Home

user guide - Me My Elos

image

Contents

1. Gs Love 3 Select the elos level you want to use by pressing wy i the appropriate elos Level button High Medium or e Low the active level will illuminate a white indicator Medium light Refer to the chart on page 15 ofthe user guide to set the right elds level for your skin type 4 Observe the elds cartridge indicator the elos cartridge is pre loaded with a set number of pulses for your use the counter starts at 100 and decreases as you use it The amount of pulses remaining in the elds cartridge is indicated by the lights onthe panel as shown in the illustration in the next page Once the elos cartridge reaches 5 of its capacity a red light will start blinking and at 0 the red light will remain on indicating that the elds cartridge must be replaced and you should stop using the current elos cartridge Note it is safe to use the system untill a constant red light appears near the 0 EN 13 How to replace your elds cartridge 1 Make sure that the me my elos device is turned off 2 Remove the old elos cartridge from the applicator by pressing the 2 release buttons on its side and gently pulling it out 3 Take the new elos cartridge out of its protective container avoid touching the lens Slide the cartridge gently into the applicator until you feel it click into place oy le wie gt Li ow 4 Before turning on the system the applicator must be placed in the c
2. 2 Children should be supervised to ensure they do not play with the device 3 The devices should not be turned on via an outside timer or a separate remote control system 4 WARNING Do not use this apparatus near bathtubs showers sinks and other receptacles containing water EN 7 System description Your m my elos system is designed to be easy to use and is easy to maintain The system is comprised of the following components 1 Base unit 4 elos cartridge 2 Control panel 5 Epilator cartridge 3 Applicator 6 Shaver cartridge Epilator and Shaver are sold separetly EN The treatment is done using the elos cartridge and if you like you simultaneously use the epilator or shaver cartridges Sold separately 1 elos cartridge a Intense pulsed light IPL output window a Radiofrequency RF delivery bars 2 Epilator cartridge a Rotating epilating mechanism 3 Shaver cartridge a Foil covered shaver combined with a trimmer EN 9 How to prepare the m my elds system for operation The m my elos system is easy to use and easy to care for Your new m my elos system arrives from the factory with the elos cartridge and epilator protective cap already connected to the applicator 1 If you want to use the epilator or shaver you should remove the protective cap press the two blue buttons to slide 10 EN one ca
3. Treatment 1 Press the power button to turn the system on 2 Select the elos level by pressing the button near the appropriate level based on the attached table 3 Press the elos activation button 4 Press the epilator shaver activation button to select desired speed Epilator and shaver are sold separately 5 Ensure you are touching the two grip sensors 6 Hold the applicator in a position ensuring full contact of the RF delivery bars with the skin Do not press just gently touch the skin System will start emitting elos pulses 7 Use the system in either circular movements or slow back and forth strokes Treatable Skin Types Skin Type 1 Pale white skin always burns does not tan elos Level High Skin Type 2 Fair skin burns easily rarely tans elos Level High Skin Type 3 Darker white skin tans after initial sunburn elos Level High Skin Type 4 Light brown skin burns minimally tans easily elos Level Medium to High Skin Type 5 Brown skin rarely burns tans dark amp easily elos Level Low to High Skin Type 6 Dark brown or black skin never burns dark tan Do not use the me my elos system Note If you feel discomfort treat at a lower level If tolerable increase the elos setting for higher efficacy Note Do not use me my elos if your skin has had long exposure the sun within the last three days Note During treatment DO NOT hold the
4. s it i tp J EN 19 m my elos treatment procedure choosing your cofiguration Syneron recommends that you integrate your tried and true hair removing habits with your new me my elos system a If you are used to using a razor you can shave the treated area before using the elos cartridge only Remember to maintain the time of treatment and protocol as illustrated a lf you are used to using a shaver you should now use the me my elos system with the elds and shaver cartridges m f you are used to using an epilator you should now use the m my elds system with the elos and epilator cartridges a If you are used to any combination of shaving or epilating in different areasof your body use the me my elos system in the same method When treating light hair it is recommended to use the elos epilator combination for higher efficacy Treatable skin types II IV 20 EN DO NOT USE Treatment durations For effective results me my elos should be used according to the following durations hd 2 minutes 1 minute 3 minutes 10 minutes When to use m my elds Fam 1 week 2 weeks em 3 weeks 4 weeks 5 weeks 6 weeks treatment treatment 1 perform first 4 treatments every 2 weeks 2 after first 6 weeks use m my elos as hair appears Note Treatment intervals refer to the use of 5 Place the applicator in its cradle in the the e
