Home
Model IGW 6000
Contents
1. ly LisTeD 3172293 FCC ID W4V IGW6000 IC 8173A IGW6000 C This product has been tested to the requirements of CAN CSA C22 2 No 61010 1 second edition including amendment 1 or a later version of the same standard incorporating the same level of testing requirements Note If used in a manner not specified by the manufacture the protection provided by the equipment may be impaired Note If used in a manner not specified by the manufacture the protection provided by the equipment may be impaired Distributed by ENERGY FOCUS INC 32000 Aurora Road Solon OH 44139 1 800 327 7877 Manufactured by WaterLevV Inc Montreal Canada Rev 4 05222009 www energyfocusinc com WaterLevV Installation Manual Model IGW 6000 Wireless Version Pool and Spa Water Level Monitoring System Thank you for purchasing the Industries newest and most technologically advanced Pool Spa water level monitoring devices on the market Your new Pool Spa Water Level System is fully automatic The system incorporates several user alarms which indicate both Water Level or flow issues and System monitoring such as Low Battery monitoring and loss of water flow Please Read before Installation Systems Contents Sensor Unit 9 volt Battery pre installed Sensor Mounting Bracket Skimmer Lid Bracket Valve Control Unit with built in Check Valve 2 x 2 x PVC T Fitting 4 Garden Hose Adapter User
2. is possible Disconnect Drain and or shut off the water source System Functions Sensor is in a Start up test mode for the first 10 minutes after Sensor is installed in the Sensor Bracket this will allow you to test the level by moving the Sensor unit up or down on the bracket to test Valve activation If further testing is required simply remove sensor and re insert back into the bracket this will restart the test mode See Sensor LED definitions below Low Water Level monitoring The WaterLevV System will automatically verify the Pool or Spa s water level every hour The system will automatically add water in 5 minute intervals whenever a low level is detected High Water Level monitoring If an extended High Water Level more than 12 hours is detected the system will alert you a Back Wash or drain may be required to lower the water level If the High Level is minor standard water dissipation over the following days will automatically reset High Level Alarm and the system will returns to normal status Low Battery Level detection The system automatically verifies the remaining Battery Power and will alert you when a Battery needs replacing see Battery replacement procedure Water Flow monitoring The system automatically monitors Water flow If an extended loss of water flow is detected a Flow Alarm will be triggered This alarm also can detect a leak in the Pool an excessive number of low Level de
3. s Manual and Installation Manual Remove contents from shipping packaging and verify contents are complete Before starting the installation verify that the pool is filled to the desired level Please see Figure A for typical system configuration x Valve Unit Ts Pump ly censor Skimmer dot S T Return to Pool GT Figure A Unit Specifications sensor Unit Power operation Operating Cycle Operating Range Model IGW 6000 Range Operating Frequency Installation Seasonal operation Storage Temperature Warranty Valve control Unit Power Supply Rain tight outdoor type Operating Cycle Operating Temperature Model IGW 6000 Range Operating Frequency Inlet Fitting Type Outlet Fitting Type Water pressure System Alarms Warranty 9 Volt Alkaline Battery Level Check every 1 hour 40 F to 125 F 5 C to 55 C 100 ft 30 meters 433 MHz Adjustable height Removable 20 F to 150 F 5 C to 65 C 1 Year 120VAC 138mA 9VDC 1A rating 5 minute Valve on Time 40 F to 125 F 5 C to 55 C 100 ft 30 meters 433 MHz 3 4 Male Garden Hose Fitting Male 3 4 NPT 15 100 PSI Low Battery High Water No Flow Possible Leak 1 Year Maintenance If the system no longer maintains the water level please check the following 1 Water Inlet screen may be blocked with dirt or debris Solution Shut off the water source
