Home

QnA Series Ethernet Interface Module User`s Manual

image

Contents

1. Transceiver 5 When using A1SJ71QE71N B5 when the FG signal is regulated on the side of the external power supply of the original power supply for the transceiver ground the FG signal at the original power supply 5 1 Connecting to the 10BASE T AJ71QE71N3 T A1SJ71QE71N3 T Connection procedure 1 Connect the twisted pair cable and the hub 2 Connect the twisted pair cable to the QE71 For AJ71QE71N3 T 5 2 Connecting to the 10BASE5 AJ71QE71N B5 A1SJ71QE71N B5 Supply power Connection procedure ki for transceiver 1 Slide the retainer toward the direction A as shown in the figure AUI Cable 2 Push in the AUI cable connector all the Way 3 Slide the retainer toward the direction B as shown in the figure 4 Confirm that the AUI cable is locked 5 Supply power to the transceiver 7 2 Refer to 2 in Chapter 2 For AJ71QE71N B5 B Retainer 1 Connect the AUI cable while the power to the module mounting station is turned off 2 Use a transceiver with a function that is generally called SQETEST or heart beat a transceiver function that emits signals to notify whether the transceiver is operating normally at the end of communication 5 3 Connecting to the 10BASE2 AJ71QE71N B2 A1SJ71QE71N B2 Connection procedure 7 2 1 Push in the connector by aligning the groove 1 and tab 2 as shown in the figure 2 While pushing
2. utca 14 Box 426 Fax 1 847 478 22 53 HU 1107 Budapest SE 20124 Malm Phone 36 0 1 431 9726 Phone 46 0 40 35 86 00 Fax 36 0 1 431 9727 Fax 46 0 40 93 23 01 Beijer Electronics SIA LATVIA Omni Ray AG SWITZERLAND Ritausmas iela 23 Im Sch rli 5 1V 1058 Riga CH 8600 D bendorf Phone 371 0 784 2280 Phone 41 0 44 802 28 80 Fax 371 0 784 2281 Fax 41 0 44 802 28 28 Beijer Electronics UAB LITHUANIA GTS TURKEY MITSUBISHI ELECTRIC Savanoriu Pr 187 LT 02300 Vilnius Phone 370 0 5 232 3101 Fax 370 0 5 232 2980 Bayraktar Bulvari Nutuk Sok No 5 TR 34775 Yukari Dudullu Umraniye ISTANBUL Phone 90 0 216 526 39 90 Fax 90 0 216 526 3995 CSC Automation Ltd UKRAINE 4 B M Raskovoyi St UA 02660 Kiev Phone 380 0 44 494 33 55 Fax 380 0 44 494 33 66 Mitsubishi Electric Europe B V FA European Business Group Gothaer Strafie 8 D 40880 Ratingen Germany FACTORY AUTOMATION Tel 49 0 2102 4860 Fax 49 0 2102 4861120 infogmitsubishi automation com www mitsubishi automation com
3. 89 99 Paola Hill Ul Zhambyla 28 Gothaer Stra e 8 AT 2500 Baden Malta Paola PLA 1702 KAZ 100017 Karaganda D 40880 Ratingen Phone 43 0 2252 85 55 20 Phone 356 0 21 697 816 Phone 7 7212 50 10 00 Phone 49 0 2102 486 0 Fax 43 0 2252 488 60 Fax 356 0 21 697 817 Fax 4 7 7212 50 1150 Fax 49 0 2102 486 1120 TEHNIKON BELARUS INTEHSIS stl MOLDOVA MITSUBISHI ELECTRIC EUROPE B V orgsl CZECH REP Oktyabrskaya 16 5 Off 703 711 bld Traian 23 1 Czech Branch BY 220030 Minsk MD 2060 Kishinev Avenir Business Park Radlick 714 113a Phone 375 0 17 210 46 26 Phone 373 0 22 66 4242 MIDDLE EAST REPRESENTATIVES CZ 158 00 Praha 5 Fax 375 0 17 210 46 26 Fax 373 0 22 66 4280 TT dee ESCO DRIVES amp AUTOMATION BELGIUM HIFLEX AUTOM TECHNIEKB V NETHERLANDS 94 shenkar St Kiryat Arie e Culliganlaan 3 Wolweverstraat 22 11 49001 Petah Tiqva MITSUBISHI ELECTRIC EUROPE B V FRANCE BE 1831 Diegem NL 2984 CD Ridderkerk Phone 972 0 3 922 1824 French Branch Phone 32 0 2 717 64 30 Phone 31 0 180 46 6004 Fax 972 0 3 924 0761 25 Boulevard des Bouvets Fax 32 0 2 717 6431 Fax 31 0 180 44 23 55 EECH PUE vi eae E Koning amp Hartman bw BELGIUM Koning amp Hartman b v NETHERLANDS 9113 ymanut P 0 B 6272 F erg ja o Woluwelaan 31 Haarlerbergweg 21 23 1L 42160 Netanya ax 33 0 BE 1800 Vilvoorde NL 1101 CH Amsterdam Phone 972 0 9 863 39 80 MITSUBISHI ELECTRIC EUROPE B V IR
