Home

smok user manual

image

Contents

1. INSTALLATION Install the unit in a well ventilated area Use in an insufficiently ventilated room can lead to the condensation of the smoke fluid The resulting slippery surface can cause accidents Keep a minimum distance of 20cm around the unit Furthermore do not orientate the output nozzle directly in the direction of the audiences eyes In order to create the best effect there should be a distance between the unit and the audience of at least 1 5M Only install the smoke machine on fire resistant scratch resistant and water resistant surfaces DANGER OF FIRE When installing the unit make sure there is no highly flammable material decoration articles etc within a minimum distance of 0 5M Please make sure that the installation angle does not exceed 15 This unit is constructed for a free standing or hanging installation If the unit is to be installed overhead please follow the safety instructions below RIGGING INSTALLATION The installation has to be built and constructed in a way that it can hold 10 times the weight of the unit s to be installed for 1 hour without any deformation The unit must always be secured with a secondary safety attachment e g an appropriate catch net or safety wire The secondary safety attachment must be constructed in a way that no part of the installed unit can fall down if the main attachment fails When rigging derigging or servicing do not allow personnel to be directly underneath
2. e000000 0 0 AMERICAN ARCO www americanpro audio com TF 400 400W TF 900 900W TF 1200 1200W TF 1500 1500W PROFESSIONAL FOG MACHINES WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution e Never remove warning or informative labels from the equipment Do n
3. ght of the unit You must only use safety wires with link screw caps The maximum drop distance must never exceed 20cm A safety wire which has already held the strain of a fallen item or which is defective must not be used again Adjust the desired installation angle via the mounting bracket and tighten the screws DANGER TO LIFE Before operation for the first time the installation has to be approved by an expert OPERATION Switch the unit ON via the power switch Connect the remote control to the Remote Control socket The stand by indicator on the remote control will illuminate After the units warm up time the stand by indicator turns off and the unit is ready for operation Press and hold the button until the desired amount of smoke is emitted If the indicator on the remote illuminates again the unit is re heating no smoke can be produced at this time Please wait until the indicator goes off CLEANING AND MAINTENANCE DANGER TO LIFE Disconnect from the mains before starting maintenance We recommend a frequent cleaning of the unit Please use a soft lint free and moistened cloth Never use alcohol or solvents Clean the output nozzle frequently from smoke fluid residues The smoke fluids we recommend are non hazardous to the environment and can be disposed of via the sewage system There are no serviceable parts inside this unit except for the fuse Maintenance and service operations are only to be carried o
4. ot open the equipment and do not modify the equipment e Only use the equipment indoors Do not expose to flammable sources or gases e Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable e Make sure that the available voltage is between 220v 240v e Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Americanpro dealer for service e Only use fuses of same type and rating e Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS WARRANTY One year from date of purchase OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the p
5. roduct may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property Before filling the unit disconnect the mains Never fill with hot liquids Only use high quality water based smoke fluid recommended by the manufacturer Other smoke fluids may cause clogging and void the guarantee Always make sure there is sufficient smoke fluid in the tank Operating this smoke machine without smoke fluid will cause damage to the pump as well as over heating of the heater Operate the unit only after you have familiarized yourself with its functions Do not permit operation by persons not qualified for operating the unit and always drain the tank and use the original packaging if the unit is to be transported STARTING OPERATION Install the unit on a level surface The fluid tank of the unit needs to be filled with smoke fluid before switching on Always disconnected it from the mains supply as fluid could be spilled Only use quality smoke fluids recommended by your dealer We recommend high quality smoke fluids You must not use substances which are classified as DANGEROUS WORKING MATERIALS or FLAMMABLE FLUIDS If fluid should get inside the main housing disconnect the unit from the mains immediately and consult a technician
6. the unit The operator must always make sure that the safety relating and machine technical installations are approved by an expert before operation for the first time and after any further changes are made The operator has to make sure that the safety relating and machine technical installations are approved by an expert after every four years in the form of an acceptance test The operator has to make sure that the safety relating and machine technical installations are approved by a qualified person once a year PROCEDURE When hanging the unit must not be installed in areas where persons may walk by or be seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including but not limited to calculating working load limits installation materials being used and periodic safety inspection of all installation materials and the unit If you are not qualified do not attempt the installation yourself but instead use a professional structural rigger Improper installation can result in bodily injury and or damage to property The unit has to be installed out of the reach of people CAUTION Units in overhead installations may cause severe injuries when falling If you have doubts concerning the safety of a possible installation do not install the unit Mount the unit with the bracket to your hanging system using an appropriate clamp or bolt For overhead use always install a safety wire which can hold at least 12 times the wei
7. ut by authorized dealers REPLACING THE FUSE Only replace the fuse with a fuse of same type and rating Before replacing the fuse disconnect from the mains Procedure Step 1 Open the fuse holder on the rear panel with a suitable screwdriver Step 2 Remove the old fuse from the fuse holder Step 3 Install the new fuse in the fuse holder Step 4 Replace the fuse holder in the housing Should you need any spare parts only use genuine parts If defective please dispose of the unusable unit in accordance with the current legal regulations Should you have any further questions please contact your dealer TECHNICAL SPECIFICATIONS TF 400 Power supply 240V Weight 2 0Kgs TF 900 TF 1200 TF 1500 Power supply 240V Weight 5 7Kgs www americanpro audio com AMERICAN PRO desarrolla nuevos productos y mejora la calidad de aquellos existentes en forma constante Por tal motivo las especificaciones t cnicas y la informaci n consignada en el presente manual pueden ser modificadas sin previo aviso AMERICAN F gt RCI

Download Pdf Manuals

image

Related Search

Related Contents

Copyright © All rights reserved.
Failed to retrieve file