1. 7 in 1 Talking Infrared Thermometer Model TS42S User s Manual Please read this instruction manual carefully before using your ear thermometer For a voice recorded version of this manual please visit www snotty com au products thermometers 7in1 talking thermometer Index Introduction Important Information Before Use Product Identification and Caution Description of LCD Display Setting Volume C F and Date Time Using the Thermometer Memory Recall and Deletion Battery Installation Trouble shooting Storage and maintenance Technical Specifications Warranty Contact Introduction Thank you very much for choosing this product Utilizing infrared technology this thermometer takes temperatures in seconds by measuring heat generated by the surface skin of the forehead or other objects This product conforms to the provisions of the EC directive MDD 93 42 EEC Its advantages include 1 7 in 1 thermometer Ear Forehead Talking Object Fever light bar Backlight Display Date amp Time Stamp 2 Green Red light for normal fever alert This device has the LED light to alert their readings are over 38 C 3 Illuminated Backlight Display 4 30 memory Recall 30 sets memory function amp easy to read LCD Liquid Crystal Display display give convenience all in one finger touch 5 C F Switchable Temperature reading in Celsius C or Fahrenheit F 6 Probe Cover Free The cover free probe can eliminate
2. Press Forehead thermometer mode button Using the Thermometer Measuring surface temperature A 1 Press the EAR button for 1 second to switch the thermometer on Following a successful self test the device emits two short beeps Then press the MEM and EAR buttons simultaneously for 3 seconds to switch to the Object temperature mode The symbol appears in the display Press and hold the EAR button or the HEAD button and point the sensor tip towards the object or liquid to be measured never immerse in liquids maintaining a distance of 3 cm 4 Release the EAR button or the HEAD button The end of the measuring time is signaled with a short beep and the measured value appears on the display and is spoken Please note that the displayed temperature is the measured and not the adapted surface temperature Itis not the same as the forehead ear temperature To switch back to the Ear Forehead thermometer mode press the MEM and EAR buttons simultaneously for 3 seconds until the 3 symbol disappears and there is a short beep By switching the thermometer off and on again it automatically exits the Object temperature mode N a o Press any Scan Button 12 Using the Thermometer The Readings Release the button The end of the measuring time is signalled with a short beep and the measured value appears on the display 1 lt 38 C The reading show on LCD meanwhi
3. thermometer mode On button ear LED signal red high temperature alarm green normal LCD Display Memory button Speaker Battery compartment i Sensor tip with lens cover cap removed Set button Description of LCD Display Date Time n se annn nn da Lt Lt LU Measurement in Forehead icon lt Measurement mode FC Measurement mode 2 k Object I progress symbol gt Unit of measurement C T Unit of measurement F Memory symbol and storage space T number zn E Measurement display Speaker symbol Battery warning symbol Setting Volume and Date Time LeDDisplay Press the SET button for 5 second EZN T 5 Change the setting SLT Save the setting and Confirm the entry gt Change the setting F Save the setting and Confirm the entry Date Time es 10009 0 Save the setting and Confirm the entry EZE gt Change the Month eu i Save the setting and Confirm the entry gt P x F e 5 Change the Date 21 1 2011 u Save the setting and Confirm the entry EE Ln Change the Hour 20 pil Save the setting and Confirm the entry EM Change the Min edi 20 Save the setting and Confirm the entry Save the setting Setting Volume C F and Date Time Sett
4. to Celsius 1 Press the SET button to turn the C F function on and off 2 Press the MEM button to confirm entry Setting Volume and Date Time Date Time Function Press the SET button to change 2 Press the button to confirm entry The blinking Date followed by Year Hour and Minutes will display Repeat steps 2 and 3 to adjust the date time setting 4 Your unit is now ready to take a reading or press the MEM button to turn the unit off After this process the thermometer shows the word OFF in the display and switches off automatically E lt a E Change the Year eun eit Save the setting and Confirm the entry 8 EE utt Change the Month Save the setting and Confirm the entry gt P x m E Change the Date gii Bu Save the setting and Confirm the entry Bp xf zec Change the Hour 0 Save the setting and Confirm the entry Ep redu 3293 Change the Min cot 0201 Save the setting and Confirm the entry End setting loop gt OFF Save the setting Using the Thermometer Before each use please check that the lens is intact cleaned if damaged please contact your retailer or the service address Bear in mind that the thermometer needs to have been in the room in which the measurement is taken for at least 30 minutes before use Meas
5. 3 F 131 F cf with relative humidity up to 85 non condensing Display resolution 0 1 C or F Power supply 2 X 1 5V AAA size alkaline batteries Weight 65g with batteries Dimensions 134 3mmx42 4mmx47 6mm LxWxH Warranty Full 12 months warranty from date of purchase Please save your receipt as proof of purchase cem m X 0197 Consult TypeBF device shall instruction equipment be disposed in foruse accordance with national laws after 18 their useful lives SNOTTY is proud to offer Australian parents WORK FROM HOME opportunities with the goal of improving their financial situation while promoting children s health and welfare The concept is simple 1 You purchase products from us 2 You sell them wholesale retail web sales or by hosting SNOTTY parties 3 ALL takings from sales are yours earning as much as 300 on your investment Contact workfromhome snotty com au dg Wellkang Ltd nr LONDON U K Manufactured for Perpetus Pty Ltd Australia ABN 49 142811 069 Made in China SNOTTY P O Box 111 Labrador Qld 4215 Australia web www snotty com au email info snotty com au 72 T42MN 031
