1. 3 EFES ATRIIS TES LEE ACD InstallShield 18 Select the installation location and 5292299 uF ix click KN Next ee EE TO EE Blo24 4 4 d como Wak RB If you want to change the location click Z ATA i c 0 Nea specify the location and click RAN CXProgram Files NTT DOCOMO dcm_connect_mng EEO ext c InstallShield d 10 Click 4 YA Install B Rat d como
2. FOMA amp Ln FOMA InstallShield Upon confirming the user agreement click Agree to agree to it and click Next lt s oso JU seres jy d como 2 DA
3. same meaning of WPA2 PSk If encryption function is set to the FOMA terminal Co Set Encryption type and Security key options to the same settings as the FOMA terminal 7 Click Close 14 DOCOMO Connection Manager DOCOMO Connection Manager is a useful software for performing the flat rate data communications and the measured rate data communications DOCOMO Connection Manager enables simplification of mopera U subscription or appropriate setting on PC depending on the subscription The fare counter function is also available for checking an indication of the data traffic or usage amount This document describes procedures to install DOCOMO Connection Manager To connect the FOMA terminal to the Internet signing in to the flat rate data plan or FOMA service and the Internet service provider including mopera U is required which supports data communication For more information see DOCOMO website mem wm d FIE Bx 2 ARE X PALTZ ET T docomowi Fi Y l
4. Set up new connection or network Select Setup dial up connection and click RAN Next 32 If the modem selection screen m appears click the in use FOMA Q a scum zamora terminal When connecting wirelessly using Bluetooth communication click the in use Bluetooth linked standard modem or Bluetooth modem provided by a Bluetooth device maker The modem selection screen appears only if there are multiple modems Select the Sr E Phone number for dial up Vie ISP and enter the number of the access point U NTTDOCOMO You can leave user name and password blank for mopera U connection P weveeses To connect to any other provider than mopera U enter the user name and password specified by the provider or network administrator in the REN SAMPLE User Name and Hho d coBEEHESC REIS A Password columns as this screen
5. ISP 4 This screen is an example of accessing mopera U by packet communication 20 Click Connect and then click Skip To confirm the settings cancel a connection test 8 Click EAU Close Click Network and Internet Show network status and task Connect to network on Control Panel Right click the icon created for the dial up and click s Properties ees es VPN SAMPLE SAMPLE2 33 Confirm the settings on the General tab en or more modems are connected to the When connecting using the FOMA USB Cable with Charge Function 02 confirm that only the in use FOMA terminal is checked in the Connection method column When connecting wirelessly using Bluetooth communication confirm that only EZ Ls Modem the name of the in use Bluetooth linked standard modem or Bluetooth modem provided by a Bluetooth device maker is checked in the Connection method column If it is not checked check it Confirm that Use Dial Information is unchecked If not uncheck
6. AARE O 81 SSE 03 Bees P 3815 75 E QU FOMA Ho TCP IP Winsock sample B sample G P TORE D 81 i meee Py RADEN HE EF LOB BS 1 U Enter the access point APN and emen FE FEO A GEO BAD AWW press 4 GE 5505 Enter in the format of AI CGDCONT lt cid gt AT CGDCONT 5 PPP XXX abc PDP type APN cid Enter any number between 5 and 10 Please be cautious because if cid has been already set the setting will be overwritten PDP_type Enter PPP or IP APN Put around the access point APN to enter If OK is displayed the settings for the access point APN are completed Example To enter APN named XXX abc in cid Number5 HA 00100 2400 8 N 1 Enter AT CGDCONT 5 PPP XXX abc 4 Confirm that OK appears and click Close Hyper terminal in the File menu sample Are you going to save the connection samp
7. when you start DOCOMO Connection Manager Mi xm 5 D D mopera U mopera U mopera U O Executing Set Data Communication Start DOCOMO Connection Manager Starting DOCOMO Connection Manager gt p 20 Click the tab of the desired connection method and click Connect For details refer to DOCOMO Connection Manager Help When connection is not available check Setting up Dial up Network p 22 and Setting up Dial up p 30 During packet communication a different icon appears on the FOMA terminal depending on the communication conditions Communicating sending data 4 Communicating receiving data Communicating no data transfer Sending or disconnecting Receiving or disconnecting The icons on the FO
8. InstallShield 3 i T Click Finish fy Installation is completed InstallShield BIE NTT DOCOMO 19 Starting DOCOMO Connection Manager Start DOCOMO Connection Manager Open or Start gt All programs gt NTT DOCOMO gt N DOCOMO Connection Manager gt KIE DOCOMO Connection Manager For Windows 8 click DOCOMO Connection Manager on the Start screen Specify the settings by following i the setting wizard O lt G for the first time Follow the guidance and you can make preparations for Internet connection For details refer to DOCOMO Connection Manager Help The setting wizard will automatically appear 8 mopera U
9. I Wireless network management QU RY H7 ZIMBONER CHOC hP TUM 4d a m omar PC 1 e gri uu BERE P o Click Add Select Set up the network profile manually Enter ESSID for the FOMA terminal in the Q o Network name column set the security type for the FOMA din terminal in the F 4 3 7 XB Security type column and click Next mE G WPA2 WPA2 personal under ROS n Security type has the BE
10. FOMA VO ICHRUT S eeu use OS Turn on the FOMA terminal then connect the FOMA USB Cable with Charge Function 02 optional to your FOMA terminal For connecting the FOMA terminal and FOMA USB Cable with Charge Function 02 refer to the Instruction Manual for the FOMA terminal Connect the FOMA USB Cable with Charge Function 02 to the USB terminal of the PC A message appears on the task bar indicator and then installation starts Click the message and display the progress of installation E E GG f If this screen appears click B Close Installation of the driver is completed when 4 Tc f FOMA F drivers are displayed on the screen Proceed to FOMAR i i War FOMA WC OBEX Port COM4 Checking the installed driver p 1 0 FOMA v Command Port COMS appears on the FOMA terminal display when the FOMA communication setting file is installed on a PC and the PC and the FOMA terminal is connected with the FOMA USB Cable with Charge Function 02 Checking the installed driver Check that the FOMA communication setting file drivers has been correctly installed This section descri
11. A Internet option o Click Connect tab and select x Not dialing exauz 9865 TAEA E51 933 SAMPLE BRE D LCC O WN O O SAMPLE E LAN LAN BA 2 LAN 1 Coo Coe Ga e Click OK Log on as a user who uses DOCOMO Connection Manager When installing DOCOMO Connection Manager be sure to log on as a user with Administrator privilege If you attempt to install the software with another account an error may occur ll For Windows 8 Windows 7 Windows Vista An Administrator account is required If you log on with an account other than Administrator a screen for inputting Administrator name and password appears during installation ll For Windows XP Log on as a user in Administrators group or an Administrator Quit all running
12. Password and JN kkk Confirm Password lt VIN NUN columns as this screen S RAT E P xololokalololokok Click Finish The ue created connection wizard appears ere AL 5 REO 1 GET Upy9 ph Start All programs Accessories gt Communication Network connections 38 Select the icon created for the dial Ez F CE RTV YLT Jp20 up and open 95 0 mw pom 5 Properties in the File menu peus Confirm the settings on the AK General tab 8 OEE If two
13. 84 101 i mode mail Attach file eee eese tete tatnen tainen nate 51 1 re A E E E TA S 53 Bie ae 5l Ll 52 DISCO SAO venia eon bstpra viss tod vpn t EU 52 Receive oi 52 i 53 WON 51 i mode password eere ecce eere eren nennen 38 ION TT 69 Infrared communication eee 77 Initial ZO eio vverctezedes ve bui viU Env oe HY IE YRE VE E YXX d NU PIVIS DIS IUO UE 42 Initial SeEEWIQ uo coin iN Made ve EENUER RS IY d a PETERE IEEE 22 Intellectual property right Copyrights and portrait rights uode 98 Trademarks ur dicitor nara ed D anions 98 International call ecce 44 International roaming eeeeeeeeeeee 48 mulbel4 m 68 do e oI NE T 68 Key operation bo 65 CABE acabo isphteolatene ape tun dtbeti ad 61 Character entry ioannis 31 prs oreinen 27 i mode Full Browser eere 57 MUSIC ME 67 Kisekae To T 36 Koe no Takuhaibin ecce 44 L Lock functio PTT 40 Lock Security Auto key lock sce tror eb riemed 40 BUT fera dE 40 IC card lock cniin eee renner URSUS 40 Omakase LOCK sssisssicssdunssisivnnicssndavisnnssatvvnesexeconsoesvoadevssusens 40 Original LOCK 3 40 Main menu Change main MENU uso n oie WEG RC 27 102 Change menu display ci
14. Add and remove applications Select FOMA model name USB and click Uninstall Change For Windows XP Select FOMA model name USB and click Change and delete When the User Account Control screen appears click Yes for Windows 7 and click Continue for Windows Vista The User Account Control screen is not displayed for Windows 8 and Windows XP Click OK to uninstall To cancel uninstallation click Cancel Click Yes to restart Windows Now the uninstallation is completed If you click No restart Windows manually When FOMA model name USB is not displayed in the Applications and functions on the Windows perform the following procedure Open the model name driver folder created when the FOMA communication setting file drivers is installed For Windows 7 32 bit open model name _driver model name Win7 32 folder For Windows 7 64 bit open model name _driver model name Win7 64 folder For Windows Vista 32 bit open model name driver model name WinVista32 folder For Windows Vista 64 bit open model name driver model name WinVista64 folder For Windows XP open model name driver model name Win XP folder For Windows 8 82 bit open model name
15. Connect to the Internet Select the access point and click RAN Next lh a M Ww SQ C E AJ fs Confirm the settings and click our mx Jb Dial This screen is an example for mopera U connection You can leave user name and password blank for mopera U connection LU CP D 1 Sj M 8 orat m YKD rot 20749 WXB 40 lt The Connecting screen appears gt While this screen appears the log on process such as confirmation of the user name and WW 99oer3it password is performed 3 SAMPLE TRIER Completion of the connection When the connection is complete and a screen indicating the completion of the connection appears click Close Depending on the OS a message appears from the indicator of the taskbar located on the bottom right of the deskto
16. la ss La lt Ss oO Notifying your caller ID on the other party s phone Set whether to show your phone number caller ID on the other party s phone display when making a call Ok TEL function pp Dial Receive setting gt Caller ID notification Activate Deactivate ON or OFF WW Sonet f you hear a message requesting your caller ID make a call again with Caller ID notification enabled or with 186 prefix Ee Checking your own phone number On Profile screen check your phone number own number stored in your miniUIM and model name le gt Profile You can also check your phone number by pressing te gt CO Wit ww Only phone numbers are displayed by default in the Profile screen To save mail address enter directly or obtain from mode automatically as follows On Profile screen Edit Enter your security code Mail address Acquire Automatically Connect to i mode to enter your mail address to Mail address gt field automatically J Finish To change your mail address refer to NTT DOCOMO website Switching between Japanese and English Fe p gt KARE Setting gt Text display input gt Select language A English ed Screen Explanation Viewing display icon Symbols 3 9 etc displayed on the screen are referred to as icons I
17. Click Next Confirm the precautions and click Next r en v D NTT DOCOMO INC as Fre Prem InstallShield E InstallShield R ee SHEA LUE Eko TRE yy ka d como FOMA E
18. Change Network security code J i mode password Bl Default 0000 This password is required to register unregister sites in My Menu to use Message service to subscribe to cancel i mode pay services and to perform other operations You can change the number Via i mode gt English pp Options pp Change i mode Password f PIN1 code PIN2 code lll Default 0000 These codes are set to the miniUIM PIN1 code is a 4 to 8 digit number to prevent unauthorized use of the miniUIM by a third party and must be entered every time you insert the miniUIM into the FOMA terminal or turn on the power PIN2 code is a 4 to 8 digit number that you enter when performing tasks such as resetting total call charges If you enter an incorrect PINT PIN2 code three times in a row the PIN1 PIN2 code is locked and cannot be used any more remaining allowable counts appear on the en After you enter the correct PIN1 PIN2 code the number of times for entry is reset to three You can change the number uy gt Setting P Lock Security pp UIM setting Enter your security code J Change PIN1 code or Change PIN2 code Enter your current PIN code Enter a new PIN code Enter a new PIN code again for confirmation To change the PIN1 code set PIN1 code entry set to ON y PIN unblocking key PUK PIN unblocking key PUK is an 8 digit number used to unlock PIN1 or PIN2 The PIN unblocking key PUK cannot be
19. View connection properties Confirm the settings on the General tab If two or more modems are connected to the PC When connecting using the FOMA USB Cable with Charge Function 02 confirm that only the in use FOMA terminal is checked in the Connect Using column When connecting wirelessly using Bluetooth communication confirm that only Modem the name of the in use Bluetooth linked standard modem or Bluetooth modem provided by a Bluetooth device maker is checked in the Connect Using column If it is not checked check it Confirm that Use Dial Information is unchecked If not uncheck it 31 SAMPLE SAMPLE2 1l SAMPLE se Jue T x4 FOMA wee COM4 Si t7 FOMA COM5 A L O A P QQ 33 N S R OK Click the Network tab and set up each setting ae
20. blue flashes on the display ll To connect to the registered PC Select Accept dialup devices on the FOMA terminal and then perform connection operations on the PC You can also connect the FOMA terminal to the registered PC by selecting Tool P gt Bluetooth Accept registered and confirming Dial up is in standby mode then performing connection operation on the PC 12 Check the modem setting Before setting communication confirm the modem name and the COM port number for the dial up connection Select gt Control Panel For Windows 8 From the Start screen open the Desktop and then move the mouse cursor to the top right corner of the screen to display the Charm Bar Select Settings gt Control Panel For Windows XP Select Start gt Control Panel Open Systems and security in the Control Panel For Windows Vista Open System and maintenance in the Control Panel For Windows XP Click the System icon in Performance and maintenance Select Device Manage
21. 29 Setting up Dial up Q This section takes accessing mopera U by packet communication for example To connect using packet communication enter x 99 3 as the number of access point for mopera U To connect using 64K data communication enter 8701 as the number of access point for mopera U Setting up dial up on Windows 8 From the Start screen open the Desktop and then move the mouse cursor to the top right corner of the screen to display the Charm Bar Select Settings gt Control Panel Select Network and Internet View network status and tasks Click Set up anew connection or network Select Connect to the Internet and click oR Next O Select Dial up and click Next If the modem selection screen appears click the in use FOMA terminal When connecting wirelessly using Bluetooth communication click the in use Bluetooth linked ERR standard modem or Bluetooth modem provided FOMA by a Bluetooth device maker EFL The modem selection screen appears only if there
22. Before using this manual Note that N 01F is referred to as FOMA terminal in this manual This manual uses the default settings and screen shots for WHITE to describe operations To read a screen easily in this manual Stand by display is set to OFF and the font color is black while the background color is white The screens shown as examples in this manual are displayed when English is set for Select language Set English for Select language in advance gt p 23 The images or illustration used in this manual are examples They may differ from the actual displays Unauthorized copying of all or part of this manual is prohibited Contents FOMA Terminal Part Names and Functions Before Using Screen Explanation Character Entry i mode Full Browser i channel Osaifu Keitai i concier Support Appendix Precautions Always follow these directions 7 Waterproof Dustproof Function 16 p Introduction Sound Screen Setting Lock Security Basic Operation Connect p 43 i appli i Widget i motion Movie More Convenient p 70 ee ee ane aye ae el FOMA Terminal N 01F supports W CDMA and GSM GPRS systems FOMA terminals use wireless communications and cannot be used in tunnels underground areas buildings and other areas without reception in outdoor locations with weak reception or outside the service area Reception may also be weak in even some unobstructed upper floors of
23. Bi SSS SS Ce SU TERRE eb St St ae St E SEN Eh rt SE SF el ina Sat LIE Sat RE HS RA CE Ho RE TEE A San RR E 23 AIRE ERES PIE HK kd Sit St 4 1E BH Hd HOO ESE NS ES CS ROS n qi NR c a SS ST a e i nu EE cS Hg T P WB St dd AHS He Sex SES Sur dh d s vA gt amp H l Ui ee on 1 P gt gt Itt Hir gt m uo BRE ESI a Dit gt 3 sl iH 9t XE K BE E fa HE OS EE Ha HER He s i Sd UE sb Eso o GE ka ARA Sb He EE Pee 2H t SE 5 Fa i Si AB Set Sb dz o0 Ko mM qu ME Mb ES EA we iid Tea p e xn En at Ct dt IS SST ET Ss AS NS HE RN SEES RRR MRM Thee De ee Wa SAS OD aA S lal E BRS EEmbRRSREEH en gt ell RS z c eq EHE ad I PESE d NS ent Sat BE SR SE at Se St Sor Sor a tr ao S Scr Sor lel TH s Eil sa SIIR 3th EN EN iili E GS BG 2b a EB ah D a Sd 0 S cH ES SERD R lit tt St Sa D indt ce M Fe na EH AY Ral SAE Dd SEE YS T ER o Sh Se h E oN E S58 ot SBE 1H 3e dp 25 sit db PZN TE Hn i E eg oF qe i jg Ex E A aN GE SLT Sa SE SE NS TD RE AS BE 5 aii OY ST SS SI WA bt TR dE Im cma Te ee Re a ESSE E ab SH ap Fat 8 3 gt Sl MEE Se SS Fin nt Fs SSS Ge SESS EE REE R ch SH SSE SSF a Sa HAH ced SD an SER SS a SN HG SRE ENG SiS HG FE SSE ES tHE IEEE SE SP a
24. Command execution example Only the following 1 pattern can be set This is set to each cid as an initial value Command for requesting a connection at a speed of uplink 5 760kbps and downlink 7 232kbps when cid is 5 AT CGEQREQ 5 OK Saving modem port command setting value The values set by AT commands are initialized every time the power of FOMA terminal is turned on or off except the access point name APN set by AT CGDCONT command p 26 QoS setting by AT CGEQMIN AT CGEQREQ command permit or reject incoming call setting by AT DGAPL AT DGARL AT DGANSM command the setting for specifying sending not sending caller ID of packet communication set by AT DGPIR command and the setting for specifying sending not sending caller ID of 64K data communication set by AT CLIR command However you can save the values set by commands with amp W if you enter AT amp W 4 after the setting In this case other set values with amp W will also be saved These values can be retrieved by entering ATZ 4 even after the power is turned on or off 53 Result codes ll Result codes related with data communication b Ta Character indication Description 0 OK Successfully executed 1 CONNECT Connected 2 RING Incoming call 3 NO CARRIER Line disconnected 4 ERROR Command not acceptable 6 NO DIALTONE Unable to detect dialing tone 7 BUSY
25. Outline Registers a criterion to be used to decide whether or not to allow the QoS quality of service that is informed from the network side when PPP packet communication is established There are 4 setting patterns as described in the following command execution example Though this command is a setting command it will not be recorded in non volatile memory written by amp W nor reset by amp F or Z Format CGEQMIN lt cid gt lt Maximum bitrate UL gt Maximum bitrate DL gt Explanation of the parameters cde 1 10 Maximum bitrate UL gt 2 None initial value or 5 760 Maximum bitrate DL gt 2 None initial value or 7 232 1 cid is a number for managing the access point name APN registered in the FOMA terminal for a packet communication 2 Maximum bitrate UL and Maximum bitrate DL set the maximum communication speed kbps of uplink and downlink between the FOMA terminal and base station When it is set to None initial value all speeds will be permitted but when set to 5 760 or 7 232 a connection at a speed of other values will not be permitted and a packet communication may not be connected Operation performed when the parameter is omitted CGEQMIN Sets the initial value to all cid CGEQMIN cid Sets the specified cid to the initial value CGEQMIN Displays a list of values that can be set CGEQMIN Displays the current setting 52 Command e
26. driver model name Win8 32 folder For Windows 8 64 bit open model name _driver model name Win8 64 folder Double click model name _un exe Itis displayed as model name un depending on the setting of your PC 11 Preparing Bluetooth Communication Perform data communication by connecting a Bluetooth communication compatible PC to the FOMA terminal wirelessly Register and connect the PC to the FOMA terminal To connect a PC to the FOMA terminal for the first time register the PC to the FOMA terminal MENU key Tool Bluetooth Accept dialup devices The FOMA terminal changes to the Bluetooth standby mode and amp J blue appears on the display If no communication is established for about 5 minutes the Bluetooth standby mode is released automatically Search and register the Bluetooth device from the PC Hegister the device from the PC while the FOMA terminal is in Bluetooth standby mode Hefer to the instruction manual of your PC for details on operating it Depending on the instruction manual Search or Search is used instead of Search and Pairing is used Register devices 3 Select YES when the message informing the device registration appears Enter Bluetooth passkey The PC is registered and the PC is connected to the FOMA terminal wirelessly When the connection is established
27. JU Right click the in use FOMA terminal model name and select E Modem setting If the Address information screen is displayed enter Area code and click OK Click the Modem tabto S27 confirm the COM port of the scoves 72 Jae Jg Access point column of the in 2 xocuscar vencosson use FOMA terminal and click OK 2m xx When connecting wirelessly using Bluetooth Crome OM communication confirm the COM port number of the in use Bluetooth linked standard modem or Bluetooth modem provided by a Bluetooth device maker in the Access point column The COM port confirmed here will be used in the access point APN set up p 26 EEDD Cg BUBRCE FOF The contents displayed on the screen and the Se COM port number differ depending on the PC Ee 23 To check the COM port on Windows Vista o Open gt Control Panel Open Hardware and Sound Telephone and modem options in Control Panel If the Address information screen is displayed enter Area code and click OK Click the Modem tab to confirm
28. and foreign patents pending Audyssey Premium Mobile is a trademark of Audyssey Laboratories Audyssey Premium Mobile fixes the audio problems found in mobile phones It corrects the speaker and headphone response problems caused by the enclosure extends the bass to lower frequencies eliminates large volume variations across and within content and allows louder playback by blocking distortion Hyper Clear Voice is manufactured based SfS SRS VIP and the mark are trademarks of SRS Labs Inc licensed complying with GNU General Public License GPL GNU Lesser General Public License LGPL etc For more details see MENU Data box My document ji mode GPL LGPL24 7A About GPL LGPL licenses The first part of GPL LGPL is only available in Japanese 99 The HMM Based Speech Synthesis Engine embedded in this product uses the Simplified BSD License The HMM Based Speech Synthesis System HTS hts_engine API developed by HTS Working Group http hts engine sourceforge net Copyright 2001 2010 Nagoya Institute of Technology Department of Computer Science 2001 2008 Tokyo Institute of Technology Interdisciplinary Graduate School of Science and Engineering All rights reserved Redistribution and use in source and binary forms with or without modification are permitted provided that the following conditions are met Redistributions of source code must retain th
29. C with humidity of 45 to 85 Reception may be affected if you use your FOMA terminal near a land line phone television or radio in use Use the FOMA terminal away from such devices Please keep a separate record of the information you have registered in your FOMA terminal Please be aware that DOCOMO bears no obligation or responsibility in the event that data is altered or lost Do not drop the FOMA terminal or expose it to strong shocks Doing so may cause malfunction or damage When connecting an external device to the external connector terminal earphone microphone terminal do not insert at an angle or pull the cord Doing so may cause malfunction or damage Do not fold the FOMA terminal with the strap pinched between the folding parts Doing so may cause malfunction or damage It is normal for the FOMA terminal to become warm while being used or charged This is not a malfunction Keep using it 13 et ct o a A n 14 e Do not leave the camera exposed to direct sunlight Doing so may discolor or burn the components of the camera Keep the external connector terminal earphone microphone terminal cap closed when not in use Failure to observe this precaution may cause malfunction due to dust or water getting in Do not use FOMA terminal with the back cover removed Doing so may cause the battery pack to fall out or cause malfunction or damage Do not put an extremely thick stic
30. CME ERROR result code is as follows 1 no connection to phone 10 SIM not inserted 15 SIM wrong 16 incorrect password 100 unknown amp F amp W AT CNUM Displays the own number of Result CNUM lt number gt lt type gt AT CNUM the FOMA terminal number phone number type 129 or 145 129 International access code is not included 145 International access code is included CNUM 8190XXXXX XXX 145 OK 45 AT command AT COPS AT CPAS Outline Selects the network operator to connect Displays whether the control signal to the FOMA terminal is available or not Format mode o mode 1 mode 2 Imode 3 mode 4 Parameter description AT COPS lt mode gt 2 lt oper gt automatic searches the network and switches the network operator automatically manual connects to the network operator specified in lt oper gt Disconnects the connection to the network operator Mapping is not performed manual automatic if the connection to the network operator specified in lt oper gt fails works as automatic mode lt oper gt is a hexadecimal value which consists of Country code MCC and Network code MNC The format is as follows Digit 1 of MCC octet 1 bits 1 to 4 Digit 2 of MCC octet 1 bits 5 to 8 Digit 3 of MCC octet 2 bits 1 to 4 Digit 3 of MNC octet 2 bits 5 to 8 Digit 2 of MNC octet 3 bits 5 to 8
31. Ltd Website http www n keitai com lineup sar in Japanese only 1 Technical regulations are defined by the Ministerial Ordinance Related to Radio Law Article 14 2 of Radio Equipment Regulations 2 Regarding the method of measuring SAR when using mobile phones in positions other than against the ear international standards IEC62209 2 were set in March of 2010 The information communication sectional committee of the information communication council partly submitted a report on consultation No 118 in October 2011 for the Japanese technical standard P Radio Frequency RF Signals THIS MODEL PHONE MEETS THE U S GOVERNMENT S REQUIREMENTS FOR EXPOSURE TO RADIO WAVES Your wireless phone contains a radio transmitter and receiver Your phone is designed and manufactured not to exceed the emission limits for exposure to radio frequency RF energy set by the Federal Communications Commission of the U S Government These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies The exposure standard for wireless mobile phones employs a unit of measurement known as the Specific Absorption Rate SAR The SAR limit set by the FCC is 1 6 W kg Tests for SAR are conducted using standard operating positions accepted by the
32. Memo CY DW m So A A a 2 els 3 O a lt D m D lt microSD TEL function Subitem Branch item Data Security Service ife history viewer lt n gJ 0 9 Alc i ajo alol A uo 2 E D ol ENO alc 0 3 zu D Phrases Store wor o 3 3 2 r w D tore word habette Kensaku ontact DOCOMO Search phoneboo dd to phoneboo UIM operation Phone Check d iuo O16 A RIE 23 ele aS F amp c alo C gt lt A 5 o 2 D o O o x gt Forwarding image Rec msg Voice Play Delete msg memo Play Delete VP msg Record message setting nebook Dialed Received Dialed calls call n D ecord voice memo call eceived calls edial uis call blocking Dial Receive setting all rejection set Videophone Visual preference setting set Headset function set otic TEL function Subitem Branch item Videophone Auto redial as voice setting Ntfy switch mode Hands free switch V phone while packet Call duration Call duration charge charge Notify cost limit Reset total Auto reset DisasterVoiceMessaging Koe no Takuhaibin in1 Melody call Voice mail service Other network Call forwarding serv all waiting nglish guidance emote access Multi Number Additional service Choku Den Screen Display Kisekae Tool setting Stand by
33. SF amp W APND 47 AT command Outline Parameter description Command execution example AT CREG27 Specifies whether the result 720 Not informed initial value AT CREG 1 screen is present regarding 7 1 Informed OK the inside outside the Informed when switching between Set to informed service area information Inside the service area and display Outside the service area is AT CREG This setting may not be complete 4CREG 1 0 available depending on AT CREG OK the Operating System Displays the current setting Penn ENVIOS CREG lt gt lt stat gt aren Ae Set valie When you move from stat outside the service area to inside the service O Outside voice call area area 1 Inside voice call area 4 Unknown Testen amp F amp W 5 Inside voice call area AT CUSD Specifies or inquires for the Format AT CUSD lt gt lt str gt 0 AT CUSD 0 XXXXXXXXX network setting regarding OK the additional services n 0 Does not send mid result AT CUSD 1 x 148 k lt m gt lt str gt lt dcs gt initial value 1 0000 0 n 1 Sends mid result lt m gt lt str gt lt dcs gt D US m0 Mid result AON m 0 The settings completed m 1 The EUR requires the AT4CUSD information 4CUSD 0 1 OK str Only 0 9 can be entered Enclose str with double quotation mark amp F amp W AT FCLASS27 Sets the communication 1 0
34. a person may become less than 15 cm such as when you are unable to freely move around set the FOMA terminal to not emit radio waves in advance by i Self mode turning the power off etc Somebody nearby may have an electronic medical device such as an implanted pacemaker or ICD Radio waves from the FOMA terminal can adversely affect the operation of electronic medical devices For use of the FOMA terminal inside medical institutions follow the instructions given at the respective medical institutions Key and battery pack Nylon resin UV coating storage T UV coating Display pane Sub display panel Polycarbonate resin Sub display side panel Polycarbonate resin Tin deposition UV coating Acryli Camera and Infrared data port panel eie Poly catpenate Hard coating composite resin Kes Weweded Aluminum deposition Polycarbonate resin UV E Side keys Pats Maei Ceg Dutersde Polycarbonate resin Back cover Polycarbonate resin Inner side s Silicon rubber External i External connector Polycarbonate resin Polyester UV coatin Um 9 terminal cap thermoplastic elastomer 3 Water stop cen rubber Silicon coating Charging terminal Bass Gold plstin Miei arts Stainless allo Metal parts Nickel platin Storage P y p plating Resin Nylon resin m TUS Battery pack Polycarbonate resi storage microSD card holder Stainless alloy Cover Stainless alloy Cover miniUIM
