Wireless Solutions in your Hand User`s Manual
Contents
1. andyPort Serial 0000000000000909090 Wireless Solutions in your Hand User s Manual UK Europe USA Office Tel 44 0 8700 434040 Fax 44 0 8700 434045 E mails info omniinstruments co uk 120 122 King Street Broughty Ferry Dundee Scotland UK DD5 1EW Measurement gt Control gt Data Acquisition Web Site www omniinstruments co uk Australia Asia Pacific Office Tel 61 0 894 888 960 Fax 61 0 894 888 965 info omniinstruments com au PO Box 105 Leederville Western Australia 6902 1 2 3 Table of Contents INTRODUCTION viere ai hice des canciones 3 Eie LEE AT UREA he tat da re tet Shae eee a dg sehr ate e e dase 3 ded PACKAGE T EE A T 3 SPECIFICATIONS icsicecossece OS 4 ZA GENERAL to uh ee hea A aS Aad ee eee ee eae ee ee a esa 4 2 26 ARS 232 INTERFACE sneri A handed dd dd bd id 5 LANA A Tose Sew aaa aed Nea aa Hise hen es asd een ee Se ee Na 5 2 22 El ARA id pe eae tan pi ee a eR ea Eas 5 20 FACTORY SETTING on di 5 24 DISPLAY STATUS o di cd dd nde tae 6 2 02 SRESET BUNION cauto iria 6 2 5 1 Enter Configuration MOTO eri A EA T rca 6 2 5 2 Exit Configuration Mod pesee aaa ai a AER i d i ikea E 6 PS O A a E PA IE E A AETS 6 HARDWARE INSTALLATION cccccseeeeeeeeseeeeeeseeeeeeeseeeeeenseceeeeeesseeeeeeseeeeesnsseeeesesseeeneeseseenens 7 3 1 HARDWARE DESCRIPTION cccceeeeeeeeee paces un KAA ER AE a A TNA NE 7 3 23 POWER SUBA a E A E E A EA 7 Iae INSTALL PROCEDURE cust
2. d local device as follows Change a PIN for remote at the local gt Apply it gt Change a PIN for local and apply it Remarks3 Once you change a connecting address and connection mode for the remote the local device won t be able to make a connection to the remote device 10
3. gt Set a remote device A local and remote address address for a wireless BD_ADDR always need to connection be difference 2 Baud rate BBaud Rate Change the baud rate Baud Rate 0 1200 1 2400 2 4800 3 9600 4 19200 5 38400 6 57600 7 115200 3 COM port CCOM Port This is only valid in connection mode 2 4 PIN code EPIN lt Enter gt Authentication Off Type lt Enter gt Paired adapters should Authentication On Type up to 11 characters have a same PIN code 5 Flow control FFlow Control Set the Flow control 0 None 1 DTR DSR 3 Hardware amp DTR DSR Hardware 2 6 Connection Mmode Set a connection mode 0 1 1 Mode 1 WAIT Mode mode 2 REGISTER and CONNECT Mode 7 Friendly name Nname lt Enter gt Set a friendly name up to 11 characters 8 Command for O Enter configuration mode the remote for the remote 9 Parity Bit Pparity Set the parity bit 0 None 1 Odd 2 Even 10 Stop Bit Sstop Set the stop bit 0 1 Stop 1 2 Stop 11 View V Display configuration information 12 Exit X Apply changes 13 Usage Print the usage Waning If you push the RST button the COM port of HPS 120 will be stored the factory setting 4 3 2 Command List for Remote Device To change the configuration for a remote device via over the air firstly you have to use a command O at the local device The following are a procedure for changing configurat
4. ion of remote device via over the air e Configure a remote device at the local device O Save changes at the local device e Make a connection between the local device and remote device Automatically Send changes from the local device to the remote device Automatically Apply changes at the remote device and reboot Automatically Item Syntax Description Remarks 1 Connecting AAddr lt Enter gt Set a connecting address for address remote device 2 Baud rate BBaud Rate Change the baud rate for the remote 3 COM port CCOM Port This is only valid in mode 2 4 PIN code EPIN lt Enter gt Authentication Off Type lt Enter gt Paired adapters should Authentication On Type up to 11 characters have a same PIN code 5 Flow control FFlow Control Set the Flow control for remote 6 Connection MMode Set a connection mode for mode remote 7 Friendly name NName lt Enter gt Set a friendly name upto 11 characters for remote 8 Parity Bit PParity Set the parity bit 0 None 1 Odd 2 Even 9 Stop Bit SStop Set the stop bit 0 1 Stop 1 2 Stop 10 View V Display configuration information for remote 11 Exit X Save changes and return to main menu 12 Usage Print the usage Remarks1 To configure a remote device via over the air a local device must be able to make a connection to the remote device Remarks2 You can change a PIN code for the remote an
5. mend above 2 4kbps Supports 1 2 2 4 4 8 9 6 19 2 38 4 57 6 115 2kbps Coverage Up to 100 M Connection Point to Point Signal DCD TxD RxD GND CTS DSR DTR RTS RS 232 Interface D_SUB 9 Pin Female Standard Bluetooth Specification Version 1 1 Frequency 2 400 2 4835GHz Hopping 1 600 Sec 1MHz Channel Space Modulation GFSK 1Mbps 0 5BT Gaussian Tx Power Max 20 Typical 16dBm Class 1 Rx Sensitivity 84dBm Antenna Interface SMA Female Antenna Gain Max 2dBi Power Supply 5 12Vdc Current Max 110mA Consumption Operation 20 75 C Temperature Size 35mm W x 65mm D x 16mm H Remark1 The default hardware configuration is for using CTS If you want to se DSR please contact us 2 2 RS 232 Interface 2 2 1 Pin out 5 4 3 2 1 ee ee ENE es E 9 8 7 6 2 2 2 Signals Pin Number Signal Direction Description 1 DCD Output Data Carrier Detect 2 TxD Output Transmitted Data 3 RxD Input Received Data 4 DSR N A Input Option Data Set Ready 2 5 GND N A Signal Ground 6 DTR Output Data Terminal Ready 7 CTS Input Clear to Send 8 RTS Output Request to Send 9 Vcc Input Power Supply Remark1 The default hardware configuration is for using CTS If you want to use DSR please contact us 2 3 Factory Setting The following is the factory setting of COM port e Baud rate 9600 bps Data Bit 8 bit Parit
