ML70S Programming

image

Contents

1. Passive 1 2 99 seconds Selection the time of cutting photocell signal and starting the nudging signal 09 DoorOpenInsp Time 180 seconds 10 180 seconds When the door stayed open selection the time of warning 10 CloseButton Delay 2 seconds Passive 1 2 20 seconds Delay time of close buton detection 11 Advanced DoorOpen 12 Dir OpenD Style Passive Passive Passive Active Passive Active If parameter value is passive when the direction arrows are on the same floor call is not imported If parameter value is active when the direction arrows are on and if the same floor call is come the automatic door is opened 13 Auto DoorWaitOpen Passive Passive Active Puk 000000 At full automatic door lifts selection of waiting the door opened This situation is not suitable to En amp 81 1 2 A3 standards To do this parameter active ML70S user must declear to our firm with writings and must accept the responsibility D Display Settings 01 FloorDisplay Sets Floor 00 Disp 0 Floor 00 23 Disp 0 19 1A 1b 1c 1d Display datas that will be screened on floors are changed 02 Dir Arrow Type Type 1 Type 1 Type 2 Type 3 Type 4 Selection of direction arrow types on MLKAT D card 03 Dir ArrowShiftSp Normal Normal Slow Very Slow No Shift Very Fast Fast Selection of direction arrow shift speed on MLKAT D card 04 ArticleShiftSpeed Norm
2. Single Sound Single sound on up and down direction Double Sound Double sound on up and down direction UpSingle DownDbIl Up direction single sound down direction double sound UpDbI DownSingle Up direction double sound down direction single sound Selection of gong type on floor cards 04 Gong Ringing Time When Car Stopped When Car Stopped Gong signal when the car stopped While Car Slowing Gong signal when the car is slowing for the next floor
3. 14 Binary M1 15 Binary M2 16 Binary M3 17 Binary M4 19 At Floor Signal 20 Up Arrow 21 Down Arrow 23 Overload 24 Out Of Service 25 Lirpomp 26 Middle Speed 2 3 Re levellingSpeed Re levelling speed output at electrical lifts 4 Ups Contactor UPS Inverter contactor at UPS rescue 6 Hyd Re lev Motor Lower power motor output at re levelling in hydraulic lifts 7 Middle Speed Output when the target floor is the nearest floor at electrical lifts 18 Nudging At full automatic door lifts output at the end of photocell blocking time 22 Fault Inverse At normal position there is always output at fault position output is cut off G Maintenance Sets 01 Next Maintenance 01 01 2013 Setting of next maintenance date 02 At Maint Date End Only Warn Only Warn Block The Lift 03 Reset Run Number No Yes No After the maintenance total run is reset 04 Delete Faults No Yes No H Evacuation Sets 01 Evacuation Type Evacuate WithKS10 Evacuate WithK S10 Evacuate With UPS Gearless WithVV VF At gearless machine systems rescue operation with VVVF motor control GearlessWithBrake At gearless machine systems rescue operation with openning brake only 02 Evacuation Delay 5 seconds 1 15 seconds After the detection of main power is cut selection of waiting time to start the rescue operation 03 EvacuationMaxTime 40 seconds 10 200 seconds Selection of maximu
4. MLKABIN B2 EIN1 Not Used Not Used 25 MLK ABIN B2 EIN2 Not Used Not Used 26 57 MLKATDO 31 A EIN Not Used Not Used 58 89 MLKATD0 31 B EIN Not Used Not Used Assignable Functions l MLKS10 EXO1 MLKS10 communication input 1 2 MLKS10 EXO2 MLKS10 communication input 2 3 Down Re levelling Down re levelling input 4 Up Re levelling Up re levelling input 5 Fire Fire input 6 Earthquake Earthquake input 7 Driver Fault Inverter fault input at UPS evacuation 8 Change Direction Change direction input at UPS evacuation 9 StarTriangleStart Star Triangle starting input 10 819 Limit Switch 11 820 Limit Switch 12 Overload Overload contact 13 Full Load Full load contact 14 Fireman Fireman key input 15 Panic Panic button input 16 Vatman Vatman key input 17 K16 Open Limit A A door open limit input 18 K19 Close Limit A A door close limit input 19 Open B B door open limit input 20 Close B B door close limit input 21 K16 Open Limit B B door open limit input 22 K19 Close Limit B A door close limit input 23 Photocell A A door photocell input 24 Photocell B B door photocell input 25 MO Pulse 26 M1 Pulse 27 JF Levelling Sw F Programm Outputs Programmable Outputs Sub Section Factory Settings Factory Settings for Electrical Lifts for Hydraulic Lifts 01 ML70S RY Re levellingSpeed Not Assigned Motor Valve Auxiliary Relay 02 ML70
