Terminal Secuniny Displo input Decor Eiig iness 100 LlEnabss key repeat Fairy Pepa Aute OR T Po a J Kay epesi eli Sereen saver mote me Enable Sonn ser end Cini Reboot Tecnmal Screen saver timenut 5 Callbrade Touch Serer mina A Seree
95. r will not uninstall those components because they may be used by other software packages You are required to uninstall them separately if desired The PanelView Component uninstaller removes all registry settings files directories and Windows Start menu items that were originally installed with this component see PanelView Component Extended Support Follow these steps to uninstall the emulator components 1 Go to the Control Panel under the Windows Start Menu 2 Select Add or Remove Programs and highlight PanelView Component Emulator v1 x Multiple versions of the PanelView Component Emulator can reside on the same computer A Add or Remeve Proprann Gurari Fibaka prep eri gt Maral Vela PC Or al Mec ett indios Arnal espa Yo 2 004P7 Cara rz MEDAL 4 057 chuy ETA Y eo 4 0 ary ice E Grace Chami Purine 40 70 10 RAJ fe Panes Dimjen Enmidalor wii O ber lor at ama G Power 5 7 Cy QuickTime E Phspeedy Puryer Engine FB psa Seoul sofa Token Di Same Tres 3 0 RAZ ler Pata chorra BAZ B 55P0 1 6 40 Patch 25 Front Erd RAA 3 Click Remove 4 Click Yes to confirm that you want to remove the PanelView Component Emulator Add or Remove Programs ae el Are you sure you want to remove Panelview Component Emulator v1 0 from your computer CE Publication 2711C UM001B EN P September 2008 PanelView Component Emulator Appendix C The computer goes through the removal process and sh
96. re Wizard Ther wizard helpe you rita poltware hor Allen Bradey PaneMiew USB Remote NDIS Metwork Device it your hardware came with an installation CD E on floppy disk inset i now What do you yrant the vazard to do OTTO ihe sellerie e soria Recea Ci instal irom a byt es specific location Ldwancad Check Herl bo orim Cae Ce The wizard searches for the files Found Hew Hardware Wizard Plaate mai while the wizard searches Hg Ale Brady Paneliew USB Remote HOIS Network Device E 8 If the Windows Logo Test warning dialog box is displayed click Continue Anyway Hardware Installation A The settee you are installing Don thes hardware Alla Pansies LSE Flame NDIS Hehork Devica has nal parred Wirek Logo besir do weedy ir compatbly wath Windows gt Tel me whe this tesina bs portani Continuing your installation of this softwanc may impair contact ha ferias vendo for e eto that has passed Windows Logo testing Continue Anyway STOP instalation 68 Publication 2711C UM001B EN P September 2008 Cable Connections and Communication Chapter 4 Publication 2711C UM001B EN P September 2008 The software installs Found Hew Hardware Wizard Plaate mail while the wizard inctalle the softwarea En Alen Biadiay Pared ie USE Remote HDS Network Device Ableton Cr rte ll To CINCO Sena 9 Click Finish in the Completing the Found New Hardware Wizard dialog box for the
97. return procedure www rockwellautomation com Power Control and Information Solutions Headquarters Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 2496 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automation Vorstlaan Boulevard du Souverain 36 1170 Brussels Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 100 Cyberport Road Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Publication 2711C UM001B EN P September 2008 Supersedes Publication 2711C UM001A EN P May 2008 Copyright 2008 Rockwell Automation Inc All rights reserved Printed in the U S A
98. rrent date fields Update the Current time fields Check Automatically adjust for daylight savings time if you want the terminal to adjust for daylight savings time Click Apply or click Cancel to restore the current terminal settings PanelView Component Deshna d File Transfer Help Sign OM Display input System Information Communication Terminal Secumity Firmware version In 10 Current Date Month Bool Gadi werc on Oey Year August MERA 2008 oe Logic Board version Current Time Batiery status Jont Hour Minute Second ao 33 06 Titcrtiincal cr tirri rnn uina adjust ar daigh rgi limo Tire Zone Mamor used 9 Startup Applicaton GMT 08 00 Pacte Time US E Canaria Inia TE Terminal Language English Mi Euglish Poruguds Frangais Maiani Deutsch Espa ol AibA S0 39 Chapter 2 Configuration Mode Follow these steps to change the terminal date and time from the C600 and C1000 terminals 1 Select Date and Time from the menu list Main Date and Time File Manager Communication Startup Application Display Hour Date and Time Minute System Information Second 2 Click on the number next to what you want to change A numeric keypad is displayed 3 Select the numbers you want and click the enter key Main File Manager BHH Communication oaa Startup Application HRB 2005 Display 12 Date and Time System Information
