1. This button does not alter any other settings Using the Serial Connectors e Make sure the PDU and your computer are connected to the same subnet on the same network e Connect a serial cable between one of the PDU s configured serial connectors and an external device s serial port The used Baudrates on both devices should be the same e Start a Telnet session at the PDU s IP and with the correct port e You will be asked for login credentials the default values are Login admin Password 1234 e You are now connected please refer to the external device s documentation for more information on the serial connection options 2011 Racktivity Inc 18 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Use Case Requirements e A fully configured PDU with an active ethernet connection e APC with Putty software download it here and an active ethernet connection e Device with a console port ie a Cisco switch e Afemale DB9 to console cable How to e Install Putty e Connect the cable between the PDU s 1st RS232 port and the device s console port e Make sure the PDU and PC are on the same subnet and are switched on e Open Putty and enter the following o Connection Type Telnet o Host name the PDU s IP address ie 192 168 14 250 o Port the default port for RS232 connector 1 is 2001 can be changed at the Web Portal s Serial page e Press Open e You will be asked for login
2. Redwood City 94063 USA www racktivity com v 2013 11 18 The following settings are only available when the DHCP checkbox is unchecked Ethernet Warning when changing these values connection to the Web Portal might be lost e IP Address The IP address used for TCP IP configuration e Subnetmask The subnet mask used for TCP IP configuration e Std Gateway The standard gateway used for TCP IP configuration DNS server The DNS server used for TCP IP configuration DHCP When checked the PDU will automatically be assigned an IP address if a DHCP server is present on the network e Community read Sets the community read string default public When using SNMP software on a pc to collect SNMP data GET command this string is used as verification e Community write Sets the community write string default private When using SNMP software on a pc to change SNMP data SET command this string is used as verification e Write protection When checked this setting will prevent changes being made through SNMP SET command even when using the correct Community write string It can be used as an additional protection e Trap receiver port Sets the port for the SNMP Trap function default 162 e Trap receiver IP Sets the IP address where the SNMP Trap is sent this is normally the IP of a monitoring computer on the same network e Min before Off Sets the OLED standby delay when no buttons are pressed in minutes e Brightness 2 10
3. Sets the OLED s brightness e Login Sets a new login and password The default values are Login admin Password 1234 Logging e Sets the logging values for the Logging tab o Short term From 1 255 seconds o Medium term From 1 255 minutes o Long term From 2 255 medium term intervals specified in the above setting After editing the settings on the Settings tab press the Save Data button A pop up will appear after the changes have been successfully saved Time Settings UTC The following settings are only available when NTP is unchecked e Time HM Sets the time in hours minutes e Date DMY Sets the date in days months years e Local NTP server NTP server IP when Use Default NTP Server is not checked e Use Default NTP server When checked the PDU will connect to pool ntp org for the time settings e NTP When checked the PDU will try to get time settings from an NTP server O 2011 Racktivity Inc 14 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Protection tab Use this tab to set the thresholds and alarms that provide disaster prevention and other recovery functions for each port Port Port name and status Grey background Port is powered OFF Green background Port is powered ON Current Real time current in milliampere Maximum Maximum current in milliamp re since the last reset Reset Resets the Maximum value Hover your mouse over this value to see a t
4. UP and DOWN to select Current IP Address The current IP address is shown in yellow at the bottom of the OLED Firmware Update To obtain the necessary software to update your PDU s firmware please contact Racktivity Support O O a Make sure that your computer and the PDU are on the same network and fully functional Unpack the update package Open the software tool Racktivity Ethernet Bootloader exe Use the File button to select the cry file that came with the update package Fill in the appropriate IP address and login credentials of the designated PDU Press Update firmware to start the update The update has successfully completed when Programming completed Exit bootloader is shown the update takes a few minutes Latest version The latest available firmware version for the PM0816 01 is v1 01 2011 Racktivity Inc 23 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Troubleshooting After starting the update FAILED check Settings is shown Please make sure that e The PDU is powered on and connected to LAN with a correct IP address e You entered the correct login credentials under Settings in the software tool e You are on the same LAN as the PDU To verify the above settings are correct go to the Web Portal and log in The Status window continuously shows output similar to ERROR Out of Sequence PDU Seq 5294 5299 e This is a mere warning and does n