4. 0 Carretera de Rubi 76 80 Tel 66 2 682 6522 08190 Sant Cugat del Valles Indonesia P T Autoteknindo SUMBER MAKMUR Barcelona Spain JI Muara Karang Selatan Block a Utara Tel 34 93 565 3131 No 1 Kav No 11 Kawasan Industri France Mitsubishi Electric Europe B V French Pergudangan Jakarta Utara 14440 Branch Tel 62 21 663 0833 25 Boulevard des Bouvets F 92741 India dee Systems Put Ltd e ectronic Sadan NO 111 Unit No15 Nanterre Cedex France M I D C BHOSARI PUNE 411026 India TEL 33 1 5568 5568 Tel 91 20 712 2807 South Africa Circuit Breaker Industries LTD Australia Mitsubishi Electric Australia Pty Ltd Tripswitch Drive Elandsfontein Gauteng 348 Victoria Road PostalBag No 2 South Africa Rydalmere N S W 2116 Australia Tel 27 11 928 2000 Tel 61 2 9684 7777 SM MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE 1 8 12 OFFICE TOWER Z 14F HARUMI CHUO KU 104 6212 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN Specifications subject to change without notice Printed in Japan on recycled paper A MITSUBISHI ELECTRIC HEADQUARTERS EUROPEAN REPRESENTATIVES EUROPEAN REPRESENTATIVES EURASIAN REPRESENTATIVES MITSUBISHI ELECTRIC EUROPE B V EUROPE GEVA AUSTRIA ALFATRADE Ltd MALTA TOO Kazpromavtomatika KAZAKHSTAN German Branch Wiener Stra e
5. 0 73Ib 0 35kg 0 771b A1SJ71QE71N B5 A1SJ71QE71N B2 0 19kg 0 20kg 1 Length between hub and node 2 It is required to use the one that satisfies the specifications of the transceiver and the AUI cable Also for the AJ71QE71N B5 the voltage drop Max 0 8V must be taken into account 1 Each item in the transmission specifications gives supplementary explanation When connected by 10BASE2 10BASE5 Segment length Terminator Segment length Maximum distance between nodes Segment length 20000000 Maximum 100 m Cascade connection J 328 08 ft is a maximum of 4 stages 90000000 ZZ C2000000 Maximum 100 m 328 08 ft QE71 2 Hardware specifications for QE71 are based on IEEE802 3 3 Settings and Names of Each Part AJ71QE71N3 T AJ71QE71N B5 AJ71QE71N B2 AJ71QE71N3 TS AJ71QE71N B5 AJ71QE71N B2E RUN BUF1 RUN BUF1 RUN BUF1 BUF2 BUF2 BUF2 RDY BUFS RDY BUF3 RDY BUF3 BSY BUFA BSY BUF4 BSY BUF4 SW ERR BUF5 SW ERR BUFS SW ERR BUES COM ERR BUF amp COM ERR BUF6 COM ERR BUES B 1 TEST TEST TEST ERR TEST ERR TEST TEST ERR HHBBBHHB 10BASE T Q d 10BASES 1 O 9 Side view indicated A1SJ71QE71N3 T A1SJ71QE71N B
6. 5 A1SJ71QE71N B2 by arrow A A1SJ71QE71N3 T A1SJ71QE71N B5 A1SJ71QE71N B2 RUN BUF1 RUN BUF1 RUN BUF1 RDY BUF2 RDY BUF2 RDY BUF2 BSY BUF3 BSY BUF3 BSY BUFS mE ES 41 GER lt Mee BH 4 1 COM ERR BUFS LERR LERR TEST BUF6 TEST BUF6 TEST BUF6 TEST ERR BUF7 TEST ERR BUF7 TEST ERR BUF7 SS CPU RW BUF8 CPU R W BUF8 CPU R W BUF8 ES Ess E MODE O ONLINE O ONLINE SEH TT 2 1 OFFLINE 2 TESTI Set 2 TEST1 3 TEST2 Y 3 TEST2 ATEST3 ATEST3 S TEST4 5 TEST4 l 9 91 10BASE5 10BASE T 4 8 p3 5 oS 6 A1SJ71QE71N3 T A1SJ71QE71N B5 A1SJ71QE71N B2 Display LED Refer to 1 2 Operation mode setting Refer to 2 switch 3 Exchange condition setting Refer to 3 switch 10BASE T connector RJ45 SES for connecting the QE71 to the 10BASE Lamp for verifying if power is being supplied to the External power supply transceiver indicator lamp ON Power supplying OFF Power not supplied Power source terminals for power source supply to External power supply the transceiver terminal AJ71QE71N B5 14 08V to 15 75V A1SJ71QE71N B5 13 28V to 15 75V Connector for connecting the QE71 to the 10BASES AUI cable connector For connection of 10BASE5 use AUI cable KEE cable 8 10BASE2 connec
