WS116 ANALOG OUTPUT ADAPTER USER MANUAL
Contents
1. WARRANTY AND SERVICE Eno Scientific warrants to the user that all products manufactured by Eno Scientific will be free from defects in workmanship and materials for 1 year from the date of shipment Eno Scientific warrants to repair or replace any such defective equipment or part determined to our satisfaction to have a defect in workmanship or original material upon receipt and inspection of such defective equipment to Eno Scientific with all shipping pre paid by the user In no event shall Eno Scientific be liable for any direct indirect or consequential damages abuse acts of third parties rental equipment environmental conditions or other expenses which may arise in connection with such defective equipment This warranty shall not apply to damage of equipment caused by incorrect installation usage lightning storage alteration or inadequate care This warranty does not apply to parts assemblies or devices not manufactured by Eno Scientific which are covered by other manufacturers warranties There are no warranties except as specifically provided in writing herein Contact Eno Scientific with any warranty or service questions For additional information please visit our website at www enoscientific com
2. 20ma regulator in the output adapter will be damaged if used to regulate voltages in excess of 30V Use surge suppressors and grounding on signal lines When connecting the well sounder to remote equipment through the RS232 port or analog outputs care is required to prevent ground loops lightning induced transients etc from reaching the well sounder Over voltage and surge protectors and proper grounding should be used if this is a possibility INSTALLATION The Well Sounder probe and adapters while weather resistant are not water proof and should be mounted preferably in a covered location where they will be protected from direct exposure or allowed to lie in puddles Plug the adapter into a probe port on the well sounder Use a probe splitter if it will be used while the probe will also be required 0 5 volt installation Wiring for a 0 5 volt output requires two wires as shown below Shielded wire is not required but recommended where used in an electrically noisy environment or where the wire run may be some distance Wire gauge 28 or larger is recommended Output Device i e remote readout or data logger Vat GND 50 4 2 Output Adapter Analog Voltage Output to Well Sounder 4 20 ma installation The analog adapter is a passive or slave device meaning that the power to drive the current loop is supplied by either the target device or an external power supply The adap
3. eno A scientific STATIC WATER LEVEL MEASUREMENT WS116 ANALOG OUTPUT ADAPTER USER MANUAL www enoscientific com Eno Scientific 1606 Faucette Mill Rd Hillsborough NC 27278 USA www enoscientific com 910 778 2660 Copyright Notice Copyright 2011 Eno Scientific Hillsborough NC 27278 USA All rights reserved Part number 116 129 WS116 ANALOG OUTPUT ADAPTER USER MANUAL TABLE OF CONTENTS PRODUC T OVERVIEW ee ono lolita 4 QUICK START GUIDE a een ana 5 CAUTIONS seve 6 INSTALLATION een 7 WELL SOUNDER CONFIGURATION escent nents 9 FREQUENTLY ASKED 5 10 SPECIFICATIONS 4 4202 een 11 ADDITIONAL NOTES sinisini aiiin cosas 12 WARRANTY AND SERVICE neneseeneenennennennennennennennennennennennennennnnnennnnnennnn 13 PRODUCT OVERVIEW The WS116 Analog Output Adapter is an accessory for use with Eno Scientific s Well Sounder instruments The Well Sounders have the ability to provide user configurable output signals for high alarm low alarm or level indication This adapter contains circuitry to condition and make those outputs available for the user The Analog Output Adapter has the ability to provide an output from the well sounder as a 0 5 VDC voltage level as well as a 4 20 mA current loop signal The adapter connects to the well sounder throug
4. h the 8 pin mini DIN probe connector This requires a probe splitter to enable use of the probe and output adapter at the same time QUICK START GUIDE The output adapter is ready to go right out of the box 1 Attach the adapter to the well sounder Remove the probe from the meter and attach the probe splitter Attach the probe to one of the connectors and the output adapter to the other Make sure that the plugs are fully inserted 2 Attach the output wiring Attach the output wires to the screw terminals on the adapter observing the polarities on the label For a 0 5V output use the 2 outside terminals or for a 4 20ma current loop use the 2 inside terminals 3 Set well sounder for output Turn on the well sounder and press the SET button repeatedly until the screen displays OUTPUT Then press the UP DOWN buttons to select the output desired Then press SET again to set parameters for the selcted output type CAUTIONS The Well Sounder and adapters are not water proof They are resistant to rain and splashing but not saturation or submersion This is also true for the meter unit and the probe They will be damaged if submerged Do NOT connect external power to the 0 5V output External power applied to the 0 5V output will damage the well sounder and output adapter Care must be taken to insure that voltage spikes or induced transients are not conducted into the unit Do NOT use with a current loop source over 30V The 4
5. ter acts a throttling valve to control the current through the loop The voltage used to power the loop should not exceed 30 volts DC Output Device i e remote readout er data logger H2 or 26 or bat ost SD 4 28mA input voat am 8 5 4 28mo utput Adapter ao to Well Sounder 4 28 mA Current Loop Output WELL SOUNDER CONFIGURATION Press the SET button on the well sounder repeatedly until the display reads OUTPUT Then press the UP or DOWN buttons to select the type of output desired Select High or Low Alarm or Analog 0 5v to enable the output as well as additional setup screens Once the output type is selected press the SET button to set the parameter for the output If high or low alarm was selected then the next screen will read ALARM SETPOINT this screen is added to the set screens when the high or low alarm feature is activated Press the up or down button to select the level at which the output level is driven high If analog out was selected then the next 2 screens reads ANALOG HIGH SETPOINT ANALOG LOW SETPOINT Press the UP or DOWN button to select the range over which the output voltage will vary from 0 to 5 volts This is also converted to 4 20ma in the output adapter So for example if the Analog High is set to 100 and the Analog Low is set to 50 then the output level will be 0 volts 4ma when the depth is 50 or less and it will be 5 volts 20ma when the depth is 100 or more and
6. vary linearly in between FREQUENTLY ASKED QUESTIONS Q How far can a 0 5v signal be transmitted A In theory there is no limit However in real life factors such as induced electical noise and input impedance of the receiving device will limit the usable range A well shielded cable and larger conductors will maximize the range The input impedance of the receiving device forms a voltage divider which will drop part of the voltage across the cable resistance Larger conductors will minimize this problem Q How far can a 4 20ma signal be transmitted A The current loop is limited by the resistance of the loop The driving voltage determines the maximum resistance value Using 12 volts to power the loop the maximum loop resistance is 550 ohms At 24 volts it is 1150 ohms This resistance includes the resistance of the wire and the resistance of the receiving device So for example a typical receiving device has about a 250ohm resistance At 12 volts there would be 300 ohms available for cable resistance which for 24 gauge wire would be about 50 ohms per 1000 ft or a maximum of about 6000 ft SPECIFICATIONS POWER External Power for current loop 6 to 30VDC ENVIRONMENTAL Temperature 10 to 110 F Humidity 10 to 90 non condensing PHYSICAL Dimensions 2x2x 75 Control Unit Weight 1 6 oz OUTPUTS 0 5 volts at 20 ma 4 20 ma into 550 ohms with 12 volt supply or 1150 ohms with a 24 volt supply
Download Pdf Manuals
Related Search
Related Contents
CY-1166 printing temperature recorder User Manual Please read manual carefully before starting 製品カタログはこちら Mode d`emploi Liste des pièces détachées User ID and Password Manuel - Datatail 313112D Matrix 3 Premier Software for ADP FORERUNNER ® 405CX QUIBACSOL® commsÉ MINÉRAL AMÉLIORANT Copyright © All rights reserved.