Modbus ActiveX User Guide - Automation Consulting Services
Contents
1. Fetch Communications 11 0 Integer Status Event Counter 1 Integer Event count Fetch Communications 12 2 x 0 Integer Byte count Event Log 1 Integer Status 2 Integer Event count 3 Integer Message count 4 Integer Array Event bytes Force Multiple Coils 15 0 Integer Starting coil address 0 Integer Starting coil address 1 Integer Number of coils to write 1 Integer Number of coils written 2 Integer Array Coil values to write packed into 16 bit integers Write Multiple Registers 16 0 Integer Starting register address 0 Integer Starting coil address 1 Integer Number of registers to write 1 Integer Number of registers written 2 Integer Byte count twice the number of registers 3 Integer Array Register values Report Slave ID 17 0 Integer Byte count for device dependent data 1 Integer Slave ID 2 Integer Run Light 3 Integer Array Device dependent data Notes t The command s reply is the same as the incoming frame Register address will be translated if 1IOMapping is True 26 MODBUS Driver ActiveX Control Baud Rate Property Integer Property M Design Time M Run Time M Persistent control BaudRate Rate Cod Sets or retrieves the current baud rate used for communications with the MODBUS device The Rate Code must be one of the integer values below Rate Code Baud Rate 0 110 1 150 2 300 3 600 4 1200 5 2400 6 4800 7 9600 8 19200 9 38400 10 57600 11 1
2. Count Integer Values Integer Array FileNo Start Count Values Usage Address of the MODBUS device that is to receive the command The reference type The number of the file to read Address of the first register within the file to read Number of registers to read Limited to 120 or less on most MODBUS devices Returns the requested registers The Read General Reference command provides a way to retrieve registers in large blocks It was originally designed to allow access to optional extended memory Contemporary MODBUS devices use this command and its companion Write General Reference for a wide variety of different functions Consult your device s documentation for details Returns 0 for success or an error code Read Input Registers Method Integer Method Command 04 Status control ReadInputRegisters Address Start Count Values Parameter Type Usage Address Integer Address of the MODBUS device that is to receive the command Start Integer The first register to read 30001 39999 Count Integer Number of registers to read Limited to 120 or less on most devices Values Integer Array Returns the requested registers Reads the contents of input registers Returns 0 for success or an error code gt For an example see Sending MODBUS Commands Read Input Status Method Integer Method Command 02 Status control ReadInputStatus Address Start Count Values Parameter Type Address Int
3. Understanding Methods ionis iicet ap itr iotb 32 Gonoerston JOICPIONS aiios aber ert i A pd sb ton Pv aep dec 32 DAPR o pM 32 Receiving and Interpreting Commands e un t esee D PR SR ARIS M MUR A 33 Reading Voluts sen AA ASA AA RA A E R i 33 Sending User Command Ssesiii ige iiae anA ear OR e esa ei Ravel EAE Urt ed e ed 33 Writing Values AA ts ace eoe epe A 33 Optional arguments 10 Cs 33 Array Lo Word Method ius 34 Fetch Event Counter Method din 34 Fetch Event Log Method ario ta e ade evt LEE dra deus 34 yon Coll Method sima taa 35 Force Multiple Coils Method iia detalles 35 Loopback Method a cespite tec duse n eiu a i 36 Read Exception Status Method aiii Ye eS eR eu hs lead Eas 36 Read General Reference Method niario cti eto edt tds Deis et cstueca dude 36 Read Input Registers Method c sete titi ener ena ok nt a Hee EUR eges 37 Read Input tatus Method iia n mina 37 Read Output Registers Method turna ticas 38 Read Output Status Method iia beds en teo bid HON DON de ley eed MOD bU 38 ReceivelVIethod asiento un dede uo estan De ci Deis aR tonem ies nd iade tab etd tatibus 39 Recervesmethod Technical IN Ote ii a 39 Receive tobas Method arcilla 40 Receive Get Byte Method 5er to eerte e n de taa da 42 Receive Ger Integer Methodus deett te das 43 Release Comins Port Method eotece t sept esee a Nn duet og n 43 Report Stave TVE c c teet eere eee oe bcd e Ini es 43 Trace String Method oit iet oen tvi oue tix tenes o ien 44 User Add Byte Meth
4. including the implied warranties of merchantability and fitness for a particular purpose Under no circumstances will the Manufacturer or Developer of the Licensed Software be liable for any consequential incidental special or exemplary damages even if apprised of the likelihood of such damages occurring Some states do not allow the limitation or exclusion of liability for incidental or consequential damages so the above limitation or exclusion may not apply to you Incorporated Driver Amendment If you own OEM Version of the ACS MODBUS driver this license is amended to provide for the free or for profit distribution of software incorporating MODBUS Driver code as follows you may distribute executable programs containing the complete and unaltered ACS MODBUS Driver Incorporated Version The Incorporated Version Libraries may not be copied sold modified distributed or used by more than one user at a time they are treated as Licensed Software as described above You can only distribute the Driver as a part of self standing executable code EXE files No royalties or additional licenses are required to distribute such standalone programs For Windows DLLs you may distribute the DLL distribution version without royalties but you may not distribute the Development VBX version It is treated as Licensed Software as described above For the MODBUS Driver ActiveX control you may distribute the ActiveX file MBDRVCTL OCX only with y
5. mbdError MB Ack MODBUS 06 Busy Rejected Message 106 mbdError MB Busy MODBUS 07 NAK 107 mbdError MB NAK MODBUS 08 Memory Parity Error 108 mbdError MB Parity MODBUS errors are handled by adding 100 to the value returned in the error frame from the MODBUS device As a consequence if you encounter an error greater than 108 subtract 100 from the number to obtain the MODBUS error identification number Such error numbers are not defined in the protocol specification so you will need to consult your device s documentation to determine their meaning 10 MODBUS Driver ActiveX Control Exceptions The OLE specification provides a way for an embedded control like the Driver ActiveX control to signal serious error conditions to its host To signal such an error condition the control can throw an exception The MODBUS Driver ActiveX control uses exceptions for serious error conditions either internal errors or problems that indicate faults in your application code For example if your code tells the Driver to send a command to an illegal MODBUS address or if you supply a parameter such as a register address with an invalid value the control will throw an exception The exception mechanism is very different from the numerical error codes used to signal communications problems An exception causes the currently executing method to abort immediately and send a special signal to the host container How the host re
6. Returns byte s from the incoming message Count Integer Optional The number of bytes to retrieve Defaults to 1 Position Integer Optional Offset from the beginning of the frame Defaults to the current position gt Intended for advanced users Retrieves one or more bytes from an incoming MODBUS message captured by the Receive method Note You must use the Receive method to capture an incoming command frame before using the ReceiveGetByte method If you call this method with no received frame in memory the Driver ActiveX control will throw an exception The ReceiveGetByte method and its companion ReceiveGetInteger allows you to step through a received MODBUS command frame one parameter at a time By default if you supply neither a Count nora Position argument the ReceiveGetByte method retrieves a single byte from the current position and advances the current position by one byte The current position used by both ReceiveGetByte and ReceiveGetlnteger starts at the first byte of user data in the frame just after the MODBUS address and command numbers If you supply a Count value greater than 1 Value will be returned as an integer array with one byte from the incoming command in each element Value 0 will contain the byte at the current position Value 1 the next byte and so on until Count bytes have been copied When the method returns the current position will be increased by Count If you want
7. contain virtually any data type The specific method for assigning an array to a Variant will depend on the host language but it is possible with any development environment that supports the ActiveX standard Once you have assigned all the parameters for your reply you can dispatch it by using the UserSendAutoParse method To create the above reply you might perform the following steps in Visual Basic Dim bv 3 As Integer status As Integer bv 0 amp HCD6B Assign coil values to an integer array bv 1 amp HB20E bv 2 amp H1B control AutoParse 0 5 Set the first parameter byte count control AutoParse 1 bv Set the second parameter the value array Send reply to command 1 Read Output Status to address 17 status control UserSendAutoParse 17 1 gt See also AutoParse Property Array ReceiveAutoParse Slave AutoParse Example Word To Array Method no return Method control WordToArray Word Values Parameter Type Usage Word Integer The 16 bit integer to break into individual bits Values Integer Array Returns the bits that make up the source word This simple method is the reverse of the ArrayToWord method It accepts a 16 bit integer and returns a 16 element integer array Each element of the Values array will contain one bit of the original word Values 0 will contain the state of Word s bit 0 the least significant bit Values 1 will contain bit 1 and so on Write General Reference
8. control reads the Control ID of the button passed to the AsyncButton property When an incoming frame is detected the Driver ActiveX sends a WM COMMAND message to the indicated target window with the command ID equal to the Control ID retrieved previously Use with Microsoft languages e WM LBUTTONDOWN This setting causes the Driver ActiveX to simulate a mouse click on the control specified with the AsyncButton property When an incoming frame is detected the Driver sends a WM LBUTTONDOWN WM LBUTTONUP pair to the target control Note The WM LBUTTONDOWN mode is highly inefficient In this mode the Driver ActiveX must send two messages to your application for each incoming frame Also the WM LBUTTONDOWN message is transmitted with SendMessage rather than the more efficient Post Message This mode is provided only to support Borland Delphi users Delphi is not responsive enough to handle more traditional methods like the default posted WM COMMAND e Other messages For all other messages the Driver ActiveX will simply post the specified message to the control set using AsyncButton This approach would typically be used when your application wishes to use a private user defined message for incoming frame notification gt See also AsyncButton Slave AutoParse Example AutoParse Property Integer Property M Run Time oldValue control AutoParse index control AutoParse index newValu This is a property
