1. Configure Internet Protocol Settings Configure Internet Protocol IP settings such as the IP address in one of these ways e Use the default IP address of the 1783 NATR 169 254 1 1 for the Public port or 192 168 1 1 for the Private ports by connecting the 1783 NATR directly to a computer To establish communication between a computer and the default IP address of the 1783 NATR enter a unique IP address in the local area connection properties for your computer The IP address of the computer must be on the same subnet as the default IP address of the 1783 NATR such as 169 254 1 2 for the Public port or 192 168 1 2 for the Private ports At least one of the Private ports must be connected with an assigned IP address to another device before the Public port will communicate For this reason it is suggested that you use the Private ports for initial configuration IMPORTANT e Use IP settings that are configured in RSLinx Classic communication software or Studio 5000 Logix Designer programming software Acquire IP settings from a DHCP server Use the DIP switches on the 1783 NATR to choose the configuration method to use for IP settings Refer to Set the DIP Switches on page 5 Use the DHCP Server If your network infrastructure does not provide DHCP BOOT functionality you can download our DHCP BOOTP server software to a personal computer that uses a Microsoft Windows operating system You can use this computer as the DHCP
2. 25 70 C 13 158 F The equipment must not be used outside of this range gt ATTENTION Use only a soft dry anti static cloth to wipe down equipment Do not use any cleaning agents gt Electrical Safety Considerations ATTENTION To comply with the CE Low Voltage Directive LVD all connections to this equipment must be powered from a source compliant with the following e Safety Extra Low Voltage SELV Supply e Protected Extra Low Voltage PELV Supply To comply with UL CUL requirements this equipment must be powered from a source compliant with the following e IEC 60950 1 Ed 2 1 Clause 2 5 LIMITED POWER SOURCES e EC 61010 2 201 Ed 1 Clause 9 4 Limited energy Circuits All wiring must comply with applicable electrical installation requirements e g N E C article 501 4 b gt North American Hazardous Location Approval The following information applies when operating this equipment in hazardous locations Products marked CLI DIV 2 GP A B C D are suitable for use in Class Division 2 Groups A B C D Hazardous Locations and nonhazardous locations only Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code When combining products within a system the most adverse temperature code lowest T number may be used to help determine the overall temperature code of the system Combinations of equipment in your system are subje
3. 3 Linear and Star Network Considerations When using the 1783 NATR ina linear or star network be sure that Ring Supervisor mode is not enabled By default the 1783 NATR is configured to be a non supervisor ring node IMPORTANT DIP switch 3 is used to make the 1783 NATR a ring supervisor in a DLR network To avoid adversely impacting communication in a linear or star network take these precautions e Make sure switch 3 remains in the Off position If switch 3 is in the On position the 1783 NATR will be automatically enabled as a ring supervisor e Make sure the Ring Supervisor mode is not enabled in RSLinx Classic communication software or Studio 5000 Logix Designer programming software When switch 3 is in the Off position the programming software controls whether the 1783 NATR is a ring supervisor Device level Ring DLR Network Considerations When using the 1783 NATR in a DLR network consider whether the 1783 NATR will be a ring supervisor By default the 1783 NATR is configured to be a non supervisor ring node Use one of these methods for controlling supervisor functionality e Use RSLinx Classic communication software or Studio 5000 Logix Designer programming software to set the Ring Supervisor mode and other supervisor related parameters This is the default method If you choose this option follow the procedures outlined in the online help that accompanies the software to enable Ring Supervisor mode e Use the DIP s
4. indicators 6 Ports for connection to linear or ring network 12 SD card slot A Port 1 B Port 2 By default the individual ports on the 1783 NATR auto negotiate link speeds 10 Mbps or 100 Mbps and duplex setting full or half IMPORTANT Configure the Ethernet port on the device you connect to a 1783 NATR so that it matches the speed and duplex settings of the 1783 NATR Failure to make the speed and duplex settings of directly connected devices match can result in higher error rates or loss of network connectivity Software Requirements You must have these versions of software Software Version RSLinx Classic 2 7 or later Studio 5000 Logix Designer Most current version Install the SD Card WARNING When you insert or remove the SD memory Card while power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding A 1 Remove the SD card from its original packaging if necessary 2 Verify that the SD card is locked or unlocked according to your preference Consider the following when deciding to lock the card before installation If the card is unlocked the controller can write data to it or read data from it Locked IIe e Unlocked Ww Locate the SD card slot on the rear of the 1783 NATR device SD Card Slot 4 Insert the SD card into the SD card slot You can ins