7. A 1 DESIGN PRECAUTIONS NCAUTION When laying the control wire or communication cable do not bundle with or place near main circuit or power line Keep them at least 100 mm 3 94 in away from such cables Noise may cause erroneous operation INSTALLATION PRECAUTIONS NCAUTION Use the PLC in the environment given in the general specifications section of the user s manual to be used Using the PLC outside the range of the general specifications may result in electric shock fire or erroneous operation or may damage or degrade the product e Insert the fixing latch on the bottom of the module into the fixing hole in the base unit and install the module using the hole point as a fulcrum The Q2AS series module shall be fastened by screws in the base unit at the specified torque Not installing the module correctly could result in erroneous operation damage or pieces of the product falling e Tighten the screw within the range of specified torque If the screws are loose it may result in fallout short circuits or malfunction Tightening the screws to far may cause damage to the screw and or the module resulting in fallout short circuits or malfunction e Shut off all phases of the external power supply in the system before mounting or dismounting the module If you do not switch off the external power supply it will cause electric shock or damage to the product Do not touch the electronic parts or the modul
8. A MITSUBISHI ELECTRIC MELSEC A Series Programmable Logic Controller User s Manual Hardware A 1S J71QE71N3 T A 1S J71QE71N B5 A 1S J71QE71N B2 Ethernet Interface Module PAPAE MITSUBISHI ELECTRIC INDUSTRIAL AUTOMATION Version A e SAFETY PRECAUTIONS e Always read before starting use When using Mitsubishi equipment thoroughly read this manual and the associated manuals introduced in the manual Also pay careful attention to safety and handle the module properly These precautions apply only to the installation of Mitsubishi equipment and the wiring with the external device Refer to the user s manual of the CPU module to be used for a description of the PLC system safety precautions These e SAFETY PRECAUTIONS e classify the safety precautions into two categories DANGER and CAUTION Ue AUTISM M I afta eT IAE er AE EET TN lt SDANGER Procedures which may lead to a dangerous condition and cause death or serious injury if not carried out properly Procedures which may lead to a dangerous condition and A CAUTION cause superficial to medium injury or physical damage only if not carried out properly Depending on circumstances procedures indicated by NCAUTION may also be linked to serious results In any case it is important to follow the directions for usage Store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user
9. Corporate Woods Parkway Vernon 10th Floor Manulife Tower 169 Electric Hills IL 60061 Road North Point HongKong Tel 1 847 478 2100 Tel 852 2887 8870 Brazil MELCO TEC Rep Com e Assessoria China Ryoden Automation Shanghai Ltd Tecnica Ltda 3F Block5 Building Automation Rua Correia Dias 184 Instrumentation Plaza 103 Cao Bao Rd Edificio Paraiso Trade Center 8 andar Shanghai 200233 China Paraiso Sao Paulo SP Brazil Tel 86 21 6120 0808 Tel 55 11 5908 8331 Taiwan Setsuyo Enterprise Co Ltd Germany Mitsubishi Electric Europe B V German 6F No 105 Wu Kung 3rd RD Wu Ku Branch Hsiang Taipei Hsine Taiwan Gothaer Strasse 8 D 40880 Ratingen Tel 886 2 2299 2499 GERMANY Korea HAN NEUNG TECHNO CO LTD Tel 49 2102 486 0 1F Dong Seo Game Channel Bldg U K Mitsubishi Electric Europe