Home

GOT1000 GT15V-75ROUT RGB Output Unit User`s Manual

image

Contents

1. GT15V 75ROUT Mounting screw set 2 screws 2 stickers Extend interface relay board Compliance with the EMC and Low Voltage Directives When incorporating the Mitsubishi GOT into other machinery or equipment and keeping compliance with the EMC and low voltage directives refer to EMC AND LOW VOLTAGE DIRECTIVE of GT15 User s Manual The CE logo is printed on the rating plate of the GOT indicating compliance with the EMC and low voltage directives A 7 1 Overview This User s Manual describes the GT15V 75ROUT RGB output unit referred to as the RGB output unit hereinafter When mounting RGB output unit with GT1585V STBA and GT1575V STBA collectively referred to as the GOT hereinafter the RGB output unit can external display screens on GOT GOT GT15V 75ROUT External display To use the RGB output unit make the Communication Settings For setting details refer to GOT1000 Series Connection Manual For details of system configuration refer to GOT1000 Series Connection Manual 2 Specifications 2 1 RGB output unit Item Specifications RGB output A method dot s Analog RGB SVGA 800x600 Number of RGB output 1 channel channels Dot clock 38 362 MHz Horizontal scanning 37 87 kHz frequency Vertical scanning 60 30 Hz frequency Horizontal synchronizing timimg Vertical synchronizing timimg Viden signal Video signal i s RGB Uu RGB 15 844ms a
2. 630 47 01 Fax 7 495 545 3419 Westgate Business Park Ballymount AKHNATON BULGARIA Sirius Trading amp Services st ROMANIA NPP URALELEKTRA RUSSIA IRL Dublin 24 4 Andrej Ljapchev Blvd Pb 21 Aleea Lacul Morii Nr 3 Sverdlova 11A Phone 353 0 1 4198800 BG 1756 Sofia RO 060841 Bucuresti Sector 6 RU 620027 Ekaterinburg Fax 353 0 1 4198890 Phone 359 0 2 817 6004 Phone 40 0 21 430 40 06 Phone 7 343 353 2745 MITSUBISHI ELECTRIC EUROPE B V ITALY Fax 359 0 2 97 44061 Fax 40 0 21 430 40 02 Fax 7 343 353 2461 tm INEA CR doa CROATIA Craft Con amp Engineering d 0 0 SERBIA ech Losinjska 4a Bulevar Svetog Cara Konstantina 80 86 GE eleng MI HR 10000 Zagreb SER 18106 Nis Deh Phone 385 0 1 36940 01 02 03 Phone 381 0 18 292 24 4 5 MIDDLE EAST REPRESENTATIVES Fax 39 039 6053 312 Fax 385 0 1 36 940 03 Fax 381 0 18 292 24 4 5 Ges Ga re ld EUROPE B V SPAIN AutoCont CS s r o CZECH REPUBLIC WE SR d o o SERBIA 24 Shenkar St Kiryat Arie Carretera de Rub 76 80 Technologick 374 6 Izletnicka 10 1L 49001 Petah Tigva A 7 708 00 Ostrava Pustkovec SER 113000 Smederevo E 08190 Sant Cugat del Vall s Barcelona Phone 972 0 3 922 18 24 Phone 902 131121 A 34 935653131 Phone 420 595 691 150 Phone 381 0 26 617 163 Fax 972 0 3 924 0761 Fax 420 595 691 199 Fax 381 0 26 617 163 Fax 34 935891579 REESEN ge Hz CZECH REPUBLIC AutoCont Cont S r o SLOVAKIA Wr aand a CZ 58001 Havli k
3. 0 44 83848 12 MELTRADE Ltd HUNGARY GTS TURKEY Fert utca 14 Dar laceze Cad No 43 KAT 2 HU 1107 Budapest TR 34384 Okmeydan Istanbul Phone 36 0 1 431 9726 Phone 90 0 212 320 1640 Fax 36 0 1 431 9727 Fax 90 0 212 320 1649 Beijer Electronics SIA LATVIA CSC Automation Ltd UKRAINE Vestienas iela 2 15 M Raskova St Fl 10 Office 1010 LV 1035 Riga UA 02002 Kiev Phone 371 0 784 2280 Phone 380 0 44 494 33 55 Fax 371 0 784 2281 Fax 380 0 44 494 33 66 Beijer Electronics UAB LITHUANIA 4 MITSUBISHI ELECTRIC Savanoriu Pr 187 LT 02300 Vilnius Phone 370 0 5 232 3101 Fax 370 0 5 232 2980 Mitsubishi Electric Europe B V FA European Business Group Gothaer Stra e 8 D 40880 Ratingen Germany FACTORY AUTOMATION Tel 49 0 2102 4860 Fax 49 0 2102 4861120 info mitsubishi automation com www mitsubishi automation com