5. may contain more information regarding specific enclosure type ratings that are required to comply with certain product safety certifications In addition to this publication see the following e Industrial Automation Wiring and Grounding Guidelines publication 1770 4 1 for more installation requirements e NEMA 250 and EN IEC 60529 as applicable for explanations of the degrees of protection provided by enclosures gt IMPORTANT Any illustrations charts sample program and layout examples shown in this publication are intended solely for the purposes of example Since there are many variables and requirements associated with any particular installation Rockwell Automation does not assume responsibility or liability for actual use based upon examples shown in this publication Prevent Electrostatic Discharge ATTENTION This equipment is sensitive to electrostatic discharge which can cause internal damage and affect normal operation Follow these guidelines when you handle this equipment e Touch a grounded object to discharge potential static e Wear an approved grounding wriststrap e Do not touch connectors or pins on component boards e Do not touch circuit components inside the equipment e Use a static safe workstation if available Store the equipment in appropriate static safe packaging when not in use gt Rockwell Automation Publication 1783 PC017A EN P March 2015 Configurable NAT Router
6. of a screwdriver to open the latch so that you can remove the 1783 NATR from the DIN rail The bottom figure shows the latch at the bottom of the 1783 NATR in the open position E Ta Panel Mounting To panel mount a 1783 NATR by using these steps 1 Use the 1783 NATR as a template and mark pilot holes on your panel 2 Drill the pilot holes for M4 or 8 screws Wire the NAT Device WARNING When you connect or disconnect the Removable Terminal Block RTB with field side power applied an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding gt ATTENTION To comply with UL CUL requirements this equipment must be powered from a source compliant with the following e IEC 60950 1 Ed 2 1 Clause 2 5 LIMITED POWER SOURCES e IEC 61010 2 201 Ed 1 Clause 9 4 Limited energy Circuits All wiring must comply with applicable electrical installation requirements e g N E C article 501 4 b gt Provide DC power to the 1783 NATR by using the DC connector at the bottom of the 1783 NATR 1783 NATR Terminals Item Description 1 1783 NATR bottom 2 DC OV DC terminal 3 DC 24V DC nom terminal Connect the R
7. server To set the network address of the Private ports by using the Rockwell Automation DHCP BOOTP server follow these steps Access the DHCP BOOTP utility at http www ab com networks ethernet bootp html Download the version 2 3 2 DHCP BOOTP utility Extract the zipped files to a temporary directory Inthe temporary directory double click setup exe to install the DHCP BOOTP utility Run the utility See the following chart which describes what happens next depending on whether DHCP is enabled on the 1783 NATR Nm A UWV N 1 The DHCP server is supported on only the Private port Configurable NAT Router 5 DHCP Status Result Enabled 1783 NATR asks for the IP address of the Private ports from a DHCP BOOTP server Consult the online help available in the BOOTP DHCP application to configure the server to provide the desired IP address for your 1783 NATR Not enabled 1783 NATR uses the IP settings that are stored in nonvolatile memory The default IP address that is stored in memory for the Private ports is 192 168 1 1 Set the DIP Switches Use the DIP switches on the 1783 NATR to do the following e Specify the method for configuring Internet Protocol IP settings for the Private ports such as the IP address Enable the Ring Supervisor mode with its current parameters Restore the factory default settings See the following figure to understand DIP switch On and Off positions Switch 1 Switch 2 Switch
8. through the links under the Diagnostics folder Allen Bradley see NEWS Expand Minimize D tome G Diagnostics System Resource Utilization d Network Settings Ethernet Statistics Ring Statistics Address Conflict Detection E Diagnostic Overview CPU Utilization network Settings D Ethernet Statistics P Ring statistics E Address Conflict Detection CA configuration Ee DIP Switches 3 2 1 mom Memory Used 128MB max 4657968 Network Status Normal Module Uptime 02h 24m 20s Ring Supervisor 0 0 0 0 00 00 00 00 00 00 Network Address Translation Statistics Translation Enabled Enabled Rules o Packets Translated in O out O Added Mappings o Expired Mappings o Seconds Between Refresh is Disable Refresh with 0 Rockwell Automation Publication 1783 PC017A EN P March 2015 Configurable NAT Router 7 1783 NATR Status Indicators y Indicator Description oo BR Ri E AN CC Indicator Status Description OK Off Module does not have 24V DC power Green Module is operating correctly Flashing red Recoverable fault or duplicate IP address has been detected Red An unrecoverable fault has been detected Flashing red green Module is performing a power up self test LINK1 LINK2 Off No data is being transmitted Green Private port link that is established at 100 Mbps Module is ready to communicate Flashing green Data transmission in progress at 100 Mbps Yellow Pr