B V UK 660 11 Deungchon dong Kangsec ku Branch Seoul Korea Travellers Lane Hatfield Herts AL10 Tel 82 2 3660 9552 8XB UK Singapore Mitsubishi Electric Asia Pte Ltd Tel 44 1707 276100 307 Alexandra Road 05 01 02 Italy Mitsubishi Electric Europe B V Italian Mitsubishi Electric Building Branch Singapore 159943 Centro Dir Colleoni Pal Perseo Ingr 2 Tel 65 6473 2308 Via Paracelso 12 20041 Agrate B Thailand F A Tech Co Ltd Milano Italy 898 28 29 30 S V City Building Office Tel 39 039 6053344 Tower 2 Floor 17 18 Rama 3 Road Spain Mitsubishi Electric Europe B V Spanish Bangkpongpang Yannawa Branch Bangkok 1012
10. E Unit mm in A1SJ71QE71N3 T RUN BUF1 O ONLINE 1 OFFLINE 2 TESTI 10BASE T Li A1SJ71QE71N3 T 34 5 k 1 36 Unit mm in 3 When connecting the twisted pair cable make the bend radius R1 scale value in the vicinity of the connector to cable outside diameter x 4 or more 13 5 A1SJ71QE71N B5 7 A1SJ71QE71N B5 RUN BUF1 RDY BUF2 ae BSY BUF3 SW ERR BUF4 COM ERR BUF5 TE BUF6 TEST ERR BUF7 CPU R W BUF8 Get A MODE O ONLINE 1 OFFLINE A 2 TESTI E STEST2 4 TEST3 5 TEST4 Co Co UI c VH A1SJ71QE71N B5 130 5 12 EE L l G i kas ica fi 9 del e L 94 7 5 34 5 Unit mm in 0 26 3 70 0 30 1 36 4 When connecting the AUI cable make the bend radius R2 scale value in the vicinity of the connector to cable outside diameter x 4 or more 6 A1SJ71QE71N B2 7 A1SJ71QE71N B2 RUN BUF1 Een Si BE SW ERR BUF4 Am n TEST ERR BUF7 CPU R W BUF8 MODE 0 ONLINE 1 OFFLINE E 2 TEST1 3 T
11. ELAND Phone 32 0 2 257 02 40 Phone 31 0 20 587 76 00 Fax 972 0 9 885 24 30 Irish Branch Fax 32 0 2 257 02 49 Fax 31 0 20 587 76 05 EE STEE Westgate SCENE INEABH d o o BOSNIA AND HERZEGOVINA Beijer Electronics AS NORWAY Cebaco Center Block A Autostrade DORA eege Aleja Lipa 56 Postboks 487 Lebanon Beirut E Ger 0 l y 98890 BA 71000 Sarajevo NO 3002 Drammen Phone 961 0 1 240 430 ax 353 0 Phone 387 0 33 921 164 Phone 47 0 32 2430 00 Fax 961 0 1 240438 MITSUBISHI ELECTRIC EUROPE B V ITALY Fax 387 0 33 524 539 Fax 47 0 32 8485 77 E AKHNATON BULGARIA Fonseca S A PORTUGAL l Zei jus Saneti 4 Andrej Ljapchev Blvd Pb 21 R Jo o Francisco do Casal 87 89 Ph ee dree BG 1756 Sofia PT 3801 997 Aveiro Esgueira AFRICAN REPRESENTATIVE cert crus Phone 359 0 2 817 6044 Phone 351 0 234 303 900 ant Fax 359 0 2 97 4406 1 Fax 351 0 234 303 910 CBI Ltd SOUTH AFRICA MITSUBISHI ELECTRIC EUROPE B V POLAND INEA CR d o o CROATIA Sirius Trading amp Services srl ROMANIA Private Bag 2016 Poland Branch Losinjska 4a Aleea Lacul Morii Nr 3 ZA 1600 Isando Krakowska 50 J ac Phone 27 0 11 977 0770 PL 32 083 Bali HR 10000 Zagreb R0 060841 Bucuresti Sector 6 Fax 4 27 0 11 977 0761 Base 0 12 JM ARD Phone 385 0 1 36 940 01 02 03 Phone 40 0 21 430 40 06 ax 27 0 Tor PR Ue s mc EE CZECH REPUBLIC Cfi tn n g SERBIA utoCont CS s r o ratt Con ngineering d 0 0
12. EST2 GC TEST3 5 TEST4 swi lla a EE Tei Sws i TE ewe oc eo OFF ON SE TA El LI Lo dE AISJTIQE71N B2 6 5 L 94 34 5 Unit mm in 0 26 8 70 1 36 Ethernet is the registered trademark of XEROX CO LTD 10BASE2 is the formal way to say Cheapernet here is no registered trademark for Cheapernet Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties NFor safe use This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc Hong Kong Ryoden Automation Ltd 500
