Home
PONA 3000 Series High Power EDFA User`s Guide
Contents
1. Fiber Amplifier a ALARM Q c Suse J O50 QO AANA ANNAN A UUUUUUUUUUUUUL WY Ortel a division of EMCORE ye amp 2015 West Chestnut Street C i L Alhambra California 91803 1542 d IN A DIVISION OF EMCORE Tel 626 293 3400 Fax 626 293 3428 www emcore com Copyright 2003 EMCORE Corporation 11 of 18 User s Guide PONA3000 UG 21069001 001 Revision B Key Features e Full Function High Power Fiber Optic Amplifier Ready for Integration Low Noise Figure Typ 6 dB e Total Input Power Range 10 dBm to 12 dBm e Total Output Power 27 dBm to 35 dBm optical output power splitter is optional for these units Standard RS 232 Communications RS 485 I C or SNMP are optional Low Electrical Power Consumption e Input Output Isolation gt 40 40 dB e Polarization Dependant Gain lt 0 1 dB e Polarization Mode Dispersion lt 0 5 ps Specifications Specifications for the PONA 3000 Series Fiber Optical Amplifier Module Table iv 1 Specifications Product Code Operating Input Power Pin dBm Max rae eee EEEE Power se se seo se wo rerea Power Consumption Max 70 50 C Case Premium 45 50 C Case Economy note 7 Hemnant pump power Nom 30 to output MWY Ortel a division of EMCORE NZ 2015 West Ch
2. Opt Out Pwr Lo Alarm or warning for low limit 3V Pwr Bad There is no settable parameter for this error condition The alarm occurs when the internal 3 3 volt power is read as either more than 0 1 volt too high or too low Keyswitch Off The keyswitch is found in the off position This alarm causes the pump to shut down 1 1 Serial Reporting of Alarms The PONA serial port is used to give the user information about the status of PONA Among this information are live updates as alarms occur or if they all go away Status information can spontaneously appear at power up and other times The serial port uses full duplex RS 232 at 19200 BAUD 2 stop bits one start bit and no parity There is no protocol and all inbound and outbound messages are viewable ASCII meant at a human rate of transfer Each time a new alarm is found to occur the following message format is sent There is a start of line prompt character either of gt followed by a space either the string ALARM followed by one space OR the string WARN followed by two spaces a 32 characters space padded right justified string describing the alarm The following are potential strings that can be sent out for different alarm conditions w Ortel a division of EMCORE SN ye 2015 West Chestnut Street SS C i E Alhambra California 91803 1542 N A DIVISION OF EMCORE Tel 626 293 3400 Fax 626 293 3428 WWW emcore com Copyright 2003 EMCORE Corporation 16 of 18
3. indicates the pump mode parameter is in OFF mode rather than constant current or power Steady Yellow minor alarm indicates that one or more parameters is near an operational limit without affecting the operation of the unit Also it can indicate the key switch is in the OFF position Flashing Yellow no alarms indicates that the laser currents fluctuates to maintain the Constant Power Mode of the PONA Red major alarm indicates that one or more parameters is outside an operational limit which can affect the operation of the PONA Laser Key ON indicates pump is enabled and can provide optical amplification The LED Switch remains yellow indicating the pump is in a steady state otherwise it can indicate the pump is dead OFF indicates pump is OFF The yellow LED is not lit w Ortel a division of EMCORE SS LL 2015 West Chestnut Street A SS C i E Alhambra California 91803 1542 N A DIVISION OF EMCORE Tel 626 293 3400 Fax 626 293 3428 www emcore com Copyright 2003 EMCORE Corporation 14 of 18 User s Guide PONA3000 UG 21069001 001 Revision B 3 Display Next Push this button to change the LCD to the next display mode If there is a current alarm this button cycles to the next of the currently active alarms Any new arriving alarms always cause the display to change If there are no pending alarms the next key allows cycling through the following live updating data e Laser cur shows