9. 0 e The type of protection is Ex nA IIC T4 Gc according to IEC 60079 15 e Such modules comply to Standards IEC 60079 0 2011 IEC 60079 15 2010 reference IECEx certificate number IECEXUL15 0026X Environment and Enclosure WARNING Do not replace components or disconnect equipment unless power has been switched off or the area is known to be free of ignitable concentrations This product must be installed in a suitable weatherproof metal enclosure gt ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category Il applications as defined in IEC 60664 1 at altitudes up to 2000 m 6562 ft without derating This equipment is not intended for use in residential environments and may not provide adequate protection to radio communication services in such environments This equipment is supplied as open type equipment for indoor use It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts The enclosure must have suitable flame retardant properties to prevent or minimize the spread of flame complying with a flame spread rating of 5VA or be approved for the application if nonmetallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this publication
10. 0 00 bc 61 1e cb Advanced Network Private IP Address 192 168 1 1 Device Services Product Revision 1 001 Build 26 Firmware Version Date Oct 7 2014 15 10 44 Serial Number A0030499 Status Awaiting Connection Uptime 02h 23m 00s Copyright 2014 Rockwell Automation Inc All Rights Reserved 21 At the device reset warning dialog box click Reset Module 22 Wait until the module reboots 23 Under Device Configuration click Save to SD The Successful SD configuration save window appears 24 At the Successful SD configuration save window click OK Add Addresses to the Routing Table Use the Network Address Translation tab in the web user interface to add addresses to the routing table Navigate to the Network Address Translation table and perform the following 1 Verify that NAT Enable is set to Enabled and click New Network Address Translation Adva Network Address Translation NAT Enable Enabled v Network Address Translation Rules Enabled Public IP Network Showing 0 rules New Range 2 At the Create New Rule dialog box enter your own IP addresses and description to configure the individual translations Create New Rule x Public IP Address 169 254 1 2 x Private IP Address 192 168 1 1 Description Enabled iv Add Rule Cancel 3 Click Add Rule after entering all information Access Diagnostics The 1783 NATR device diagnostics are accessed through the web user interface by navigating
11. 0 Cyberport Road Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Publication 1783 PC017A EN P March 2015 PN 298965 Copyright 2015 Rockwell Automation Inc All rights reserved Printed in the U S A
12. 2 Ho According to actual situation extra explanations can be given here for the technical reasons of items with X EEIE GB T 26572 SENS St GB T 26572 de Rockwell Automation Publication 1783 PC017A EN P March 2015 Specifications Attribute 1783 NATR Power consumption max 3W DC power supply input 20 4 27 6V DC limited voltage Ethernet connections e RJ45 connector according to IEC 60603 7 2 or 4 pair e Category 5e minimum cable according to TIA 568 B 1 e Category 5 cable according to ISO IEC 24702 Wire size Single wire 0 33 3 3 mm 22 12 AWG stranded copper wire rated at 75 C 167 F or greater 1 2 mm 3 64 in insulation max Double wire 0 33 1 3 mm 22 16 AWG solid copper wire rated at 75 C 167 F or greater 1 2 mm 3 64 in insulation max Torque 0 6 0 8 Nem 5 7 Ibein on power connector Temperature operating 25 70 C 13 158 F IEC 60068 2 1 Test Ad Operating Cold IEC 60068 2 2 Test Bd Operating Dry Heat IEC 60068 2 14 Test Nb Operating Thermal Shock Temperature surrounding air max 70 C 158 F Temperature code T4 Current rating 150 mA For More Information These documents contain additional information concerning related products from Rockwell Automation Resource Description Stratix Ethernet Switches Specifications publication 1783 TD001 Contains technical specifications environmental specifications certifications and other information that per
13. 3 Use this procedure to set the DIP switches 1 Move the switches to the desired position and cycle power to the 1783 NATR IMPORTANT The switch settings take effect only at powerup Switch changes do not modify the behavior of the 1783 NATR until the 1783 NATR is power cycled Powerup Behavior Switch Switeh2 Switch 3 Internet Use DHCP for Private port IP address by default Off factory Off factory The position of Protocol changeable by software default default switch 3 does settings The Public port configured by software not affect IP Factory default settings for the Public port are settings 169 254 1 1 subnet mask 255 255 255 0 Gateway 0 0 0 0 Uses the IP settings configured by software Factory default settings for Public port are 169 254 1 1 subnet mask 255 255 255 0 Gateway 0 0 0 0 Factory default setting for the Private ports is IP address 192 168 1 1 subnet mask 255 255 255 0 Gateway 0 0 0 0 Loads module configuration from SD card suspends operation Ring Enables Ring Supervisormode Enables Ring Supervisormode Supervisor mode The positions of switches 1 On Supervisor and 2 do not affect Ring mode Lets Ring Supervisor mode to be enabled via Supervisor mode Off factory software default Restores the factory default settings and then suspends On or Off operation 2 Observe these guidelines for use of the DIP switches e Out of the box all three switches are in the Off positi