9. e Run Time The property is available when the application is running e Read only You cannot assign new values to read only properties You can only read their values e Persistent Persistent properties are stored with the Driver ActiveX control by the host environment That is their values are maintained from session to session Property Summary Here are the MODBUS ActiveX control s Properties Serial Port Parameters These properties control the operation of the serial port when communicating with the MODBUS device Changing one of these parameters will affect the next command sent by the control Note There is no way of adjusting the size of the data word MODBUS RTU mode requires 8 bit words BaudRate Sets or retrieves the communications rate CommPort Sets or retrieves the current communications port 18 MODBUS Driver ActiveX Control Parity Sets or retrieves the current Parity setting StopBits Sets or retrieves the Stop Bits setting Timeouts The Timeout properties control when the Driver determines that an incoming MODBUS frame has completed and how long the control will wait for an incoming message to begin CharTimeout Sets or retrieves the character timeout which tells the Driver when an incoming frame has been completely received FrameTimeout Sets or retrieves the frame timeout the length of time the Driver waits for an incoming MODBUS message to begin arriving Communications Tracing Communications tra
10. holding registers Returns 0 for success or an error code Write Register Method Integer Method M Broadcast Command 06 Status control WriteRegisters Address Register Value Parameter Type Usage Address Integer Address of the MODBUS device that is to receive the command Use O for broadcast mode Register Integer The register to write 40001 49999 Value Integer New values for the register 49 MODBUS Driver ActiveX Control This command writes a new value to a single output holding register Returns 0 for success or an error code MODBUS Driver ActiveX Control Index A Auto Parse parameter tablen Aa td aep Modes B Building MODBUS Driver Applications dicas C Cabin A NO E TPR Odesa te eta e o E E Ix e O oi at Exceptions Ss da H Blardwate L 66e tea A a dec I Introduction retener Ee eee NEG tec ONERE E M Methods Array tO MORI ied adu eedem O tasto Ende Feth Event Counter osetinai aia bees a ia Fetch Event Lor ar E A ARAR sid Forc Co ortae iier E t E A Force Multiple Col a TOO PDACK d douse ead Exception SEALS dit Read General References iii AAA enel i cem AAA Read Input Register diia Read TOPES TATU cM Read Output Reristers s queue a dt dte eie nee q ebd Dessus sped ide i ee dae Read Output Stats P REC ii id Receive Dia aiaa ai titi Receive Get Integer inana nnn tapes wh cose en testa A E a Pea CO dad ce cei Receive Auto PATSE m NP MOD
11. to retrieve bytes from a position other than the current position maintained by the Driver you can supply a Position argument If you supply this argument the Driver ActiveX control will begin retrieving bytes at the specified position When the method returns the current position will point just after the last byte retrieved Normally you will probably want to step through the incoming frame in order breaking out bytes and integers as needed to understand the command However you can override this stepping process by supplying a Position argument Note If you supply a Count or Position that would cause the control to try to retrieve data from before the beginning of the frame or after its end the control will throw an exception gt See also Receive ReceiveGetinteger gt See also User Frame Example 42 MODBUS Driver ActiveX Control Receive Get Integer Method no return Method control ReceiveGetInteger Value Count Position Parameter Type Usage Value Integer Returns integer s from the incoming message Count Integer Optional The number of integers to retrieve Defaults to 1 Position Integer Optional Offset in bytes from the beginning of the received frame Defaults to the current position Intended for advanced users Operates in exactly the same way as ReceiveGetByte except obviously it extracts integers instead of bytes Note This method returns a signed integer If you are extra
12. 15200 Char Timeout Property Long Integer Property M Design Time M Run Time M Persistent control CharTimeout Timeout in Milliseconds The MODBUS protocol has no explicit framing that is it does not have codes that indicate when a message begins or ends Instead the protocol relies on time Specifically the protocol says that the end of each message 1s marked by a silent period lasting for at least the length of time required to transmit two and one half characters at the current baud rate The CharTimeout property tells the Driver how long it should wait before determining that an incoming message is complete In most cases the default value of 50 milliseconds should be adequate Note This is a 32 bit quantity However if you frequently have problems receiving replies from the MODBUS device or if you are communicating at low baud rates you may need to increase this value Note that the CharTimeout value is only used once an incoming message has started to arrive The FrameTimeout property determines how long the Driver will wait for an incoming message to begin 27 MODBUS Driver ActiveX Control Reducing the CharTimeout value may provide increased throughput if you are trying to sample at the maximum possible rate However values below 50 milliseconds may cause erratic operation on some computers gt See also Frame Timeout Comm Port Property Integer Property M Design Time M Run Time M Persistent control CommPo
13. BUS Driver ActiveX Control Release Comm PO AAA AA iude edited ned 43 Report bp 43 A A M d tM LO Dee Set dee 44 User Add Presta 44 User Add ua c eM m 45 Usina tica 46 User cr I 46 Wiser Send Ut PAIBE escort eS eta obe aat eO me onu e obsit 47 Word Lo o O 48 Write General S A ert t sn oe reete pae rii irse rtp dato alius 48 Write Multiple Retener tote pia e a bibas Pte tel 49 Write de O 49 O Optional arguments dt CA 33 P O 18 A eb C JL 19 f jadderhuai m TEE 21 AsyneM xm MEM EE E 21 Auto Parse XC M 22 Bai T Mee A ARS 27 iungi nii n e E e R E R E E T en eee ee 27 Comm Pot rt 28 A A ne vate Oe ae ea cee cee ee io i 28 VO Map AAA 29 dd tK cori 29 Last For Ot Pe eiie lt fase ctis qe itd NE E ce ut t de ca fepe 29 L st Error String AC RAE A A A A erearensoes 30 ii ME 30 A inrita cco RAE canteen des ue eau veh lg dedi atone E E 30 A ence tro caet eec E e D E E eue 31 Trace FIO CC C Y e 31 52 V Variants MODBUS Driver ActiveX Control 53
14. Driver ActiveX control will use to save communications tracing output Once you have set this file and enabled tracing by setting the TraceEnable property to True the Driver will print every byte that passes through the communications port under its control to the specified file Once your program exits you can examine this file to see what exactly was sent and received for every MODBUS command issued by your program The file will contain ASCII text in a simple tabular format Tip You can annotate the Trace File contents using the TraceString method gt See also TraceEnable Property TraceString 31 MODBUS Driver ActiveX Control Methods Understanding Methods Methods act like subroutines and functions Invoking a MODBUS Driver ActiveX control method is very like calling a function within your own application For example the Visual Basic statement status control ReadInputRegisters 14 30014 5 v sends a Read Input Registers command to the MODBUS device whose address is 14 The command frame will request 5 registers starting at register 30014 The register values will be stored in the Variant v and the error code if any will be returned in the variable status Methods can have several attributes e Return type This specifies the type of the value returned by the method For communications methods this is always an integer e Broadcast Some MODBUS commands allow you to transmit in broadcast mode This mean
15. MODBUS Communications Driver ActiveX User s Manual Version 1 012 March 4 1998 Copyright O 1988 1999 Automation Consulting Services Inc All rights reserved Subject to change without notice Table of Contents SOFTWARE LICENS Eiuuii cccccccccccscsccscsccscscssssssssssssssssssscscsesssesesesessesssesssesesesessssssseees 1 INTRODUCGCTATWLI ON eieecccccceeesc ccuecece nono uc o sc nonu ve ao o a ou no n no e e a ao nau a e o iu at eua un auae 3 BUILDING MODBUS DRIVER APPLICATIONS eee eeeeeeee eese eese ee eese eese eese eese eoe 4 Driver Control TOO TOTO ao UR da NH LP PAREN A A 4 Adding the Control Lo QUE projette operie is i E EE E 4 Adding an instance of PEOR OL AA leido 4 AT VI Tu 012201 MIN oe uae a bana aea E a elon E meraeets 5 Sending MODBUS commands SAI AS pts um tee 5 Additional Capabilitiess SAR AA AA AS AAA 6 e IB LCE 7 YOU LIEN al EOS o e a Ir 7 DC SCVIGL POTE Do evet eere te ie ere tos Meeks avs Eu OE s erbe rund Son pea duet vs beech ea doler arcs 7 ZI Serial Dorf aos eese es A vost eve pete ortae vete Panos 8 HARDWARE LOCNK ecco v eo eoe oo oo oe ceo o so oe eo C oo Fe Ceo o eo oen eo oo ee oec o Sr oe ee ono eo eno ee oa eo o oo eU eio Doa eco 9 ATA WI OR A HEC TEE a aa EN E REL ERR 9 IUIUS r 10 EXCEPTION eeedco cccecece nego ec uo euo ec cone nonc eo o
16. Method Integer Method Command 21 48 MODBUS Driver ActiveX Control Status control WriteGeneralReference Address RefType FileNo Start Count Values Parameter Type Usage Address Integer Address of the MODBUS device that is to receive the command RefType Integer The reference type FileNo Integer The number of the file to write Start Integer Address of the first register within the file to write Count Integer Number of registers to write Limited to 120 or less on most MODBUS devices Values Integer Array Contains the data values to write The Write General Reference command provides a way to store registers in large blocks It was originally designed to allow access to optional extended memory Contemporary MODBUS devices use this command and its companion Read General Reference for a wide variety of different functions Consult your device s documentation for details Returns 0 for success or an error code Write Multiple Registers Method Integer Method M Broadcast Command 16 Status control WriteMultipleRegisters Address Start Count Values Parameter Type Usage Address Integer Address of the MODBUS device that is to receive the command Use 0 for broadcast mode Start Integer The first register to write 40001 49999 Count Integer Number of registers to write Limited to 120 or less on most devices Values Integer Array New values for the registers This command writes new values to output
17. ODBUS device that is to receive the command Start Integer The first output to read 1 9999 Count Integer Number of outputs to read Limited to 2000 or less on most devices Values Integer Array Returns the requested outputs Reads the status of discrete outputs coils The output states are returned packed into 16 bit integers Bit 0 the least significant bit of Values 0 will contain the state of the output designated by Start Bit 1 will contain the state of Start 1 and so on You can use the WordToArray method to break the elements of Values into individual bits 1f that is more convenient Returns 0 for success or an error code gt See also WordToArray 38 MODBUS Driver ActiveX Control Receive Method Integer Method Status control Receive Address Command Length Wait Parameter Type Usage Address Integer Returns the address the incoming command was sent to Command Integer The MODBUS command number in the incoming message Length Integer Total length in bytes of the incoming command Wait Long Integer Optional length of time in milliseconds to wait for an incoming command gt Intended for advanced users This method allows your application to receive commands from other MODBUS devices Most applications that use the MODBUS driver will act as masters They will send commands to MODBUS devices using methods like ReadInputStatus that automatically wait for and process the error and information frame sent b