99. ry again selected in Selector Recipe Recipe S 0 Param1 failed Cause Data type of Change the type of the ingredient to match the type data point S 0 Param2 is incompatible with of the data point or select a different data point ingredient type of ingredient S 0 Param3 which matches the type of the ingredient NO Publication 2711C UM001B EN P September 2008 81 Chapter 6 Troubleshoot the System PanelView Component Terminal Alerts Category Recipe Recipe Recipe Recipe Recipe Recipe Recipe Alert Alert Alert Alert Alert Alert Alert Alert Alert Alert Alert Alert Alert 82 1021 Recipe S 0 Param1 failed Cause Unable to Check the communication settings and data point read from S 0 Param2 specification 1022 Recipe S 0 Param1 failed Cause Unable to Check the communication settings and data point read from Tag specification 1023 Recipe download failed Cause The value S 0 Correct the dataset value Param1 is greater than the maximum value S 0 Param2 allowed for ingredient S 0 Param3 1024 Recipe S 0 Param1 failed Cause Table does Restore the recipe in the table before doing a save not contain a recipe operation 1025 Recipe S 0 Param1 of recipe S 0 Try to reload the application to see if the recipe is Param2 failed Cause Recipe file not accessible still there or restore from a
100. s technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make the best use of these tools For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit http support rockwellautomation com Installation Assistance If you experience a problem within the first 24 hours of installation please review the information that s contained in this manual You can also contact a special Customer Support number for initial help in getting your product up and running United States 1 440 646 3434 Monday Friday 8am 5pm EST Outside United Please contact your local Rockwell Automation representative for any States technical support issues New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures United States Contact your distributor You must provide a Customer Support case number call the phone number above to obtain one to your distributor in order to complete the return process Outside United Please contact your local Rockwell Automation representative for the States
101. s are not supported During the import the font file is transferred from a USB Flash Drive or SD card to the internal storage of the terminal The transfer operation communicates with the terminal to transfer the file You can use the imported font in any application on the terminal TIP Fonts cannot be exported for copyright reasons Follow these steps to add a font to the terminal 1 Open the PanelView Explorer Startup window 2 Click File Transfer 3 Click New Transfer 4 Select the source location of the Font file typically My Computer and click Next 95 Appendix B Adding Font Files Remove a Font File 96 Select Font as the file type and click Next Click Browse to locate and select the Font file then click Open Select Internal Storage as the destination for the font file and click Transfer Observe the informational message for Transferring File The terminal should be rebooted to load the added font and make it available to the design environment ATTENTION If importing a font to the emulator internal storage you need to Flash Save for it to be permanently stored in emulator Otherwise it s lost once you shut down To save to internal storage select Flash and then Save from the Emulator s main window menu A font that was added to the terminal and is no longer used can be removed Follow these steps to remove a font from the terminal 1 Ze Open the PanelView Explorer Startup wind
102. s to repeat when the key is held down 7 Click Apply or click Cancel to restore the current settings To disable key repeat settings uncheck Enable key repeat Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 Calibrate the Touch Screen Over time you may notice that the objects and images on the display screen don t seem to fit the display area as well as they once did This is normal with a touch screen and can be easily fixed Use a plastic stylus device with a minimum tip radius of 1 mm 0 040 in to prevent damage to the touch screen Touch screen calibration is only supported on touch only terminals catalog numbers 2711C I3M 2711C T6C 2711 T6M and 2711 1100 Follow these steps to calibrate the touch screen using the PanelView Explorer Startup window 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the Display Input tab 4 Click Calibrate Touch Screen PanelView Component Crrshbeard File Transfer Help Sign CT Display igt Syateminfomation Comani Tenminal 5ecim try Enghinsss 100 Dl Enable kiy ropra CE Key Repeal Rati Contrast 50 5 Ki Aral Dueling Sereen saver mode Enable Screen Saver and Dimmer mer Scnetn sara linn Immi Sereen saver bighine A 5 With a stylus press the center of the target on the screen Publication 2711C UM001B EN P September 2008 31 Chapter 2 Configuration Mode