4. 49 0 2102 486 0 Fax 43 0 2252 488 60 Fax 373 0 22 66 4280 Fax 7 7212 501150 Fax 49 0 2102 486 1120 TEHNIKON BELARUS Koning amp Hartman b v NETHERLANDS CONSYS RUSSIA MITSUBISHI ELECTRICEUROPEB V CZECH REPUBLIC Oktyabrskaya 16 5 Off 703 711 Haarlerbergweg 21 23 Promyshlennaya st 42 Czech Branch BY 220030 Minsk NL 1101 CH Amsterdam RU 198099 St Petersburg Radlick 714 113a Phone 375 0 17 210 46 26 Phone 31 0 20 587 76 00 Phone 7 812 325 36 53 7 158 00 Praha 5 Fax 375 0 17 210 46 26 Fax 31 0 20 587 76 05 Fax 7 812 3253653 Phone 420 0 251 551 470 Koning amp Hartman b v BELGIUM Beijer Electronics AS NORWAY ELECTROTECHNICAL SYSTEMS RUSSIA Fax 420 0 251 551 471 Woluwelaan 31 Postboks 487 Derbenevskaya st 114 Office 69 MITSUBISHI ELECTRIC EUROPE B V FRANCE BE 1800 Vilvoorde N0 3002 Drammen RU 115114 Moscow French Branch Phone 32 0 2 257 0240 Phone 47 0 32 2430 00 Phone 7 495 744 55 54 25 Boulevard des Bouvets Fax 32 0 2 2570249 Fax 47 0 32 8485 77 Fax 7 495 74455 54 E Kee S INEA BH d o o BOSNIA AND HERZEGOVINA MPL Technology Sp z0 0 POLAND ELEKTROSTILY RUSSIA ie Aleja Lipa 56 UL Krakowska 50 Rubzowskaja nab 4 3 No 8 Fax 33 0 1 55 68 57 57 BA 71000 Sarajevo PL 32 083 Balice RU 105082 Moscow MITSUBISHI ELECTRIC EUROPEB V IRELAND Phone 387 0 33 921 164 Phone 48 0 12 630 47 00 Phone 7 495 545 3419 Irish Branch Fax 387 0 33 524 539 Fax 48 0 12
5. MOUNTING PRECAUTIONS e Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit onto from the GOT Not doing so can cause the unit to fail or malfunction Use this unit in the environment that satisfies the general specifications described in User s Manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration Tighten the mounting screws within the specified torque range Undertightening can cause the GOT to drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to the damage of the screws or the GOT e Do not touch the conductive and electronic parts of the unit directly Doing so can cause a unit malfunction or failure A 2 WIRING PRECAUTIONS Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions N CAUTION Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT Not doing so can cause a fire failure or malfunction Make sure to securely connect the cable to the connector of unit Incorrect connection may cause malfunctions Do not hold the cable by hand and pull it out from the unit When removing the cable from the unit make sure to hold the connector by hand and pull it Failure to do so may cause ma
6. v Brod SK 02601 Dolny Kubin AFRICAN REPRESENTATIVE Phone 420 0 569 777 777 Phone 421 0 43 5868210 UK Hatfield Herts AL10 8XB Fax 420 0 569 777 778 Fax 421 0 43 5868210 CBI Ltd SOUTH AFRICA Phone 44 0 1707 27 61 00 Private Bag 2016 Fax 44 0 1707 27 86 95 Beijer Electronics A S DENMARK CS MTrade Slovensko s r o SLOVAKIA 7A 1600 isand Lykkeg rdsvej 17 1 Vajanskeho 58 sando MITSUBISHI ELECTRIC CORPORATION JAPAN 5 4000 Roskilde K 92101 Piestany Phone 27 0 11 928 2000 Office Tower 2 HI Phone 45 0 46 75 76 66 Phone 421 0 33 7742760 Fax 27 0 11 392 2354 8 12 1 chome Harumi Chuo Ku Fax 45 0 46 75 56 26 Fax 421 0 33 7735 144 Tokyo 104 6212 gt Phone 81 3 622 160 60 Beijer Electronics Eesti OU ESTONIA INEA doa SLOVENIA Fax 81 3 622 16075 a E i stegne 11 S allinn l 1000 Ljubljana conte Ware ik Inc USA Phone 372 0 6 51 81 40 Phone 386 0 1 513 8100 vara kile iL Gane Fax 372 0 6 518149 Fax 386 0 1 513 8170 Phone 1 847 478 2100 Beijer Electronics OY FINLAND Beiler Electronics AB SWEDEN Fax 1 847 478 22 53 Jaakonkatu 2 Box 426 FIN 01620 Vantaa SE 20124 Malm Phone 358 0 207 463 500 Phone 46 0 40 35 86 00 Fax 358 0 207 463 501 Fax 46 0 40 35 86 02 UTECO A B EE GREECE Engis AG SWITZERLAND 5 Mavrogenous Str Hinterdorfstr 12 GR 18542 Piraeus CH 8309 Niirensdorf Phone 30 211 1206 900 Phone 41 0 44 83848 11 Fax 30 211 1206 999 Fax 41
