1. 14 3 SCHEMATICS m E H M 15 P 15 3 2 COMMUNICATION 16 17 Rev 1 08 Copyright 2005 ZMD AG All rights reserved The material contained herein may not be reproduced adapted merged translated stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice 2 17 AS Interface Programmer User Manual 1 Hardware 1 1 Board description CMOS Interface ASI ASI ASI ASI Input 30V CMOS Interface Rev 1 08 Copyright 2005 ZMD AG T d S Je e Input 30V RS232 Interface int x 2 1 j Be i y e Mowossace c rr p vites T Y Pr m 2 T Sa NEL sli uC Interface LED 5 LED 1 4 Connection to the network The Programmer runs as AS i Master In AS i mode LED5 off the ASi Programmer be powered via the ASi network Otherwise the power supply of the connected ASi network can be provided by the ASi Programmer Therefore a DC power supply must be connected to the 30V input of the ASi Programmer In this case the ASI Programmer handle the data decoupling via the
2. A E 4 1 2 1 ASi BUS powered setup aussi issus sa seg use 4 1 2 2 Internal ASI power nnn nnn nna nnn nnns nnn nnns 5 1 2 3 Master control via CMOS Interface ccccccccssseecceeeseeeceeeeeesseceeeceeeseeeeeeaeeeseeeeseuaeeeeesaaeeeeeeeeas 5 OV 6 2 1 SETUP AND INSTALLATION asas aae eaae aea de 6 2 2 GUI GRAPHICAL USER INTERFACE 6 2 2 1 Automatic software nnne nnns nane rns 6 222 Main WINDOW x 7 2 2 3 Graphical Input Output 7 2 2 4 Change parameter 8 2 2 5 Change address P 10 2 2 6 EEPROM nennen nennen nnne nennen nnn nn nnn nnn nnn nnns nnn nnns 11 12 2 3 TELEGRAM EcnncPenil Te 13 2 3 1 Telegram structure of Standard AS i telegrams in Terminal Mode 13 2 3 2 Telegram structure of special functions in Terminal
3. to disable the firmware update for this session The update of a new firmware version is also possible via the menu Options Settings Firmware Update To upload a new file a actual hex file is required Rev 1 08 Copyright 2005 ZMD AG All rights reserved The material contained herein may not be reproduced adapted merged translated stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice AS Interface Programmer User Manual 2 2 2 Main window IMD A5 interface Programmer at COM 1 Seles File Tools Options Info ZMD AS Interface Programmer Version 1 04 Graphic Control Terminal Change Address Program EEPROM Functions Graphical Input Output Manual network slave Address EEPROM programming control control Management 2 2 3 Graphical Input Output Control This module allows to control an AS Interface network up to 62 slave modules bit by bit Graphical Input Output control runs in a loop mode for permanent data exchange with all slaves The data transfer rate between programmer and slave modules does not reachs ASi real time mode The speed of data exchange depends on the PC performance The minimum cycle time for data exchange with 1 slave is approximately 5 4ms Note Resulting of the slower ASi Programmer cycle time a communication error with connected modules may provoked if the ASi module Watchdog
4. and MCU Rev 1 08 Copyright 2005 ZMD AG LED LED LED E E MASA Lin E SS S S CMOS IF IC1 ATmega128L Miz mom eB xL ASI 12 5 058999 eat 66 6 a ti 4 m 10 10040 arcana Title Transceiver MCLI Sheet Mo 1 ZMD AG Grenzstrasse 28 D 01103 Dresden phone 449 351 8822 0 Www Project No A4990400 Revision No Date 16 02 04 Date 25 05 04 Author Gerd Hofmann phone ext 393 email ghofmanni zmd de File AS Programmer Rev2 08 06 04 All rights reserved The material contained herein may not be reproduced adapted merged translated stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice 15 17 AS Interface Programmer User Manual 3 2 PC Communication Interface Rev 1 08 Copyright 2005 ZMD AG B amp D ACT CONVERTER zi Nd PC Interface K5 T20L YAA Galvanic Isolated Interface Sheet No 2 ZMD AG Grenzstrasse 28 D 01109 Dresden phone 448 351 8822 0 Author Gerd Hofmann phone ext 393 email ghofmann zmd de zmd de File ASL Programmer Reve 08 06 04 Project Mo Revision Ma Date 18 02 04 Date 08 06 04 All rights reserved The material contained herein may not be reproduced adapted merged translated