18. Parse Method Integer Method length control UserSendAutoParse Address Command Parameter Type Usage Address Integer Address of destination MODBUS device Command Integer Command number to send gt Intended for advanced users The UserSendAutoParse method is the converse of the ReceiveAutoParse method It creates a reply frame based on the destination address MODBUS command number and parameters you supply You ll supply these parameters by assigning values to the AutoParse property array Let s look at the Read Output Status command A reply might look like this at the binary level Sample Value hex Type Description E Iw Ww CD6B Coils 20 35 B20E Coils 36 51 As you ll remember we were asking for 37 coils beginning with coil 20 The reply contains a byte count which tells the remote device how much data to expect The coil values follow packed into 16 bit words 47 MODBUS Driver ActiveX Control Following the logic established with the ReceiveAutoParse method the command s parameters go into the AutoParse property array The first parameter is the byte count so that will go in AutoParse 0 The second parameter is the array of coil values which goes into AutoParse l The AutoParse Property Array Transmit Parameters Table tells you what values to place in each element of the AutoParse property array for each MODBUS command reply This works because the Aut oParse property is an array of Variants which can
19. UserInit 27 amp H80 Or 4 Error code 2 MB UserAddByte 2 Eri Send the code If MB UserSend 0 Then MsgBox Error sending error MB LastErrorString _ vbOKOnly or vbExclamation Data Poll End If Else Request is legal send data Begin by setting up MB UserInit 27 4 Add byte count MB UserAddByte nregs 2 Figure out offset into value array subsc startReg 34040 For n 1 To nregs Add a value from the master array MB UserAddInteger RegisterValues subsc Next subscript subsc subsc 1 Next n Send the values If MB UserSend 0 Then MsgBox Error sending values MB LastErrorString _ vbOKOnly or vbExclamation Data Poll 16 MODBUS Driver ActiveX Control End If Legal register range End If Command we should answer End If Listening loop Wend This example code fragment makes several assumptions e The variable cancelFlag will be set to True elsewhere in the program when the listening loop is to exit e The recipe values are stored in an array called RecipeValues e There is an instance of the MODBUS Driver ActiveX control called MB on the current form The code in this example should be fairly easy to understand Basically there is a main loop that waits for incoming commands until the cancelF1ag variable becomes True In order to allow the application s user interface to continue to updat
20. ack by the slave device However you can use the Receive method to cause your application to act as a MODBUS slave The Receive method waits for a correctly formatted MODBUS command If such a command arrives the Receive method will return its MODBUS address command number and frame length in the variables listed above If no MODBUS command arrives within the time allotted the Receive method will return a Timeout error By default the Receive method waits for the length of time specified in the FrameTimeout property You can choose another wait interval by specifying the optional Wait parameter Note You do nof need to use the Receive method to obtain results from master methods like ReadInputStatus Use this method only if you want to wait for incoming commands from another device or retrieve replies from a User command Once a command has arrived you can check the Address and Command variables to see if your application should process the message You can use the ReceiveGetByte and ReceiveGetlnteger methods to break the incoming message into parameters If the application needs to send a reply it can employ the User methods Note Ifthe Receive method successfully captures an incoming frame the current position used by both ReceiveGetByte and ReceiveGetInteger will be set to the first byte of user data in the frame just after the MODBUS address and command numbers Returns 0 for success or an error code Receive m
21. acts to this signal depends on the programming language By default most languages and development environments will stop your application and display an error box when an exception occurs Depending on your programming language s features you may be able to prevent or alter this behavior C for example provides the try catch construct to handle exceptions By enclosing a Driver call in a try block you can intercept and handle any exceptions that may occur Visual Basic provides exception handling via the on error goto statement When an exception occurs after an on error goto statement control flows to the statement named in the on error command Your code can then determine what action to take and resume normal execution It should be stressed that you normally shouldn t need to worry about the exception mechanism Once your code is debugged the Driver control should never need to throw an exception If an exception does occur in debugged code the situation 1s probably very serious During debugging exceptions are actually very valuable By stopping the program and signaling a serious error the Driver is telling you that there is probably a bug in your code This makes finding errors much quicker Routine communications errors such as Timeouts and CRC errors do nof cause the Driver to throw exceptions Instead these problems are reported via the error code returned by each method Your code needs to check for and handle
22. ands If you set the AsyncHandshake property to False the serial port s RTS signal will always be true gt See also AsyncButton Slave AutoParse Example AsyncMessage Property Long Integer Property M Design Time M Run Time V Persistent control AsyncMessage Windows Message Number Intended for advanced users This property determines what Windows message the MODBUS Driver ActiveX control sends when it wishes to notify your application that an incoming command frame has arrived It applies only when you have set up asynchronous listening with the AsyncButton property By default the control uses the message WM COMMAND It reads the control ID of the button passed to AsyncButton property and uses that as the command number in the message This approach should work for all Microsoft languages 21 MODBUS Driver ActiveX Control You should only need to change this property if you are using a non Microsoft language that doesn t interpret WM COMMAND properly Unfortunately Borland Delphi is such a language It does not obey this standard Windows message For Delphi you should use WM LBUTTONDOWN You could also change this message if you wish to use a private application specific message that you have defined Advanced programmers who use languages like C frequently use this technique The Driver ActiveX handles messages in the following way e WM COMMAND The default message When this message is set the ActiveX
23. ant 0 1 mbdStops 1 1 1 5 mbdStops 15 2 2 mbdStops 2 30 MODBUS Driver ActiveX Control Trace Enable Property Boolean Property M Run Time control TraceEnable True False This property enables or disables communications tracing which is disabled by default Communications tracing allows you to see all the data that passes through the communications link in both directions It can be very useful for diagnosing difficult communications problems When communications tracing is enabled all bytes that are sent and received are recorded to the ASCII text file specified in the TraceFile property You can enable and disable tracing repeatedly as needed during a session For example you can set the TraceEnable property to True just before sending a MODBUS command that isn t working properly then set the TraceEnable property back to False before sending other commands Note The TraceFile property must be set to a legal filename before communications tracing will work Your program must also explicitly set the TraceEnable property to True before tracing will begin the TraceEnable property is not stored from session to session Tip You can annotate the Trace File contents using the TraceString method gt See also TraceFile Property TraceString Trace File Property String Property M Design Time M Run Time M Persistent control TraceFile Legal filename txt The TraceFile property specifies the output file that the
24. ariety of data types the actual type used here depends on your application You can pass a single byte a single integer a byte array or an integer array The Count parameter determines how the Value parameter is interpreted If Count is 1 or omitted the Driver will treat Value as a scalar adding its Least Significant Byte to the frame If Value is an array the Driver will add the Least Significant Byte of Value 0 to the user command frame If Count is greater than 1 then Value must be an array of integers or bytes The Driver ActiveX control will add the Least Significant Byte of Count elements of the array to the user command frame Returns the new length of the outgoing command frame Note You must set up the User command frame with the Userlnit method before you can use the UserAddByte method If you call the UserAddByte method before Userlnit the control will throw an exception gt See also UserAddinteger Userlnit and UserSend gt See also User Frame Example User Add Integer Method Integer Method length control UserAddInteger Value Count Parameter Type Usage Value See below Integer or integers to add to user command Count Integer Optional Number of integers to add Defaults to 1 gt Intended for advanced users Works in exactly the same way as the UserAddByte method but adds integers words For this method the Value parameter can contain only a single integer or an integer array Returns the n
25. array is designed to hold several parameters of varying types The exact meaning of each parameter depends on the MODBUS command being processed there is a table below that describes the parameters in detail Assuming oldValue and newValue are both Variants or Variant compatible types you can retrieve or assign values to or from the property array using the syntax above The index variable is a 16 bit integer that can range from 0 to 4 allowing five parameters in total Note that not all MODBUS commands use all five parameters Many commands need only one or two parameters 22 MODBUS Driver ActiveX Control Both the ReceiveAutoParse and UserSendAutoParse methods use the AutoParse array The ReceiveAutoParse method will decode incoming command frames and put the information that it finds into elements of the AutoParse property array The UserSendAutoParse method uses information from the property array to construct replies to incoming commands The exact use of these commands is demonstrated and explained in the Slave Mode example Note The IOMapping property affects register addresses in the AutoParse property array If TOMapping is True the MODBUS Driver ActiveX control will automatically translate register addresses 23 MODBUS Driver ActiveX Control AutoParse parameter table This table documents the AutoParse parameter configuration for all the MODBUS commands supported by the ReceiveAutoParse and UserSendAutoParse meth