5. Use the UP and DOWN buttons to change the screen brightness Press MENU to save and exit Fa PUR Reporting Screens Overview 1 7 The Overview screen shows the total current in A Amp re the real power usage in Watts the temperature in degrees Celsius and the humidity in RH Relative Humidity These values are updated in real time General 2 7 This screen shows the current in Amp re for all 8 ports A combined total is displayed on the right Tot Current followed by the input voltage in Volts and frequency in Hz All values are updated in real time Ports shown in green are powered on when shown in grey they are powered off 2011 Racktivity Inc 8 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Port State 3 7 Here you can see the current in Ampere for all 8 ports followed by the port name The port name is typically the name of the connected device and can be set via the Web Portal Ports shown in green are powered on when shown in grey they are powered off Changing the port state Press OK Use the UP and DOWN buttons to select the desired port Press OK at the selected port validate by pressing MENU Press MENU again to exit port selection PAN A Power 4 7 This screen shows the Real Power Apparent Power and Power Factor PF values for each of the ports Ports shown in green are powered on when shown in grey they are powered off When the c
6. and back on Toggling a port s state manually ignores this setting Voltage table Value Current voltage measured Warning Min When the measured voltage goes below this threshold an SNMP trap is sent with SNMP checked Warning Max When the measured voltage exceeds this threshold an SNMP trap is sent with SNMP checked SNMP When checked SNMP traps are sent when the measured voltage is below the minimum or above the maximum threshold After editing the settings on the Protection tab press the Save Data button A pop up will appear after the changes have been successfully saved 2011 Racktivity Inc 15 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Serial tab The settings for the PDU s 4 serial connectors can be changed on this tab e Port The number of the serial connector as seen on the front of the PDU e Baudrate Possible baudrates for serial communication The baudrate of the serial connector and a connected device must be the same e TelnetPort Sets the telnet port The port must end in the same number as the corresponding serial connector serial connector 3 cannot have a port ending with 4 ie 30004 it must end with a 3 ie 14203 e Reset Telnet Disconnects an active telnet session This button does not alter any other settings After editing the settings on the Serial tab press the Save Data button A pop up will appear after the changes have been successfull
7. the shipment date of each Product unit to Buyer Warranty Period For purposes of this Agreement the term defect shall mean the Product fails to operate or fails to conform to its applicable specifications Any claim made pursuant to this Agreement shall be asserted or made in writing only by Buyer Buyer shall comply with Racktivity s Standard Return Merchandise Authorization RMA procedure for all warranty claims as set forth in Racktivity s operation manual Buyer must return Products in original packaging and in good condition This limited warranty does not include labor transportation or other expenses to repair or reinstall warranted Products on site or at Buyer s premises The warranty only applies to the original Buyer Racktivity reserves the right to investigate any warranty claims to promptly resolve the problem or to determine whether such claims are proper In the event that after repeated efforts Racktivity is unable to repair or replace a defective Product then Buyer s exclusive remedy and Racktivity s entire liability in contract tort or otherwise shall be the payment by Racktivity of Buyer s actual damages after mitigation but shall not exceed the purchase price actually paid by Buyer for the defective Product Racktivity shall have no responsibility or liability for any Product or part thereof that a has had the Serial Number Model Number or other identification markings altered removed or rendered illegible b h