13. PROM test Usage not impossible This is set at O on line at the time of shipping from factory 3 Communications exchange condition setting switch setting Set the conditions for data communication with other nodes Communications Gettin exchange condition Switch Sg Setting contents designation setting switch Li Selects the line processing when the TCP ine Processing Ut P time out error occurrence 951 va uM Barres wa Gre exchanging data with the remote node oN the QE71 Select the QE71 startup method method OFF Runs following Y19 initial processing request signal Reads the parameters in the EEPROM buffer memory regardless of the Y19 after power has been turned on or the module reset and then conducts initial processing of the contents Automatic start up mode setting Self start mode setting Usage not possible Fixed to OFF Selects whether to approve or forbid data arriving from the remote node when a PLC CEU exchange CPU is running Sie ON Wriingapproved Selects the initial processing starts up timing 72 Quick start starts without a delay time Set when one network is used for the entire configuration Normal start start after a delay of 20 seconds Use when the entire configurations is made up of multiple networks This is set at OFF at the time of shipping from factory 1 Setto OFF for normal use When a TCP ULP time out error error code CO32H o
14. al Model code SH 080192 For A Ethernet Interface Module User s Manual 13JR45 Conformation to the EMC Directive and Low Voltage Instruction For details on making Mitsubishi PLC conform to the EMC directive and low voltage instruction when installing it in your product please refer to Chapter 3 EMC Directive and Low Voltage Instruction of the User s Manual Hardware for the CPU module to use The CE logo is printed on the rating plate on the main body of the PLC that conforms to the EMC directive and low voltage instruction For information about conforming this product to the EMC directive and low voltage instruction please refer to Chapter 3 EMC Directive and low Voltage Instruction section 3 1 3 Cable of the User s Manual Hardware for the CPU module to use A 6 1 Overview This manual explains how to install the following Ethernet interface modules abbreviated as QE71 hereafter for QnA series PLC CPU and how to wire them with external devices After unpacking QE71 verify that the following parts are contained AJ71QE71N3 T AJ71QE71N3 T type Ethernet Interface Module 1 AJ71QE71N B5 AJ71QE71N B5 type Ethernet Interface Module AJ71QE71N B2 type Ethernet Interface Module AJ71QE71N B2 F type Connector A6RCON F A1SJ71QE71N3 T A1SJ71QE71N3 T type Ethernet Interface Module A1SJ71QE71N B5 A1SJ71QE71N B5 type Ethernet Interface Module A1SJ71QE71N B2 type Ethernet Interface Module A1SJ71QE71N B2 E ty
15. ccurs due to data transfer from remote node while this switch is set to ON run the close and open operations with the sequence program 2 Setto OFF for normal use Initial timing setting 4 Loading and Installation The following is explanations of the handling precautions and installation environment which is common to modules when handling QE71 from unpacking to installation For the details of loading and installation of the module refer to User s Manual of CPU module to be used 4 1 Handling Precautions The following is an explanation of handling precautions of the module 1 Because the case of the module is made of resin be careful not to drop it or expose it to strong impact 2 Always make sure to touch the grounded metal to discharge the electricity charged in the body etc before touching the module Failure to do so may cause a failure or malfunctions of the module 3 Execute tightening of the module s installation screws within the range indicated below Screw position Tightening torque range External power supply terminal AJ71QE71N B5 98 to 137 N cm M4 screw screw 7 1 A1SJ71QE71N B5 40 N cm M2 5 screw 1 This terminal is used as an external power input terminal for supplying power to the transceiver when being connected to a 10BASE5 4 2 Installation Environment Refer to User s Manual of CPU module to be used 5 Connection to a Network The following is an explanation of the connec