35. amp zi WW o A ge Use the specified voltage and current Use the AC Adapter for Global use to charge the battery overseas Using the adapters with incorrect voltage may cause fire burns or electric shock AC Adapter AC 100V DC Adapter DC 12V 24V specific to vehicle with negative ground AC Adapter for Global Use AC 100V to 240V household AC outlet only Do If the fuse in the DC adapter blows always replace it with the specified type of fuse Failure to observe this precaution may cause fire burns or electric shock Refer to the respective manuals for the information on the specified fuse e Do Wipe off any dust on the plug Failure to observe this precaution may cause fire burns or electric shock Do When plugging the AC adapter into the power outlet make sure to insert it firmly Failure to observe this precaution may cause fire burns or electric shock Do Always grasp the adapter when unplugging the plug from the power outlet or cigarette lighter socket Do not pull the cord itself Failure to observe this precaution may cause fire burns or electric shock Do When plugging unplugging the adapter into from the FOMA terminal keep it straight and horizontal and do not apply excessive force Failure to observe this precaution may cause fire burns injury or electric shock e Do Unplug the adapter from the power outlet or cigarette lighte
36. ear jen Check only 4 TCP IPv4 Internet Protocol version 4 a si aai ITE TCP IPv4 in the eer 4 TCP IPv4 Use the following items for this Microsoft connection O Microsoft N U Zu tz4 R Click the Options tab and click PPP PPP Settings 15 Clear all the boxes and click OK N M D Click OK Setting up dial up on Windows 7 Select 9 gt Control Panel Select Network and Internet RY Show network status and task Click
37. p 20 is the adapter or cigarette lighter plug correctly plugged into the power outlet or cigarette lighter socket p 21 Are the adapter and the FOMA terminal correctly connected Is the AC adapter optional firmly connected to the FOMA terminal or the provided desktop holder gt p 21 Are the charging terminals of the FOMA terminal soiled when the desktop holder is used When soiled wipe with dry cotton swab gt p 21 The temperature of the FOMA terminal may rise and the charge lamp may turn off with the battery icon flashing if used for a long time while being charged In this case wait for the temperature to go down then charge again gt p 21 Charging may interrupt depending on the usage condition Exit all running functions and then charge again The FOMA terminal becomes hot during operation battery charge During operation during battery charge or if you use i appli or videophone or watch 1Seg programs for a long time while charging the temperature of the FOMA terminal battery pack or adapter may rise There will be no problem with operation Keep using it Battery life is very short Is the FOMA terminal left outside the service area for a long time In a place outside the service area the terminal searches the radio waves for communication and the battery is consumed more quickly The available operating time of the battery pack depends on the conditions of usage and degraded degr
38. the volume of the other party s voice or melody may be decreased sound quality may deteriorate or sound when the camera is functioning may be audible In such a case drain the water to recover the function DOCOMO does not guarantee all operations under actual use conditions Malfunctions deemed to be caused by inappropriate operation by the customer are not covered by the warranty Draining water when the FOMA terminal gets wet When the FOMA terminal gets wet drain the water following the steps below If water adheres to the mouthpiece microphone earpiece or speaker the volume of the other party s voice or melody may be decreased or sound quality may deteriorate In such a case drain the water following the steps below and dry the FOMA terminal in open air to recover the function Wipe the surface of the Securely hold the FOMA Softly press a clean dry cloth FOMA terminal with a terminal and shake it etc on the FOMA terminal to clean dry cloth etc approx 20 times until there wipe off water remaining in is no more water splattering the mouthpiece microphone earpiece speaker keys or hinges Do not wipe off water remaining in gaps directly with a cotton swab etc lt Draining from mouthpiece Draining from microphone or earpiece gt speaker gt Thoroughly wipe off water drained from the FOMA terminal with a clean dry cloth etc Water if any remaining in the FOMA terminal may leak out
39. uncheck it Click the Network FF saMPLE ANN E tab and set up each setting Se 2 y fa Check ony gt X O 4 TCP IPv4 Internet Protocol version D 6 TOP IPvG 4 TCP IPv4 in the C ZOR geld ZR ODIB EL ZEA BO ae A GRAUE Use the following items for this Cs oes Jtr Ms connection Check QoS O Microsoft 9 Z QoS Packet Scheduler and other items if instructed by the provider N UL RO ok ae 12 Click the Options tab and click PPP PPP settings 36 13 Clear all the boxes and click OK es FILCP 3tE CIP abo rPicto ee fee Tin EU omisso UC SUERRU eR IY Tbe D Click OK Setting up dial up on Wind
40. 8 gs n e gem a 855125555 BO xviii AB guvat Fax lt gt Pe If the Address information screen is displayed enter Area code and click OK Click the Modem tab tO confirm the COM port of the scwas mane 45 Access point column of the in Ba Aa Cu use FOMA terminal and click OK a E When connecting wirelessly using Bluetooth communication confirm the COM port number of the in use Bluetooth linked standard modem or Bluetooth modem provided by a Bluetooth device maker in the Access point column The COM port confirmed here will be used in the access point APN set up p 26 Te COM port number differ depending on the PC ok The contents displayed on the screen and the 25 Setting up the access point APN Default setting cid1 mopera net PPP cid2 not set cid3 mopera net IP cid4 mpr ex pkt net PPP cid5 to 10 not set Communication software to enter AT commands is required for the settings This section descr
41. ASS di m M B amp Cha OERI slo gt EY Sa HS SEIN SE C RC 58 DEI a B n fe Pe d de fs IT TERRE HSIEH Sa Eel Gn os rd Et GR Ct MM Es Clit ey che SIE 2188 Ot kim m m uo im co ba HII EUUDEEFPTT T8 3E E UN mie SE e id SYNGE LA EBS H me iun PUSH NES el AF D MERCED MEN I ER qoum z z z S ML SO STUBS UR fis B BERE BE HG E e AG SOL REE HK eH LETC NEREKRULE LRSM BE Zo GM nS SRK SRM MIR eee A ORAL EER E zv BIBT BR TH Hz t SO aS tN AS oa ea TN d SA T GE DE SU HS CEE zo SSB SG BE TE HE GE eS OR a SR Se a A HR GC US I OL GET s S Se T GE a QU BUR QUE TENER BE S o UR A 2 d co SREEMESEEE ER EET BI E S S B RS s RE ER DU EA GEL s HS a UB OK SS BO RB DM RD a GS i MET QN DN ER me E E 3 zuh DERE ES ds RID A SEES ES BER UG SIE BRE RO RE EHI TERI HU TNI IRI SS bis RH Hs GS e IS GS SR ds O Sp po CE MEE IE PERRA KE QM Ad EE Be s ide GS ull REOR EIE UN fee aR ns Bog o N O Bt 66 60 60 60 CD CD CO CO 60 60 CO CO CD CD CO 0D 0D 00 0 CO 60 0 00 gt Fe KORHERR RR HK QUE R OR S RIN REN ARS TSS BY RNS TERROR ARM RSSe Bee OSH HPHRIRHREK BRE HERE ORR OS SR Re RE RIEN SEDENS RB E SRR MEER Da e s ARERMMARS E r 28881 GAARSHE HERSEK PRESSES SHERRI SRS FIRMS SERRE BRR SAD tes 50 SEE HORS HOS ER eee EIS eS SERRA MER MLEME i S SK eee M EE Reni REOR AS BS zio UE RKR RO HRHE RY RES RE Tr eS AEN t uS REGIA MARRE
42. Car Holder 01 Manual 87 Appendix settings are reset to default by Reset settings Some functions that cannot be reset to default settings or default states may be included in settings Mail setting Display setting Signature setting Phrases Store word Mail box lock message Reply format setting Mail Set Emotion Keyword 86 mode web S ppli Menu Search ookmark creen Memo rowsing history i Channel Smode web setting ommon Settings onfirm amp mode setting eset mode setting S pplirun info 8 ppli setting Auto start setting Disp software info overseas use i Widget effect Mainitem Be ppli Ge ppli setting CAMERA TV MUSIC Subitem Branch item ANY Sis vio tls Olu Sjo lt D d heck settings Still image shootin WR Art photo mode ar code reader Medias viewer rogram guide TV timer list imer recording lis ecording result TVlink hannel list hannel setting User setting Qala gt allael Q Oo ct lt S D D gt D 3 te ect C 4 w 3 U MUSIC motion Movie Q DjoLe lt gQ o 2o J amp ojololio AIA nID 1 Sais te lo l3 g es Sema D Q D CY 3 T v or D 5 ont D other files earch all history ar code reader Alarm eceive Ir data chedule
43. Charge Function 02 Stereo Earphone Microphone 01 FOMA Portable Charging Adapter Earphone Plug Adapter 01 01 02 03 Earphone Microphone with Switch In Car Hands Free Kit 01 P001 P002 FOMA In Car Hands Free Cable 01 Stereo Earphone Set P001 Data Communications Adapter NO1 Earphone Plug Adapter P001 FOMA Indoor Booster Antenna Flat plug Earphone Microphone with FOMA Indoor Booster Antenna Stand Type Switch PO1 7 P02 In Car Holder 01 Flat plug Stereo Earphone Set P01 FOMA AC Adapter 01 for Global use Earphone Terminal P001 FOMA DC Adapter 01 02 Bone conduction microphone Earphone Plug Adapter 01 for External receiver 01 connector terminal FOMA USB Cable Desktop Holder N45 FOMA AC Adapter 01 02 4 Battery Pack N30 FOMA Dry Battery Adapter 01 Back Cover N67 Carry Case L 01 FOMAeco Solar Panel 01 Carry Case 02 1 To connect to N 01F the Earphone Plug Adapter P001 or Earphone Plug Adapter 01 for External connector terminal is required 2 To connect to N 01F the Earphone Plug Adapter 01 for External connector terminal is required 3 May not work correctly when connected to a USB HUB 4 Charging with the AC adapter gt p 21 5 To charge N 01F the FOMA In Car Hands Free Cable 01 is required 6 Use in Japan only 7 To attach N 01F to the In Car Holder attach to the 5th position shown in listed in In
44. Digital Television Broadcast Ministry of Internal Affairs and Communications Tel 0120 922 303 From PC _ http www digisuppo jp repack in Japanese only i mode http digisuppo jp m index php in Japanese only ll Battery When you activate 1Seg with the low battery a confirmation screen appears prompting you to select whether or not to activate 1Seg When the battery gets low while watching or recording 1Seg the low battery alarm tone sounds and a confirmation screen appears prompting you to select whether or not to end watching or recording If Rec when low battery is set to ON the low battery alarm tone does not sound while recording When no operation is performed on the confirmation screen for approx 1 minute 1Seg is automatically turned off ll Display when using 1Seg for the first time The disclaimer screen appears When selecting NO on a confirmation screen that is displayed by pressing OK the screen will not appear from the next time Setting channels When you use 1Seg for the first time or move to another area set the channels Q ey gt CAMERA TV MUSIC pp 1Seg Channel setting Auto channel setting YES YES pp Enter title lil To select an area and register a channel list Ww pp CAMERA TV MUSIC pp 1Seg pp Channel setting Select area Select an area or prefecture gt YES Watching 1Seg ied gt CAMERA TV MUSIC gt 1Seg Activate 1Seg Viewing and oper
45. EU requirements for RF exposure The exposure standard for mobile phones employs a unit of measurement known as the Specific Absorption Rate or SAR The SAR limit for mobile phones used by the public is 2 0 watts kilogram W kg averaged over ten grams of tissue recommended by The Council of the European Union The limit incorporates a substantial margin of safety to give additional protection for the public and to account for any variations in measurements Tests for SAR have been conducted using standard operating positions with the phone transmitting at its highest certified power level in all tested frequency bands Although the SAR is determined at the highest certified power level the actual SAR level of the phone while operating can be well below the maximum value This is because the phone is designed to operate at multiple power levels so as to use oo the power required to reach the network In general the closer you are to a base station antenna the lower the power output Z Important Safety Information AN Warning To prevent possible hearing damage do not listen to high volume levels for long periods Export Administration Regulations The product and accessories are subject to the Foreign Exchange and Foreign Trade Control Law and other applicable export import laws and regulations of Japan You shall obtain licenses permissions and consents required thereunder at your own expense and on your own responsibility Fo
46. FCC with the phone transmitting at its highest certified power level in all tested frequency bands Although the SAR is determined at the highest certified power level the actual SAR level of the phone while operating can be well below the maximum value This is because the phone is designed to operate at multiple power levels so as to use only the power required to reach the network In general the closer you are to a wireless base station antenna the lower the output Before a phone model is available for sale to the public it must be tested and certified to the FCC that it does not exceed the limit established by the U S government adopted requirement for safe exposure The tests are performed on position and locations for example at the ear and worn on the body as required by FCC for each model The highest SAR value for this model phone as reported to the FCC when tested for use at the ear is 0 80 W kg and when worn on the body is 0 56 W kg Body worn measurements differ among phone models depending upon available accessories and FCC requirements While there may be differences between the SAR levels of various phones and at various positions they all meet the U S government requirement The FCC has granted an Equipment Authorization for this model phone with all reported SAR levels evaluated as in compliance with the FCC RF exposure guidelines SAR information on this model phone is on file with the FCC and can be found under the Display
47. Grant section at http www fcc gov oet ea fccid after search on FCC ID A98 MDD1075 For body worn operation this phone has been tested and meets the FCC RF exposure guidelines Please use an accessory designated for this product or an accessory which contains no metal and which positions the handset a minimum of 1 5 cm from the body Non compliance with the above restrictions may result in violation of FCC RF Exposure guidelines n the United States the SAR limit for wireless mobile phones used by the public is 1 6 watts kg W kg averaged over one gram of tissue SAR values may vary depending upon national reporting requirements and the network band y FCC Regulations This mobile phone complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This mobile phone has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation 95 This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is oe that interference
48. ISO sensitivity 61 Shooting still images moving pictures y Shooting still images O A gt Frame the shot then Shoot gt Save The image is automatically saved when using Quick Shot AZ Shooting moving pictures O a BEB gt Frame the shot then Record gt To stop shooting Stop gt Save Vw Do not leave the camera lens exposed to direct sunlight Doing so may discolor or burn the components of the camera If the battery is low you may not be able to save still images or moving pictures 62 Viewing still images moving pictures after shooting Still images are saved in My picture and moving pictures are saved in i motion movie under Data box Still images moving pictures can be set to the standby screen etc y Viewing still images moving pictures in Data box Q kw gt Data box My picture or i motion Movie pp Camera gt gt to select the still image moving picture lll To view image while shooting On Photo Movie shooting screen EID Sesion _ To set the shot still image to the standby screen etc do the following On Still image confirmation screen amp Submenu p Set display Select the image to set Shooting On Photo Movie shooting screen Submenu gt Camera mode pp Select the camera mode 63 1Seg 64 Using 1Seg 1Seg service is provided by broadcast
49. Qf p Tool P microSD pp Refer microSD data gt J Submenu gt microSD format Enter your security code gt VES y Viewing data in microSD card lt Example To display phonebook gt eu gt Tool P microSD pp Refer microSD data gt Phonebook Select a file Select data P Copying data to microSD card lt Example To copy a phonebook to the microSD card gt On Phonebook list screen le Submenu Copy data Copy to microSD Select a copying method Metal contacts of the microSD card F Copying data to FOMA terminal lt Example To copy a phonebook to the FOMA terminal gt Ol Tool microSD gt Refer microSD data gt Phonebook Highlight a file pp Submenu gt Add to phone or OVR to phone Select a copying method Enter your security code gt YES hi Backing up data to microSD card Note that if backup data exists in the microSD card the data will be overwritten We gt Tool microSD Backup Restore gt Backup to microSD i Enter your security code gt YES Sending receiving data by infrared communication Exchange data such as phonebook entries and received mail with other devices equipped with the infrared communication Set the other party s device to receiving status You may not be able to transfer data depending on the other party s device This FOMA terminal conforms to the IrMC 1 1 standard ll To
50. RS LINAS S RP 4 SJ ITE ES KRPARLVE MM RNALVMENH IIIC J X LZ23 gt 8 lt 8 max xD lt K y od 9 Eyr SOP SE He HIE SEdC gp A eK Simm ERS MESI ERER BSOIRXSK E NE Kk IRE AHAS 1 ES Ree ERK REE SERRA DO KES PH PERRE SPORE SAR RBI HES AI fe FO Tt SmE NRE DOCE Beas Te me The XT HRERS 28 Ae RSS mE SRR RS oR BRE SH MRLE KOAN Met ee BK Ut GHEN e DIREK MMM SIE mene VERA KEI A EIE SAH AS KER KRH ira nE A HS GP RRM RKKERAERE IADR S DERRER OER Xk AmA 6 Re HE Se HERE NBI 82 QE GA Ne BUEBEHEGIESE BIPmBHRESSSSX CREERSE JER 0 MERKEN SS DIES e F DI EE s PS Oe YS e D SSE HA Ke ne ent s TRAW SREE KOMNSERESGSUNIRSS MEE MEUMUKif TO nnde RAS Ter dier 8 SH te s FE RE WITSRHUUUICISEESUEISI ERIS KRESS ER E EAM HIE R TU HR HN YR DE E 8 x en codes Bi 6 Vl 2H B Ju x OO bk 3E fE NE A E Fourth digit of Kut 0 128 34 5 Eg f E digits of ten codes 377 K First to third u C O CU CO SE SIME ANE RS B AANA SEN E EKE PM HO HE ALORS S28 2E HOSS KREG CREST Heke BPA HER 5 UL a TI mH MEE ES RTI SKANK BME SEE mE Ae RAN uid KKH WEE Bi MERGER TSBHAENPHUSETSEDIS ME Ae RM HISAR BRR RRM WELE p Wi EEKE sy SEHR LEE Sors DOS E PEREKI SERE ESEE MEPS o ERRE nies bin aaa En ARRE IRS PHRHRBRKRIRKREAKR RRR osm KKA MAER Ha PRET TSA wT SHH SOTO ESR OE ER ERER ERERKEN ENR IRIRE ba BE HK LS EXSENRERSU ANIME ISS RAH SR re UE ih Sg oO KARE ES CIB RREA DHH ES fk s NI
51. UNI EEE ES SU BERI PARSER OES HI Aa eA i eene GSES DDR EN eon MER E BH A EK QU oo LO cO Kuten codes aS 3S CO O COOOOO OO OO OO OOOO CO CO
52. after wiping off When charging the battery Accessories and options are not waterproof dustproof Check the following before and after charging Make sure that the FOMA terminal is not wet If the FOMA terminal is wet thoroughly drain the water and wipe off with a clean dry cloth etc before placing it on a provided desktop holder or opening the external connector terminal cap When the external connector terminal cap is opened for charging close the cap securely after charging It is recommended that the desktop holder be used for charging to prevent water from seeping inside and dust from getting in through the external connector terminal Never try to charge the battery pack when the FOMA terminal is wet Donottouch the AC adapter or desktop holder with wet hands Doing so may cause electric shock Use the AC adapter or desktop holder in a place free from water splashes Do not use them in a bathroom shower room kitchen washroom and other places subject to water Otherwise it may cause fire or electric shock 19 s Before Using Attaching miniUIM battery pack Make sure to turn the power off before attaching removing the miniUIM or the battery pack Also keep the FOMA terminal folded and held in your hand The miniUIM is an IC card that contains private information such as your phone number This FOMA terminal only supports the miniUIM If you have a UIM or UIM FOMA card check with a docomo Shop Service Cou
53. allows you to exchange SMS between mobile phones or with subscribers to overseas operators For countries and overseas operators refer to Mobile Phone User s Guide International Services or the DOCOMO International Services website P Sending SMS OM gt Compose new SMS pp Enter each of the lig No address gt and SEN items gt Send Files such as image files cannot be attached to SMS P Checking received SMS Operations to be performed when SMS is received are the same as ones for i mode mail Also the storage capacity and operations to be performed when the storage capacity for received mail becomes full are the same as for i mode mail OW P Inbox gt Selecta folder gt Select an SMS hi Checking new SMS SMS that the FOMA terminal could not receive are stored at the SMS center You can receive the stored SMS by checking with the SMS center OW gt Check new SMS Phonebook Adding phonebook entries FOMA terminal has two types of phonebooks FOMA terminal phonebook that v various functions can be set to and miniUIM phonebook whose entries are available even in another terminal Adding phone numbers mail addresses etc An entry cannot be stored unless you fill in the Name field Q TELfunction pp Phonebook pp Add to phonebook gt Phone or UIM pp Entera name and reading Enter each item then amp Finish hi Adding phonebook entries from redial recei
54. and PC at 460 800bps ll Communication protocol result codes x E Character indication Description 1 PPPoverUD Connected by PPPoverUD BC UDI CBST 116 1 0 3 AV64K Connected by AV Videophone 64K 5 PACKET Connected by Packet The result code appears as character indication default value when ATV command p 51 is set to 77 1 and as number indication when the command is set to 0 Though the communication speed appears in order to maintain a compatibility with the modem connected by traditional RS 232C it differs from the actual connection speed because the FOMA terminal and PC are connected via FOMA USB Cable with Charge Function 02 optional or via Bluetooth Communication RESTRICTION Number indication 100 indicates that the network is congested If this is displayed wait for a while and then try again 54 Result code display example Bl When ATXO is set Regardless of the AT V7 command p 49 setting only CONNECT appears when the connection is completed Character indication example ATD 99 k k x 1 CONNECT Number indication example ATD 99 sk x x 1 1 Bl When ATX1 is set ATX1 ATYVO are set default Displayed in CONNECT rate between the FOMA terminal and the PC format when the connection is completed Character indication example ATD 99 k k x 1 CONNECT 460800 Number indication example ATD 99 x sk x 1 1 21 ATX1 AT V1 are set The following format appears
55. applications Before starting installation quit any Windows software including anti virus Example To close software that resides on task bar right click an icon on the task bar and click Close or Finish 16 Other connection software than DOCOMO Connection Manager DOCOMO Connection Manager provides the same functions as the ones included in other connection software listed below and this is all you need Disable or uninstall the following software if necessary llilSoftware you do not need to use simultaneously mopera U start up tool mopera U connection amp setting tool FOMA PC setting software FOMA byte counter Q Uninstall the following public wireless LAN connection software if docomo Wi Fi is used through DOCOMO Connection Manager The simultaneous use prohibits docomo Wi Fi connection through DOCOMO Connection Manager U public wireless LAN utility software DOCOMO public wireless LAN utility software DOCOMO public wireless LAN utility program Installing DOCOMO Connection Manager Access DOCOMO Connection Manager page on DOCOMO website Access http www nttdocomo co jp support utilization application service connection manager in Japanese only Click Windows e DOCOMO Connection Manager Windows Click Windows FH Download DO
56. at maximum for receiving and 64kbps at maximum for sending outside the FOMA service area and overseas Select IP connection method when you perform packet communication overseas Packet communication using PPP connection is not supported Select PPP connection method when you perform packet communication using Wi Fi connection Packet communication using IP connection is not supported 64K data communication is not available overseas Notice before using Internet service provider fees In addition to FOMA service charges you may need to pay user fees to an Internet service provider to use the Internet These fees must be paid directly to the Internet service provider in addition to service fees of FOMA service Contact your Internet service provider for details DOCOMO Internet connection service mopera U is available mopera U is a pay service for which you need to apply Setting an access point e g Internet service provider Packet communication and 64K data communication use different access points If you are using packet communication use an applicable access point for it if 64K data communication use an access point for FOMA 64K data communication or ISDN synchronized 64K User authorization when accessing network Some access points may require your user authorization ID and password when connecting Use communication software Dial up network to enter your ID and password ID and password will be provid
57. call 55 Kuten Code List HERRE TL fina Be RS R BH CR HI PE ML aS FS Bl ee Be SH toile sd B PH FAK TH E HR SED 4 fae 3 E Ke RS SH Hg ABs SCR BUE RUD d FN Iv fa DI DH E PS B ES tt HS HOS T n EH ds Bin ETE D S e ORI RBS O gt JHH E fs T s D 32 388 co EEN CES GR ia LLL WR EXE HEP LED RIDE CO NAN ED ee OR a a k d o sess ANE EO PSK A E E LR t ss PHS s OSE Be HS I he 88 a cn Hs s c II Re HE E ra ER Sa Fe ES I RS OU ET ete RT SE jg A HE He ka ig IR QN RS FEH REUS s i B BIS C io HI E CT S DITE frr BB RE E TT T n pian Mel DTI ITIN Weste RRR Ha EER REK HKEEk Aa BE RRRA min e BE ANS AE Saar oS eS RO KARSKA HIE BE ANREP GARE RRS H RIO EX K Ux HOR PN LH Re SEK HO XR ESO SSR AS SES ERG SS a SS HR HE aS SS AE OM OS SESS MN RS HO oe OE ES BK UT SISK MME RAE SE ALS Se EL ATER APR NEI ERS RR PERE ih Lt Bee Quz ues mA KKR T TEE o eo Z Kuten Code List Guide to the kuten code table First enter digit 4 then 3 of the kuten code digits 1 Q Some kuten codes in the table here may look different from what actually appear on screens Fourth digit of Kuten cod O 1 y First to third digits of Kuten codes e345 6 7 8 9 o o o E o g 3 x ma o o E o u 0 1 ts of First to third Kuten codes d Fourth digit of Kuten codes 0 1 third s of codes d Kute First t e S gt DAMNE
58. card slot Terminal Phosphor bronze Connector LCP resin Battery terminal Nylon resin Battery terminal connector God pan Battery pack Resin Polycarbonate resin Battery pack N30 a Label PET resin leermalchasss AMSrsn agng ermine ever POM ese N45 ermina resm PPS resin Resin uae a is feet roy et ct o a a Terminal Gold plating Connector 12 General Notes e N 01F is waterproof dustproof however do not allow water to seep in or dust to get in the FOMA terminal Also do not allow accessories and options to get wet or be exposed to dust The battery pack adapter desktop holder and the miniUIM are not waterproof dustproof Do not use them in humid locations such as bathrooms and avoid exposing them to rain If you carry the FOMA terminal close to your skin sweat may cause internal components to corrode and result in malfunction The FOMA terminal cannot be repaired in the following cases the water exposure detection sticker shows water exposure tests determine that corrosion has occurred due to water exposure condensation or perspiration These cases are not covered by the warranty and any repairs that may be possible will be carried out at the subscriber s expense e Wipe with a soft dry cloth such as an eyeglass cleaning cloth Rubbing the display of the FOMA terminal with a dry cloth may scratch the display surface The dis
59. changed If the wrong PIN unblocking key PUK is entered ten times in a row the miniUIM is then completely locked In this case contact a docomo Shop Service Counter lll Notes on the security codes When setting a security code avoid using personal information such as date of birth telephone number street address room number 1111 and 1234 that may be guessed by a third party Keep records of your security codes Keep your security code private If the security code is disclosed to others and abused DOCOMO shall have no liability for any damage due to any unauthorized use of it If you have forgotten your security codes please bring your FOMA terminal miniUIM and official documents that verify your identity such as a driver s license to a docomo Shop Service Counter For details contact General Inquiries on the back cover of this manual Your PIN unblocking key PUK is written on application form copy for customer which a docomo Shop gives you at time of subscription If you have subscribed at a retailer other than the docomo Shop please bring your miniUIM and official documents that verify your identity such as a driver s license to a docomo Shop Service Counter or contact General Inquiries on the back cover of this manual 39 uonejed r1seg Various lock functions You can protect your important information in your FOMA terminal with the following locks TypeofLock Function Setting pr
60. data is only supported initial value AT FCLASS 0 class supported by the OK amp F amp W FOMA terminal AT GCAP Displays the supported area Result GCAP lt area gt lt area gt lt area gt AT GCAP for the AT commands area GCAP CGSM FCL available for the FOMA CGSM Some or all GSM commands ASS W terminal are supported FCLASS FCLASS command is OK supported W W command is supported AT GMI Displays the manufacturer AT GMI name NEC OK AT GMM Displays the FOMA terminal AT GMM product name FOMA model name OK AT GMR Displays the version of the AT GMR FOMA terminal Ver1 00 OK AT IFC Selects the flow control n DCE by DIE AT IFC 2 2 method m DTE by DCE OK O No flow control 1 XON XOFF flow control AT IFC 2 RS CS RTS CTS flow control HFC 2 2 initial value 7 77 22 2 AT IFC Displays the current setting OK AT IFC IFC 0 1 2 0 1 SF amp W OK AT WS46 Displays the wireless 12 GSM GPRS fixed mode AT WS46 communication network of 22 3G fixed mode 25 the FOMA terminal 25 Auto mode OK 48 AT command Outline Parameter description Command execution example AT S Displays the contents of AT S commands and S registers E1 QO V1 X4 amp C1 currently set amp D2 amp SO amp E1 YVO S000 000 S002 043 S003 013 S004 010 S005 008 S006 005 S007 060 5008 2003 S010 001 S030 000 S103 001 S104 001 OK ATXVn Selects the
