Home
Opti Tri White Par - Elation Professional
Contents
1. Cable DMX Cable Requirements For DMX Operation The Opti Tri White Par can be controlled via DMX 512 protocol The Opti Tri White Par has 2 DMX Channel Modes 3 Channel mode and 6 Channel mode Your unit and your DMX controller require a approved DMX 512 110 Ohm Data cable for data input and data output We rec ommend Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all professional sound and lighting stores Your cables should be made with a male and female XLR connector on either end of the cable Also remember that DMX cable must be daisy chained and cannot be split Figure 1 Elation Professional www elationlighting com Opti Tri White Par Instruction Manual Page 5 Opti Tri White Par Set Up Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector Do not con nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior COMMON XLR Male Socket 1 E g Figure 3 Figure 2 XLR Pin Configuration Pin 1 Ground Pin 2 Data Compliment negative Pin 3 Data True positive Special Note Line Termination When longer runs of cable are used you may need to use a terminator on the last uni
2. extent prohibited by applicable law all implied warranties made by Elation Professionals in connec tion with this product including warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this prod uct after said period has expired The consumer s and or Dealer s sole remedy shall be such repair or replacement as is expressly provided above and under no circum stances shall Elation Professionalse be liable for any loss or damage direct or conse quential arising out of the use of or inability to use this product G This warranty is the only written warranty applicable to Elation Professionalse Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published Elation Professional www elationlighting com Opti Tri White Par Instruction Manual Page 13 Opti Tri White Par Notes Elation Professional www elationlighting com Opti Tri White Par Instruction Manual Page 14 Opti Tri White Par Specifications Model Opti Tri White Par SPECIFICATIONS Working Position Any safe working position Voltage 100V 240V 47 63Hz LED s 54 x 3 Watt Power Consumption 160W Max Fuse OA Beam Angle 20 Degrees Weight 10 5lbs 4 8Kgs Dimensions 11 L x 8 6 W x 14 H Colors Warm White Cool Wh
3. serviceable parts inside Never operate this unit when it s cover is removed Never plug this unit in to a dimmer pack Always be sure to mount this unit in an area that will allow proper ventilation Allow about 6 15cm between this device and a wall e Do not attempt to operate this unit if it becomes damaged This unit is intended for indoor use only use of this product out doors voids all warranties During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to the point they exit from the unit Cleaning The fixture should be cleaned only as recommended by the manufacturer See page 12 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances inclu ding amplifiers that produce heat e The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance C The appliance has been exposed to rain or water D The appliance does not appear to operate normally or exhibits a marked change in performance Elation Professional www elationlighting com Opti Tri White Par Instruction Manual Page 4 Opti Tri White Par
4. the display on again Be advised though that the display will turn off automatically after 10 seconds To set the display press the MODE button until DisoPerm XX is dis played XX represents either ON or OFF DispPerm ON LCD display light is on at all times DispPerm Off LCD display light shuts off after 10 seconds Operating Modes e Sound Active mode In this mode the unit will react to sound e Macro Mode Preset Color Temperatures There are 13 macros preset color temperatures macros to choose from e DMX control mode This function will allow you to control each individual fixtures traits with a standard DMX 512 controller such as as the Elation Show Designer Master Slave Operation This function will allows you to link units together to run in a Master Slave mode In Master Slave operation one unit will act as the con trolling unit and the others will react to the controlling units built in programs Any unit can act as a Master or as a Slave however only one unit can be programmed to act as the Master Master Slave Connections and Settings 1 Daisy chain your units via the XLR connector on the rear of the unit Use standard XLR data cables to link your units together Remember that the Male XLR connector is the input and the Female XLR connector is the ouput The first unit in the chain master will use the female XLR connector only The last unit in the chain will use the male XLR connector on