5. 1 Programmer power on D3 telegram timeout D4 data flow at ASI CMOS LED 5 mode ASI CMOS off ASi channel active on CMOS channel active 1 2 Hardware setup To supply the system 2 setups are possible Do not mix both variants 1 2 1 ASi Bus powered setup Special ASi Power Supply Am o DENN 1 62 ASi Slave modules The power supply of the complete system including ASI modules and ASI programmer will be provided by a special AS interface power supply No additional power supply at the 30V connector is allowed Rev 1 08 Copyright 2005 ZMD AG All rights reserved The material contained herein may not be reproduced adapted merged translated stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice 4 17 AS Interface Programmer User Manual 1 2 2 Internal ASI power generation Laboratory DC Power Supply 32222287 24 MER d d gis 1c E lx see RS232 RC cem 4 H pr AE aes zx connection to PC 1 62 ASi Slave modules The power supply of the complete system including ASI modules and ASI programmer will be provided by a connected laboratory power supply No additional ASI power supply may be connected to the ASI network The data decoupling will be enforced by an data decoupling network integrated on the ASI Programmer T
6. AS Interface Programmer User Manual User Manual AS Interface Programmer Notice RESTRICTIONS THE ZMD AS INTERFACE PROGRAMMER HARDWARE AND ZMD AS INTERFACE PROGRAMMER SOFTWARE IS DESIGNED FOR IC EVALUATION LABORATORY SETUP AND MODULE DEVELOPMENT ONLY THE ZMD AS INTERFACE PROGRAMMER HARD AND SOFTWARE MUST NOT BE USED FOR MODULE PRODUCTION AND PRODUCTION TEST SETUPS ZMD AG SHALL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF DEFECTS RESULTING FROM I DELIVERED HARD AND SOFTWARE Il NON OBSERVANCE OF INSTRUCTIONS CONTAINED IN THIS MANUAL OR MISUSE ABUSE USE UNDER ABNORMAL CONDITIONS OR ALTERATION BY ANYONE OTHER THAN ZMD AG TO THE EXTENT PERMITTED BY LAW ZMD AG HEREBY EXPRESSLY DISCLAIMS AND USER EXPRESSLY WAIVES ANY AND ALL WARRANTIES WETHER EXPRESS IMPLIED OR STATUTORY INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTIUCULAR PURPOSE STATUTORY WARRANTY OF NON INFRINGEMENT AND ANY OTHER WARRANTY THAT MAY ARISE BY REASON OF USAGE OF TRADE CUSTOM OR COURSE OF DEALING Rev 1 08 Copyright 2005 ZMD AG All rights reserved The material contained herein may not be reproduced adapted merged translated stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice 1 17 AS Interface Programmer User Manual Table of Contents Page 1 HARDWARE 3
7. The bits can be changed by setting 1 a check mark in the corresponding box To send the parameter data to the slaves click on Write Parameter or transfer this configuration to the input output control window to set parameters by click at Write Parameter in the input output control window Parameter data will be read back and will be shown by red 0 and green 1 circles A bold boarder at an input bit shows the sent parameter data in the parameter window and in the corresponding input output control window With a click on Load Parameter File or Save Parameter File file the parameter settings can be saved or loaded Rev 1 08 Copyright 2005 ZMD AG All rights reserved The material contained herein may not be reproduced adapted merged translated stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice 8 17 AS Interface Programmer User Manual Parameter File 9 INPUT OUTPUT OUTPUT Normal 4 Slave Normal 4 Slave B Slave D03 D2 D1 OO le H I0 1 i z T E 3 LJ na LJ ca Load Parameter File i Save Parameter File File utility Enable Checkboxes Clear all Bits Scann Network Write Parameter M MEM DN M LESSE M M Sd E S EU Nee Du M D M su Dy M is bu M bu BE I Transfer to G
8. activation flag is set Handling 1 Click on Read Network Configuration to detect the connected Slaves 2 Click on Write Parameter for parameterisation of all detected slave modules To modify the parameter file click on Change Parameter File button Otherwise default parameters amp B0000 may used order to support the 4 In put 4 Output mode 4140 described in the AS I Complete Specification 3 0 this mode can be activated for all slaves in extended address mode separately The special nibble selected transfer protocol chapter 5 7 4 1 in Complete Specification To activate this feature in slave modules the corresponding EEPROM bit has to be programmed further 4 A Click on will start the loop mode for continuous data exchange non real time mode The loop counter shows the number of completed network data exchange cycles Rev 1 08 Copyright 2005 ZMD AG All rights reserved The material contained herein may not be reproduced adapted merged translated stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice 7 17 AS Interface Programmer User Manual 5 slave input data are shown by ed circles 0 and green circles 1 Output ports can be changed by setting a check mark in the corresponding field 6 All outputs will be erased by a click on Clea