61. detects water exposure Example the water exposure detection sticker detects water exposure Tests determine that corrosion has occurred due to water exposure condensation perspiration etc or the circuit board has been damaged or altered the external connector terminal earphone microphone terminal display case etc has been damaged These cases are not covered by the warranty and any repairs that may be possible will be carried out at the subscriber s expense After the warranty has expired Repairs can be carried out upon request but at the subscriber s expense Stock period of parts Functional parts required to maintain phone operation will be kept in stock for a minimum of 4 years after the product is discontinued Depending on the malfunction parts shortage and other conditions may mean that the FOMA terminal cannot be repaired 82 Vf Important _ e Do not attempt to modify the FOMA terminal or accessories Requests for repair of the modified FOMA terminal may be rejected The following may be regarded as modifications Putstickers etc on the display or keys Decorate the FOMA terminal using adhesives etc Replace the external parts etc with non DOCOMO components If malfunction or damage occurs as a result of modification charges will apply even if the FOMA terminal is still under warranty Q Do not remove the manufacturer s specification sticker put on the FOMA terminal If the cont
62. different between i mode Browser and Full Browser Site or website displayed using i mode e Submenu Full Browser Switch to FB YES or YES default ll To switch from Full Browser to i mode Browser Site displayed using Full Browser gt kew Submenu pp i mode Browser Switch to i mode Viewing and operating sites D Tab Title of the displayed website if there is no title the URL appears As many tabs as websites displayed simultaneously 2 Scroll bars Current position in the displayed Full Browser page 3 Displayed while connecting to the Internet with Full Browser u Peet ar Next Scroll in the direction that the key is pressed Jump to the previous page Press then amp Page A Page w to scroll up or down f by screen Jump to the next page 57 Storing frequently accessed sites Website displayed using i mode or Full Browser pkey Submenu gt Bookmark Add bookmark OK p Selecta folder gt OK Bl To view bookmarked site ieu gt i mode web pp Bookmark pp Select a folder Select a bookmark Saving site contents Website displayed using i mode or Full Browser te Submenu Screen Memo Save screen memo Select a destination Select a saving method OK YES Shortcut and Disp Shortcut storing methods can only be selected when the storin
63. display and playback are restricted by the miniUIM is set as the standby screen or as a ring tone the default settings apply if the miniUIM is replaced or the power is turned on without the miniUIM inserted li Full Browser Using the Full Browser function you can view websites designed for PCs Note that communications charges may be high if large volumes of data are transmitted by viewing websites containing many image data or downloading files For details on packet communications charges refer to NTT DOCOMO website Upto 1 5 MB per page can be viewed with the Full Browser N only in Japanese m E n Download and save i appli dictionary Deco mail template from the site N of iMenu Select the shortcut icon ij N gt p 30 eee 8 gt MenuList gt access the site Mobile Phone Manufacturer gt N Japanese Browsing i mode site 2 flashes while communicating and flashes while receiving Karen i mode services during i mode 267 T Scroll down to the bottom of the iMenu screen to Connected screen select English Displaying web pages designed for PC O few gt i mode web Full Browser Home Switching Browsers When you switch the browser types note that charge systems are
64. high rise buildings and apartments Please be aware that calls or communications may be disconnected even under optimal conditions when reception is strong and all three antenna icons are displayed and when in a stationary position Athird party may be able to use special equipment to listen in on your calls as FOMA terminals use radio waves However W CDMA and GSM GPRS systems automatically support privacy Ti anu with a scrambling function for all calls to make conversations incomprehensive to third parties FOMA terminals convert voice into digital signals for wireless communications and therefore if you are in an area where radio reception is weak these digital signals may not be properly restored and this may result in distortion of the actual caller s voice Please keep a separate record of the information Phonebook Schedule Memo Record message Voice memo etc you have registered in your FOMA terminal Please be aware that DOCOMO bears no obligation or responsibility in the event that data is altered or lost e It is recommended that you back up important data to a microSD card If you own a PC you can also transfer and save data such as Phonebook Mail or Schedule to your PC using DOCOMO keitai datalink The user hereby agrees that the user shall be solely responsible for the result of the use of SSL TLS Neither DOCOMO nor the certifier as listed herein makes d representation or warranty as for security in the use of SSL T
65. items when the size of 1 track 5 Includes data in the Mail folder in default is calculated as 3 MB 93 Specific absorption rate SAR of mobile phone AZ Specific Absorption Rate SAR of Mobile Phones This model N 01F mobile phone complies with Japanese technical regulations and international guidelines regarding exposure to radio waves This mobile phone was designed in observance of Japanese technical regulations regarding exposure to radio waves and limits to exposure to radio waves recommended by a set of equivalent international guidelines This set of international guidelines was set out by the International Commission on Non lonizing Radiation Protection ICNIRP which is in collaboration with the World Health Organization WHO and the permissible limits include a substantial safety margin designed to assure the safety of all persons regardless of age and health condition The technical regulations and international guidelines set out limits for radio waves as the Specific Absorption Rate or SAR which is the value of absorbed energy in any 10 grams of tissue over a 6 minute period The SAR limit for mobile phones is 2 0 W kg The highest SAR value for this mobile phone when tested for use at the ear is 0 783 W kg There may be slight differences between the SAR levels for each product but they all satisfy the limit The actual SAR of this mobile phone while operating can be well below that indicated above This
66. mopera U Fare counter tes Connection button Use of measured rate data communications Note that the communication charge can become expensive if packet communication is used to communicate large volumes of data such as to view sites and websites containing images or to download data eg applications music movie data or update files for OS or anti virus software Note that data communication with a PC using a USB Cable is out of the FOMA packet flat rate services such as flat rate data plans in Pake Houdai Pake Houdai full Before installing DOCOMO Connection Manager O Operating environment For the PC operating environment to use DOCOMO Connection Manager see Operating environment p 4 For the latest information on the operating environment visit the DOCOMO website Preparation Prepare the FOMA terminal and FOMA USB Cable with Charge Function 02 optional Confirm the price plan discount services and contract details with the Internet Service Provider 15 When the connection software other than DOCOMO Connection Manager is installed disable it if necessary Other connection software than DOCOMO Connection Manager p 17 Setting for Internet Explorer Before installing DOCOMO Connection Manager set the Internet option for connection in Internet Explorer Start Internet Explorer to select Tool
67. response code 1 0 Not use extended result code initial AT VO specification for connecting value OK amp F SW the line n 1 Use extended result code ATA Handles the incoming call RING process according to the ATA mode received by the FOMA CONNECT terminal ATD Handles the automatic AID k 99 k k lt cid gt Packet communication Packet communication calling process for the cid 1 to 10 displays APN with ATD 99 k sk 1 FOMA terminal according to CGDCONT setting CONNECT the specified parameters and dial parameters AT CBST 116 1 0 lt 64K communication gt ATD lt phone number 64K communication AT CBST 116 1 0 OK ATDO90XXXXXXXX CONNECT AT CBST 134 1 0 AV64K communication ATD phone number AV64K AT CBST 134 1 0 communication OK ATDO90XXXXXXXX CONNECT ATEN Selects whether the echo 7 0 Echo back absent ATE1 back is present for DTE in n 1 Echo back present initial value OK amp F amp W the command mode ATH Performs on hook operation n 0 Disconnect the line can be omitted During packet for the FOMA terminal communication OK ATH NO CARRIER ATIN Displays the ID code n 0 Displays NTT DoCoMo ATIO 7 1 Displays the product name same NTT DoCoMo with GMM OK 7 2 Displays the version of the FOMA ATH terminal same with GMR FOMA model name n 3 Displays the each element of ACMP OK signal 7 4 Displays the details of communication functions of t
68. saving battery power Q C5 1 second or longer ll To release the setting 1 second or longer y eco mode autostart eco mode is automatically enabled disabled depending on whether the battery level is higher or lower than the set range Q kw gt Setting Battery eco mode autostart Q ON Battery level pp Select a battery level gt Finish 3 ua am Ss 177 cs oO gt 38 Lock Security Various security codes To make the FOMA terminal more convenient and secure some functions require the security code P Terminal security code ll Default 0000 This security code is required for deleting all data changing settings etc You can change the number ey Setting P Lock Security Change security code Enter your current security code Enter a new 4 to 8 digit security code YES A Network security code ll Any code is set at time of subscription A 4 digit number is required to verify your identity when you subscribe to some services at a docomo Shop docomo Information Center and User support in Japanese only or when you use network services You can change the number Via i mode a gt User support gt Various settings confirm change use gt
69. the other party O Enter the other party s phone number then Koetaku Follow the operation guidance and record a message The other party will be notified that a message is waiting Bi To play a recorded message On the Recording notification SMS detail screen Play YES Also it can be played from gt TEL function pp Koe no Takuhaibin Message confirm voice YES ZA Making an international call Use WORLD CALL to make international calls from Japan ForWORLD CALL please contact General Inquiries on the back cover of this manual 010 Country code gt Area code City code gt The other party s phone number pp voice call 6 V phone O After the call ends x Dial the other party s phone number excluding 0 at the beginning of the area code city code However to make a call to some countries areas such as in Italy 0 is required You can make calls from overseas p 48 Receiving a call videophone call When you receive an incoming call the ring tone sounds and the illumination flashes When you receive an incoming call or V phone Subst You can only receive a videophone call with a substitute image After the call ends 44 Adjusting earpiece volume Q ey gt TEL function gt Dial Receive setting pp In call setting gt Volume pp Adjust with Set S j During a call you can adjust the vo
70. to packet communications charges During international roaming packet communications charges apply both to receive information and to view detailed content Packet communications charges incurred overseas differ from those in Japan e To use i concier overseas overseas use setting for i concier is required Packet communications charges apply to automatically update i schedule Memo ToruCa Phonebook etc e For details on i concier refer to NTT DOCOMO website Receiving information icon When you receive information l appears at the top of the screen On the standby screen gt Select a pop up message Pop up message e e I LJ E h Displaying i concier Butler Sheep key gt i concier NTT DOCOMO 72 oO D om oO E D LI La E Convenient Tools Using Shabette Kensaku Say the keyword in Japanese to use i mode search Ok Tool Shabette Kensaku When using for the first time select Use on the usage guide screen O Within 10 seconds say the keyword into the mouthpiece microphone when the vibrator vibrates and Speak keyword in Japanese appears 9 Fix When silence continues for approximately 2 seconds voice entering automatically ends even if Fix is not pressed and search starts The vibrator vibrates and the i mode search results screen is displayed Speak clearly at natural conversation speed R
71. unit 71 Li n E I CONCcCIer B i concier helps you in your daily life using a character that acts just like a butler concierge The service keeps your data living area memos schedules ToruCa Phonebook etc and information is delivered timely to your mobile phone according to the content of memos and schedules your living area location and interests Information related to the memos schedules and ToDo lists in your FOMA terminal is delivered schedule information and ToruCa in the FOMA terminal are automatically updated to the latest and useful information such as shop hours is automatically added to the Phonebook Also you can share schedules and images in certain groups such as your friends family etc You can easily print Images kept by i concier Machi chara a character on the standby screen gives you i concier information on the standby screen i concier is only available in Japanese ll Notes on using i concier e i concier requires a subscription and is a fee based service i mode subscription is required A noncsubscriber to Data Security Service will be the subscriber to Data Security Service at the same time when subscribing to i concier In addition to i concier monthly charges separate information charges may apply depending on the content information i schedule etc Packet communications charges apply to receive information except some types of information Detailed content will be subject
72. when the connection is completed CONNECT rate between the FOMA terminal and the PC PACKET Connecting party s APN gt lt Upstream the FOMA terminal Wireless base station maximum rate gt lt Downstream the FOMA terminal Wireless base station maximum rate The following sample indicates that a connection is made to mopera net at maximum 5 440kbps for sending and maximum 7 232kbps for receiving Character indication example ATD 99 k x 1 CONNECT 460800 PACKET mopera net 5440 7232 Number indication example ATD 99 x sk x 1 1 21 5 If both ATX1 and AT V1 are set simultaneously a dial up connection may not be correctly made The single setting of ATYVO is recommended List of disconnection reasons ll Packet communication Value Reason 26 Missing or incorrect APN 27 30 Activation rejected by the network 33 Requested service option not subscribed 36 Disconnected successfully ll 64K data communication Value Reason 1 The specified number does not exist 16 Disconnected successfully 17 Cannot communicate because the other party s line is busy 18 Dialed but no response within the specified time 19 Cannot communicate because the other party is ringing 21 The other party has rejected the communication 63 The service or option of the network is not valid 65 A transmission capacity not provided has been specified 88 Sent to a terminal with different terminal attributes or received
73. will not occur ina particular installation if this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Declaration of Conformity Hereby NEC CASIO Mobile Communications Ltd declares that this product is compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC Declaration of Conformity can be found on http www n keitai com lineup index html Japanese only C 0168 This mobile phone complies with the EU requirements for exposure to radio waves Your mobile phone is a radio transceiver designed and manufactured not to exceed the SAR limits for exposure to radio frequency RF energy which SAR value when tested for compliance against the standard was 0 684 W kg While there may be differences between the SAR levels of various phones and at various positions they all meet the
74. without an umbrella in the rain approx 20 mm of rain in an hour Do not attach remove the back cover or do not open close the external connector terminal cap when your hands are wet or when your FOMA terminal has water drops on it You can rinse the FOMA terminal by immersing and slowly moving in tap water of room temperature filled in a bowl or rinse it with hands under light running water from the faucet Rinse the FOMA terminal with the back cover securely attached while covering the external connector terminal cap to prevent it from opening Donotuse a brush sponge soap or detergent for icis Donotapply running water directly to the mouthpiece microphone earpiece or speaker Do not immerse or drop the FOMA terminal in a swimming pool or in the sea If the FOMA terminal comes in contact with any mud or soil rinse it immediately If these dry up and set the dirt would be harder to remove and it may cause scratches and failures Things to keep in mind Before use ensure that you securely close the external connector terminal cap and back cover so that they are completely attached If any fine dirt fine fibers hairs or sands is between the cap cover and the FOMA terminal water or dust could enter the inside of the FOMA terminal Do not spray or immerse the FOMA terminal in liquids other than water of room temperature as illustrated below Example O Q 0 16 Soap Detergent Bath pow
75. 00 a m to 8 00 p m E From land line phones In Japanese only E From DOCOMO mobile phones In Japanese only ere 0120 800 000 toll free No prefix 151 toll free Unavailable from part of IP phones Unavailable from land line phones etc Business hours 24 hours open all year round E From land line phones In Japanese only SI9 0120 800 000 toll free Unavailable from part of IP phones Business hours 9 00 a m to 8 00 p m open all year round Please confirm the phone number before you dial For Applications or Repairs and After Sales Service please contact the above mentioned information center or the docomo Shop etc near you on the NTT DOCOMO website or the i mode site gt NTT DOCOMO website _http www nttdocomo co jp english P i mode site iMenu gt User support gt docomo Shop In Japanese only For loss theft malfunction and inquiries while overseas 24 hour reception E From DOCOMO mobile phones International call access code fer the couniry you stay 81 3 6832 6600 toll free You are charged a call fee to Japan when calling from a land line phone etc If you use N 01F you should dial the number 81 3 6832 6600 to enter press and hold the 0 key for at least one second E From land line phones Universal number gt prefix You might be charged a domestic call fee according to the call rate for th
76. Busy tone detected 8 NO ANSWER Time out in connection completing 100 RESTRICTION Network restricted 101 DELAYED Redialing restricted lll Extended result codes e amp EO RS buds Character indication Description 122 CONNECT 64000 Connected between the FOMA terminal and base station at 64 000bps 125 CONNECT 384000 Connected between the FOMA terminal and base station at 384 000bps 133 CONNECT 3648000 Connected between the FOMA terminal and base station at 3 648 000bps 135 CONNECT 7232000 Connected between the FOMA terminal and base station at 7 232 000bps e amp E1 n ipse Character indication Description 5 CONNECT 1200 Connected between the FOMA terminal and PC at 1 200bps 10 CONNECT 2400 Connected between the FOMA terminal and PC at 2 400bps 11 CONNECT 4800 Connected between the FOMA terminal and PC at 4 800bps 13 CONNECT 7200 Connected between the FOMA terminal and PC at 7 200bps 12 CONNECT 9600 Connected between the FOMA terminal and PC at 9 600bps 15 CONNECT 14400 Connected between the FOMA terminal and PC at 14 400bps 16 CONNECT 19200 Connected between the FOMA terminal and PC at 19 200bps 17 CONNECT 38400 Connected between the FOMA terminal and PC at 38 400bps 18 CONNECT 57600 Connected between the FOMA terminal and PC at 57 600bps 19 CONNECT 115200 Connected between the FOMA terminal and PC at 115 200bps 20 CONNECT 230400 Connected between the FOMA terminal and PC at 230 400bps 21 CONNECT 460800 Connected between the FOMA terminal
77. COMO Connection Manager for Windows Upon confirming the user agreement click Agree of Download to agree it litte File Download Security Warning screen appears Click Execute Execute the downloaded file and when the User Account Control screen appears click Yes for Windows 8 and Windows 7 and click Continue for Windows Vista For Windows XP the User Account Control screen is not displayed Setup program starts immediately For Windows 8 9 NTT DOCOMO INC D oe u N or 17 For Windows 7 For Windows Vista NTT DOCOMO INC v D
78. FOMA Power outlet terminal in direction D and securely attach it s Charge lamp Take care not to pinch the strap etc when attaching it Plug When charging is complete the FOMA terminal can be removed by simultaneously holding down the desktop holder and lifting up the FOMA terminal FOMA AC Adapter 01 02 hi Charging using AC adapter Open the external connector terminal cap of the FOMA terminal p 17 then plug the AC adapter connector horizontally facing the face with the engraved mark up into the FOMA terminal s external connector terminal O Plug the AC adapter into the outlet When charging is complete remove the AC 4 P lt adapter connector horizontally from the FOMA ac Adapter Release terminal while pressing the release buttons then 01 02 buttons di S dei unplug the AC adapter from the outlet 21 Turning power ON Configuring default setting 1 second or longer ll If Initial setting screen appears When you turn the power on for the first time after purchase Initial setting screen appears If you select YES screens for initial settings such as Auto time Change security code and Keypad sound appear ll To turn the power off Press for 2 seconds or longer 10 For the initial settings you can also set the time difference adjustment and character size After you set all functions Initial setting screen will no longer appear at power on oo
79. FOMA terminal with water drops In cold places water may freeze and cause malfunction To prevent condensation do not transport the FOMA terminal from a cold place to a warm place without allowing the FOMA terminal to reach room temperature Do not apply water flow stronger than allowed gt p 16 e g such water flow that gives you pain when applied to your skin directly from a faucet or shower head Doing so may cause malfunction though N 01F is waterproof to IPX5 standard Do not wash the FOMA terminal in a washing machine etc Accessories and options are not waterproof dustproof When watching 1Seg etc with the FOMA terminal attached to the provided desktop holder do not use it in a bathroom shower room kitchen or washroom even if it is not connected to the AC adapter Donot put the FOMA terminal in hot water use it in a sauna or apply hot air flow from a hair dryer etc to it Do not poke the mouthpiece microphone earpiece or speaker with cotton swabs or sharp objects The waterproof dustproof function may deteriorate Do not leave the FOMA terminal wet Doing so may cause short circuit of the supply terminal The FOMA terminal does not float on water Do not drop the FOMA terminal Scratches caused by dropping may result in deterioration of waterproof dustproof function Do not leave water on the mouthpiece microphone earpiece or speaker If water adheres to the FOMA terminal
80. I PUE REL SR D Ree e EXSERNSRY 52 Deco mail pictogram Deco mail picture 32 Decome AnllYiB score eacus tip ive ees on cos cxi bul eeu 52 Desktop holder rrt peat Fav toa opo EVE EY Er eV ra ea0 21 Desktop ICODaienkvr xvi E DER PP 25 40 docomo Palette Ul soeoesssoososssssoossssssssossssssssose 29 Download AMOU ON acesse ircen it een ene ee eee eee ee ee 69 PB o AE RAET E R REE E EO 68 MOViE TERNI RR P EDAM REOR 69 Widget Appli POM M 68 Early warning Area Mail eres 53 CC TIVO io divinse seed sede 37 Error info send set eee eere nennen 83 Export Administration Regulations 97 FeliCa SNHUNKGI Be 71 Full Browser Booktnatk s reme treat etes tentma Ep br epu N 58 Screen mYettiO meos niens tivo t ad ES 58 Viewing Operating sites eres 57 OO 30 Handling precautions cccssccssscsscsssscssscsssseees 13 Handling the FOMA terminal 7 IC card LOCK ssi ossciesveseneveincivounes essed 40 IC transmission sesscisstececssssssecsesscecssosecasecsososvosesscesses 78 BMB 59 Icon descriptlOTL uiuere era eie p One har rra iri Fn CA 24 SOCIO PETERE ET 72 uminatio MR RET 36 PHN GG nene EE eee 56 Display i mode Stel asa ierat eas tre iEb boi perE t 57 Screen MEMO ocaciresssicasnainstecsvatrenacavecte betaativiR On ERR siasi 58 i mode fault diagnosis site
81. LS In the event that the user shall sustain damage or loss due to the use of SSL TLS neither DOCOMO nor the certifier shall be responsible for any damage or loss Certifier VeriSign Japan K K Cybertrust Japan Co Ltd GlobalSign K K EMC Japan Corp SECOM Trust Systems Co Ltd Comodo CA Ltd Entrust Limited and Go Daddy Group Inc This FOMA terminal is available for use in the FOMA Plus Area and FOMA HIGH SPEED area The display is manufactured using high precision technology but there may be some dots that fail ra light or remain permanently lit Please note that this is a characteristic of displays and not a malfunction Part Names and Functions lt Using Earphone gt Connect an external connector terminal compatible earphone optional To use an incompatible earphone connect an adapter converter optional Ke T o The 1Seg antenna is built in and the FOMA terminal itself works as an antenna The AC adapter for charging and the Stereo Earphone Microphone 01 earphone microphone terminal use the same slot Stereo Earphone Microphone 01 i Jii D AC adapter et ct o a A Earpiece Hear other party s voice from here O Display llluminance sensor Detect brightness Do not cover with hand or put sticker on it Multi function keys 5 9 Up Down key Move the cursor or contents etc upward o
82. M lock removal refer to NTT DOCOMO website PG AOA CEN TT M 21 Adapter ssinncstatiuatdtsrcenairinsasentucdveisbietsmontacvestelasendareas 9 After Sales Service eesseescescesccescescescssscescesceseceseese 82 IGE PE vnte pi m mon an HII TE 74 Area Malls nv po ERR EERNTRMI IS Ko Citer PAYER HE 53 Auto receive Mail scoseesteststenvesirecue ries phan rut rss 52 Auto key lock eise tese riner enti Pro REX Fevrier ds 40 BACKING sch sccses vobaccencepesavasapasdesesveiassiundeesstarsedeyscuesens 34 Bar code reader eessesseescescescesscescescesscescescescesseeseeo 74 Battery level iicaeiseivt er re REN SER SR OXEA SEXE PERIERE eUE 24 Battery pack A 20 Handlin goa 8 Bookmark sisesssascecsseceteceaseniesrnssevdvouivenseiemssesbseasvevenivds 58 Call OWN 47 Call rejection set LLL er rr YES repa EYE 41 s BUrpIinMe 47 Caller ID NOUR CATIONS ucsssesssisetettneee res poxn bx rures 22 Camera Shoot moving pictures ooo viv trn nad s 62 Shoot still ITIQO Saca pois prendi es 62 Change Machi chara eere sss ees 35 Character QIN Ys usn epos rer Een ex Fe up YER TENE 31 Character S126 noi RO XRSINI YEA VIRA nO RV NH 35 Charge 21 Charge about waterproof dustproof 19 Check with the illumination 37 Check your own phone number 23 Conri ct to PE Skate22eeexe 78 D co mall a spessore ether en SP
83. MA terminal display may differ depending on the model For details refer to the Instruction Manual for the FOMA terminal When executing data communication by using the FOMA USB Cable with Charge Function 02 optional to connect the PC to another FOMA terminal the FOMA communication setting file drivers must be installed again 20 How to disconnect Just closing the browser or mailer on your PC does not disconnect the communication line When you do not perform data communication be sure to disconnect by the following procedure Click Disconnect on the DOCOMO Connection Manager screen 2 Click OK RE X He D mopera U 222 785K Cf F 1 741 7 F 146A 3627 e With Windows OS software will be automatically updated if set to do so and you may incur high packet communications charges without knowing you are doing so The communication speed displayed on the PC may be different from the actual communication speed 21 Setting up Dial up Network This section describes how to set
84. MH GAARA BE HO REA LO RODo ANTO ORDA Qoo CJ QU QJ QU QU QU QU QU QU QJ QU CU SHH SS K EK EKI LS hk PREKIN SRAM SEBS EET KERRE MARE KARE SIR ih aS 121k KL ako EXRANESKE AE 00 QI C sf LO CO CJ QJ QJ a CM CU cw QI QJ We THIKI AIEO DIT E rx Hu B HH HA fo Rd e HH ue MELIORI SABE SA GK MER SS Rte E L IN Ht SES SS BH HR IR HE EX BS EK cr rs HS d RID ed Rk Ho E se ami SR AS HO H IHRE ETE J We FR ES 48 FF 244 dd Ml CE GN Gem c3 EI eu OO9 VI 5t AX A Ow V 4 s dy nI e I pK C choi WHERE ERKA awg xy HEHRK R LE E Do BERG RS BoD amp 4r OO DL amp A2 g DL WUO gt OES gt In i ES E HOP BES sr ET eS DM p eH PH LN DIS ag a SAREN EEN HIK LIIN KI H BO KDP LH icd pO eq iS fO e PR INV for NGAR qu FAR ASR HRI 3 SE MOR EAs i TK iis EN RR HR et oo Ea KANKRE ND HD HA PAZ FO DOKANCWPASD DAK ANDAKAR 283K RS tH HK EDEN SS ETE HR e B OR S xa RS 9t ea eb RE Ic WR HK RS EN EUER eg ICE SR IS SES Baw eod 4 5 6 7 8 9 H OF HO lt I X SSO o N N HA T AN Al 8 COP css VANK 1 4 O QI CD 5f 10 OR 00 O T us d SWOWRSENO 532101215 61 0 2 18 TU 3 F9 2 116 L6 iy I8 T 423 5 16 Ne Q FJ N 3 VET STATS 2D NEAN
85. NTT docomo N 01F INSTRUCTION MANUAL 13 11 Thank you for choosing N 01F Before use be sure to thoroughly read this manual to ensure that you use N 01F correctly About manual of N 01F The operations of N 01F are also described in Guide available in this FOMA terminal and Instruction Manual Detailed version Japanese PDF file other than this manual Z INSTRUCTION MANUAL this manual Provides information about screens and basic operations E Guide available in this FOMA terminal Provides information about the outline of frequently used functions and of operations in Japanese only On the N 01F standby screen leM b Tool Guide Guide is not available when English is set for Select language B Instruction Manual Detailed version Japanese Provides detailed information about all functions and operations From PC Download from NTT DOCOMO S website http www nttdocomo co jp support trouble manual download index html TheURL and content may change without prior notice Accessories and major optional extras gt L lt N 01F including written Back Cover N67 N 01F INSTRUCTION MANUAL Battery PackN30 Desktop Holder N45 warranty Japanese E Basic package ll Options and accessories compatible with this FOMA terminal gt p 87
86. New mail Shortcut icons examples GO 01 E 01 Eg Msg f i concier ma a Guide Japanese i concier dv J9h Guide Voice quick start Medias viewer D n i Sion To select a desktop icon or shortcut icon to launch a function on the standby screen gt e Viewing sub display On the sub display incoming call mail or alarm notifications appear with various messages images or animations ll Example Clock Digital 1 yum call New mail 25 t oO Ss cD w oO 5 P Checking missed calls new mail ll Checking missed calls Press la to view received date time caller s name phone number etc ll Checking new mail Press 4 to view sender received date and time subject etc You need to set Mail under Sub display setting to ON Missed calls 12 19 Thu 12 05 Wn Setting pp Screen Display Sub display setting ON P Mail gt ON b Finish Viewing main menu You can select various functions of the FOMA terminal from the main menu The main menu here is in Standard eo mm Mail 4 Gal m CAMERA TV MUSIC y 778 eh TEL function 2 z 3 ip KX mode web DDli 2 5 IPEICW d Tool 8 9 Fa Map Setting Overseas a i concier 0 gn p E Osaifu Keitai Prof
