Home

HYDRA User Manual

image

Contents

1. cha chs che chz cha cho chio ch11 ch12 Quality 5 Bitrate 3000000 BitrateMin 0 Hnterval 0 Brightness 130 Contrast 128 Saturation 128 Hue 128 The Encoding Options page includes two groups of settings The Number of Channels may be set to either 9 or 12 When set to 12 channel mode the HYDRA will stream 12 separate video channels each running at frame rate either 6 25fps for PAL or 7 5fps for NTSC while in 9 channel mode each channel will be running at frame rate either 8 33fps for PAL or 10fps for NTSC If the Number of Channels is changed this will only take affect by using the Commit button on the System Control page this will save the system settings and then initiate a reboot of the system The physical channels allocated for each mode are as follows Channel Number 1 2 3 4 5 6 7 8 9 10 11 12 9 Channel Mode v v v v v v A Y Y 12 Channel Mode Y v v v v v v v v v Y v NOTE Hydra 003 does not have the Number of Channels selection 2010 Advanced Micro Peripherals Document version A 05 19 3 User Configuration HYDRA User Manual The Video Standard may be set as PAL NTSC or Auto The Auto mode will automatically detect and set the video standard This change will only take affect after using the Commit button on the System Control page The operating charact
2. T video detected V Blind Video The revision information displayed in the left hand panel is identified as follows Version 111 106 L_ Revision of user interface HTML screens Revision of core HYDRA Streamer software This page will display all the active channels For 9 channel mode as shown above the HYDRA uses physical channels 1 2 3 5 6 7 9 10 and 11 The single audio input is always streamed with video channel 1 For 12 channel mode all physical channels are available 2010 Advanced Micro Peripherals Document version A 05 17 3 User Configuration HYDRA User Manual System Status Advanced Micro System Status Peripherals THE EMBEDDED VIDEO EXPERTS The status of active channels is listed below Status Channel 1 Video detected V Blind Video Channel 2 Video detected V Blind Video Channel 3 Video detected V Blind Video Channel4 video detected V Blind Video Version 111 106 Channel5 Video detected V Blind Video Channel 6 Video detected V Blind Video Channel 7 Video detected V Blind Video Channel8 Video detected V Blind Video Channel9 F Video detected N Blind Video Channel 10 Video detected V Blind Video Channel 11 F video detected V Blind Video Channel 12 F video detected V Blind Video The status b
3. 28 June 2010 Minor updates GM JS AS A 03 5 July 2010 Screen updates GM JS AS A 04 20 July 2010 Image updates GM A 05 1 April 2011 Update for H 264 CODEC JS a Sv ISO 9001 REGISTERED FIRM Advanced Micro Peripherals operates a company wide quality management system which has been certified by QMS International plc as compliant with SO9001 2000 HYDRA User Manual Contents 1 ENE OCUCTION PPP 4 EEUU cu EE 5 HYDRA system ata Dance lle 6 Technical specification sn 7 Compliance specifications asco ttd adeste dedos ire aid 8 Ordening VIP EA ERROR eee RO I 9 2 ANSTANA to emmener 10 Connecting to the HYDRA video SIFBBIfBE aiite dune diet 11 Connector CS SMO Saco aloni 13 Mechanical Installation 14 3 User Configuration 16 SOLE PR EEE IZ 18 Encoding OP ONS ERE RIO 19 NEMO ella 21 SENO eat 22 HYDRA Firmware Updates ss 25 A Contacting AMP M 27 2010 Advanced Micro Peripherals Document version A 05 3 Introduction The HYDRA 003 001 is a rugged multi channel video acquisition and network streamer system The HYDRA unit can capture encode and stream up to 4 channels of video and a single channel of audio over an Ethernet LAN using a variety of compression levels and streaming rates The system is designed for video surveillance in harsh environments and is suitable for use in both static and vehicle installations The HYDRA system produces an industry standard MPEG 4
4. Saturation Saturation setting for each channel The value ranges from 0 min to 255 max The default value is 128 Hue Hue setting for each channel The value ranges from 0 min to 255 max The default value is 128 2010 Advanced Micro Peripherals Document version A 05 20 3 User Configuration HYDRA User Manual Please note any changes to these settings will take effect immediately When using the ALL function only the parameters which have changed using the drop down lists will be updated across all channels Any changes will take effect immediately Network Settings Advanced Micro Network Settings Peripherals THE EMBEDDED VIDEO EXPERTS The network settings currently used by the system are shown below Any changes to these settings will take effect immediately To permanently save the changes please use the System Control page encoding to commit the changes and restart the server Encoding Mode DHCP IP Address 192 168 1 213 Version 111 106 SubNet Mask 255 255 255 0 Gateway 192 168 1 1 Please note that changes to the RTSP and HTTP ports will only take effect after a server restart Please use the System Control page to commit the changes and restart the server RTSP Port 7070 HTTP Port 8080 Mode DHCP uses an IP address assigned by the local DHCP server Static IP uses the IP address defined by IP Address Default mode is Static IP IP Address The IP address should be entered
