Home

Web Power Switch II

image

Contents

1. Link 2 etc You may change the name and destination URL for these links on the Setup page These links are convenient for connecting to other power switches or to remote sites A 6 ers Nu WEB POWER SWITCH Switching Outlets on and Off The outlet control page lets you control any switched outlet but not the always on pair The sequence delay in which outlets will be switched on is determined by settings on the setup page To switch an outlet on or off simply click to the right of the outlet name or number Switching is immediate You may also Cycle a device which is connected to the switch This feature is useful for rebooting Ethernet devices which may interrupt the web link to the switch Clicking Cycle switches power off waits a few seconds and then switches power back on This resets the attached device You may also cycle all outlets using the Cycle all outlets button on the bottom of the page Depending on your web browser settings you may need to click the refresh button to update the on screen status display after changing settings Most browsers update automatically after one minute Setup Page The settings page allows the administrator to configure the power switch These settings are supported Switch and Outlet Names Use the switch name fields to assign a Switch Name to the power switch itself Examples are Server Rack Power Strip or Plutonium Refinery Control
2. The Switch Name field appears on the top of the home page Assign a separate name to each outlet such as Missile Launcher or Email Server to make identification of each circuit simple A 7 ers Nu WEB POWER SWITCH Power On Sequence Delay When a time value is entered in the All ON sequence delay field the power switch will pause for a period of time before switching each outlet on in sequence This delay helps prevent the power surges and blown circuit breakers which can occur when multiple devices are switched on simultaneously A delay of 60 seconds is suggested for server applications You may also enter a screen refresh delay If Enable screen refresh is checked and a delay value is entered your browser should periodically update the status screen Power Loss Recovery Modes The power loss recovery mode setting has three settings which take effect after a power failure 1 You can turn all outlets off all systems will be switched off until manually turned on later by checking the first box 2 You can automatically turn all outlets on using the All ON sequence delay described above Check the second option to do this 3 You can return to the same outlet settings that were used prior to the power loss The All ON sequence delay will also be used in this instance User Defined Links You may link to other power switches your own web pages or remote web sites by entering up to four URL
3. Web Power Switch User s Guide Revision LPC 2 A 1 BERDE mo WEB POWER SWITCH Standard Features Congratulations on your purchase The web power switch is a cost effective AC power switch for remote control and reboot Web Interface The internal web server is accessible from any standard web browser Enter an IP address and the switch may be configured and controlled via the web 8 Switched Outlets 2 Un switched Outlets Eight switched circuits are provided each with a switched outlet Two un switched circuits power always on devices Line voltages from 90 240VAC voltage are detected automatically just plug it in A long 12Ga cord and 15A breaker provide protection for all 10 outlets Security Features Password Security HTTP Port and Subnet Restriction Password security limits access to the switch A changeable HTTP port makes the switch virtually impossible to access without knowing your custom URL Subnet restriction restricts control to your LAN Sequenced On Timer A programmable delay timer allows outlets to be switched on in sequence rather than simultaneously Most electrical devices draw more power when they are initially switched on Using this timer more equipment can be attached to a single circuit without overload Flash Firmware Upgrades via Ethernet Upgrade FLASH via Ethernet as new features become available At DLI we listen to customers Send your suggestions to engineering digita
4. on off pulse status gt n exit 1 Sepc Sauth splice ARGV 0 2 Sbase http Sauth R Sepc foreach ARGV _ 1c s 1 8 a 1 if 1 8a on5 RelLink outlet 1 ON elsif 1 8a of f RelLink outlet 1 OFF elsif 1 8a pulse RelLink outlet 1 CCL elsif 1 8a status n 1 defined response amp amp S response gt content lt a href outleto RelLink Scontent response gt content while content lt a href outlet 1 8 on off gt ig N 11 ers Mu WEB POWER SWITCH if 1 eq n if 2 eq ON print 1 OFF n else print 1 ON n n eq a else die Unknown command n sub RelLink local print STDERR Sbase _ n Sresponse ua gt get Sbase Sresponse gt is error amp amp die response gt status_line A 12 ers Nu WEB POWER SWITCH Limited One Year Warranty The terms of this warranty may be legally binding If you do not agree to the terms listed below return the product immediately in original unopened condition for a full refund The purchaser assumes the entire risk as to the results and performance of the unit DLI warrants this power switch to be free from major defects No agency country or local certifications are included with this unit lt is the responsibility of the user to obtai
5. Clara CA 95051 FAX 408 541 8459 www digital loggers com 2008 DLI This product may be protected under US patents 5 777 811 and 5 680 555 Additional patents pending Release 2 3 9 Monday October 13 2008 13 ers Mu WEB POWER SWITCH
6. after all users log out or after 30 minutes of inactivity This LED also blinks to display any network activity A 9 ers Nu WEB POWER SWITCH Your switch employs javascript encryption and secure challenge response authentication This gives it good out of the box security Adding additional security takes just a moment Changing the Password It s a good idea to change your password for better security Change iton the setup page and write it down in a safe place Restricting Subnet Access To restrict access to your local LAN or Class C check the subnet access setting on the setup page Changing the HTTP Port Changing the HTTP port makes it almost impossible for a hacker even one with your password to find your switch Installing Inside a Firewall Install your switch inside a firewall rather than directly on the internet for an additional layer of security A 10 ers Nu WEB POWER SWITCH Remote Control from your Application The switch can be easily controlled from your application or a command line using the PERL script below Download it from www digital loggers com Ipcperl txt usr bin perl w SD NN A E E A A e A VE ct VA PA E va eie a ed AA A MR Ee ei use LWP UserAgent pS A eee eee ee a q ee eee ee Sua LWP UserAgent gt new A de a ee ee i ad ee CV EN A A A RS Ta a ld a pa if S ARGV lt 1 print STDERR Usage UserUtil lt Host gt port lt login password gt lt n