8. U until the Main menu appears select Ethernet or Network using UP and DOWN and press OK 2 Within the Ethernet or Network menu select DHCP off and press OK until DHCP on appears 3 Press MENU to return to the Main menu and use UP and DOWN to select Current IP Address The current IP address is shown in yellow at the bottom of the OLED 4 Ona computer in the same network use a browser to open the assigned IP address for example http 192 168 14 250 5 When browsing to the Web Portal a popup appears requesting a username and password The default values are Login admin Password 1234 O 2011 Racktivity Inc 10 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Manual IP Address Assignment Obtain the correct IP address standard gateway DNS Server IP and subnet mask from your network administrator 1 Press the MENU button until the Main menu appears select Ethernet or Network using the UP and DOWN buttons and press OK 2 Within the Ethernet or Network menu select DHCP on and press OK until DHCP off appears 3 Select SET IP ADDRESS and press OK to change the settings when navigating the menus the value for that setting is shown in yellow at the bottom of the OLED 4 Use the UP and DOWN buttons to change the currently selected value and press OK to select the next value When holding the UP and DOWN buttons changing the values speeds up When ready press MENU to retur
9. User manual PMOS16 01 Contents Contents aiae Teraa a ei be lars S lee de eh veut evebu suet A EEA rA 2 IntrOdUCtION A Arietta A A A ad 4 Applicable Models id ida a dia iria 4 INVENTORY 2 A E I ADA ia ees ie ae eee 5 Inspectioniof the Packet a area ennen En 5 OVA BAe a 6 PRON ai ceeae arsine eth ee ese a ita 6 O RO 6 Install in ti AA AAA A A AA EA et 7 Motinting the PDU cas a iia Teds aaa 7 ConnectingthePDU sd A OA ae a ae 7 OLED Dil e e 8 Activating the display it aida nodo aida E E A E E A AE 8 Using the displasia IAEA A EA E EEE A A as 8 Setting the DEBIO A A A de ada 8 Reporting Screens tii in a A FN ees 8 OVERVIEW M DA A org A A ee Es 8 General 2 7 cccccccssosccesscsssvscceccsvscceccsunssevesceussvncescceunancodscaccsssocedsdanaseoecccuanovececeedssseseccaussovececeeanate 8 POr State TA A A Ee ee AA ais Rh lass ABER 9 POWER 4 7 aan A otindeduaacl stated ener E E E A NEEE 9 Power Consumption 5 7 ccccsssccessssccecsscccesseseeccssecccaaeccesseseeecsseeccaaeeceesseeecesaeecessaeeceesseeeeeaeess 9 Ambient Mirta O ao beeen SAES 9 Current Of Ports 7 7 ccccccccsssscceesscceecsseeeccssueccesseececesseeccsaceccessesesecsseecesaaeccssaeeesecsteeeesauecessaeeeeenaes 9 TOPP COMTIBUNAT OM A A A wees dE 10 Dynamic IP Address ASSISNMENL ccccccnnnnnononnonononnnnnnnnnnnnonnnnnnnnnnonnnnnnnnnnnnnannnnnnr seende kneben eee 10 Manual lP Address Assign MENE dada 11 Using the Web Portal e ed e Lao 12 Opening
10. as been damaged by or subject to improper installation or operation misuse accident neglect and or has been used in any way other than in strict compliance with Racktivity s operation and installation manual c has become defective or inoperative due to its integration or assembly with any equipment or products not supplied by Racktivity d has been repaired modified or otherwise altered by anyone other than Racktivity and or has been subject to the opening of any sealed boxes without Racktivity s prior written consent If any warranty claim by Buyer falls within any of the foregoing exceptions Buyer shall pay Racktivity its then current rates and charges for such services THE ABOVE WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ALL OF WHICH ARE EXPRESSLY DISCLAIMED RACKTIVITY SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL SPECIAL OR EXEMPLARY DAMAGES EVEN OF IT HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES For warranty issues contact the Product Support Department All repair and return shipments must be approved by Racktivity and must be accompanied by a RMA Return Merchandise Authorization number and dated proof of purchase 2011 Racktivity Inc 21 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Troubleshooting Password Reset Resetting the password can be done on the de
11. ble to the following Racktivity 1U models e PM0816 01 O 2011 Racktivity Inc 4 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Inventory Inspection of the Package Inspect the package see inventory and contents for shipping damage and make sure that all parts were received Immediately report any damage from shipping to the shipping agent and missing content damaging or other problems to your reseller Please verify the contents of the package Standard Package Item Quantity PDU 1 Rack mounting brackets Rack mounting bracket screws PDU Power cable 3 meter Installation manual PPA N 2011 Racktivity Inc 5 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Overview Front 1 TEMP 2 ANTENNA 3 RS232 4 CONSOLE 5 LAN 6 OUTPUT 7 OLED 8 UP 9 DOWN 10 MENU 11 OK 12 ALARM 13 POWER Rear 1 FUSE INLET OUTLET 4 AIRFLOW 5 TEMP 2011 Racktivity Inc 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com N A N A 4 x RS232 interface connector Console connector Ethernet connector LED Status LED is on Ethernet connection established Status LED is flashing Ethernet activity on the network Blue LED activity indicator for each of the 8 ports OLED display Move to the previous page or browse upwards in a selection list Move to the next page or browse downwards in a sel