5. be used when ordering HYDRA 003 001 Standard AMP 4 channel video streamer system HYDRA xxx yyy Where x and y are used to uniquely identify a specific system configurations for the multi channel HYDRA system 2010 Advanced Micro Peripherals Document version A 05 9 Installation 2010 Advanced Micro Peripherals Document version A 05 10 2 Installation HYDRA User Manual Connecting to the HYDRA video streamer The front panel uses industry standard connectors for the video audio LAN network and power input The HYDRA is supplied with dust covers as shown below fitted to the video audio and network LAN connectors Only remove the dust covers from the channels to be used to ensure environmental compliance all un used channels should be fitted with the dust covers w ee lt A m o O ES Hes 9 had Q int a y Oc 3 o 2 a ro The video and audio input channels use standard 75 TNC connectors The maximum length for the video and audio cables is not specified however excessive cable lengths may impact the quality of video It is recommended that good quality 75 cable is used to connect to the video sources 2010 Advanced Micro Peripherals Document version A 05 11 2 Installation HYDRA User Manual The HYDRA should be connected to a suitable power source nominally 12 or 24v The HYDRA includes internal reverse voltage protection and t
6. www ampltd com Technical support Comprehensive technical information is available on our websites see above If you can t find the information or solution you require AMP has a team of technical support engineers embedded video experts available to provide a quick and free response to your technical queries Please submit your technical support query to the appropriate email address Technical support US Technical support UK E mail support amp usa com E mail support ampltd com 2010 Advanced Micro Peripherals Document version A 05 27
7. HYDRA 4 Channel Video Streamer USER MANUAL v aay EN 2 ey 1 i N S Advanced Micro Peripherals THE EMBEDDED VIDEO EXPERTS Definitions AMP and Advanced Micro Peripherals are the trading names for Advanced Micro Peripherals Inc and Advanced Micro Peripherals Ltd Disclaimer This document contains information on a new product Specifications and information herein are subject to change without notice AMP reserves the right to make changes to any products herein to improve functioning and design Although the information in this document has been carefully reviewed and is believed to be reliable AMP does not assume any liability arising out of the application or use of any product or circuit described herein Nothing in this document is to be taken as a license to operate under or a recommendation to infringe any patents AMP does not recommend the use of any of its products in life support applications wherein a failure or malfunction of the product may directly threaten life or injury The user of AMP products in life support applications assumes all risk of such use and indemnifies AMP against all damages All information contained in this document is proprietary to AMP and may not be reproduced or disclosed to any third parties without the written consent of AMP The circuit design EPLD programs and artworks are copyright AMP 2008 The information contained in this document has been carefully checked and is be
8. Part 10 also known as H 264 video plus audio stream using a standard RTP RTSP IP stream The I frame interval for the HYDRA may be set to zero to provide a continuous stream of full resolution frames rather than using intermediate P frames AMP can provide custom configurations subject to a minimum order quantity for the HYDRA Video Streamer Please contact our Sales team see A Contacting Advanced Micro Peripherals page 27 to discuss your requirements 2010 Advanced Micro Peripherals Document version A 05 4 1 Introduction HYDRA User Manual Features Up to 4 channels of live video inputs PAL NTSC Single channel audio input MPEG 4 Part 10 H 264 video compression option 4x Di size images at full frame rate 25 fps PAL or 29 97 fps NTSC 9 40v DC powered operation with supply protection Industry standard RTP RTSP video audio stream HTML configuration management screens Standard 10 100baseT Ethernet LAN port MIL STD 810F environmental compliance Wide operating temperature range 20 C to 50 C Environmental protection IP54 EMC CE compliant Suitable for direct connection to 12 24v vehicle power systems 2010 Advanced Micro Peripherals Document version A 05 5 1 Introduction HYDRA User Manual HYDRA system at a glance Sage IE MIL DTL 38999 compliant p RJ45 LAN port connector NOTE Not all da Tough carrying handles variations have all of E Lu these co