5. just moist Warning do not rinse in water any part of the system 22 EN Important Note Do not use any household cleaning agents Cleaning the shaver cartridge 1 Turn the system off and unplug the electrical power cable from the wall socket 2 Remove the shaver cartridge by pressing the release buttons and sliding it off the applicator 3 Remove the foil covered blade assembly from the shaver cartridge by pulling it out 4 Use the supplied cleaning brush to clean the blade assembly 5 Clean the bottom of the shaver cartridge with the cleaning brush supplied 6 Insert the blade foil into the shaver cartridge again 7 Putthe shaver cartridge back on again Push down the shaving head until it catches a on a Stee 7 Raw es Troubleshooting Here is what you should do if any problems arise with your m my elds system If the m my elos system will not start a Check the system s power cable it should be connected to the system and to the wall outlet If light pulses are not emitted from the elds cartridge a Make sure that both sides of the applicator have a cartridge or a protective cap well inserted a The green indicator next to the power button should be on If the indicator is orange this means that the system is turned off Press the power button to turn the system on a The white elos indicator on the applicator should be continuously illuminated A flashing white indicator
6. insert the epilator protective cap provided to allow system operation 3 Press the epilator shaver cartridge activation button once to run the epilator mechanism at low speed the number 1 indicator will light up 4 If desired press it again to run the epilator mechanism at high speed the number 2 indicator will light up 2 Press the elos activation button on the applicator once to turn it on the white indicator will light up and a fan will start to operated the applicator elds activation button DY oo grip sensors P we Important Note The shaver cartridge under foil cover operates only at speed 1 EN 17 Important Note The elos activation button will automatically turn itself off if no pulses have been emitted for one continuous minute 5 With the thumb and forefinger of your hand lightly touch the two grip sensors one on each side of the applicator 6 Apply the tip of the applicator on your skin in such a way that the two RF delivery bars are in complete contact with the skin 7 Once full contact is achieved you will notice light flashes indicating that the system is operating It is recommeded to use the system under broad light environment Important Note It is not recommended and there is no need to look directly at the light flashes 8 Use the system as you would use an epilator shaver either circular movements or back and forth strokes 9 Move the app
7. means that the elos cartridge or epilator shaver cartridge or epilator shaver cap is not inserted correctly Re insert the cartridge cap a The elos cartridge display on the base unit s control panel should show an indicator next to any of the percentage values 100 80 etc or a blinking red light next to the empty indicator If the red Empty indicator is continuously lit it is time to insert a new elds cartridge a During treatment make sure that the RF delivery bars are in contact with your skin and that you are touching the grip sensors on the sides of the applicator a Make sure that the Error indicator above the power button is not illuminated If it is Turn the system off a Unplug it from the wall electrical outlet a Wait 1 minute m Reconnect the power cable to the electrical outlet a Turn the system back on If none of these suggested measures seem to help contact your local provider for support EN 23 Specifications Light spectrum s 550 1200 nm Max elos energy 9J cm2 Max Optical 4 cm2 Conducted RF 5 cm2 in equivalent optical units Pulsed light repetition rate Up to 2 pulses second 2 Hz RF Wave frequency a 6 78 MHz Radiofrequency power Acceptable Environmental Conditions eo Wale Storage and transportation Coverage rate elos cartridge pulse life Humidity 90 at 55 C 137 F a 3 000 pulses Pressure 700 1060hPa Electrical power input 200 240 VAC 50 H
8. patent rights of Syneron Medical Ltd No part of this document may be produced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Syneron Medical Ltd Syneron Medical Ltd has patents and pending patent applications trademarks copyrights or other intellectual property rights covering subject matter in this document 26 EN The furnishing of this document does not give any license to these patents trademarks copyrights or other intellectual property rights except as expressly provided in any written agreement from Syneron Medical Ltd Specifications are subject to change without notice Be sure to read all instructions carefully before starting treatment Note System design may change without prior notification Contact information for customer support Syneron Ltd P O Box 550 Industrial Zone Tavor Building Yokneam Illit 20692 Israel Tel 972 73 244 2200 Website www memyelos com E mail info memyelos com Quick Reference Guide Important safety information Please read all warnings and safety information in user manual before using m my elos Note If you have an active tan do not use m my elos Preparation 1 Clean your skin and wipe the area with a non alcoholic wipe 2 Shave hair in treated area or if you use the shaver or epilator trim hair that is longer than 10 mm you may use the shaver cartridge