6. flashes K gt and Lo appears in the display the batteries must be replaced If the batteries are too flat then the thermometer will switch off automatically NOTE When changing the batteries use 1 03 10 38 et 3rn 200 0 6 e batteries of the same type and capacity Always replace both batteries at the same time Do not use rechargeable batteries Please use batteries free from heavy metals pull the lid off downwards Loosen the screw on the battery compartment lid and 2 Remove the used batteries and insert two new AAA batteries in the direction indicated 3 Place the battery compartment lid back on and screw it closed Dispose of used batteries in accordance with the applicable local regulations Never dispose of batteries with your normal household waste 15 Trouble shooting When a malfunction or incorrect temperature measurement occurs an error message will appear as described below comes with backlight and voice prompt 0 C 32 0 F LCD Display Cause Solution The temperature Operate the measured is higher thermometer only than between the specified 1 Ear Forehead temperature ranges If thermometer mode necessary clean the sensor tip rm 50 122 0 F h ip 2 Object In the event ofa temperature mode repeated error 100 C 212 0 F message contact your retailer or The temperat
7. he thermometer on Following a successful self test the device emits two short beeps 2 Remove the cap by gently lifting the front of cap upwards 1 while simultaneously pulling it off forward 2 UN 3 Make sure that the sensor tip and also the ear canal are clean As the ear canalis slightly curved you have to pull the ear slightly up and backwards before inserting the sensor tip This is important so that the sensor tip can be pointed directly at the eardrum A 4 Insert the sensor tip carefully and press the EAR button for 1 second Release the EAR button The end of the measuring time is signaled with a short beep and the measured value appears on the display and is spoken a Using the Thermometer Measuring body temperature on the forehead 1 Please note that the forehead temples must be free from sweat and cosmetics and that taking medication and skin irritations can distort the result when measuring temperature on the forehead 2 Press the HEAD button for 1 second to switch the thermometer on Following a successful self test the device emits two short beeps Place the measuring head with the forehead cover cap fitted on the temples hold down the HEAD button and move the thermometer smoothly over the forehead to the other temple 4 Then release the HEAD button The end of the measuring time is signaled with a short beep and the measured value appears on the display and will be spoken
8. ing Volume The unit in which the temperature will be displayed the date and the time When the thermometer is used for the first time and each time the batteries are changed the date and time are displayed in the format 1 1 00 00 during the basic set up after the self test Set each of the following settings in turn volume unit in which the temperature will be displayed date and time To set the device proceed in stages Volume U01 lowest setting U06 highest setting Unit year month day hours minutes there is no voice output when setting date and time 1 Press the SET button for 5 second to switch the thermometer on The device performs a brief self test all elements of the display are shown for approx 1 second Following a successful self test the device emits two short beeps In Standby mode the date and time are shown and is displayed 2 Turn the device on and the speaker symbol shows whether the Volume function is on or off Press the SET button to turn the Volume function on and off When you turn the voice function on a short beep sounds speaker symbol visible 7 voice function on speaker symbol not visible 7 voice function off Press the SET button to change the volume VOL 01 e VOL 02 VOL 03 una VOL 04 n3 VOL 05 unc VOL 06 uua inb 3 Press the MEM button to confirm entry Setting Volume C F and Date Time Changing from Fahrenheit
9. le the backlight and alert light green will light for 3 sec and then the voice will pronounce the temperature 2 238 C The reading show on LCD meanwhile the backlight and alert light red will light for 3 sec and then the voice will pronounce the temperature Green Normal lt 38 C lt 100 4 F 9 When talking on The Voice Sentence Ear your body temperature is 36 5 C Forehead your body temperature is 36 5 C Object the object temperature is 36 5 C d When Talking OFF The light indicator shows only for 3 seconds 13 Memory Recall and Deletion Memory Recall You can recall up to 30 measurements plus an average of all currently stored measurements in memory to share with your physician or trained healthcare professional 1 Press the MEM button The first reading 28 0 36 displayed is the average of all 9 measurements stored in memory m al al Jt a S 2 Continue to press the MEM gg 1 21 button to view the next 9 cl previously stored Ww i measurement anc 42 Bi ihe Note The memory bank can store up to 30 readings When the number of readings exceeds 30 the oldest data will be replaced with the new record 14 Battery Installation When the batteries get weak the battery warning symbol It is still possible to measure temperature The batteries must be replaced When the battery symbol