9. as an IPv4 dot decimal notation Default IP address is 192 168 1 123 SubNet Mask The SubNet Mask defined the logical address in dot decimal notation for the local branch of the network Default subnet mask is 255 255 255 0 Gateway The Gateway address defines the node address for router to other networks Default gateway address is 192 168 1 1 RTSP Port The transport layer port number used for RTSP commands The default port is 7070 HTTP Port The transport layer port number used for HTTP commands The default port is 8080 2010 Advanced Micro Peripherals Document version A 05 21 3 User Configuration HYDRA User Manual HTTP and RTSP addresses must be fully and explicitly defined Browser access to the user interface System Status page would be http 192 168 1 123 8080 status ph Note The IP address may be different to the example shown Similarly to access the RTSP video stream for a given channel would be rtsp 192 168 123 7070 UCO 0 t Channel number for each card 0 to 3 System card number 0 to 2 Access to each channel is defined by the following stream addresses Chan RTSP stream address Comment 1 rtsp 192 168 123 7070 UC0_0 2 rtsp 192 168 123 7070 UCO 1 3 rtsp 192 168 123 7070 UCO0 2 4 rtsp 192 168 123 7070 UCO0 3 Note The IP address may be different to the examples shown System Control The System Control pages are used to permanently save and i
10. d to Ov GND PWR connector pin A is connected to V supply 12 24v AUDIO IN The video and audio connectors should be connected with standard screw fit TNC plugs The power connector PWR is Amphenol part number 62GB 5016 10 02PB 400 The mating socket and back shell part numbers are Amphenol 62GB 56TG 10 02 S B and Amphenol 62GB 776 10 The Ethernet port connector LAN is Amphenol part number PCDRJFTV7SA1N A standard Cat5 cable can be connected directly to the RJ45 socket if required or alternatively to achieve maximum sealing compliance a mating receptacle connector such as RJF TV 6 M N 09 33 can be used to accommodate a standard RJ45 Cat5 5e cable assembly 2010 Advanced Micro Peripherals Document version A 05 13 2 Installation HYDRA User Manual Mechanical Installation The HYDRA fixing plate is a semi rigid rubber base which helps to dampen the affects of vibration and high shock incidents The fixing points are shown below 6 x 8mm dia holes EN 258mm extent of handles iu 248mm extent of TNCs 200mm 7 7 7 100mm EE 0 Bn ENSEM 37mm 0 116mm H pe ui so vici di i Le Pene 14 Document version A 05 2 Installation HYDRA User Manual 165 00mm _ 180 00mm __ gt 2010 Advanced Micro Peripherals Document version A 05 15 User Configuration The HYDRA includes a number of standard HTML configurati
11. eristics for each channel may be set individually or by using the master control ALL All Ch1 Ch2 Cha Ch4 Ch5 Che Ch7 Ch8 Ch9 Chio Ch11 Ch12 Quality 5 Bitrate 3000000 BitrateMin 0 X l Interval 0 Brightness 130 Contrast 128 v Saturation 128 v Hue 128 Quality Level Quality level value setting range from minimum 31 to maximum 5 Default quality level is 5 Bit Rate The system will always encode the channels at quality level set by the Quality Level parameter until the bit rate hits the maximum value set The value range is from 500Kbps to 5Mbps in increments of 250Kbps The system uses Hybrid Bit Rate HBR control Default bit rate is 3Mbps BitrateMin The system will always stream the channel at a minimum bit rate set by Bitratemin The value range is from Obps to 5Mbps in increments of 250Kbps Default minimum bit rate is 0 I Interval Defines the I Frame interval i e the number of frames between each I frame for standard encoding The value range is from 0 to 255 Default I Interval count is O i e I Frame only similar to M JPEG mode Brightness Brightness setting for each channel The value ranges from 0 min to 255 max The default value is 130 Contrast Contrast setting for each channel The value ranges from 0 min to 255 max The default value is 128