9. applicator tip still in one spot When to use m my elos Ramm 1 week 2 weeks aP Afia 3 weeks 4 weeks treatment treatment 5 weeks 6 weeks treatment E 1 perform first 4 treatments every 2 weeks 2 after first 6 weeks use me as hair appears Treatment durations For effective results me my elos should be used according to the following durations X 3 minutes 10 minutes 1 minute 2 minutes When you have finished the treatment 1 Lift the applicator off your skin 2 Press the elos activation button to turn off 3 Press the epilator shaver activation button to turn it off 4 Press the power button on the base unit to turn off the system 5 Place the applicator in its cradle in the base unit 6 Gently rinse your skin with lukewarm water and pat dry 7 Clean the epilator shaver as necessary a gt epilator and shaver gt lt cartridge My 4 elos ivati activation activation T Atan RF d oO livery bars grip sensors www memyelos com Syneron 2010 All rights reserved Syneron the Syneron Logo m my elds and elos are trademarks of Syneron Medical Ltd and may be ae registered in certain jurisdictions elos electro optical synergy isa proprietary technology of Syneron Medical Patent pending PB72932
10. he device again Contact customer service center a lf dropped or damaged DO NOT use the system a Always disconnect the power cord from the wall electrical outlet after use s DO NOT use the system if any of its components show signs of damage s DO NOT open the system s enclosure under any circumstances DO NOT operate the device with a cracked or broken glass window on the elos cartridge To avoid accidents keep the system away from the hair on your head face and also from clothes brushes wires cords laces etc s DO NOT use the system on children or allow children to use this device Keep the system out of the reach of children Adult supervision is recommended for teenagers under the age of 18 s DO NOT use the system if you have limited physical sensory or mental capabilities This does not apply to the latter if they were instructed in the use of the system or if they use it under the supervision of a person responsible for safety Complete power shutdown will be achieved only when the power cord is unplugged EN 5 6 When NOT to use the m my elos system You should NOT use the me my elos system if any of the following items apply to you a lf your skin type is darker than skin type 5 see page 15 a If within the last three days you have had a long skin exposure to the sun or if you have excessively tanned skin from sun tanning beds or tanning creams within the last two weeks as
11. iliarize yourself with this user guide prior to each use of m my elos EN Package contents Upon opening the me my elos package you will find the following components a Base unit and applicator including elos cartridge and epilator shaver protective cap already attached Accessories kit including elos protective cap Electrical power cord User guide including a quick reference guide User guide DVD Warranty card Note Epilator and shaver are sold separately Important safety information Please read all warnings and safety information before using the m my elos system Always follow basic safety precautions when using any electrical product The system is designed for domestic use only Warnings a The system is designed for the removal of human body hair Any other use is expressly prohibited DO NOT use the system for removal of hair on your face or head DO NOT use the me my elos system over tattoos or permanent makeup s During treatment DO NOT hold the applicator tip still in one spot This might cause extensive heat build up and possible skin damage NEVER immerse the system or the applicator tip in water or any other liquid DO NOT rinse any components of the system with any kind of liquid a DO NOT use the system where it can fall or be pulled into water If device is dropped in waiter unplug it immediately DO NOT remove the device from water until unplugged DO NOT use t
12. licator slowly and continuously so the light flashes will follow each other and cover entire area 18 EN DO NOT hold the device in one spot DO NOT treat the face Itis recommended to watch the instructional DVD before using the system for the first time Note When treating curvy areas i e underarm and knees work the area in 2 directions at a 90 degree angle for full coverage Hard to reach areas can also be treated by first using either the shaver or epilator while placing a protective cap instead of the elos cartridge followed by the application of elos while placing a protective cap on the shaver epilator side Note The first time you use the system with the epilator cartridge it may feel slightly unpleasant as you are removing hairs from the follicles This feeling subsides after a few treatments even if you have sensitive skin Important Note The elos cartridge correct position will not operate unless both RF delivery both RF bars are in contact with the skin and delivery bars you are touching both grip sensors on are in contact the applicator with the skin skin surface wrong position skin surface Important Note Do not block or cover the applicator s cooling inlet during operation to avoid overheating of the applicator Please be warned hot air will come out of the hot air outlet once the system is in use cooling inlet e Sa AN a 4 hot air outlet 3 gt
