FIREPLACE OS (RT-08G-OS)

image

Contents

1. Before each opening the door the air damper should also be opened by pressing 4 in order to avoid the smoking After lighting the fuel and closing the door you must again press 4 to restart the combustion process Reaching the embers phase F8 is accompanied by a broken sound signal switch off with the button CONFIRM 6 blinking number of the phase with the flame symbol and blinking of the green diode 8 which indicates the need for replenishing the fuel in case of continuing the heating The control unit can run in the automatic or manual mode The longer pressing F2 8 about 2secs causes the pass to the manual mode The CHOOSE button 7 causes the next screens to be called up 3 3 Screen of the MANUAL operation of the fireplace The transition to the MANUAL mode the status LED diode 1 blinks enables taking control of the combustion process The air damper opens up 100 From this moment you can manually control the air damper the button 5 causes shutting 1 step 10 and the button 4 causes its opening With the button F2 8 you can cyclically change the controlled circuit to switching on the circuit that increases the chimney draught relay CONTROL ALARM and once more the air damper The selected circuit blinks on the display Same like for the air damper with the button 4 you switches on and with the button 5 you switches off the selected circuit In the MANual mode you must not fully cl
2. PARAMETERS CAN BE CHANGED ONLY AT UNLOCKED PASSWORD Setting I Setting the valtieof ON causes thie xecall of all parameters to value of ON causes the recall of all parameters to RESET ach their default pre sets and restarts the control unit 92 PASSWORD 0 9999 0000 0000 PASSWORD OFF sn PASSWORD ON Service OFF OFF The ON value causes diagnostics screen to be added Screen ON for servicing Parameter number only plays an auxiliary role It s used to unambiguous identification of the parameter name e g for different language versions Password The changes of important parameters are possible only at unlocked password To unlock the password you need to input proper sequence of digits with the buttons With the CHOOSE button 7 to change the digits position and CONFIRM button 6 to acknowledge all and finish the procedure of changing the password The unlocked password is set to 0000 Once again entering into the password change procedure causes a new password to be set PASSWORD 9999 HAS CONSIDERABLE MEANING IT CAUSES THE REACTIVATION OF THE PREVIOUS PASSWORD IF PRESENT WITHOUT IT BEING EXPOSED PASSWORD OF PRODUCER S SERVICE IS UNIQUE AND IS NOT DEPENDENT ON THE USER S PASSWORD IT SHOUDN T BE EXPOSED TO THE USER INSTEAD OF THAT THE SERVICE CAN SET TO THE USER HIS OWN PASSWORD Examples of passwords 1 The control unit is installed with the unlocked password The user can enter his own passw
3. of CO concentration increases the safety of a fireplace user The control unit is equipped with its own emergency power supply The pause in power supply up to 8secs doesn t affect control unit operation because during that time the buffer power supply switches on If the pause is longer the air damper opens up in emergency and then the control unit switches off Advantages of the combustion optimizer lowering the maximum combustion temperature extending the combustion process decreasing fuel consumption extending the exploitation time of fireplace inputs shutting off air supply after ending the combustion preventing the furnace cool off optimal use of the heat accumulation module cooperation with CO sensor opening up the fresh airing in emergency the control unit can limit the maximum temperature of the combustion CHIMNEY FIREPLACE PP Fig l Basic operation scheme of the control unit T1 Temperature sensor of the combustion D1 Sensor of opening the furnace door option PP Controllable air damper 2 Admission date Realization date Signature Remarks TANINAN A Y R L N PRODUCENT ZASILACZY SIECIOWYCH ISO 9001 2000 CE CONFORMITY DECLARATION Ref No 58 RT 01 2007 1 B We ZAK AD ELEKTRONICZNY TATAREK Jerzy Tatarek 75 Swieradowska St 50 559 Wroclaw declare under our sole responsibility