10. ontact with the lens No modification of this equipment is allowed 115 recommended to take 3 temperature readings If they are different use the highest reading as indicated temperature Do not expose the thermometer to extreme temperature very high humidity or direct sunlight Avoid extreme shock or dropping the device Before taking a temperature measurement make sure that both the thermometer and the patient object have been in the specific environment for at least 30 minutes 9 Avoid measuring temperatures within 30 minutes after exercise bath or change of environment 10 To protect the environment dispose of empty batteries at appropriate collection sites according to national or local regulations 11 Do not disassemble the thermometer 12 Please use the thermometer solely for its intended purpose 13 Carefully hold the device when in use to avoid dropping the device 14 Allow one minute between successive measurements as slight variations may occur if measurements are taken over a short period of time Use average temperatures instead 15 Keep reliable records of your personal temperature to serve as a reference for your health professional 16 The temperature taking result is ONLY a reference Before taking any medical action please consulta health professional ORO o oN 2 Product Identification and Caution Forehead cover cap Forehead thermometer mode button forehead Ear
11. the problem of transmission deviation due to the cover s material and is as such more accurate 7 Waterproof Probe Design Waterproof probe enables easy cleaning and usage 8 One second Reading 9 Power Saving Auto Power Off Auto power off after 30 second idling to ensure longer battery life 10 Low battery Indicator 11 Warning indication low battery symbol and Lo Hi symbol indicating out of measuring range or low battery 12 Large LCD Display Easy to read large LCD display 13 Large Button Design For easier operation 14 Economic design and convenience This is a Non contact medical thermometer that enables temperature readings in ear object or subject forehead 15 Accurate and Reliable 16 Compact Small and light design is ideal for home use and traveling 17 User Friendly Due to our unique design of the measuring software users don t need to have special skill to operate this device 18 Instant Measurement By using our unique technology users can get their precise body temperature accurately in 1 second 19 Conveniently powered by two AAA batteries 1 Important Information Before Use When using this product please be sure to follow all instructions listed below Failure to follow these instructions may affect the accuracy of the thermometer and cause injury 1 Do not disassemble repair or remodel the thermometer 2 Be sure to clean the thermometer lens before and after each use Avoid direct finger c
12. ure Customer Services measured is lower than 1 Ear Forehead thermometer mode X 10 C 50 0 F 2 Object temperature mode Err The operating temperature is not in the range from 16 C 35 C 60 8 F 95 F Operate the thermometer only between the specified temperature ranges d When talking on Prompt measurement error please try again 16 Storage and maintenance Clean the probe and tip with an alcohol swab before and after each measurement s Use a soft dry cloth to clean thermometer body Never use abrasive cleaning agents thinners or benzene for cleaning Do not scratch the surface of the probe lens orthe display Do not expose the thermometer to extreme temperatures humidity direct sunlight or shock Store at room temperature dig Technical Specifications Range of Measurement Body Temperature 10 C 50 C 50 0 F 122 0 F Object Temperature 0 C 100 C 32 0 F 212 0 F 1 Measuring accuracy Ear 0 2 C 0 4 F from 35 5 C to 42 C 95 9 F to 107 6 F 0 3 C 0 5 F outside the range Forehead 0 3 C 0 5 F from 22 C to 40 C 71 6 F to 104 F 4 Object Temperature 30 C 1 5 C gt 30 C 5 in 3cm Operating environment 16 C 35 C 60 8 F 95 F with relative humidity up to 85 non condensing Storage Transportation environment 25 C 55 C 1
13. uring body temperature in the ear 9 i Some people produce different readings in their left and right ear In order to record temperature changes always measure a person s temperature in both ears and use the higher reading The ear thermometer may be used by children only under adult supervision Measurement is usually possible over the age of 6 months In infants under 6 months the ear canal is still very narrow so the temperature of the eardrum often cannot be recorded and the result displayed is often too low The measurement must not be taken in an ear affected by inflammatory diseases e g discharging pus or secretion after possible ear injuries e g eardrum damage or in the healing period after operative procedures In all of these cases please consult your health professional Use ofthe thermometer on different persons can be inappropriate in the event of certain acute infectious diseases because of the possible spread of germs despite cleaning and disinfection If you have any doubts please consult your health professional This thermometer should be used without a disposable protective cover If you have been lying on one ear for some time the temperature will be slightly higher in that ear As ear wax can affect the measurement you should clean the ear before measuring if required 9 Using the Thermometer Measuring body temperature in the ear 9 1 Press the EAR button for 1 second to switch t