87. ON initial value AT amp SO signal to be output to DTE 1 DR signal is ON when the line is OK connected when the communication amp F SW call is established 42 AT command Outline Parameter description Command execution example AT amp Wn Stores the current settings Only 7 0 can be specified can be omitted AT amp WO OK AT amp W OK AT amp W ERROR AT amp W ERROR AT DANTE Displays the FOMA terminal O FOMA terminal signal reception level is displayed as AT DANTE signal reception level out of area DANTE 3 1 FOMA terminal signal reception level is Oor 1 OK bar 2 FOMA terminal signal reception level is 2 bars AT x DANTE 3 FOMA terminal signal reception level is 3 bars DANTE 0 3 OK AT DGANSM 77 Sets the reject permit mode 7 0 Disables the incoming call reject AT AT DGANSM 0 setting for the packet DGARL permit setting AT DGAPL initial OK incoming call This value AT DGANSM command is effective for n 1 Enables the incoming call reject DGANSM O those incoming packet calls setting OK US 7 2 Enables the incoming call permit input setting AT DGANSM Displays the current setting AT DGAPL 7 cid Sets APN which permits 7 0 Adds the APN defined by cid to AT DGAPL 0 5 incoming packet calls by incoming call permission list OK using lt cid gt parameter 7 1 Deletes the APN defined by cid A
88. PIN2 TGPIN SIM PIN is ct a Cannot enter the PUK1 or PUK2 AT CPIN 1234 code OK CPIN SIM PIN PIN1 entry standby The status in which CPIN SIM PIN2 PIN2 entry 4CPIN SIM PUK is standby answered when CPIN SIM PUK PIN1 blocked 4 CPIN is entered Can enter PUK1 code PIN1 lock status CPIN SIM PUK2 PIN2 blocked AT CPIN 12345678 Can enter PUK2 code 4934 The command displayed on the right Ok is an entry sample of PIN code 1234 and PUK code 12345678 The status in which CPIN SIM PUK2 is answered when CPIN is entered PIN2 lock status AT CPIN 12345678 1234 OK AT CPIN CPIN READY OK AT CPIN OK AT CR N When the line is connected 7 0 Not display initial value AT CR 1 displays the bearer service 7 1 Display OK type before the CONNECT lt serv gt Displays only GPRS which means ATD 99 sk sk ok 1 result code is displayed packet communication CR GPRS Displaying SYNC or AV64K CONNECT depending on the line type AT CR amp F amp W Displays the current setting AT CRC 27 Sets whether to use the 7 0 Not use CRING initial value AT CRC 0 extended result code for the n 1 Use CRING lt type gt OK incoming call Format of CRING AT CRC CRING SYNC CRC 0 CRING AV64K GPRS PPP zAPN PPPoverUD received AT CRC CRING SYNC Displays the current setting ee CRING AV64K PPP packet received CRING GPRS PPP
89. Public mode when you are E Driving Using a handheld mobile phone while driving will result in a penalty Exceptions are made in case of emergency such as to safeguard injured persons or to maintain public safety Bl Inplaces such as theaters cinemas and art galleries Respect privacy Please be considerate of the privacy of individuals around you when taking and sending photos using camera equipped mobile phones 2 What DOCOMO does to be eco friendl gt Slimming down the manual By describing only basic functions and operations we have succeeded in reducing paper usage and slimming down the Japanese instruction manual For further explanations see your F Guide Japanese available in your FOMA terminal or visit NTT DOCOMO s websites Collecting and recycling of mobile phones ffi We collect your unnecessary mobile phones and other devices irrespective II Of carrier Bring them to a docomo Shop near you Intended devices Mobile phone PHS battery pack charger and desktop holder irrespective of carrier General Inquiries i i Repairs lt docomo information Center gt eje 0120 005 250 toll free E From DOCOMO mobile phones In Japanese only Service available in English Portuguese Chinese Spanish E No prefix 113 toll free Unavailable from part of IP phones Unavailable from land line phones etc Business hours 9
90. Result CPAS pas 0 FOMA terminal can send receive control signal 1 FOMA terminal can not send receive control signal 2 Unknown control signal sending receiving is not assured 3 FOMA terminal can send receive control signal and it is currently receiving 4 FOMA terminal can send receive control signal and it is currently communicating Command execution example AT COPS 0 OK AT COPS COPS 0 OK AT COPS COPS 2 44F001 3 44F002 0 1 3 2 OK AT CPAS CPAS 0 OK AT CPAS ERROR AT CPAS CPAS 0 4 46 AT command Outline Parameter description Command execution example AT CPIN Enters the PIN code in the Format AT CPIN lt pin gt lt newpin gt The status in which FOMA terminal This command is to enter the PIN1 CPIN READY is PIN2 or PUK code depending on answered when the state of the result code returned CPIN is entered when AT CPIN is entered of the AT OPIN 1234 FOMA terminal ERROR Even i PIN code entry or the PUK The status in which code is requested on the screen CPIN READY is depending on the state of the result answered when code when AT CPIN is entered you CPIN is entered may not be able to use this command AT CPIN 12345678 to enter the PIN Do not use this 1234 command to change PIN code Put ERROR pin and lt newpin gt in AT CPIN result The status in which CPIN READY PIN1 code
91. SP This screen is an example of accessing mopera U by packet communication mS Click Connect and then click Skip To confirm the settings cancel a connection test Click Set up the connection and then Close 8 Open O Access point 35 Right click the icon created for the dial up and click Properties Nu SAMPLE Confirm the settings on the Z smeren General tab If ir or more modems are connected to the EE P When connecting using the FOMA USB Cable with Charge Function 02 confirm that only the in use FOMA terminal is checked in the Connection method column When connecting wirelessly using Bluetooth communication confirm that only CP Modem the name of the in use Bluetooth TOFIA EDRN linked standard modem or Bluetooth modem provided by a Bluetooth device maker is checked in the Connection method column If it is not checked check it Confirm that Use Dial Information is unchecked If not
92. SR RS RUS Sets debe SY nie HE H HO HK HARES c Hr AV MR 3 MI RR cs 0 Lj SS MS SS SH DS IRE TEE RS TS a LL SS NRI E cu 83 5 Ch HIT 4 HEN T HER HE OK HESH NT RR E Ml 8 RS PR ER KEI SS Ds T HE on SE R RE T RE is i EE FRE ab Gel AN SS EC D Ee SS ie ES ER ES S ROB HET RA REI ES PI o ts Rd GS D s SE SE e fes RTH ES NE HU ROS HS 1K HES HR ME LCS ME x VET T SS E E R A SEE RE E BUR oN HE HS SGT D ed RO RS IE RD D ca HY A ER SOS S e RE a s x HD 99 I Br PG e HG Ss SS Mi tildiurEME IIIS EL ui EIE ax zu SN x gm TR eee pun PCA MEOH ROERE EUERE PEKCAN SEHK ESO OITS BARENE SOHN MENT SWARMS HEMKLESKE AEE MERTEN MERMERE HARER SE SE SE SE BS ce oo DRS NRERMIEE Rema BSR RHEL BEERS RENS NSSH Sees Er Bn Oe ER gt Fourth digit of Kuten codes dits of 0 2 3 4 5 6 8 9 kiten codes SE Cease DORESESURSISSESSSIS BEER He eRe EIC MER SO SE EMS SREE SI SR zl ig SE S St EST UP ER E RAR n RR os HS ol EG CE NT BT IR PEE SS MN ED RR NS ESL Sh DR SK e EE BLESS Ho I ee DE SE if RI RE e RR i AM BA SHR SS Ee se xd SES ERES SEE IRE SON T T d BR DEED ae SS e M EH HB DRE Tu ET SS SH Rs Es id EP BT I E e e M OTT UR EET E D BS FR Te TO LOT RE GEE Mog ts ER ERE ES ERSTE C E e al B SK LE SE RS Sae 208 SU SEE OS E ND HHE RN i HR A EK HEUS ES INI S m ED Fs i ME B ERI E URL IR B E EST ED 68 DER MT CS RES A FE PRX E LS AR a US A EE R sm SE E SAE Rie SE INE E NOE BE DIL HR IR TE e IRI Se AE SUE RE ES E T T e Nis ES
93. Select an item 34 hi Making display hard to see from people around Privacy angle makes it difficult for others to see the display When Privacy angle is set is displayed on the standby screen Q8 1 second or longer ll To release the setting 1 second or longer i E may not be able to set release the Privacy angle while editing a text etc hi Changing menu display Ok Setting Screen Display Menu display set Select an item y Changing font settings On the standby screen 1 second or longer gt Selectfont pp Selecta folder Select an item font then Set Select the thickness in Thickness Select a character size in Character size hi Changing Machi chara setting Set Machi chara and a character appears on the standby screen to inform you of i concier information missed call new mail unread mail etc f gt Setting gt Screen Display gt Machi chara setting gt Display setting P ON Select a Machi chara pp 4 Set ae ae and Machi chara cannot be set to the standby screen at the same time 35 Setting Kisekae Tool Set various FOMA terminal designs such as screens and ring tones at once Q kw gt Setting Screen Display Kisekae Tool setting Select a folder O Highlight an item pp 6 Set all p YES 10 nt oma When you use Kisekae Tool to change the menu display design the structures of so
94. T DGAPL defined by from incoming call permission list DGAPL 1 CGDCONT If cid is omitted this will apply to alll cid OK AT DGAPL n occ cM Displays incoming call permission list p AT DGAPL OK AT DGARL 7Z cid Sets APN which rejects 7 0 Adds the APN defined by cid to AT DGARL 20 5 incoming packet calls by incoming call rejection list OK using cid parameter 7 1 Deletes the APN defined by cid AT DGARL defined by from incoming call rejection list DGARL 1 CGDCONT If cid is omitted this will apply to alll cid OK AT DGARL cel Displays incoming call rejection list r AT DGARL OK AT DGPIR27 This command validates the 720 Uses APN as it is initial value AT DGPIR 0 setting for notifying Caller ID n 1 Uses APN by adding 184 Caller ID OK when sending receiving is always not sent AT DGPIR packet communication n 2 Uses APN by adding 186 Caller ID DGPIR O Even in the dial up network is always sent OK setting you can also add AT DGPIR uo R Displays the current setting number p 28 AT DRPW Displays the indicator value AT DRPW of the receiving power of the DRPW O FOMA terminal OK AT DRPW DRPW 0 75 OK AT CAOC Inquires for the current AT CAOC charge CAOC 00001 4 OK 43 AT command Outline Parameter description Command execution example AT CBC Displays the battery sta
95. TE mu EMI RU RS aN A I SB Se E fee Ke MEEK MESIRE Reanim WES Dea SSL BRS ee PAH Se SRR SRO BRRR K SSH RRE ase CU St CU CO m m C C CO n 8 9 Z0 m 8 Qu LL Oo First to third digi Kuten codes O st LO C C 333 TS 00 CU O IE 8I TRON ME LP RS EE SMS BK EBD UE Ee L IS 8E Make RS R Res MUIR BOR SK hind E SMR WPIDEXEM ES PERS WA HAR SEAVER GT SRB ARN AREA CODA IR DA EE COMO Ht manie THAR RSS sc MUHSBRCSHEZPARESS xDD HER HR KSEE SKE MRE RCIA BRP PE A EAC HON NO S Hk Ea BSW BR RK RRM LAR Ee ERE SLA FS KU EK Oe HE IRE TR NER SSS SE EHARA AH SRR BAR DP EHE Hb EIE Eo 8 EP CTS ES H f s RO Ha eS s E VIT SE n PMA TENE SEZHBERE ID ECEREE UE SRS BE HESS ETUR DTI AES is tf AILES Ez UIN rs TSR UL He CE f BT e PAER EE pe MK a al oA HA CL Wh SS Ha eR A UR A eR ID E RRR KEN RR RAM FS S8 RS BAT LE LE BP S BS ILE HEK AK ES Be ae AKIE SS RRR RIVONIA K OKRA CHEEKS PA RS INTE S E ES MS DL S SE SIT S S RS rt p I ROI TRI SUITS Wino SA Haase ee OME ORR Vee T ln fe LG SN by CU cu IO CO e o 5 Dla A ds LS sp 2 de EE BH A ASHAMED U Ls HRK avo LEX 346 at Hi AE Fh RHEE SE st LO CU LO LO a QU CU z ao TEM a7 e o fiio 23 GERE CEEE Ek RE fe iE fa EL fix Qe gus nee Ee Ee B E i le gt gt 38 didi HB ds SE dett ME o hy Gk Tij En dud
96. USB Cable optional is required eTo transfer data you need to install the FOMA communication setting file driver For details refer to the Manual for PC Connection FOMA communication setting file driver and Manual for PC Connection can be downloaded from NTT DOCOMO website http www nttdocomo co jp english support DOCOMO Connection Manager DOCOMO Connection Manager is a useful software for performing DOCOMO data communications DOCOMO Connection Manager enables simplification of appropriate setting on PC depending on the subscription The fare counter function is also available for checking an indication of the data traffic or usage amount For details refer to NTT DOCOMO website http www nttdocomo co jp support utilization application service connection_manager 78 in Japanese only E oO D lt E D EJ D E Troubleshooting Check if your FOMA terminal needs an update and if necessary update the required software p 84 Ifyou are still unable to identify the problem after checking the points please contact Repairs on the back cover of this manual in Japanese only or a repair counter specified by DOCOMO The power will not turn on Is the battery pack properly attached p 20 Q Has the battery run out gt p 21 Cannot charge the battery The charge lamp flashes does not light up Is the battery pack properly attached
97. ae FOMA EREREB ixi network Base station FOMA packet communication Packet communication compatible access point mopera U Internet service provider fea whew j I j Corporate LAN terminal PC FOMA USB Cable with Charge Function 02 seers a eoo 64K data communication 64K data communication is charged according to the length of time the line is connected regardless of the amount of data Use an access point that supports FOMA 64K data communication such as DOCOMO Internet connection service mopera U or ISDN synchronized 64K access point For 64K data communication connect the FOMA terminal to a PC using FOMA USB Cable with Charge Function 02 or Bluetooth communication or to a PDA using a dedicated cable Note that the communication charge can become very expensive when the line is connected for a long time 255 An access point that is compatible with 255 85 FOMA 64K data communication such as mopera U E E FOMA ISDN EB EE E P sl 5 network network mE EE 64K data communication Base ISDN synchronized 64K access point station Internet service provider PC FOMA USB Cable with Charge Function 02 The communication speed is 384kbps
98. ages moving picture files etc of up to 2 MB in addition to the message The maximum number of the files varies depending on the file size Also the FOMA terminal is Deco mail compatible By changing the character size background color etc and using Deco mail pictograms in the message you can compose and send fun decorative i mode mail i mode mail enables you to use Decome Anime which is Flash movie with messages and images For details on i mode mail refer to NTT DOCOMO website Sending i mode mail Om gt New mail gt Enter each of the EB No address gt gr No subject gt and Eg No message gt items O a Send Bi To attach files On the New mail screen IZ Add att file gt gt Select a file The following files can be attached to i mode mail Still image image SWF Flash movie Moving picture i motion Melody PDF data Document in a microSD card ToruCa ToruCa detail Phonebook data Profile data Schedule or Memo data Bookmark SD other files in a microSD card Movie Movie can be sent as an attachment file only if it is forwarded 51 Sending Deco mail Decome Anime Pana de i gt New Deco Anime Bl Deco mail ll Decome Anime Deco mail is a service that Decome Anime is a service allows you to decorate that allows you to compose i mode mail by changing decorative mail using the character color size and animation templates with backgroun
99. alarm pp 6 Edit gt Enter each item Finish Using Bar code reader Use the camera to scan JAN code or QR code Hold the FOMA terminal firmly to avoid shaking during scanning When scanning bar codes use the camera approx 10 cm away from the bar code he gt Tool Barcode reader gt When the bar code is displayed in the recognition field scanning starts automatically gt e Submenu P Store gt YES OK 8 BH E EN NM Oi Data Management This FOMA terminal supports commercially available microSD cards of up to 2 GB and mics Dale cards of up to 32 GB as of November 2013 Make sure to format microSD card on N 01F You may not be able to use microSD card formatted on another terminal or PC e Visit the following website for the latest information about supported microSD cards such as manufacturers or capacity Contact the microSD card manufacturer for any microSD cards that are not listed on the website From i mode to access N 9 Select the shortcut icon Ji N p 30 8 gt MenuList gt Mobile Phone Manufacturer N Japanese From PC http www n keitai com guide faq in Japanese only Select the model name on the FAQ page and then select Data Management Note that information descr
100. are Select the Update icon gt Yes pp Enter your security code Your FOMA terminal is checked if it needs an update The check result appears Bl When Update is needed appears To download the software immediately select Now update To update later select Reserve and then specify the date and time to update Bl When No update is needed Please continue to use as before appears Continue using the FOMA terminal ZA Running software update from the menu Update Software from the main menu Of gt Setting gt Other setting pp Software Update O Enter your security code gt Update Your FOMA terminal is checked if it needs an update Go to step 2 in Running software update by selecting the icon Scanning function This function detects data and programs that are imported to the FOMA terminal and deletes data or stops launching applications that could cause some fault The Scanning function prevents the data that causes some fault from invading your FOMA terminal when viewing websites or receiving mail If pattern data for a failure is not downloaded to the FOMA terminal or if pattern data for certain failure does not exist it may be impossible to delete the harmful data using this function hi Updating pattern data First update the pattern data to the latest pattern data Oky gt Setting Lock Security Scanning function gt Update gt VES p YES p OK 85 hi Scann
101. are multiple modems sere Select the S4 PILF Y 70 Dial up phone number and enter the number of the access ISP i D 9943 point U NTTDOCOMO You can leave user name and password blank for mopera U connection To connect to any other provider than mopera U P 9 enter the user name and password specified by SEEN SAMPLE the provider or network administrator in the O BOROST 1 User Name and Password columns as this screen ISP This screen is an example of accessing mopera U by packet communication Click Connect and then click Skip To confirm the settings cancel a connection test 30 Click EAU 3 Close Click Network and Internet Connect to a network on Control Panel Right click the name created for the dial up and click
102. ared devices during infrared communication Doing so may cause malfunction of the infrared devices and result in an accident Do not put fluids such as water or substances such as pieces of metal or flammable materials into the miniUIM slot or microSD card slot inside of the FOMA terminal Doing so may cause fire burns injury or electric shock e Please turn off your FOMA terminal when inside an airplane hospital or other area where use is prohibited The terminal may adversely affect electronic or medical equipment If the Auto power function is set make sure to disable the function before turning off the power Follow the instructions provided by the medical facility for the use of mobile phones You will be punished if you take activity prohibited by law such as use of mobile phones in airplanes However use of the FOMA terminal may be permitted by turning off transmissions using radio waves etc but follow airline instructions for proper use Do Make sure to hold the FOMA terminal at a safe distance from your ear when you use the handsfree mode or the ring tone sounds Also when you play games or music etc with an earphone microphone etc connected to the FOMA terminal adjust the volume properly Too large a volume may lead to defective hearing Also hearing difficulties may cause an accident Mise have a weak heart take precautions when setting the Vibrator or Ring volume Failure to obs
103. arks or registered trademarks of Aplix Corporation in Japan and other countries Blend fais a registered trademark of FeliCa Networks Inc QR code is a registered trademark of Denso Wave Inc microSDHC logo is a trademark of SD 3C LLC SAP T micro S2 GIs N MEDIAS VIEWER Quick Shot Art Photo Speed movie Privacy angle and MULTITASK are trademarks or registered trademarks of NEC CASIO Mobile Communications Ltd QuickTime is a registered trademark of Apple Inc in the US and other countries Microsoft Windows Windows Media Windows Vista Excel and PowerPoint are trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries T9 isa trademark or registered trademark of Nuance Communications Inc and its affiliates in the United States and other countries Powered By Mascot Capsule Micro3D Edition MASCOT CAPSULE is a registered trademark of HI CORPORATION PhotoSolid MovieSolid and their logos are trademarks or registered trademarks of Morpho Inc in Japan and other countries Google is a trademark of Google Inc CROSS YOU is a trademark of Sony Corporation Twitter is either registered trademar
104. ata communication using the FOMA terminal and how to install FOMA communication setting file and DOCOMO Connection Manager The procedures or screens may vary depending on your environment The words which represent the FOMA terminal model name such as driver names and modem names are referred to as model name Read model name as your model name The screen images or illustrations used in this manual are examples They may differ depending on the FOMA terminal you use Description of Bluetooth Wi Fi connection and User authorizations is only for compatible models 13 10 8rd Edition Data Communication Data Communication Available for the FOMA Terminal Available data communication between the FOMA terminal and PCs is classified in 3 categories data exchange OBEX M communication packet communication and 64K data communication Data exchange OBEX communication The data such as images phonebook entries mails and more can be exchanged with equipment such as other FOMA terminals and PCs Infrared data exchange Bluetooth communication FOMA terminal FOMA USB Cable with Charge Function 02 microSD card DOCOMO keitai datalink FOMA terminal Packet communication Packet communication is charged according to the amount of data sent and received High speed communication at up to 7 2Mbps downlink and up to 5 7Mbp
105. ating watching screen eee Video Caption Screen status operation mode etc D Adjust the volume E xu 3 Select the channel in order P c8 Mute CO to L9 C LX One touch channel selection FH ma ari ce Record still image by pressing the key while watching start movie recording by pe 35 pressing the key for 1 second or longer while watching stop recording by pressing 1Seg watching the key while recording movie Recorded movie is saved in microSD card screen Display a program information switch the display landscape view only Setting timer watching or recording 1Seg Qe gt CAMERA TV MUSIC gt 1Seg gt TV timer list or Timer recording list gt amp New gt Enter each item Finish Playing recorded video O Ww gt Data box 1Seg Video pp Select a video file 65 Music Playing music data You can play Chaku Uta Full downloaded with i mode Browser or Full Browser as well as WMA data without DRM For details on WMA data refer to Guide Japanese kd gt P b TV ee p gt gt WMA m Guide is not available when English is set for Select language You can enjoy
106. attery pack from the FOMA terminal Failure to observe these precautions may cause fire burns injury or electric shock GE A CAUTION ENS Do not leave the devices on a slope or unstable surface The devices may fall and cause injury Q Do Dont Do not leave the devices in humid dusty or hot places Doing so may cause fire burns or electric shock Dont If your child uses the FOMA terminal instruct him her on how to use it Check if he she always Do uses the FOMA terminal correctly as you instruct Improper usage could result in bodily injury e Keep the FOMA terminal out of young children s reach Do Ayoung child may try to swallow it or suffer injury S Pay special attention when you use the FOMA terminal connected to the adapter po foralong period If you use i appli or videophone or watch 1Seg programs for a long time while charging the temperature of the FOMA terminal battery pack or adapter may rise If you touch the warm part of these devices for a long period oftime it may cause redness itch skin irritation or low temperature burns depending on your constitution or physical condition E 2 Precautions for the FOMA terminal _ GE A WARNiNc REED 9 Dont Do not direct the infrared data port towards your or another person s eyes Doing so may cause eye injury Don t Dont Do not directthe infrared data port towards consumer equipment with infr
107. bes an example using Windows 7 Select gt Control Panel For Windows 8 From the Start screen open the Desktop and then move the mouse cursor to the top right corner of the screen to display the Charm Bar Select Settings gt Control Panel For Windows XP Select Start gt Control Panel Open Systems and security in the Control Panel For Windows Vista Open System and maintenance in the Control Panel For Windows XP Click the System icon in Performance and maintenance Select Device Manager When the User Account Control screen appears click Yes For Windows Vista Select Device Manager When the User Account Control screen appears click Continue For Windows XP Click the Hardware tab and click Device manager Click each device to check the PEL Sc E IRF V H installed driver name a H mt Ch
108. cation Enter in the format of AT DGPIR lt n gt To automatically attach 184 Not notify for dialing an outgoing call answering an incoming call Enter the following AT DGPIR 1 dl To automatically attach 186 Notify for dialing an outgoing call answering an incoming call Enter the following AT DGPIR 2 4 0 00 30 2400 8 N 1 RT DGPIR 1 28 Confirm that OK appears and z sample MANTAS click J brea a T APH Close Hyper terminal in the RT DGPIR 1 File menu 38 0 01 00 2400 8 N 1 The Caller ID needs to be set to Notify to use DOCOMO s internet connection service mopera U About 186 Notify 184 Not notify in Dial up Network You can attach 186 184 to the access point number in the Dial up network settings as well The following table shows what happens if you set 186 184 both for the DGPIR command and the Dial up network setting Dial up network setting for Notify Not notify setting by Notify Not notify Caller ID cid 2 DGPIR command Not set Notify 99 xk ck k 2 Not notify Not notify Notify Notify Not set Not notify Dial up network notification 184 has the 184 99 sk sk sk 2 Not notify priority Notify Not set Notify Dial up network notification 186 has the 186 99 x k k 2 Not notify priority Notify
109. cations charges will apply for each communication 10 Some services are not available depending on the operator or network overseas 49 hi Making a call to outside the country you stay in On the standby screen O 1 second or longer to enter gt Country code Area code City code The other party s phone number py voice call amp V phone After the call ends To make an international call to Japan dial 81 as country code Dial the other party s phone number excluding 0 at the beginning of the area code city code However to make a call to some countries areas such as in Italy 0 is required y Making a call in the country of stay Area code City code gt The other party s phone number voice call amp V phone O After the call ends hi Making a call to WORLD WING user overseas When making a call to WORLD WING user overseas make a call as an international call to Japan dial 81 Japan as the country code irrespective whether the other party is in or out of the country you Stay On the standby screen LO 1 second or longer to enter gt The other party s mobile phone number excluding the first 0 gt voice call amp V phone O After the call ends o0 Only by subscribing to i mode Mail can be exchanged between i mode users or anyone who has an Internet e mail address You can send up to 10 attachments im
110. ce For more information visit the DOCOMO website For Wi Fi connection Packet communication only Set the FOMA terminal to Access point mode For details refer to the Instruction Manual for the FOMA terminal Connect and disconnect 6 Setting the USB mode to Communication mode Set the mode before connecting to PC Setting is not required when using Bluetooth connection or Wi Fi connection MENU key Setting External connection USB mode gt Communication mode Installing the FOMA Communication Setting File Drivers The following procedure explains how to install the FOMA communication setting file drivers Q Before installing the FOMA communication setting file make sure to quit any Windows software running on your computer When installing FOMA communication setting file be sure to log on as Administrator If you attempt to install the file with another account an error may occur Contact your PC s manufacturer or Microsoft for information on how to set Administrator privileges on your PC Install the FOMA communication setting file only when connecting to the PC using the FOMA USB Cable with Charge Function 02 Quit any Windows software including anti virus that resides on the task bar To close software that resides on task bar click an icon on the task bar and click Close or Finish Access the FOMA communication setting file drivers download pag
111. coming call When Reject unknown of Call rejection set is set to Reject also including Secret Incoming call act Alert Show No When Voice mail Call forwarding Call rejection in Arrival call act is set If you make a voice call to an emergency phone number 110 119 or 118 while Public mode Drive mode or Self mode is set the setting will be canceled Using overseas To make calls overseas use international roaming WORLD WING ll International roaming WORLD WING is the service which enables you to make calls and perform communication over networks of affiliated overseas operators using the FOMA terminal phone number and mail address of your own for Japan even when you are overseas Voice calls SMS and i mode mail services are available without any special settings lll Supported area This FOMA terminal is Class 4 and can be used in 3G or GSM GPRS network service areas Also it can be used in countries regions compatible with 3G850 MHz Check available areas lll Before overseas use refer to the following Mobile Phone User s Guide International Services DOCOMO International Services website Bl Information Foracountry code international call access code universal number international prefix available countries and overseas operators refer to Mobile Phone User s Guide International Services or DOCOMO International Services website Overseas usage fees call char
112. cons indicate the status of such as the FOMA terminal and signal reception ll Icons indicating the status of the FOMA terminal At the top of the screen icons indicate the status of the FOMA terminal oo 5 3 ua am C5 D g oO EJ Battery level use this icon as a guide Fully charged E Recharge the battery Signal strength t T Good qem Poor S Outof the FOMA service area Vibrator set Fu amp Ring volume set to Silent Manner mode ON Public mode Drive mode ON Alarm notification function ON dm OH 01 BH Msg The number of Voice Mail messages Unread mail During a voice call Dial lock is set During i mode dv J3N Guide i concier New i concier information for voice videophone calls The number of record VP messages eco mode set Auto key lock set USB cable connected and a Communication mode on Multitask activating microSD card inserted 8 ia 5 Only major icons are covered here To check the names of the icons le gt Setting P Screen Display Icons e4 ll Desktop icons and shortcut icons In the middle of the screen desktop icons indicate the status of new arrivals You can paste shortcut icons with which you can launch d Ailsa Desktop icons examples Am d 91 Missed call BRYS 2 E g Msg Record message i Msg Record VP message s W Voice Mail 01