12. credentials the default values are Login admin Password 1234 e Many devices require that you press the Enter key a few times before anything can be seen You are now connected to the device s console port through ethernet Up to 4 devices can be connected to the PDU s RS232 connectors SNMP MIB Files Download the MIB files appropriate to your firmware from the Support section O 2011 Racktivity Inc 19 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Specifications Devices Connectable Supported Voltages RS232 ports Networking SNMP Monitoring alerting and management Remote control software Integrated Remote Control Web server Max current per port Max current per PDU Enable Disable ports Form factor Color graphical OLED Display LED Indicators Rack Mountable Power consumption Steel Case Control buttons on front Automatic Fuse Hardware 15 Amp re Microcontrolled based Fuse on each port Internal Temperature 2011 Racktivity Inc 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com 8 110 220V 4 Ethernet Yes Yes Yes 8A 15A Yes 1U Yes Yes Yes 4 watt Yes Yes Yes Yes Yes 20 25 v 2013 11 18 PDU Family Warranty Warranty and Limitation of Liability Racktivity agrees to repair or replace Datacenter Management Units Products that fail due to a defect within twenty four 24 months after
13. e full benefits of SNMP monitoring Software like Reasoning s MIB Browser can help get results quickly while Zenoss monitoring software takes a more in depth approach O 2011 Racktivity Inc 17 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Serial Configuration The PDU has 4 serial RS232 connectors located at the front to connect upto 4 external devices ie switches server s These connectors are primarily for recovery purposes so when you have been locked out of an external device you can still connect to it through Telnet using the PDU s ethernet connection Configuring the serial connectors e Make sure that the PDU has been properly configured for use on the network For more info see TCP IP Configuration e Use a browser to open the PDU s IP address You will be asked for login credentials the default values are Login admin Password 1234 e Go to the Serial tab Here you can specify for each connector e Port The number of the serial connector as seen on the front of the PDU e Baudrate Possible baudrates for serial communication The baudrate of the serial connector and a connected device must be the same e TelnetPort Sets the telnet port The port must end in the same number as the corresponding serial connector serial connector 3 cannot have a port ending with 4 ie 30004 it must end with a 3 ie 14203 e Reset Telnet Disconnects an active telnet session
14. ection list Button to access menu function Validation button Red alarm LED indicator Blue power LED indicator 15A circuit breaker 16A inlet IEC C20 8x outlet plug Note maximum load of 8A on each of the ports amp 15A in total N A N A 6 25 v 2013 11 18 Installation Mounting the PDU The PDU comes with brackets for mounting in a rack e Choose the appropriate location for the brackets on the sides of the unit depending on the desired deepness e Attach the rack mounting brackets to the unit using 2 retaining screws provided for each of the brackets Attach the PDU to a vertical rail in your rack Position the PDU align the buttons with the rack mounting slots and fix the PDU with the required screws not inserted in the package When mounting the device ensure that nothing is leaning on or close to the PDU Best is to leave open space for airflow and to assure accurate internal temperature measurements The PDU itself is a low power device with a power consumption of only 2 Watt Connecting the PDU gt The PDU has a detachable power cord Attach the included power cord to the device by inserting the IEC C20 connector in to the IEC C20 inlet Note Optionally a user supplied power cord can be attached to the PDU by connecting it to the IEC inlet Do not attempt to attach a user supplied power cord unless it is certified to be compatible with the input power source that will be used by the PDU Connect the in