103. set the external tag to write This message is for informational purposes No corrective action needed Make sure that the recipe table is modified before the save operation is done This message is for informational purposes No corrective action needed This message is for informational purposes No corrective action needed This message is for informational purposes No corrective action needed This message is for informational purposes No corrective action needed This message is for informational purposes No corrective action needed This message is for informational purposes No corrective action needed Publication 2711C UM001B EN P September 2008 Troubleshoot the System Chapter 6 PanelView Component Terminal Alerts Recipe 1009 Recipe Download failed Cause Unable to write to Check for S 0 Param1 Communication errors Bad data point specification The ingredient value written is outside the Low EU and High EU limits of the numeric data point assigned These are optional OPC defined properties representing data point minimum and maximum values The ingredient value could not be converted to the type of the data point assigned Recipe 1010 Recipe upload completed with errors This message is for informational purposes No corrective action needed Recipe 1011 Recipe upload completed successfully This message is for informational purposes No corrective action needed Recipe 1012
104. setup process Please wait Extracting PaneNMiew Component Emulator w1 0 ma The initial splash screen announces that the installer is running It identifies the product being installed 2 Click Next to continue the installation or Cancel to cancel installation ig PanelView Component Emulator v1 0 Welcome to the InstallShield Wizard for Panehiew Component Emulator v1 0 The Iretal5heeld R Witand val instal Paneles Component Emulator 1 0 on pour computer To continua cik Next WARNING This program e probected by copyright lav ard international treaties 3 Accept the license agreement and click Next to continue with the emulator installation r gt ia Paneles Component Emulator vi 0 License Agreement Piao raed tha Folow ing kosros agreement carefully END USER LICEMSE AGREEMENT FOR COMPLIMENTARY SOFTWARE THPORTANT READ CAREFULLY This End User License i Agreement Agreement is a legal contract between you Licensee oc you and Rockwell Automation Inc Licensor foc the softuace product entitled PonelView Component Emulator the Softwacre which ig fing provided by Licensor to Licensee on a complimentary basis in AS 13 condition for Licensee s intecnol use The Softuace includes all installed e a nn E en mm rd ima Ad Pee 5 Laccopt the terme in the icense agreement de not accept tha berms in tha beers agreement 100 Publication 2711C UM001B EN P Sept
105. sion 2 as described in RFC 1112 and RFC 2236 SNMP Simple Network Management Protocol is used for internal network management and is not supported Ports 137 and 138 are normally open to support the NetBIOS protocol used by Windows CE NET similar to other Microsoft and IBM network operating systems Publication 2711C UM001B EN P September 2008 Cable Connections and Communication Chapter 4 Serial Connections Publication 2711C UM001B EN P September 2008 The terminals have a multi purpose serial RS 232 port that supports e DH 485 communication through a serial connection e DF1 full duplex communication with controllers using direct connections or modem connections e third party point to point communication The serial port on the terminal is a 9 pin male RS 232 connector The table shows the pinout descriptions for this port and how these pins map to the serial ports on the controllers m 00000 Zs Serial Port Connector Pinout PanelView Component RS 232 Port 9 pin DCE MicroLogix DNI 8 pin DIN RXD TXD DTR COM DSR RTS CTS A o o Connector Shell Chassis GND The maximum cable length for serial communication is 15 24 m 50 ft at 19 2 Kbps 59 Chapter4 Cable Connections and Communication USB Ports 60 RS 422 RS 485 Port The RS 422 RS 485 port is a nonisolated port that supports point to point communication RS 4
106. sk 255 255 254 0 Default gateway E Current Default gateway hows Fl Use DHCP Slalic IP address 131 200 55 108 Aia Subn mask 255 255 2550 Static Default gateway 131 200 55 1 AE Cs sa English Portugu s Frangais Mlaliano Deutsch Espa ol Witt CHRO 4 Uncheck Use DHCP to manually enter IP addresses 5 Enter an IP address in the Static IP address field 6 Enter the default mask in the Static Subnet mask field 7 Enter the default gateway in the Static Default gateway field 8 Click Apply or click Cancel to restore the current IP address 42 Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 Publication 2711C UM001B EN P September 2008 Follow these steps to set the IP address for the Ethernet port of the connected terminal from the C600 and C1000 terminals 1 Click Communication from the menu list 2 Click Ethernet Settings from the communication screen Main Communication Protocol File Manager Status Mot Initialized Communication Device Name PYcbho0 TEC Startup Application Mode Address Display Date and Time Ethernet Settings System Information USB Settings 3 Click Set Static IP Address Main Ethernet Settings File Manager IP Mode IP Address Communication Mask Startup Application Gateway Displa Hy Set Static IP Enable DHCP Address Date and Time System Information NS The Static IP Address screen ap
