1. annnnnnnnrnannnnrvnnnnannnnnnannnnnnannnannnnrnannnnnnnnnnnne T 4 Card FSM aars Ten 8 TT EROII ee E A E ES 8 2 BEUN eee E E 10 4 3 GeoFinger on Service arrnrarrnannnnanrnnnnnvanennnrrnanrnnannnanennanenanennnsnnanennannnunennnennnennn 11 5 Connecting an Alarm Device re 12 EE I EEE EE 13 ETNE 14 Regulatory Notices Regulatory Notices NICAT Ka Oy us FCC Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment Class A This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense C I CE Notice This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures RoHS RoHS Compliance The Restriction of Hazardous Substances RoHS Directive is to forbid the use of hazardous materials of production To meet the RoHS Directive requirements this product is made to be RoH
2. C GeoUision The Vision of Security GeoFinger User s Manual ETTE So ee Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use GeoVision 2009 GeoVision Inc All rights reserved Under the copyright laws this manual may not be copied in whole or in part without the written consent of GeoVision Every effort has been made to ensure that the information in this manual is accurate GeoVision is not responsible for printing or clerical errors GeoVision Inc OF No 246 Sec 1 Neihu Rd Neihu District Taipei Taiwan Tel 886 2 8797 8377 Fax 886 2 8797 8335 http www geovision com tw Trademarks used in this manual GeoVision the GeoVision logo and GV series products are trademarks of GeoVision Inc Windows and Windows XP are registered trademarks of Microsoft Corporation October 2009 Contents PoU OY NOD EE NE 1 Caution arannnvennnnenvnnennnnenvennnnenennennnnennnneneennnnnnnnnennnnennnnenennnnnnnenvenenuenennene 2 LL MN 3 tl PENGE Napanee eset asin E E E E ve EO 4 2 Connecting GV AS Controller r arrrrrnarrarnnnrnnrnanvanrnnrnnrnnnnnnnnnnnnsnnnee 5 2 1 Connecting through Wiegand Interface rarrnnnrnnnnrrnnrnnnnrranrvnannrnnrnnnnnranennnennnnennee 5 2 2 Connecting through RS 485 Interface rrnnrnnnrrnnnnnranrvnnrnranennnrrnnnrnnrnnasernennanennee 6 Fingerprint Only Mode
3. Once you lose the user card you cannot delete its related user from the reader 2 The new fingerprints enrolled will replace the existing enrolled fingerprints C GeoVision 4 2 Deletion Card data will be deleted from the reader and fingerprint templates will be erased from the user card Cards Required for Deletion e Manager Delete Card e User Card Deletion Procedures Step 1 In the standby mode the light is blue on Present the Manager Delete Card The light starts blinking red Step 2 With the light blinking red present the User Card The light starts blinking green Present the User Card again to delete all fingerprints stored in the card When the deletion is complete the light turns green and then steady blue 4 Card Fingerprint Mode 4 3 GeoFinger on Service After you connect the GeoFinger reader to the controller present the user card The light on the reader will start blinking blue Then scan your finger to gain access 1 Ifthe presented fingerprint matches any record in the card the light will turn from blue to green Access signal will be passed to the controller 2 If the presented fingerprint does NOT match the record in the card the light will turn from steady blue to blinking red with beeps for three times Then the light will come back to a steady blue The reader will not pass access signal to the controller 11 e GeoUision 5 Connecting an Alarm Device For
4. S compliant Ps WEEE Compliance This product is subject to the Waste Electrical and Electronic Equipment WEEE Directive and made compliant with the WEEE requirements e GeoUision Caution e GeoFinger is designed only for indoor usage Avoid exposing to sunshine or rains e To keep GeoFinger in good working condition it is recommended to have regular maintenance and physical cleaning of the reader a Introduction 1 Introduction The fingerprint reader GeoFinger can work with GV AS Controller and GV ASManager to create a complete access control system Depending on the model of the GeoFinger reader up to two types of operation modes are supported Card Fingerprint and Fingerprint Only Card Fingerprint Mode With the GeoFinger reader only you can enroll and manage users through the supplied Manager Enroll Card and Delete Card along with MIFARE user cards The fingerprint templates are stored in the user card The user gains access by scanning both his finger and his card The reader compares the presented finger to that of digital template stored in the card If the finger is successfully authenticated a signal is sent to momentarily activate the door relay of the controller Fingerprint Only Mode The fingerprints are enrolled through a GeoFinger 1901 reader installed on the computer running the GV ASManager software The fingerprint data are distributed through GV ASManager to the assigned GeoFinger readers installed