113. corded in non volatile memory written by amp W nor reset by amp F or Z Format CGDCONT lt cid gt lt PDP_type gt lt APN gt Explanation of the parameters Sets the access point name APN for packet origination See the following command execution example cid 1 10 PDP type PPP or IP lt APN gt 3 Any value 1 cid is a number for managing the access point name APN registered in the FOMA terminal for packet communication For the FOMA terminal you can register a number from 1 to 10 As mopera net is assigned by default to lt cid gt 1 and lt cid gt 3 and mpr ex pkt net to lt cid gt 4 assign the APN to cid2 or cid5 through cid10 2 PDP type is the connection method For the FOMA terminal you can specify PPP or IP By default PPP is assigned to lt cid gt 1 and 4 and IP to lt cid gt 3 Specify PPP when you use the FOMA terminal as an access point for Access point mode 3 APN is an arbitrary character string indicating each access point name Operation performed when the parameter is omitted CGDCONT Sets the initial value to all cid CGDCONT lt cid gt Sets the specified cid to the initial value CGDCONT Displays a list of values that can be set CGDCONT Displays the current setting Command execution example Command for registering an APN name of abc when cid is 5 AT CGDCONT 5 PPP albc OK ll Command name CGEQMIN parameter
114. d color waving Flash movie containing characters etc messages images I Sending Deco mail consi rthdey A Change the font color On Message screen AA Change the font size i Select an image to insert to select a decoration menu then As Blink text compose message gt x Send A Sus Restore the entered text or Font color decoration to the previous 2 3 3 9985 Z Sending Decome Anime state etc Op Create new Deco Anime gt Enter an address and subject gt Bg lt No message gt Select a Decome Anime template p 6 Set Select the Message field then edit the text Finish t Send p A template is a form for Deco mail Decome Anime to which the layout and decoration are already set Using a template allows you to compose Deco mail Decome Anime easily gt Decome Template Deco mail or Decome Anime Reading received i mode mail When the FOMA terminal is in the service area the i mode center automatically sends i mode mail When the reception of i mode mail is completed 44 appears on the standby 52 screen indicating the mail has not been read OW gt Inbox Selecta folder Select an i mode mail hi Replying to i mode mail 0 On Received mail list screen Received mail detail screen 6 0E gt Compose message S
115. d ep E 48 Lis MD Dr 44 Phonebook Add entries a ua uaa DEG bp 55 Delete entries fte tT 55 Editientries soins ei 55 PIN code PIN1 PIN2 LL Laas a sass sass RR tutu saas eas 39 PIN unblocking key PUK LLL LL LLL EL LLL rag 39 Play MOtION suis RR 69 MOVIE mm Ea e 69 MNO 66 MI 65 Playback restriction sssesssseeseesesssscsoceseecsscsosesesee 66 PrecautionS ssssssseitsssssssosesrsoieesssosissssssidseeseosdsorsisneisssd se 5 Privacy NO 35 Profile e 23 Public mode Drive mode 45 Public mode Power OFF ees 46 Received Call 43 Reception level Signal strength 24 Record message setting eere 45 Redial Mee T T 43 Reject unknown fr 41 Reset settingS ose oie nerd ioter b rni Edi Ere spears tet 42 Retrieve mail address automatically 23 hihi 33 RING volume Luu aux FRE aaa ssa TOM REASELOFE XS Cs I 33 SeSIIIMGTUHNGEIO NE 85 Scanning results ISBIBWVEEERRKEOKM Ve 86 Update pattern datd sse 85 SCION eps M M 74 ci24lgadqd c 38 Security Scan Scanning function 85 Select langudde sesion i ii een dee RP PECES UE 23 Shabette Kensaku eeeeeeeeeeeeee rentes 73 Shoot moving pictures eere eeee e
116. deactivate le gt Setting pp Lock Security gt Lock P Enter your security code i OFF f To activate On the standby screen 1 second or longer To deactivate On the standby screen 1 second or longer Enter your security code f To activate fe gt Setting Lock Security P Auto key lock pp Enter your security code gt Selectan item tb Finish fa To deactivate tem porarily On the Auto key lock setting screen enter your security code gt Setting incoming call restriction y Rejecting calls without caller ID Set whether to accept or reject voice videophone calls from unidentified numbers by configuring the setting for each reason Q kw Setting Lock Security Call rejection set O Enter your security code gt Select any item from User unset to Unknown pp Accept or Reject If you select Accept you can set Select ring tone and Select calling disp aT The setting can be configured for each of the following reasons User unset Calls made by callers who opt not to send caller ID Payphone Calls from pay phones etc Unknown From callers who are unable to provide the caller ID such as calls from overseas or calls from land line phones sent via a call forwarding service hi Rejecting calls from numbers not stored in phonebook Set whether to accept or reject calls from callers not in the phonebook Fe gt Setting Lock S
117. der Sea water Swimming pool Hot spring hi Opening closing the external connector terminal cap E Opening Closing Hook your finger on the slot and open the Align the tab on the back of the cap with the cap in the direction of arrow concave of the FOMA terminal then close the cap by pressing securely in direction of arrow Tab on the back of the cap Slot hi Attaching removing the back cover Mi Removing W Attaching Hold the FOMA terminal and hook your finger on Insert the left and right tabs of the back the slot to remove the back cover in the direction cover in direction D and push the back of arrow without applying excessive force on it cover down securely in direction make sure that there is no space between the back cover and the FOMA terminal WW Vcore When removing the back cover make sure that you drain water p 19 and wipe moisture off the FOMA terminal When attaching the back cover make sure that no dust or dirt adheres to the back cover especially to the rubber packing Water or dust might enter the inside of the FOMA terminal unless you attach the back cover securely When attaching the back cover make sure that the miniUIM the microSD card and the battery pack are attached RI If the miniUIM is not securely inserted the battery pack sits on the miniUIM which causes a gap between the FOMA terminal and the back cover when attaching the back cover The waterproof dustproof function mig
118. der the following conditions 8 For Chaku Uta up to approx 10 MB capacity is Phone separately prepared for the Secret Folder Size VGA 640 X 480 QualityzNormal File 9 Shared with images i motion Melody PDF data size 10 MB Sound setting ON Screen memo Music Kisekae Tool Machi chara 1 GB microSD card Internet movies ToruCa i appli and Content SizezVGA 640 x 480 QualityzNormal File package size Unlimited Sound setting ON hi Battery pack Battery Pack N30 DC 3 8V 1010 mAh P Numbers of stored registered protected items in the FOMA terminal Phonebook 1 000 max TV link O O HE 2 5007 ee O 2500 Max 2 500 max 1 000 max 200 max 200 max 5 for mail linked i a ppli p 3 500 max 7 7 gt poe 1000 max O Lo 100 1 O Lo 100 O Lo 25007 O p00 po 2500max T000mac 200max 3 500 max 2 Kisekae Tool 3 500 max Chaku Uta Full Approx 68 1 Up to 50 entries can be stored in a miniUIM 6 Includes pre installed data 2 Includes i schedule 7 Up to 250 images can be additionally stored in 3 Actual storable registerable protectable counts the Secret Folder may be decreased depending on the data size 8 Up to 10 files can be additionally stored in the 4 Up to 20 more received or sent SMS can be Secret Folder additionally stored in a miniUIM 9 Number of stored
119. ding a mobile phone while driving However exceptions are made in case of emergency such as to safeguard injured persons or to maintain public safety e Use the FeliCa reader writer function only in Japan The FeliCa reader writer function of the FOMA terminal complies with radio standards of Japan You may be punished if you use it overseas e Do not modify the system software improperly This may be regarded as remodelling and requests for repair of the terminal may be rejected 15 Waterproof Dustproof Function N 01F is waterproof to IPX5 and IPX7 standards and dustproof to IP5X standard if the external connector terminal cap is closed as well as the back cover is securely attached 1 IPX5 means that the N 01F continues to function as a phone after being sprayed from all directions with 12 5 liters of water per minute from a 6 3 mm diameter nozzle for at least 3 minutes from a distance of approx 3 meters 2 IPX7 means that the N 01F retains phone functionality after slowly immersing in still room temperature tap water to a depth of 1 meter and leaving it there for 30 minutes before bringing it out of the water 3 P5X means the level of protection IP5X means that N 01F continues to function as a phone and to maintain security after being left in a device containing dust diameter 75 u m or smaller for 8 hours agitated and removed The waterproof dustproof capabilities of N 01F You can talk or watch 1Seg
120. display MyFACE setting Color theme setting Each display setting Sub display setting Machi chara setting oft key Original menu Menu display se Viewer settings cons cons setting Privacy angle Image display mode Quick Info setting Mainitem Subitem Screen Display Information display Manner mode setting Machi chara chat set Text display input haracter input set Select language Lock Security uto key lock all rejection set Change security code UIM setting Battery External USB mode connection Headset microphone emtocell Other setting Side key guard Set assigned function Alarm setting Map Overseas i concier rofile Other setting Mainitem Subitem Branch item Map imadoco search i area Map setting Overseas NW search Overseas setting lselfmode Memory refresh Reset settings Initialize Software Update Error info send set Quick search URL imadoco kantan search imadoco search 3G GSM setting Network search setting PLMN setting Display operator name Display area status Re search icon Inquiries overseas Sub clock setting Bar incoming when roam Missed call notice Roaming guidance Int l dial assistance mode service set Mail Message usage set Network service Osaifu Keitai Subitem Branch item lCcardcontent DCMX ToruCa IC card lock IC card lock sett
121. e above copyright notice this list of conditions and the following disclaimer Redistributions in binary form must reproduce the above copyright notice this list of conditions and the following disclaimer in the documentation and or other materials provided with the distribution Neither the name of the HTS working group nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED IN NO EVENT SHALL THE COPYRIGHT OWNER OR f Description on Windows OMTI Ltd ERER The abbreviations of operating systems Japanese versions below are used in this manual Windows 8 stands for Microsoft Windows 8 Microsoft Windows 8 Pro and Microsoft Windows 8 Enterprise Windows 7 stands for Microsoft Windows 7 Starter Home Basic Home Premium Professional Enterprise and Ultimate Windows Vista stands for Windows Vista Home Basic Home Premium Business Enterprise and Ultimate Windows XP indicates the Microsoft Windows XP Professional operating system or Microsoft Windows XP Home Edition operating system This FOMA terminal Supports SIM lock emoa Removing the SIM lock allows you
122. e country you stay For international call access codes for major countries and universal number international prefix refer to DOCOMO International Services website If you lose your FOMA terminal or have it stolen immediately take the steps necessary for suspending the use of the FOMA terminal If the FOMA terminal you purchased is damaged bring your FOMA terminal to a repair counter specified by DOCOMO after returning to Japan Don t forget your mobile phone or your manners When using your mobile phone in a public place don t forget to show C common courtesy and consideration for others around you y Sales NTT DOCOMO INC Manufacturer NEC CASIO Mobile Communications Ltd us 2013 11 1st Edition Li ionOO Manual for PC Connection Data Communie aoe ene a cn ence nar coer era ane ede 1 ES SIN Gyre cae are LEE Ir 4 Checking the Procedures cece sete ne 5 Installing the FOMA Communication Setting File Drivers 8 Preparing Bluetooth Communication eeeeesssss 12 Connecting to a Wi Fi compatible PC sesssseess 14 DOCOMO Connection Manager 15 Executing Set Data Communication 20 Setting Wp Did up Network tee 22 SCN OL DIAU pm ud 30 P Orosio B c Pe d NU E m 42 About Manual for PC Connection This manual describes necessary information for d
123. e fire burns injury or electric shock Dont If the display is broken and the inner substance such as liquid crystal leaks do not allow it to come in contact with your face hands etc Failure to observe this precaution may cause loss of eyesight or damage to your skin If the inner substance such as liquid crystal comes into your eyes or mouth immediately rinse with clean water and see a doctor If the liquid crystal adheres to your skin or clothing immediately wipe it off with alcohol and wash with soap and water Do Before using your FOMA terminal in a vehicle ask the manufacturer or sales agent whether the operation of the vehicle can be affected by radio waves In some types of vehicle using the FOMA terminal may interfere with the operation of the vehicle s electronic equipment In this case stop using the FOMA terminal immediately Do There may be cases where the customer s physical condition or predisposition leads to itchiness rashes or sores If this occurs immediately stop using the FOMA terminal and see a doctor Material used in each part p 11 7 Material List Take care not to pinch your fingers or the strap when opening folding the display of the FOMA terminal Such pinching may cause injury o When viewing the display keep a proper distance between your eyes and it in a bright place Failure to observe this precaution may impair your vision BI Re
124. e it to strong shocks Doing so may cause malfunction e Do not bend the miniUIM or place a heavy object on it Doing so may cause malfunction e Do not put a label or sticker on the miniUIM when attaching it to the FOMA terminal Doing so may cause malfunction Handling the FeliCa Reader Writer e The FeliCa reader writer function of the FOMA terminal handles delicate signals that require no radio station license e The 13 56 MHz frequency band is used If there is another reader writer around keep enough distance between the FOMA terminal and the reader writer Also make sure that there is no radio station using the same frequency band nearby Cautions e Do not use the altered FOMA terminal Using an altered device is a violation of the Radio Law Telecommunications Business Act A Technical Conformity Mark affixed on the manufacturer s specification sticker certifies that the FOMA terminal meets technical regulations for specified radio equipment based on the Radio Law and technical regulations for terminal devices based on the Telecommunications Business Act If you remove the screws and alter the inside of the FOMA terminal the technical regulations conformity certification becomes invalid Do not use the FOMA terminal with the certification invalid as it is a violation of the Radio Law Telecommunications Business Act e Be careful when using the FOMA terminal while driving A penalty may be imposed for hol
125. e on DOCOMO website Access http www nttdocomo co jp support utilization application foma com set driver index html in Japanese only e Go to the driver download page for the in use model Upon confirming the user agreement click Agree to agree it Mlfthe File Download Security Warning screen appears Click Save o Specify the destination to save and download the file Double click the downloaded file model name driver exe model name driver win8 exe for Windows 8 and click Execute Follow the onscreen instruction to specify the destination to extract the file Read ReadMe txt in the model name driver folder created at Step 5 and double click an installation file that is compatible with the in use OS When the User Account Control screen appears click Yes for Windows 8 and Windows 7 and click Continue for Windows Vista For Windows XP the User Account Control screen is not displayed Click SST zx Install driver Installation starts FOMA When this screen appears click OK The title bar display differs depending on the in _ FOMA
126. e signal strength is enough Reboot the power or remove the battery pack or miniUIM then insert it again Depending on the signal quality you may not be able to make or receive calls even if the signal strength icon shows T T Move to another location and try again Is Call rejection Call acceptation or another restriction applied Depending on the network congestion you may have difficulty talking or mailing in crowded places In this case you see the message Please wait and hear the busy tone Move to a location and try again or perform the operation later Still images or movies shot with the camera look blurred Is the camera lens cloudy or dirty When shooting a subject close up set Auto focus to Close up Is Shake correction set to OFF s Auto focus set to OFF Osaifu Keitai cannot be used When the battery pack is removed or Omakase Lock is set the IC card function cannot be used regardless of the IC card lock setting Have you activated IC card lock or Dial lock Are you holding the 4 mark of the FOMA terminal over a reader unit 8 Warranty and After Sales Service SATE Make sure that a warranty is included when you purchase the FOMA terminal Check the content information about the shop date of purchase etc Keep the warranty card in a safe place If the warranty card does not contain n
127. ecessary information immediately contact the shop and request them to fill in the card The warranty is valid for one year from the date of purchase written on the warranty The product in whole or in part including its accessories is subject to improvement without notice y After sales service If your FOMA terminal needs repairs Before having your FOMA terminal repaired see Troubleshooting in this manual or in Guide Japanese that is installed in FOMA terminal If you still have problems please contact Repairs on the back cover of this manual in Japanese only If after contacting DOCOMO you are informed that your FOMA terminal needs repairs Bring it to a repair counter specified by DOCOMO The repair counter is only open during business hours Depending on the malfunction repairs may take some time Within the warranty period Repairs will be made free of charge based on the provisions of the warranty Bring the warranty card when requesting repairs Charges will apply even when the FOMA terminal is still under warranty if the warranty card is not submitted or if malfunction or damage damage on the display connector etc is the result of mishandling by the subscriber Charges will apply even WIR the warranty period for repairs resulting from use of devices and accessories not specified by DOCOMO Repairs may not be possible in the following circumstances The repair counter
128. echnology developed by Sony Corporation FeliCa is a registered trademark of Sony Corporation Contains Adobe Flash Lite and Adobe Reader Mobile technology by Adobe Systems Incorporated Adobe Flash Lite Copyright 2003 2013 Adobe Systems Incorporated All rights reserved Adobe Reader Mobile Copyright 1993 2013 Adobe Systems Incorporated All rights reserved Adobe Adobe Reader and Flash Lite are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and or other countries This product contains NetFront Browser NetFront Document Viewer and NetFront Sync Client of ACCESS CO LTD ACCESS the ACCESS logo and NetFront are registered trademarks or trademarks of ACCESS CO LTD in the United States Japan and or other countries Copyright 2013 ACCESS CO LTD All rights reserved This software is based in part on the work of the Independent JPEG Group ACGESS NetFront This product contains IrFront of ACCESS CO LTD IrFront is a registered trademark or trademark of ACCESS CO LTD in the United States yrFront Japan and or other countries iWnn OMRON SOFTWARE Co Ltd 2008 2013 All Rights Reserved AXIS Font is a trademark of AXIS Inc and the AXIS font is a font developed by Type Project Inc on SRS VIP licensed by SRS Labs Inc This product contains software Manufactured under license from Audyssey Laboratories U S PREMIUM MOBILE
129. eck that all the driver names are displayed under COM LPT Ports COM amp LPT Modems and Universal Serial Bus Controller or USB Universal Serial Bus four USB Universal Serial Bus controller AS iit is displayed p or USB Universal Serial Bus A nx on Windows Vista and Windows XP n FOMA Intel R 82801EB USB Universal Host Controller 24D2 Intel R 82801EB USB Universal Host Controller 24DE Intel R 82801EB USB2 Enhanced Host Controller 24DD USB Root Hub USB Root Hub USB Root Hub Device name Driver name COM LPT e FOMA model name Command Port FOMA model name OBEX Port FOMA model name or USB Universal FOMA model name Serial Bus When you check the above if not all the driver names appear follow the uninstall instructions p 11 to delete the FOMA communication setting file and install the proper f
130. ecognition results may vary depending on factors such as your surroundings and the way you speak Packet communications charges apply to use Using Voice quick start From the standby screen you can activate and execute a function by voice This function is convenient when you do not know under which menu the required function belongs to or when you want to activate a function quickly Voice quick start is not available when English is set for Select language When using for the first time select Use on the usage guide screen or press s Start On the standby screen 1 second or longer Within 10 seconds say the keyword for the function into the mouthpiece microphone when kE Pk Say the keyword appears e If the function cannot be determined search for a candidate in Guide Japanese Speak clearly at natural conversation speed e Recognition results may vary depending on factors such as your surroundings and the way you speak 7 oO D lt E lt D EJ D E 74 Using schedule Save a schedule to notify you of the saved content with an alarm sounding at the specified date and time a message and animation appearing Tool Schedule gt Select the date gt M Submenu gt New gt Enter each item 6 Finish Using alarm We gt Tool gt Alarm gt Select an
131. ect Set Play Send etc shows Set Edit Finish Play Send New etc OQ shows Back microSD Set etc shows Change Delete Set etc Q shows an icon 4D to indicate direction available for moving or scrolling vertically and horizontally Press amp 5 to move or scroll the direction Menu operation You can select various functions of the FOMA terminal from the main menu which appears when you press he on the standby screen Q ey gt to move the highlight then Select gt Select the displayed menu sequentially Ml aj 12 19THU 12 05 Te ed Pos 4 fg ea CAMERA TV MUSIC ua Ss cD f es oO gt ww as al XU eu 2222 aN TP Osaifu d s jm i concier rofile Keitai You can play and enjoy image MUSIC dyk HPT Guide etc EC emn EA Select 7 gt Oy NN Non If no key is pressed for 15 seconds or longer while the main menu is displayed the main menu ends and the previous screen reappears hi When Submenu is displayed When BEE is displayed at the bottom left of the screen pressing be displays functions which can be used on the screen such as saving editing and deleting When the submenu contains more menu items ET is displayed ee docomo Palette UI You can switch from the standby screen t
132. ecurity Call rejection set O Enter your security code gt Reject unknown gt Accept or Reject S This function is valid only for calls with caller ID It is recommended that you also set Caller ID request and User unset in this function 4 Resetting to default hi Resetting the function settings to default c the function settings to default For the function that can be reset see Menu ist p 88 Initialize and Reset settings are different Do not mix them up If you perform Initialize you will lose all data you have stored lt ua m Ss cD f es oO gt Q kw Setting Other setting pp Reset settings Enter your security code YES hi Deleting stored data at once Delete stored data and reset the function settings to default Performing Initialize deletes all of your important data logs or information such as personal data like phonebook entries or mails downloaded images or melodies i appli Widget Appli PDF data the photo images still images or moving pictures shot by camera or various log records or information etc protected data is also deleted Of Setting P Other setting Initialize Enter your security code YES pp YES LN W Ne Pre installed data will not be deleted However Osaifu Keitai compatible i appli that is deletable may be deleted Pre installed i app
133. ed by your Internet service provider or the network administrator Contact the Internet service provider or network administrator for details Required conditions for performing packet and 64K data communication The following conditions are required to perform communication using the FOMA terminal For communication in Japan Your PC is compatible with the FOMA USB Cable with Charge Function 02 optional You are in the FOMA service area For packet communication the access point supports FOMA packet communication For 64K data communication the access point supports FOMA 64K data communication or ISDN synchronized 64K However depending on congestion of the base station or weaker signal strength you cannot perform communication even when the above conditions are satisfied Before Using Operating environment The PC operating environment to use data communication is as shown below Operating environment It as Data communication DOCOMO Connection Manager PC unit PC AT compatible model When using the FOMA USB Cable with Charge Function 02 optional USB port compliant to Universal Serial Bus Specification Rev1 1 2 0 When using Bluetooth communication Bluetooth Specification Ver 1 1 Ver 1 2 or Ver 2 0 EDR compliant Dial up Networking Profile When using Wi Fi connection wireless LAN standard IEEE 802 11b or IEEE 802 1g compliant Display resolution of 800 X 600 dots or better Display resol
134. ed or around 4096 battery level Handling the Adapter e The ambient temperature of the room should be 5 C to 35 C e Do not charge the battery pack In ahumid dusty or unstable place Nearaland line phone TV or radio e It is normal that the adapter become warm while charging Keep using it e Do not use the DC adapter to charge the battery when the car engine is not running Doing so may drain the car battery e If you use an electrical outlet with an unplugging protection mechanism follow the instructions of the manual for the outlet e Do not expose the adapter to strong shocks Do not deform the charging terminal Doing so may cause malfunction Handling the miniUIM e Do not apply excessive force to the miniUIM when attaching removing it Note that the warranty does not cover damage caused by inserting the miniUIM into another type of IC card reader or writer e Always keep the IC part clean e Wipe with a soft dry cloth such as an eyeglass cleaning cloth e Please keep a separate record of the information you have registered in your miniUIM Please be aware that DOCOMO bears no obligation or responsibility in the event that data is altered or lost e To preserve the environment bring discarded miniUIM to a docomo Shop or Service Counter e Do not damage scratch unnecessarily touch or short circuit the IC Doing so may cause data loss or malfunction e Do not drop the miniUIM or expos
135. ee of battery pack The battery pack is consumable The operation time for battery packs steadily decreases with each charge When the operating time has become extremely short even though the battery pack has been fully recharged please purchase a new battery pack The power is turned off or turned back on suddenly Soiled terminals of the battery pack may result in poor connections and loss of power When soiled wipe with dry cotton swab Key operations are not available If you bring the FOMA terminal near magnetic products you may not be able to perform correct key operations Keep the FOMA terminal away from magnetism Is Dial lock Omakase Lock set p 40 Is Auto key lock set p 40 Is Side key guard set to ON A miniUIM cannot be recognized Is the miniUIM inserted correctly into your FOMA terminal p 20 Clock shows wrong time Clock may show wrong time if you leave the power on for a long period of time Confirm that Auto time adjust is set then reboot the power at a location with good signal quality Cannot make a call by pressing the dial keys Is Original Lock for Keypad dial under Dial sending mail set gt p 40 Is Auto key lock set p 40 Is Restrict dialing set Is Dial lock set gt p 40 Is Self mode set Calls cannot be made or received does not disappear even after e move You cannot make or receive calls despite th
136. end To quote the received message to reply press amp HE3 I Checking new i mode mail You can receive the i mode mails and messages stored at the i mode center by checking with the center On the standby screen M 1 second or longer P J Sorting i mode mail Sort mail into the specified folders by preset criteria such as mail address or subject On the Outbox Inbox folder list screen highlight the destination folder pp Submenu gt Auto sort Seta sort criteria Early warning Area Mail for 1 second or longer ll What is Area Mail Area Mail is a service that enables you to receive Early Warnings and tsunami warnings issued by the Japan Meteorological Agency When the FOMA terminal is in the service area Area Mail is automatically received Asubscription to i mode is not necessary to receive Area Mail Area Mail cannot be received regardless of the Receive setting in the following cases The power is off s amp is displayed During a voice call During a videophone call During international roaming n Omakase Lock In Self mode During infrared communications iC transmissions During Memory refresh process 53 54 hi Receiving Area Mail When you receive Area Mail a special beep or ring tone sounds and FJ appears at the top of the screen hi Setting Area Mail OW P Mailsetting Area Mail setting gt Select an item Using SMS This service
137. ent of the sticker cannot be confirmed determination of whether technical standard is satisfied cannot be made Thus requests for repair may be rejected The settings of the functions may be cleared reset due to the damage repair or improper use of the FOMA terminal In this case configure the settings again Magnetic components are used for the following parts of the FOMA terminal A cash card ATM card bank card etc which is easily affected by magnetism may become unusable if it is kept close to the components Parts speaker earpiece and key areas This FOMA terminal is waterproof However if any internal part of your FOMA terminal gets wet or moist immediately turn the power off remove the battery pack and bring the FOMA terminal to a repair counter as soon as possible Note that rapal may not be possis cepenaing on me condim Error info send set if an error occurs with the FOMA terminal select whether or not to send the recorded error information to DOCOMO Even if an error occurs it may not be recorded depending on the type of error The recorded information is sent to DOCOMO at night Packet communications charges do not apply to sending error information The sent information does not include information that will identify the sender le gt Setting pp Other setting Error info send set gt Enter your security code pp ON or OFF a3 i mode fault diagnosis site The
138. ere eene 62 Shoot still images eee cree eee eere enne 62 Shorteut ICON e 25 Signal strength Reception level 24 SMS 54 Software update coiere rr rrr rx rien rie ped epus 84 Specific absorption rate SAR 94 Specifications Battery paCk dee 93 Numbers of stored registered protected items 93 PUNO IN d Rd Stand by display niae ete tio terni Prep rimo een evbasbes DETUR security GO Troubleshooting Using Brigii e ENT SDOFECUE dise edes ern E ERE EIEPANU ANUS SERRREIR E UEUMR DE Tem Settind PR Videophone call MD 43 Overseas DS uade pM RN UNDE Cd 49 nil 44 big Leone 24 Viewing sub display eee 25 Voice Mail Service eiecise eite ieo snos aao kee ea terio 47 Voice quick start unii RO RYE ERELMYEPIHETS POR POUR P DERE 73 jit 45 lus 82 Waterproof dustproof function 16 When you cannot answer a call Public mode Drive mode trn 45 Public mode Power OPE uidentes tien indeed 46 Record message acies ores EERox v Ep FeH IE Ep c UE 45 WMA c 66 WORLD C BEL oin smasci ced nie NO aM rx eem d WORLD WI c po e or w d bcr A oe s1 4 0 103 Make various app