107. ssword of the system administrator Most of these settings are also adjusted from configuration mode on the terminal AB PanelView Component OUALITT lerminal Settings Hle Iranster Help Sign Of 3 ae fh AA Applications a lt iag E dis ta Mame Initial T10C Location Internal Modo Running F Display input System Information Communication Terminal Security Display inpul Devices Brightness 100 l enable key repeat 00 Color e A Key Repeal Rate lo Terminal via Ethernet oie so q A Roo O key Repeal Delay ay Screen savor mode TERESE ZEN res _ T Enable Serpan Saver and Dirarmer Febox Termal Screen Sawer tir ni dd timeout Calbrate Touch Semen Trine Sereen saver brightness 5o E Publication 2711C UM001B EN P September 2008 21 Chapter 2 Configuration Mode 22 Select a Terminal Language You can change the terminal display language The terminal is shipped with the English Portuguese French Italian German Spanish and Chinese fonts installed Korean is available but you must first install the Korean font Refer to page 72 for information on how to install the font by upgrading the firmware Follow these steps to change the terminal language using the PanelView Explorer Startup window 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the System In
108. t this controller and address Communication Server Error Communication Server Error Communication Server Error Communication Server Error Communication Server Error Check that the communication network cable is connected If new ladder logic is downloading to the controller you could see this message After the download communication should run normally Verify you have good communication to the controller If a remote device not responding alert was present then all external tags being actively scanned will generate this alert Is the address configured in the controller If so make sure all addresses of external tags to this controller are configured at the controller If one address is outside of the range a block of addresses might show this condition If the address is configured as write only at the controller this address cannot be read Set this external tag as write only and remove panel devices from your application that want to display data from this external tag Contact technical support providing this data ID1 S 0 Param1 ID2 S 0 Param2 P1 S 0 Param3 Reboot the terminal Contact technical support providing this data ID1 S 0 Param1 ID2 S 0 Param2 P1 S 0 Param3 P2 S 0 Param4 Reboot the terminal Contact technical support providing this data ID1 S 0 Param1 ID2 S 0 Param2 P1 S 0 Param3 P2 S 0 Param4 P3 S 0 Param5 Reboot the t
109. tall battery 54 SD memory card 53 USB flash drive 53 install and replace components 53 intended audience Internet Group Management Protocol IGMP 58 IP address of terminal 10 Ethernet port 11 41 USB port 11 41 K key repeat setting 30 M managing applications 50 files 50 MicroLogix cable charts 56 0 objectives operating systems 16 out of box condition 88 overview 9 P PanelView component emulator 99 PanelView explorer window 19 brightness and contrast 24 calibrate touch screen 31 change startup application 36 date and time 39 Fthernet settings 42 key repeat setting 30 reboot terminal 33 screen saver 26 system information 47 terminal security 45 peripheral connection 13 reboot terminal 33 C200 and C300 35 C600 and C1000 34 PanelView explorer window 33 recovery operations 115 remove fonts 96 replace screen saver image 29 runtime 1 S screen saver 26 C200 and C300 28 C600 and C1000 27 modes 26 PanelView explorer window 26 replace image 29 SD memory card 53 serial connections 59 RS422 and RS485 60 Simple Network Management Protocol SNMP 58 SNMP Protocol 58 specifications 91 certifications 93 environmental 92 general 91 supported browsers 16 system information 47 77 C200 and C300 48 C600 and C1000 49 PanelView explorer window 47 Publication 2711C UM001B EN P September 2008 T terminal brightness and contrast 25 calibrate touch screen 32 change startup application C2