4. 21069001 001 Revision B The PONA 3000 Series includes AC DC Power Supply Front Panel Optical Splitters network card and all necessary connectors Before Initializing and Operating the Unit e Inspect the unit for any signs of damage e Read the user s manual thoroughly and become familiar with all safety symbols and instructions to ensure that the unit is operated and maintained safely Initial Inspection Warning e To avoid electrical shock do not initialize or operate the unit if it bears any sign of damage to any portion of its exterior surface such as the outer cover or panels Check that the unit and contents are complete Wear an anti static wrist strap and work in an electrostatic discharge ESD controlled area 2 Inspect the shipping container for any indication of excessive shock to the contents and inspect the contents to ensure that the shipment is complete 3 Inspect the unit for structural damage that can have occurred during shipping Note Keep the packaging Immediately inform Ortel and if necessary the carrier if the contents of the shipment are incomplete if the unit or any of its components are damaged or defective or if the unit does not pass the initial inspection Operating Environment In order for the unit to meet the warranted specifications the operating environment must meet the following conditions for temperature and humidity Temperature The unit can be operated in the te
5. After spraying a few short bursts into the bulkhead the connector is clean and ready for connection e f compressed air is not available the PONA s fiber bulkhead connector can be cleaned by 2 5 mm cotton swap or connector plate may be removed to clean the internal fiber patch cords Note CAUTION Use caution when handling fibers Do not exceed fiber manufacturers pulling tension or bend radius specifications when removing fiber bulkhead connector plate e To remove the PONA optical connector plate remove the screw on the far left of the optical plate and remove the screw on the far right of the optical plate Do not remove the screws on the optical bulkhead connector e Slowly remove the optical connector plate from the rear panel and disconnect each fiber connector from the bulkhead mounted on the plate e Clean each fiber connector Make sure the laser key switch on the front panel is in the OFF position Connect a fiber patch cord from the output of the transmitter to an optical power meter Turn the transmitter laser key switch to the ON position and use a serial port connection to make sure the parameters are set for proper operation Using the optical power meter verify the transmitter optical power is within specification Turn the transmitter laser key switch to the OFF position Remove the optical patch cord from the power meter and plug the patch cord input optical connector Connect a patch cord from the output to an optical
6. Repairs are to be carried out only by a qualified professional Do not attempt any adjustment maintenance or repair procedure to the units internal mechanism if WY Ortel a division of EMCORE WG ZA Z CD EB T L 2015 West Chestnut Street AN Alhambra California 91803 1542 AN A DIVISION OF EMCORE Tel 626 293 3400 Fax 626 293 3428 www emcore com Copyright 2003 EMCORE Corporation 4 of 18 User s Guide PONA3000 UG 21069001 001 Revision B immediate first aid is not accessible e Disconnect the power cord from the unit before adding or removing any components e Operating the unit in the presence of flammable gases or fumes is extremely hazardous e Do not perform any operating or maintenance procedure that is not described in the user s manual e Some of the unit s capacitors can be charged even when the unit is not connected to the power source Safety Symbols The following symbols and messages can be marked on the unit Table 1 Observe all safety instructions that are associated with a symbol Table 1 Safety Symbols Laser safety See the user s manual for instructions on handling and operating the unit safely A See the user s manual for instructions on handling and operating the unit safely A Electrostatic discharge ESD See the user s manual for instructions on handling and operating the i 2 unit safely Frame or chassis terminal for electrical grounding within the unit Eg Protective co