4. off ea Ed Wi B Chimney draught ON switched on Type of the circuit 1 3 MAC 4 draught generator Sensor CO OFF no danger By pressing the button CHOOSE 7 you go over the next screens 3 5 Screen of setting the parameters Th first screen shows Parameters level 0 which means the parameters aren t available After changing the level to 1 2 3 or 4 the successive screens show the values of parameters The last screen contains after which it comes back to the above mentioned screens Parameter name Upper and lower TE Parameter value limit of changes change PARAMETERS ADAPT THE CONTROL UNIT TO THE PROPERTIES OF THE FIREPLACE THEIR CHANGE SHOULD BE CONSULTED WITH THE PRODUCER OF THE FIREPLACE INCAUTIOUS CHANGES CAN CAUSE UNSTABLE AND INEFFICIENT OPERATION OF THESYSTEM PARAMETERS LEVEL 1 FUNCTION The click of buttons is off Sound alarm is off NAME aia The click of buttons is on Sound alarm is off ON ALARM The click of buttons is on Sound alarm is on Signal OFF ON ON ON AL ALARM OFF ALARM The click of buttons is off Sound alarm is on ee polski polski iii clase version english deutsch ial a OFF OFF a aa of the display is active for 2min since backiiett ON last pressing the button ON Backlight is active constantly if the control uni
5. that the product Combustion Optimizer model RT 08G OS is in conformity with the basic requirements included in Directive EMC 2004 108 WE of 15 12 2004 the electromagnetic compatibility law of 13 04 07 and Directive LVD 2006 95 WE of 21 08 07 Laws Journal of 2007 No 155 pos 1098 regarding the requirements for electric devices To the conformity evaluation the following harmonized standards were used PN EN 60730 2 1 2002 Automatic electric regulators for house usage and the like Part 2 1 Specific requirements regarding electric regulators for electric house devices Automatic electric regulators for house usage and the like Part 1 General requirements PN EN 60730 1 2002 PN EN 55022 2000 Electromagnetic compatibility EMC IT devices Characteristics of radioelectric noises Acceptable levels and measurement methods Complementary information Laboratory IASE 51 618 Wroclaw 1 Wystawowa st 39 DL 1 07 of 22 06 2007 41 DL 1 07 of 03 07 2007 Test report No Electronic Engineering Plant TATAREK has initiated management system and complies with the following standard ISO9001 2000 CERTIFICATE No 133 2004 of 01 2004 Polish Foreign Trade Chamber The last two digits of the year in which the CE marking was affixed 07 Place of issue Manufacturer representative Wroclaw Miros aw Zasepa Lage Date of issue Position 08 2007 Designer 2 1 Operation phases of the control unit 1 Fstop Standby phase The c
6. AC Heat Accumulation Module During the heating up phase when the fireplace is cold its draught can be insufficient The control unit can control the system of increasing the chimney draught with the K1 output To this output you can connect a actuator of the by pass flap MAC or draught generator Depending on the applied actuator and the paramater lt 50 gt K1 MODE we ve got the following possibilities Version 1 Temp C u psnnnnnnnnny a a a wy ta a a a K1 n Pj ta Q a i Q es cnimne Q t ta d a 2 e e o O o O o e ta K1OfF MAC a F1 Fstop The parameter lt 50 gt K1 MODE 1 In the standby state the output K1 is switched off The flap is directed towards the MAC The start of the combustion causes turning on the output K1 and directing the combustion gas directly to the chimney After reaching the preset temperature lt 51 gt Temp Flap K1 the flap is switched off and it directs the gas to the MAC Version 2 A Temp C K1 On K1 On TTT nen B E 5 a z chimney Fg chimney a lt 51 gt Temp K1 Bag a re i a com ae K1 Off MAC eat F1 Fstop The parameter lt 50 gt K1 MODE 2 In the standby state the output K1 is switched on The flap is directed towards the chimney After reaching the preset temperature lt 51 gt Temp Flap K1 the flap is switched off and it dire