26. astError Retrieves or sets the integer number of the last error reported by the Driver ActiveX control or zero if no error occurred during the last operation 29 MODBUS Driver ActiveX Control Last Error String Property Integer Property M Run Time M Read Only StringVariable control LastErrorString or StringVariable control LastErrorString errorNumber Retrieves the last error reported by the Driver ActiveX control in string format If you supply the optional argument errorNumber the Driver will return the string equivalent of the specified error number Parity Property Integer Property M Design Time M Run Time M Persistent control Parity Parity Code This property determines whether any parity bits are used during communications with the MODBUS device The Parity Code must be one of the values in the table below The default value of 0 No Parity should be used in most situations Parity Code Port Parity Constant 0 None mbdParity None 1 Odd mbdParity Odd 2 Even mbdParity_Even 3 Mark mbdParity_Mark 4 Space mbdParity Space Stop Bits Property Integer Property MI Design Time M Run Time M Persistent control StopBits Stop Bits Code This property determines the number of stop bits that are used during communications with the MODBUS device The Stop Bits Code must be one of the values in the table below The default value of 0 1 stop bit should be used in most situations Stop Bits Code Stop Bits Const
27. at is to receive the command Use 0 for broadcast mode addressed to all devices DiagCode Integer Code indicating diagnostic to run Info Integer Parameter value for diagnostic Runs a diagnostic on the MODBUS device The DiagCode parameter specifies which diagnostic to run the Info parameter may be used by some diagnostic operations and ignored by others Some diagnostic functions will return information via the Info parameter The specific diagnostics available vary from device to device but diagnostic O the Loopback test is always implemented This test simply sends back the Info value unchanged Returns 0 for success or an error code Read Exception Status Method Integer Method Command 07 Status control ReadExceptionStatus Address Value Parameter Type Usage Address Integer Address of the MODBUS device that is to receive the command Value Integer Returns the contents of the Exception register Reads the MODBUS device s Exception register Depending on the device this bits in this register may reflect error or status conditions On Programmable Logic Controllers this register is usually linked to certain specific special coils Returns 0 for success or an error code Read General Reference Method Integer Method Command 20 36 MODBUS Driver ActiveX Control Status control ReadGeneralReference Address RefType Parameter Type Address Integer RefType Integer FileNo Integer Start Integer
28. cing allows you to track every byte sent or received by the Driver ActiveX control TraceEnable Turn communications tracing on or off TraceFile Specify the output text file that is to receive the communications tracing information User Frames and Asynchronous Operation AsyncButton Designates a button to be clicked by the asynchronous notification system when an incoming frame arrives AsyncHandshake Enables or disables changes in the serial port RTS signal during asynchronous receiving AsyncMessage Specifies the Windows message used to signal incoming command frames when in asynchronous mode AutoParse Property array used to interpret incoming frames and construct replies Other Properties OMapping Sets or retrieves the I O Mapping mode LastError Retrieves the last error code encountered by the Driver LastErrorString Translate the last error code or any error code to a string AsyncButton Property Long Integer Property M Run Time oldHandle control AsyncButton control AsyncButton newHandle gt Intended for advanced users This property allows you to respond asynchronously to incoming commands Using the Receive method in the traditional way your program would have to poll for incoming 19 MODBUS Driver ActiveX Control commands That is you would have to set up a loop that would call the Receive method repeatedly until an incoming command was detected This is obviously an inefficient approach e
29. cting an unsigned integer value 8 8 y 8 8 8 you will need to perform the necessary conversion usually to a long integer gt See also Receive ReceiveGetByte gt See also User Frame Example Release Comm Port Method no return Method control ReleaseCommPort The first time that you invoke a Driver method that requires the use of the serial port the MODBUS Driver ActiveX control will automatically connect to the port and stay connected The Driver will normally maintain control of the serial port until the host application ends If you need to release the serial port perhaps so another application can use it you can invoke the ReleaseCommPort method This method causes the Driver to immediately terminate its connection to the serial port and free the port Note Ifyou change the port that the Driver is using via the CommPort property it will automatically release any connection it is currently maintaining and open the new port on the next method invocation that requires serial port access Report Slave ID Method Integer Method Command 17 43 MODBUS Driver ActiveX Control Status control ReadOutputRegisters Address SlavelD RunMode DDataCount DeviceData Parameter Type Usage Address Integer Address of the MODBUS device that is to receive the command SlaveID Integer Returns the MODBUS device s Slave ID RunMode Boolean Device is running DdataCount Integer Number of items in the DeviceData array D
30. ddresses that you pass to conform to the Protocol s specifications For example if you refer to Holding Register 40127 the actual binary address transmitted by the Driver will be 126 as defined by the Protocol However if you are not working with Gould equipment or if you need to control the actual transmitted addresses you can disable address mapping with this command I O Mapping is enabled by default To disable it set the OMapping property to False Note If you disable I O Mapping the Driver ActiveX control will perform no address range checking When I O Mapping is disabled you are responsible for supplying register and point addresses exactly as the MODBUS device will receive them Key Port Property Integer Property M Design Time M Run Time M Persistent control KeyPort Port Number For copies of the Driver ActiveX control that are protected by a Hardware Lock this command changes the printer port that the Driver searches for the hardware key The default is 0 which selects LPT1 Use one of the port number codes below Port Number Port 0 LPT1 1 LPT2 2 LPT3 The Driver will periodically check for the presence of the Hardware Lock on the port indicated by the KeyPort property If the key is not found the Driver will return an error code of 4 Hardware Key not found Note This property is not used for OEM versions of the Driver Last Error Property Integer Property M Run Time IntegerVariable control L
31. e the loop waits only 100 milliseconds 1 10 second and executes a DoEvent s call with every iteration If a command is received the code checks to see if it is addressed to the PC It also checks to make sure the command is Read Input Registers the only MODBUS command we are supporting and that the registers requested fall inside the range that we have values for that is 34040 to 34060 Assuming the incoming command passes all these tests the code constructs an outgoing reply in the correct format and sends it 17 MODBUS Driver ActiveX Control Properties Understanding Properties The MODBUS Driver ActiveX control s properties act like member variables in most languages You can assign values to them or assign their values to other variables For example the Visual Basic statement control BaudRate 7 will set the communications baud rate to 9600 7 is the rate code for 9600 baud By the same token the statement intvar control BaudRate will assign the rate code for the current communications speed to the integer variable intvar Properties can have several attributes e Type The property variable s type such as integer or string Design Time The property is available when you are designing your application The exact meaning of design time and run time varies somewhat depending on your development language In Visual Basic design time is when the application is stopped and the tool palette is presented
32. e process control logic The TDC will use the MODBUS command Read Input Registers function 4 to retrieve the recipe values from the PC so we need to listen for this command The Read Input Registers command is formatted as follows in the MODBUS protocol specification MODBUS address 1 byte Function number 1byte 4 Starting Register address 1 word Register count n 1 word The reply message looks like this MODBUS address 1 byte Function number 1 byte 4 Byte count 1 byte Data values n words Here s the code fragment that will handle the data requests from the TDC Dim addr As Integer cmd As Integer clen As Integer Dim stat As Integer startReg As Long Dim nregs As Integer n As Integer subsc As Integer While Not cancelFlag 15 MODBUS Driver ActiveX Control DoEvents stat MB Receive addr cmd clen 100 See if this is a command we should process If stat 0 And addr 27 And cmd 4 Then Retrieve the starting address MB ReceiveGetInteger addr addr is a signed integer so convert to a long VB has no unsigned 16 bit integer If addr gt 0 Then startReg addr Else startReg amp H10000 amp addr End If Read the number of registers requested MB ReceiveGetInteger nregs Is this a legal register range If startReg 34040 Or startReg nregs gt 34060 Then No send back Error Frame 2 Illegal Data Address Error frame is function number or 80H MB
33. eger Start Integer Count Integer Usage Address of the MODBUS device that is to receive the command The first input to read 10001 19999 Number of inputs to read Limited to 2000 or less on most devices 37 MODBUS Driver ActiveX Control Values Integer Array Returns the requested inputs Reads the status of discrete inputs The input states are returned packed into 16 bit integers Bit 0 the least significant bit of Values 0 will contain the state of the input designated by Start Bit 1 will contain the state of Start 1 and so on You can use the WordToArray method to break the elements of Values into individual bits if that is more convenient Returns 0 for success or an error code See also WordToArray Read Output Registers Method Integer Method Command 03 Status control ReadOutputRegisters Address Start Count Values Parameter Type Usage Address Integer Address of the MODBUS device that is to receive the command Start Integer The first register to read 40001 49999 Count Integer Number of registers to read Limited to 120 or less on most devices Values Integer Array Returns the requested registers This command reads the current contents of output holding registers Returns 0 for success or an error code Read Output Status Method Integer Method Command 01 Status control ReadOutputStatus Address Start Count Values Parameter Type Usage Address Integer Address of the M