13. los cartridge only For maximum base unit safety it is not recommend to use the elos 6 Gently rinse your skin with lukewarm cartridge more than once every water and pat dry two weeks 7 Gently apply moisturizing cream to Note Results may vary depending on your skin treatment area hair type skin type etc When you have finished the treatment 1 Lift the applicator off your skin 2 Press the elos activation button to turn off Note the cooling vents will continue to work for 4 additional seconds after the elos is turned off 3 Press the epilator shaver activation button to turn it off 4 Press the power button on the base unit to turn off the system EN 21 When you are done a Unplug the system from the electrical wall outlet a Unless elos cartridge is empty do not remove it from the applicator If you remove the cl s cartridge insert the elo s protective cap in place a Clean the epilator shaver cartridge with the cleaning brush supplied s Wipe off the applicator and the glass window of the elos cartridge in particular with soft tissue or non alcoholic wet wipes a Store the applicator back in the base unit a Store system away from the reach of children Important Note To ensure long term performance it is recommended to clean the epilator and or shaver after each use by using a cotton bud which was first soaked in alcohol and then squeezed out The cotton bud must not be soaking wet
14. perfume powder or bath shower oil present on the skin in the area to be treated Before treatment wipe the area with a non alcoholic wipe shaver epilator You can choose one of two options 1 Use the epilator or shaver accessories sold separately simultaneously during treatment with elos In this case there is no need for shaving prior to treatment Note You can use the epilator or shaver if you have hair up to 10mm 2 If you do not use the shaver or epilator accessories you should shave the required area prior the elos treatment Note to ensure best results you should not remove hair by waxing or epilator more than 5 minutes prior to elos treatment Best results are achieved when the epilator or shaver accessories are used simultaneously with elos cooling inlet activation indicators epilator or shaver cartridge sold separately gt J t 7 lt lds y activation Da indicator fo N cartridge lt activation a buttons grip sensors cartridge release buttons 16 EN w i cartridge release buttons elds cartridge Method of operation Select your elds level 1 Select your desired elos level on the system s control panel according to your skin type refer to the table on page 15 Low Medium or High RF delivery bars 7 Treating with epilator or shaver cartridge optional if you choose not to use the epilator shaver you must
15. professional hair removal in the palm of your hand user guide Table of contents About the me my elos hair removal system Package contents Important safety information System description How to prepare the m my elos system for operation System preparation How to replace your elos cartridge Recommended elos levels How to operate the m my elos system me my elos treatment procedure When to use me my elos Troubleshooting Specifications Labels and symbols Detachable Quick Reference Guide About the m my elos hair removal system Your new m my elos system is intended for immediate and long term hair removal The me my elos system is easy to use without assistance and in the convenience of your own home The system is intended for both women and men with Fitzpatrick skin tones l V see page 15 to evaluate whether your skin type can be treated The system is designed for the removal of hair from all body parts below the neck The me my elos system is powered by elos Electro Optical Synergy Syneron s Clinically proven gold standard technology that uses low energy pulsed light together with gentle radio frequency RF Note Hair reduction results may be subject to variation Please read this entire user guide and watch the instructional DVD included before using the system for the first time It is recommended to keep the guide in a safe place for future referrals and to re fam
16. radle Turn on the me my elos device A newelo s cartridge will show 100 on the panel 5 Turn on the elds by pressing the elos button on the side of your applicator Make sure that the elds indicator on the applicator is on and is not blinking 6 Your m my elos device is ready for use Note New elos cartridges may be ordered from point of purchase 14 EN Recommended elds levels Determine your skin type based on the descriptions below and set your me my elos system s elos level accordingly higher efficacy Treatable Skin Tones If using the recommended elos level causes discomfort treat at a lower level lf tolerable increase the elos level for Skin Type 1 Pale white skin always burns does not tan elos Level High Skin Type 2 Fair skin burns easily rarely tans elos Level High Skin Type 3 Darker white skin tans after initial sunburn elos Level High Skin Type 4 Light brown skin burns minimally tans easily elos Level Medium to High Skin Type 5 Brown skin rarely burns tans dark amp easily elos Level Low to High HEN Skin Type 6 Dark brown or black skin never burns dark tan Do not use the m my elds system Note If you have an excessive active tan DO NOT use me my elos EN 15 How to operate the m my elds system Preparation Your skin should be clean before starting the treatment There should be no lotion make up