7. Fig 3 Wiring scheme PP Electronically controlled air damper TATAREK X3 Input to connect a control device of CO concentration The input has higher potential it s important for Open Collector Systems Schort circuit of the contacts means the exceeding of permitted CO concentration At the lack of CO control you leave the contacts not connected D1 Sensor of opening the furnace door By the open door the contact D1 should be short circuited By the closed door the contact D1 should be opened out acc to the figure Tl Sensor of combustion temperature Thermocouple type K the wire of higher potential is green of lower one is white K1 Flap drive of the by pass of the heat accumulation module or draught generator option Version 4 Temp C snnm ss haag a oy a a t a a a Q t Q a a t Q t on nd a a a a a e e a e 2 e a a a a a a ta a a Seeman lt 52 gt Time K1 The parameter lt 50 gt K1 MODE 4 The fan of the draught generator is connected to the output K1 The generator switches on after opening the fireplace door the sensor of opening the door 1s needed and switches off after 1min The parameter lt 52 gt Rundown Time of K1 since closing the door 2 6 Additional functions of the control unit lAn external device controlling CO concentration can be connected to the control unit In case of d
8. WARNING WE INFORM THAT THE OFFERED CONTROL UNIT CAN BE ONLY APPLIED TO THE FITTING DEVICES THE REQUIREMENTS OF THE TECHNICAL AND BUILDING STANDARDS CONCERNING THE CORRECTNESS OF STOVE AND HEATING SYSTEMS HANDLING THE FIREPLACE INPUTS MUST BE MET WRONG USAGE OF THE CONTROL UNIT CAN LEAD BOTH TO ITS DAMAGE AND IN EXTREME CASES TO THE DAMAGE OF THE FIREPLACE INPUT AND HEATING SYSTEM CONTROLLED BY THE FIREPLACE AS WELL ALONG WITH THE DEVICES THAT COOPERATE WITH THE HEATING SYSTEM WARNING We inform that in case of systems based on the water cap you should pay attention to the location of mounting the temperature sensor of water in the cap Because of high temperature maintaining close to the water cap and coming from that both a risk of damaging the sensor and false measurements of temperature its assembly should be carried out on the pipe channelling water from the water cap beyond the fireplace INIA Zak ad elektroniczny TATAREK Jerzy Tatarek 50 559 Wroclaw 75 Swieradowska st ph 071 367 21 67 373 14 88 fax 373 14 58 Tax index number 899 020 21 48 Bank account BZ WBK S A WROCLAW 6910901522 0000 0000 5201 9335 www tatarek com pl E mail tatarek tatarek com pl WINANS RT08GOS 2012 v 1 0 ANG Zak ad elektroniczny TATAREK Jerzy Tatarek USER MANUAL v 1 0 27 01 2012 program version from 1 0 FIREPLACE OS RT 08G OS COMBUSTION OPTIMIZER FOR THE FIREPLACE WITH ACCUMULATION MASS 1 Basic
9. companied by a broken sound alarm that can be turned off by pressing the button F2 The CHOOSE button 7 causes the next screens to be called up 3 2 Screen of the automatic operation of the fireplace The screen enables the control of the control unit operation A theoretical combustion curve 1s presented on the display in 2 versions the first concerning the full combustion and the second one concerning the partial combustion that is when the drop of temperature before the phase F6 occured during the combustion process The blackened phase numbers indicate the history of combustion process Combustion F1 switching off Operation curve the control unit phase SS ae ENE 350 ee F2 MANUAL operation Combustion Current phase temperature of the operation Opening of the air damper In the automatic mode each opening of the door causes the air damper to be set at 100 and each shutting of the door causes the combustion process started and the diode 1 lights If the furnace is cold then after the time lt 22 gt lt 24 gt see the parameters the control unit closes the air damper and passes to the standby state Likewise the control unit acts when the power turns on During the operation without the sensor of the door the panel buttons are used for controlling Pressing 4 causes opening the air damper and starting the cycle