110. ter the current user s password for the Old current user Password Alert 2041 Cannot reset password this is an unknown user Log on as one of the users defined in the application and retry Alert 2042 Cannot change password new and confirm Verify the new password matches the confirmed passwords don t match password and retry Alert 2043 Access Denied The username password is either incorrect or the user does not have the access right for the associated screen Alert 2044 Cannot run application while in Safe mode Reboot the terminal to exit Safe mode and retry Alert 2045 Cannot run applications from external storage Copy or save to internal storage and try again Alert 2046 Passwords cannot be modified while in test mode The change password and reset password devices are only enabled while in Run mode Alert 2047 File is read only Continue Choosing to continue will overwrite the read only file Alert 2048 Application has been modified Continue Edit the application and save prior to performing this operation otherwise changes to the application may be lost Alert 2050 The value is not within the minimum and maximum Enter a value within the allowable range If you do not know the range Edit the application to determine the allowable range for the device Alert 2051 Allow Autorun Press No to disallow Autorun Alert Application has been modified Allow Autorun Press No to disallow Autorun Edit th
111. tion Configuration Language nglish Portugues Francais Italiano Deutsch Espa ol EA Reset Terminal Publication 2711C UM001B EN P September 2008 Configuration Mode Chapter 2 PanelView Explorer Startup Window The PanelView Explorer Startup window lets you access the terminal through a web browser 10 2 3 Pa o i TS A 4 QUALITY i p Terminal Settings Fille Transfer Help Sign Off g an Applications ulatus Mario Initial Tic Location Internal Mode Fammi inna Tio Tenminal PanelView C600 Color Status Connected to enminal via Ethernet 9 5 Pies Aplica liar 7 English Portugu s Frangais Haliano Deutsch Espa ol MFPX tst AA 6 PanelView Explorer Startup Window Item Description 1 Terminal Settings Use this link to view and change terminal display and communication settings view system information and enable terminal security while connected to the terminal 2 File Transfer Transfers files between the storage media of the terminal and your computer You can transfer applications images fonts user defined objects and recipes You can also delete applications from terminal storage and export the alarm history log J Help Displays help for the PanelView Explorer startup window and the design time software 4 Sign off Logs you off the Startup window leaving your browser open Terminal Type and Status Shows the current connection between your PanelView Component t
112. ult wide area network protocol thal provides communicabon acioss drveise interconnected networks Show icon in notification area when connected Notify me when this connection has limited no connectivity Publication 2711C UM001B EN P September 2008 PanelView Component Emulator Appendix C Publication 2711C UM001B EN P September 2008 4 Verify that this IP address and Subnet Mask are set IP address 169 254 253 15 Subnet mask 255 255 255 0 Internet Protocol TCP IP Properties ou can gel IF selimos assigned automatically d your network supports this capability Othemase you need to ask your network administrator for the appropriate IP settings O Obtain an IP address automatically Use the following IP address IP address 169 254 253 15 Subnet mask 25 255 255 0 Delaul gateway Use the following DNS server addresses Prelened DNS server Alternate ONS server Advanc ed 105 Appendix PanelView Component Emulator Uninstall the Emulator 106 The PanelView Component Emulator Microsoft device emulator and Virtual PC programs are listed as separate items in the Windows Add or Remove Programs list If you have multiple versions of the PanelView Component emulator you can remove whichever version you want The Microsoft device emulator and Virtual PC programs are still needed by the PanelView Component emulators that remain installed The PanelView Component uninstalle
113. ystem Information screen when the terminal is in configuration mode Publication 2711C UM001B EN P September 2008 Clean File System or Clean Registry Publication 2711C UM001B EN P September 2008 Firmware Update Utility Appendix D The procedure shows how to clean the file system and the registry You can perform clean file system and clean registry operation separately or at the same time IMPORTANT Cleaning the file system removes all files including user applications Cleaning the registry only removes registry settings such as the user s selected startup application but will not remove user applications from the terminal Connect the USB host port of your computer to the USB device port on the terminal From the Start Menu select Programs gt Allen Bradley gt PanelView Component Firmware Update Utility When the utility is running make sure Clean File System Clean Registry or both are checked When you check Clean File System Clean Registry is automatically checked because the registry is a file Click the Browse button to select an SC image for example SC O1 01 002 IMG The SC image is typically obtained from the PanelView Component technical support website When a valid SC image is opened the version information is extracted and displayed Click the Begin Waiting for Connect Requests button to send the selected operations to the terminal when requested Started istenina for
Download Pdf Manuals