5. MASTER DIMMER 0 100 AN AAN a mT mse ees eee Elation Professional www elationlighting com Opti Tri White Par Instruction Manual Page 11 Opti Tri White Par Fuse Replacement Disconnect from the main power supply Insert a standard flat head screw driver in to the fuse holder housing located on the back of the unit Turn the screwdriver in counter clockwise direction to remove the fuse holder Remove the old fuse and discard it replace the fuse with the same type Insert the fuse back into it s housing Opti Tri White Par Cleaning Due to fog residue smoke and dust cleaning the internal and exter nal optical lenses must be carried out periodically to optimize light output 1 Use normal glass cleaner and a soft cloth to wipe down the outside casing Clean the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in which the fixture operates i e smoke fog residue dust dew pa Opti Tri White Par Trouble Shooting Listed below are a few common problems the user may encounter with solutions Unit not responding to DMX 1 Check that the DMX cables are connected properly and are wired correctly pin 3 is hot on some other DMX devices pin 2 may be hot Also check that all cables are connected to the right connectors it does matter which way the inputs a
6. MODE Color CW Temperature k 600 0 2 a 1 0 0 2 o gt 20 0 2 2 6 8 AMBER OI Ol1f OI o 0 80 130 255 130 z gt o s600 227 255 255 Opti Tri White Par UI OIJ OI Ol OI OI OI O1f O1f O1f O OI f OI D Macro Preset Temperatures CW 495 FC 5333 LUX 132 FC 1407 LUX 58 FC 622 LUX 35 FC 379 LUX 24 FC 255 LUX WW 353 FC 3797 LUX 85 FC 913 LUX 39 FC 416 LUX 23 FC 248 LUX 15FC 166 LUX A 185 FC 1991 LUX 50 FC 543 LUX 23 FC 246 LUX 14 FC 147 LUX 9 FC 99 LUX ALL 949 FC 10210 LUX 259 FC 2789 LUX 117 FC 1263 LUX 69 FC 742 LUX 74 FC 798 LUX 20 Beam Angle O ft 3 2 ft 6 6 ft 9 8 ft 13 1 ft 16 4 ft Elation Professional www elationlighting com Opti Tri White Par Instruction Manual Page 10 Opti Tri White Par 3 Channel Mode Bid Mi A 0 255 COOL WHITE 0 100 0 255 WARM WHITE 0 100 0 255 Opti Tri White Par Channel AMBER 0 100 6 Channel Mode Function COOL WHITE 0 100 WARM WHITE 0 100 0 255 AMBER 0 100 MACROS COLOR TEMPERATURES 0 18 OFF 19 37 MACRO 1 6000k 38 56 MACRO 2 5700k 57 75 MACRO 3 5400k 76 94 MACRO 4 5100k 95 113 MACRO 5 4800k 114 492 MACRO 6 4500k 133 151 MACRO 7 4200k 152 170 MACRO 8 3900k 171 189 MACRO 9 3600k 190 208 MACRO 10 3300k 209 227 MACRO 11 3000k 228 246 MACRO 12 2700k 247 255 MACRO 13 2400k 0 255 STROBING SLOW FAST 6 0 255
7. Opti Tri White Par Introduction Unpacking Thank you for purchasing the Opti Tri White Par by Ela tion Professionale Every Opti Tri White Par has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during ship ping If the carton appears to be damaged carefully inspect your fix ture for any damage and be sure all accessories necessary to operate the unit has arrived intact In the case damage has been found or parts are missing please contact our customer support number for further instructions Do not return this unit to your dealer without first contact ing customer support Introduction The Opti Tri White Par is part of Elation Profession als continuing pursuit for creating high quality affordable intelligent fixtures The Opti Tri White Par is a powerful DMX intelligent LED wash This wash is light weight and compact which makes it a great piece for mobile DJ s and clubs This unit can be used as a stand alone unit or in a master slave configuration The unit can run in sound active mode Auto mode or be controlled via DMX controller Customer Support oElation provides a customer support line to provide set up help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www elationlighting com for any comments or sugges tions Service Hours are Monday t
8. Set Up Power Supply The Elation Opti Tri White Par contains an automatic voltage switch which will auto sense the voltage when it is plugged into the power source With this switch there is no need to worry about the correct power voltage this unit can be plugged in anywhere DMX 512 DMX is short for Digital Multiplex This is a universal pro tocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions from the controller to the fixture DMX data is sent as serial data that trav els from fixture to fixture via the DATA IN and DATA OUT XLR ter minals located on all DMX fixtures most controllers only have a DATA QUT terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compli ant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data
9. ar carries a two year limited warranty Please fill out the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the problem as well as the R A number must also be written down on a piece of paper included in the shipping carton If the unit is under warranty you must provide a copy of your proof of purchase invoice You may obtain a R A number by contacting our customer support team on our customer support number All pack ages returned to the service department not displaying a R A number on the outside of the package will be returned to the shipper Elation Professional www elationlighting com Opti Tri White Par Instruction Manual Page 3 Opti Tri White Par Safety Precautions e To reduce the risk of electrical shock or fire do not expose this unit rain or moisture Do not spill water or other liquids into or on to your unit Do not attempt to operate this unit if the power cord has been frayed or broken Do not attempt to remove or break off the ground prong from the electrical cord This prong is used to reduce the risk of electrical shock and fire in case of an internal short Disconnect from main power before making any type of connection Do not remove the cover under any conditions There are no user