10. cts the gas to the MAC After the combustion the K1 output is switched on The flap is again directed to the chimney Version 3 A Temp C eeetettnnaa aa 1a a ay a es ta a e lt 51 gt Temp K1 a a a a a a a a a a a a a a a a a a a a a a a a a a a ay a KIO K1 Off chimney i chimney aS P annu gt Time F1 Fstop imin The parameter lt 50 gt K1 MODE 3 In the standby state the output K1 is switched off The flap is directed towards the chimney After reaching the preset temperature lt 51 gt Temp Flap K1 the control unit switches on the K1 output causing redirecting the combustion gas to the MAC After the combustion the K1 output is switched off The flap is again directed to the chimney WARRANTY 1 Warranty is valid 24 months from the date of sale 2 Producer does not take responsibility for any mechanical damages made by user 3 MAKING REPAIRS OR MODYFYING THE RT 08G OS CONTROL UNIT BY USER IS FORBIDDEN AND CAUSES WARRANTY CANCELATION 4 Warranty card is valid only with date of sale seller s signature and stamp 5 Warranty and after warranty repairs should be done only by producer damaged control units should be sent to producer in order to make all repairs needed 6 Warranty protection involves the EU 7 Warranty does not exclude not restrict and not suspend buyer s rights coming from the incompatibilit
11. etecting the danger the air damper opens up improving the ventilation of room additionally the signal alarm switches on The control unit switches on the ALARM output in case of damage of the temperature sensor of the furnace T1 or exceeding of CO concentration 3 Operating the control unit There are elements on the control panel fig 2 In the turn off state only the orange stanby state LED 7 lights and the graphic display shows current temperature of the fireplace The air damper is open and the outputs switched off The turn on of the control unit follows by pressing the button ON OFF F1 3 In order to turn it off press once more the button 3 and at the same time hold it down for about 1sec At the turned on control unit the F1 button can have additional meaning if there s an icon showing up atit In case of supply voltage decline the control unit comes back to the state before the decline The operation state is presented on the graphic display 2 The screens inform about the operation of devices temperature of sensors they make it possible to change the parameters etc The change of screen is done by pressing the CHOOSE button 7 If this is the screen that is able to change a parameter press the CONFIRM button 6 which causes blinking of the parameter field to be changed By pressing 4 or 5 one can alter its value By clicking the CONFIRM button 6 one confirms the changes the parameter fie
12. hase F6 pe eee ey eee Temperature drop in relation to the maximum one in F6 indicating the start of the phase F7 35 Temp 50 1250 C 460 C Temperature of starting the phase F8 embers phase Slem ee ee 36 Temp 320 C Temperature of starting the phase F8 embers phase in F8min case the maximum temperature was reached in F3 F4 or F5 no phase F6 37 Timeof F8 1 720min 10min Time span ofthe phase FS eee een TE __ pent tert bring down eat gases Opening the air damper and burning down the exhaust gases 144 CVS F4 0 100 60 air damper opening at the start of the phase F4 145 CVS F5 0 10 75 air damper opening at the start of the phase F5 CVS F6 0 100 90 air damper opening at the start of the phase F6 CVS F8 0 100 10 airdamper opening at the start of the phase F8 CVS ChokeV State F PARAMETERS LEVEL 3 l PARAMETERS CAN BE CHANGED ONLY AT UNLOCKED PASSWORD FUNCTION 50 a 1 System type of increasing the chimney draught K1 K1 MODE see ch 2 5 Flap MAC Draught generator E Combustion temperature causing the switch over of the by pass flap Switch on of the MAC block at the option Flap K1 lt 50 gt 1 3 see ch 2 5 52 Rundown 0 20 mi 1 min Time span of operation of the draught generator after mea A a a a see ch 2 5 ee tet oe Switching on the relay CONROL if Rela alarm situation occurs J Alarm situation is ac