14. EEN oe S EEN CUPRA TARE ACNE PI HR EAEE 1 AU A IRE A ET DA aa A REAR o Di HR ARS wd H AE a PE HE Ae EY A ee PT BE EY Ce BE SZ o POZOR Nez za nete instalovat konfigurovat i provozovat tento v robek nebo prov d t jeho dr bu p e t te si tento dokument a dokumenty uveden v sti Dodate n zdroje ohledn instalace konfigurace a provozu tohoto za zen U ivatel se musej vedle po adavk v ech relevantn ch vyhl ek z kon a norem nutn sezn mit tak s pokyny pro instalaci a elektrick zapojen WN HATS AR ALARTE 1335 D innosti zahrnuj c instalaci nastaven uveden do provozu u v n mont demont a dr bu mus vykon vat vhodn proskoleny personal v souladu s p slu n mi provad cimi p edpisy Pokud se toto za zen pou v zp sobem neodpov daj c m specifikaci v robce m e b t naru ena ochrana kterou toto za zen poskytuje UWAGA Przed instalacj konfiguracj u ytkowaniem lub konserwacj tego produktu nale y przeczyta niniejszy dokument oraz wszystkie dokumenty wymienione w sekcji Dodatkowe r d a omawiaj ce instalacj konfiguracj i procedury u ytkowania tego urz dzenia U ytkownicy maj obowi zek zapozna si z instrukcjami dotycz cymi instalacji oraz oprzewodowania jak r wnie z obowi zuj cymi kodeksami prawem i normami Dzia ania obejmuj ce instalacj regulacj przekazanie do u ytkowania u ytkowanie mo
15. J45 Ports A WARNING If you connect or disconnect the communications cable with power applied to this module or any device on the network an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding Follow these steps to connect the copper Ethernet ports on the 1783 NATR 1 Locate the copper Ethernet RJ45 ports on the front and bottom of the 1783 NATR as shown in the figure 1783 NATR Item Description 1 Public port on 1783 NATR device front panel 2 Ports on 1783 NATR device bottom for connection to the linear or ring network 2 Connect one end of an Ethernet cable to the front panel port used as a device port 3 Connect the other end of the Ethernet cable to the device in your network 4 Connect one end of a second Ethernet cable to a port at the bottom of the 1783 NATR 5 Connect the other end of the Ethernet cable to the linear or ring network 6 If your network uses the other port at the bottom of the 1783 NATR repeat this process for the other port When configuring a DLR refer to Device level Ring DLR Network Considerations on page 3 to avoid adversely impacting your network IMPORTANT Rockwell Automation Publication 1783 PC017A EN P March 2015 Download the EDS File To use RSLinx Classic communication software to configure the 1783 NATR follow these steps to download
16. OKDADKG COeAMHEHMII a TAKKE C Tpe6OBAHNAMN BCEX DDUMGHHMES HOPM 3aKOHOB N CTAHAApTOB Bce neucrpug BKNIOYaA ycTaHOBKY HanaA KY BBO B KCNNYATALMIO NCNONb30BAHNE c6opky pa36opky H TEXHNYECKOE o6cnykuBaHue AONXHbI BbINOJHATBCA o6y4eHHbIM NePCcOHaJIOM B COOTBETCTBUN C NPAMeHUMbIMM HODMAMM N npaBulaMn Ec o6opyAoBaHve Ucnonb3yeTcA He NpeAYCMOTPeHHbIM Npon3BogNTenem 06pa30M 3aLynTa OGopyAOBaHuA MOXKET Dt HapylieHa TER i EC ER REE CIMT TORIC ABR LOR RR ORIR REL PRIFICOV COB S REO KY ARRS VCS BIC A IL T LEi dE FRCORAT SRI EE BRO BAFICIIA TT RIK LE OMRO SIRI BAL CWS DER SO ET EWE WERSOBAA BEA MT HE RST ee DRA VESIL THU TC alli 2 Se UT Te RFRA DST ST OVER SOE Re DS Bie S TC EO FRE SAV CWE CHA SCO SBE ze LY ESI CW SRD TRRDNOANAHSDVET ACHTUNG Lesen Sie dieses Dokument und die im Abschnitt Literaturverweise genannten Dokumente zur Installation Konfiguration und Bedienung dieser Ausr stung sorgf ltig durch bevor Sie dieses Produkt installieren konfigurieren bedienen oder instandsetzen Benutzer m ssen sich mit den Anweisungen zur Installation und Verdrahtung vertraut machen und m ssen die Anforderungen aller geltenden Vorschriften Gesetze und Normen kennen Aktivit ten wie Installation Einstellung Inbetriebnahme Verwendung Montage Demontage und Instandsetzung m ssen durch ausreichend geschultes Personal in bereinstimmung mit den geltenden Durchfiihrungsvorschriften ausgef hrt werden Wenn diese Ausr stung in
17. Product Information Allen Bradley Configurable NAT Router Catalog Number 1783 NATR A ATTENTION Read this document and the documents listed in the Additional Resources section about installation configuration and operation of this equipment before you install configure operate or maintain this product Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes laws and standards Activities including installation adjustments putting into service use assembly disassembly and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice If this equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired TER TER WS PREMISED AS mi GA SCM HR Eo OA ae ER ESA OCS BR TPA IE te BAAS BEEZ FAP Rw AS EA Tt AH Ae NS Hz EH AR PE EIA ERE 2 Tree AAR A R F E E FE BRE ST Di RAS Fa HG lem Te D FT EA MI RR Sa EE AR o ATENCION Antes de instalar configurar poner en funcionamiento o realizar el mantenimiento de este producto lea este documento y los documentos listados en la secci n Recursos adicionales acerca de la instalaci n configuraci n y operaci n de este equipo Los usuarios deben familiarizarse con las instrucciones de instalaci n y cableado y con los requisitos de todos los c digos leyes y est ndares vigentes El pers