9. allation System requirements 486 compatible PC 8MB RAM 12MB free HDD free COM port If the PC do not support a free COM port the ASI Programmer can be connected via a USB to serial adapter To use such a adapter a special driver delivered from USB to serial adapter manufacturer has to be installed Run Setup ZMD AS Interface Programmer Vxxx exe from your CD ROM Follow the instructions of the setup program Software updates are available via www zmd biz 2 2 GUI Graphical User Interface Start the graphical user interface by click at the ZMD AS Interface Programmer Icon in program menu or at desktop The software search for connected hardware automatically After a software update a firmware check of the microcontroller firmware will be enforced In certain cases a firmware update is necessary to use new software features 2 2 1 Automatic software update After program start the software check s the uC firmware To support new features a firmware update is recommended if an old firmware was detected Attention use new A5i Programmer Features a Firmware update is required Do you wank to upload a new Firmware Mein Abbrechen e Click on Yes to update a new firmware version to the uC The update process may not be interrupted During the update process do not switch to other PC tasks do not remove cables or power e Click on No to disable the automatically firmware update in future e Click on Cancel
10. apted merged translated stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice 13 17 TI U AS Interface Programmer User Manual 2 3 2 Telegram structure of special functions in Terminal Mode Description Remarks 00000 ox mb Lock AS Ichannel AS Locks the Programmer board to the AS I channel default LED5 off setting keeps alive after power down Terminates the loop command Lxxx Echomodeon ON The Programmer repeats received commands character by character or _ mode off 0 The Programmer will not repeat received commands default a STX amp H02 always initiates a new command line Read Wasi coniguaion WS Reads the Wats contguraton delay tme benson essing command and executing the command Writes the Waitstate configuration XXX in milliseconds 0 default value Rev 1 08 Copyright 2005 ZMD AG All rights reserved The material contained herein may not be reproduced adapted merged translated stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice 14 17 AS Interface Programmer User Manual 3 Schematics 3 1 ASi
11. d translated stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice AS Interface Programmer User Manual 227 Terminal The terminal tool allows the communication with an AS interface network or a single slave module command by command Command line input Send command from the command line 2 3 ZMD AS interface programmer terminal V 1 07 Terminal window un PEE amp S interface programmer terminal 91 07 2004 found ZMO AS interface programmer at COM Port Command Answer Anser Answer Answer Answer Answer Answer Answer Answer Answer Answer Answer Answer Answer Answer l nswer Answer Answer Answer JCamand TI Mm quy i 4 C Oo C 4 J Status i Status Status Status Status Status Status Status Status Status Status Status Status i Status Status Status Status Status Status P Pa DP P PO PS DP Pa DP Pu Tex Size E xit Clear Lag Clear terminal window Change text size Type a valid command in the command line For example d12 2 data exchange to slave with address 12 send data 2 decimal Click on send or press return The terminal window sho