7. bar If the login page doesn t appear follow the network setup instructions 4 Login using the default user name admin lower case Enter the default password 1234 5 Use the setup page to add outlet names or change the IP address 6 Set the recovery mode for safety after a power failure 7 Change the password for improved security Tip A lamp outlet tester or small appliance is handy for testing the switch This ensures that the switch has been configured properly before attaching your equipment Windows IP Setup 2000 2003 XP Vista If your default Windows settings won t access the switch use a crossover cable and follow these steps to reach the switch i 4 ers Hu WEB POWER SWITCH 1 Before adding an IP close network programs and browsers Go to the Network Settings Local Area Network 2 Use the keyboard shortcut lt Windows R gt type ncpa cpl and click OK 3 Right click on your LAN connection and choose Properties Highlight Internet Protocol and click the Properties button 4 Click the Advanced button Under the IP Address settings click the Add button 5 Enter a new IP such as 192 168 0 10 and a subnet mask of 255 255 255 0 Press the Add button This new IP is added the list 6 Close all windows for the configuration to take effect Start your Browser and type 192 168 0 100 in the URL field The login page should now be displayed The defaul
8. l loggers com Since we re constantly adding and changing features specifications are subject to change without notice i 2 ers Nu WEB POWER SWITCH Optional Product Features Factory included options are o Internal Auto Ping to automatically monitor servers o Internal high current MOV Surge Protection User installable options are o Rack Mount Bracket 19 Factory mail in options are o EEPROM Memory Expansion 39 These features and this manual apply to the second upgraded version of this product P N LPC2 For early units download www digital loggers com lpcman Important Factory Defaults DEFAULT IP ADDRESS The factory default IP address is 192 168 0 100 DEFAULT LOGIN User name admin lower case Password 1234 To reset the IP address and login to defaults e Switch the unit on e Gently depress the reset switch with a pen for 2 seconds e The OUTLETS ON and REMOTE ACCESS lights will flash A 3 ers Mu WEB POWER SWITCH Note This resets the admin login and IP address but it won t affect outlet names and links Use these shortcuts if you are an experienced installer Please read the manual if you haven t connected a web accessible product before 1 Connect to your LAN Using a straight RJ 45 cable Make sure the 192 168 0 100 address is compatible with your LAN otherwise use a crossover cable directly to your PC 2 Switch the web power switch on 3 Enter 192 168 0 100 in your web browser address
9. n such certifications if they are necessary DLI s entire liability and exclusive remedy as to defective hardware shall be at DLI s option either a return of the purchase price or b replacement or repair of the hardware that does not meet DLI s quality control standards and has been returned through proper RMA procedures DLI s liability for repair or replacement is to DLI s customer ONLY WARRANTY SERVICE DOES NOT INCLUDE SOFTWARE OR HARDWARE UPGRADES No warranty service will be provided without an original invoice from DLI and an RMA number provided by technical support RMA material must be shipped prepaid to DLI RMA numbers are valid for 15 days from date of issue This warranty does not cover products modified subjected to rough handling or used in applications for which they were not originally intended No oral advice or verbal warranties made by DLIs employees dealers or distributors shall in any way increase the scope of this warranty DLI makes no warranty as to merchantability or fitness for any particular purpose DLI assumes no liability for incidental or consequential damages arising from the use or inability to use this product This warranty gives you specific legal rights You may also have other rights that vary from state to state Since some states do not allow the exclusion of liability for consequential damages some of the above limitations may not apply to you DIGITAL LOGGERS INC 2695 Walsh Avenue Santa
10. s and descriptions in the Setup page For example enter Site Two Power Switch in the description field with a URL of 192 168 0 102 These links appear on the home page Network Settings A fixed IP address network mask gateway and subnet mask must be entered in this field i 8 ers Nu WEB POWER SWITCH When changing IP addresses you may need to restart your network switch to validate the new IP on an auto configuring switch port Be sure to record the new IP address Five LEDs provide status indications Network Link Activity The green light on the RJ 45 connector illuminates when there is continuity in the network cable While the link LED shows that a cable is connected on both ends it is not a definite indication of a good connection The amber activity LED illuminates when there is any network traffic detected This traffic may not necessarily be sent to the switch Power LED The power illuminates whenever the main power switch is turned on This indicates that there is power to the main unswitched outlets Outlet ON LED The outlet ON LED is off when all outlets are switched off and none of them is going to be switched on during delayed sequence The LED blinks once for each outlet switched on according to the following graph Ela 1 co el ee ee Ls 12345678 12345678 time gt Remote Access LED The Remote Access LED lights when a non expired login session exists The light goes out
11. t user name and password are admin lower case and 1234 Basic Operation After power up the switch performs a sequence of self tests to ensure reliability After self test an internal web browser starts using the fixed static IP address selected on the setup page The switch may then be operated via a web browser To access the switch simply enter the IP address in the URL field of your web browser A 5 ers Nu WEB POWER SWITCH Home Outlet Control Page To access the home page first enter the IP address in web browser URL field then log in The home page contains links to other pages The first four are static internal links Outlet Control Clicking Outlet Control links to the home page used for manually switching outlets on and off Access to specific outlets is determined by your login Settings Clicking Settings links the administrator to a configuration page This page is used to set outlet names power on features network settings user information and passwords Help The Help link displays the latest online manual Since features are subject to change without notice this manual may not be a perfect match for your switch but the later manuals will include all legacy features Logout Logout ends the web session A login is required to reconnect Programmable Web Links Four additional user defined web links are provided on the outlet control page Factory defaults are Link 1