16. e conducting area directly It may cause erroneous operation or failure A 2 WIRING PRECAUTIONS NCAUTION Perform correct pressure displacement crimp contact or soldering for external wire connections using the tools specified by the manufactures Incorrect connection may cause short circuits fire or malfunction Attach connector to the module securely Be sure to fix communication cables or power supply cables leading from the module by placing them in the duct or clamping them Cables not placed in the duct or without clamping may hang or shift alllowing them to be accidentally pulled which may cause a module malfunction and cable damage e Tighten the screw within the range of specified torque If the screws are loose it may result in short circuits or malfunction Tightening the screws to far may cause damage to the screw and or the module resulting in fallout short circuits or malfunction Do not grab on the cable when removing the communication cable connected to the module When removing the cable with a connector hold the connector on the side that is connected to the module When removing the cable connected to the terminal block first loosen the screws on the part that is connected to the terminal block Pulling the cable that is still connected to the module may cause a malfunction or damage to the module or cable e Solder coaxial cable connectors properly Insufficient soldering may cause mal
17. ee Ser us ef RUSSIA Technologick 374 6 Bulevar Svetog Cara Konstantina 80 86 SR BOSA Me amianskaya abe oor 2 708 00 Ostrava Pustkovec SER 18106 Nis Pans RH Phone 420 595 691 150 Phone 4 381 0 18 292 24 4 5 GEN Far 2 595691 is Fax 381 0 18 292 24 4 5 MITSUBISHI ELECTRIC EUROPE B V SPAIN obrera DENMARK Ped SERBIA E DK 4000 Roskilde SER 113000 Smederevo DE Song Gg del Vall s Barcelona Phone 45 0 46 75 76 66 Phone 381 0 26 617 163 EE RE Far 45 046 175 5626 Fax 381 0 26 617 163 Fax 34935891579 m jer P Eesti OU ESTONIA SIMAP H i SLOVAKIA MITSUBISHI ELECTRIC EUROPE B V UE eebe oa n UK Brondi PN Phone 372 0 6 51 8140 Phone 421 0 32 743 0472 UK Hatfield Herts ALIO 8XB Far 372 06 1518149 Fax 421 0 32 743 75 20 Phone 44 0 1707 27 61 00 Beijer Electronics OY FINLAND PROCONT spol s r o Pre ov SLOVAKIA Fax 44 0 1707 27 8695 Ser i T Kapena t vila e resov Me ores CORPORATION JAPAN phone 358 0 207 463 540 Phone 421 0 51 7580611 eee Fax 358 0 207 463 541 Fax 421 0 51 7580 650 8 12 1 chome Harumi Chuo Ku Tokyo 104 6212 UTECO GREECE INEA d o o SLOVENIA Phone 813 622 160 60 5 Mavrogenous Str Stegne 11 e Ph ie 13021 I6 900 d eu dst 8100 one one MITSUBISHI ELECTRIC AUTOMATION Inc USA Fay 439 211 1206 999 Fax 386 01 513 8170 500 Corporate Woods Parkway Vernon Hills IL 60061 MELTRADE Kft HUNGARY Beijer Electronics AB SWEDEN Phone 1 847 478 2100 Fert