7. A MITSUBISHI ELECTRIC GOT 1000 RGB Output Unit User s Manual GT15V 75ROUT Art no 01072007 aa MITSUBISHI ELECTRIC INDUSTRIAL AUTOMATION Version C SAFETY PRECAUTIONSe Always read these precautions before using this eguipment Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause hazardous D DANGER conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous A CAUTION conditions resulting in medium or slight personal injury or physical damage bei Sa a 10 Le e e e e rn Note that the A caution level may lead to a serious accident according to the circumstances Always follow the instructions of both levels because they are important to personal safety Please save this manual to make it accessible when required and always forward it to the end user A 1 DESIGN PRECAUTIONS N CAUTION e Do not bundle the control and communication cables with main circuit power or other wiring Run the above cables separately from such wiring and keep them a minimum of 100mm 3 94in apart Not doing so noise can cause a malfunction
8. ber Revision Mar 2006 IB NA 0800349 A First edition Feb 2007 IB NA 0800349 B Partial addition Chapter 1 Addition Compliance with the EMC and Low Voltage Directives IB NA 0800349 C Bartjal correcitions Compliance with the EMC and Low Voltage Directives Chapter 2 3 4 This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual 2006 MITSUBISHI ELECTRIC CORPORATION A 5 CONTENTS 1 Overview 2 Specifications 2 1 RGB output unit 2 2 Specifications of the cables 9 core combined cables used when connecting the external display 3 Part Names and External Dimensions 4 Installation Procedure ege aakhh een Laad 6 A 6 Manuals The following shows manuals relevant to this product Detailed Manual B ss name Manual number Model code GT15 User s Manual SH 080528ENG Sold separately 1D7M23 GOT1000 Connection Manual SH 080532ENG Sold separately 1D7M26 Relevant Manuals For relevant manuals refer to the PDF manual stored within the drawing software used Packing List The following items are included Product Quantity RGB output unit
9. lfunctions or damage to the unit or cable A 3 STARTUP MAINTENANCE PRECAUTIONS When power is on do not touch the terminals Doing so can cause an electric shock or malfunction Before starting cleaning always shut off GOT power externally in all phases Not doing so can cause a unit failure or malfunction Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit e Do not disassemble or modify the unit Doing so can cause a failure malfunction injury or fire e Do not drop the module or subject it to strong shock A module damage may result Before touching the unit always touch grounded metal etc to discharge static electricity from human body etc Not doing so can cause the unit to fail or malfunction DISPOSAL PRECAUTIONS N CAUTION When disposing of the product handle it as industrial waste TRANSPORTATION PRECAUTIONS N CAUTION Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of GT15 User s manual as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation A 4 REVISIONS The manual number is noted at the lower right of the top cover Print Date Manual Num