13. ld stops blinking The changed parameter not confirmed for 30 secs is not accepted by the control unit and it recalls a previous value of the parameter The button F2 ESC 8 causes cancelling the current operation and going over to the screen of control unit operation the F2 button can have additional meaning if there s an icon showing up at it 5 ON OFF Dova CHOOSE CONFIRM Fig 2 View of control panel l ea ae e Status LED diode of the control unit o emergency alarm red o standby orange o operation green o manual operation MANUAL the green diode blinks Graphic display Button F1 ON OFF Button to increase a value Button to lower a value Button to confirm changes Button to choose a parameter Button F2 ESC 3 1 Alarm screen Alarm screen is not seen till the following emergency situation takes place 1 Damage of the sensor T1 The text Fplace temp sensor T1 damaged shows up 2 Damage of the internal sensor of the reference temperature The text Temp error T0 shows up 3 Exceeding of the limit concentration of CO by short circuiting the contacts X1 The text GAS shows up 4 Exceeding of the maximum temperature of the fireplace The text Too high temp of the fireplace shows up Alarm content F1 Switching off the control unit F2 Switching off the alarm signal PARAMETERS LEVEL 4
14. meters The serviceman locks the control unit with his secret password which removes the user s password and locks the control unit 6 Serviceman doesn t have to know the user s password Always he can use his own secret password and at the end lock with the 9999 which reactivates the user s password JJ PARAMETERS LEVEL 2 PARAMETERS CAN BE CHANGED ONLY AT UNLOCKED PASSWORD o Maximum temperature of the fireplace After exceeding Fireplace 400 1300 C 1300 C it the alarm turns on and the air damper closes to the value defined by the next parameter lt 21 gt The default 1300 C indicates the function is not active 21 ChokeV 10 50 30 Air damper opening when the temperature exceeds state T MAX T max Time of F1 15 600s 60s Delay of control start time span of the phase F1 23 Temp 10 1250 C 45 C Restart temperature after switching on the power RESTART If after switching on the control unit the temperature in the furnace is higher than Temp RESTART then an automatic restart follows Time STOP After this time the transition to the standby state STOP a follows if the temperature Temp RESTART is not Temp F3 30 1250 C 200 C Temperature of starting the phase F3 reached Temp F4 50 1250 C 410 C Temperature of starting the phase F4 Temp F5 50 1250 C 600 C Temperature of starting the phase F5 Temp F6 59 1250 C 700 C Temperature of starting the p
15. ontrol unit awaits opening the door and preparing the fuel for the next heating In the STOP state the air damper is closed 2 F0 Temporary state after switching on the power at the closed door The air damper is open Depending on the temperature of the furnace the control unit decides if it has to go to the standby phase Fstop or to continue the process of combustion F1 3 F0 State after opening the furnace door The air damper is open 4 F1 Start phase After loading the fuel and its lighting you close the furnace door It s a signal for the control unit that the combustion cycle has begun The air damper is fully open 5 F2 Heating up phase After reaching the limit temperature the pass to the phase F3 follows 6 F3 4 5 Phases of temperature increase The air damper is set depending on the temperature according to the combustion curve F6 Burning phase Awaiting the maximum combustion temperature of the process F7 Phase of decreasing temperature The air damper is gradually closed F8 Embers phase Signalling the demand for replenishing the fuel F9 Phase of removing the exhaust gases The air damper first opens up and then closes and there s the pass to the standby phase oo oe ai The control unit can control the fireplace without the opening sensor of the door In that case the keyboard buttons are used 2 2 Sensor of combustion temperature Sensor of combustion temperature is a thermocouple type K which can mea