12. d be connected to the network Bit configuration EEPROM show and modify EEPROM Configuration ASI SW PIE BIT 3 BIT 1 BIT O Address 0 Slave Address Bit 3 Ste Bit 2 Slave Address Bit 1 Code Extention 1 Address 2 ID Code Extention 1 Bit 3 ID Code Extention 1 Bit 2 ID Code Extention 1 Bit 1 ID Code Extention 1 Bit D m Code Address 8 iw ID Code Bit 3 10 Code Bit 2 iw ID Code Bit 1 10 Code Bit B Code EXER 2 Address 9 ID Code Extention 2 Bit 3 ID Code Extention 2 Bit 2 ID Code Extention 2 Bit 1 ID Code Extention 2 Bit 0 T Code Address 10 Configuration Bit 3 10 Configuration Bit 2 10 Configuration Bit 1 10 Configuration Bit O Address B Hesg PAW 32k Pw Enable Address Invert Data In Watchdog Active Program Disable FID Disable Read IC Configuration Write IC Configuration Change Address EXIT Bit configuration Read EEPROM Write EEPROM hexadecimal 1 Click on Read IC Configuration to read current EEPROM setting 2 change EEPROM setting click on the control boxes or select a hexadecimal bit configuration from the select bar 3 To write EEPROM configuration click on Write IC Configuration 4 After the writing process the programmer software reads the current EEPROM configuration back from the IC Rev 1 08 Copyright 2005 ZMD AG All rights reserved The material contained herein may not be reproduced adapted merge
13. ead configuration DAR Current Network Configuration 1 Sea Be 0 4 Slave B Slave Slave to address a Slave to address 1011121314 15 16 17 18 18 20 21 22 23 24 25 26 27 28 29 30 31 B ia Lu NM Scam Set Address 4 f B 9 New slave address New slave address Write address normal addressing extended addressing mode A B Slave mode A B slave 1 Select a slave to change address 2 Select a new slave address the select menus show only free network addresses witch makes double addressing impossible 3 Click on Set Address to change the address Note Switching between normal addressing mode and extended addressing mode is impossible in this menu To activate the extended address mode the corresponding EEPROM setting ID Code amp HOA has to be set with EEPROM configuration tool Changing between A and B slave through changing of the Bit3 of Extended ID Code 2 will be handled automatically Rev 1 08 Copyright 2005 ZMD AG All rights reserved The material contained herein may not be reproduced adapted merged translated stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice 10 17 AS Interface Programmer User Manual 2 2 6 EEPROM Configuration e To program EEPROM functions only 1 slave with address 0 shoul
14. he DC supply voltage may be 24 VDC and 33VDC The supply voltage according to AS Interface Complete Specification is 29 5 31 6V To prevent the AS I power generation circuit decoupling circuit against a current overload limit the input current at Input 30V connector to 150 1 2 3 Master control via CMOS Interface The following circuit diagram shows the connection of an external ASI master circuit Special Laboratory DC ASi Power Supply Power Supply RS 232 connection to PC Maximum digital voltage level at CMOS input and output port is limited to 5V DC Do not pull up the LED IRD pin to Uout Pull up resistors are integrated in the ASI Programmer cirquit R6 R7 no additional pull up resistors are required The A SI LED pin can be connected to the IN pin at the ASI Programmer and the A SI IRD pin can be connected directly to the OUT pin of the ASI programmer To activate the ASI Programmer CMOS interface type CMOS in the terminal The LED D5 light red To switch back in normal ASI mode type ASI in terminal Rev 1 08 Copyright 2005 ZMD AG All rights reserved The material contained herein may not be reproduced adapted merged translated stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice 5 17 AS Interface Programmer User Manual 2 Soflware 2 1 Setup and Inst