139. erve this precaution may affect your heart Do If you are wearing electronic medical devices ask the manufacturer or sales agent whether the devices can be affected by radio waves before using your FOMA terminal The terminal may adversely affect electronic medical devices Please turn off the power near electronic equipment that contains high precision mechanisms or handles delicate signals The terminal may interfere with the operation of sensitive electronic equipment Electronic equipment to watch out for Hearing aids implanted pacemakers ICDs and other electronic medical devices fire alarms automatic doors and other automatically controlled apparatus Users of implanted pacemakers ICDs and other electronic medical devices are advised to ask the manufacturer or sales agent whether or not these devices can be affected by radio waves e Do If the display or camera lens is broken be careful with the broken glass and any exposed FOMA terminal parts A plastic panel is used for the display or the surface of the camera lens to prevent glass from shattering However touching broken or exposed parts may cause injury Don t et ct o a a Dont GEN A CAUTION ED Do not swing the FOMA terminal by its strap or other parts The terminal may strike you or others around you resulting bodily injury Do not use the damaged FOMA terminal Doing so may caus
140. es that you must unplug the power cord from the outlet Safety precautions are explained in the following categories Precautions for the FOMA terminal Battery Pack Adapter Desktop Holder and miniUIM Common ss m II p 5 Precautions for the FOMA terminal Precautions for the Battery Pack Precautions for the Adapter and Desktop Holder Precautions for the miniUIM Precautions for Use Near Electronic Medical Devices Material List Precautions for the FOMA terminal Battery Pack Adapter Desktop Holder and miniUIM Common NDANGER Do not use keep or leave the devices in locations subject to high temperatures near a fire or heating unit in a kotatsu under direct sunlight inside a car on a hot day etc Doing so may cause fire burns or injury Do not put the devices in a microwave oven or pressurized container Doing so may cause fire burns injury or electric shock Do not disassemble or modify the equipment Doing so may cause fire burns injury or Nodisasemby electric shock er ct o a A No liquids Do not allow the devices to become wet with liquids such as drinking water or other water pet urine or sweat Doing so may cause fire burns injury or electric shock For waterproof function refer to the following p 16 Waterproof Dustproof Function No liquids Do not allow liquids drinking water or other water pet urine sweat etc to enter the chargi
141. et for Select language gt Tool gt gt n F Guide O Enter the keyword or select searching E AN method 44 MABE Guide screen s Character Entry Entering characters When entering information to save to the phonebook or creating mails or schedules enter text 2 Entering characters 3 Converting entered text Press Chrct on Press a dial key several times Convert entered text to the text entry screen to enter your desired text Kanji or Kana to display entry mode amp Example when pressing C2 Q Display conversion change screen didates When entering Alphabetic candida a bc ABCo2 e Select from the candidates Convert to Kanji etc to change the When entering Kanji Hiragana Conversio nde 4 Convert to Alphabetic 1 Switching entry modes When entering Numeric 2 When entering Kana Numeric and Kana 2 Set ll Other key operations Delete character Insert a line feed switch upper case lower case or enter dakuten handakuten Return to t
142. etwork Select Set up dial up connection and click RAN Next If the modem selection screen appears click the in use FOMA terminal When connecting wirelessly using Bluetooth communication click the in use Bluetooth linked standard modem or Bluetooth modem provided by a Bluetooth device maker The modem selection screen appears only if there are multiple modems Select the Phone number for dial up and enter the number of the ISP access point D 99 3 You can leave user name and password blank for s San e mopera U connection oe A To connect to any other provider than mopera U EU FOXTERATSG enter the user name and password specified by 1Z0 X7 FRI T B 8 the provider or network administrator in the REZIN SAMPLE User Name and CAU F l P d thi A SSWOT COIUMNS as IS screen N I
143. f data or temporary keeping or transferring data contact the Osaifu Keitai service provider For important data please be sure to use the Osaifu Keitai service supporting the backup service Please be aware that DOCOMO is not responsible for loss or alteration of the IC card data any monetary losses incurred while using Osaifu Keitai services under any circumstance such as malfunction or changing your model If your FOMA terminal is stolen or lost contact the Osaifu Keitai service provider immediately and seek for advice li ToruCa ToruCa is an electronic card that can be captured with the FOMA terminal and you can conveniently utilize it with application of flyers restaurant cards coupons etc ToruCa can be obtained from the reader websites or data broadcast etc and you can readily trade items through mail infrared communication iC transmission and a microSD card The captured ToruCa is saved in ToruCa of Osaifu Keitai For details on ToruCa refer to NTT DOCOMO website lt D em oO mej lt D D gt t 70 Using Osaifu Keitai By holding the 4 mark printed on the FOMA terminal over the reader unit you can make payments with e money or utilize as tickets Even when the power is turned off or the battery is running out the IC card function is available by holding the A mark over the reader Hold the A mark over the reader
144. fer to the information shown on the battery pack label to check the type of battery Display Battery type GEN DANcER ENS Don t Do not place metal items such as wires in contact with the charging terminals Also do not carry or store the battery pack with metal items such as necklaces Doing so may cause the battery pack to ignite explode overheat or leak Don t Check the orientation of the battery pack before attaching it If you have difficulty attaching it to the FOMA terminal do not put excessive pressure on the battery pack Failure to observe this precaution may cause 2 ie pack to ignite explode overheat or leak 9 Don t Do not throw the battery pack into fire Doing so may cause the battery pack to ignite explode overheat or leak Dont Do not puncture the battery pack hit it with a hammer or step on it Doing so may cause the battery pack to ignite explode overheat or leak e Do If battery fluid etc comes into contact with your eyes do not rub your eyes but immediately rinse your eyes with clean water and see a doctor Failure to observe this precaution may result in loss of eyesight GE A WARNINc ENS Don t Never use the battery pack if it has fallen to have something abnormal such as deformation and damage Failure to observe this precaution may cause Pis e pack to ignite explode overheat or leak Do o If the battery pack leaks or em
145. g Sets the pause time second by using the comma dial Automatic disconnection delay time setting 1 10 second Disconnects the line when there is no user data exchange for the time set in this command Sets the called sub address character 1 10 Initial value Only 7 10 can be specified ATS4 Displays the current setting Initial value Only 7 8 can be specified Displays the current setting This command can be set but cannot be operated This command can be set but cannot be operated This command can be set but cannot be operated 7 0 Inactive timer off initial value 7 0 255 Where n is the number of minutes 0 1 initial value 2 Y Y mark or back slash 32323 50 ATS4 10 OK ATS4 010 OK ATS5 8 OK ATS5 008 OK ATS6 5 OK ATS6 005 OK ATS6 ERROR ATS8 3 OK ATS8 003 OK ATS8 ERROR ATS10 1 OK ATS10 001 OK ATS10 ERROR ATS30 0 OK ATS30 000 OK ATS30 ERROR ATS103 0 OK ATS108 000 OK ATS103 ERROR AT command Outline Parameter description Command execution example ATS10427 Sets the calling sub address 7 0 ATS104 0 character 1 1 96 initial value OK N 2 amp ATS104 000 OK ATS104 SF ERROR AIV 77 Specifies whether the result 720 Returns the result code in numeral ATV1 code is returned in numerals value OK or alphabets 7 1 Returns the result code i
146. g on the current location or signal quality The location information and phone number are not disclosed when before each individual call made 184 or another blocking prefix is dialed first If the information is deemed necessary for the protection of life etc this information may be acquired by the organization being called Locations timing planned for adoption of this feature vary according to the status of the preparations by the relevant emergency service organizations When calling 110 119 or 118 from the FOMA terminal first say you are calling from a mobile phone give your number and state your location clearly because the police or fire department may call you back for confirmation Also do not move around when making the call Do not turn off the power immediately after ending the call but leave it turned on for ten minutes or so so that you can receive a call Depending on the area you are calling from you may not be connected with the nearest police or fire department etc 47 48 When making a videophone call to 110 119 or 118 from the FOMA terminal the call automatically changes to a voice call If you make a voice call to an emergency phone number 110 119 or 118 the following functions will be disabled and then set again automatically after approximately 5 minutes Call rejection Call acceptation Call forwarding Voice mail Org lock Original Lock Incoming Mail disp In
147. g destination is set to Phone W To display a screen memo Me gt i mode web Screen Memo p Select a destination Select a screen memo D NO Up to 200 bookmarks can be registered for i mode and Full Browser Up to 250 screen memos can be stored for i mode and Full Browser Some pages cannot be saved as screen memos e g if saving is prohibited on the page 58 Peas ee res ES i channel i channel is a news and information service distributed for i mode subscribers with i channel compatible terminals The ticker on the standby screen shows latest information that is automatically delivered to your terminal Basic Channel This channel is distributed by DOCOMO Packet communications charges do not apply to automatically update basic channels Okonomi Optional Channel This channel is distributed by information service providers IP Packet communications charges apply to automatically update Okonomi Optional Channel Detailed content will be subject to packet communications charges for both Basic Channel and Okonomi Optional Channel The packet communications charges apply both to automatically update and to view detailed content when used overseas and they differ from those in Japan j channel requires a subscription and is a fee based service i mode subscription is required For details on i channel refer to NTT DOCOMO website The i channel service is only availab
148. ge packet communications charge differ from those in Japan hi Available services overseas MYFACE O O lt Voice cal 0 0 Videophone call 0 x x SMS 0 0 o Lmode SS mode mail i A E channel NE CUNE ee Widget o 6 Packet communications via a PC O x 1 Auto upd set roam setting is required Packet communications charges will apply when you automatically update MyFACE content that was registered at the time of purchase When traveling overseas from Japan MyFACE auto update set is set to Don t auto update When using auto update for the first time select whether or not to auto update overseas 2 When 2in1 is active dialing using Number B is not available Dialing using the additional number of Multi number is not available 3 When sending an SMS to FOMA terminal user enter the other party s phone number as in Japan 4 i mode overseas use setting is required 5 i channel overseas use setting is required Packet communications charges will apply when you automatically update information on Basic Channel Included in i channel charges in Japan 6 Overseas use setting for i concier is required Packet communications charges will apply for each reception of information 7 i Widget overseas use setting is required When you open the i Widget screen multiple Widget Appli may establish communications In this case packet communi
149. he FOMA terminal ATON Returns from the online n 0 Returns from online command mode ATO command mode to the to online data mode can be omitted CONNECT online data mode during communication ATQN Specifies whether or notto 7 0 Displays the result code initial value ATQO display the result code for n 1 Not display the result code OK DTE ATQ1 At that time OK is not SF amp W returned 49 AT command ATSO N amp F amp W Outline Specifies how many times the FOMA terminal rings before it automatically receives a call Parameter description 7 0 No automatic answer initial value N 1 255 A call is automatically answered after the specified number of rings ATSO Displays the current setting Command execution example ATSO 0 OK ATSO 000 OK ATS22n 8F Sets an escape character 77 493 N 127 ATS2 Initial value Escapes processing is invalid Displays the current setting ATS2 43 OK ATS2 043 OK ATS3 SF Sets a carriage return CR character 1 198 Initial value Only N 13 can be specified ATS3 Displays the current setting ATS38 13 OK ATS3 013 OK ATS4 77 SF ATS5 n SF ATS6 n SF ATS8 n SF ATS10 n SF amp W ATS30 n SF ATS108 7 SF Sets a line feed LF character Sets a backspace BS character Sets the pause time second until a dial startin
150. he previous character assigned to that key 1 second or longer Undo the operation such as pasting or cutting Enter Pictograph or symbols consecutively or enter face marks or URL While displaying List pressing MM or i switches the tabs 3 Let s enter text Example entering Autumn camp gt Enter Hiragana 2j als gt to move the cursor to the target conversion x candidate and then to select the candidate to lower case Select 3 times oc oO Ss cD E f es oO Han dakuten hi Entering Deco mail pictogram Deco mail picture Deco mail pictograms Deco mail pictures are images that meet certain conditions including moving pictogram Press PI SB on the Message screen and then use fe or B to display the Deco or D picture tab Use to move the frame and press Select to enter a Deco mail pictogram or Deco mail picture Pressing under the Deco tab displays the categorized Deco mail pictogram entry screen 3e Sound Screen Setting Changing ring tone hi Changing the ring tone for calls Of gt Setting Sound Vib Manner Select ring tone Phone Select ring tone Melody Select ring tone S jy Other options such as a melody i motion Chaku Uta or Chaku Uta Full can be set to ring tones When i motion is set a video also plays Chaku Uta and Chak
151. honebook of mobile phone Data to be registered APN Phone number cid Memory number of Phonebook Other party s name How to register Hegister using PC Available DOCOMO Connection Available Dedicated software Manager etc required Register using Mobile phone Unavailable Cannot even check Available How to use Specify cid to connect Look up Phonebook to call Enter the telephone number directly from the dial key on the FOMA terminal to call Registered cid will be connection numbers in the dialup connection settings Q Contact your Internet service provider or network administrator for an access point APN other than mopera U 1 Set up the APN setting for the access point Internet service provider on the FOMA terminal in advance instead of entering APN in the Telephone Number column of Dial up Network for connection 2 To connect to other Internet service providers set the APN and assign it to cid2 and cid5 through cid10 Example Using the FOMA USB Cable with Charge Function 02 on Windows XP Connect the FOMA USB Cable with Charge Function 02 optional to the FOMA terminal Turn on the FOMA terminal then connect the FOMA USB Cable with Charge Function 02 connected to the FOMA terminal to the PC 26 Click Start All programs tU Accessories C
152. ht deteriorate because of the gap 18 To maintain waterproof dustproof function replacement of parts is recommended once every 2 years regardless of whether the FOMA terminal appears normal or abnormal DOCOMO replaces the parts as a chargeable service Bring the FOMA terminal to a repair counter specified by DOCOMO Important notices If the FOMA terminal gets wet with water or other liquids with the external connector terminal cap or the back cover open the liquid may get inside the FOMA terminal causing electric shock or malfunction Stop using the FOMA terminal turn off the power remove the battery pack and contact a repair counter specified by DOCOMO The external connector terminal cap and the rubber packing of the back cover play an important role in maintaining waterproof dustproof function Do not remove or scratch them Also prevent dust from adhering to them If the external connector terminal cap and the rubber packing of the back cover is damaged or deformed replace it at a repair counter specified by DOCOMO Do not insert sharp objects through the gap of the external connector terminal cap or back cover Doing so may damage the rubber packing and allow water to seep or dust to get in If the back cover is damaged replace it Water may seep into the inside of the FOMA terminal through a damaged section causing electric shock corrosion of the battery pack or other malfunctions Do not leave the
153. ibed on the website is only the result of the operation check and does not guarantee all operations Turn off the power before inserting or removing a microSD card Do not put a label or sticker on a microSD card Keep a backup copy of data stored in a microSD card Please be aware that DOCOMO is not responsible for any damages the subscriber may incur due to the card data being deleted erased or altered Inserting removing microSD card Q Remove the back cover O Slide the metal holder in the direction of arrow OPEN and lift it up Do not touch the metal contacts of the FOMA terminal when lifting the holder up Do not apply excessive force to the holder when sliding it you could damage the holder or hurt your hand or fingers 75 E oO D qm oO E lt D EJ D E 76 Insert the microSD card straight and slowly along the rails Rail with the metal contacts facing you To remove the microSD card hold the microSD card and slowly pull it out along the rails O Close the metal holder and slide it in the direction of arrow LOCK to lock If the holder does not close properly lift the holder up and make sure that the microSD card has been properly inserted along the rails and inserted deep enough O Attach the back cover When you turn on the power after inserting the microSD card sj appears hi Formatting microSD card Note that all data in the microSD card will be deleted when you format it
154. ibes how to set it up using Hyper terminal that comes with Windows XP Windows 8 Windows 7 and Windows Vista are not compatible with Hyper terminal For Windows 8 Windows 7 and Windows Vista set with software compatible with your operating system Access points lt APN cid gt Q Normal telephone numbers are not used for access points for packet communication unlike 64K data communication Set up APN instead of a telephone number for connection Q Setting up the APN is just like registering a phonebook for packet communication from a PC When registering assign registration number cid 1 through 10 which is used as a part of the access point number As the APN of mopera U mopera net is assigned by default to cid1 and cid3 and the APN of mopera U mpr ex pkt net to cid4 assign the APN to cid2 and cid5 through cid10 1 APN is administered by cid administration numbers 1 through 10 Specifying 99 x cid number as the access point number enables the connection to the access point with the cid number Specifying 99 x sk sk 1 x 99 x GR 3 or 99 x 4 as the access point number for the mopera U connection enables you to use mopera U easily lt Q The APN setting registers the access point to the FOMA terminal just like registering other parties information telephone number etc on a mobile phone The following are comparisons with the Phonebook of the mobile phone APN setting P
155. ile You can play and enjoy image MUSIC etc EE ria Ce Mail i mode web i a pli Data box Tool Setting Map Overseas Display the i concier screen Display the miniUIM own number etc Osaifu Keitai i concier Profile Display the mail functions Display the menus of i mode and Full Browser pp Display the i appli menu CAMERA TV MUSIC Display the menus of Camera MUSIC Player and 1Seg Display folders in Data box Display useful functions TEL function Display phone functions such as the phonebook dialed received calls etc Display the setting menu of the FOMA terminal Display the menus of Map and Overseas setting Display the setting menus of IC card ToruCa etc Original Display the original menu ll Changing the design of the main menu You can change the design of the main menu background icon etc Choose from Standard Colourful neco Simple Original theme and Kisekae Tool Oky A Kisekae Selecta design Key operation The soft keys Function display corresponding to 6 and the direction icons corresponding to are displayed on the screen These icons appear only when the corresponding keys can be used hi Performing the functions assigned to the function key lll Display examples and assigned functions shows Submenu Exit MENU etc O shows Sel
156. ile 10 Uninstalling the FOMA communication setting file drivers If necessary when updating the drivers etc uninstall the drivers as follows The procedure for uninstalling from a Windows 7 or Windows Vista machine is described as an example Uninstallation is not available while connecting the FOMA terminal with PC When uninstalling FOMA communication setting file be sure to log on as Administrator If you attempt to uninstall the file with another account an error may occur Contact your PC s manufacturer or Microsoft for information on how to set Administrator privileges on your PC If the FOMA terminal and the PC are connected by the FOMA USB Cable with Charge Function 02 optional remove the FOMA USB Cable with Charge Function 02 Start Applications and functions on the Windows Click gt Control Panel Uninstall a program For Windows 8 From the Start screen open the 7 AZ ky 7D Desktop and then move the mouse cursor to the u zr top right corner of the screen to display the Charm Bar gt Click Settings gt 77 KO b Control Panel Uninstall a program For Windows XP Click Start gt Control Panel gt
157. ing C lock power off Auto lock setting Setting ToruCa settings Receive ToruCa IC card notice se lCcardusage 1 CheckIC owner IChangeICowner Searchby mode 9 N O1F S Height approx 110 mm x Width approx 51 mm x Thickness approx 14 4 mm Thickest Approx 17 4 mm Stationary AUTO Approx 430 hours Continuous talk time EE 1 o 1Seg watching time Display Display Approx 3 4 inches Sub display Approx 0 8 inches Image ed 8 1 mill pixels Camera 8 0 mill pixels P ixels Record No of photos that When saved to Phone Up to approx 1 300 can be stored When saved to 1 GB microSD card Up to approx 9 999 5 1085 hoto file format JPEG Moving picture When saved to Phone Approx 83 sec per moving picture total of recording time approx 29 min 34 When saved to 1 GB microSD card Approx 120 min per moving picture total of approx 130 min When saved to 1 GB microSD card Up to approx 320 min Total When saved to 32 GB microSDHC card Up to approx 10 240 min Total Continuous playback is Windows Media Audio WMA file Up to approx 6 7 x 16 levels Approx 210 MB 1 Switch networks in 3G GSM setting 5 Varies depending on the broadcaster and 2 Size VGA V 480 x 640 Quality Normal File program size 95 KB 6 File format AAC 3 Varies depending on the size 7 Background playback supported 4 Recording time un
158. ing companies broadcasters Communications charges do not apply to receive video and voice data For details on NHK receiving fees contact NHK Packet communications charges apply to view data broadcast site and i mode site Information charges may apply for some sites i mode pay sites For 1Seg service details visit the following website The Association for Promotion of Digital Broadcasting Dpa From PC http www dpa or jp english i mode http www dpa or jp 1seg k in Japanese only ll Broadcast waves 1Seg is one of the broadcast services and receives signals broadcast waves different from those of FOMA services In locations such as the following the signal reception status may become weak or out of service Far from the signal tower Hiding behind objects e g in a mountain or building In tunnels underground areas and some locations far inside buildings The 1Seg antenna is built in You may be able to improve reception by keeping the FOMA terminal away from close to your body or moving to another location Caution With the ending of analog waves some channels have been reorganized For this reason it may be necessary for you to reset the channels yourself by automatic setting p 65 After resetting a channel be sure to register the setting in the channel list For details of the Terrestrial Digital Channel Repack visit the following website etc Channel Update Call Center Consultation Center for Terrestrial
159. ing results display lll Scanned problems display follwing orobiens A list of up to 5 problems detected by the Scanning function appears were detected Problem element starting with the highest level problem Problem element2 PMG o MaNi If 6 or more problems are detected the names of the 6th and ia subsequent problems are omitted Return lll Scanning results display Warning level 0 Warninglevel 1 Warninglevel 2 Warninglevel3 Warning level 4 Operation may not Operation may not Operation may not Operation may not Operation may not run properly run properly run properly run properly run properly Cancel operation Canceling operation Delete data Deleting data OK Continue YES Stop and cancel OK Stop YES Delete the dataand OK Delete the the operation the operation and cancel the cancel the operation data and cancel NO Continue the operation NO Stop and cancel the the operation operation operation Options and related devices By combining various options and accessories sold separately your FOMA terminal can support a wide range of applications to meet both your personal and professional needs Note that some products may not be available depending on the area you are in For more information contact a docomo Shop or Service Counter For details of options and accessories refer to relevant User s Manual Earphone Microphone 01 FOMA USB Cable with
160. ion of your FOMA terminal malfunction damage water exposure etc It is recommended that you back up necessary data Please note that it may not be possible to back up some data such as downloaded data ll Note Never remove the battery pack while updating software Doing so may cause the update to fail Charge the battery fully before updating software Software updates downloading and rewriting may take time While software is being updated functions such as making calls receiving calls or communication functions and other functions are not available While downloading voice calls can be answered tis recommended that you perform software updates when the FOMA terminal is stationary and in a location with good signal quality three bars for the antenna icon If the reception becomes poor and then the download is interrupted try to update again in a location with good signal quality When software is updated the unique information model serial number etc of your FOMA terminal is automatically transmitted to the server at DOCOMO We do not use the transmitted information for any purposes other than Software Update f the update fails the message Rewrite failed will appear and all operations will become unavailable In this case please seek advice at a repair counter specified by DOCOMO hi Running software update by selecting the icon Select the icon HAm Update icon on the standby screen to update softw
161. is due to automatic changes to the power level of the device to ensure it only uses the minimum required to reach the network Therefore in general the closer you are to a base station the lower the power output of the device This mobile phone can be used in positions other than against your ear This mobile phone satisfies the international guidelines when used with a carrying case or a wearable accessory approved by NTT DOCOMO INC In case you are not using the approved accessory please use a product that does not contain any metals and one that positions the mobile phone at least 1 5 cm away from your body The World Health Organization has stated that a large number of studies have been performed over the last two decades to assess whether mobile phones pose a potential health risk To date no adverse health effects have been established as being caused by mobile phone use Please refer to the WHO website if you would like more detailed information http www who int docstore peh emf publications facts press fact english htm Please refer to the websites listed below if you would like more detailed information regarding SAR Ministry of Internal Affairs and Communications Website http www tele soumu go jp e sys ele index htm Association of Radio Industries and Businesses Website http www arib emf org index02 html in Japanese only NTT DOCOMO INC Website http www nttdocomo co jp english product sar NEC CASIO Mobile Communications
162. it Click the Network tab and set up each setting Check ony 4 TCP IPv4 Internet Protocol version 4 TCP IPv4 in the ZOS ecl ROIB A ZEH Use the following items for this connection Click the 1 ZZ 3 Z7 Options tab and click PPP PPP settings D Clear all the boxes and click OK 15 Click OK 34 re H SAMPLED TD C74 HBO 8 SE P Gob A Df N 3 S R Pe DD eee OT co C LOP E aR TPES ezi TUN Setting up dial up on Windows Vista ab Open O Access point Click Setup the connection or n
163. its an unusual odor stop using it immediately and move it away from any flame or fire The battery fluid is flammable and could ignite causing a fire or explosion Keep your pets away from the battery pack as they may accidentally bite it Failure to observe this precaution may cause En Mad pack to ignite explode overheat or leak Do If the battery pack leaks do not touch battery fluid etc with your face hands etc Failure to observe this precaution may cause loss of eyesight or damage to your skin If the battery fluid etc comes into your eyes or mouth or it adheres to your skin or clothing immediately rinse with clean water In the case that it comes into contact with your eyes or mouth see a doctor immediately after rinsing GEN A WARNiNc EE Don t Do not use the adapter if its power cord is damaged Doing so may cause fire burns or electric shock Don t GEE A caution a C Don t 9 Don t Do not dispose of used battery packs with ordinary garbage Doing so may cause fire and create an environmental hazard Put insulation tape on the terminals of used battery pack and return it to a docomo Shop or Service Counter or dispose of the battery pack in accordance with your local regulations Do not use or charge the wet battery pack Doing so may cause the battery pack to ignite explode overheat or leak Do not use the AC adapter or desktop holder in humid loca