18. function Be sure that cuttings wire chips or other foreign matter do not enter the module Foreign matter may start a fire or cause an accident or erroneous operation A 3 Revisions The manual number is noted at the lower right of the top cover Print Date Manual Number Dec 2004 IB NA 0800309 A This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual 2004 MITSUBISHI ELECTRIC CORPORATION A 4 CONTENTS UON MR 1 2 Performance Specifications sue et eege deeg 2 3 Settings and Names of Each Pall tente ege geen 5 4 Loading and Installation EE 9 4 1 Handling Precautions EE 9 4 2 Installation EAVINOMING A E 9 5 Connection to E RENE 10 5 1 Connecting to the 10BASE T AJ71QE71N3 T A1SJ71QE71N3 T 11 5 2 Connecting to the 10BASE5 AJ71QE71N B5 A1SJ71QE71N B5 11 5 3 Connecting to the 10BASE2 AJ71QE71N B2 A1SJ71QE71N B2 11 6 External Dimensions A 5 About the Manuals The following product are available for this equipment Refer to the table given below to choose suitable manuals Detailed Manual Manual name Manual No Model code SH 080146 For QnA Ethernet Interface Module User s Manual 13JR33 Related Manu
19. in the connector rotate it clockwise by a 1 4 turn 3 Turn until the connector locks 2 4 Confirm that the connector is locked For AJ71QE71N B2 6 External Dimensions 1 AJ71QE71N3 T 3 e N Dir 4 2 106 0 17 4 17 gt AuJ71QE71N3 TS 37 5 Unit mm in 1 48 1 When connecting the twisted pair cable make the bend radius R1 scale value in the vicinity of the connector to cable outside diameter x 4 or more 2 AJ71QE71N B5 d As710 71N B5 T D ed eo ec i p 0 q je UD dite cy dek IRA I R2 ma Nnnn 2 4 2 106 14 37 5 Unit mm in 0 17 4 17 0 55 1 48 2 When connecting the AUI cable make the bend radius R2 scale value in the vicinity of the connector to cable outside diameter x 4 or more 3 AJ71QE71N B2 S e iD N AU Ditt 4 2 106 0 17 4 17 4 A1SJ71QE71N3 T Kee i a vi o 0 9 6 5 94 0 26 3 70 Kc AurtQE7IN B2
20. o not include the protruded section on the front surface AJ71QE71N3 T 0 30 kg 0 66lb A1SJ71QE71N3 T 0 18 kg External dimensions Specifications item AJ71QE71N B5 AJ71QE71N B2 A1SJ71QE71N B5 A1SJ71QE71N B2 10BASE5 10BASE2 speed Half duplex Transmission method Base band o Maximum distance Transmission 2500 m 8202 10 ft 925 m 3034 77 ft specticalions Maximum segment Get 9 500 m 1640 42 ft 185 m 606 96 ft 100 nodes per segment 30 nodes per segment nodes connection Minimum node interval 2 5m 8 20 ft 0 5m 1 64 ft MN Number of allowable B cunnscnoh Transmission SA SE Connections usable by the sequence program data storage connections memory Number of remote nodes that can be communicated in a single initial No restrictions processing EEPROM write frequency Number of occupied I O points 5 V DC internal current consumption AJ71QE71N B5 0 40A AJ71QE71N B2 0 56A A1SJ71QE71N B5 0 40A A1SJ71QE71N B2 0 53A Conheci D sub connector Male 15 pin Canhsetioneabla l AUI cable Coaxial Cable Twisted pair cable RG58A U RG58C U 12 V DC external power supply capacity for transceiver BCN connector AJ71QE71N B5 AJ71QE71N B2 250 9 84 H x 37 5 1 48 W x 106 4 17 D mm in GE ET A1SJ71QE71N B5 A1SJ71QE71N B2 130 5 12 H x 34 5 1 36 W x 94 3 70 D mm in All do not include the protruded section on the front surface AJ71QE71N B5 AJ71QE71N B2 0 33kg
21. pe Connector ABRCON F 2 Performance Specifications The performance specifications of QE71 is shown below See CPU module user s manual to be used for QE71 general specifications AJ71QE71N3 T A1SJ71QE71N3 T 10BASE T speed Communication mode Half duplex Transmission method ere Maximum distance specifications Detweeniiodes Maximum Segment 100 m 328 08 ft 3 amp 1 lenath xi Maximum number of TENE Cascade connection is a maximum 4 stages nodes connection Minimum node interval Number of allowable i T ission simultaneously open 8 connections ee y op Connections usable by the sequence program data storage connections memory Fixed buffer 1 k word x 8 Random access buffer 6 k word x 1 Number of remote nodes that can be communicated in a single initial processing EEPROM write frequenc Maximum of 10 000 times in the same area Number of occupied I O points 32 points 1 slot I O assignments special 32 points AJ71QE71N3 T 0 53A 5 V DC internal current consumption A1SJ71QE71N3 T 0 53A Connector Modular jack RJ45 Gorneetiomesbl Unshielded twisted pair cable UTP or shielded twisted pair cable STP rated in category 3 4 or 5 12 V DC external power supply Item No restrictions capacity for transceiver AJ71QE71N3 T 250 9 84 H x 37 5 1 48 W x 106 4 17 D mm in A1SJ71QE71N3 T 130 5 12 H x 34 5 1 36 W x 94 3 70 D mm in e All d
