Home

Instruction Manual

image

Contents

1. ASTM B499 D1400 Handling and storage The SaluTron ComBi D3 gauge is a high tech precision instruments with a wide scope of aplications It is therefore of great importance that the unit is handled with care to ensure an extended life and as a pre requisite for precise and accurate measurement results The following guidelines are to be followed to achieve the above 1 Protect the gauge against dirt and dust and do not let the gauge drop 2 Protect the gauge from dirt dust humidity chemicals and aggressive vapours 3 After use please store the gauge in the protective case 4 Avoid direct strong sunlight and temperature shocks as these can have a negative influence on the measurement result The instrument housing is resistant to most chemical cleaners use a soft moist cloth for cleaning 6 Exact measurements can only be taken with a clean probe The probe therefore has to be checked and cleaned regularly so that any paint residue and iron fragments can be removed from the probe and the ruby tip C1 info tursdaletechnicalservices co uk 7 If the gauge is not to be used for an extended period of time the battery should be removed to avoid battery acid spilage and the resultant destruction of the electronics If the gauge has a fault condition please return it to the agent who will assist you if possible or return the gauge to the factory for repair No other repairs should be attempted under any circum stances
2. 3500 my or if the gauge is placed on the incorrect substrate eg wood paper cardboard etc then the display will show InFi infinite For measurements on spinerical surfaces eg rods pipes corrugated surfaces etc the V groove will assist in the placement of the probe Do not take measurements on magnets or in magnetic fields Switching the gauge ON OFF The gauge switches on automatically when being placed on the surface and turns off automatically after about 40 sec when no other measurement is taken To switch the gauge manual by hand press the ON OFF key It shows automatically the last measuring value The device is ready for new measurement To switch off the gauge press ON OFF key approximately 5 sec Using the menu The menu can be used to configure view the following features 1 The measurement method single point measurements or continous measurements to find the coating thickness average 2 The unit for the digital read out The result can be displayed in my or in mils This is indicated by a line next to the respective unit 3 The audible tone can be switched on off 4 The serial number of the particular gauge can be viewed The menu is accessed by pressing the mode button Consecutive pressing of the mode button will cause the program to cycle through all the available parameters as mentioned above If the parameter is to be changed the Enter button is pressed Once the desired set
3. 4 x 0 4 Minimum curvature convex 5 mm or 0 02 concave 30 mm or 1 Minimum substrate thickness Fe 0 20 mm or 8 mils NFe 0 05 mm or 2 mils Temperature range Storage 10 C 60 C 14 F 140 F Operation 0 C 60 C 32 F 140 F Probes Single point Power supply 9 Volt E block alkaline Dimensions LxBxH 118x58x38 mm Weight Approx 150 g with the battery Technical data subject to change without notification In this direction will find a vision of the measurement technique http www industrial needs com measuring instruments htm info tursdaletechnicalservices co uk NOTE This instrument doesn t have ATEX protection so it should not be used in potentially explosive atmospheres powder flammable gases
4. Battery exchange The SaluTron ComBi D3 gauge is powered by a 9 V alkaline battery The battery compartment can be found in the top back portion of the instrument If a B appears in the display the battery has to be exchanged If a replacement battery is not available immediately several measurements can still be taken until the gauge shuts down the display shows BAT completely Zero calibration The gauge has to be zeroed anew when different measurement jobs are called for when the gauge is used for the first time after a new battery has been inserted or periodically Place the gauge on the iron plate or the Al plate in the instrument casa You can also use a piece of uncoated Fe or NFe metal substrate as used in your process Take care to place the probe evenly onto the substrate If the displayed value is out of the basic tolerance range the instrument has to be zeroed The following steps are to be taken to zero the gauge Remove the gauge from the zero plate or the substrate Press the top left button ZERO The display shows P O O Place the gauge onto the zero plate or the substrate again The display shows PinF and automatic the last indication Place on zero plate again The display shows 0 The unit is now ready for accurate measurements Note If the measurement is repeated on the same spot on the zero plate the gauge will not necessarily show 0 0 my mils as surface roughness and dirt etc can cause di