7. User s Guide PONA3000 UG 21069001 001 Revision B Laser 1 Temp Hi Laser 1 Temp Low Laser 1 Cur Hi Laser 1 Current Low Laser 2 Temp Hi Laser 2 Temp Low Laser 2 Cur Hi Laser 2 Laser 3 Temp Hi Laser 3 Temp Low Laser 3 Cur Hi Laser 3 Current Low Unit Temp Hi Unit Temp Low 5 Volt HI 5 Voltage In LO Opt In Pwr HI Optical Power Input LO Optical Power Output HI Optical Power Output LO 3v Pwr out of range Keyswitch OFF The string value appears followed by a right justified 6 character rendering of the current value that triggered the alarm event The string limits appears following by the related alarm and warning limited right justified to 6 characters each and separated by a comma and the entire alarm message is terminated by a carriage return sequence The following are some examples of alarm occurrences reported e ALARM Unit Temp Low value 21 34 limits 15 00 20 00 e ALARM Keyswitch OFF e WARN Laser Temp Hi value 26 32 limits 26 50 27 00 Note Alarms early on soon after start up can usually be ignored The string last Alarm or Warning went away appears when the final alarm present has gone away The only way to know which alarms are current at any point in time is to send the serial interface the character s This generates a list of current alarms followed by a line of pump state status Similarly the PONA serial port is used to give the user information about the PONA settings WB Ortel
8. a division of EMCORE Nw e 2015 West Chestnut Street A S C i L Alhambra California 91803 1542 N A DIVISION OF EMCORE Tel 626 293 3400 Fax 626 293 3428 www emcore com Copyright 2003 EMCORE Corporation 17 of 18 User s Guide PONA3000 UG 21069001 001 Revision B Serial Port After powered up After the PONA has been powered up the following is sent to the serial port of the PONA Enter Parameter number or hit for list e 1 Descriptor PONA 3035 2 Part number Eng Demo 3 PmpCur Setpt 1 mA 220 00 4 PmpCur Setpt 2 mA 3450 00 5 PmpCur Setpt 3 mA 3450 00 6 PmpCur Setpt 4 mA 3000 00 7 PmpCur Setpt 5 mA 3000 00 8 PmpCur Setpt 6 mA 3000 00 9 PmpCur Hi Lim 1 mA 360 00 10 PmpCur Hi Lim 2 mA 3500 00 11 PmpCur Hi Lim 3 mA 3500 00 12 PmpCur Hi Lim 4 mA 3500 00 13 PmpCur Hi Lim 5 mA 3500 00 14 PmpCur Hi Lim 6 mA 3500 00 15 EDFA Pwr Setpt dBM 20 00 16 EDFA Pwr deadB dBM 0 05 17 PmpTem Setpt C 25 00 18 PmpTem tolerance C 0 50 19 PmpTem Hi Lim e 27 00 20 PmpTem Lo Lim C 23 00 21 Pumpi Control mode CONST CUR 22 Pump2 Control mode CONST CUR 23 Pump3 Control mode CONST CUR 24 Pump4 Control mode CONST PWR 25 Pump5 Control mode CONST PWR 26 Pump6 Control mode CONST PWR 27 Pmpl Cur Hi MAJ mA 360 00 28 Pmpl Cur Hi MIN mA 350 00 29 Pmpl Cur Lo MIN mA 15509 30 Pmpl Cur Lo MAJ mA 5 00 31 Pmp2 Cur Hi MAJ mA 3500 00 32 Pmp2 Cur Hi MIN mA 3500 00 33 Pmp2 Cur Lo MIN mA 0 00 34 Pmp2 Cur Lo MAJ mA 0 00 35 Pmp3 Cur Hi MAJ mA 3500 00 36 Pmp
9. power meter oes oS Ow Turn the laser key switches on the transmitter and PONA front panel to the ON position Note Using the optical power meter verify the optical output of the PONA is within specification Note Note Difference in patch cords may result in slightly different optical power measurements 10 Turn off the key switch WZ Ortel a division of EMCORE SN ye 2015 West Chestnut Street SS C i E Alhambra California 91803 1542 N A DIVISION OF EMCORE Tel 626 293 3400 Fax 626 293 3428 WWW emcore com Copyright 2003 EMCORE Corporation 9 of 18 User s Guide PONA3000 UG 21069001 001 Revision B 11 Remove the patch cord from the optical power meter and plug the patch cord into the fiber for the link being deployed 12 Turn the key switch to the ON position General Information and Specifications The Ortel PONA 3000 Series Fiber Optical Amplifier Module is an ideal building block for OEM system integrators The family of PONA 3000 Optical Amplifiers is designed to meet the most demanding noise performance requirements of CATV and FITx applications and performs all functions required of an optical amplifier for system integration PONA 3000 Series Optical Amplifiers provide optical isolation on the input and output of the gain block for stable low noise operation The input and output optical signal power levels are detected for monitoring and control The input optical signal is amplified with act