5. d Fingerprint Mode 4 1 Enrollment The user s fingerprints are stored in the user card and each user card can store up to 2 fingerprints The user must gain access by scanning both the user card and the finger Specifications e Have access by scanning both the user card and finger e Fingerprint templates are stored in the user card Cards Required for Enrollment e Manager Enroll Card e User Card Enrollment Procedures Step 1 In the standby mode the light is blue on Present the Manager Enroll Card The light starts blinking green Step 2 Present the User Card till the light blinks blue Or present the Manager Enroll Card to exit the enroll mode 4 Card Fingerprint Mode Step 3 With the light blinking blue scan your fingerprint till beep Withdraw your finger The light turns green and then blinks blue Step 4 Scan the same fingerprint again till beep and withdraw your finger The light again turns green and then blinks green Note It is required to scan the same fingerprint twice to complete the enrollment Step 5 Repeat Steps 3 and 4 to scan the second fingerprint if needed The same user card can store up to 2 fingerprints Step 6 Present the User Card to record fingerprints till beep The light turns green and then steady blue Then you can use the Card Plus Fingerprint on the GeoFinger reader Note 1 You will need the corresponding user card when deleting an individual user
6. e wire assignments of GeoFinger used for Wiegand connection Wire Red Black White Green Yellow Blue Orange Brown Silver Function 12v GND Data Datao NC NC NC NC NG For the wiring of extending distance it is recommended to use the standard RS 485 cable a twisted pair of 24 AWG wires The maximum distance of the Wiegand output cable should be restricted to a length of 30 meters 98 43 feet C GeoVision 2 2 Connecting through RS 485 Interface Only GeoFinger 1901 and GeoFinger 1902 readers support RS 485 connection Use the terminal block on the two reader models for RS 485 connection to the GV AS Controller GV AS Controller GeoFinger 1901 1902 The table below shows the pin assignments of GeoFinger used for RS 485 connection O EI Fingerprint Only Mode 3 Fingerprint Only Mode The Fingerprint Only mode must work with the GV ASManager software and the GeoFinger 1901 reader to enroll fingerprints Through GV ASManager the fingerprint data are distributed to GeoFinger 1901 1902 readers installed on GV AS Controllers Each GeoFinger reader can save up to 1 900 fingerprints for access control For detailed instructions see GV ASManager User s Manual GV HUB GV ASManager V2 1 or later GeoFinger 1901 to GV COM enroll fingerprints TCP IP RS 485 GV AS100 GV ASBox or GV AS400 GeoFinger 1901 1902 to verify fingerprints e GeoVision 4 Car
7. on GV AS Controllers for access control e GeoUision 1 1 Packing List If any of the items are missing or damaged contact your dealer to arrange a replacement e GeoFinger x 1 with a cable of 100 cm 3 28 feet e Manager Enroll Card x 1 e Manager Delete Card x 1 e Self Tapping Screw M3 x 6L x 2 e Self Tapping Screw M4 x 15L x 3 e Plastic Screw Anchor x 3 e Buzzer Hole Plate e Security Torx e User s Manual in CD The user card is an optional item It comes in two forms Card and Tag They look similar to the following examples You can find the serial number Fxxx xxxxx at the bottom right corner of the card or at the center of the tag F138 08572 Note Be sure that your user card has the serial number starting with the letter F otherwise you cannot record the fingerprints to the user card 2 Connecting to GV AS200 Controller 2 Connecting GV AS Controller Depending on the model of the GeoFinger reader two types of communication links are provided Wiegand and RS 485 2 1 Connecting through Wiegand Interface The GeoFinger is connected with an unshielded 9 wire cable of 100 cm 3 28 feet Connect these 4 unshielded wires to the assigned pins on the Wiegand interface of the GV AS Controller Red Black White and Green wires Roa Lg 2 12v Green PEJ ag White 42 o a cl pa Pa BZ Caper PIE GND Black GeoFinger GV AS Controller Wiegand Interface The table below shows th
8. the user of GeoFinger 1901 and GeoFinger 1902 you can connect one output device like sirens to the reader for warning when the access is granted The example below illustrates the connection of an output device to the GeoFinger reader Connect point on the output device to COM on the GeoFinger connect the points of the output device and the external power supply together and connect the point on the external power supply to NO or NC on the GeoFinger based on the state of the output device External Power GeoFinger 1901 1902 Specifications Specifications Indoor use only Wiegand 26 Wiegand 26 Wiegand 26 i RS 485 RS 485 Optical 12 x 16 mm 12 x 16 mm 17 x 20 mm 1 Port 1 Port 240V 2 5A 240V 2 5A Fingerprint Card Fingerprint Only Fingerprint Only Fingerprint Card Fingerprint Card 1 900 0 65C 32 149F 10 90 130 x 54 x 43 mm 130 x 54 x 38 mm 5 12 x 2 13 x 1 69 in 5 12 x 2 13 x 1 50 in 13 C GeoVision Ordering Information 81 MF 190 001 81 MF 191 001 81 MF 192 001 81 MA135 1F1 81 MK135 1F1 14