34. er ActiveX control reports errors in two different ways by using numeric error codes and by throwing exceptions Error codes are used to report communications problems while exceptions are reserved for more severe conditions that may indicate faults in your application code For example if you send a MODBUS command and no reply is received the Driver will report a Timeout error However if you attempt to tell the Driver to send a command to an illegal MODBUS address or if you supply a parameter such as a register address with an invalid value the control will throw an exception Error codes are also used to indicate problems reported by the MODBUS device For example most MODBUS devices implement only a subset of the available commands If you use a Driver method to send a command that the device doesn t support it will return an error code Here are the currently defined error codes Error Code Constant No error 0 mbdError_None Hardware Key not found 4 mbdError_NoKey Receive Operation Failed 3 mbdError_NoRecv Could not send frame 2 mbdError_NoSend Timeout 1 mbdError_Timeout Bad frame received 1 mbdError BadFrame CRC error 2 mbdError CRC Returned Frame check failed 3 mbdError RetCheck MODBUS 01 Illegal Function 101 mbdError MB Func MODBUS 02 Illegal Data Address 102 mbdError MB Addr MODBUS 03 Illegal Data Value 103 mbdError MB Data MODBUS 04 Failure in Associated Device 104 mbdError MB Fail MODBUS 05 Acknowledge 105
35. ethod Technical Note When you call the Receive method the calling thread will block until a command is received or until the allotted timeout elapses This means no CPU time will be used but it also means that the thread will not respond to Windows messages If you use your application s main thread to call Receive and use a long timeout value the application s user interface won t update until the Receive method exits 39 MODBUS Driver ActiveX Control If your application is going to spend most of its time waiting for incoming commands you may want to place the code that calls the Receive method on an alternate thread leaving your application s main thread to handle GUI updates If you are using a language like Visual Basic which doesn t directly permit multithreading you may want to use construct like this While control Receive Address Cmd Length 100 mbdError Timeout DoEvents Wend Process the incoming command While this example considerably oversimplifies what would be done in a real application it gives the idea This performs a GUI update uses the VB DoEvents command to process messages every tenth of a second the Wait value is 100 milliseconds That will permit the application to be responsive to the user while continuing to listen carefully for incoming MODBUS commands A future version of the Driver ActiveX control will support asynchronous notification of incoming MODBUS commands but this vers
36. eviceData Integer Array Device dependent status information This command reads the MODBUS device s Slave ID and run state It also returns an array of device dependent data one byte per element The meaning of the values in the DeviceData array is completely dependent on the MODBUS device In some cases you may need to assemble two bytes into a word to get the actual value Consult your device s documentation for details Returns 0 for success or an error code Trace String Method no return Method control TraceString StringExp Parameter Type Usage StringExp Integer String to write to trace file If you have enabled communications tracing using the TraceEnable and TraceFile properties you can use the TraceString method to send any arbitrary string to the communications tracing output file This gives you a way to place comments into the trace file so you can identify the command traces See also TraceEnable TraceFile User Add Byte Method Integer Method length control UserAddByte Value Count Parameter Type Usage Value See below Byte or bytes to add to user command Count Integer Optional Number of bytes to add Defaults to 1 gt Intended for advanced users This command is used to add bytes to a User command that you are building These bytes are taken 44 MODBUS Driver ActiveX Control from the Value parameter which is a Variant Since Variant parameters can contain a wide v
37. ew length of the outgoing command frame Note You must set up the User command frame with the Userlnit method before you can use the UserAddInteger method If you call the UserAddInteger method before Userlnit the control will throw an exception gt See also UserAdaByte Userlnit and UserSend gt See also User Frame Example 45 MODBUS Driver ActiveX Control User Init Method no return Method length control UserInit Address Command Parameter Type Usage Address Integer The address to receive the MODBUS command Use 0 for broadcast mode Command Integer The MODBUS command number 0 255 gt Intended for advanced users The Userlnit method sets up the MODBUS Driver ActiveX control for the construction and transmission of a user command frame You must call this method before you can call any of the other user command methods such as UserAddByte UserAddInteger and UserSend The user command methods allow you to construct MODBUS commands that are not natively supported by the Driver You may need to use this method if your device requires nonstandard commands or if you need to reply to an incoming MODBUS command captured with the Receive method Calling the Userlnit method establishes what MODBUS command you want to send and what address you want to send the command to After calling Userlnit you can use the UserAddByte and UserAddlnteger methods to append data to the end of the command frame if any additio
38. ger For n 0 To hp Set up simple bit pattern If n And 1 Then bits n amp HCOCO Else bits n amp H505 12 MODBUS Driver ActiveX Control End If Next n hp ct 8 Calculate byte count If ct And 7 Then hp hp 1 End If B AutoParse 0 hp Set byte count B AutoParse 1 bits Set data array B UserSendAutoParse addr cmd Send the reply MB AsyncButton RTHidden hWnd Reset watcher End Sub The example code is quite simple The form s Load method initializes the serial port watcher so that any incoming command frame will cause the RTHidden Click event handler to start The event handler begins by retrieving the incoming command with the ReceiveAutoParse method If the command is not Read Output Status or the address is not 17 the handler resets the watcher and exits Next the handler reads the starting coil number and coil count In a real application the starting coil number should have some effect on the data being returned with the reply the example always returns the same data The handler creates an array of pattern data of the correct size then calculates the byte count the first parameter in the reply It sets the Aut oParse property array elements to generate the correct reply then sends the reply Once the reply is on its way the handler re enables the serial port watcher 13 MODBUS Driver ActiveX Control Variants The MODBUS Driver ActiveX control makes extensive use
39. gisters request fails st atus will be nonzero so the code fragment displays a message box The MsgBox statement uses the LastErrorString property to retrieve a text error message so the user will easily be able to tell what went wrong If the request succeeds the requested register values will be stored in the Variant V as an integer array The contents of register 30010 will be in V 0 the contents of 30011 will be in V 1 and so on The example simply uses the VB Debug object s Print method to display the contents of the 11 registers in the Immediate window Obviously a real application would display these values in a more useful way or otherwise act on the data values However the example should show you the basic procedure used when calling the MODBUS Driver ActiveX control to send MODBUS commands MODBUS Driver ActiveX Control Additional Capabilities Most MODBUS Driver applications will probably find the control s normal MODBUS command methods contain all the functionality they need Should the situation arise the Driver ActiveX control provides some specialized features e Incoming command processing Most MODBUS applications will probably operate as MODBUS masters that is they will send command and wait for replies However the Driver does support slave operation If you need to accept commands from MODBUS devices see the Receive method section e Non standard commands The MODBUS Driver ActiveX control conta
40. ible You don t want your users to be able to see the button because only the MODBUS ActiveX control will click it In Visual Basic you make a button invisible by setting its Visible property to False Within your program when you are ready to start watching for incoming commands set your MODBUS ActiveX control s AsyncButton property to the invisible button s window handle The window handle is an arbitrary 32 bit integer that has meaning only to Windows In Visual Basic this handle is exposed via the button s hWnd property Delphi uses the Handle property As soon as your program sets the AsyncButton property to the button s window handle the MODBUS ActiveX control will begin watching for incoming commands When an incoming command is detected the control will click the invisible button Your program will handle incoming commands using code attached to the invisible button s click event Within this code you might for example retrieve the command using the ReceiveAutoParse method then transmit a reply using the UserSendAutoParse method Note TheAsyncButton property must be reset after each incoming command notification This is to protect your program from having the invisible button s click event handler called during processing of a command To re enable the serial port watcher simply reset the AsyncButton property to the invisible button s window handle just as you did initially e To disable the serial port watcher se
41. ins a generous subset of the commands allowed by the MODBUS protocol If you find that the Driver does not provide a dedicated method for a MODBUS command that you need to send you can employ the User command frame methods to build and send unsupported commands MODBUS Driver ActiveX Control Cabling Normally your ACS software will be supplied with a cable suitable for connecting the IBM PC or compatible to the MODBUS device However some of our customers find that they need to make their own cables This section describes the cable and pinouts at each end of the connection The serial port pinouts are included for reference since they are not often described in computer manuals The Cable You can use the Driver with a three wire Transmit Data Receive Data and Ground cable ACS uses the following cable Conductor Signal IBMPCPin IBMATPin Device Pin 1 Ground 5 7 3 TD 3 3 4 RD 2 2 Unfortunately not all MODBUS devices have standard serial ports You may need to experiment in order to find the correct cabling setup A breakout box or similar device can be very helpful while trying to set up a serial communications link PC Serial Port The IBM PC serial port is a DB25M 25 pin Male connector Here are its pinouts pins not listed are No Connection Pin Direction 1 Shield Ground 2 Output 3 Input 4 Output 5 Input 6 Input 7 Signal 8 Input 9 Output 11 Output 18 Input 20 Output 22 Input 25 Inpu