22. tion method of the QE71 to the 10BASE T 10BASES or the 10BASE2 1 Installation procedures of the network require sufficient safety measures For the execution of such operations as terminal processing of connection cable trunk line cable etc please consult with a trained professional 2 When the customer s products match the EMC instructions and the low voltage instructions for connecting QE71 use the method in 4 below to install the ferrite core 3 When there is a communication error caused by high frequency noise due to the installation environment take the following steps e The ferrite core can be installed using the steps in 4 below e When communicating with TCP IP increase the count of communication retries e When connecting to 10BASE T use a shielded twisted pair cable STP rated in category 3 4 or 5 e When connecting to 10BASE2 use a double shielded coaxial cable e When connecting to 10BASES5 or 10BASE2 ground the shield of the coaxial cable at both the local station and companion connected device Ground at a place near the connector 4 Below are the steps for installing the ferrite core based on connection to the 10BASE5 network Please install the ferrite core 1 on the side of the QE71 or external devices the AUI cables transceiver x1 It is possible to use a TDK Corporation style ZCAT 2032 0930 For 10BASE5 connection AUI cable P luc cable for 100BASE5 Ferrite core
23. tor Connector for connecting the QE71 to the 10BASE2 1 Display LED display contents Display LED Display contents When lamp islit Lamp is not lit Normal operation displa RDY Exchange ready end apy Ge SEI S display with remote node is being executed Norma Exchange processing executing ICPURW R W cpurw EX PLC CPU display Exchanging Not exchanging Display of communication line connection status of connection Open completed Closed status No n corresponding to BUFn TEST Self diagnostic executing display E D LM ERR Self diagnosis results displa BUF1 to BUF8 The order of the display LEDs is shown below AJ71QE71N3 T AJ71QE71N B5 A1SJ71QE71N3 T A1SJ71QE71N B5 AJ71QE71N B2 A1SJ71QE71N B2 RUN o BUFI RUNI O O BUF O O BUF2 RDY oO BUF2 RDY O O BUFS BSY o o BUF3 BSY SW ERR o o BUF4 t Ee COM ERR O BUER CPUR W BUF7 TEST o BUF6 O O BUF8 TEST ERR O BUF7 Ge CPU bp oO BUF8 O O O O O O TEST O oO TEST ERR O O O O 2 Operation mode setting switch setting Set the QE71 operation mode Usually set to on line Operation mode Setting Setting Setting contents setting switch number designation Performs exchange with remote node in the On line normal operation mode Off line Disconnects the local station from the network Performs a self diagnosis test using a self Performs a RAM test Performs a ROM test x mni unt Performs an EE

Download Pdf Manuals

image

Related Search

Related Contents

Homelite UT15550B Tiller User Manual  Master User Guide - Berkeley Guard Group  "user manual"        TEFAL TO101130 Instruction Manual  TAFCO WINDOWS NU2-239V-I Instructions / Assembly    

Copyright © All rights reserved.
Failed to retrieve file