10. 0 041 dBm ref 2 5v 2 482 Volts WY Ortel a division of EMCORE Ye amp 2015 West Chestnut Street ES i E L Alhambra California 91803 1542 IN A DIVISION OF EMCORE Tel 626 293 3400 Fax 626 293 3428 www emcore com Copyright 2003 EMCORE Corporation
11. 3 Cur Hi MIN mA 3500 00 37 Pmp3 Cur Lo MIN mA 0 00 38 Pmp3 Cur Lo MAJ mA 0 00 39 Pmp4 Cur Hi MAJ mA 3500 00 40 Pmp4 Cur Hi MIN mA 3500 00 41 Pmp4 Cur Lo MIN mA 0 00 42 Pmp4 Cur Lo MAJ mA 0 00 43 Pmp5 Cur Hi MAJ mA 3500 00 44 Pmp5 Cur Hi MIN mA 3500 00 45 Pmp5 Cur Lo MIN mA 0 00 46 Pmp5 Cur Lo MAJ mA 0 00 47 Pmp6 Cur Hi MAJ mA 3500 00 48 Pmp6 Cur Hi MIN mA 3500 00 49 Pmp6 Cur Lo MIN mA 0 00 50 Pmpo Cur Lo MAJ mA 0 00 51 I TEC 1 Hi MAJ mA 1000 00 52 I TEC 2 Hi MAJ mA 2500 00 53 I TEC 3 Hi MAJ mA 2500 00 54 I TEC 4 Hi MAJ mA 2500 00 55 I TEC 5 Hi MAJ mA 2500 00 56 I TEC 6 Hi MAJ mA 2500 00 57 Pump Tem Hi MAJ C 27 00 58 Pump Tem Hi MIN C 26 50 59 Pump Tem Lo MIN C 23 50 60 Pump Tem Lo MAJ C 23 00 61 InPwr Hi MAJ dBM 12 20 62 InPwr Hi MIN dBM 12 10 63 InPwr Lo MIN dBM 10 10 64 InPwr Lo MAJ dBM 10 20 65 OutPwr Hi MAJ dBM 21 00 66 OutPwr Hi MIN dBM 20 80 67 OutPwr Lo MIN qBM 18 20 68 OutPwr Lo MAJ dBM 18 00 69 UnitTem Hi MAJ C 60 00 70 UnitTem Hi MIN C 58 00 71 UnitTem Lo MIN C 5 00 72 UnitTem Lo MAJ C 0 00 73 InPwr Coef A 0 26 74 InPwr Coef B 0 14 75 InPwr Coef C 10 01 76 InPwr Coef D 6 99 77 OutPwr Coef A 0 04 78 OutPwr Coef B 0 12 79 OutPwr Coef C 3 19 80 OutPwr Coef D 12 40 81 Pump 1 Out Zero 0 08 82 Pump 1 Out Span 1 06 83 Temp 1 Out Zero 0 10 84 Temp 1 Out Span 1 06 85 Pump 2 Out Zero 0 07 86 Pump 2 Out Span 1 05 87 Temp 2 Out Zero 0 10 88 Temp 2 Out Span 1 05 89 Pump 3 Out Zero 0 06 90 Pump 3 Out Span 1 04 91 Temp 3 Out
12. 7 of 18 User s Guide PONA3000 UG 21069001 001 Revision B 8 Please contact the RMA department using the contact information at the beginning of this document to provide an RMA number and a shipping address Unpacking Inspect the shipping boxes for any obvious damage Unpack the unit from all packaging boxes Inspect the appearance of the unit for any shipping damage In case of damage document and inform the shipping company and your local representative EP oic c Save the shipping boxes and their inserts for any future reshipment for upgrade or repair NOTE In the event of a reshipment back to the manufacturer any additional damage caused by not using the original boxes will be considered the responsibility of the customer PONA Mounting and Power Connection Mount the unit into a 19 inch wide rack or cabinet Turn the unit power supply switch located on the rear panel off Turn the key switch located on the front panel to the OFF position p o I ox AC powered models Plug the power cord supplied with the Unit into the three prong connector on the rear panel and place the other end of the power cord into a 100 240 VAC 50 60 Hz power source e g wall socket 5 DC powered models Slightly loosen the screws labeled 48V and 48V RTN Place a wire under the screw labeled 48V RIN and tighten the screw Attach the opposite end of the wire to a ground terminal on a 48V DC power supply 36 to 60V Place a wir
13. A 3000 by customer request Optical Connectors See ordering information User specified Dimensions in inches 19 0 W X 14 76 D X 1 72 H 19 Rack Mounted IU 2U optional depending on customer request 19 0 W X 14 76 D X 3 44 H for the number of optical output ports and redundant power supply Ortel a division of EMCORE 2015 West Chestnut Street Alhambra California 91803 1542 Tel 626 293 3400 Fax 626 293 3428 WWW emcore com Copyright 2003 EMCORE Corporation NG IS CAES LET 13 of 18 User s Guide PONA3000 UG 21069001 001 Revision B Qualification e FCC Subpart B Part 15 class A Unintentional Radiators e CE EN50083 2 19995 with Amendment 1 which incorporates EN 55013 Radiated and Conducted Emissions e EN 61000 4 3 Radiated Immunity e EN 55020 Conducted Immunity e EN 61000 3 2 Harmonics All components meet Telecordia GR 1312 and GR 486 standards Except pumps in Economy Class e EN 61000 3 2 Harmonics e Fit Rate 90 level of confidence lt 2000 30 C Premium PONA 3037 90 level of confidence lt 3500 30 C Economy PONA 3037 PONA LED Alarms Table 1 1 shows the PONA controls and indicators Table 1 1 PONA Controls and Indicators Function Green no alarm indicates that adequate optical input power and output power are present Flashing Green waiting temp indicates the pump is waiting for the laser temperature to stabilize OFF configured OFF