42. ion supports only polled reception gt See also ReceiveGetByte ReceiveGetInteger See also User Frame Example ReceiveAutoParse Method Integer Method status control ReceiveAutoParse Command Address Wait Parameter Type Usage Command Integer The MODBUS command number in the incoming message Address Integer Returns the address the incoming command was sent to Wait Long Integer Optional length of time in milliseconds to wait for an incoming command Intended for advanced users The ReceiveAutoParse method is an extension of the control s standard Receive method It functions in the same general way as the Receive method except that incoming frames are subject to additional processing The optional Wait Timeout parameter has exactly the same effect as it does on the Receive method It tells the control how long to wait for an incoming command frame If this parameter is not supplied the method will wait for length of time specified by the current value of the FrameTimeout property The Command and Address parameters both 16 bit integers describe the incoming frame if one is received After a successful receive operation the Command variable will contain the frame s command number and the Address variable will contain the MODBUS node number that the command was addressed to 40 MODBUS Driver ActiveX Control As always the function s return code assigned to the variable status in this case will be zero for a
43. its for an incoming MODBUS command frame ReceiveAutoParse Wait for and interpret an incoming MODBUS command frame ReceiveGetByte Extract a byte or bytes from the incoming command ReceiveGetInteger Extract an integer or integers from the incoming command Reading Values Obtaining process data from the MODBUS device ReadGeneralReference Read data from extended memory files ReadInputRegisters Retrieve values from one or more input registers ReadInputStatus Read the status of discrete inputs ReadOutputRegisters Read values from one or more output holding registers ReadOutputStatus Read the status of discrete outputs coils Sending User Commands Creating and sending commands not directly supported by the MODBUS Driver ActiveX control UserAddByte Adds a byte or bytes to a User command being constructed UserAddInteger Adds an integer or integers to a User command being constructed Userlnit Sets up the Driver ActiveX control for transmission of a user command UserSend Transmits a user command frame UsersendAutoParse Constructs and transmits a reply to an incoming MODBUS command Writing Values Transmitting values to registers and points on the MODBUS device ForceCoil Writes a value to a single coil ForceMultipleCoils Writes values to a series of consecutive coils WriteGeneralReference Writes data to extended memory files WriteMultipleRegisters Writes new values to a series of consecutive registers WriteRegister W
44. mmand frames and send them In addition programs that use the Driver control can act as MODBUS master or slave devices either initiating or accepting commands MODBUS Driver ActiveX Control Building MODBUS Driver Applications Most applications that use the MODBUS Driver ActiveX control will perform the following steps Driver Control registration Before you can use the Driver ActiveX control you ll need to make your programming language aware of it This process is called registration Most languages provide a simple way of adding new ActiveX components to a project In Visual Basic 5 for example you can register the Driver ActiveX control by selecting the Project Components command clicking the Browse button navigating to the directory where the Driver control is located and double clicking the file MBDRVCTL OCX Other languages provide similar facilities You only need to perform this registration step once the first time you want to use the Driver ActiveX control Once the control is registered it will be available to all applications on the host system Adding the Control to your project Once the control is registered you need to add it to your project Again the exact procedure will vary according to the language but most languages follow a model similar to Visual Basic In VB5 you can add the Driver ActiveX control to a project by selecting the Project Components command and checki
45. nal data is needed Once the frame is complete use the UserSend command to transmit it Note The user command methods are needed oz y to transmit MODBUS commands not already supported by the driver You do nof need to call the User methods to use MODBUS protocol commands like Read Input Status Such commands have their own dedicated methods e g ReadInputStatus gt See also UserAddByte UserAddInteger and UserSend gt See also User Frame Example User Send Method Integer Method Status control UserSend gt Intended for advanced users Sends a user command frame that has been built with the Userlnit UserAddByte and UserAddInteger commands Returns 0 for success or an error code Note You must set up the User command frame with the Userlnit method before you can use the UserSend method If you call the UserSend method before Userlnit the control will throw an exception 46 MODBUS Driver ActiveX Control Note The UserSend method does NOT wait for a reply from the MODBUS device It simply transmits the command frame and returns If you expect a reply from the MODBUS device and you want to examine this reply you must capture and interpret it with the Receive method Note that you can simply choose to ignore any reply if you wish the MODBUS protocol doesn t require you to acknowledge incoming frames gt See also Userlnit UserAddByte and UserAddInteger gt See also User Frame Example UserSendAuto
46. ng the box next to MODBUS Driver ActiveX Control This will make the control available on the VB tool palette Adding an instance of the Control To be able to use the Driver you must add an instance of the Driver ActiveX control to your program For languages like Visual Basic this is as simple as drawing a MODBUS control on one of your application s forms The MODBUS Driver ActiveX control looks like this on the VB tool palette a Once you ve drawn a MODBUS control on your VB application s form it will look something like this e C users can create an instance of the control in one of two ways The simplest way is to draw a MODBUS control on one of your application s dialog boxes much as one would in VB When you add the Driver ActiveX control to your C project the development environment will create a wrapper class for it This class which will probably be called something like CMBDrvCt r1 allows you to access the control s properties and methods using ordinary C member functions So you can create an instance of the MODBUS ActiveX control anywhere in your program just by declaring or allocating a variable of the wrapper class MODBUS Driver ActiveX Control Setting Properties Once the control exists you can use your development environment s object inspector or property sheet examiner to set the control s basic properties such as communications port baud rate and so on These persistent pro
47. od Integer Method M Broadcast Command 05 Status control ForceCoil Address Coil Value Parameter Type Usage Address Integer Address of the MODBUS device that is to receive the command Use O for broadcast mode addressed to all devices Coil Integer Address of the coil to force 1 9999 Value Boolean Value to apply to coil Changes an output to a specific value Returns 0 for success or an error code Force Multiple Coils Method Integer Method M Broadcast Command 15 Status control ForceMultipleCoils Address Start Count Values Parameter Type Usage Address Integer Address of the MODBUS device that is to receive the command Use 0 for broadcast mode addressed to all devices Start Integer Address of the first coil to force 1 9999 Count Integer Number of coils to force Values Integer Array Values to apply to coils Changes a group of outputs to specific values The new values are supplied to the method packed into 16 bit words Bit 0 of Values 0 will supply the value for Start Bit 1 will set Start 1 and so on Bit 0 of Values 1 will set Start 16 The ArrayToWord method can be very handy for building the Values array 35 MODBUS Driver ActiveX Control Returns 0 for success or an error code gt See also ArrayToWord Loopback Method Integer Method M Broadcast Command 08 Status control Loopback Address DiagCode Info Parameter Type Usage Address Integer Address of the MODBUS device th
48. od siii tre etti iei e ae pe liu 44 User Add Integer Methode eto odia 45 User Imt NM ethoda ios ba etin d toon dome tad 46 User Send Method ainia 46 UserSendAutoParse Methods oeste queat i ehem vn bao de 47 Word To Astay Method ipao ro ot 48 Write General Reference Methods ride 48 Write Multiple Registers Method siciliana 49 Write Register o to AAA O PEE ME Hee ue ol iii 49 MODBUS Driver ActiveX Control Software License IMPORTANT The enclosed materials are provided to you on the express condition that you agree to this Software License By opening the diskette envelope or using any of the enclosed diskette s you agree to the following provisions If you do not agree with these license provisions return these materials to Automation Consulting Services Inc in original packaging with seals unbroken within 3 days from receipt for a refund 1 This software and the diskette on which it is contained the Licensed Software is licensed to you the end user for your own internal use You do not obtain title to the Licensed Software or any copyrights or proprietary rights in the Licensed Software You may not transfer sub license rent lease convey copy modify translate convert to another programming language decompile or disassemble the Licensed Software for any purpose 2 The Licensed Software is provided as is All warranties and representations of any kind with regard to the Licensed Software are hereby disclaimed
49. ods Compare the table to the Read Output Status example above to help understand it Receiving Replying Command Number Element Type Description Element Type Description Read Output Status 1 0 Integer Starting coil number 0 Integer Byte count number of coils divided by 8 rounded up 1 Integer Number of coils to read 1 Integer Array Coil values packed into 16 bit words Read Input Status 2 0 Integer Starting coil number 0 Integer Byte count number of coils divided by 8 rounded up 1 Integer Number of coils to read 1 Integer Array Coil values packed into 16 bit words Read Output Registers 3 0 Integer Starting register number 0 Integer Byte count twice the number of registers 1 Integer Number of registers to read 1 Integer Array Register values Read Input Registers 4 0 Integer Starting register number 0 Integer Byte count twice the number of registers 1 Integer Number of registers to read 1 Integer Array Register values Force Single Coilt 5 0 Integer Coil address 0 Integer Coil address 1 Integer New value 1 Integer New value Write Single Registert 6 0 Integer Register address 0 Integer Register address 1 Integer New value 1 Integer New value Read Exception Status 7 0 Integer Exception status coil value Loopback Test 8 0 Integer Diagnostic code 0 Integer Diagnostic data 25 MODBUS Driver ActiveX Control