5. PROGRAMMING Ver 1 0x e When the lift is stand by position by pressing ENTER button for 2 seconds programming mode starts Main Program Sub Program Name Sub Program Names Parameter No Registered Parameter Program Name Value When this arrow on screen When this arrow on screen can be entered to sub program parameter can be changed e You can choose sub program by using UP and DOWN buttons e To exit the programming mode ESC button in the main menu is used ENTER to ExitProgram is displayed on LCD screen Press ENTER button and exit the programming mode to return the main menu again press ESC button e When ENTER button in the main menu is pressed the sub program which has arrow on the screen starts And you can select the sub program with ENTER button again e Ifthe program has parameter an arrow appears at the beginning of the fourth line of LCD screen You can change the parameter value by using UP and DOWN buttons To store the value press the ENTER button and return the menu By pressing the ESC button the registered value is valid and you can return the sub menu PARAMETERS Program Factory Set Parameters Explanations A Language A Language Turkce Turkce English Pyccknit B System Settings 01 Lift Type Electrical Electrical Hydraulic Gearless 02 Command Type OneBt TwoWayColl OneBt OneWayColl There is one button on the floors in this command type If this button connected to whi
6. S RT Inspection Not Assigned It can be set Star Triangle Relay at KS10 rescue 03 ML70S RB Ups Contactor Not Assigned When ML65X EIN4 input is selected Star Triangle start relay that is dropped while there is this input 04 ML70S RLIR Lirpomp Lirpomp 05 ML70S OUTI1 Gong Gong 06 ML70S OUT2 Middle Speed 1 Hyd Re lev Motor 07 ML70S RA Not Used Not Used 08 ML70S RK Not Used Not Used 09 MLKABIN R EO1 Nudging Nudging 10 MLKABIN R RA Fixed Fixed 11 MLKABIN R RK Fixed Fixed 12 MLKABIN R RE1 Fixed Fixed 13 MLKABIN R RE2 Fixed Fixed 14 MLKABIN K A1I EO1 Gray Code MO Gray Code MO 15 MLKABIN K A1 EO2 Gray Code M1 Gray Code M1 16 MLKABIN K A1 EO3 Gray Code M2 Gray Code M2 17 MLKABIN K A1 EO4 Gray Code M3 Gray Code M3 20 MLKABIN K A 1 EO7 Down Arrow 18 MLKABIN K A 1 EO5 Overload Overload 19 MLKABIN K A1 E0O6 Inspection Inspection Down Arrow 21 MLKABIN K A 1 EO8 Up Arrow Up Arrow 22 29 MLKABIN K A2 EO1 8 Not Used Not Used 29 37 MLKABIN K B1 EO1 8 Not Used Not Used 38 45 MLKABIN K B2 EO1 8 Not Used Not Used 45 77 MLKAT D0 31 A EO Not Used Not Used 78 A9 MLKAT D0 31 B EO Not Used Not Used BO MLSERI65 GCx Gray Code Gray Code Assignable Functions l Inspection 2 Car Lamp 5 Gong 8 Gray Code M0 9 Gray Code M1 10 Gray Code M2 11 Gray Code M3 12 Gray Code M4 13 Binary MO
7. al Normal Slow Very Slow Very Fast Fast Selection of article shift speed on MLKAT D card 05 OUTofSERVICE Apx 06 Floor Display Set No Appendix Passive No Appendix FLOOR 1 FAULT 2 Selection of appendix that will added to OUT OF SERVICE article end on MLKAT D card Passive Active E PrgrammableInputs Programmable Inputs Sub Section Factory Settings Factory Settings for Electrical Lifts for Hydraulic Lifts 01 ML70S EIN1 MLKS10 EXO1 Not Used 02 ML70S EIN2 MLKS10 EXO2 Not Used 03 ML70S EIN3 Down Re levelling Not Used 04 ML70S EIN4 Up Re levelling Not Used 05 ML70S EINS5S Not Used 141 Fixed 06 ML70S EIN6 Fire Fire 07 ML70S EIN7 Earthquake Earthquake 08 ML70S EIN8 Not Used Not Used 09 ML70S EIN9 Not Used Not Used 10 ML70S EIN10 142 Floor Stopper 142 Fixed 11 ML70S EIN11 MO Pulse MO Pulse 12 ML70S EIN 12 M1 Pulse M1 Pulse 13 MLKABIN R EIN1 K16 Open Limit A K16 Open Limit A 14 MLKABIN R EIN2 K19 Close Limit A K19 Close Limit A 15 MLKABIN R EIN3 Down Re levelling Not Used 16 MLKABIN R EIN4 Up Re levelling Not Used 17 MLKABIN R EINS Full Load Full Load 18 MLKABIN A1 EIN1 Not Used Not Used 19 MLKABIN A1 EIN2 Not Used Not Used 20 MLKABIN A2 EIN1 Not Used Not Used 21 MLKABIN A2 EIN2 Not Used Not Used 22 MLKABIN B1 EIN1 Not Used Not Used 23 MLKABIN B2 EIN2 Not Used Not Used 24