12. gs Password Fortimezone changes to persist across system restart the settings must be saved To permanently save the new settings please use the Commit button in the Commit tab This will also restart the server Timezone GMT Greenwich Mean Time Dublin Edinburgh Lisbon London v Time HH MM SS 16 25 03 Status Encoding Network System Date YYYY MM DD 2010 07 05 Version 111 106 Set Date Time Use browser time 2010 Advanced Micro Peripherals Document version A 05 23 3 User Configuration HYDRA User Manual The date and time may be set by manually by changing the time zone time and data and then selecting the Set Date Time button or alternatively the system can request the date and time information from the system hosting the web browser by using Use browser time Note In this case only the date and time is updated not the time zone Advanced Micro Peripherals THE EMBEDDED VIDEO EXPERTS System Control For password changes to persist across system restart the settings must be saved To permanently save the new settings please use the Commit button in the Commit tab This will also restartthe server Password Network Version 111 106 Confirm Password Set password The default password is admin The new password up to 8 characters should be entered and re confirmed The operator will be notified with an error message if the two pass
13. lieved to be reliable However Advanced Micro Peripherals Ltd AMP makes no guarantee or warranty concerning the accuracy of said information and shall not be responsible for any loss or damage of whatever nature resulting from the use of or reliance upon it AMP does not guarantee that the use of any information herein will not infringe upon the patent trademark copyright or other rights of third parties and no patent or other license is implied hereby AMP reserves the right to make changes in the products or specifications or both presented in this document at any time and without notice Warranty This product is supplied with a 1 year limited warranty The product warranty covers failure of any AMP manufactured product caused by manufacturing defects AMP will make all reasonable effort to repair the product or replace it with an identical variant AMP reserves the right to replace the returned product with an alternative variant or an equivalent fit form and functional product Trademarks Tiny486 Tiny586DX Tiny786LP Mobile786EBX Tiny886 Micro886 VAC104 VAC104plus VAC2000 The Embedded Video Experts HYDRA Streamer are trademarks of Advanced Micro Peripherals All other trademarks recognized Revision History Document version Date Comments Approved A 00 14 June 2010 Initial release waiting for final product photos GM JS AS A 01 25 June 2010 Updates to User interface screen images GM JS AS A 02
14. nnectors li SZ VID CH 1 VID CH 11 I O VID CH 12 amp o uars Rubber mounting base for improved resilience to high shock vibration conditions LED power indicator 6 to 40v power input using MIL C 26482 compliant Side rails for added connector protection of connector array Main power input locking Standard TNC connector for switch audio input 2010 Advanced Micro Peripherals Document version A 05 1 Introduction HYDRA User Manual Technical specification Video input Up to 4 channel composite video input channels Standard CCIR601 NTSC CCIR PAL Software selectable brightness contrast and saturation control 1V peak to peak 750 input impedance Video compression H 264 video compression ISO IEC 14496 10 H 264 Baseline Level 3 4 channel mode D1 size images at full frame rate Programmable I frame interval quality level and bit rate IP Stream Latency 100ms typ Based on 4 PAL channel inputs with encoding at D1 resolution full frame rate at 3Mbps channel Audio input None Audio compression None Ethernet port IEEE802 3 10 100baseT Power 9 to 40v DC 1 2A at 24v typ or 2 0A at 12v typ 30W Protected against reverse voltage over voltage and transients Environmental 209C to 50 C Passive cooling no fans Physical size Approximate dimensions 260mm length 165mm high 180mm wide Weight 4 05Kg Enclosure Anodized aluminum alloy ex