14. EMCORE A T 015 West Chestnut Street m SS 3 E L lhambra California 91803 1542 IN A DIVISION OF EMCORE el 626 293 3400 Fax 626 293 3428 ww emcore com 3 of 18 User s Guide PONA3000 UG 21069001 001 Revision B Safety Information Power Requirements The system can operate from an AC power source that supplies 85 V AC to 265 V AC 50 60 Hz or a DC power source that supplies 36 to 60 V DC Safety Instructions The following safety instructions must be observed whenever the unit is operated serviced or repaired Failure to comply with any of these instructions or with any precaution or warning contained in the user s manual is in direct violation of the standards of design manufacture and intended use of the unit ORTEL assumes no liability for the customer s failure to comply with any of these safety requirements Before Initializing and Operating the Unit I Inspect the unit for any signs of damage and read the user s manual thoroughly I Install the unit as specified in the Getting Started section M Ensure that the unit and any devices or cords connected to it are properly grounded Operating the Unit Warning To avoid the risk of injury or death always observe the following precautions before initializing the unit If using a voltage reducing autotransformer to power the unit ensure that the common terminal connects to the earthed pole of the power source Use only the type of power cord supp
15. FA i USER S GUIDE PONA 3000 UG 21069001 001 PONA 3000 Series High Power EDFA User s Guide For more information on this and other products 1 of 18 Contact Sales at Ortel 626 293 3400 or visit www ortel com 2 of 18 User s Guide PONA 3000 UG 21069001 001 Revision B Table of Contents OLY MTOM E ON IEEE EIEE N T O E A A A E E T 3 Power mile MM MEER UU UU UU TENUES 3 BE MIS rH DIS enin A EE E A N A A ea e RENI A A p EiN M ud QR E US 3 Before Initializing and Operating the UNit cc ccccccseeceeeeeeeceeesueeceeeeeeeseesseaeeeeseeeeeeeseeaeeeesaaaeeess 3 Operating the UNIt cc eccccccssecceeeeeeeceeeeeseeeeeaeeeeeeseeeceeesaeaeeeeseeeecesseaeeeeeseaeeeessaeeeeeeseaeeeesauaeeeesagees 3 Ly VIO ears cecisc seniors ease E sent tu Itam EE E E 4 SS MIN Sasa cesta ntsc EE heath napateasetSacecmeedeaes eSeetgatetobs au EE 4 Before Initializing and Operating the Unit 5 Note Keep the DAG Ka QUIN MEN E TD TUE 5 ODS rang MVR ONION TO OTI 5 General Information and Specifications cccccccccceeecccceeeeeeeeceeeeeeeseeueeeeeeeeeeeseeeeeeesseeeeeessaeeeeesaaees 9 aic TERT TT TT mt 11 SPOCONE EE ert E dss latu DsbtuMel si cE Re MET EOM DUM 11 xa le M 12 eiecit m Tm 13 PONA CED AIIM E 13 Ee EE OM N E A E A A EAA T E A A A E 17 Ator OW Cl COM saose onei aep En E EOR EEA REEE E EEAO Ei EE 17 WW rtel a division of
16. Zero 0 11 92 Temp 3 Out Span 1 06 93 Pump 4 Out Zero 0 08 94 Pump 4 Out Span 1 06 ww Ortel a division of EMCORE amp 2015 West Chestnut Street E C E T E Alhambra California 91803 1542 N A DIVISION OF EMCORE Tel 626 293 3400 Fax 626 293 3428 www emcore com Copyright 2003 EMCORE Corporation 18 of 18 User s Guide PONA3000 UG 21069001 001 Revision B 95 Temp 4 Out Zero 0 11 96 Temp 4 Out Span 1 05 97 Pump 5 Out Zero 0 06 98 Pump 5 Out Span 1 06 99 Temp 5 Out Zero 0 09 100 Temp 5 Out Span 1 05 101 Pump 6 Out Zero 0 07 102 Pump 6 Out Span 1 06 103 Temp 6 Out Zero 0 11 104 Temp 6 Out Span 1 06 105 up steps for pwr 9 00 106 Gain Setpointl dBM 1 107 All pumps control ON 108 Delay befor pumpOn 9 When the PONA receives the character a the information similar to the following about read values will be sent out to the PONA serial port a laserlcur 229 492 mA laser2cur 3100 586 mA laser3cur 3111 572 mA laser4cur 1665 039 mA laser5cur 1701 660 mA laser6cur 1669 922 mA bk facetl 800 781 uA bk facet2 179 443 uA bk facet3 323 486 uA bk facet4 86 670 uA bk facet5 118 408 uA bk facet 180 664 uA TEC 1 cur 122 070 mA TEC 2 cur 947 266 mA TEC 3 cur 722 656 mA TEC 4 cur 344 238 mA TEC 5 cur 427 246 mA TEC 6 cur 373 535 mA lasi temp 25 160 degC las2 temp 25 116 degC las3 temp 25 008 degC las4 temp 25 464 degC las5 temp 24 791 degC las6 temp 25 029 degC unit temp 32 746 degC in power 1 583 dBm out pwr 2