10. ents the fade speed 3 Use the UP or DOWN buttons to adjust the fade speed 1 is the slowest speed 16 the fastest speed Note If the Warm White Cold White and Amber dimmer modes are all set to 0 there will be no light output in this mode DMX Mode Operating through a DMX controller gives the user the freedom to create their own programs tailored to their own individual needs The Opti Tri White Par has two DMX Channel Modes 3 Channel mode amp 6 Channel mode 1 This function will allow you to control each individual fixture s traits with a standard DMX 512 controller 2 Torun your fixture in DMX mode you must first select which DMX Channel mode you want to use 3 To select 3 Channel mode press the MODE button until DMX 3CH DMX X is displayed X represents the current displayed address Select your desired DMX address using the UP or DOWN buttons 4 To select 6 Channel mode press the MODE button until DMX 6CH DMX X is displayed X represents the current dis played address Select your desired DMX address using the UP or DOWN buttons 5 Once you have chose your desired DMX channel mode and set the DMX address plug in the fixture via the XLR connections to any standard DMX controller 6 Please see page 11 for DMX values and traits Elation Professional www elationlighting com Opti Tri White Par Instruction Manual Page 9 Opti Tri White Par Macro Preset Temperatures
11. hrough Friday 9 00 a m to 5 00 p m Pacific Standard Time Voice 323 582 3322 Fax 323 582 3108 E mail support elationlighting com Warning To prevent or reduce the risk of electrical shock or fire do not expose this unit to rain or moisture Caution There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufactures war ranty In the unlikely event your unit may require service please contact User Instructions Elation customer support PLEASE recycle the shipping carton when ever possible Intertek 2003021 8 11 Elation Professional www elationlighting com Opti Tri White Par Instruction Manual Page 2 Opti Tri White Par General Instructions To optimize the performance of this product please read these operating instructions carefully to familiarize yourself with the basic operations of this unit These instructions contain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference Opti Tri White Par Features Dual Yoke for Floor Mounting DMX 512 protocol 2 DMX Channel Modes 3 Channel mode amp 6 Channel Mode Dimming 0 100 3 and 5 Pin DMX Inputs and Outputs Tri White Technology Cool Warm amp Amber Built In Microphone for Sound Active Mode 13 Preset Color Temperatures Macros Strobing Opti Tri White Par Warranty Registration The Opti Tri White P
12. ite amp Amber DMX Channels 2 DMX Modes 3 Channel Mode amp 6 Channel Mode Warranty 2 Year 730 days Auto Sensing Voltage This fixture contains a automatic voltage switch which will auto sense the voltage when it is plugged into the power source Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Elation Professionals A Division of the AmericanDJ Group of Companies World Headquarters 6122 S Eastern Ave Los Angeles CA 90040 USA Tel 823 582 3322 Fax 323 582 3311 Web www elationlighting com E mail info elationlighting com American DJ Europe Junostraat 2 6468 EW Kerkrade Netherlands service adjgroup eu www americandj eu Tel 31 45 546 85 00 Fax 31 45 546 85 99 Elation Professional www elationlighting com Opti Tri White Par Instruction Manual Page 15
13. ly 2 Set the Master unit to your desired mode of operation For the Slave unit s set the display to DMX address 1 Connect the Slave unit or units and they will automatically start to follow the Master aa Elation Professional www elationlighting com Opti Tri White Par Instruction Manual Page 7 Opti Tri White Par Operating Instructions Sound Active Mode In this mode the Opti Tri White Par will react to sound 1 Plug the fixture in and press the MODE button until SoundCtl Color is displayed The unit will now react to the beat of the music Dimmer Mode 1 Plug the fixture in and press the MODE button until 2 When ColorSet Cool X is displayed you are in Cool White dim ming mode Press the UP and DOWN buttons to adjust intensity 3 When ColorSet Warm X is displayed you are in Warm White dimming mode Press the UP and DOWN buttons to adjust inten sity 4 When ColorSet Amber X is displayed you are in Amber dimming mode Press the UP and DOWN buttons to adjust intensity 5 To return to previous dimming modes you must press the MODE button until that mode is displayed again Continue to make adjustments until your desired color output temperature is reached 6 You can use the chart on page 10 to adjust the dimmer s to cer tain color temperatures Macro Mode Preset Color Temperature In this mode you are able to choose one of 13 macros preset color tempe