18. RISQUE D EXPLOSION Lo e Couper le courant ou s assurer que l environnement est class non dangereux avant de d brancher l quipement e Couper le courant ou s assurer que l environnement est class non dangereux avant de d brancher les connecteurs Fixer tous les connecteurs externes reli s cet quipement l aide de vis loquets coulissants connecteurs filet s ou autres moyens fournis avec ce produit e La substitution de composants peut rendre cet quipement inadapt a une utilisation en environnement de Classe I Division 2 e S assurer que l environnement est class non dangereux avant de changer les piles European Hazardous Location Approval The following applies to products marked CE e Ex Il 3 G Such modules e Are Equipment Group Il Equipment Category 3 and comply with the Essential Health and Safety Requirements e relating to the design and construction of such equipment given in Annex II to Directive 94 9 EC See the EC e Declaration of Conformity at http www rockwellautomation com products certification for details e The type of protection is Ex nA IIC T4 Gc according to EN 60079 15 e Comply to Standards EN 60079 0 2012 A11 2013 EN 60079 15 2010 reference certificate number DEMKO 15 ATEX 1459X e Are intended for use in areas in which explosive atmospheres caused by gases vapors mists or air are unlikely to e occur or are likely to occur only infrequently and for short periods Such loca
19. a Gli utenti devono leggere e comprendere le istruzioni di installazione e cablaggio oltre ai requisiti previsti dalle leggi codici e standard applicabili O EMSS HEN AD INHAS ASAE gt SAB SoA HOF UE LIEF ost oli A T Le attivit come installazione regolazioni utilizzo assemblaggio disassemblaggio e manutenzione devono essere svolte da personale adeguatamente addestrato nel rispetto delle procedure previste Qualora l apparecchio venga utilizzato con modalit diverse da quanto previsto dal produttore la sua funzione di protezione potrebbe venire compromessa D KKAT Bu r n n kurulumu yap land r lmas i letilmesi veya bak m ncesinde bu dok man ve bu ekipman n kurulumu yap land r lmas ve i letimi ile ilgili lave Kaynaklar b l m nde yer listelenmi dok manlar okuyun Kullan c lar y r rl kteki t m y netmelikler yasalar ve standartlar n gereksinimlerine ek olarak kurulum ve kablolama talimatlar n da renmek zorundad r Kurulum ayarlama hizmete alma kullanma par alar birle tirme par alar s kme ve bak m gibi aktiviteler sadece uygun e itimleri alm ki iler taraf ndan y r rl kteki uygulama y netmeliklerine uygun ekilde yap labilir Bu ekipman retici taraf ndan belirlenmi amac n d nda kullan l rsa ekipman taraf ndan sa lanan koruma bozulabilir ERRA TERR RE PRIME AE mi oC AU PES HER APAMA iE RERA A Wo MERE GPT ATE RL mue a N
20. ct to investigation by the local Authority Having Jurisdiction at the time of installation WARNING EXPLOSION HAZARD Lo e Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous e Do not disconnect connections to this equipment unless power has been removed or the area is known to be nonhazardous Secure any external connections that mate to this equipment by using screws sliding latches threaded connectors or other means provided with this product e Substitution of components may impair suitability for Class Division 2 e If this product contains batteries they must only be changed in an area known to be nonhazardous Informations sur l utilisation de cet quipement en environnements dangereux Les produits marqu s CL I DIV 2 GP A B C D ne conviennent qu une utilisation en environnements de Classe Division 2 Groupes A B C D dangereux et non dangereux Chaque produit est livr avec des marquages sur sa plaque d identification qui indiquent le code de temp rature pour les environnements dangereux Lorsque plusieurs produits sont combin s dans un syst me le code de temp rature le plus d favorable code de temp rature le plus faible peut tre utilis pour d terminer le code de temp rature global du syst me Les combinaisons d quipements dans le syst me sont sujettes inspection par les autorit s locales qualifi es au moment de l installation WARNING
21. ction Properties menu check Ethernet Protocol TCP IP and click Properties Ce General Advanced Connect using ES Broadcom NetXtreme 57xx Gigabit Cc This connection uses the following items E Brix and Printer Sharing for Microsoft Networks al M iPass Protocol IEEE 802 1 v3 4 9 0 M Internet Protocol TCP IP v amp Description Transmission Control Protocol Internet Protocol The default wide area network protocol that provides communication across diverse interconnected networks C Show icon in notification area when connected Notify me when this connection has limited or no connectivity d From the Ethernet Protocol TCP IP Properties menu change the IP address to 192 168 1 3 and subnet mask to 255 255 255 0 nternet Protocol TCP IP Properties ne K General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 192 168 1 3 Subnet mask 255 255 255 0 Default gateway Use the following DNS server addresses Alternate DNS server Preferred DNS server Cancel 3 ClickOK 4 Install the SD card into the device 5 Set all DIP switches to the OFF position 6 Apply power to the device 7 Go to Start All Programs Rockwell Soft