17. e under the screw labeled 48V and tighten the screw Attach the opposite end of the wire to a 48V terminal on a 48V DC power supply Turn on the DC power supply 6 Turn the unit power switch to the ON position Optical Connections and Unit Verification 1 Clean all fiber patch cords before connecting Ortel a division of EMCORE FA C E T E L 2015 West Chestnut Street Alhambra California 91803 1542 N A DIVISION OF EMCORE Tel 626 293 3400 Fax 626 293 3428 WWW emcore com Copyright 2003 EMCORE Corporation 8 of 18 User s Guide PONA3000 UG 21069001 001 Revision B Cleaning Guidelines Fiber Patch cord connectors e Remove the fiber connector dust cap and wipe the fiber connector tip with a dry lint free cloth such as Kimwipes Inspect for scratches or debris on connector surface by using a fiberscope e f no scratches or debris are found the connector is now clean and ready for connection If debris or scratches are found then repeat the fiber patch cord connector cleaning guidelines Fiber Bulkhead connectors e Compressed air may be used to clean fiber bulkhead connectors Use compressed air with at least the following specifications e Non residue inert gas for precision dust removal e Ultra filtered to lt 0 2 microns e Recommended for optical systems e Using compressed air as listed above remove the bulkhead dust cover and hold the can of compressed air about 6 inches from the connector
18. ection to a standard three prong UL approved power plug PONA chassis ground lug Should be attached to chassis ground of DC 48V power supply Input Power Input power connections for 48V DC input On Off switch for DC powered units Allows the unti to be fully shut off that is no electrical power entry Fuse holder for 48V DC units Push holder in and turn 1 4 turn to the left to release fuse WY Ortel a division of EMCORE WG ZA Z CD EB T L 2015 West Chestnut Street AN Alhambra California 91803 1542 AN A DIVISION OF EMCORE Tel 626 293 3400 Fax 626 293 3428 www emcore com Copyright 2003 EMCORE Corporation 15 of 18 User s Guide PONA3000 UG 21069001 001 Revision B Table 1 2 shows the alarms and descriptions Table 1 2 Alarms and descriptions oom o Laser Temp Hi Alarm or warning for hi limit Laser Temp Low Alarm or warning for low limit Laser Current Hi Alarm or warning for high limit Laser Current Lo Alarm or warning for low limit Unit Temp Hi Alarm or warning for high limit Unit Temp Hi Alarm or warning for lo limit 5 Volt H Alarm A fixed value alarm set at 5 5 volts no warning 5 Volt Lo Alarm A fixed value alarm set at 4 5 volts no warning Opt In Pwr Hi Alarm or warning for high limit Opt In Pwr Lo Alarm or warning for low limit The pump shuts off during any time the input optical power is found to be below the low alarm limit Opt Out Pwr Hi Alarm or warning for high limit
19. estnut Street O i L Alhambra California 91803 1542 AN A DIVISION OF EMCORE Tel 626 293 3400 Fax 626 293 3428 i www emcore com Copyright 2003 EMCORE Corporation 3027 3030 3032 3033 3035 3037 NEM User s Guide PONA3000 UG 21069001 001 hee Revision B Notes Unless stated otherwise all specifications apply over the full temperature range and humidity Depending on the fibre optic patchcord interface t he measured value can vary up to 0 5 dB less than the actual value measured before splitters Measured 9 25 C and 1557 nm X Pin 0 dBm Measured with a swept Probe Signal Pp where Pp 0 dBm 25 C Measured with a swept Probe Signal Pp and a fixed Tone Signal Pt 1557 nm Pt Pp 20 dB Pt Pp 0 dBm 25 C Stability over polarization and temperature Premium version PONA with cooled Telecordia qualified pumps Economy version PONA with uncooled pumps N QUE B M Physical Physical Parameters shows the Physical Parameters Table iv 2 Physical Parameters Operating Wavelength 1545 1562 nm Standard Operating Case 0 C to 50 C Standard Temperature 40 C to 65 C Custom available by special order Storage Temperature 40 C to 85 C Standard Operating Humidity 20 to 85 Non condensing Voltage Supply Range 85 VAC to 265 VAC 50 60 Hz AC version 36 to 60 V DC DC version Redundant power supply is available for the 2U configuration by PON
