Home
Pool Pilot Jandy Interface
Contents
1. wire cable through the strain relief and connect it to the 4 position terminal block at the lower right of the Pool Pilot matching the colors to those already present see figure below 14 Tighten the strain relief 15 Re install the inner metal cover Be sure that cables are routed so that the cover does not pinch them 16 Plug 3 connectors into the display board on the cover 17 Re install the cover and tighten the 4 thumbscrews 18 Power can now be turned on again Aqualin 19 Power can now be turned on again k JANDY and Aqualink RS are registered trademarks of Waterpik Technologies Pool Pilot Step 13 4 Wire Terminal Block OSSSSS Step 13 4 Wire Cable Ground Lugs Sten 12 Install cable strain relief
2. 4 hour period has expired NOURWN Pool Pilot 5 The Pool Pilot will display Remote Boost and 100 for the purifier output setting while super chlorinating The Aqualink will run the pump continuously until the super chlorination boost cycle is complete Making the electrical connections Pool 1 Disconnect power Pilot Aqualin 2 Disconnect power k 3 Open the door and remove the inside panel from inside the Aqualink power center 4 Using 4 wire cable Jandy JDY 4278 or equivalent exterior grade 4 wire telephone cable connect to the red 4 pin connector at the top of the Aqualink circuit board 5 Observe the wire colors and match them to the colors marked on the circuit board and in the Aqualink manual 6 Run the cable through one of the knockouts at the lower left of the Aqualink power center 7 Replace the inside panel and close the door Pool 8 Loosen but do not remove the 4 thumbscrews on the side of the Pilot Pool Pilot cover 9 Carefully slide off the cover Carefully disconnect remove the 3 plugs that connect to the display board that is mounted inside the cover The display board does not need to be removed from the cover 10 Set the cover aside 11 Remove 4 screws that retain the inner metal Remove the inner metal cover 12 Remove one of the hole plugs at the bottom of the Pool Pilot and add a strain relief not supplied by Autopilot 13 Pass the 4
3. POOL PILOT DIGITAL Software Version 4 0 JANDY AQUALINK RS INTERFACE These instructions describe the installation and operation of the Pool Pilot Digital with a Jandy Aqualink RS They apply to all Pool Pilot Digital units with Version 4 0 software and Jandy Aqualink Version I or later software The Aqualink programming and messages are typical Please refer to your Aqualink user manual if problems are encountered programming on the Aqualink control panel Note The Aqualink may not display Pool Pilot menus or status unless the circulation pump is running Programming the Pool Pilot Digital to communicate with the Aqualink RS Pool 1 Press MENU Pilot 2 Press A or V until Installer Menu is displayed 3 Press and hold SELECT approximately 15 seconds until Installer Menu jumps to the top line of the display 4 Press A or V until Set pump control is displayed then press SELECT 5 Press A or V until Jandy runs pump is displayed then press SELECT 6 Press A or V until End menu mode is displayed then press SELECT 7 Remote Operation should now be on the display Programming the Pool Pilot to stop communicating with the Aqualink Aqualink 1 No action required on the Aqualink control panel Pool The Pool Pilot will display Remote Operation if is being controlled by Pilot the Aqualink To disconnect the Pool Pilot from the Aqualink for service 2 Press MENU 3 Pre
4. s MENU 3 Press FORWARD until the display shows SET Pool Pilot 4 When the Pool Pilot setting is displayed press ENTER to allow the purifier output to be adjusted 5 Press FORWARD or BACK until the desired purifier output percentage is shown The Aqualink will allow changes only in steps of 5 6 Press ENTER when done Pool 7 The Pool Pilot will display Remote Operation and the new xxx Pilot output setting Setting the Pool Pilot purifier to Super Chlorinate Boost operation from the Aqualink Control Panel Pool Pilot Aqualink The Pool Pilot will display Remote Operation if is being controlled by the Aqualink 1 Press MENU 2 Press FORWARD until the display shows SUPER CHLORINATE 3 Press ENTER and the display will show Start 4 Press ENTER to select the Start super chlorinate The Super Chlorinate can be stopped restarted or paused on the Aqualink panel Follow the following steps to modify the Super Chlorinate mode 1 Press MENU Press FORWARD until the display shows SUPER CHLORINATE Press ENTER and the display will show Pause Press FORWARD and the display will then show Restart Press FORWARD and the display will then show Stop Press FORWARD until the desired function is displayed Press ENTER to select the desired function Note Aqualink models prior to Rev K may terminate the Super chlorintate Boost mode before the full 2
5. ss A or V until Installer Menu is displayed 4 Press and hold SELECT approximately 15 seconds until Installer Menu jumps to the top line of the display 5 Press A or V until Set pump control is displayed then press SELECT 6 Press A or V until External Timer is displayed then press SELECT 7 Press A or V until End menu mode is displayed then press SELECT 8 The Pool Pilot display will now display Purifier xx followed by time etc The Pool Pilot will now ignore the Aqualink controller All settings for the Pool Pilot should now be programmed on the Pool Pilot not on the Aqualink control panel The Pool Pilot can now be programmed for automatic independent operation or service tests can be run Status Messages Pilot Aqualink In case of low salt loss of flow or a cell problem the Aqualink will periodically display CHECK Pool Pilot Pool While in Remote Operation the Pool Pilot will still display status or if a problem is detected display any error messages and light up the Check System red LED Adjusting the Pool Pilot purifier output from the Aqualink Control Panel Pool The Pool Pilot will display Remote Operation if is being controlled by Pilot the Aqualink Aqualink 1 The Aqualink control panel will periodically display the Pool Pilot output setting and the salt level 2 To adjust the Pool Pilot output pres