10. n the GOT case Remove the connector cover 5 Fasten the RGB output unit by tightening its mounting screws 4 places with tightening torgue 0 36 to 0 48 Nem 6 Fasten the bus connection unit by tightening the board fixing screws 2 places with the tightening torque of 0 36 to 0 48 Nem 5 7 When installing an extension unit on the unit that has been installed remove the connector cover and the sticker When not installing an extension unit on the unit that has been installed in order to avoid receiving electrostatic stick accessory stickers to cover the top of mounting screws 4 places Keep the connector cover fixed Keep the sticker stuck as itis Connector cover Accessory sticker Accessory sticker Point Remove the screws that fixes the extend interface relay board before removing the unit Above 6 A MITSUBISHI ELECTRIC HEADCUARTERS EUROPEAN REPRESENTATIVES EUROPEAN REPRESENTATIVES EURASIAN REPRESENTATIVES MITSUBISHI ELECTRIC EUROPE B V EUROPE GEVA AUSTRIA INTEHSISsrl MOLDOVA Kazpromautomaticslid KAZAKHSTAN German Branch Wiener StraBe 89 bld Traian 23 1 Mustafina Str 7 2 Gothaer Stra e 8 AT 2500 Baden MD 2060 Kishinev KAZ 470046 Karaganda D 40880 Ratingen Phone 43 0 2252 85 55 20 Phone 373 0 22 66 4242 Phone 7 7212 50 1150 Phone
11. nalog FH analog 0 7Vp p 0 7Vp p Timing chart HSYNC VSYNC Horizontal Vertical sync sync width 2 190 us width gt 0 607ms 3 206 s Horizontal sync 0 106ms Vertical sync 26 406 u s 16 583ms RGB external connection D Sub15 pin method Applicable wire size 9 core combined cable recommended Maximum cable length 30 m 98 4 feet Internal current consumption 5VDC 0 11 A Weight 0 16 kg 0 32 Ib 2 2 Specifications of the cables 9 core combined cables used when connecting the external display 1 Cable specifications Applicable cable Eguivalent to SP23 23352A UL20276 SB Applicable wire size 9 core combined cable recommended 2 Connection diagram GOT side 750 coaxical CRT side FA Si X mi rm H t gt 1 R 1 It i 6 RGND ii H 2 G AE 7 GGND i 73 B rt a s BGND he oR 5 GND 10 GND i m i 7 13 HSYNC eme r 14 vsvnc t 4 GND 1 9 NG d Twisted pair 11 GND ii 12 SDA LG 15 SCL b X D EE 3 Connector GOT connector Use the connector matching the following model for the GOT 15 pin D sub male inch screw type Manufactured by DDK 17HE R13150 73MC2 Connector a
12. t the display Use the connector applicable to the display 3 Part Names and External Dimensions 1 Part names and external dimensions of the RGB output unit 6 GOT main unit 3 133 5 24 3 0 12 PAL 1 TT lt 7 C N aa i s 4 M Dimensions of X when the RGB output unit is mounted to the GOT 12 1 18 0 71 10 4 21 0 83 Unit mm inch 105 4 13 98 3 86 Description Connector for RGB output Connector for connecting a 9 core combined cable Interface connector Connector mounted to the GOT Extension connector Connector to which a back extension unit is installed Connector for video RGB Connector connecting with the video RGB interface of connection GOT Board fixing screw Screw for fixing the extend interface relay board Mounting screw Mounting screws for fixing the unit to the GOT Rating plate 2 Extend interface relay board 27 5 1 08 Unit mm inch 4 Installation Procedure 1 Power off the GOT 2 Remove two extension unit covers of the GOT 3 Attach the extend interface relay board to the extend UE 2 side on the GOT After the installation detach the connector cover from the extend interface relay board 4 Fitthe RGB output unit i

Download Pdf Manuals

image

Related Search

Related Contents

VDM Digital Recorder User Manual    Bedienungsanleitung  RT 1003DA_deck.indd  Die cut title page.qxd  Cherry OPTICAL POWER WHEEL MOUSE    改善箇所説明図(PDF1,724KB)  Massive Wall light 34145/11/10  K96 User Manual - Rohde & Schwarz  

Copyright © All rights reserved.
Failed to retrieve file