15. onboard decoupling network Attend there is only one power supply connected to the ASI Programmer a ASI power supply at the ASI Network or a DC Power Supply at the ASI Programmer see chapter 1 2 30V DC Input voltage to supply the AS i network and the programmer via the on board decoupling network An additional AS interface power supply at the AS i network is not required A supply voltage of 24V DC will be also enough for simply test setups To prevent the AS I power generation circuit decoupling circuit against a current overload limit the input current at Input 30V connector to 150 CMOS output for manchester coded signals for control a ASi IC in master mode See detailed description in chapter 1 2 3 All rights reserved The material contained herein may not be reproduced adapted merged translated stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice 3 17 LNE AS interface Programmer User Manual RS232 interface connection to PC 19200 Baud 8 bit no parity 1 stop bit Connect this port with the enclosed cable to a free serial COM port at your PC After program start the ASI Programmer search beginning from COM1 to COM16 for connected hardware Via menu Options the COM port 1 8 can also selected manually uC Interface for uC firmware update access by ZMD only LED1 4 status interface D
16. r Outputs 7 Click on Change Address will open the slave addressing window Detected Slave INPUT OUTPUT INPUT OUTPUT Normal amp Slave Normal amp Slave B Slave B Slave B 2 0 0302 01 0900 4140 2 0 03 02 01 Input Output Control Scann Network Activation of 4 140 m ode Write Parameter RUN spec 3 0 Change Address bold boarder parameter bit P1 is set to 1 loop counter nn v in s o p OOO0O0O0O0000000000000000 e80000e0 0 OOO0O000000000000000000e000069000 OOO0O0O0O0000000000000000 e80000e 0 0 OQOOOOOOOOOOO0O0O00O00O00O00O eO0000 0 90 ibn Ts bn s bn s t d a n b e a de a e n ge n n n n uw a n i nig Eg i n s n mi E T E E iun Tie un dn n e un e un n ua e ua e n e lm n uw Sn n n i n T n n n YA m n aU n OOOO0O0O0O0O00000000000000000000800 OOO0O000000000000000000000000 600 OQOOOOOOOOOOO0O0O0O0O0O0O00O00000000000 ibo Toe bo fin n un e un un Pe un n n o d T n a Fk E E d S SHU Uy EAM BEES B BR OOOOOOO0O0O0O0O0O0O0O0O0O0O0O00O0O00000000600 2 2 4 Change parameter data This module can change parameter data for each slave module bit by bit After a network scan parameter data can be set to the slave modules
17. ratic Control EXIT Transfer parameter settings to input output control CO L to Po oO Fm C3 Ir ee ll zx Pers ss Ps es es Pos abs s bes es s Pb zs Pos ues es es rs es bs rs i bes hes as hes es Ws o hie Drs i Ds Nb e hia do a s s cs s Mc s bo s de c Ms hie s hie nia hie bs hie No s s s c nig c s i s Ws bes o Drs o D s hie s M s s hie s he s Mz s eeoe eoeo20 eoe EEE eoe eeoe eeoo EEL eoes E KDE eoe eoe ev reer eoeo eoo OOOO JOO Ponne TERI OAS POO is in is is A a ea 2500 ee Se bb BOR DB DX zs Pubs Des Pubs Ds Parameter Parameter Data output to data input the slave from slave Rev 1 08 Copyright 2005 ZMD AG All rights reserved The material contained herein may not be reproduced adapted merged translated stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice 9 17 AS Interface Programmer User Manual 2 2 5 Change address Change Address Current slave configuration R
18. stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice 16 17 LNEC AS interface Programmer User Manual 4 Notes Rev 1 08 Copyright 2005 ZMD AG All rights reserved The material contained herein may not be reproduced adapted merged translated stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice 17 17
19. ws the sent command and the corresponding answer In case of an error a timeout or an error description will be send Clear Log will clear the terminal window The T key brings the last send command back to the command line input textbox For detailed commands and other control functions refer to the following command table Rev 1 08 Copyright 2005 ZMD AG All rights reserved The material contained herein may not be reproduced adapted merged translated stored or used without the prior written consent of the copyright owner The Information furnished in this publication is preliminary and subject to changes without notice 1247 TI AS Interface Programmer User Manual 2 3 Telegram structure 2 39 1 Telegram structure of Standard AS i telegrams in Terminal Mode a or b no separator wy per ow s required 9 v5 wm 9 1 ex m _ mew 4 oa my or x oa ws asas oa ws ems w 9 jme _ Ew tm _ Reno ne General remarks Every command structure must be closed with CR return HEX Code or ETX End of Text HEX Code 03 Terminal Mode For commands and extended addressing bytes lower case letters or capitals can be used Rev 1 08 Copyright 2005 ZMD AG All rights reserved The material contained herein may not be reproduced ad