17. rtridge out and insert the other one in its place Slide the new cartridge into the applicator until you feel it click into place Be Careful The elos cartridge is not interchangeable with the epilator or shaver cartridges bottom side Th i K i 4 YA lt A n epilator or p shaver Cartridge i i 3 i Before use make sure that the RF delivery bars and the light output window on the elos cartridge are clean these may be cleaned using a soft tissue or non alcoholic wet wipes Note The system can be operated just with the elos cartridge shaver epilator protective cap must be attached to applicator s opposite side Note The system can be operated just with the shaver or epilator cartridge protective cap must be attached to applicator s opposite side i Cap EN 11 System preparation The following illustration exhibits the bose unit s control panel and the pages will how to prepare the system for use 12 EN oe 2 Before turning on the system the applicator must be placed in the cradle Press the power button to turn the system on the elos system indicators will flash for several seconds then the indicator next to the power button will turn green Now the system is ready for use into the wall electrical outlet An orange indicator s 1 Connect the power cable into the system and then will appear next to the power button 2j
18. tanning may influence the safety of the treatment alf you have a pacemaker or internal defibrillator a If you have superficial metal or other implants in the desired treatment area alf you have a history of any type of cancer or pre malignant moles m If you suffer from severe conditions such as cardiac disorders a If you have varicose veins in the treatment area a If you have moles large freckles darker pigmented areas scars or birthmarks do not treat over them a If you are pregnant or nursing a lf you have an impaired immune system due to immunosuppressive diseases such as AIDS and HIV or use of immunosuppressive medications EN a lf you have endocrine disorders such as Diabetes or Polycystic Ovary Syndrome a lf you have any active condition in the treatment area such as sores psoriasis eczema burns herpes simplex wounds or a rash a If you have a history of skin disorders abnormal wound healing as well as very dry and fragile skin a If you have a history of bleeding coagulopathies or use of anticoagulants a lf you are using medications herbs food supplements and vitamins known to induce photosensitivity to light exposure at the wavelength used such as Isotretinoin Accutane and or topical retinoids within the last six months Tetracyclines or St John s Wort within the last two weeks a If you are using medications that may stimulate hair growth such as Minoxidil alf you ha
19. ve had any surgical procedure in the treatment area within the last three months or before complete healing a lf you have Epilepsy a If you have applied any type of anesthetics a If you are on gold therapy Note If you are taking any medication please consult with your doctor before using m my elos Possible side effects Removing hair can cause redness or irritation of the skin This is a normal reaction and only lasts a short time Note If sensitivity of area persists longer than 24 hours consult your doctor Improper use of the m my elos system could result in possible side effects Although these effects are rare and expected to clear within a short time it is important to understand that every cosmetic treatment may involve some degree of risk and that you understand and accept the risks and possible complications that can occur with pulsed light combined with RF hair removal systems Side effects may include redness or swelling burns blisters color change or scars This may appear either at the time of treatment or shortly after Note If you encounter any side effects consult your doctor 1 This device is not intended for use by individuals including children whose physical sensory or mental capacities are reduced or who have no experience with the device or do not know how to use it unless they are supervised or have received prior instructions from a person in charge of their safety
20. z Dimensions and weight Temperature 10 C to 30 C a 20 5 x15 x9 cm W xLxH 1 17 Kg Relative Humidity up to 90 at 37 C Altitude up to 3900 m 13 000 ft Note The system will not operate above 30 C 24 EN Labels and symbols Applicable Standards The nameplate label is adhered to the a EN 60335 1 2002 A1 2004 bottom of your m my elos system A2 2009 It displays the manufacturer s name amp address the system s part amp serial Safety Standards numbers electrical requirements and a EN 60335 2 8 regulatory standards that the system is a EN 60335 2 23 2003 designed to comply with a EN 60335 2 27 2003 This table explains the symbols that appear at the bottom of the label EMC Standards EN 61000 6 1 2007 a EN 61000 6 3 2007 Symbol Description A Type BF Equipment mj Class Il equipment CE CE Mark M WEEE Waste Electrical and Electronic Equipment A Attention Consult Accompanying Document EN 25 Copyright 2010 Syneron Medical Ltd All rights reserved Syneron Medical Ltd reserves the right to make changes to its products or specifications to improve performance reliability or manufacturability Information furnished by Syneron Medical Ltd is believed to be accurate and reliable However Syneron Medical Ltd assumes no responsibility for its use No license is granted by its implication or otherwise under any patent or