5. application manual or automatic go on like follow Press MODE it shows rSL Press ENTER it shows no Press MODE again it shows YES Press ENTER it shows the last measuring value in the normal measurement mode Now check the store is empty Press ON OFF it shows Ave Once more press ON OFF it shows n 0 The store is empty Once more press ON OFF The store is empty and the device is in the normal measuring mode back again Automatic or manual The store become deleted if the device is in the normal measuring mode The device is easy to operate Also the menue on the display makes all addjustments quick easy and simple System overview SaluTron amp ComBi D3 The coating thickness gauges D3 are simple costeffective handheld devices Type ComBi D3 plus RS 232 interface and memory for data logging purposes The SaluTron ComBi D3 is built for two applications The gauge SaluTron amp ComBi D3 measures all non magnetic coatings such as synthetics laquers enamels copper chromium zinc etc on steel or iron Also the gauge SaluTron amp ComBi D3 measures all isolating coatings such as laquers synthetics enamels paper glass rubber etc on copper aluminium or brass This includes eloxal coatings on aluminium as well The SaluTron amp ComBi D3 gauge posses a CE sign and conform to the following specifications DIN 50981 50984 ISO 2178 2360 2808 BS 5411 3 11 3900 c 5
6. up has been found the mode button is pressed once again to activate the desired mode For example to change the measurement method the mode button is pressed until the display shows ConT The Enter button is then pressed to toggle the display between OFF and ON OFF single point measurement ON continous measurement Once the desired mode of operation has been chosen the mode button is pressed again to activate the measuring type Display massages ErO Incorrect usage InF Incorrect substrate coating thickness out of range B Battery should be replaced soon BAT Battery needs to be replaced now Cd3 Instrument identifier SaluTron amp ComBi D3 CnT Continuously measuring mode to be used when the average coating thickness is to be found by moving the gauge around on the substrate OFF By pressing the ENTER key the ON user can toggle between the point measuring and the continuous measuring modes once the MODE key has been pressed UnT By pressing the ENTER key the user can toggle between um and mils mode once the MODE key has been pressed info tursdaletechnicalservices co uk bEP Switch the tone ON OFF for ZERRO Mode ENTER ON OFF Sn Press ENTER key The serial number is blinking GAG Switch over from Fe or NFe Press ENTER key Select Fe or NFe with MODE and ENTER key AUT Automatic identification of the substrate iron steel or non ferrous material n N
7. evice DG eieptein xcu rinier meetin ean eur t eun perve VERA Mu EEEE ERNER System overview SaluTron Combi D3 osse nodes x pRles qu ap pe yun tiene REM C EUR ER I NR DR Handling GS COT AS cu esnidosvdpt cu tiasi ded ov bc ambu Too ru SR iE n UO RR uuo Ula as MR D eE iiS Pe yg ecu are d cmn iota FO eno Gea veers enon eee nee Zero calibration oc cect ign Rance UP EUN UL UU m Taking SHS UEM E NI T TM Switching the gauge ON OFF Using th Sias be MENU MD Displ y Mass t S oense eneen eeen EAE E EE E EE REEERE WGI ISSCC ANIONS uo consueto pscos pH Papx op ida Etapa sus uxo sa oO Rap EES PECETE IKASTE RESE CURE VES NSIANYNNDDADAMNNAANFS HAHN LD info tursdaletechnicalservices co uk Switch the device on Automatic display average value Ave and number of measurements n Switch the device on the display shows Cd3 or the last measuring value Press ON OFF short the display shows Ave and measuring results measurements before Press again ON OFF it shows n N mean the number of measurements If the store should become deleted proceed as follow Importand In the normal measuring