14. nd outputs are connected Unit does not respond to sound 1 Quiet or high pitched sounds will not activate the unit Elation Professional www elationlighting com Opti Tri White Par Instruction Manual Page 12 Opti Tri White Par 2 YEAR LIMITED WARRANTY Warranty A Elation Professionals hereby warrants to the original purchaser Elation Profes sionals products to be free of manufacturing defects in material and workmanship for a period of two years 730 days from the date of purchase This warranty shall be valid only if the product is purchased within the United States of America including possessions and territories It is the owner s responsibility to establish the date and place of purchase by acceptable evidence at the time service is sought B For warranty service send the product only to the Elation Professionals factory All shipping charges must be pre paid If the requested repairs or service including parts replacement are within the terms of this warranty Elation Professionalse will pay return shipping charges only to a designated point within the United States If the entire instrument is sent it must be shipped in its original package No accessories should be shipped with the product If any accessories are shipped with the product Elation Professionalse shall have no liability whatsoever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial
15. number has been altered or removed if the prod uct is modified in any manner which Elation Professionals concludes after inspec tion affects the reliability of the product if the product has been repaired or serviced by anyone other than the Elation Professionalse factory unless prior written authori zation was issued to purchaser by Elation Professionalse if the product is damaged because not properly maintained as set forth in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specified above Elation Profession als will replace defective parts at its expense and will absorb all expenses for war ranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professionals under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of Elation Professionalse All products covered by this warranty were manufactured after January 1 1990 and bear identifying marks to that effect E Elation Professionals reserves the right to make changes in design and or improvements upon its products without any obligation to include these changes in any products theretofore manufactured F No warranty whether expressed or implied is given or made with respect to any accessory supplied with products described above Except to the
16. ratures 1 Plug the fixture in and press the MODE button until MacroSet Mode X is displayed X represents the current macro number that is displayed Each macro is a preset color temperature that is set at the factory There are 13 color temperatures to choose from 2 Use the UP and DOWN buttons to find your desired preset macro See the chart on page 10 for the list of macros and the color tem perature it represents Strobe Mode In this mode you can activate the strobe The strobe mode will only work in conjunctions with the Dimmer mode 1 First adjust the Cool White Warm White and Amber so that your desired output color is reached 2 Press the MODE button until ColStrob Speed XX is displayed Elation Professional www elationlighting com Opti Tri White Par Instruction Manual Page 8 Opti Tri White Par Operating Instructions XX reprents the strobe speed 3 Use the UP or DOWN buttons to adjust the strobe speed 1 is the slowest speed 20 the fastest speed Note If the Warm White Cold White and Amber dimmer modes are all set to 0 there will be no light output in this mode Fade Mode In this mode you can activate the auto fade The fade mode will only work in conjunctions with the Dimmer mode 1 First adjust the Cool White Warm White and Amber so that your desired output color is reached 2 Press the MODE button until ColProgr Speed XX is displayed XX repr
17. t to avoid erratic behavior A terminator is a 110 120 ohm 1 4 watt resistor which is con nected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line Using a cable terminator ADJ part number Z DMX T will decrease the possibilities of erratic behavior Termination reduces signal errors and avoids signal transmission problems 2 and interference It is always advisable G X z to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture Figure 4 5 Pin XLR DMX Connectors Some manufactures use 5 pin DMX 512 data cables for DATA transmission in place of 3 pin 5 pin DMX fixtures may be implemented in a 3 pin DMX line When inserting stan dard 5 pin data cables in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a proper cable conversion 3 Pin XLR to 5 Pin XLR Conversion 3 Pin XLR Female Out 5 Pin XLR Male In Sata Compliment signal ST Elation Professional www elationlighting com Opti Tri White Par Instruction Manual Page 6 Opti Tri White Par Operating Instructions LED Display On Off To set the display light to turn off after 10 seconds press the MODE button until DispPerm is displayed Using the Now the display will blackout after 10s Press any button to turn