16. ord e g 1234 From this moment the important parameters cannot be altered without the password being unlocked that is resetting the password 1234 After changing essential parameters the user can leave the control unit unlocked set any new password or enter 9999 which activates the password 1234 2 Producer gives the control unit with the set password The user cannot alter the important parameters The servic can change the settings with its own secret password At the end a serviceman enter the secret password or 9999 the user still hasn t access to the important parameters 3 Producer gives the control unit with the set password The user cannot alter the important parameters The servic can change the settings with its own secret password At the end a serviceman leaves the control unit unlocked the user now has access to the important parameters He can enter his own password like in example No I 4 Producer gives the control unit with the set password The user cannot alter the important parameters The servic can change the settings with its own secret password At the end a serviceman sets the password e g 1234 and tells it to the user the user has access to the important parameters but without knowing the password the other persons cannot make the changes 5 The user has the unlocked control unit or his own password Serviceman decides the user though oughtn t have access to the important para
17. ose the air damper before reaching the embers phase because there s real danger of increasing CO concentration Combustion temperature F1 Comeback of automatic operation Opening the air damper ra aa ra ra ra tar aq F2 change of control chimney ene draught CONTROL ALARM The comeback of the automatic mode is initiated by pressing the button F1 3 By pressing the button CHOOSE 7 you go over the next screens 3 4 Screen of combustion history This screen shows the history of combustion The screen isn t visible if the fireplace operates in the manual mode MANUAL The start of registration follows with the start of the phase F1 and the end of registration after F9 The temperature is registered every 50secs The start of registration begins from the temperature 0 C which constitutes the marker of the new cycle of combustion see the fig below Combustion temperature Current cycle of lt uanuannnnny combustion Previous cycle of combustion Marker of new cycle By pressing the button CHOOSE 7 you go over the next screens 3 5 Information screen x ensor of the door This display informs about the state of the circuits OFF open connected to the control unit Relay CONTROL ALARM O OFF switched
18. sure the range 0 C 1300 C The sensor should be mounted over the exhaust gas output from the furnace 2 3 Limiting the maximum temperature of combustion For the fireplace inputs whose construction requires limiting the maximum temperature of combustion it s possible to program the limit Exceeding the temperature defined by the parameter lt 20 gt Fireplace T MAX causes that the air damper closes to the level of 30 parameter lt 21 gt ChokeV State T MAX and the alarm turns on The process of shutting the air damper begins at 50 C before reaching that limit Turning off the alarm and the return of normal operation of the air damper follows if the temperature decreases again The default 1300 C practically indicates that there s no limit it s the maximum temperature of operation of the temperature sensor 2 4 Air damper The air damper is mounted on the input of cold air to the combustion chamber The position of the air damper is calculated by the control unit depending on the combustion process The change of the position is carried out by the drive of the air damper in 20sec cycles In the turn off state also the decline of the power the combustion process is not controlled In order to prevent CO concentration increase in case of the partial combustion before reaching the embers phase the air damper is opened 2 5 Increasing the chimney draught During normal operation the heated exhaust gases cool off flowing through the M
19. t 1s switched on Switching off the backlight indicates it assumes the value of the next parameter lt 14 gt 0 25 10 Minimal value of the backlight MIN LCD it s important for the negative display Value 0 backlight indicates a full switch off 15 Registartion 1 6h 2h Registration time of combustion history Time At 1 hour temperature registration every 40s At 2hrs every 2 40s and so on