22. ebruik stellen gebruiken monteren demonteren en het uitvoeren van onderhoud mogen uitsluitend worden uitgevoerd door hiervoor opgeleid personeel en in overeenstemming met de geldende praktijkregels Indien de apparatuur wordt gebruikt op een wijze die niet is gespecificeerd door de fabrikant dan bestaat het gevaar dat de beveiliging van de apparatuur niet goed werkt 2 Configurable NAT Router ATTENTION If this equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired gt ATTENTION Read this document and the documents listed in the For More Information section about installation configuration and operation of this equipment before you install configure operate or maintain this product Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes laws and standards gt ATTENTION Activities including installation adjustments putting into service use assembly disassembly and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice In case of malfunction or damage no attempts at repair should be made The module should be returned to the manufacturer for repair Do not dismantle the module gt ATTENTION This equipment is certified for use only within the surrounding air temperature range of
23. einer Weise verwendet wird die nicht vom Hersteller angegeben wurde kann der von der Ausr stung bereitgestellte Schutz beeintr chtigt sein ATTENTION Lisez ce document et les documents list s dans la section Ressources compl mentaires relatifs l installation la configuration et le fonctionnement de cet quipement avant d installer configurer utiliser ou entretenir ce produit Les utilisateurs doivent se familiariser avec les instructions d installation et de c blage en plus des exigences relatives aux codes lois et normes en vigueur Les activit s relatives l installation le r glage la mise en service l utilisation l assemblage le d montage et l entretien doivent tre r alis es par des personnes form es selon le code de pratique en vigueur Si cet quipement est utilis d une fa on qui n a pas t d finie par le fabricant la protection fournie par l quipement peut tre compromise Fo ME Mal MY tS FE SA apa7 Moll EMS EEH Mal AY ol Apso get gn Ae au DEH AS Ht 2 FEA State ASO Chol HOA Mal BAM ABS Salo el Adal FY IS AS AE Sai QIUS SSE TAS BH Fol wet Wwe ass we Sauls MAA BAHI SE yog Asa Hilo Hs soleil LUAU ATTENZIONE Prima di installare configurare ed utilizzare il prodotto o effettuare interventi di manutenzione su di esso leggere il presente documento ed i documenti elencati nella sezione Altre risorse riguardanti l installazione la configurazione ed il funzionamento dell apparecchiatur
24. ivate port link that is established at 10 Mbps Module is ready to communicate Flashing yellow Data transmission in progress at 10 Mbps PUBLICPORT Off No data is being transmitted Green Public port link established at 100 Mbps Module is ready to communicate Flashing green Data transmission in progress at 100 Mbps Yellow Public port link established at 10 Mbps Module is ready to communicate Flashing yellow Data transmission in progress at 10 Mbps 1 SD card errors including missing and unresponsive cards are considered recoverable faults HE RoHS fa FFB ER China RoHS Compliance Table BBE AA BK AER Component Name Hazardous substances n ER E TUN BURA ZREN Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated Pb Hg Cd Chromium Biphenyls Dipheny Cr VI PBB Ethers PBDE WH Housing E Apl EE BS ie 20 4 Printed Circuit Board Assemblies elo Cs Kae ce Metal Se ASFERE EF SJ T 11364 DIEN Ea Hill This table is made per guidance of SJ T 11364 0 RANGA EAA A ere DF 0 Indicates that this hazardous substance contained in all of the homogeneous materials for the part is below the limit requirement in GB T 26572 X RRA BBD EERE NSE Ju H Eh K REK X Indicates that this hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in GB T 26572 AWE ARSE PO TUT EZ PST O WER RTE AT IE
25. nta demonta oraz konserwacj musz by wykonywane przez odpowiednio przeszkolony personel zgodnie z obowi zuj cym kodeksem post powania Je li urz dzenie jest u ytkowane w spos b inny ni okre lony przez producenta zabezpieczenie zapewniane przez urz dzenie mo e zosta ograniczone OBS L s detta dokument samt dokumentet som st r listat i avsnittet vriga resurser om installation konfigurering och drift av denna utrustning innan du installerar konfigurerar eller b rjar anv nda eller utf ra underh llsarbete p produkten Anv ndare m ste bekanta sig med instruktioner f r installation och kabeldragning f rutom krav enligt g llande koder lagar och standarder tg rder som installation justering service anv ndning montering demontering och underh llsarbete m ste utf ras av personal med l mplig utbildning enligt l mpligt bruk Om denna utrustning anv nds p ett s tt som inte anges av tillverkaren kan det h nda att utrustningens skyddsanordningar f rs tts ur funktion LET OP Lees dit document en de documenten die genoemd worden in de paragraaf Aanvullende informatie over de installatie configuratie en bediening van deze apparatuur voordat u dit product installeert configureert bediend of onderhoudt Gebruikers moeten zich vertrouwd maken met de installatie en de bedradingsinstructies naast de vereisten van alle toepasselijke regels wetten en normen Activiteiten zoals het installeren afstellen in g