164. k or trademark of Twitter Inc in the United States and or other countries All other company names and product names appearing in this manual are trademarks or registered trademarks of their respective holders A THIS PRODUCT IS LICENSED UNDER THE MPEG 4 VISUAL PATENT PORTFOLIO LICENSE FOR THE PERSONAL AND NON COMMERCIAL USE OF A CONSUMER FOR i ENCODING VIDEO IN COMPLIANCE WITH THE MPEG 4 VISUAL STANDARD MPEG 4 VIDEO AND OR ii DECODING MPEG 4 VIDEO THAT WAS ENCODED BY A CONSUMER ENGAGED IN A PERSONAL AND NON COMMERCIAL ACTIVITY AND OR WAS OBTAINED FROM A VIDEO PROVIDER LICENSED BY MPEG LA TO PROVIDE MPEG 4 VIDEO NO LICENSE IS GRANTED OR SHALL BE IMPLIED FOR ANY OTHER USE ADDITIONAL INFORMATION INCLUDING THAT RELATING TO PROMOTIONAL INTERNAL AND COMMERCIAL USES AND LICENSING MAY BE OBTAINED FROM MPEG LA L L C SEE HTTP WWW MPEGLA COM TEXT INPUT THIS PRODUCT IS LICENSED UNDER THE AVC PATENT PORTFOLIO LICENSE FOR THE PERSONAL USE OF A CONSUMER OR OTHER USES IN WHICH IT DOES NOT RECEIVE REMUNERATION TO i ENCODE VIDEO IN COMPLIANCE WITH THE AVC STANDARD AVC VIDEO AND OR ii DECODE AVC VIDEO THAT WAS ENCODED BY A CONSUMER ENGAGED IN A PERSONAL ACTIVITY AND OR WAS OBTAINED FROM A VIDEO PROVIDER LICENSED TO PROVIDE AVC VIDEO NO LICENSE IS GRANTED OR SHALL BE IMPLIED FOR ANY OTHER USE ADDITIONAL INFORMATION MAY BE OBTAINED FROM MPEG LA L L C SEE HTTP WWW MPEGLA COM FeliCa is a contactless IC card t
165. ker etc on the display or keypads Doing so may cause malfunction or damage Do not remove the microSD card or turn off the power while in use Doing so may cause data loss or malfunction Do not let magnetic cards etc come close to or be sandwiched between FOMA terminal parts The magnetic data in cash cards credit cards telephone cards floppy disks etc may be erased Do not let strong magnetic objects come close to the FOMA terminal parts Strong magnetic objects may cause misoperation Handling the Battery Pack e The battery pack is consumable Battery life varies depending on usage conditions etc but it is time to change battery packs when the usage time has become extremely short even though the battery pack has been fully recharged In this case please purchase a new battery pack e The ambient temperature of the room should be 5 C to 35C e The available operating time of the battery pack depends on the conditions of usage and battery pack e Depending on the usage condition the battery pack may inflate slightly when the battery life is almost over This is not a malfunction e Do not store the battery pack in the following cases e The battery is fully charged immediately after the charging is complete The battery has run out the phone cannot power on The performance and life of the battery pack may deteriorate It is recommended that you store the battery pack with two battery marks display
166. l oppli i Widget i appli are software applications that run on i mode compatible terminals You can automatically receive updated stock prices weather information etc and play games without being connected to the network by downloading i appli from i mode sites The FOMA terminal also supports i appli online which allows you to make online communication with multiple users using real time communication and cppli call You can enjoy versus games chat application etc Some i appli programs are available for i Widget Communication charges may apply depending on the i appli i Widget is a convenient function that allows you to access frequently used content and tools Widget Appli such as calculator clock memo and stock price information You can paste multiple Widget Appli up to 8 on the i Widget screen and enjoy multiple applications at a time just by displaying the i Widget screen If you select a desired Widget Appli you can also obtain more detailed information You can add Widget Appli by downloading from sites When i Widget screen is displayed multiple Widget Appli may be connected to network Detailed content will be subject to packet communications charges Fordetails on i appli and i Widget refer to NTT DOCOMO website Packet communications charges incurred overseas differ from those in Japan Activating i o ppli On the standby screen 8 1 second or longer pp Select a software Downloading applications fro
167. l up communication service Unable to connect with the Check if the settings for the ID user name and password are correct access point fthe access point requires the Caller ID make sure that 184 is not added to the phone number Check if the box of Use the flow control of the modem property is checked Check if the APN is set correctly If you still cannot connect to the other end after checking the above consult with the Internet service provider or network administrator about the setting method 41 AT Command List AT commands available on FOMA terminal The following abbreviations are used in the AT command list amp F Command of which setting is initialized by AT amp F command amp W Command of which setting is saved by AT amp W command The setting can be retrieved by ATZ command When you make a call via an external device or using AT command the call is made from Number A in A mode Dual mode and from Number B in B mode Modem port command list The followings are the usable commands for FOMA model name modem When you execute commands via Bluetooth connection a single byte space is inserted after each in the results AT command Outline Parameter description Command execution example A Executes the last executed A command again No carriage OK return is necessary AT The modem function of a FOMA termi
168. le appears but it is not necessary to save The AT commands entered in Hyper terminal may not be displayed after Step 7 on p 28 In this case if you enter ATE1 4 AT commands you enter from then on are displayed To reset the access point APN settings using the AT command If reset the access point APN setting for cid 1 and cid 3 returns to mopera net default value and cid 4 to mpr ex pkt net default value cid 2 and cid 5 through 10 will be unregistered How to enter AT CGDCONT ell to reset all cid AT CGDCONT lt cid gt 4 to reset a certain cid only To confirm the access point APN settings using the AT command Display the current settings How to enter AT CGDCONT di Notifying or Not notifying the Caller ID You can set whether to notify the other person of your caller ID when packet communication is carried out Since the caller ID is important information please take care when you send your caller ID You can set up the Notify or not notify Caller ID setting using the AT command prior to a dial up connection Use the DGPIR command p 43 to notify or not notify the caller ID or change back to Not set Default value Start Hyper terminal For how to start Hyper terminal see Setting up the access point APN p 26 Set up Notify 186 or Not notify EUTETSTETENN 184 Caller ID for packet 76 Wt PO io BED ws communi
169. le in Japanese Displaying i channel If you have subscribed to i channel the ticker on the standby screen shows information when it is delivered to your terminal On the standby screen 59 60 E T Start the i appli to display a map Oky gt Map Overseas Map hi Setting Map Select the i appli you want to set from the Map Appli list Map Appli is set by default le gt Map Overseas gt Map setting pp Select Map tee E NE NE L4 BOE iz m EL s Camera Viewing and operating shooting screen y Viewing and operating shooting screen B um CD ETELEES sized screen Photo still image shooting screen Movie moving picture shooting screen 1 Remaining storage count Memory info 2 Save 9 Scene 4 Focus frame 5 Zoom Submenu setting status 7 Key operation guidance 8 Display orientation 9 Quality White balance 9 Self timer 2 Recording time 3 Shooting status Sound setting 9 Quality lll Main key operations Shoot Mw Submenu Switch photo movie shooting 8 Activate Medias viewer CLR Auto Focus lock release 9 Auto Focus lock amp 9 Zoom Wide Zoom Tele 1 J Camera mode 8 Scene 8 J Auto focus 4 J Size 5 J Brightness 6 Shake correction 7 J ISO sensitivity Photo Filesize Movie 8 Other 9 J Show hide icons X J Switch Standard Quick Shot Help 3 Switch
170. lecta folder pp deca movie ll License WMDRM Windows Media digital rights management Movies protected by license cannot be played Windows Media DRM10 is not supported 69 De JE Osaifu Keitai Osaifu Keitai ToruCa Bl Osaifu Keitai Osaifu Keitai allows you to use Osaifu Keitai services in which you can make payments or use coupons by holding the FOMA terminal over a reader in a shop and Kazashite Link services in which you can access site information and other information by holding the FOMA terminal over a reader You can check e money received or balance and remaining points and use the Omakase Lock and IC card lock as a preventive measure in case of theft or loss For details on Osaifu Keitai refer to NTT DOCOMO website To use the Osaifu Keitai services download Osaifu Keitai i appli from the Osaifu Keitai site and make the settings or make the settings on the Osaifu Keitai site 1 gt Menu List P Osaifu Keitai Japanese Data including e money and points stored in the IC card may happen to be erased or altered due to the malfunction of the FOMA terminal As a general rule data should be deleted by the owner itself before undergoing repairs because the FOMA terminal cannot be kept for repair if it has data in it For supports such as reissue or restore o
171. li Widget Appli will be deleted if they have been upgraded or deleted then downloaded Data stored registered set in a miniUIM or microSD card will not be deleted Charge the battery fully before initializing Initialization may not be possible if the battery is low Do not turn off the power while initializing 42 Call Telephone Making a call videophone call The image sent to the other party during a videophone call is the substitute image Chara den or rear camera image because the N 01F does not have a front camera hi Making a call by entering the phone number O Enter the phone number starting with the area code then voice call GJ V phone O After the call ends hi Making a call from phonebook Add the phone number of the other party to the phonebook in advance gt p 55 Search phonebook to select a search condition and search the phonebook pp to select an entry then voice call 4 1 second or longer V phone hi Making a call with redials Q y gt TEL function Dialed Received call Redial to select the other party then voice call V phone lll To make a call with received calls MeM pp TEL function Dialed Received call Received calls pp All calls or Missed calls to select the other party then voice call amp V phone 43 Using Koe no Takuhaibin This is a service to record a voice message and deliver it to
172. lications or change your billing plan check your charges and points and more online i mode access iMenu gt User support gt Applications procedures gt Various applications procedures in Japanese only No packet communications charges appl PC access My docomo http www mydocomo com gt Various applications procedures in Japanese only You need your Network security code to use via i mode Packet communications charges do not apply to use via i mode Charges will apply if using the service from overseas docomo ID password are required to use this site from a PC Please contact General Inquiries on the back cover of this manual if you forget or do not have Network security code or docomo ID password May not be available in some cases depending on the conditions of your subscription There are cases where the site may not be available due to system maintenance etc p Using mobile phone with your manners When using mobile phone in a public place don t forget to show courtesy and consideration for others Turn the power off when you are BE in places where use is prohibited In an airplane or hospital follow the instructions given by the respective airline or medical institution Turn off the power in a location where use is prohibited Always set
173. ll the FOMA communication setting file driver Download the file from the DOCOMO website and install it Data exchange Install DOCOMO keitai datalink in addition E Packet communication and 64K data communication For USB connection For Bluetooth connection Download and install the FOMA Connect the FOMA terminal to a PC communication setting file drivers wirelessly using Bluetooth communication Connect to PC p 12 Install the FOMA communication setting file by downloading from the DOCOMO website gt p 8 Connect the FOMA terminal to the PC with the FOMA USB Cable with Charge Function 02 optional Check the setting after installation p 10 Check the modem p 13 To set up the access point using Not using DOCOMO Connection DOCOMO Connection Manager Manager gt Download DOCOMO Connection Manager from the DOCOMO website and install it to PC Enables you to use DOCOMO Connection Manager Installing DOCOMO Connection Manager p 17 Set up mopera U Set up communication not using DOCOMO Connection Other providers Manager gt p 22 Connect and disconnect Connect and disconnect Connect gt p 20 Connect p 40 Disconnect p 21 e Disconnect p 41 To use Internet with the FOMA terminal and PC connected mopera U you need to apply for is useful which supports broadband connection etc Consider the plan in which you are charged only in a month when you use the servi
174. lume with 4 2 v When you can not answer a call ZA Setting record message When you cannot answer a voice or videophone call the FOMA terminal can record a voice or videophone message Ok gt TEL function Rec msg Voice memo p Record message setting ON pp Phone or Videophone Select an item Set ring time 3 digit number between 000 and 120 seconds Bi If you receive a call with Record message setting ON Record message activates if the set time ends Press to answer a voice call videophone call while recording lll To play a recorded message On the standby screen e P ig Record message or Ema Record VP message gt Select an item AZ Setting Public mode Drive mode When Public mode Drive mode is set a caller hears a message that you cannot answer the call because you are driving or in a place where you have to refrain from using a mobile phone on a train or bus in a theater etc then the call ends automatically On the standby screen 1 second or longer 2 appears on the standby screen 45 46 ll To release the setting On the standby screen 1 second or longer When Public mode Power OFF is set a caller who made a call while the power is off hears a message that you cannot answer the call because you are in a place where you have to turn off the mobile phone in a hospital on an airplane around a priority seat on a train etc then the call end
175. m sites You can download i appli whose size is up to approx 10 MB and Widget Appli from i mode sites Select an application from an i appli Widget Appli downloadable site YES Riso Up to 200 applications can be stored for i appli and Widget Appli Activating Widget Appli On the standby screen 1 second or longer Select a Widget Appli 68 motion Movie i motion Movie i motion is sounds moving pictures etc Download i motion from i motion downloadable sites to the FOMA terminal You can download and play various movies provided on websites such as portal sites or moving picture sites When downloading streaming movies the received file size may become very large Note that packet communications charges may be high when large files such as streaming type with no file size restriction are received For details on packet communications charges and billing plans refer to NTT DOCOMO website Downloading i motion movie Select i motion or movie from an i motion downloadable site pp When the i motion or movie can be saved Save pp YES Select a folder ll Download type Streaming type When i motion movie download starts the playback starts simultaneously Standard type Download type When data download is finished the Download screen appears prompting you to select an option such as to play back or to save Playing i motion movie O P Databox pp i motion Movie pp Se
176. me menus may change in accordance with the frequency of use i oO Ss cD f 7 oO gt Changing illumination when receiving Set the illumination flashing color or pattern used when you receive voice videophone calls mails MessageR F or i concier information Changing the illumination for incoming calls Of Setting Backlight lllum gt Illumination setting Illumination in call Illumination Phone O Select a color gt gt Set pattern Selecta pattern ip Nion e You can set different flashing colors to arriving calls or mails from the specified phone numbers mail addresses and a set of group li To set the flashing color to phonebook On Phonebook detail screen fe Submenu Set Ring tone Image Select the tab of the item to set pp Illumination 36 Checking missed calls or new mail with illumination Set whether to keep the illumination flashing or to stop flashing hi Setting illumination Q kw Setting gt Backlight lllum Illumination setting Illumination in call Missed info ON or OFF hi Checking with illumination When there is a missed call or new mail i mode mail Message R F Area Mail or SMS notification is made with the illumination which keeps flashing Setting eco mode When eco mode is set the settings are collectively changed to reduce battery consumption This is useful for
177. music by copying WMA data without DRM from your PC to the PRIVATE NEC MUSIC folder on a microSD card Of gt CAMERA TV MUSIC pp MUSIC Player All music Selecta track Some programs tracks have playback restrictions i or appears at the beginning of the title for the program track with restrictions on the play count period or time limit The program track whose playback period is restricted cannot be played before or after the period If the battery pack is removed for a long period the date and time stored on the FOMA terminal may be reset In this case the program track whose playback period or time limit is restricted cannot be played You cannot download Chaku Uta Full whose size exceeds 5 MB or Chaku Uta Full whose size is unknown 66 DIVO w A Artist name Elapsed time minutes seconds Total playback time minutes seconds Repeat status Sound quality Equalizer etc Sound effect applied Volume Level 0 to 25 OO No 0001 0001 XXXXX 2 010010 gt 00 02 03 00 STEREO _EQ OFF CIO Pause Resume playback 5 Adjust volume Playback from the beginning of the track Play the previous track by pressing the key within 3 seconds from the beginning of the track O3 Play the next track 1 second or longer Skip backward 1 second or longer Skip forward 6 Stop M Display music list 8 BGM playback 67
178. n characters amp F SW initial value ATXn Specifies whether the speed 7 0 Without dial tone detection without ATX1 indication is present in the busy tone detection without speed OK CONNECT display when display connecting the line 7 1 Without dial tone detection without Also detects a busy tone or busy tone detection with speed a dial tone display 1 2 With dial tone detection without busy tone detection with speed display 7 3 Without dial tone detection with busy tone detection with speed display 7 4 With dial tone detection with busy tone detection with speed display amp F amp W initial value ATZ Resets the current setting to Online command the contents of the non mode volatile memory ATZ If this command is input NO CARRIER during communication the Offline command line will be disconnected mode ATZ OK In response to the escape Online data mode sequence the online data mode changes to the online command mode while maintaining the line connection 91 No display OK Supplementary explanation of AT command ll Commands which do not function The following commands do not generate errors but will not function as a command ATT Tone setting ATP Pulse setting ll Command name CGDCONT parameter Outline Sets the access point name APN for packet origination Though this command is a setting command it will not be re
179. nal is AT controllable by adding the command of this OK table after this command OK is answered even when only AT is entered AT V Displays the version of the AT V FOMA terminal Ver1 00 OK AT amp C7 Selects the operating 7 0 CD is always ON AT amp C1 condition of the circuit CD n 1 CD changes according to the carrier of OK amp F amp W signal to DTE the other party s modem initial value AT amp D N Selects the operation to 1 0 Ignores ER status always assumed AT amp D1 take place when the circuit to be ON OK ER signal received from DTE 7 1 When ER changes from ON to OFF it transits between ON and becomes an on line command status OFF 7 2 If ER changes from ON to OFF a connection is disconnected and it will be in an off line command status initial value amp F amp W AT amp EN Selects how to display the 7 0 Displays the wireless network AT amp EO connection speed transmission speed OK 1 1 Displays the DTE serial transmission amp F amp W speed initial value AT amp FN Restores all of registers to Only 77 2 0 can be specified can be omitted At the time of off line their defaults If this mode command is input during AT amp F communication the line will OK be disconnected AT amp F ERROR AT amp F ERROR At the time of on line command mode AT amp F NO CARRIER Change to off line mode AT amp Sn Sets the Data Set Ready n 0 DR is always
180. ng Bluetooth communication select the in use Bluetooth linked standard modem or Bluetooth modem provided by a Bluetooth device maker The Select the device screen appears only if there are multiple modems COMx is a number of COM port displayed in Checking the COM port p 22 msg Iw 3 Enter any name you want in the ISP ire ISP Name and click RW x 9 Next SP ISP SAMPLE Cee fL mw Enter the number of the access HURBI point in the Telephone SEE Number Soin and click AES Py Next m This screen is an example of accessing SER SAU U EC ET LOB E SR SUA LEEDS ERO mopera U by packet communication Click Next You can leave user name and password blank for PINAATTI MENAI REETH mopera U connection s F c J de ie E o To connect to any other provider than mopera U DEN exci epo cites d enter exact information specified by the provider INE XS or network administrator in the E ae a
181. ng terminal or external connector terminal Doing so may cause fire burns injury or electric shock o Do Don t Use the options specified by NTT DOCOMO for the FOMA terminal Failure to observe this precaution may cause fire burns injury or electric shock GS A WARNING ED Do not apply excessive force to the FOMA terminal throw it or expose it to strong shocks Doing so may cause fire burns injury or electric shock Don t Dont Do not place electrically conductive objects wires pencil leads etc in contact with the charging terminals or external connector terminal Do not insert those materials inside the terminal Doing so may cause fire burns injury Or electric shock Do not cover or wrap the devices with bedding etc while in use or charging Doing so may cause fire or burns Make sure to turn off the FOMA terminal and stop charging before you get close to the places like a gas station where a flammable gas is generated Failure to observe this precaution may cause the gas to ignite Turn off the power when you use Osaifu Keitai at a gas station if the IC card lock is set turn the power off after the lock is released If something unusual happens such as unusual odor overheating discoloration or deformation during use charge or storage be sure to Unplug the power cord from the power outlet or the cigarette lighter socket Turn off the power Remove the b
182. nication Required devices The following hardware and software in addition to the FOMA terminal and a PC are required e FOMA USB Cable with Charge Function 02 optional or FOMA USB Cable optional e FOMA communication setting file drivers 1 ForUSB connection 2 Download the file from DOCOMO website Purchase the specified FOMA USB Cable with Charge Function 02 or FOMA USB Cable The USB cable for PC cannot be used because the shape of the connector is different The FOMA USB Cables may not function properly when connected to a USB HUB Checking the Procedure In data communication the connection is made through a dial up connection with Internet service providers or LANs that support FOMA data communication The FOMA communication setting file is software driver needed for connecting the FOMA terminal with a PC via a FOMA USB Cable with Charge Function 02 optional to carry out packet communication 64K data communication and data transfer OBEX communication Installing the FOMA communication setting file embeds each driver into Windows Using DOCOMO Connection Manager you can easily set up packet communication and 64K data communication and create a dial up connection Flow chart for completing the data communication setup li Data exchange OBEX M communication Install the FOMA communication setting file driver to use the FOMA USB Cable with Charge Function 02 Download Insta
183. not notifying the other party of the Caller ID in outgoing call call is received when m 1 NW setting notifying the other party CLIP 1 is set of the Caller ID in outgoing call RING m 2 Unknown OLIP O9OXXXXXXXX 177 SF SW 123 136 AT CLIR2 7 Sets whether or not to notify 720 Complies to the CLIR service contract Al CLIR 0 the other party of the phone 7 1 Not notify the other party of the OK number when originating a caller s phone number 64K data communication n 2 Notify the other party of the caller s AT CLIR call phone number initial value CLIR 0 1 OK AT CLIR Displays the current setting AT CLIR CLIR Am CUR 0 2 m 0 CLIR is not started Caller ID is OK always sent m 1 CLIR is started Caller ID is always not sent m 2 Unknown m 3 CLIR temporary mode default is not notify m 4 CLIR temporary mode default is notify AT CMEE 27 Sets whether the error 7 0 Use the ERROR result initial value AT CMEE 0 report of the FOMA terminal 721 CMEERROR lt err gt result code is OK is present used and a numeral value is used for AT CNUM enm ERROR 122 CME ERROR lt err gt result code is used AT CMEE 1 and characters are used for err OK AT CMEE ATE NUN Displays the current setting e R The command displayed on the right is the ERE execution example for cases when there isa AT CNUM FOMA terminal problem or a connection error 4CME ERROR SIM not inserted
184. nter for a replacement Remove the back cover gt p 17 oo 5 3 ua Ss D g oO E O Insert the miniUIM Cut corner Insert the card into the slot until it locks in place in direction D with the gold colored IC side down eli IC side down O Attach the battery pack With the side marked A facing up attach the battery pack in direction making sure that its metal terminal fits into the FOMA terminal s metal terminal then press the battery pack down in direction 3 O Attach the back cover p 17 eo Charging For the charging time and continuous talk time refer to Main specifications p 92 The battery pack AC adapter and provided desktop holder are not waterproof dustproof Never charge the battery with the FOMA terminal left wet It is recommended that the desktop holder be used for charging to prevent water from seeping inside and dust from getting in through the external connector terminal The charge lamp lights up when charging starts The charge lamp turns off when charging ends fully charged AZ Charging using desktop holder With the arrow l de f Plug the connector of the AC adapter optional horizontally M odd facing the face with an engrave mark up into the external connector terminal on the back of the provided desktop holder O Plug the AC adapter into the outlet 100V AC Connector O Holding down the desktop holder insert the
185. o 4 Fat SS HH SS Be i OS qs qd E AS SO Cat ME WE d M mu RR DOR E S d SR dB HI 4 iol SY cu e IN giu NIS ha En 28 2H S a Eo c E all ll S cc fee pea Tay Fey S i 5 ort Best om EER RSS gr mH SARS DX NS z N E Bb Sr TN ud Se IE y a ee ee menit Pri KS DH eh C3 MA lt Th tim ASA XR sn cr u Shao cu rh um Ni zh E Bi St E At EH SBS Bg SF eas AT ee RS UNE ME adl Si EISE SR E gt gt t c4 SI i 1n AR di Sb E E Bn KEE R RR T OSES SS OSI 7 d SU SE BIAS MRI Sk Siw HOS SIRS SS OR ae SAEN cm HA dH ASE ge it MIDS v DH ASS aS Sth pp pen Ss s Raus mE T E m E 4 fl XS MMI Skee Bsa Satta mel DS HO H SS a ih Se 3 b See Sk KAD A ca Se MEM TEE NON A S RE 8 8 i M ft DB Ed d 3 Soe et ER IE Ii HS 35 T TL ine AY OSS SIT oH ER SS T n SO dt bt LIS HOS SS 5 A St ang Jo NK SH E Kur EE a m leet DS ne RNa ike IVES Sas ba x e oe It m B SI pa 8 Eu E a 88 28 a D b W A CF EE AB SA SE HH Se ST EE eB Sa Es di ERG am RES d oS EARD RHM MNR SSA D Pees ote bl B pop i EH ifr eh SE TELLS A SHE E SR Ol gj 0S d Fat A Db m Iss Eit AAS AO 9r FA 6 d BR Ten EEG TEE UN cet a at Pelt ed ch Si a y n wh MH SHO SIS 3t Stags uj ay
186. o the MyFACE and shortcut list and easily access various functions or services In addition you can freely customize this new function hi Using MyFACE Activating MyFACE On the standby screen Dial Rcv list 112 19 11 25 a Sue 912 19 10 17 sm sm i 12 m z i 1 CE z 2 l oe i concier Guide z a an ll Downloading MyFACE content from sites You can download MyFACE content up to approx 600 KB from i mode sites Select MyFACE on a MyFACE downloadable site gt to select where to register the content Select YES or NO whether to automatically update the content or service AN Sore You can register up to 12 MyFACE contents Downloading upgrades of MyFACE will result in packet communication charges 29 co ue am O Ss cD w oO EJ 30 JAE ll Activating a shortcut 5 or more shortcut icons are registered by default OQ On the standby screen gt to select a shortcut icon then 9 Select lll Creating a shortcut On the screen for which you want to create a shortcut Mew Submenu gt Create shortcut Using Guide Using the Guide enables you to check the operations You can look up the functions without the manual in Japanese only Guide is not available when English is s
187. ocedure Dial lock Omakase Lock Original Lock IC card lock Auto key lock Lock your terminal so that no one can use it Even if you turn the power off Dial lock will not be unlocked If you misplace your FOMA terminal etc you can lock the personal data such as phonebook or IC card function of Osaifu Keitai only by contacting DOCOMO Lock functions that use private information such as mail or phonebook entries to prevent others from viewing or altering these improperly You can lock the IC card functions such as Osaifu Keitai or reception of ToruCa to prevent others from using them without your permission Lock key operations automatically when the FOMA terminal is folded or turned off or no operation is performed for a certain period of time Bro activate e gt Setting Lock Security P Lock pp Enter your security code gt Dial lock fa To deactivate On the dial lock setting screen enter your security code gt 5 consecutive failed entries to release the Dial lock will turn your FOMA terminal off Setting releasing Omakase Lock x9 0120 524 36 Unavailable from part of IP phones My docomo is also available to set release Omakase Lock via PC etc in Japanese only Business hours 24 hours open all year round in Japanese only To activate fe gt setting P Lock Security P Lock Enter your security code pp Select an item in Original lock Raro
188. ommunication Hyper terminal to start Hyper terminal Select the Do not display this message again checkbox and then click Yes Enter any name in the Name column and click OK sample is entered here as an example Select the in use FOMA terminal from Connection method and click OK Click Cancel after the connection screen appears If a COM port of the in use FOMA terminal can be selected When Properties of the COM port is displayed click OK In this example COMG is selected See Checking the COM port p 22 to confirm the actual COM port number to be selected in Connection method If a COM port of the in use FOMA terminal cannot be selected Click Cancel to close the Connection Settings screen and then follow the steps below 1 Select File menu gt Properties 2 Select the in use FOMA terminal in the 2 Connection method column of the Connection Settings tab on the sample sample Properties screen 3 Uncheck 2 Use the Country Region Code and Area Code 4 Click OK 2 e sample