15. imestamp that indicates when the maximum value was measured Warning Level When this threshold in milliamp re is exceeded an SNMP Trap is sent if the SNMP checkbox for this port is checked Off Level when this threshold in milliamp re is exceeded the port is automatically powered off and an SNMP trap is sent if the SNMP checkbox for this port is checked Temp Off When this temperature threshold in C is exceeded by the internal temperature sensor the port is automatically powered off and an SNMP trap is sent if the SNMP checkbox for this port is checked SNMP When checked SNMP Traps are enabled for this port Priority o The PDU looks at the thresholds of each port before checking the SUM So if a port exceeds its Off Level threshold that port is powered off followed by a check of the SUM Off Level threshold o When the Off threshold in the SUM row is exceeded the device looks at the individual port priority settings to determine which port to power down first second even when it wasn t that port that caused the threshold to be exceeded A lower number means a higher priority 1 is the highest priority 8 the lowest o If 2 ports have the same priority level the PDU will determine which port had the highest current increase and will power off that port If no current increase is found the port that was powered on last is powered off Delay On sets the startup delay in seconds after the PDU has been powered off
16. n to the Ethernet or Network menu 5 Repeat the last 2 steps for the Subnet mask Std Gateway and DNS Server settings 6 Onacomputer in the same network use a browser to open the chosen IP address for example http 192 168 14 250 7 When browsing to the Web Portal a popup appears requesting a username and password The default values are Login admin Password 1234 O 2011 Racktivity Inc 11 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Using the Web Portal Opening the Web Portal Use a browser to open the PDU IP address You will be asked for login credentials the default values are Login admin Password 1234 Status tab e The Status Screen shows the ON OFF status of the 8 ports on the PDU o Grey background port is powered OFF o Green background port is powered ON e The button underneath each port toggles the port status instantly even when a delay has been set on the Protection tab The load is activated at the zero crossing of the voltage to avoid interference on the voltage Toggling a port state always triggers an SNMP Trap regardless of other settings e For each port the real time True RMS is displayed in Amp re e The default port names port1 port2 can be changed at the Settings tab Power tab This tab shows all the power measurements in real time e Port Port name and status o Grey background Port is powered OFF o Green background Port i
17. on The PDU features both access to SNMP data and the ability to send SNMP Traps Configuring SNMP e Make sure that the PDU has been properly configured for use on the network e Use a browser to open the PDU s IP address You will be asked for login credentials the default values are Login admin Password 1234 e Go to the Settings tab e Under the SNMP section you will find the following O Community read Sets the community read string default public When using SNMP software on a pc to collect SNMP data GET command this string is used as verification Community write Sets the community write string default private When using SNMP software on a pc to change SNMP data SET command this string is used as verification Write protection When checked this setting will prevent changes being made through SNMP SET command even when using the correct Community write string It can be used as an additional protection Trap receiver port Sets the port for the SNMP Trap function default 162 Trap receiver IP Sets the IP address where the SNMP Trap is sent this is normally the IP of a monitoring computer on the same network SNMP Usage Monitoring software with SNMP functionality enables you to stay on top of any developments concerning the PDU All relevant data measurements settings port states thresholds are accessible through SNMP GET requests Make sure to load the Racktivity MIB file found here to get th
18. ot compromise the update The update fails and the PDU becomes unresponsive e f needed restore power and or Ethernet to the PDU e Repeat the steps above to start the update again In case you need to know the IP address and it cannot be retrieved using the regular methods then e Connect a console cable between the PDU and your pc e Use the following settings to read the output Baudrate 38400 8 databits no parity 1 stopbit e Reboot the PDU the currently used IP address is shown in the console output e Repeat the steps above to start the update again 2011 Racktivity Inc 24 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Support Feel free to contact us if you need any support or have any other questions or remarks Online www racktivity com support E mail support racktivity com Phone 003293242095 GMT 1 2011 Racktivity Inc 25 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18