26. on In this state the 1783 NATR is configured to be a non supervisor ring node the Public port responds to the default IP address of 169 254 1 1 and the Private ports are configured for DHCP e When a switch is pushed to the left it is in the Off position e Whena switch is pushed to the right it is in the On position e To configure the Private ports with a static address move switch 1 to the Off position and switch 2 to the On position e To enable Ring Supervisor mode with the current supervisor related parameters move switch 3 to the On position e To restore the factory default settings and suspend operation move switch 1 and 2 to the On position When switch 1 and 2 are in the On position the position of switch 3 is ignored When operation is suspended the OK status indicator blinks red To resume normal operation move the switches to the desired positions and cycle power to the 1783 NATR Rockwell Automation Publication 1783 PC017A EN P March 2015 6 Configurable NAT Router Use the Device To start using your device follow this procedure For information about the status indicators on the device refer to the status indicator functions on page 17 1 Connect the Private port of the 1783 NATR to the LAN card of your computer by using an Ethernet patch cable or cross over cable and follow these steps 2 Choose Start gt Network gt Network and Sharing Center gt Change Adapter Settings c From the Local Area Conne
27. onal debidamente capacitado debe realizar las actividades relacionadas a la instalaci n ajustes puesta en servicio uso ensamblaje desensamblaje y mantenimiento de conformidad con el c digo de pr ctica aplicable Si este equipo se usa de una manera no especificada por el fabricante la protecci n provista por el equipo puede resultar afectada ATEN O Leia este e os demais documentos sobre instala o configura o e opera o do equipamento que est o na se o Recursos adicionais antes de instalar configurar operar ou manter este produto Os usu rios devem se familiarizar com as instru es de instala o e fia o al m das especifica es para todos os c digos leis e normas aplic veis necess rio que as atividades incluindo instala o ajustes coloca o em servi o utiliza o montagem desmontagem e manuten o sejam realizadas por pessoal qualificado e especializado de acordo com o c digo de pr tica aplic vel Caso este equipamento seja utilizado de maneira n o estabelecida pelo fabricante a prote o fornecida pelo equipamento pode ficar prejudicada BHMMAHME Tepen Tem Kak yctTaHaBnBaTb HacTpanBaTb KCNNYATNpOBATb MIN OOCAYKUBaTb AaHHOe OOopyAOBaHue NPOUNTAiTe 3TOT AOKYMeHT N AOKYMeHTHI NeEpeyncIeHHbIe B pa34ene lononpnurentupe pecypcbi Bam AOKYMEHTAX Vi3NOKEHbI CBEAEHMA 06 ycTaHoBKe HactTpo ke n KcnnyaTaynn AaHHOro OOopyAOBaHuaA Tont20parenu OOAZaHbI O3HAKOMMTHCA C MHCTPYKUMAMM NO yCTAHOBKE V DD
28. tains to Stratix Ethernet switches Configurable NAT Router User Manual publication 1783 UM008 Provides information on how to install configure and operate the 1783 NATR device You can view or download publications at http www rockwellautomation com literature To order paper copies of technical documentation contact your local Allen Bradley distributor or Rockwell Automation sales representative Rockwell Automation maintains current product environmental information on its website at http www rockwellautomation com rockwellautomation about us sustainability ethics product environmental compliance page EEE Yonetmelidine Uygundur In Conformity with the EEE Regulation Allen Bradley RSLinx Classic Stratix Studio 5000 Logix Designer and Rockwell Automation are trademarks of Rockwell Automation Inc Trademarks not belonging to Rockwell Automation are property of their respective companies Rockwell Otomasyon Ticaret A S Kar Plaza ls Merkezi E Blok Kat 6 34752 erenk y Istanbul Tel 90 216 5698400 www rockwellautomation com Power Control and Information Solutions Headquarters Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 2496 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automation NV Pegasus Park De Kleetlaan 12a 1831 Diegem Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 10
29. tall the SD card in only one orientation The notch on the SD card points toward the top of the device If you feel resistance when inserting the SD card pull it out and change the orientation 5 Gently press the card until it clicks into place Rockwell Automation Publication 1783 PC017A EN P March 2015 4 Configurable NAT Router Install the NAT Device WARNING For hazardous location applications use the supplied Weidmuller 1317570000 power terminal block gt Follow these procedures to install the 1783 NATR 1 Mount the 1783 NATR in one of these configurations e Panel mount e DIN rail mount Wire the 1783 NATR Connect the Ethernet ports 4 Download the EDS file for the 1783 NATR Configure Internet Protocol settings 6 Set the DIP switches This publication describes these steps in detail Mount the NAT Device Install the 1783 NATR on a DIN rail or panel mount the 1783 NATR Ww N vI IMPORTANT For 1783 NATR devices When mounting the 1783 NATR allow a minimum clearance between product and adjacent equipment of 2 54 cm 1 in on all sides DIN Rail Mounting To install the 1783 NATR on a DIN rail by using these steps 1 Mount your DIN rail 2 Use a screwdriver to open the latch at the bottom of the 1783 NATR 3 Hook the latch over the DIN rail while holding the latch open with your screwdriver 4 Remove the screwdriver and push the latch to close The top figure shows the use