189. or more modems are connected to the PC 2 a When connecting using the FOMA USB Cable il 3 with Charge Function 02 confirm that only the in use FOMA terminal is checked in the V SACS V A Celo E BREUI D Connection method column When connecting wirelessly using Bluetooth SHEER communication confirm that only OHH Modem the name of the in use Bluetooth linked standard modem or Bluetooth modem provided by a Bluetooth device maker is checked in the Connection method column If it is not checked check it FR SISCOBAOSBINCT 1 eT SW Confirm that Use Dial Information is unchecked If it is checked uncheck it This screen is an example of accessing mopera U by packet communication Click the Network SAMPLE tab and set up each setting 28 sais Select PPP Windows 95 98 NT 4 2000 Internet in the I Type of the dial up server to call Select TCP IP Internet Protocol TCP IP in the Use the following items for thi
190. ows XP Open Start All programs Accessories gt Communication New connection wizard When the xf Mn New Connection Wizard screen appears click i RN Next A CRA yg Select Connect to the Internet and click A Next Select Set up the connection manually and click Next Select Connect using a dial up modem and click Next If the F Select the ETTTEm device screen appears select REESI SEERA only the in use FOMA terminal TELS ERO PLP 9 and click Next DERE When connecting wirelessly usi
191. p for a few seconds You can start browser software to view sites and websites or to use e mail When connection is not available check Setting up Dial up Network p 22 and Setting up Dial up 0 30 See p 20 for communication conditions How to disconnect Just closing the Internet browser may not disconnect the communication line Follow the instructions below to disconnect for sure This section describes an example using Windows 7 ap Click the dial up icon in the task tray The connection condition screen for Internet will be displayed e Select the connected item and click Disconnect NOTE The communication speed displayed on the PC may be different from the actual communication speed When this happens Check the followings if you cannot connect to the network or dial up successfully Problem Points to check A FOMA terminal is not Check if your PC satisfies the required operating environment p 4 recognized by the PC Check if the FOMA terminal is connected to the PC and the power is turned on When using the FOMA USB Cable with Charge Function 02 optional Check if the FOMA communication setting file drivers is installed Check if the FOMA USB Cable with Charge Function 02 optional is firmly connected Check if the USB mode p 7 is set to Communication mode When using Bluetooth communication Check if the Bluetooth device is connected to the FOMA terminal via dia
192. play surface may be stained if moisture or dirt is left on it for a long period Never use chemicals such as alcohol thinners benzene or detergents as these agents may erase the printing on the FOMA terminal or cause discoloration e Occasionally clean the connection terminals with a dry cotton swab etc Soiled connectors may result in poor connections loss of power or incomplete charging Wipe with dry cloth or cotton swab When cleaning take care not to damage connectors e Do not place the FOMA terminal near an air conditioning vent Condensation may form due to rapid changes in temperature and this may cause internal corrosion and malfunction Do not put excessive pressure on the FOMA terminal or battery pack Do not put the FOMA terminal in a bag filled with many objects or sit down with it in a hip pocket Excessive pressure may result in malfunction or damage to the display internal circuit or the battery pack etc Also if an external device is connected to the external connector terminal earphone microphone terminal excessive pressure may result in malfunction or damage to the connector Do not scratch the display with metallic objects Doing so may cause scratches malfunction or damage Carefully read the manuals supplied with each of the options Handling the FOMA Terminal Avoid using the FOMA terminal in extremely high or low temperatures The ambient temperature of the room should be 5 C to 35
193. r When the User Account Control screen appears click Yes For Windows Vista Select Device Manager When the User Account Control screen appears click Continue For Windows XP Click the Hardware tab and click Device manager Click each device to check the modem name and the COM port number The modem name and the COM port number are displayed under COM LPT Ports COM amp LPT and EF A Modem Stopping the dial up connection standby Stop the dial up connection service being connected o MENU key Tool Bluetooth Device list Uncheck Dial up P Press a key corresponding to Finish 13 Connecting to a Wi Fi compatible PC Packet communication is possible by setting the FOMA terminal as an access point and connecting the FOMA terminal and a Wi Fi compatible PC via Wi Fi Set the FOMA terminal to Access point mode beforehand Refer to the Instruction Manual for the FOMA terminal for how to set to Access point mode and details for Access point mode settings lt Example For Windows 7 gt o Open O gt Control Panel Select Network and Internet gt Show network status and task Click
194. r downward Display the Search phonebook menu screen Activate shortcut 9 Left Right key Move the cursor to the left or right Activate MyFACE OK key Perform the function displayed on this key lew key Display the main menu key Ce Display the still image shooting screen key isplay the mail menu j key Display the iMenu cLR Back Clear i channel key Return to the previous step or delete the entered characters Display i channel D Start key Make calls Power End Hold key p Dial keys Enter phone numbers or characters 9 CX J Public mode Drive mode key Set Public mode Drive mode D 3 J Manner key UO m 9 OG Quick key Activate a function selected in Quick button set Multi key Display the TASK MENU screen Mouthpiece Microphone Charging terminal Strap hole External connector terminal Multi terminal for charging connecting an earphone etc Connect AC Adapter optional DC Adapter optional FOMA USB Cable with Charge Function 02 optional or Stereo Earphone Microphone 01 optional etc E 7 Volume up key Raise the earpiece volume or set Manner mode Volume down key Lower the earpiece volume Mlumination Charge lamp Recording indicator Sub display Display the clock or FOMA terminal status 2 mark Read the IC card and make iC transmis
195. r more details contact the Ministry of Economy Trade and Industry METI 97 Intellectual Property Right hi Copyrights and portrait rights Except for personal use subscribers are prohibited from copying modifying or distributing content such as photos taken with the FOMA terminal or text music software downloaded from Internet websites whose copyrights belong to third parties without the permission of the copyright holder Capturing or recording a stage performance entertainment or exhibition may be prohibited even if it is for personal use Taking a photo of someone using the FOMA terminal without consent or posting it on a website without consent may infringe the right of portrait LA sp FOMA i mode i appli i motion Deco mail Chara den ToruCa WORLD CALL DCMX j area WORLD WING 2in1 and iC logo are trademarks or registered trademarks of NTT DOCOMO INC Catch Phone Call waiting service is a registered trademark of Nippon Telegraph and Telephone Corporation McAfee is a registered trademark or trademark of McAfee Inc or its subsidiaries in the United States and other countries Rovi G GUIDE G GUIDE MOBILE and G Guide related logos are trademarks or registered trademarks of Rovi Corporation and or its subsidiaries in Japan Powered by JBlend Copyright 2002 2013 Aplix Corporation All rights reserved JBlend and JBlend related trademarks are tradem
196. r socket when the adapter will be left unused for a long period Failure to observe this precaution may cause fire burns or electric shock e Unplu Q If water or other liquid gets into the adapter immediately unplug it from the power outlet or cigarette lighter socket Failure to observe this precaution may cause fire burns or electric shock e Unplug Unplug the adapter from the power outlet or cigarette lighter socket before cleaning it Failure to observe this precaution may cause fire burns or electric shock e Unplug GEN A caution EE Be careful with sharp edges when removing the miniUIM Sharp edges may cause injury Do Do GE A WARNiNc ENS Anyone with an electronic medical device such as an implanted pacemaker or ICD should use or carry the FOMA terminal at least 15 cm from the site of implantation Radio waves from the FOMA terminal can adversely affect electronic medical devices Electronic medical devices other than implanted pacemakers and ICDs may also be used outside hospitals Users of electronic medical devices are advised to ask the manufacturer whether these instruments can be affected by radio waves Radio waves from the FOMA terminal can adversely affect electronic medical devices o External chassis Display Battery pack storage side hinge panel uc c OD Do Polycarbonate resin If there is a chance that the distance from
197. s SCRI SE SR SERIE c Sb SEE NA D BI Ned s EUR p Kod SS A ed m ES SH g Fiat 6 TNE E SE a 3m ii J jm Ht 2X ish ju B A 3 29 JI LEE E BS E 78 A TA A ith iad 7 7 im Wh SEG GEH E i IR E eA HM AR XR Hm T 2 2 if E mop EK ili A 3 A m 7 A E 3B I 78 ES 7E ig is a X ELE JE iat oR BR ie SR m if aE AR BK mi BS BE i iz H iE ihe m HR A A Li i eae 2 s iF M Ep z HE EER A E HE BSA JA E E a UR Jm ie b K D m8 KBE A Ea Pee mm zx uy WEEDS Ux Vat Se Sasa St PU EN HE TXNHF HI whet hii FH HO EE Sap HE RR Sal Su ail e SEHR Sil ib Gia NI He sb LLL RE REPRE ns m E JR XU SEE SE d Sb e Er RAE et Ma AES at Fs sad A SEB ta aH DS Sar OES alle St HS SAS StS DDR OQ ep aa BH Sm SSE EME DE SHS A Sa Y H rrr d He SAS a HES as EGO SHE caps ES el ET Rt 908 Ad AN ns PS SAY Ha 8 do inb CT cobs ER DS m t Sie Sas a Ut dr II OUI i 1 CHA d FS SERE SEES qi el TS Boat h Ten es Hh 7 E A AN TENI Sal QT BRE 058 E 2 eB SERICO RR SE W SE SDE SE LT PU EST D RI Se E RI i e ADE RE WERL TI d s d SR S Sp SS NADY ME LR in ERE p Sr Sr IE En Se 2 Y sh Sd AR S DEC do FE ars Rt al BERI ax cht ar AH aie Hl D PH B at DD TE ai M E 4 it S S Hit Ba niea p Ei QOH dlls gt V a sm FF gt ol dis Gi a Hi Ei SE RS i abr are ad a ARAPA F Aeh
198. s automatically 0 ll To release the setting 215250 Using various network services Available network services Useful DOCOMO network services are available The network services are not available when you are outside the service area or in a place where the signal is weak For details refer to NTT DOCOMO website For the application and inquiries please contact General Inquiries on the back cover of this manual Service name Monthly charge Voice Mail Service Charged Missed call notice service Free Call Waiting Charged Call Forwarding Service Free Nuisance Call Blocking Free Caller ID Notification Free Caller ID Request Free English Guidance Free Multi Number Charged 2in1 Charged Public mode Drive mode Free Public mode Power OFF Free Melody call Charged Koe no Takuhaibin Free rend TEL function Voice mail service Select an item key TEL function Other network serv Call waiting Select an item key TEL function Other network serv Call forwarding Select an item Emergency call Emergency call Phone number Police emergenc 110 Fire brigade Ambulance emergenc 119 Maritime distress call 118 Your FOMA terminal supports Emergency Location Report Calls made to emergency service organizations e g by dialing 110 119 or 118 disclose information on the caller s location to the organization receiving the call The location information may not be correctly sent dependin
199. s connection Since the setting of QoS QoS Packet Scheduler cannot be changed leave it as it is Pod VAR ILD RI ea eer EOI E o M ind hy OR rt LEU Aa OE Microsoft 15 Click Settings 16 Clear all the boxes and click OK BATON REA N CE Ces 39 17 When the Step 14 screen reappears click OK Running dial up connection This section describes how to make a dial up connection for packet communication by using the dial up setting lt Example Using the FOMA USB Cable with Charge Function 02 on Windows 7 gt Connect the FOMA terminal to the PC with the FOMA USB Cable with Charge Function 02 optional Open gt Control Panel Connect to Internet For Windows 8 From the Start screen open the Desktop and then move the mouse cursor to the top right corner of the screen to display the Charm Bar gt Click Settings Control Panel
200. s uplink is available in the FOMA HIGH SPEED area Communication is provided on a best effort basis Communication speed varies depending on the communication environment or network congestion This is suitable for exchanging small amount of data at high speed You can also access a corporate LAN connected to the FOMA network Use an access point that supports FOMA packet communication such as DOCOMO Internet connection service mopera U For packet communication connect the FOMA terminal to a PC using FOMA USB Cable with Charge Function 02 optional Bluetooth communication or Wi Fi connection or to a PDA using a dedicated cable 1 Note that the communication charge can become very expensive when large files are sent and received 2 Itis the maximum value on the technical standards and the actual communication speed varies depending on the network congestion or communication environment The communication speed may be lower when you are out of the FOMA HIGH SPEED area you connect to the access point to which the HIGH SPEED service is not supported 8 When connecting using Bluetooth communication the FOMA terminal communication speed will be that of HIGH SPEED service But communication at the maximum speed may not be possible due to Bluetooth communication speed limitation F
201. send one data item Example To send one phonebook data On the screen of the data to send Submenu the center P Send data gt Send Ir data O Direct the infrared data port toward the infrared data port of the other party s devices gt YES ll To receive one data item Ww P Tool P Receive Ir data Receive gt Direct the infrared data port toward the infrared data port of the other party s device P Upon completion of reception YES Infrared data port 77 Sending receiving data by iC transmission iC transmission is a function that allows you to send or receive data such as phonebook entries to or from other FOMA terminals just by overlapping the FOMA terminals You may not be able to transfer data depending on the other party s device E To send one data item Example To send one phonebook data On the screen of the data to send le Submenu gt Send data gt iC transmission O Put your 4 mark close to the other party s FOMA A terminal gt YES li To receive one data item 3 Put your 2 mark close to the other party s FOMA terminal Perform data transmission on the other party s FOMA terminal Connecting to a PC You can transfer WMA data images etc to from a microSD card by connecting the FOMA terminal to a PC Also you can perform data communication by accessing to Internet An See The FOMA USB Cable with Charge Function 02 optional or FOMA
202. service lets you check if your FOMA terminal s i mode is working correctly for operations such as sending receiving mail and downloading images ring tones When there seems to be a malfunction as a result of checking please contact Repairs on the back cover of this manual in Japanese only lll Connecting to i mode fault diagnosis site Japanese a gt User support gt Inquiries gt Inquiries for fault signal quality gt i mode fault diagnosis ME Charges will apply if using the service overseas QR code to access the site Updating software This function establishes a network connection and checks whether the FOMA terminal software needs to be updated If update is required this function downloads a part of software by packet communication and then updates the software When software update is required the information can be viewed on the NTT DOCOMO websites or in User support in Japanese only of iMenu Software may be updated in the following three methods Auto update Now update and Reserved update It is possible to perform software updates while keeping your Phonebook entries camera images downloaded data and other data saved on the FOMA terminal intact However note that in some cases data cannot be protected depending on the condit
203. sions FOMA antenna The antenna is built in Covering the antenna part with your hand may affect the quality Camera Infrared data port Speaker monaural microSD card slot inside Back cover To ensure that you use your FOMA terminal correctly read Precautions carefully before use Keep this manual after reading for future reference The precautions must be observed at all times since they contain information intended to prevent the bodily injury or damage to property The following symbols indicate the different degrees of injury and damage that may occur if the information provided is not observed and the FOMA terminal is used incorrectly Indicates that death or serious bodily injury may result directly and immediately from improper use Indicates that death or serious bodily injury may result from improper use Indicates that slight bodily injury and or damage to the property may result from improper use B The following symbols indicate specific directions Indicates that it is prohibited Indicates that it must not be disassembled No disassembly Indicates that it must not be used near water which means that you must not let it become wet ga x 2 a No liquids Indicates that you must not touch it with wet hands No wet hands DO OU awe LE Don t Don t ty i Indicates that it is an instruction based compulsory conduct must be acted Indicat
204. the COM port of the scoves 572 Jeans Access point column of the in 4 esiscariencoesoo use FOMA terminal and click OK Era m When connecting wirelessly using Bluetooth BID MEN communication confirm the COM port number of the in use Bluetooth linked standard modem or Bluetooth modem provided by a Bluetooth device maker in the Access point column The COM port confirmed here will be used in the access point APN set up p 26 EHD VC BUBRCRO P The contents displayed on the screen and the COM port number differ depending on the PC BFA To check the COM port on Windows XP Open A9 P Star s aerae Control Panel e Windows XP E HED PQ EE HF Ga PUY BE FAX Qa v4 Q9 H j2 P gt 37 RI 2 09770 o 24 Open sem E RRO RTV D APH Telephone and modem options Or OB Pr rm m from FELT d mean Doo Messe hardware in Control Panel acm
205. the mouse cursor to the top right corner of the screen to display the Charm Bar Select Settings gt Control Panel Open Device and printer Right click the in use FOMA terminal model name and select EF LORS Modem settings If the Address information screen is displayed enter Area code and click OK 22 Click the Modem tab to confirm the COM port of the pera ma il E Access point column of thein amp ios seen use FOMA terminal and click OK When connecting wirelessly using Bluetooth communication confirm the COM port number roma of the in use Bluetooth linked standard modem or Bluetooth modem provided by a Bluetooth device maker in the Access point column The COM port confirmed here will be used in the access point APN set up p 26 The contents displayed on the screen and the COM port number differ depending on the PC D OHER 7074 A To check the COM port on Windows 7 Gp Open gt Control Panel e Open Device and printer in Control Panel
206. tions such as a bathroom Doing so may cause fire burns or electric shock The DC adapter must be used only in vehicles with a negative ground Do not use the adapter in vehicles with a positive ground Doing so may cause fire burns or electric shock Dont Don t Dont Do not touch the adapter when you see lightning or hear thunder Doing so may cause electric shock Do not short circuit the charging terminals when the adapter is plugged into the power outlet or cigarette lighter socket Also do not let the charging terminals contact with your body hand finger etc Doing so may cause fire burns or electric shock Do not put heavy objects on the power cord of the adapter Doing so may cause fire burns or electric shock et ct o a a 10 When plugging unplugging the AC adapter into from the power outlet make sure that no metallic straps or other metallic objects are caught between the plug and the socket Metallic objects may cause fire burns or electric shock Dont Do not apply excessive force to the top bottom left or right while the adapter is connected to the FOMA terminal Doing so may cause fire burns injury or electric shock Dont Do not touch the power cord of the adapter charging terminals desktop holder or the power outlet with wet hands Doing so may cause fire burns or electric shock SN e
207. to use another operator s SIM card CONTRIBUTORS BE LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES 100 LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE This product is equipped with NetFront DTV Profile Wireless Edition of ACCESS CO LTD as data broadcast BML browser This product employs Media Media colon of ACCESS CO LTD as broadcast content start information Copyright 1996 2013 ACCESS CO LTD ACCESS NetFront and Media Media colon are trademarks or registered trademarks of ACCESS CO LTD in Japan and or other countries Frame rate enhancement function uses FrameSolid technology by Morpho Inc FrameSolid is a trademark of Morpho Inc This product employs GestureTek technologies Copyright 2006 2013 GestureTek Inc All Rights Reserved Primeworks catalyst mobile OATR Trek Co Ltd SIM lock can be removed at any docomo Shop An unlocking fee is charged Certain services and features might be disabled when another operator s SIM card is used Please be aware that DOCOMO does not under any circumstances guarantee operation For details of SI
208. tu vip rc abc 35 Viewing main DRIBEYULss usando rnes totom etra terae 26 Manner mode Setting ccscccsscsssssssscsscssccssseees 34 Map sate 60 Material TSE e risani 11 Menuilist ests seesceiesrn ria seas se 88 microSD card Insert Remove a aaa aaa snusar rastaaar eastessastesstanees renee 75 Ue 73 miniUIM Attac OPE 20 Hadling iss nime Pom Umen d ndn anie 14 Missed info acerca expe tr Y PARERE E TYYE TER E SUNERUA 37 MOV E m 69 Movie Camera PR PPP 62 Music Play music NSK 66 MUSIC VII M 67 Mute keypad sound e rsa sss sass sass a snes 34 Network security code eere 38 Network service ee saas rasa ee eere eere eee rne enu 46 Omakase LO au oisesi bti in hes pere PIN Reuse 40 Options and related devices 87 Original LO 40 Osaifu Keitai Osaifu Keital TETTE TD 70 LEOIA E 70 Overseas use sae 48 Own number display KR 23 Part names and functions eere 3 Pattern data update eseessesecescescescesscescesceseceseee 85 Phone Make a call by entering the phone number 43 Make a call from phonebook 43 Make a call from redial received calls 43 Make an international call 44 Overseas USB re ode a i be
209. tus Result CBC lt bcs gt lt bcl gt AT CBC of the FOMA terminal bcs CBC 0 70 O FOMA terminal is powered by the battery OK 1 FOMA terminal is not powered by the battery AT CBC 2 FOMA terminal is not connected to the battery ERROR 3 FOMA terminal is out of transmission due to AT CBC the power supply error CBC 0 3 0 100 bel OK O Battery has run out or battery is not connected 1 100 Battery remained AT CBST Changes the bearer service Format AT CBST lt gt 1 0 AT CBST 134 1 0 type 1 116 64 000bps bit transparent initial OK value AT CBST 1 134 64 000bps multimedia CBST 134 1 0 OK AT CBST CBST 116 134 1 0 amp F amp W OK AT CDIP 77 Sets whether to notify the 7 0 Not notify the called sub address AT CDIP 0 called sub address for the initial value OK incoming call Inquires for n 1 Notify the called sub address Multi number subscription AT CDIP AT CDIP Displays the current setting CDIP 0 1 CDIP 7 OK 112 0 You do not subscribe to Multi number 777 1 You subscribe to Multi number amp F amp W m 2 Unknown AT CEER Displays the reason for Result CEER lt report gt AT CEER disconnection of the report List of disconnection reasons p 55 CEER 36 previous call OK AT CGDCONT Sets the access point name p 52 p 52 APN for packet origination AT CGEQMIN Registers a criterion to be used p 52 p 52 to decide whether or not to allow the QoS qualit
210. u Uta Full are registered trademarks of Sony Music Entertainment Japan Inc Adjusting volume of ring tone y Adjusting the volume of calls he gt Setting Sound Vib Manner Ring volume gt Phone gt to adjust the volume then Set Setting vibrator J hi Informing you of incoming calls by vibration Fw gt Setting Sound Vib Manner Vibrator setting gt Phone Select a vibration pattern 33 Using manner mode Set the FOMA terminal not to play ring tones or keypad sound through the speaker with a single key operation Even in manner mode the camera shutter sound the auto focus lock sound or the start end pause sound of a moving picture recording or a voice recorder plays On the standby screen 1 second or longer appears on the standby screen ll To release the setting On the standby screen 1 second or longer Co ue O Ss D w oO EJ Setting keypad sound OFF he Setting Sound Vib Manner pp Other sound setting Keypad sound OFF Changing screen setting hi Changing standby display Q y Setting Screen Display Stand by display Stand by display Select an image hi Changing display brightness Set the backlight behavior of the display or keys and adjust the brightness le Setting gt Backlight Illum pp Backlight
211. up a dial up connection for packet communication 64K data communication without using DOCOMO Connection Manager The flow of operation is described below it is unnecessary to set up the dial up network for 64K data communication Go on to Setting up Dial up p 30 About AT commands AT commands are commands for modem control The FOMA terminal complies AT commands and supports some enhanced commands and its own AT commands Q Entering an AT command allows you to set or confirm display the detail settings and the contents of the settings for the Data communication and FOMA terminal Checking the COM port To set up the access point APN you need to specify the COM port number assigned to FOMA model name Modem built in after installing the FOMA communication setting file drivers This section describes how to confirm the COM port number The COM port confirmed here will be used in the access point APN set up p 26 Preparation This section takes the setting using the FOMA USB Cable with Charge Function 02 for example When you connect using Bluetooth communication see p 12 Connect the FOMA USB Cable with Charge Function 02 optional to the FOMA terminal Turn on the FOMA terminal then connect the FOMA USB Cable with Charge Function 02 connected to the FOMA terminal to your PC To check the COM port on Windows 8 From the Start screen open the Desktop and then move
212. ution of 1 024 X 600 dots or High Color 65 536 colors or better is better 1 024 X 768 dots or better is recommended recommended High Color 65 536 colors or better os Windows XP Japanese version Windows XP Home Edition SP3 or later Windows Vista 32 bit 64 bit Japanese Japanese version version Windows XP Professional SP3 or later Windows 7 32 bit 64 bit Japanese version Japanese version Windows 8 32 bit 64 bit Japanese version Windows Vista SP1 or later 32 bit 64 bit Japanese version Windows 7 32 bit 64 bit Japanese version Windows 8 32 bit 64 bit Japanese version Recommended environment for your OS Required memory Windows XP 128MB or higher Windows Vista 512MB or higher Windows 7 32 bit 1GB or higher Windows 7 64 bit 2GB or higher Windows 8 32 bit 1GB or higher Windows 8 64 bit 2GB or higher 5MB or higher e e e e e XL X He ec 10MB or higher Internet Explorer 6 0 or later Windows Mail Outlook Express 6 0 Hard disk space Web browser Mail software 1 The proper operations on the upgraded added or modified OS are not guaranteed 2 The required memory and necessary hard disk space may differ depending on the PC s system configuration For the latest information on the operating environment visit the DOCOMO website This FOMA terminal is not compatible with Remote Wakeup function This FOMA terminal is not compatible with the FAX commu
213. ved calls On Redial Received calls screen Submenu gt Add to phonebook Phone or UIM New Enter each item then GJ Finish Editing phonebook entries You can add or edit information in the phonebook such as phone numbers or mail diee y Editing FOMA terminal phonebook entries On Phonebook detail screen lew Submenu Edit Add or edit entries Finish gt YES Deleting phonebook entries on Phonebook detail screen lew Submenu gt Delete Select an item pp YES 55 o6 i mode Full Browser You can use online services such as i mode site connection accessing to Internet i mode mail with i mode by using display of i mode compatible terminal e i mode requires a subscription and is a fee based service For details on i mode refer to NTT DOCOMO website Information on i mode menu sites and Internet websites is generally protected by copyright law Text and images downloaded from these sites to i mode compatible terminals should be for personal use only and cannot be sold or redistributed in part or as a whole in their original or a modified form without the copyright holder s permission e Ifthe miniUIM is replaced or the power is turned on with no miniUIM inserted you cannot display play images movies and melodies downloaded from sites files attached to mail images movies melodies etc Screen memo and Message R F e Ifa file whose
214. xecution example Only the following 4 patterns can be set 1 is set as an initial value to each cid 1 Command for permitting all speeds of both uplink and downlink when cid is 5 AT CGEQMIN 5 OK 2 Command for permitting only the speed of uplink 5 760kbps and downlink 7 232kbps when cid is 6 AT CGEQMIN 6 5760 7232 OK 3 Command for permitting uplink 5 760kbps and all speeds of downlink when cid is 7 AT CGEQMIN 7 5760 OK 4 Command for permitting all soeeds of uplink and only 7 232kbps of downlink when cid is 8 AT CGEQMIN 8 7232 OK ll Command name CGEQREQ parameter Outline Sets the QoS quality of service to be requested to network when originating a PPP packet communication For setting only the following pattern in the command execution example can be set which is also set as an initial value Though this command is a setting command it will not be recorded in non volatile memory written by amp W nor reset by amp F or Z Format CGEQREQ lt cid gt Explanation of the parameters cid 1 to 10 i Cid is a number for managing the access point name APN registered in the FOMA terminal for a packet communication Operation performed when the parameter is omitted CGEQREQ Sets the initial value to all cid CGEQREQ lt cid gt Sets the specified cid to the initial value CGEQREQ Displays a list of values that can be set CGEQREQ Displays the current setting
215. y of service that is informed from the network side when PPP packet communication is established AT CGEQREQ Sets the QoS quality of p 53 p 53 service to be requested to network when originating a PPP packet communication AT CGMR Displays the version of the AT CGMR FOMA terminal 12345 000000000XX OK AT CGREG 27 Specifies whether to notify 11 0 Not informed initial value AT CGREG 1 the network registration 7 1 Informed OK Set to informed condition Informed when switching between AT CGREG The returned notification Inside the service area and Outside CGREG 1 0 displays whether you are the service area is completed OK inside or out of service AT CGREG AT CGREG Displays the current setting toti OK CGREG lt gt stat Outside the service area fn Set value stat hen you move from 0 Out of packet area e the service 1 Within packet area area to inside the 4 Unknown service area amp F amp W 5 Within packet area CGREG 1 AT CGSN Displays the product number AT CGSN of the FOMA terminal 12345 00000000XXX OK 44 AT command Outline Parameter description Command execution example AT CLIP 77 Displays the other party s 7 0 Not display the result initial value AT CLIP 0 Caller ID on a PC when a 7 1 Display the result OK 64K data communication call is received AT CLIP AT CLIP Displays the current setting CLIP 0 1 CLIP 72 7 OK m 0 NW setting