6. odiada dida 7 USAGE E E E aa 8 4 1 HYPER TERMINAL SETTINGS cooonncccccnnononcnnnonnncnnnnn cnn cnn r eaa EE E A LENAR REN rr 8 4 2 CONFIGURATION nan a adores A eee A eae 8 424 Start COnNGUIATION ci e ETE 8 l2 Usage PNUD italia defences a tb A Pees dvsness 8 4 2 3 Aller CONTIGQUIATION cia di rta 8 AI COMMAND SET asait aces o eae aaa eek kaa E E 9 4 3 1 Command List for Local DoviC E asrerrreriir i reni narine EEE EE TETERE EEO AEE A 9 4 3 2 Command List for Remote DeviCe ooooooociciniccnnnnncocnnonoconnnnnnnnnn nn nan n cnn nana narran nn l 10 1 Introduction Thank you for purchasing a HandyPort Serial The HandyPort Serial can be used as a component in many types of systems allowing them to communicate wirelessly with other Bluetooth products such as PC cards laptops handheld computers mobile phones and other HandyPort Serial The HandyPort Serial is a suitable component in new products as well as in existing products 1 1 Features Supports Bluetooth Serial Port Profile and Generic Access Profile No need of external host and software Easy of installation and use Supports configuration of the local device Supports configuration ofthe remote device via Over the Air Easy of maintenance Supports up to 100 meter Line of Sight 1 2 Package HPS 120 2 EA Antenna 2 EA A USB Cable for Power Supply A Manual 2 Specifications 2 1 General Baud Rate Up to 115 2kbps Recom
7. ply power to the HPS 120 as follows Use an AC DC converter Output Power 5 12Vdc 300mA Use a provided USB cable You can supply power via 9 pin of D_SUB 9 Pin connector 3 3 Install Procedure Step 1 Assemble a provided antenna to HPS 120 body Step 2 Plug a HPS 120 into the COM port of device Step 3 Power on Step 4 Configure the HPS 120 if necessary 4 Usage You can change the configuration of HPS 120 using Hyper Terminal 4 1 Hyper Terminal Settings Baud Rate 9600 bps Data Bit 8 Parity Bit None Stop Bit 1 Flow Control None Emulation VT 100 4 2 Configuration 4 2 1 Start Configuration Step 1 Plug a HPS 120 into a COM port of PC And Power it on Step 2 Open a Hyper Terminal and set it up Step 3 Push the RST button on HPS 120 If you enter the configuration mode successfully LNK LED will be flashing every second Step 4 Hit the lt Enter gt key 5 second later Step 5 Change the configuration of HPS 120 with commanas if necessary 4 2 2 Usage Printing If you are in the configuration mode type key You will see the usage All commands and parameters are case sensitive And you cannot use a lt Backspace gt 4 2 3 After Configuration After finishing the configuration you have to execute a command X to apply changes 4 3 Command Set 4 3 1 Command List for Local Device Item Syntax Description Remarks 1 Connecting AAddr lt Enter
8. y Bit No parity Stop Bit 1 stop bit Flow control None 2 4 Display Status The following is status LED information e OPR Red When HPS 120 is powered on it is turned on or flashing eo LNK Green When a wireless link is on it is turned on If HPS 120 is in the configuration mode it will be flashing every second 2 5 Reset Button The RST button has the following functions e Enter Exit the configuration mode e Restore the factory settings e Disconnect and reconnect a wireless connection 2 5 1 Enter Configuration Mode When the LNK LED is OFF push the RST button When the LNK LED is ON you have to push the RST button twice to enter the configuration mode If you enter the configuration mode successfully LNK LED will be flashing every second And HPS 120 COM port will be stored the factory settings 2 5 2 Exit Configuration Mode You can have two options to exit the configuration mode Exit the configuration mode by software Type X Exit the configuration mode by the RST button Push the RST button 2 5 3 Re connection When the LNK LED is on you can push the RST button to disconnect and reconnect a wireless link Waning If you push the RST button the COM port of HPS 120 will be stored the factory setting 3 Hardware Installation 3 1 Hardware Description RST Button RS 232 Connector OPR LED USB Cable for Power Antenna Connector 3 2 Power Supply You can sup
Download Pdf Manuals
Related Search
Related Contents
CREME FR User Manual for the HH2 Samsung GT-S5301 Korisničko uputstvo Ad Hoc: Using Session Parameters - Logi DevNet User Manual - Cafe Coffee Day Peavey SP 4Ti User's Manual 5-phase stepping motor unit CRK Series Built-in Model 3505 pH/mV/Temperature Meter Operating Manual Copyright © All rights reserved.