19. put plug to a compatible AC power outlet Note The AC power source should not share a circuit with a heavy electrical load Connect your equipment s input plugs to the outlet plugs of the PDU Only when the appropriate port status LED is lit does the PDU provide power to that port All blue port status LEDs will light up at first time use Note When not first time use it is possible that not all LEDs light up The PDU will only activate those ports that were active when power was shut down Non lit ports are not active O 2011 Racktivity Inc 7 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 OLED Display Activating the display The OLED standby delay can be set at the Settings page on the Web Portal the default value is 1 minute On the PDU push any of the 4 buttons next to the OLED Display to activate the screen Using the display The OLED is controlled using the UP DOWN MENU and OK buttons next to the screen Use the UP and DOWN buttons to navigate through the reporting screens or through a selection list in the menus Press OK to select the highlighted item and MENU to go back When in a menu the gt symbol indicates that clicking this item will open a submenu The e symbol indicates that this menu item leads directly to a setting Setting the brightness Press the MENU button until the Main menu appears Select Brightness using the UP and DOWN buttons and press OK
20. s powered ON e Current The real time current is displayed in Amp re e Maximum The maximum current measured in Amp re Hover your mouse over this value to see a timestamp that indicates when the maximum value was measured This value can be reset at the Protection tab e Real Power The real power usage in Watts e Apparent Power The apparent power in Volt Amp re e Power Factor The power factor in e Resettable kWh The total amount of kilowatt hours since the last reset e Resettable kVAh Total apparent power in kilo Volt Amp re hours since the last reset e Reset Resets the Resettable kWh and the Resettable kVAh note this reset will not clear the maximum column this can be done at the Protection tab e kWh The total kilowatt hours since the PDU has been in use This value can NOT be reset The default port names port1 port2 can be changed at the Settings tab 2011 Racktivity Inc 12 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Ambient tab The Ambient tab shows the environmental parameters being measured Sensor e Airflow The airflow measured by an optional external sensor in meters per second e Intrusion1 Shows the state of an optional external intrusion detector e Intrusion2 Shows the state of an optional external intrusion detector Relative Humidity e Value The current relative humidity in RH e Min The lowest value since the last rese
21. t in RH e Max The highest value since the last reset in RH e Reset resets the Min and Max columns to the current value e Warning Min Sets the minimum value at which an SNMP trap is sent e Warning Max Sets the maximum value at which an SNMP trap is sent e SNMP if checked SNMP traps will be sent when the Warning Min and or Warning Max values are crossed Temperature e Temperature Shows the state of both the internal temperature sensor on the first row and any connected optional temperature sensors o Grey background No sensor connected o Green background Connected and active sensor Value The current temperature in C e Minimum The lowest value since the last reset in C e Maximum The highest value since the last reset in C e Reset Resets the Minimum and Maximum columns to the current value e Warning Level Sets the maximum temperature that when crossed causes an SNMP trap to be sent e SNMP If checked SNMP traps are sent when the Warning Level is exceeded After editing the settings on the Ambient tab press the Save Data button A pop up will appear after the changes have been successfully saved Settings tab General e PDU Name Name of the PDU e Rack Position Optional administrative parameter that indicates where the PDU is installed Port Name e Sets the preferred port names typically the internal identification used for the connected devices 2011 Racktivity Inc 13 25 2100 Seaport Blvd Suite 400