20. technical parameters Power Power consumption without load Maximum connection power Operation conditions Housing protection class Fuse Number of outputs to control the pumps Number of nonvoltage control outputs Number of outputs to control the air damper drive Number of water temperature sensors Temp measurement precision Temp measurement resolution Number of time zones 230V S50Hz SW 750W 0 50 C humidity 10 90 no condensation IP41 6 3A 250V 3 250W 230V 50Hz l 1 SV S500mA DC 3 KTY81 0 100 C 2 C 0 5 C 4 2 Principle of operation With the air damper the control unit controls the combustion process and maintains the embers phase By lowering the combustion curve in the phase of increasing temperature and by raising it in the phase of decreasing temperature the control unit extends the combustion process The control unit starts operating as the furnace door closes sensor of opening the door supervises the combustion process temperature sensor of combustion air damper shuts off air supply as there s the embers phase in the furnace Additionally the control unit can increase the chimney draught in the heating phase flap drive of the by pass of the heat accumulation module or by turning onthe draught generator In emergency situations power decrease as well the air damper opens enabling a full burn out of the fuel The special input for connecting any external control device
21. utton gt 2 stops blinking Parameters level 2 was chosen repeatedly CHOOSE button gt lt 30 gt Temp F3 shows up actual value CONFIRM button gt actual value to be changed begins blinking gt setting a new value CONFIRM gt confirming the new value repeatedly CHOOSE button till the parameter end setting screen appears once more CHOOSE gt Return to the operation screen of the control unit 4 Installing the control unit THECONTROLUNITIS SUPPLIED BY 230V 50HZ ANY MOVES REGARDING INSTALLATION SHOULD BE MADEATTHE DISCONNECTED MAINS THE CONTROL UNIT HAS TO BE CONNECTED TO THE MAINS WITHTHE ZERO PIN THE CONTROL UNIT SHOULD NOT BE EXPOSED TO WATER AFFECTING ITS ENVIRONS OUGHT TO BE CLEAN THE PRODUCER DOESN T TAKE ANY RESPONSIBILITY FOR DAMAGES CAUSED BY WRONG USAGE OF THE CONTROL UNIT Wiring according to fig 3 Combustion curve with marked control parameters air damper CHIMNEY Temp AF 1 F2 F3 F4 F5 F6 F7 F8 F9 Fstop HEAT 2 ACCUMULATION E lt 34 gt F6 7 MODULE PP air damper ee rep j STER YELLOW BLUE a 4 GND BLACK a D1 lt 35 gt F8max DOOR lt 23 gt Fstop SENSOR h lt 24 gt Fstop lt 37 gt F8 min ALARM WHITE GREEN X3 lt 22 gt F1 Alarm CO L MAINS eee pag EEEE PE 230V 50Hz 230V 50Hz
22. y of the article with the agreement Laws Journal No 141 Pos 1176 WARNING ANY MODIFICATION OF THE CONTROL UNIT MADE BY USER CAN BE THE CAUSE OF SAFETY CONDITIONS DETERIORATION AND CAN EXPOSE THE USER TO ELECTRIC SHOCK OR DAMAGE DEVICES SUPPLIED Connection cable of control unit may be replaced onl by producer or his authorized service locations WARNING 1 Producer does not take the responsibility for damage caused by atmospheric discharge 2 and overvoltage in the mains 3 Burnt fuses are not subject to warranty replacement Date of sale Seller s signature and stamp ARGO FILM Recycling Plant No 6 180 Krakowska st 52 015 Wroclaw Register No GIOS E 0002240WZ Worn out electronic the utilization collection place where will 0 515 122 142 be accepted for free WNASSX Zak ad elektroniczny TATAREK Jerzy Tatarek 50 559 Wroclaw 75 Swieradowska st ph 071 367 21 67 373 14 88 fax 373 14 58 tax index number 899 020 21 48 Bank account BZ WBK S A O WROCLAW 6910901522 0000 0000 5201 9335 www tatarek com pl E mail tatarek tatarek com pl and electric devices must be transfered to Ph 071 794 43 01 ps Demonstration change of the lt 30 gt Temp F3 parameter Parameters level 2 Press repeatedly button CHOOSE 7 till the Parameters level 0 parameter setting screen appears CONFIRM button gt 0 starts blinking twofold button gt 2 blinks CONFIRM b

Download Pdf Manuals

image

Related Search

Related Contents

コイスミ学習デスク  Maxon Telecom MM-6854 Modem User Manual  Conversor RT-2412 com Desligamento Imediato  Connect™ User Manual Blue Step Platform  LA TRANSMISSION  882 KB - Bureau de la sécurité des transports du Canada  Lowrance electronic Gen2 User's Manual  Mode d`emploi site Internet Charte qualité.pub    H25E201  