50. of the OLE Variant data type The major reason for this is that there is no other standard way to safely pass arrays between the host application and the control Variants can contain virtually any kind of data including arrays Since a Variant containing an array provides information about the dimensions of the array the control can avoid reading or writing past the end of the array This prevents a class of severe and irretrievable crashes Illegal Page Faults The Variant data type is not as familiar to programmers as more common types such as strings and integers However it is very versatile and well suited to passing data to and from the Driver ActiveX control OLE provides standard ways to change the type of a Variant to detect empty Variants and so on For example if you pass an empty Variant to the Driver s ReadinputRegisters method the control will automatically fill the Variant with an integer array containing the register values you ve requested Visual Basic supports the Variant type directly simply Dim a variable As Variant MFC includes the COleVariant class which is a simple wrapper of a Variant If your programming language supports ActiveX controls OCXes it must provide support for the Variant data type You should consult your language s documentation for more information 14 MODBUS Driver ActiveX Control User Frame Example This example is intended to demonstrate two of the MODBUS Drive
51. our applications The printed documentation and help files are considered Licensed Software as indicated above Specifically you may not sell or otherwise distribute the MODBUS Driver ActiveX control other than with an application or for use other than as a communications component MODBUS Driver ActiveX Control MODBUS Driver ActiveX Control Introduction The ACS MODBUS Driver ActiveX Control is a software component that allows application programs written in a wide variety of languages to communicate with devices that understand the Gould MODBUS RTU protocol The Driver is provided as an ActiveX component formerly known as OLE Custom Control or OCX It allows your program to communicate with MODBUS devices by invoking methods and setting properties The Driver control handles the MODBUS protocol implementation variable conversion error checking serial port management and so on Information is passed to and from the control and hence the MODBUS device using the host language s native variable types The Driver ActiveX control can be used with any language or development environment that supports ActiveX controls including C Visual Basic Delphi and many others It supports the Microsoft Windows 95 and Windows NT operating systems The Driver directly implements all the commonly used MODBUS commands If your application requires non standard commands the control provides methods that allow you to build your own MODBUS co
52. perties will be saved with the control and hence be remembered from session to session If your application will not be changing these properties it makes sense to set them once and store them with the control rather than setting the properties each session under program control Sending MODBUS commands If the communications parameters are set you are ready to send MODBUS commands The Driver ActiveX control has methods for the most commonly used MODBUS commands To send a command you simply need to invoke the correct method For example let s suppose that you want to read the current contents of Input Registers 30010 through 30020 from a MODBUS device whose address is 9 Consider the following Visual Basic code fragment Dim status As Integer V As Variant n As Integer status MB ReadInputRegisters 9 30010 11 V If status lt gt 0 Then MsgBox Read Input Registers failed error MB LastErrorString _ vbOKOnly Or vbExclamation Read Input Registers Test Else For n 0 to 10 Debug Print 30010 n V n Next n End If Note This code assumes that the current form contains a MODBUS Driver control named MB The code segment begins by requesting the values of 11 Input Registers starting at 30010 from the MODBUS device whose address is 9 using the ReadInputRegisters method When the method returns the variable status will contain either 0 for success or an error code If the Read Input Re
53. r ActiveX control s more advanced capabilities incoming command processing and user command frames Note You do not need to use the Receive or User commands to issue and receive standard MODBUS commands Use the dedicated methods for this For this example let s assume that we need to write an application that will let a PC pass information to a large plant wide control system such as a Honeywell TDC 3000 The PC will act as an operator terminal that allows plant personnel to change recipe variables for a process The PC will maintain a set of recipe variables that can be altered by the program s operator the TDC will retrieve these values and use them to operate the process it controls Rather than trying to write the recipes into the controller we ve decided to let the TDC poll the PC for recipe values at its own convenience This makes the operator terminal program look like any other device under the TDC s control To do this we ll need to accept requests for recipe values from the TDC and send back properly formatted replies Further our program should only accept and reply to commands it understands that have been sent to its assigned address Let s set some parameters We ll say that the PC has the MODBUS address 27 and that the values the TDC will retrieve are stored in registers 34040 through 34060 The TDC will be programmed to request these registers from the PC at a regular interval and incorporate the values into th
54. r Address of the MODBUS device that is to receive the command Use O for broadcast mode addressed to all devices Busy Boolean Flag indicates that a previous command is still being processed Events Integer Count of MODBUS commands successfully processed by the device Retrieves the MODBUS device s Busy flag and Event counter You can use the Event counter to tell when commands have completed successfully This is a good way to detect when commands that require substantial processing time have finished Returns 0 for success or an error code Fetch Event Log Method Integer Method M Broadcast Command 12 Status control FetchEventLog Address Busy EventCt MsgCt Log Parameter Type Usage Address Integer Address of the MODBUS device that is to receive the command Use 0 for Ld manda laddannan A SS 34 MODBUS Driver ActiveX Control broadcast mode addressed to all devices Busy Boolean Flag indicates that a previous command is still being processed EventCt Integer Count of MODBUS commands successfully processed by the device MsgCt Integer Number of events in the Event Log Log Integer Array Contents of the event log one byte per element Retrieves a MODBUS device s Event Log Each entry in the log will occupy one element of the Log array The exact meaning of these entries will depend on the device Usually but not always these are byte wide bitmaps Returns 0 for success or an error code Force Coil Meth
55. rites a new value to a single register Optional arguments in C C C and C like languages support optional OLE parameters only indirectly You cannot simply omit an optional parameter and expect the program to work properly Technically optional OLE parameters are passed as const FAR VARIANT that is a reference to a Variant You must supply a Variant whether you want to use the parameter or not 33 MODBUS Driver ActiveX Control To indicate that an optional parameter is omitted you should set the Variant s type to VT EMPTY or VT ERROR Officially Microsoft recommends If an optional argument to an Automation method is left blank do not pass a VARIANT of type VT EMPTY Instead pass a VARIANT of type VT ERROR with a value of DISP E PARAMNOTFOUND 0x80020004L Array To Word Method no return Method control ArrayToWord Values Word Parameter Type Usage Values Integer Array Bit values to combine Must have at least 16 elements Word Integer Variable to contain combined bits Combines the bits in the input array Values into the single 16 bit integer Word Element 0 of Values becomes bit 0 of Word element 15 of Values becomes bit 15 of Word Note Any non zero element of Values will become a 1 in the output word Fetch Event Counter Method Integer Method M Broadcast Command 11 Status control FetchEventCounter Address Busy Events Parameter Type Usage Address Intege
56. rt Port Number Sets or retrieves the current port used for communications with the MODBUS device The port number must be one of the integer values below Port Number Port Constant 0 COMI mbdCom 1 1 COM2 mbdCom 2 2 COM3 mbdCom 3 3 COMA mbdCom 4 4 COM5 mbdCom 5 5 COM6 mbdCom 6 6 COM7 mbdCom 7 7 COM8 mbdCom_8 The number of communications ports supported by your system will vary Many computers don t support COM ports beyond number 4 Frame Timeout Property Long Integer Property M Design Time M Run Time M Persistent control FrameTimeout Timeout in Milliseconds This property determines how long the control waits for an incoming MODBUS message to begin either in response to an outgoing command or while listening for an incoming command When you transmit a MODBUS command using any of the Driver s command methods it will wait for a reply to begin arriving for the time specified by the FrameTimeout property Once the reply begins to arrive the control uses the CharTimeout property to detect when the incoming message is complete If no incoming message begins arriving during the time specified by the FrameTimeout property the control returns a Timeout Error See also Char Timeout 28 MODBUS Driver ActiveX Control I O Mapping Property Boolean Property M Design Time M Run Time M Persistent control lOMapping True False Normally the Driver ActiveX control maps the Register and Coil a
57. s that all connected devices will receive and act on the command Note that the official MODBUS protocol specifies that only a handful of commands permit broadcast mode e Command number Methods that transmit MODBUS commands show the decimal command number that will actually be sent Some MODBUS devices specify the commands they accept by number rather than by name Note Inthe method descriptions below variables that will be modified by the MODBUS Driver ActiveX control appear in underlined type Conversion Functions Convenience functions for manipulating data ArrayToWord Converts an array of 16 integers to a 16 bit word WordToArray Converts a 16 bit word to a 16 element integer array Diagnostics Detecting the state of the MODBUS device and discovering error conditions FetchEventCounter Retrieves the count of successfully executed MODBUS commands FetchEventLog Retrieves a log of information about all MODBUS transactions Loopback Test communications link and or retrieve diagnostic information ReadExceptionStatus Retrieves the state of the device s special status coils ReportSlavelD Determines the slave device s type and run state ReleaseCommPort Terminates the Driver s control of any serial port it is currently using TraceString Writes a text annotation to the Communications Tracing file 32 MODBUS Driver ActiveX Control Receiving and Interpreting Commands Accepting MODBUS commands from a remote device Receive Wa