8. fferences Operation Switching the gauge ON There are two methods to switch the gauge on 1 The gauge can be switched on manually with the ON OFF button The display will show Cd3 2 The gauge can also be placed on a test piece It switches on automatically and display also Cd3 It switches automatically off after 40 sec if no measurement is taken The gauge is now ready for use Choose the function To measure on steel or iron or on non ferrum Press button Mode Stop with pressing when shown on the display GAGU Press Enter The display shows nFe or Fe If you like the function Fe press Mode button The small n for nFe is off Press Enter button The display shows and the last result is shown on the display Press Zero button and start measuring Taking measurements Place the gauge perpendicular onto the surface of the test piece Place the probe evenly and ensure that it does not sway To get the best results place the thumb on the position indicated with the other fingers behind the gauge for balance A tone is emitted and the result of the measurement is indicated on the display info tursdaletechnicalservices co uk f the gauge is removed from the test piece prematurely or placed incorrectly or the zero calibration is attempted on the incorrect substrate then the display will show Erro error If the coating thickness exceeds the maximum range
9. s Fe and a measuring value The device is now in the normal manual measuring method To get into the manual measuring Fe orNFe method proceed as follow Press the MODE Key 2 times the display shows GAG Press ENTER it shows AUT AUTO on the display Press MODE it shows Fe AUTO Press MODE it shows nFE AUTO Press the MODE key 2 times it shows AUT and then Fe Press ENTER key it shows a measuring value The device is in the measuring mode and ready for measuring applications Press the MODE Key 2 times the display shows GAG Press ENTER it shows AUT AUTO on the display Press MODE it shows Fe AUTO Press MODE it shows nFE AUTO Press the MODE key 2 times it shows AUT and then Fe Press ENTER key it shows a measuring value The device is in the measuring mode and ready for measuring applications To go back again into the automatic measuring methode Fe or nFE proceed as follow Press MODE key 2 times it shows GAG on the display Press ENTER it shows Fe or nFE Press MODE key 2 times it shows AUT Press ENTER once more it shows Fe AUTO or nFE AUTO The device is now in the automatic application info tursdaletechnicalservices co uk Table of contents lostructi n ME ET 1 cd MR ion ZA MLN oen ESEMPIO DIE ce dd pe aan ia PER ONE UL Dd b aap Ieri pati Spa bead ud Switch the d
10. umber of measurement Ave Store is empty AUTO The device switches always automatically to Fe or NFe depending of the groundmaterial Fe or NFe rS Delete store YES Yes no No Measuring Press the MODE key after every result configuration change with the MODE and ENTER key to ensure that the gauge is in the standard measuring mode again Delivery The electronic coating thickness gauge SaluTron ComBi D3 can be used immediately upon delivery It is delivered with a carrying case which includes an enclosed zero plates a 9 volt battery alkaline and the instruction manual Option Gauge D3 plus with RS 232 connection memory transfer cable to a PC statistics function Infrared Mini Thermoprinter SP 100 Technical Specifications Substrate Steel or Iron Non magnetic metals such as zinc copper brass aluminium stainless steel Continous measuring range for both gauges 0 3500 my or 0 200mils Digital display resulution from 0 0 999 my from 1 00 3 5 mm or from 0 00 140 mils Resulution 0 1 my in the range of 0 0 99 9 my 1my inthe range of 100 999 my 0 01 mm in the range of 1 00 3 5 mm Or 0 01 mils in the range of 0 00 9 99 mils 0 1 mils in the range of 10 0 99 9 mils 1 0 mils in the range of 100 140 mils Repeatability my 2 Of 0 1000 my 3 5 of 1001 3500 my Tolerance 1 0 my or 0 06 mils Smallest measurable area 10 x 10 mm2 0
11. www pce industrial needs com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co Durham DH6 5PG United Kingdom Phone 44 0 191 377 3398 Fax 444 0 191 377 3357 info tursdaletechnicalservices co uk http www industrial needs com Manual Thickness gauge PCE CT 30 info tursdaletechnicalservices co uk Instruction Manual Coating Thickness gauge SaluTron ComBi D3 Congratulations on the purchase of our coating thickness gauge SaluTron ComBi D3 The gauge belongs to a range of non destructive coating thickness gauges It is easy annd handy to use and allows the user to make all the necessary adjustment with the aid of a manue this allows for change to be implemented quickly and simply The gauge can be used for a wide variety off applications and have a large measur ring range of 0 to 3 5 mm to offer Modern electronics and the robust casing guarantee an extended lifetime for the high precision instruments Attention Automatic selection of the measurement method magnetic or eddy current Place the device on Fe groundmaterial left on top the display shows Fe Place the device on NFe groundmaterial left on top the display shows NFe To work with the device without automatic switch over manual from Fe or NFe Press the MODE Key 2 times It shows GAG on the display Press ENTER it shows AUT Auto Press MODE it shows Fe Auto Once more press ENTER it show

Download Pdf Manuals