15. nvoke the main operating settings for the HYDRA system as well as set the date time information and the system Password 2010 Advanced Micro Peripherals Document version A 05 22 3 User Configuration HYDRA User Manual Advanced Micro Peripherals THE EMBEDDED VIDEO EXPERTS System Control Commit Time settings Password For configuration changes to persist across system restart the settings must be saved Status Encoding To permanently save the new settings please use the Commit button This will also restart the server Network To restart the system without saving changes please click the Reboot button System Version 111 106 The top level configuration data includes the channel operating mode and the video standard PAL NTSC These modes will only take affect after pressing the Commit button This will cause the system to permanently save the settings and re boot the system The encoder options and network settings will change immediately when changed however to save the settings select the Commit button to save and re boot the system IMPORTANT NOTE This process may take about 90 seconds It is critical that the system is NOT powered down during this update process The system should remain on until the system has re booted and the System Status screen is accessible Advanced Micro Peripherals THE EMBEDDED VIDEO EXPERTS System Control commit Time settin
16. on screens which may be accessed via the default IP address http 192 168 1 123 8080 status php use full URL The default user name is administrator while the password is admin It is recommended that the password is changed during the commissioning process to a more secure password Connect to 192 168 1 123 The server 192 168 1 123 at Multi Channel Video Streaming Server requires a username and password Warning This server is requesting that your username and password be sent in an insecure manner basic authentication without a secure connection administrator mr V Remember my password x J cn J 2010 Advanced Micro Peripherals Document version A 05 16 3 User Configuration HYDRA User Manual After completing the sign on the system will display the initial System Status screen in this example it is showing the 9 channel mode THE EMBEDDED VIDEO EXPERTS Advanced 2714 System Status The status of active channels is listed below Channel1 Video detected Channel 2 Video detected Channel 3 Video detected V Blind Video System Channel5 UM Video detected V Blind Video v v v v Version 111 106 Channel 6 Video detected V Blind Video v v v v Blind Video Blind Video Channel7 Video detected V Blind Video Channel9 Video detected V Blind Video Channel 10 video detected V Blind Video Channel 11
17. oxes indicate the activity for each channel Video detected means that a valid video signal has been detected and is being decoded and streamed Blind video means that the system has sensed that more than 90 of the screen area is the same color This can be useful to sense detect when a camera has been covered obscured NOTE Hydra 003 does not contain the Blind video detection 2010 Advanced Micro Peripherals Document version A 05 18 3 User Configuration HYDRA User Manual Encoding Options Peripherals THE EMBEDDED VIDEO EXPERTS Advanced Micro d Encoding Options This menu sets the streaming server to either 9 or 12 channel mode Please note that changes to this setting will only take effect after a server restart Please use the System Control page to commit the changes and restart the server Number of channels 12 channel Please note that changes to the standard will only take effect after a server restart Please use the System Control page to commit the changes and restart the server vo tnt PAL gt The tabs below can be used to change the encoding settings for each ofthe active channels The All tab provides a convenient way Version 111 106 of updating all channels in one step Any changes to these settings will take effect immediately To permanently save the configuration please use the System Control page to commit the changes and restart the server Ait cha ch2 ch3
18. ransient suppression however there is no internal fuse It is recommended that an external fuse 4A is used within the power supply cable loom to provide added protection Note The HYDRA uses a non isolated power supply The Ov GND input on the PWR connector is connected internally to the chassis case and is also the ground reference for the video input signals The Ethernet LAN connector uses a standard RJ45 connector This may be connected within an Amphenol MIL DTL 38999 compliant housing as specified in the Connector Description section Power Up Sequence After connecting the power video and optional audio and LAN inputs switch ON the unit using the front panel PWR ON OFF switch note this is a locking switch and must be pulled slightly in order to change position The LED should illuminate to indicate that the internal system is operational The system takes approximately 90 seconds to boot and enable access to the browser based HYDRA user interface At this point the HYDRA presents the Login screen to request a User Name and Password refer to User Configuration section for more details The HYDRA will begin streaming video automatically approximately 1 minute 45 seconds after power up 2010 Advanced Micro Peripherals Document version A 05 12 2 Installation HYDRA User Manual Connector Descriptions The HYDRA uses industry standard connectors as shown below PWR connector pin B is connecte