58. specially in a GUI application In languages like Visual Basic the application will become unresponsive if you put the program into a tight loop on the Receive method Languages that don t support multithreading can have serious difficulties handling this sort of situation The AsyncButton property is designed to permit your application to invoke the Receive method only when you know that a command is actually arriving Until a command is detected your program can go about its business The AsyncButton property is intended for languages such as Visual Basic and Delphi that have no inherent support for multithreading and no easy way to accept arbitrary messages from the operating system Technically AsyncButton sets up a worker thread that watches the serial port When an incoming command is detected this thread sends a message to your application that has the effect of clicking a button on your program s form When your application gets this message it s time to invoke the Receive or ReceiveAutoParse method to accept and reply to an incoming command During the interval when no commands are arriving the MODBUS ActiveX control s watcher thread consumes no CPU time Using AsyncButton is a very efficient way to create an application that operates as a MODBUS slave especially when coupled with the ReceiveAutoParse and UserSendAutoParse methods To use AsyncButton begin by creating a button on your application s form then make the button invis
59. successful operation or an error code otherwise If the control successfully receives a MODBUS command during execution of the ReceiveAutoParse method it will examine that command The control has built in templates that tell it how to interpret the most popular commands These templates tell the control the construction of each MODBUS command As an example let s take the ReadOutputStatus command Oversimplifying a bit at the binary level ReadOutputStatus command looks something like this Sample Value hex Type Description 0013 Starting coil number 0025 Number of coils to read If this command were received by the ReceiveAutoParse method the command parameter would be set to 1 for Read Output Status and the address parameter would be set to 17 11 hex From this information your application will know how to process the command For example if your application has the address 17 decimal you might process the command otherwise you might ignore it Once you decide to process the command the function code 1 tells you that the remote device sent the Read Output Status command This would presumably tell your program what kind of data to include in the reply To create a reply your program will need to know what coils the remote device is requesting and how many To get this information you ll use the Aut oParse property array The ReceiveAutoParse method uses its templates to examine incoming commands The templa
60. t Signal Transmit Data Receive Data Request to Send Clear to Send Data Set Ready Ground Carrier Detect Transmit Current Loop Transmit Current Loop Receive Current Loop Data Terminal Ready Ring Indicator Receive Current Loop Note Only strictly IBM compatible serial ports implement the 20ma current loop interface 7 MODBUS Driver ActiveX Control AT Serial Port The IBM PC AT serial port is a DB9M 9 pin Male connector Here are its pinouts Pin NO AN DN BP Q Ne Direction Input Input Output Output Input Output Input Input Signal Carrier Detect Receive Data Transmit Data Data Terminal Ready Ground Data Set Ready Request to Send Clear to Send Ring Indicator MODBUS Driver ActiveX Control Hardware Lock Unfortunately software piracy is a problem that plagues all program developers the temptation to copy an unprotected disk is great and there is little actual danger to the pirate But copy protection often offends users and sometimes involves unnecessary hassles In order to keep everyone honest with a minimum of trouble for the user ACS has decided to issue all of its single user Driver products in copy protected form Note OEM versions of the Driver ActiveX control are not copy protected Hardware Lock A Hardware Lock protects the single user Driver Programs protected with a Hardware Lock come on ordinary floppy diskettes You can and should make backup copies of the pro
61. t the AsyncButton property to zero 20 MODBUS Driver ActiveX Control gt See also AutoParse Property Array RecervedutoParse UserSendAutoParse AsyncMessage AsyncHandshake AsyncHandshake Property Boolean Property M Design Time M Run Time M Persistent control AsyncHandshake True default or False gt Intended for advanced users When operating in asynchronous mode the MODBUS ActiveX control normally provides the signals needed for hardware handshaking When an incoming frame has been detected the control lowers the RTS signal until your code returns to the asynchronous listening mode When used with a device that supports hardware handshaking this feature permits you to avoid receiving additional incoming frames while you are processing a frame The RTS signal tracks your application s handling of the incoming command it will be true when you are ready to receive an incoming frame and false while you are processing a frame This type of handshaking will have no effect on MODBUS devices that don t support RTS CTS handshaking In fact many MODBUS devices are connected using a three wire transmit data receive data ground cable However if you are writing a program that operates as a MODBUS slave you may find it worthwhile to investigate hardware handshaking This will enable you to process commands more reliably especially if your application performs extensive processing or screen updates in response to incoming comm
62. te tells the method the number of parameters included in the command and the type of each parameter In our example the Read Output Status command there are two parameters the starting coil number and the number of coils to read The ReceiveAutoParse method assigns each parameter in the incoming command frame to a member of the Aut oParse property array In this case AutoParse 0 would get the value 19 13 Hex which is the starting coil number AutoParse 1 would get the value 37 25 Hex the number of coils to read ReceiveAutoParse works the same way with all the commands that it has templates for each parameter in the incoming command is assigned to a successive element of the Aut oParse property array This means that you can interpret any supported incoming command just by reading the command number which will tell you how to act on what you get and by accessing elements of the AutoParse property array e The AutoParse Received Parameters table shows what information appears in each member of the AutoParse property array for each MODBUS command 41 MODBUS Driver ActiveX Control Obviously you ll need to send a reply to the incoming command To do that you ll use the UserSendAutoParse method gt See also AutoParse Property Array Slave AutoParse Example UserSend Auto Parse Method Receive Get Byte Method no return Method control ReceiveGetByte Value Count Position Parameter Type Usage Value Integer
63. tected files using the DOS diskcopy command if you wish The protection is incorporated into the files themselves and into the locking device The Hardware Lock itself is a small device resembling a gender changer It has two 25 pin connectors on it one male and one female When you run a program protected with a Hardware Lock the software will periodically examine your computer s parallel printer port If the correct Hardware Lock is found the program runs normally If the locking device is not present the program will not operate To use the Hardware Lock simply copy the original program diskettes into a directory on your hard disk Next plug the male end of the Hardware Lock device into your computer s parallel printer port LPT1 If there is a printer already attached to your system simply plug its cable into the female end of the Hardware Lock Once you have attached the locking device you are ready to run the software Your computer should operate just as before the device is only active when the software specifically queries it The Lock is also transparent to printing By default the Driver looks for the Hardware Key on printer port LPT1 To change the port where the key is found use the KeyPort property If you are using the default port LPT1 there is no need to set the KeyPort property The Driver will return an error code of 4 if the key is not detected MODBUS Driver ActiveX Control Error Codes The MODBUS Driv
64. these errors obviously but you probably don t need to worry about exception handling for most applications 11 MODBUS Driver ActiveX Control Slave AutoParse Frame Example This example shows how one might process incoming MODBUS commands The code acts as a MODBUS slave device For the purposes of this example this code responds on y to Read Output Status commands addressed to MODBUS address 17 All other commands and addresses are ignored The example returns a simple bit pattern regardless of the address requested In a real application you would obviously want to use the starting register address to determine what data gets sent This code assumes that the form contains e A MODBUS ActiveX control called MB e A hidden button called RTHidden Private Sub Form Load Start the serial port watcher by setting the AsyncButton property to the invisible button s window handle MB AsyncButton RTHidden hWnd End Sub Private Sub RTHidden Click Read commands Dim rc As Integer Dim addr As Integer cmd As Integer Dim startCoil As Long ct As Integer Dim hp As Integer rc MB ReceiveAutoParse addr cmd If addr lt gt 17 Or cmd lt gt 1 Then Exit Sub Not a command we care about MB AsyncButton RTHidden hWnd Reset watcher End If startCoil MB AutoParse 0 Read starting coil number ct MB AutoParse 1 Read count hp ct 16 Make array for bit values ReDim bits hp 1 As Inte
65. tu nu one eoa aa e euo aad vu aa e uc o n va aoa naa aaa vn aan 11 SLAVE AUTOPARSE FRAME EXAMPLE e eee eee eee teet teet ee tees eee eoos 12 VARIANT SAA TN 14 USER FRAME EXAMNMPBLP eeeu co vesc ecco occi cu co ou cc oo oo ot c oo oo oo i6 o oo oo a6 oo o ot o oo eoe one een aga 15 PROPERTIES pm Szosa 18 Understanding PIODerOeseseses ebat day Na 18 Property Mi aii ovium te Vi masa Gau E eco ps vp di liar 18 Serial Port Parameters de bt tot nt E ded te e p dp b tete be d glass 18 TIMES Dre 19 Communications ITA io etae brio tela o eii eb beri ete ove 19 User Frames and Asynchronous O PAGO A ertet eite too eie nba 19 Other Properties AAA AAA AAA A 19 Async Button Property asses uo Rte Ge ated n edt ent iba tomi 19 AsyncHandshake Proporta 21 Asc Message ropa ees tutor ta dct tie 21 Auto Parse POPE LEY oe o edat itti ea be todo Mb e ATE 22 Auto Raise parametertable cuestas itu ied 25 Baud Rate Propecia req onec tonii idt a mee gue QOO UA WO Md areas 27 Char Timeout Property ono tdm dio oh p tte De etim cat 27 Comi Port trop rail da 28 Frame Timeout Propia Ne ey utente e mon 28 VO Mapping Prop oa 29 Key Pott Property M 29 Last EMOL Property A AE aan 29 East Error String Propecia 30 Parity Propertysia A AAA 30 St p Bits Property AAA a tef RR petii 30 Trace Enable Properties ins nao 31 Trace File PRO Pettey conces estote etm etd A ER RATEN 31 METHODS asistan ii ia 32