Promis Quick Guide
Contents
1. Tags list and select Delete from the Edit gt Tags or pop up menu Deleting a Tag is also possible by dragging the tag to the Deleted Items location Deleted tags are transferred to the Deleted Items location To delete tags forever the tags must be deleted from the Deleted Items location as well You can move tags to other locations by dragging amp dropping Tags have certain properties To see the properties for a tag right click on the tag and click Properties Basic properties are displayed and explained as follows Page 7 of 12 Base Properties Base properties Acthiond properties Colector properties Tages emea en ee Tasna arcean Tag desvistin peered Tope Deca Terceaue sae f a Tager vaie pot Mimuriange Maxum ange fe Lowe tn Low tn Hah int Hiri iri Po o ia lia Tag code Usually the serial number by default Tag name Each tag has a name If multiple sensors are being used at the same time users can input a tag name to allow easy identification of the location of the sensor Tag ID The tag ID is automatically generated by Promis Parameter A tag must be associated to one of the defined parameters Type The type of tag can be one of the following Type Deseri Sample A measurement sample of a continues signal Counter A registration of a continuous increasing counter value E g a kWh
2. click Start as Application will a new window open Otherwise when you click Start as Service the data collector will run in the background and no window will open Once done a message will inform you that the connection is established and the software will start automatically to read all the devices that are communicating with the receiver and display them by their Serial Numbers on this window If the connection for some reason has failed check the connection between the receiver and the computer The above feature keeps track of the communication between the Promis and your receiver Any errors are also displayed in the box If you would like to you can make it run in the background so it will not be noticed Click X on the top right hand corner and click No to iconize this window At any time data collection can be halted by selecting Stop Promis Data Collector from the Control menu Monitoring and Features At this point the Promis is continuously collecting and storing data in its database To access devices that are being monitored on the main platform click Locations and select Tags from the bottom bar Page 5 of 12 fer 5 EEEE A eee Now in the main window you can see those devices in the example above a Relative Humidity Sensor and a Temperature Sensor are displayed Below different features of the software are introduced Additional instructions for defining
3. counter Pulse A registration of a non continuous signal E g an impact State Step A measurement sample of a discrete signal Number of Decimals Specify the number of relevant decimals to be displayed Target The target value set point for this tag Range Specify the Min and Max range for the tag Measurements outside this range will not be displayed The Y axis of the Player will be scaled to the specified range Limits If a measurement is outside its limits it will be displayed in red and if required an alarm can be passed to the Messenger for further dispatching On the top of this window there is another tab for Additional Properties There you can specify which options you would or would not like Promis to display Also there is a section for setting an alarm system for a tag For more information on alarming please refer to Scigiene s user manual for the Messenger Software Additional Properties Page 8 of 12 Under the Additional Properties tab users can configure where and for whom they want the information displayed either the map page recent page or the history page Users can also choose to have an alarm go off if values are beyond a certain range or when values are not recorded within a particular period of time Collector Properties aEF ATT DOAS TEVE To adjust the offset of the sensor if suggest on the Scigiene Certificate of Traceability and Calibration enter the val
4. locations and others can be accessed from the Main Manual at http www projex nl eng index htm PARAMETERS UNITS Parameters can be used to line up similar tags with a common name and a common unit Assume you have to measure a flow at several locations In this case you could define a parameter named flow with unit m3 h For each location you define a measurement tag for flow registration and you associated all these tags to the same parameter To edit parameters select Parameters Units from the Edit menu and the following window will pop up are Tr Desen j ET A Tawe srna se a Tr ae er mar x iF J o A parameter should have a unique code name and a unit Page 6 of 12 2 Parameter Unit properties Paares rane Patanet iD Praeter cde Uri foun reve Fr Pararete descipton TAGS You can define several tags per location If you require more information please see the Promis main manual mentioned in the previous section Taio Oe Nee P NE Ray To define a new tag select New tag from the Edit gt Tags menu or from the menu that pops up when you click the right mouse button To edit an existing tag select the tag from the Tags list and select Properties from the Edit gt Tags or pop up menu To delete an existing tag select the tag from the
5. their Tags Also upon selecting any tab from the bottom bar that action will be displayed here The bottom bar includes pr location Tags shows the list of tags associated to the selected location Map shows the geographical map CAD drawing or picture of the selected Recent shows the most recent values of the selected location Player plays back measurements in time Charts shows custom defined charts History shows measurements of the selected location in tabular form 3 4 5 6 Reports shows custom defined html reports 7 8 Comments shows custom defined comments In this manual only the Tags Recent Charts Reports and History tabs will be covered If you would like to learn more about these and other tags please refer to the main Promis User Manual available at http www projex nl eng index htm USERS Promis knows two types of users Administrators and View only users An Administrator is allowed to configure on a licensed system Promis and to view all locations View only users are only permitted to view granted locations The maximum number of users is dependent of your license The standard license includes the right to define 4 users To edit users select Users from the Edit menu and the following window will pop up anna Taian Fear nina doned edi cd Page 3 of 12 A user should have a