20. ile a claim against the carrier is being processed Returning Shipments to Ortel Ortel only accepts returns for which an approved Return Material Authorization RMA has been issued by Ortel sales personnel This number must be obtained prior to shipping any material to Ortel The owner s name and address the model number and full serial number of the unit the RMA number and an itemized statement of claimed defects must be included with the return material Ship the return material in the original shipping container and packing material If these are not available typical packaging guidelines are as follows Wear an anti static wrist strap and work in an ESD controlled area Wrap the unit in anti static packaging Use anti static connector covers as applicable Pack the unit in a reliable shipping container AY Use enough shock absorbing material 10 to 15 cm or 4 to 6 in on all sides to cushion the unit and prevent it from moving inside the container Pink poly anti static foam is recommended Seal the shipping container securely 6 Clearly mark FRAGILE on its surface Always provide the model and serial number of the unit and if necessary the RMA number on any accompanying documentation w Ortel a division of EMCORE SS LL 2015 West Chestnut Street A SS C i E Alhambra California 91803 1542 N A DIVISION OF EMCORE Tel 626 293 3400 Fax 626 293 3428 i www emcore com Copyright 2003 EMCORE Corporation
21. ive gain control for a constant output power level or with active output power control for constant gain mode The PONA 3000 Series Optical Amplifiers also provide monitors and associated alarms for all vital characteristics The optical output of the PONA 3000 Series Optical Amplifiers can be split into several ports by an optional internal splitter The PONA 3000 Series includes AC DC Power Supply Front Panel Optical Splitters network card and all necessary connectors PONA 3000 Series Fiber Optical Amplifier Module shows the PONA 3000 Series Fiber Optical Amplifier Module Figure iv 1 PONA 3000 Series Fiber Optical Amplifier Module WZ Ortel a division of EMCORE SS LL e 2015 West Chestnut Street A SS CQ i E Alhambra California 91803 1542 AN A DIVISION OF EMCORE Tel 626 293 3400 Fax 626 293 3428 WWW emcore com Copyright 2003 EMCORE Corporation User s Guide PONA3000 UG 21069001 001 werk Revision B TH 9 1Y fo zN3 N3 o J 801 Ollooooe Q e Totje 9 ina Wao O
22. lied with the unit Connect the power cord only to a power outlet equipped with a protective earth contact Never connect to an extension cord that is not equipped with this feature Willfully interrupting the protective earth connection is prohibited Never look into the end of an optical cable connected to an optical output device that is operating Laser radiation is invisible and direct exposure can severely injure the human eye For more information see the user s manual of the laser source in use Turning off the power to the device does not always block the externally supplied radiation to the connector at the output of the unit Do not use the unit outdoors To prevent potential fire or shock hazard do not expose the unit to any source of excessive moisture Do not operate the unit when its covers or panels have been removed Do not interrupt the protective earth grounding Any such action can lead to a potential shock hazard that can result in serious personal injury Do not operate the unit if an interruption to the protective grounding is suspected In this case ensure that the unit remains inoperative Use only the type of fuse specified by the manufacturer as appropriate for this unit Do not use repaired fuses and avoid any situations that can short circuit the fuse Unless absolutely necessary do not attempt to adjust or perform any maintenance or repair procedure when the unit is opened and connected to a power source