8. car calls End of the floor wait time back to the normal working position Hold Calls When stop 120 signal is cut all car calls are registered and lift is stopped After the stop signal wait for any car call After the car call registered calls and the new call is collated and back to the normal working position 24 Top Less Floor Passive Passive 1 2 5 In doublex working up direction missing floor number of one of the lifts 25 Lower Less Floor Passive Passive 1 2 5 In doublex working down direction missing floor number of one of the lifts 26 Gray Binary Start 27 Car Call Cancel 28 Car Card Select 29 Floor Detection 30 0SG Brake Control 31 Elect Re levell 32 Evacuation Floor Passive KABIN R amp KABIN K Active Passive Passive Passive 0 1 5 At the up missing floor lifts selection of the starting number of gray code or binary output Passive Active If this parameter is selected active accepted call by pressing the button inside the car is canceled by pressing this button once again KABIN R amp KABIN K SERI65 amp INT65 Selection of car communication cards MO Pulse 2 Magnet MO Pulse 4 Magnet MO M1 Pulse Encoder Passive Active Cancel A3 Puk 000000 At geary machine systems over speed governor selenoid control card MLA3 must be used If it is used for the lifts that is not suitable to En amp 1 1 2 A3 standards to do this pa
9. ch direction floor calls are collective at that direction Car calls are collective in both directions OneBt TwoWayColl There is one button on the floors in this command type If this button connected to which direction floor calls are collective in both directions Car calls are collective in both directions SelectiveCollect Car calls are collective in both directions floor down calls are collective in down direction floor up calls are collective in up direction 03 Number Of Floor 16 2 32 04 Car Lamp Time 5 seconds 1 20 seconds The duration of car lamp ON 05 Lock Wait Time 15 seconds 5 25 seconds After CAM energized waiting time for lock signal 06 Maximum HighSpeed 15 seconds 10 100 seconds Max moving time at high speed between two floors 07 Maximum Low Speed 10 seconds 5 100 seconds Max moving time at low speed 08 Parking Time 30 seconds 10 100 seconds On stand by time of moving to park floor 09 Park Floor Passive Passive 0 1 31 On stand by park floor to go 10 Fire Floor Passive Passive 0 1 31 Target floor when detecting fire warning signal 11 Stop Delete Calls Passive Passive Active When pressed the stop button if the parameter value is passive car calls are kept in the memory and vice versa 12 Group ID Select Passive Passive A Panel B Panel C Panel D Panel 13 R S T Phase Ct
10. hts Floor 00 Omm Floor 00 15 99 0 99mm After the shaft learning tracing the floor heights that measured 11 CalculateDistance Passive Passive Active For explanation please look user manual 12 SlowingDistance3 50 cm 50 200 cm For explanation please look user manual 13 Correction Mode Passive Floor 00 15 99 0 99mm For explanation please look user manual J General Settings 01 Factory Sets No Yes No All parameter values are changed into factory settings 02 Clock Setting 00 00 Setting the clock 03 Date Setting 01 01 2013 Setting the date 04 Auto Tuning No Yes No If this parameter selected YES at UP and DOWN direction first movement in inspection mode OSG Brake Control input is not watched during 180 seconds 05 DeleteMLKR1Error No Yes No Stored faults info is deleted about MLKRI card 06 Delete UCM Error No Yes No Stored faults info as a result of UCM is deleted 07 UCM Up Test No Yes No 08 UCM Down Test No Yes No 09 ResetTotalRunNum No Yes No 10 Change Password 0000 Changing password 11 Cancel Password No Yes No Password is cancelled new value is 0000 12 SaveToDatakey No Yes No 13 Read Datakey No Yes No 99 Version 1 01 00 01 01 2013 K Gong Settings 01 Car Gong Passive Passive Active Selection of gong outputs on top of the car card passive or active 02 Floor Card Gongs Passive Passive Active Selection of gong outputs on floor card passive or active 03 Gong Type Single Sound