30. the EDS file for the 1783 NATR Obtain the EDS file from http www rockwellautomation com resources eds From the Network pull down menu choose the EtherNet IP network From the Device Type pull down choose Communication Adapter Inthe Bulletin catalog number field type 1783 NATR Click Search Click Download to download the EDS file for the 1783 NATR Save the file to a location on your computer Use your configuration software to register the downloaded file a Ifyou are using RSLinx Classic communication software use the EDS Hardware Installation Tool b Choose Start gt All Programs gt Rockwell Software gt RSLinx gt Tools Upload the Embedded EDS File from the Device 1 Open RSLinx Classic 2 Navigate to your 1783 NATR device CO N Ch LI BW NS 3 Right click the device and select Upload EDS file from device gt ss ss File Edit View Communications Station DDE OPC Security Window Help Si amp SR ell vi Iw Autobrowse o EE Browsing node 192 168 1 1 found Workstation NAUSMAYFFX77W1 dr Linx Gateways Ethernet Z e AB_ETHIP 1 Ethernet dr AB_ETHIP 2 Ethernet z E 192 168 1 1 1783 NATe vd Lage ons Details D E Remove Driver Diagnostics Upload EDS file from device Device Properties Module Statistics Module Configuration 4 Click Next at each EDS window 5 At the successful completion window click Finish
31. tions correspond to Zone 2 classification e according to ATEX directive 1999 92 EC WARNING Special Conditions for Safe Use e This equipment is not resistant to sunlight or other sources of UV radiation e This equipment shall be mounted in an ATEX IECEx Zone 2 certified enclosure with a minimum ingress protection rating of at least IP54 as defined in EN IEC 60529 and used in an environment of not more than Pollution Degree 2 as defined in EN IEC 60664 1 when applied in Zone 2 environments The enclosure must be accessible only by the use of a tool e This equipment shall be used within its specified ratings defined by Rockwell Automation e Provision shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 140 of the rated voltage when applied in Zone 2 environments e Secure any external connections that mate to this equipment by using screws sliding latches threaded connectors or other means provided with this product e Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous gt IEC Hazardous Location Approval The following applies to products with IECEx certification Such modules e Are intended for use in areas in which explosive atmospheres caused by gases vapors mists or air are unlikely to occur or are likely to occur only infrequently and for short periods Such locations correspond to Zone 2 classification to IEC 60079
32. ware BOOTP DHCP Server and open the utility 8 Double click the MAC address 9 Enter 192 168 1 1 for the IP address at the New Entry window and click OK The IP address appears in the Relation List 10 Open RSLinx Classic 11 Navigate to your 1783 NATR device 12 Right click the device and select Upload EDS file from device 13 Click Next at each EDS window 14 Click Finish 15 Open a web browser and navigate to 192 168 1 1 16 Click Configuration and then click one of the links for example Device Services You are prompted to enter a user name and password 17 Enter admin for the user name and the serial number of the device for the password The serial number is the default password You are prompted to enter a new password 18 Enter a new password into the password fields Now you can access the Configuration menu items H Public port or Private port configuration changes were made the device must be reset for the changes to take effect 19 Navigate to Device Services and under Reset Module click Reset Module 20 Configure the module See 1783 UM008 for complete instructions Allen Bradley EE yA LNN Expand Minimize P Home D Diagnostics Device Name 1783 NATR Configuration Device Description Network Address Translation Device Location D Device Identity Public Ethernet Address MAC 00 00 bc 61 1e ca E S Public Network Public IP Address 169 254 1 1 Private Network Private Ethernet Address MAC 0
33. witches to automatically enable Ring Supervisor mode with the current supervisor related parameters stored in the memory of the 1783 NATR Refer to Set the DIP Switches on page 5 for additional information IMPORTANT Use these precautions when setting up a DLR network e Make sure at least one node is acting as supervisor before connecting the last link of a DLR network and physically closing the ring e Do not connect nodes that do not support a DLR as members of the ring Grounding Considerations This product is intended to be mounted to a well grounded mounting surface such as a metal panel or DIN rail ATTENTION This product is grounded through the DIN rail to chassis ground Use zinc plated yellow chromate steel DIN rail to assure proper grounding The use of other DIN rail materials for example aluminum or plastic that can corrode oxidize or are poor conductors can result in improper or intermittent grounding Secure DIN rail to mounting surface approximately every 200 mm 7 8 in and use end anchors appropriately Be sure to ground the DIN rail properly Refer to Industrial Automation Wiring and Grounding Guidelines Rockwell Automation publication 1770 4 1 for more information gt 1783 NATR Device Components 2 E S IL RS j 12 9 8 7 YUT 11 A B 6 pe Ss A 5 o fwe fe 3 Sideview Tn Device port on front panel 4 Daer Im Status