4. and remove Inlet connection and then remove the 3 3 adapter The Dirt screen is located in the Inlet port remove clean and replace Reconnect the water connection and turn on the water source 2 Lose of Power Solution e Verify that the Battery in Sensor is good 8 5 9 volt e Verify that the Power Adapter is plugged and functioning e Power LED of the Valve Unit should be On Notes Choose a location to install Sensor Bracket some possible locations are in the neck of the skimmer behind the skimmer weir or on any surface touching the water Keep in mind to keep the Sensor away from being hit or damaged from Childs play or other objects Install the Sensor in the Bracket and adjust Sensor approximately 1 4 above Water level A Skimmer Lid Bracket is also supplied in the case that the Sensor is to be placed attached to the Skimmer Lid Place Sensor Here Figure B Skimmer Lid Bracket Figure C Skimmer Bracket can be installed with ABS compatible adhesives such as ABS Pipe Cement or Attach with Screws Shut off the power to the Pool Pump and switch the Filter control to Drain or Back Wash Locate the return line from the Pool pump to the Pool Choose a location on the return line to cut and install T fitting See Figure D From Pump v Return to Pool Figure D Glue T fitting with the 3 Fitting pointing vertically upwards Let glue set f
5. mands may indicate a leak Sensor LED definitions as follows YELLOW indicates LOW LEVEL Detection RED indicates HIGH LEVEL Detection GREEN indicates Send Data Power Source Connection Remove the Blue Valve Cover then remove the Cable Clip by loosening the Phillips screw located on the outside of the Valve Unit Remove the Clip and install the Power Supply Cable Insert Power Connector with Cable pointing upwards and then loop the cable downwards See Figure F Replace Cable Clip and tighten Philips Screw to lock the Power Cable in place svoc i Water Inlet De Figure F Water Source Connection Install Garden Hose adapter to Valve Unit Inlet Attach the short side of the Fitting to the Valve and the longer side is to attach to your Water Source This connection is necessary to leave access the Water inlet Screen Filter for future cleaning See Figure G amp H If a permanent Water source is preferred use standard 4 GHT fitting to complete Inlet connection Figure G Figure H Apply Water source to verify there are no leeks Return Filter Control to normal position and turn on the Pool Pump Installation is now complete System Start up sensor Unit has a built in Start up mode which gives the Installer time 10 min to adjust the Sensor Level and visually see LED s display the Water Level Status If additional testing time is required simply re
6. move and replace the Sensor back in its Bracket this will restart the start up period
7. or one to two minutes See Figure E Return to Pool Figure E Next apply 2 3 turns of plumber tape to the outlet of the Valve unit Thread Valve Unit into the 3 T fitting Tighten Valve by hand do not use Pliers or grips Control Unit LED definition as follows LED No 1 Indicates Power On Status LED No 2 Indicates Data Received LED No 3 Indicates Valve activation LED No 4 Indicates Low Battery Alarm 2 Beeps every 5 minutes LED No 5 Indicates High Level Alarm 4 Beeps every 6 minutes LED No 6 Indicates Water Flow Error Warble Tone every 7 minutes Control Valve Reset Switch definition Press Reset Button for 1 second to silence Alarms Press and Hold Reset Button for 3 seconds to Reset Alarms Battery replacement procedure Remove the battery cover located on the back of the sensor by removing the 4 Phillips screws Replace the Battery with a 9V Alkaline Battery Replace Battery cover and insure gasket is seated correctly make sure to install all 4 screws In the case of the loss of a screw spare screws are supplied in the Battery compartment System Seasonal Power down procedure Remove the Sensor from the Bracket and store in a cool dry place until next season While Sensor is removed from Bracket the Sensor is powered off to conserve Battery life Disconnect the Valve Units power source or Power Supply cable If you live in an area where Freezing
Download Pdf Manuals
Related Search
Related Contents
IRON - Aslotel Samsung SMART CAMERA ST200F User Manual ÖWAMAT Betriebshandbuch [PDF 610 KB] Mode d'emploi a お手入れについて HPI Racing 105406 SmartMetals 063.0460 flat panel wall mount JVC Everio GZ-HM200 Dual SD High-Def HD Camcorder Red BigVALUEInc Accessory Saver 8GB Filters/Lenses Battery/Charger Bundle Copyright © All rights reserved.
Failed to retrieve file