23. mperature range of 0 to 50 C standard or 40 to 65 C for custom orders Humidity The unit can be operated in environments with up to 85 humidity non condensing 40 to 85 C Do not expose it to any environmental conditions or changes to environmental conditions that can cause condensation to form inside the unit WZ Ortel a division of EMCORE SS LL 2015 West Chestnut Street A SS C i E Alhambra California 91803 1542 N A DIVISION OF EMCORE Tel 626 293 3400 Fax 626 293 3428 www emcore com Copyright 2003 EMCORE Corporation User s Guide PONA3000 UG 21069001 001 O ORIG Revision B Warning e Do not use the unit outdoors e o prevent potential fire or shock hazard do not expose the unit to any source of excessive moisture Storing and Shipping To maintain optimum operating reliability do not store the unit in locations where the temperature falls below 40UC or rises above 85uC Avoid any environmental condition that can result in internal condensation Ensure that these temperature and humidity requirements can also be met whenever the unit is shipped Claims and Repackaging Immediately inform Ortel and if necessary the carrier if e The contents of the shipment are incomplete e The unit or any of its components are damaged or defective e The unit does not pass the initial inspection In the event of carrier responsibility Ortel will allow for the repair or replacement of the unit wh
24. nductor terminal for electrical grounding to the earth WARNING The procedure can result in serious injury or loss of life if not carried out in proper compliance With all safety instructions Ensure that all conditions necessary for safe handling and operation are met before proceeding CAUTION The procedure can result in serious damage to or destruction of the unit if not carried out in compliance with all instructions for proper use Ensure that all conditions necessary for safe handling and operation are met before proceeding Getting Started The PONA 3000 Series Optical Amplifier provides optical isolation on the input and output of the gain block for stable low noise operation The input and output optical signal power levels are detected for monitoring and control The input optical signal is amplified with active gain control for a constant output power level or with active output power control for constant gain mode The PONA 3000 Series Optical Amplifiers also provide monitors and associated alarms for all vital characteristics The optical output of the PONA 3000 Series Optical Amplifiers can be split into several ports by an optional internal splitter WZ Ortel a division of EMCORE SN ye 2015 West Chestnut Street SS C i E Alhambra California 91803 1542 N A DIVISION OF EMCORE Tel 626 293 3400 Fax 626 293 3428 WWW emcore com Copyright 2003 EMCORE Corporation 5 of 18 User s Guide PONA3000 UG
25. the laser current in mA e bk facet shows the back facet current in uA e TEC cur shows the TEC current in mA e las temp shows the temperature of the laser in degrees C e Unit temp shows the temperature of the pump case in degrees C e Out power shows the composite output optical power in dBm e Descriptor shows the 16 character configured descriptor the name of the unit e Serial number shows the 16 character factory set serial number Start up messages and the revision level of the firmware in the unit is shown as the unit powers up Display Adjust When there are no alarms and the display is showing constant cur the UP and DOWN arrows raise or lower the laser current output in the increments of 1mA Adjustments which would directly trigger alarms or cause laser current to exceed configured limits are not allowed RESET returns the either the constant power or constant current setting back to the factory preset level LCD that displays status information Can be used with Display Next button Optical Connection locations for the input fiber and out fiber with the proper type of optical connector FC APC SC APC or E2000 APC for the purchased model Serial Port Reserved for factory diagnostics Do not use without consulting technical support On Off switch for AC powered units Allows the unit to be fully shut off that is no electrical power entry Input Power IEC AC power plug with in line fuse holder for conn