6. Page 1 of 12 1295 Morningside Avenue Unit 16 17 Toronto ON MIB 4Z4 Canada Phone 416 261 4865 Fax 416 261 7879 www scigiene com uick Guide Promis is an application to organize view and visualize measurement data For monitoring purposes for each device automatically or manually a tag can be defined Measurements will be registered to the tags for each device based on this Data can be printed saved and emailed in graphical jpg tabular xls and report html form Promi Operating Promi Once your Wireless Receiving system has been configured and set up to your computer Promis can be installed to collect store and retrieve data to use Install the software from the CD that has been provided to you In the auto run select start installation and follow the instructions When Promis has finished installation open the software by clicking on the Promis icon When you open Promis you are asked to login for the first time with an empty database You should login with the user name Administrator and leave the password field blank Charge Dla Soue The next window that opens up is the main platform of the software The vertical right hand side of this main window displays a list of the different locations that data acquisition is occurring Page 2 of 12 SPS Ts P ae EAI The second window to the right of the Locations window is where all the devices appear with
7. om the Edit gt Charts menu or from the menu that pops up when you right click the mouse button From the window that opens up with a list of tags select the ones that you would like to graph click Close In the new window name your chart edit it and click OK Now you can view the defined chart To edit an existing chart select the chart from the Charts list and select Properties from the Edit gt Charts or pop up menu To delete an existing chart select the chart from the Charts list and select Delete from the Edit gt Charts or pop up menu Chart can also be customized and modified from chart Properties see the Main Manual REPORTS The Report page is used to show defined reports Page 11 of 12 Devise T Dipl arate ent Man poe Pactagenen es Ohearen OO ge a ae a a Bramme sat Eam Ear Elati Epsemite ee Standard Report T Eon You can define several reports When creating a new report Promis generates a default report based on the tags that you select The default report displays a summary Count Min Max and Average over the selected period Reports can be printed or saved or e mailed as Html compatible documents For information on how these can be done please refer to the main User Manual for Promis mentioned in previous sections To define a new report select New report from the Edit gt Repo
8. rts menu or from the menu that pops up when you right click the mouse button Select tags that you would like to be reported on the new window and click Close A sample of the report style will be viewed You may name the report or edit the format Once done click OK To edit an existing report select the report from the Reports list and select Properties from the Edit gt Reports or pop up menu To delete an existing report select the report from the Reports list and select Delete from the Edit gt Reports or pop up menu HISTORY The history tab allows users to view the data collected by all sensors from a specific location It displays the time interval each reading was collected the number of readings collected the maximum and minimum readings and the average value of the readings If multiple sensors are being used at the same time the appropriate tag names to each sensor will allow for easy identification Page 12 of 12 Additional instructions can be accessed from the Main Manual at hittp www projex nV eng index htm 1295 Morningside Avenue Unit 16 17 Toronto ON MIB 4Z4 Canada Phone 416 261 4865 Fax 416 261 7879 veww scigione com
9. ue into the offset box The offset is an adjustment that can be made to your sensor if the readings during the certification process were off by a certain value By entering an offset value your sensor will now give a more accurate reading This can also be done by creating a conversion table as listed below Conversion Table Page 9 of 12 A Conversion Table can be created by the user allowing them to calibrate the sensor if readings are incorrect Go to Edit and select Conversion Tables Functions To add a new table click Add oor con Cero BUA The following window will appear Give a name to the new table Here you can manually input the values recorded by the sensor and the corresponding engineering values that you want the sensor to read instead When finished click ok After the new table has been added you can now select the appropriate conversion table listed under collector properties by right clicking on the sensor in the Tags tab and selecting the collector properties tab at the top RECENT Tab The Recent page shows the most recent values of the tags associated to the selected location in tabular form Page 10 of 12 This sheet can be printed or saved or e mailed as an Excel compatible sheet CHARTS The Chart page is used to show defined charts Ramon Et Goi eu EE a ee To define a new chart select New chart fr
10. unique Name which is always in capitals This is the Name used to login into Promis When creating a new user the password will be blank and the user has to change it at first login If a user forgets its password an administrator can reset the password Start Data Collect The first step to start the data monitoring is to activate the Data Collector From the menu bar click Control From the drop down menu under Control click Start amp Configure Promis Data Collector for SCIGIENE Wireless System Note If the information listed in this window is not accurate click to highlight the incorrect option From the buttons on the right select change to modify TCP IP Address or Serial Port to their correct values and click Ok to save these changes Should you not know what the configuration for your receiver is contact the provider Page 4 of 12 How do you want to stat the Promis Data Collector for SCIGIENE Witeless System Furs rable ard stats automaticaly ater a reboot Star an Appoaton Pune visible but docs no slat autorrateal aft a rsbool DoretStat From the new window select the proper Adapter and click Start Promis Data Collector at the bottom A message will appear asking you whether you really want to start this collector say Yes A Start Confirmation window will open asking Start as Service Start as Application or Do not start Only when you