22. the Web Portal oooocccnccnnnnnnnnncnnnnninnnnnnnnnnnnnnn T 12 SNMP ContiBguratiON 0 A AA A A A A EG E RARE 17 Configure SNMP a ode 17 SNMPUS ABS O crio ii eis E EEE dd lid dali 17 Serial Co e e o ne 18 Configuring the serial CONNECTOFS ccccccccnnccnncnnnnnnannnnnanonanononnnnnnonnnnnnnnnnnnnnnnnnnnnnnnnnnannnr nono nn nnnnnnnannos 18 Using the Serial CONNECTIONS moret A ee ahs a ES 18 O 19 SNMP MIB Ele cid tdt 19 O 2011 Racktivity Inc 2 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Specifica OO r a A AGE 20 PDU Family Warranty iener eeen aei aaeei aeaa eaaa e aasa aee se aa aa aae aae t eaea ai iaaa 21 Warranty and Limitation of Liability oooococcnccnnnninnnnnnnnnanonanononononnnnnnnnnonnnnnnononononnnnnnnnnnnnnns 21 To e e o a 22 Password Reset nd rob be een reis 22 Factory RES Odia A A E DAR E AEREA E DAA AA AA a A 22 Determine Your Fife aen ERE ER E A L A EAT Re OAA 22 Web Portal ari 3 rear di eee da 22 OLED Dis Play 2 ia Eb ee dd 22 Determine Your IPAddress saa ra ad henne add is 23 Firmware Update A a nens 23 LES UN ii ts 23 TrOUublESHOGUN EERE A A WARES wcities 24 SUPPOM ioe ate is ME ee ie eee es dn E Le 25 2011 Racktivity Inc 3 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Introduction Applicable Models Unless specified otherwise all information in this document is applica
23. urrent of a particular port has reached the preset Warning threshold the values will turn orange When the Off threshold is exceeded the port will be powered off and the values will turn red Power Consumption 5 7 This screen shows the power consumption expressed in kilowatt hour and kilovolt A hour for each of the 8 ports Ambient 6 7 When external temperature probes are connected up to 8 they will show up here The internal temperature C humidity RH and an optional external airflow sensor meters second are also displayed on this screen Current of Ports 7 7 This screen shows a real time graph of the used current for each port in Amp re When the Warning and or Off threshold have been set an orange Warning and or red Off line will appear The thresholds can be set using the Web Portal 2011 Racktivity Inc 9 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 TCP IP Configuration There are two methods for setting up the IP address Dynamic IP Address assignment and Manual IP Address assignment If you are uncertain which method to use contact your network administrator for assistance before continuing the installation process Dynamic IP Address Assignment Connect the PDU to a network While the PDU is powered on connect a standard Ethernet cable to the RJ45 Ethernet port the activity LED will light up to indicate Ethernet connectivity 1 Press MEN
24. vice itself e Press and hold the UP and DOWN buttons simultaneously for 4 seconds e The password will now be reset to the factory default settings Login admin Password 1234 This reset only affects the login credentials no other settings are changed Factory Reset If you would like to reset the PDU to the factory default settings this can be done on the device itself WARNING This will completely erase all settings and could power down all ports Make sure no vital equipment is connected to the PDU when performing a Factory Reset e Press and hold the MENU and OK buttons simultaneously for 4 seconds e The device is now completely erased of user specified settings the default login values are Login admin Password 1234 Determine Your Firmware Web Portal Open the Web Portal on the PDU The firmware version is displayed in the top right corner after you log in next to SW V your firmware version OLED Display On the PDU open the Main menu then select Version Numbers followed by Software Version The firmware version is displayed at the bottom of the OLED in yellow O 2011 Racktivity Inc 22 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 Determine Your IP Address To determine the IP address currently used by the PDU first choose your firmware version Press MENU until the Main menu appears select Network or Ethernet using UP and DOWN and press OK Use
25. y saved Schedule tab Here you can specify a schedule which defines for each port if and when it should be turned off and or on and if this should be repeated on a daily basis e Port Port name and status o Grey background Port is powered OFF o Green background Port is powered ON e Time Off Time in hours minutes when the port is to be turned off with Off Enable checked e Off Enable When checked the port will be turned off at the time specified in Time Off e Time On Time in hours minutes when the port is to be turned on with On Enable checked e On Enable When checked the port will be turned on at the time specified in Time on e Repeat Daily When checked the specified schedule for that port will be repeated daily The current time is displayed below the table After editing the settings on the Schedule tab press the Save Data button A pop up will appear after the changes have been successfully saved Logging tab The PDU s short medium long and event logging are displayed on this tab For each type the number of items needed can be specified Changing the logging intervals can be done at the Settings tab O 2011 Racktivity Inc 16 25 2100 Seaport Blvd Suite 400 Redwood City 94063 USA www racktivity com v 2013 11 18 SNMP Configuration SNMP Simple Network Management Protocol is mostly used in network management systems to monitor network attached devices for conditions that warrant administrative attenti