11. m movement time at rescue 04 Evacu JF MoveTime Passive Passive 0 1 10 0 seconds At rescue operation after the detection of JF selection of needed time to re levelling I Shaft Learning 01 Learn Shaft No Yes No If this parameter is chosen Yes shaft learning procedure is started 02 Hi SpeedSlowDist 120 cm 10 500 cm Starting distance selection of passing from the high speed to Slow speed to the exact floor 03 Mid Spd SlowDist 80 cm 10 500 cm Starting distance selection of passing from the high speed to slow speed when going to the nearest floor at high speed lifts 04 LowSpeedStopDist 05 Dist ToMidd Speed 70 mm 1 200 mm While approaching to the target floor selection of cutting distance of low speed signal 60 cm 1 500 cm To give the high speed signal selection of the nearest floor minimum distance 06 Reader Lenght 30 cm 07 817 Position Between 0 1 Floor Between 0 1 Floor Between 1 2 Floor Selection position of 817 lower limit switch 08 Up Level Correct Floor 01 00mm Floor 01 31 For All 99 0 99mm Selection of precision levelling adjustment for each floor on up direction 09 DownLevel Correct Floor 00 00mm Floor 00 30 For All 99 0 99mm Selection of precision levelling adjustment for each floor on down direction 10 Floor Heig
12. rameter passive ML70S user must declear to our firm with writings and must accept the responsibility Passive Active If needed re levelling this parameter is chosen active and MLKRI 1 door bridging card must be used Passive Active If panic input detected floor that the car will be parked C Door Settings 01 A DoorTypeSetting Floor 00 CarDoor For each floor A side door type can be set one by one and can be set at the same time 02 B DoorTypeSetting Floor 00 NoDoor For each floor B side door type can be set one by one and can be set at the same time 03 Door A Limit Type Without Limit With Limit Without Limit Limit type selection of A side door mechanism 04 Door B Limit Type Without Limit With Limit Without Limit Limit type selection of B side door mechanism 05 Door A Relay Set MLKABINR RA RK ML70S RA RK MLKABIN R RA RK MLKABIN R ER2 ER1 Selection of A side door open close signals that will be connected to which relays 06 Door B Relay Set MLKABIN R ER2 ER1 ML70S RA RK MLKABIN R RA RK MLKABIN R ER2 ER1 Selection of B side door open close signals that will be connected to which relays 07 Wait AtFloor Time 5 seconds 1 99 seconds At full automatic door systems stay opened time of automatic door at only indoor systems if the door doesn t open after the car stopped selection the time of the next call 08 PhotocellBlockT Passive
13. rl Without Sequence Passive Without Sequence Sequential 50Hz Sequential 60Hz 14 Motor PTC Control Active Passive Active 15 Phase AcceptLevel 50 0 100 It can be controlled phase level sensitivity when the parameter value is increased it can be accepted existing phases if their voltage levels are low 16 RX Delay Time 17 Inspect Move Type Passive To Limit Switch Passive 10 5000 ms In speed control systems when limit switch is on selection of stripping distance To Limit Switch In inspection mode car is moved to up and down limit switches To Exact Floor In inspection mode car is moved to up and down floor levels 18 Star TriangleTime 400 ms Passive 10 5000 ms Selection of star triangle relay RT convert time for hydraulic lifts 19 Motor Valve Time 400 ms Passive 10 5000 ms Motor run time after the valves closed for hydraulic lifts 20 Hyd Re levelling Passive Passive Active If this parameter selected active it is allowed re levelling for hydraulic lifts 21 Position Reset Passive Passive Active After the power off when the card is energized the car is moved to floor which has down limit bi stable switch 22 Maximum Car Calls 23 Stop Function Only Stop 1 24 Maximum car calls accepted in the cabin Only Stop When stop 120 signal is cut only lift is stopped no operation is done about the