19. the file is valid and then automatically up grade and re start the system In the event that the file is not accepted the HYDRA will disregard the file and not re start no other warning is given 2010 Advanced Micro Peripherals Document version A 05 25 3 User Configuration HYDRA User Manual Note The upgrade process may take several minutes It is critical that the system is NOT powered down during this update process The system should remain on until the system has re booted and the System Status screen is accessible After this system re start the encoding configuration and system passwords will always be reset to the factory defaults In some cases the operating mode 9 12 channel amp PAL NTSC mode may also be reset Only the IP address will remain unchanged 2010 Advanced Micro Peripherals Document version A 05 26 3 Contacting AMP HYDRA User Manual A Contacting AMP Sales AMP s sales team is always available to assist you in choosing the board that best meets your requirements Contact your local sales office or hotline Sales office US Sales office UK Advanced Micro Peripherals Inc Advanced Micro Peripherals Ltd Suite 424 1 Harrier House Sedgeway Business Park 234 5 Ave Witchford Cambridge New York NY CB6 2HY USA 10001 United Kingdom Tel 1 212 951 7205 Tel 01353 659500 Fax 1 212 951 7206 Fax 01353 659600 E mail sales amp usa com E mail sales ampltd com Web www amp usa com Web
20. trusion rubber base plate and stainless steel fixings End plates sealed with rubber gasket Paint STANAG 2338 compliant Infrared Reflective 2010 Advanced Micro Peripherals Document version A 05 7 1 Introduction HYDRA User Manual Compliance specifications EMC Immunity EN61000 6 1 2007 Generic immunity tests for Information Technology Equipment including EN61000 4 3 RF field immunity EN61000 4 6 RF common mode immunity EN61000 4 4 Fast transient EN61000 4 2 ESD EMC Emissions EN55022 2006 Ai Class B Conducted radiated emission tests for Information Technology Equipment Vehicle Immunity 1S07637 2 2004 Electrical transient conduction on vehicle power lines Pulses 1 2a 2b 3a 3b and 4 Vibration MIL STD 810F Test method 514 Procedure I for General Vibration Category 20 Ground vehicles Thermal Shock MIL STD 810F Test method 503 Procedure I Enclosure sealing IP54 compliant against ingress of dust and water spray assuming supplied connector covers are used on un used video audio and Ethernet ports Full details of test reports and associated Declarations of Conformity are available on request Network compliance Real Time Protocol compliant with RFC 3550 as well as Real Time Streaming Protocol RTSP compliant with RFC 2326 2010 Advanced Micro Peripherals Document version A 05 8 1 Introduction HYDRA User Manual Ordering information The following part number s can
21. words do not match After changing the password use the Set password button to save the settings to the HYDRA unit and then the Commit button to permanently save the settings and re start the system IMPORTANT NOTE It is not possible to automatically recover or reset the password In the event that the password information is lost please contact Advanced Micro Peripherals support ampltd com 2010 Advanced Micro Peripherals Document version A 05 24 3 User Configuration HYDRA User Manual HYDRA Firmware Updates The HYDRA firmware may be updated using a remote access and updating procedure Access the Upload page using the following address this is not accessible from the HYDRA menus http 192 168 1 123 8080 upload ph Note The IP address may be different to the example shown Enter the login and password details as required to gain access to the HYDRA server Advanced Micro Peripherals THE EMBEDDED VIDEO EXPERTS Only official software upgrades from AMP should be used Please browse to the location of the update package and then click the upgrade button The system will upgrade the software and automatically reboot This process may take a few minutes Network Upgrade Version 111 106 Select the Browse button to locate the bin file on your host system and then select the Upgrade button The file will automatically upload and be saved to the internal storage The HYDRA will verify that

Download Pdf Manuals

image

Related Search

Related Contents

equIpment detaIlS    Total Energy Save System  Samsung CE271FN Manuel de l'utilisateur  Samsung PA9250S1 用戶手冊    School Enrolment  Aboserbedor de Energia BFD  10月号  manuel - Signel  

Copyright © All rights reserved.
Failed to retrieve file